Technical Product Specifications

advertisement
Technical
Technical Product Specifications
www.advp-deflecto.com
Semi Rigid Flexible Metallic Duct with Crimped End UL Listed, Class O Air Duct
Model No.
A0UL0310C
A0UL038C
A0UL036C
A0UL0410C
A0UL048C
A0UL046C
A0UL0510C
A0UL058C
A0UL0610C
A0UL068C
A0UL0710C
A0UL078C
A0UL0810C
A0UL088C
A0UL1010C
A0UL108C
Description
Semi Rigid Flex. Alum. Duct, Crimped Ends
Semi Rigid Flex. Alum. Duct, Crimped Ends
Semi Rigid Flex. Alum. Duct, Crimped Ends
Semi Rigid Flex. Alum. Duct, Crimped Ends
Semi Rigid Flex. Alum. Duct, Crimped Ends
Semi Rigid Flex. Alum. Duct, Crimped Ends
Semi Rigid Flex. Alum. Duct, Crimped Ends
Semi Rigid Flex. Alum. Duct, Crimped Ends
Semi Rigid Flex. Alum. Duct, Crimped Ends
Semi Rigid Flex. Alum. Duct, Crimped Ends
Semi Rigid Flex. Alum. Duct, Crimped Ends
Semi Rigid Flex. Alum. Duct, Crimped Ends
Semi Rigid Flex. Alum. Duct, Crimped Ends
Semi Rigid Flex. Alum. Duct, Crimped Ends
Semi Rigid Flex. Alum. Duct, Crimped Ends
Semi Rigid Flex. Alum. Duct, Crimped End s
Performance Data
for uni nsulated aluminum flexible duc t
Maximum Velocity
• 5000 FPM / 25 m/sec
• near zero permeability and leakage
A0UL...C
Maximum Rated Pressures
• 3" - 10" dia., 12" w.c / 3 Kpa Pos/Neg
Operating Temperature Range
• -100°F to 430°F, -73°C to 221°C
intermittent
Pressure Loss Diagram
Class O Air Duct, UL 181
Flame Spread/Smoke Developed
VELOCITY FPM
10,000
4,0
00
00
3,0
• 0/0
00
2,0
5,000
4,000
General Information
3,000
18Ó
2,000
16Ó
14Ó
1,000
VOLUME CFM
700
INCHES TO DUCT DIAMETER
12Ó
10ÓÓ
9
8Ó
400
7Ó
300
6Ó
200
5Ó
1,0
100
00
900
700
500
600
50
40
800
70
400
30
300
20
.05
A
(diameter)
.1
.2
.3 .4 .5
.7
1.0
2
3
4
5
7 10
PRESSURE DROP
(IN. W.G. PER 100 FT.)
© 2001
DEFLECTO Canada Ltd. • St. Catharines, Ontario • Canada L2M 3Y2 • www.advp-deflecto.com
DEFLECTO CORPORATION • P.O. Box 50057 • Indianapolis, IN 46250 • www.deflecto.com
• flexes in any directions for easy installation
• material description:
common name - aluminum alloy
• non-combustible
• multiple use duct - our semi rigid flexible
duct can be used for exhaust venting
• will not sag between 6 foot supports
• consult with your Authority Having
Jurisdiction on the use of this product
Model No.
A
AOUL0310C
AOUL038C
AOUL036C
AOUL0410C
AOUL048C
AOUL046C
AOUL0510C
AOUL058C
AOUL0610C
AOUL068C
AOUL0710C
AOUL078C
AOUL0810C
AOUL088C
AOUL1010C
AOUL108C
3" dia. (7.6 cm)
3" dia. (7.6 cm)
3" dia. (7.6 cm)
4" dia. (10.2 cm)
4" dia. (10.2 cm)
4" dia. (10.2 cm)
5" dia. (12.7 cm)
5" dia. (12.7 cm)
6" dia. (15.2 cm)
6" dia. (15.2 cm)
7" dia. (17.7 cm)
7" dia. (17.7 cm)
8" dia. (20.3 cm)
8" dia. (20.3 cm)
10" dia. (25.4 cm)
10" dia. (25.4 cm)
Deflecto's policy is one of continual product improvement in design and manufacturing wherever possible,
therefore all specifications and designs are subject to change without notice and without incurring obligations.
length
10 ft. (3 m)
8 ft. (2.4 m)
6 ft. (1.8 m)
10 ft. (3 m)
8 ft. (2.4 m)
6 ft. (1.8 m)
10 ft. (3 m)
8 ft. (2.4 m)
10 ft. (3 m)
8 ft. (2.4 m)
10 ft. (3 m)
8 ft. (2.4 m)
10 ft. (3 m)
8 ft. (2.4 m)
10 ft. (3 m)
8 ft. (2.4 m)
10.05 A0ULCtps
Joint treatment
1 1/2”
1 1/2”
Type A and B
STEP 1: Apply mastic duct sealant (see notes) compound at
least 11/2" on the inside of the uncrimped duct end and on the
outside surface of the other crimped duct end.
Crimp
STEP 2: Push the 2 pieces of duct together and turn them
until they are tight. This will bond the duct sealant compound.
STEP 3: Seal the joint using 2 wraps of duct tape over the
joint area (see notes).
Duct Tape
Type C
Coupler
STEP 1: Using a brush apply duct sealant compound (see
notes) at least 11/2" on the inside of each duct end. Then
push the ends together against the coupling center bead.
1 1/2”
1 1/2”
STEP 2: Install 3 metal screws evenly spaced around the
duct for ducts up to 8" (203mm) in diameter. Use 6 metal
screws for duct over 8" (203mm) in diameter on each end
of the duct.
Duct Tape
STEP3: Seal the joint using 2 wraps of duct tape over the
joint area (see notes).
Screws
Type G
1 1/2”
1 1/2”
STEP 1: Push the male galvanized connector into the
female end of the other connector.
STEP 2: Install 3 metal screws evenly spaced around the
duct for ducts up to 8" (203mm) in diameter. Use 6 metal
screws for duct over 8" (203mm) in diameter on each end
of the duct.
Duct Tape
STEP 3: Seal the joint using 2 wraps of duct tape over
the joint area (see notes).
Staples
Screws
NOTES
1) Use Mastics listed and labelled to standard UL 181B and marked “181B-M” on containers.
2) Use tapes listed and labelled to standard UL 181B and marked “181B-FX”.
3) Non-metallic clamps shall be listed and labelled in accordance with standard UL 181B and marked “181B-C”.
© 2010 Deflecto Corporation
10.03 JOINTINST
Download