■ EIC-E-1003-0 DIRECTIONAL CONTROLS Solenoid Controlled Pilot Operated Directional Valves These valves are composed of a solenoid operated pilot valves and a pilot operated slave valve. When a solenoid is energised the pilot valve directs the flow to move the spool of the slave valve, thus changing the direction of flow in the hydraulic circuit. High Pressure High Flow High pressure [315 Kgf/cm2] along with high flow means compact system design. a Solenoid Controlled Pilot Operated Directional Valves A B Lower pressure Drop System energy saving increased as pressure drop of each valve has greatly reduced. ■ E Graphic symbol b Y P T Specifications *1 Valve Type Model Numbers Max. Flow L/min Max. Min. *2 Max. Pilot Operating Required Pressure Pressure Pilot Pres. Kgf/cm2 2 Kgf/cm Kgf/cm2 Max. T-Line Back Pressure Kgf/cm2 Max. Changeover Frequency Cycles/min Ext. Drain Int. Drain AC DC Mass Kg R (S)-DSHG-04-3C※-※-50 (S)-DSHG-04-2N※-※-50 8.8 300 315 250 8 210 160 120 120 120 (S)-DSHG-04-2B※-※-50 Standard Type (S)-DSHG-06-2B※-※-51 Shockless Type 8.2 (S)-DSHG-06-3C※-※-51 (S)-DSHG-06-2N※-※-51 12.7 500 315 (S)-DSHG-06-3H※-※-51 (S)-DSHG-10-2B※-※-41 (S)-DSHG-10-3H※-※-41 250 210 (S)-DSHG-10-3C※-※-41 (S)-DSHG-10-2N※-※-41 8.8 8 210 160 10 250 1100 315 10 210 160 210 120 120 120 12.7 12.1 110 110 110 13.5 120 120 100 45.3 100 100 100 45.3 60 60 50 44.7 53.1 * 1. Maximum flow indicates a ceiling flow. As the ceiling flow depends on the type of spool and operating condition, refer to the list of Spool Functions on pages 4 to 6 for details. * 2. Pilot pressure of internal pilot drain models must always exceed tank line back pressure by a minimum required pilot pressure. Solenoid Controlled Pilot Operated Directional Valves 1 DIRECTIONAL CONTROLS ■ Number of Valve Positions Spool-Spring Arrangement 3 06 S: Shockless Type B: Spring Offset 2,4, 40,60, 10,12 (3,7) *1 C: Spring Centred 2,4, 40,60, 10,12 (3,5, 6 *17, 9,11) --- *2 C1: * With C1 With Choke A (Omit if not Required) C2: * With C2 A *2 B *2 With (Omit Choke if not Required) --- C1C2: * With C1&C2 Choke *2 10 N: NoSpring 2,4, 40 (3,7) *1 A (Omit (Omit if not if not Required) Required) B: Spring Offset 2,4, 40, (3,7) *1 A *2 B *2 (Omit if not Required) 2 -E T -R2* -D24 -N -51 -L Mod. With Alternate Offset Sol. Valve Size G: Subplate Mount -ing 2,4, 40,60, 10,12 (3,5, 6,*17, 9,11) 2,4, 40,6, 60,9, 12 (3,7) *1 -C2* Design Number Type of Mounting 2 A Type of Electrical Conduit Con. Series Number DSH: Solenoid Controlled Pilot Operated Directional Valve. F: For Phosphate Ester Type Fluids N: NoSpring 04 2 Coil Type Type 3 C: Spring Centred None: Standard Type B Spool Control Modification -2 Drain Connection -06 Pilot Connection G Models with Pilot Choke Valve DSH Special Two Position Valve S- Spool Type FSpecial Seals Model Number Designation R2: With Stroke AdjustNone: None: ment, InterExter- Both nal nal