Technical Technical Product Specifications www.advp-deflecto.com Semi Rigid Flexible Metallic Duct with Crimped End UL Listed, Class O Air Duct Model No. A0UL0310C A0UL038C A0UL036C A0UL0410C A0UL048C A0UL046C A0UL0510C A0UL058C A0UL0610C A0UL068C A0UL0710C A0UL078C A0UL0810C A0UL088C A0UL1010C A0UL108C Description Semi Rigid Flex. Alum. Duct, Crimped Ends Semi Rigid Flex. Alum. Duct, Crimped Ends Semi Rigid Flex. Alum. Duct, Crimped Ends Semi Rigid Flex. Alum. Duct, Crimped Ends Semi Rigid Flex. Alum. Duct, Crimped Ends Semi Rigid Flex. Alum. Duct, Crimped Ends Semi Rigid Flex. Alum. Duct, Crimped Ends Semi Rigid Flex. Alum. Duct, Crimped Ends Semi Rigid Flex. Alum. Duct, Crimped Ends Semi Rigid Flex. Alum. Duct, Crimped Ends Semi Rigid Flex. Alum. Duct, Crimped Ends Semi Rigid Flex. Alum. Duct, Crimped Ends Semi Rigid Flex. Alum. Duct, Crimped Ends Semi Rigid Flex. Alum. Duct, Crimped Ends Semi Rigid Flex. Alum. Duct, Crimped Ends Semi Rigid Flex. Alum. Duct, Crimped End s Performance Data for uni nsulated aluminum flexible duc t Maximum Velocity • 5000 FPM / 25 m/sec • near zero permeability and leakage A0UL...C Maximum Rated Pressures • 3" - 10" dia., 12" w.c / 3 Kpa Pos/Neg Operating Temperature Range • -100°F to 430°F, -73°C to 221°C intermittent Pressure Loss Diagram Class O Air Duct, UL 181 Flame Spread/Smoke Developed VELOCITY FPM 10,000 4,0 00 00 3,0 • 0/0 00 2,0 5,000 4,000 General Information 3,000 18Ó 2,000 16Ó 14Ó 1,000 VOLUME CFM 700 INCHES TO DUCT DIAMETER 12Ó 10ÓÓ 9 8Ó 400 7Ó 300 6Ó 200 5Ó 1,0 100 00 900 700 500 600 50 40 800 70 400 30 300 20 .05 A (diameter) .1 .2 .3 .4 .5 .7 1.0 2 3 4 5 7 10 PRESSURE DROP (IN. W.G. PER 100 FT.) © 2001 DEFLECTO Canada Ltd. • St. Catharines, Ontario • Canada L2M 3Y2 • www.advp-deflecto.com DEFLECTO CORPORATION • P.O. Box 50057 • Indianapolis, IN 46250 • www.deflecto.com • flexes in any directions for easy installation • material description: common name - aluminum alloy • non-combustible • multiple use duct - our semi rigid flexible duct can be used for exhaust venting • will not sag between 6 foot supports • consult with your Authority Having Jurisdiction on the use of this product Model No. A AOUL0310C AOUL038C AOUL036C AOUL0410C AOUL048C AOUL046C AOUL0510C AOUL058C AOUL0610C AOUL068C AOUL0710C AOUL078C AOUL0810C AOUL088C AOUL1010C AOUL108C 3" dia. (7.6 cm) 3" dia. (7.6 cm) 3" dia. (7.6 cm) 4" dia. (10.2 cm) 4" dia. (10.2 cm) 4" dia. (10.2 cm) 5" dia. (12.7 cm) 5" dia. (12.7 cm) 6" dia. (15.2 cm) 6" dia. (15.2 cm) 7" dia. (17.7 cm) 7" dia. (17.7 cm) 8" dia. (20.3 cm) 8" dia. (20.3 cm) 10" dia. (25.4 cm) 10" dia. (25.4 cm) Deflecto's policy is one of continual product improvement in design and manufacturing wherever possible, therefore all specifications and designs are subject to change without notice and without incurring obligations. length 10 ft. (3 m) 8 ft. (2.4 m) 6 ft. (1.8 m) 10 ft. (3 m) 8 ft. (2.4 m) 6 ft. (1.8 m) 10 ft. (3 m) 8 ft. (2.4 m) 10 ft. (3 m) 8 ft. (2.4 m) 10 ft. (3 m) 8 ft. (2.4 m) 10 ft. (3 m) 8 ft. (2.4 m) 10 ft. (3 m) 8 ft. (2.4 m) 10.05 A0ULCtps Joint treatment 1 1/2” 1 1/2” Type A and B STEP 1: Apply mastic duct sealant (see notes) compound at least 11/2" on the inside of the uncrimped duct end and on the outside surface of the other crimped duct end. Crimp STEP 2: Push the 2 pieces of duct together and turn them until they are tight. This will bond the duct sealant compound. STEP 3: Seal the joint using 2 wraps of duct tape over the joint area (see notes). Duct Tape Type C Coupler STEP 1: Using a brush apply duct sealant compound (see notes) at least 11/2" on the inside of each duct end. Then push the ends together against the coupling center bead. 1 1/2” 1 1/2” STEP 2: Install 3 metal screws evenly spaced around the duct for ducts up to 8" (203mm) in diameter. Use 6 metal screws for duct over 8" (203mm) in diameter on each end of the duct. Duct Tape STEP3: Seal the joint using 2 wraps of duct tape over the joint area (see notes). Screws Type G 1 1/2” 1 1/2” STEP 1: Push the male galvanized connector into the female end of the other connector. STEP 2: Install 3 metal screws evenly spaced around the duct for ducts up to 8" (203mm) in diameter. Use 6 metal screws for duct over 8" (203mm) in diameter on each end of the duct. Duct Tape STEP 3: Seal the joint using 2 wraps of duct tape over the joint area (see notes). Staples Screws NOTES 1) Use Mastics listed and labelled to standard UL 181B and marked “181B-M” on containers. 2) Use tapes listed and labelled to standard UL 181B and marked “181B-FX”. 3) Non-metallic clamps shall be listed and labelled in accordance with standard UL 181B and marked “181B-C”. © 2010 Deflecto Corporation 10.03 JOINTINST