Electromechanical time switches ARVO Electromechanical time switch with daily programming by trippers for domestic use. 5 1 1 2 3 4 5 Trippers for the programming of activation time Switch for the choice of the operating mode Dial for time and minutes regulation Sealable cover Container: 3 DIN modules DIMENSIONS (mm) CONNECTION DIAGRAM Front view Side view 54 3 Diagram 60 44 88.5 16 A/250V~ 52 2 4 TIME MANAGEMENT TECHNICAL INFORMATION DAILY TIME SWITCHES GENERAL CHARACTERISTICS • • • Power supply Frequency Absorption Output relays capacity Operating precision Quadrant type Minimum intervention time: Intervention precision: Charge reserve Power supply: 230Vac (-15% ÷ +10%) Output relays capacity: 16(4) A / 250 Vac Operating mode: O always off A automatic (according to the set programming with the trippers) I always on • Charge reserve of 200 hours • daily programming • 24 hours quadrant with 96 trippers • every tripper covers 0,25 hours (15 minutes) Operating temperature Class of protection Degree of protection Container Code VP88250010 Model ARVO-D Description Daily electromechanical time switch V AC Hz W h 230 (- 15% ÷ +10%) 50 / 60 0.5 16(4) A / 250 Vac ± 1 second/day at 23°C 96 trippers 15 minutes ±5 minutes 200 (after charging ininterrupted for 120 h) -10 °C ÷ +50 °C II IP20 3 DIN module REFERENCE STANDARDS Compliance with Community Directives: 2006/95/EC (Low Voltage) and 2004/108/EC (E.M.C.) is declared with reference to the following Harmonized Standards:• EN 60730-2-7 TIME MANAGEMENT