Ends Pilot Drain --AC A100, A 120 A2000, A240 RA: With Stroke DC AdjustDC12, ment D24 Port”A” D100 End T: E: InterExternal nal Drain Pilot RB: With Stroke Adjustment Port “B” End None: Terminal Box Type 50 L: (Omit if not Required) N: Plug-in Connector Type N1: Plug-in Con*3 nector with AC→ →DC indicaR110, tior R220 Light 51 --- 41 Note : 1. Options are marked with* 2. In spool type “3”,“5”,“6”,“60”and “7”, the combination applicable between pilot system & drain system is as described in the table below. Pilot connection Internal Pilot External Pilot (E) Drain Connection External Drain Internal Drain (T) External Drain Internal Drain (T) Care in Application Hold back pressure in the tank line so that the difference between pilot pressure and drain pressure is always more than minimum required pilot pressure Combination not available. No Limitation in use. *1 Shockless type (S-DSHG) are not available for spool type marked (). *2 Other spool types for special 2-position valves are available in addition to spool type 2, 3, 4, 40 and 7. [Refer to the column “valves with centre position and one offset position” (Special 2-position valve) on page 7 *3 Coil type “R” is not available for plug-in connector with Indicator type”N1". ■ Solenoid Ratings Solenoid ratings of pilot valve are identical with those of standard solenoid valve. Refer to relevant solenoid ratings described on the page below. Model Numbers (S-)DSHG-04 (S-)DSHG-06 (S-)DSHG-10 2 Pilot Valve Model Numbers ※※※-※-50 DSG-01- Solenoid Rating described on The page below EIC-E-1001 Page No.2 Solenoid Controlled Pilot Operated Directional Valves L: (Omit if not Required) DIRECTIONAL CONTROLS ■ Sub-plates Valve Model Numbers Sub-plate Model Numbers Thread Size Approx. Mass Kg DSHG-04 DHGM-04-2080 DHGM-04X-2080 1/2 BSP.F 3/4 BSP.F 4.4 4.1 DHGM-06-5080 DHGM-06X-5080 DHGM-10-4080 DHGM-10X-4080 3/4 BSP.F 1 BSP.F 1-1/4 BSP.F 1-1/2 BSP.F DSHG-06 DSHG-10 8.5 21.5 Sub-plates are available. Specify sub-plate model from the table above. When Sub-plates are not used, the mounting surface should have a good machined finish. Mounting Bolts Model Numbers Name DSHG-04 Soc. Hd. Cap. Screw DSHG-06 DSHG-10 Soc. Hd. Cap. Screw Soc. Hd. Cap. Screw ■ Mounting Bolt Qty. M6 x 40 Lg. 2 M10 x 45 Lg. M12 x 60 Lg. M20 x 75 Lg. 4 6 6 Mounting Bolt Ordering Code BKDSHG-04-50 BKDSHG-06-51 BKDSHG-10-41 E Options Models with Pilot Choke Adjustment (C1/C2/C1C2) Models with Pilot Stroke Adjustment (R2/RA/RB) “C1” Models --- By turning the adjusting screw clockwise, main spool changeover speed by the pilot pressure can be lowered. But centering speed of spring centered modes can not be changed. When the adjusting screw is screwed in, the main spool stroke becomes short and flow rate reduces. Graphic symbols (Ex. Spring Centered) “R2” Models “C2” Models --- When the adjusting screw is turned clockwise, main spool changeover speed can be lowered and centering speed of spring centered models can be also lowered. Solenoid Controlled Pilot Operated Directional Valves ■ AB a b Y PT “RA” Models AB a b Y Graphic symbols (Ex. Spring Centered) PT “RB” Models C2 Choke AB a a C1 Choke b Y Y P T A B b PT Additional Mass of Options Add mass of options described below to mass of standard type if options are used. C1,C2 C1C2 (S-)DSHG-04 0.65 1.3 Models With Stroke Adj. RA R2 RB 1.0 0.5 (S-)DSHG-06 0.65 1.3 1.2 0.6 (S-)DSHG-10 0.65 1.3 3.7 1.85 Model Numbers Models with Pilot Choke Adj. Solenoid Controlled Pilot Operated Directional Valves 3 DIRECTIONAL CONTROLS ■ List of Spool Functions (DSHG-04/S-DSHG-04) Three Positions Spring Centered Graphic Symbol Maximum Flow Spool Type A B a b L/min. P T Y 100 160 250 315 Kgf/cm² Kgf/cm² Kgf/cm² Kgf/cm² Model Numbers "2" "3" DSHG-04-3C2 300 300 200 145 S-DSHG-04-3C2 300 250 120 110 DSHG-04-3C3 300 300 300 300 DSHG-04-3C4 300 300 250 165 S-DSHG-04-3C4 300 300 140 110 DSHG-04-3C40 300 300 200 145 S-DSHG-04-3C40 300 250 120 110 "5" DSHG-04-3C5 250 250 245 245 "6" DSHG-04-3C6 300 260 245 235 300 300 300 300 "4" "40" DSHG-04-3C60 "60" S-DSHG-04-3C60 "7" DSHG-04-3C7 300 300 200 145 "9" DSHG-04-3C9 300 300 280 250 "10" "11" "12" DSHG-04-3C10 300 300 200 150 S-DSHG-04-3C10 300 250 120 110 DSHG-04-3C11 300 260 160 140 DSHG-04-3C12 300 280 170 135 S-DSHG-04-3C12 300 250 120 110 Two Positions No-Spring Graphic Symbol Spool Type A B a b Y P T Spring Offset Maximum Flow L/min. 100 160 250 315 Kgf/cm² Kgf/cm² Kgf/cm² Kgf/cm² Graphic Symbol A B b Y P T Maximum Flow L/min. 100 160 250 315 Kgf/cm² Kgf/cm² Kgf/cm² Kgf/cm² "2" (S-)DSHG-04-2N2 300 300 300 300 (S-)DSHG-04-2B2 300 300 300 300 "3" DSHG-04-2N3 300 300 300 300 DSHG-04-2B3 300 300 300 300 "4" (S-)DSHG-04-2N4 300 300 300 300 (S-)DSHG-04-2B4 300 300 300 300 "40" (S-)DSHG-04-2N40 300 300 300 300 (S-)DSHG-04-2B40 300 300 300 300 300 300 300 300 300 300 300 300 "7" DSHG-04-2N7 DSHG-04-2B7 Note: 1 Max. Flow described above shows value at pilot pressure more than 6 Kgf/cm2. 2 Max. Flow shows value at the condition of the flow as shown in right figure P→A→B→T (or P→B→A→T). Max. Flow differs according to hydraulic circuit, if port “A” or “B” is blocked. Consult Yuken for such application. 3 For values in the double row, upper is maximum flow at pilot pressure 5Kgf/cm2. (In case pressure centered model, pilot pressure is 5 Kgf/cm2), lower is pilot pressure of 7 Kgf/cm2. 4 Solenoid Controlled Pilot Operated Directional Valves A B P T a b DIRECTIONAL CONTROLS ■ List of Spool Functions (DSHG-06/S-DSHG-06) Three Positions Spring Centered A B a b Y P T "2" (S-)DSHG-06-3C2 500 500 "3" DSHG-06-3C3 500 500 "4" (S-)DSHG-06-3C4 500 500 (S-)DSHG-06-3C40 "40" 500 500 410 310 500 500 460 370 410 310 500 500 410 310 500 500 Graphic Symbol A B a b Y P T Maximum Flow L/min 100 160 250 315 Kgf/cm² Kgf/cm² Kgf/cm² Kgf/cm² (S-)DSHG-06-3H2 500 500 500 DSHG-06-3H3 500 500 500 (S-)DSHG-06-3H4 500 500 500 (S-)DSHG-06-3H40 500 500 500 "5" DSHG-06-3C5 500 500 425 350 DSHG-06-3H5 500 500 500 "6" DSHG-06-3C6 475 390 300 230 DSHG-06-3H6 500 500 500 475 420 340 280 500 500 500 (S-)DSHG-06-3C60 "60" (S-)DSHG-06-3H60 420 500 500 420 500 420 500 470 500 420 500 420 500 "7" DSHG-06-3C7 500 500 450 360 DSHG-06-3H7 500 500 500 500 "9" DSHG-06-3C9 500 500 450 500 360 500 DSHG-06-3H9 500 500 500 500 (S-)DSHG-06-3H10 500 500 500 DSHG-06-3H11 500 500 500 (S-)DSHG-06-3H12 500 500 500 "10" (S-)DSHG-06-3C10 500 500 "11" DSHG-06-3C11 500 500 (S-)DSHG-06-3C12 "12" 500 500 410 310 500 500 410 310 500 500 410 310 500 500 E 460 500 460 500 460 500 Two Positions No-Spring Graphic Symbol Spool Type A B a b Y P T Spring Offset Maximum Flow L/min 100 160 250 315 Kgf/cm² Kgf/cm² Kgf/cm² Kgf/cm² Maximum Flow L/min 100 160 250 315 Kgf/cm² Kgf/cm² Kgf/cm² Kgf/cm² Graphic Symbol A B b Y P T "2" (S-)DSHG-06-2N2 500 500 500 500 (S-)DSHG-06-2B2 500 500 500 500 "3" DSHG-06-2N3 500 500 500 500 DSHG-06-2B3 500 500 500 500 "4" (S-)DSHG-06-2N4 500 500 500 500 (S-)DSHG-06-2B4 500 500 500 500 "40" (S-)DSHG-06-2N40 500 500 500 500 (S-)DSHG-06-2B40 500 500 500 500 "7" DSHG-06-2N7 500 500 500 500 DSHG-06-2B7 500 500 500 500 Note: 1 Relation between max. flow and pilot pressure is: Value in the single column is constant regardless of pilot pressure subject to pilot pressure more than 8 Kgf/cm2. In case pressure centered models, pilot pressure is more than 10 Kgf/cm2. A B a 2 For values in the double row, upper is max. flow at pilot pressure 8 Kgf/cm . (In case pressure centered models, pilot pressure is 10 Kgf/cm2 or more.) Lower is pilot pressure of 15 Kgf/cm2. 2 Max. Flow shows value at the condition of the flow as shown in right figure P→A→B→T (or P→B→A→T). Max. Flow differs according to hydraulic circuit, if port “A” or “B” is blocked, consult Yuken for such application. Solenoid Controlled Pilot Operated Directional Valves b P T 5 Solenoid Controlled Pilot Operated Directional Valves Graphic Symbol Spool Type Pressure Centered Maximum Flow L/min 100 160 250 315 Kgf/cm² Kgf/cm² Kgf/cm² Kgf/cm² DIRECTIONAL CONTROLS ■ List of Spool Functions (DSHG-10/S-DSHG-10) Three Positions Spring Centered Graphic Symbol Spool Type A B a b Y P T Pressure Centered Maximum Flow L/min 100 160 250 315 Kgf/cm² Kgf/cm² Kgf/cm² Kgf/cm² "2" (S-)DSHG-10-3C2 1100 1100 "3" DSHG-10-3C3 1100 1100 "4" (S-)DSHG-10-3C4 1100 1100 "40" (S-)DSHG-10-3C40 1100 1100 950 750 1100 1100 1060 895 950 1100 950 750 1100 750 1100 1100 Graphic Symbol A B a b Y P T V Maximum Flow L/min 100 160 250 315 Kgf/cm² Kgf/cm² Kgf/cm² Kgf/cm² (S-)DSHG-10-3H2 1100 1100 1100 DSHG-10-3H3 1100 1100 1100 (S-)DSHG-10-3H4 1100 1100 1100 (S-)DSHG-10-3H40 1100 1100 1100 970 1100 1050 1100 970 1100 970 1100 1000 1100 970 1100 970 1100 "5" DSHG-10-3C5 1100 1100 980 850 DSHG-10-3H5 1100 1100 1100 "6" DSHG-06-3C6 1050 880 700 570 DSHG-10-3H6 1100 1100 1100 1050 940 785 680 1100 1100 1100 DSHG-10-3H7 1100 1100 1100 1100 DSHG-10-3H9 1100 1100 1100 1100 (S-)DSHG-10-3H10 1100 1100 1100 DSHG-10-3H11 1100 1100 1100 (S-)DSHG-10-3H12 1100 1100 1100 (S-)DSHG-10-3C60 "60" 870 "7" DSHG-10-3C7 1100 1100 1040 1100 1100 "9" DSHG-10-3C9 1100 1100 1040 870 950 1100 950 750 1100 750 1100 950 1100 750 1100 1100 "10" (S-)DSHG-10-3C10 1100 1100 "11" DSHG-10-3C11 1100 1100 "12" (S-)DSHG-10-3C12 1100 1100 (S-)DSHG-10-3H60 1060 1100 1060 1100 1060 1100 Two Positions No-Spring Graphic Symbol Spool Type A B a b Y P T Spring Offset Maximum Flow L/min 100 160 250 315 Kgf/cm² Kgf/cm² Kgf/cm² Kgf/cm² Graphic Symbol A B b Y P T Maximum Flow L/min 100 160 250 315 Kgf/cm² Kgf/cm² Kgf/cm² Kgf/cm² "2" (S-)DSHG-10-2N2 1100 1100 1100 1100 (S-)DSHG-10-2B2 1100 1100 1100 1100 "3" DSHG-10-2N3 1100 1100 1100 1100 DSHG-10-2B3 1100 1100 1100 1100 "4" (S-)DSHG-10-2N4 1100 1100 1100 1100 (S-)DSHG-10-2B4 1100 1100 1100 1100 "40" (S-)DSHG-10-2N40 1100 1100 1100 1100 (S-)DSHG-10-2B40 1100 1100 1100 1100 1100 1100 1100 1100 1100 1100 1100 1100 "7" DSHG-10-2N7 DSHG-10-2B7 Note : 1 Relation between max. flow and pilot pressure is Value in the single column is constant regardless of pilot pressure subject to pilot pressure more than 10 Kgf/cm2. 2 For values in the double row, upper is max. flow at pilot pressure 10 Kgf/cm . Lower is pilot pressure of 15 Kgf/cm2. 2 Max. Flow shows value at the condition of the flow as shown in right figure P→A→B→T (or P→B→A→T). Max. Flow differs according to hydraulic circuit, if port “A” or “B” is Blocked, consult Yuken for such application. 6 Solenoid Controlled Pilot Operated Directional Valves A B P T a b DIRECTIONAL CONTROLS ■ Spring Offset Valves with Alternate Solenoid Though our standard spring offset models use solenoid "b", alternate models using solenoid "a" are also available. The graphic symbols are expressed as below. For Models 2B -A and 2B B, refer to table as below. ※ ※ A B A B b Y a P T P T Standard Offset ■ Y Alternate Offset (“L”) Valve with Centre Position and One Offset Position (Special Two Position Valve) In addition to the standard two position valves as shown in the table on pages 4 to 6 two kinds of valves are available with center position and either one of two offset positions. Standard and alternate offset types use solenoid “b” and solenoid “a” respectively. (Example) In case of spool Type “2” Center Position Sol. a energised Sol. b energised A B b a Y A B P T P T b Y Graphic Symbols Standard Offset Type ※-DSHG-06-2B※A 04 10 P T T ※-DSHG-06-2B※B 04 A B P Y 10 ※-2B2A (S-)-DSHG- ※-2B3A DSHG- ※-2B4A (S-)DSHG- ※-2B40A (S-)DSHG- (S-)-DSHG- DSHG(S-)DSHG(S-)DSHG- ※-2B5A DSHG- DSHG- ※-2B6A DSHG- ※-2B60A Alternate Offset Type A B Model Numbers Y P T P T ※-DSHG-06-2N※A Y 10 DSHG- ※-2B9A DSHG- T ※ ※-2N4A ※-2B40B (S-)DSHG- ※-2N40A ※-2N5A (S-)DSHG- ※-2N6A ※-2N60A ※-2B7B DSHG- ※-2N7A ※-2B9B DSHG- ※-2N9A ※-2B10B (S-)DSHG- ※-2N10A DSHG- -2B11A DSHG- ※-2B11B DSHG- ※-2N11A ※-2B12A (S-)DSHG- ※-2B12B (S-)DSHG- ※-2N12A (S-)DSHG- P DSHG- -2N3A (S-)DSHG- (S-)DSHG- b Y ※-2N2A ※-2B4B ※-2B60B A B a (S-)-DSHG- DSHG- (S-)DSHG- Standard Offset Type 04 A B b a ※-2B6B DSHG- ※ Graphic Symbols DSHG- ※-2B7A ※-2B10A E ※-2B5B DSHG- (S-)DSHG- ※-2B2B ※-2B3B DSHG- (S-)DSHG- T Standard Offset Type Model Numbers b a Y P b Graphic Symbols Alternate Offset Type A B B "B" : (2B2B) "A" : (2B2A) Model Numbers A Solenoid Controlled Pilot Operated Directional Valves Y Solenoid Controlled Pilot Operated Directional Valves 7 DIRECTIONAL CONTROLS ■ Pressure Drop Pressure drop curves based on viscosity of 35cSt and specify gravity of 0.850. DSHG-04, S-DSHG-04 Pressure Drop ∆P Kgf/cm² 2 1 12 3 4 10 5 6 8 7 6 Pressure Drop Curve Numbers Pressure Drop Curve Numbers Spool Spool Type P→A B→T P→B A→T P→T Type P→A B→T P→B A→T P→T 5 (2) 4 (2) 5 (2) 6 (4) − 2 60 7 5 7 7 2 − 3 5 3 5 5 7 7 5 5 6 4 4 40 5 6 5 (2) 3 (3) 5 (2) 5 (5) 5 (2) 4 (4) 5 (2) 6 (6) − − 7 5 5 5 4 5 (6) 3 (4) 5 (6) 6 (7) 1 (2) 9 10 5 4 5 6 5 (2) 2 (2) 5 (2) 6 (4) − 11 12 6 5 6 4 5 (2) 4 (2) 5 (2) 5 (5) − − − 4 2 0 0 200 100 L/min 300 Note : Figures enclosed ( ) shows curve number for shockless type (S-DSHG-04). Flow Rate DSHG-06, S-DSHG-06 1 2 20 3 Pressure Drop ∆P Kgf/cm² 4 16 5 12 Spool Pressure Drop Curve N umbers Spool Pressure D rop Curve Numbers Type P→ A B→ T P→ B A→ T P→ T Type P→ A B→ T P→ B A → T P→ T 8 (6) 5 (1) 8 (6) 7 (2) − 5 (6) 5 (2) 6 (6) 7 ( 3) 3 ( 1) 60 2 6 7 8 8 3 4 0 0 100 200 300 400 500 L/min Flow Rate 4 40 5 6 7 6 4 6 8 (6) 5 (2) 8 (6) 7 (2) 6 7 6 4 6 7 − − 9 10 6 5 6 7 − 8 5 8 7 − 11 12 8 4 5 7 − 8 5 8 7 − 8 5 8 7 − 8 4 5 7 2 5 1 5 4 3 DSHG-10, S-DSHG-10 1 Kgf/cm² 2 Pressure Drop ∆P 20 3 4 16 5 12 6 7 8 8 4 9 0 0 200 400 600 800 1000 1100 Spool Pressure Drop Curve Numbers Spool Pressure Drop Curve Numbers Type P→A B→T P→B A→T P→T Type P→A B→T P→B A→T P→T 9 ( 8) 6 ( 3) 9 ( 8) 8 ( 4) − 2 60 8 ( 8 ) 5 ( 4 ) 8 ( 8 ) 5 ( 4 ) 3 ( 2 ) 3 7 6 7 7 5 7 7 6 7 7 − 4 9 ( 8) 6 ( 5) 9 ( 8) 6 ( 6) − 9 7 6 7 7 − 40 5 9 9 6 5 10 6 9 8 − 6 3 8 5 6 1 11 9 9 5 9 4 2 12 9 6 7 8 9 60 70 80 8 7 − 6 − − L/min Flow Rate For any other viscosity, multiply by the factors in the table right. For any other specific gravity (G'), the pressure drop ( P') may be obtained from the formula below. Viscosity cSt 15 Factor 20 30 40 50 0.81 0.87 0.96 1.03 1.09 1.14 1.19 1.23 1.27 1.30 P' = P (G'/0.850) 8 90 100 Solenoid Controlled Pilot Operated Directional Valves DIRECTIONAL CONTROLS ■ Typical Changeover Time Changeover time varies according to oil viscosity, spool type and hydraulic circuit. [Test Conditions] Coil Type : D(Models with DC Solenoids) Voltage : Rated Voltage Oil viscosity : 35cSt DSHG-06 DSHG-04 ms 150 SOL "ON" : 3C SOL "OFF" : 3C 100 2N SOL "ON" : 2B SOL "OFF" : 2B 50 0 50 100 150 200 250 150 Changeover Time Changeover Time ms Kgf/cm² SOL "ON" : 3C SOL "OFF" : 3C 100 SOL "ON" : 2B 50 SOL "OFF" : 2B 0 50 Pilot Pressure 100 150 200 250 Kgf/cm² Pilot Pressure DSHG-10 ms 200 E SOL "OFF" : 3C 150 SOL "ON" : 3C SOL "ON" & SOL "OFF" : 2B 2N 100 Solenoid Controlled Pilot Operated Directional Valves Changeover Time 250 50 0 50 100 150 200 250 Kgf/cm² Pilot Pressure Plug-in Connector Type: (S-) DSHG-04 11 Dia. x Thru. 17.5 Dia. Spotface 4 Places 204 101.6 Pressure Port "P" 50.4 34 34.9 69.8 72.9 91 UKEN - - N -50 DIMENSIONS IN MILLIMETRES Pilot Pressure Port "X" (For External Pilot Models only) Pilot Drain Port "Y" (For External Drain Models Only) * Position of cable departure can be changed. For details, refer to DSG-01 valves on EIC-E-1001-0 Page 10. Tank Port "T" 50 Cylinder Port "A" 7 Dia. x Thru. 11 Dia. Spotface 2 Places 210 97 Mounting Surface: ISO 4401-AD-07-4-A N1 1.5 Cylinder Port "B" Cable Departure* Cable Applicable: Outside Dia. ------ 8-10mm Conductor Area --- Not Exceeding 1.5mm² 56.5 27 Manual Actuator Nut 22 Hex. 35 116 64 Max. 39 192 Max. Mounting Surface (O-Ring Furnished) 53.4 4 ■ Solenoid Controlled Pilot Operated Directional Valves 3 Dia. Locating Pins 2 Places 9 DIRECTIONAL CONTROLS ■ Terminal Box Type : (S-)DSHG-04- - 210 90 -50 52 Space Needed to Remove Solenoid-Each End 60 48 163 181.3 Manual Actuator 6 Dia. 32 116 Nut 27 Hex. 53.4 Plug-in Connector Type : (S-)DSHG-0613.5 Dia. x Thru. 20 Dia. Spotface 6 Places 255 50.5 130.2 53.2 Tank Port "T" 92.1 46.1 210 DIMENSIONS IN MILLIMETRES Model Numbers ※※※-A※-N/N1 (S-)DSHG-06-※※※-D※-N/N1 (S-)DSHG-06-※※※-R※-N (S-)DSHG-06- Dimensions mm C D 53 57.2 216 34 Cylinder Port "B" Cylinder Port "A" Cable Departure Cable Applicable : Outside Dia. --- 8-10 mm Conductor Area --- Not Exceeding 1.5 mm² 56.5 C F 41 137 E Nut 22 Hex. 6 51.3 6 Dia. Two Locating Pins Position of cable departure can be changed. For details, refer to DSG-01 valve on EIC-E-1001 Page 10. 10 Solenoid Controlled Pilot Operated Directional Valves F 39 64 213 27.5 Manual Actuator 6 Dia. Mounting Surface (O-Ring Furnished) E 39 53 202 27.5 D 97 - N -51 N1 Pilot Drain Port "Y" (For External Drain Models Only) 13 156 Locating Pins 2 Places Pressure Port "P" 77 Pilot Pressure Port "X" (For External Pilot Models Only) - 118 Max. ■ 4 Mounting Surface (O-Ring Furnished) DIRECTIONAL CONTROLS ■ Terminal Box Type : (S-)DSHG-06- - -41 52 210 90 60 Space Needed to Remove Solenoid-Each End 48 Electrical conduit connection "C" Thd. (Both Ends) Manual Actuator 6 Sol a Sol b 184 202.3 Dia. x Thru. 6 41 137 Nut 22 51.3 Mounting surface (O-Ring furnished) Plug-in Connector Type : (S-)DSHG-1021.5 Dia. x Thru. 32 Dia. Spotface 6 Places Tank Port "T" DIMENSIONS IN MILLIMETRES E 43 79.4 158.8 43 114.3 233.8 19.6 Cylinder Port "A" Model Numbers ※※※-A※-N/N1 (S-)DSHG-10-※※※-D※-N/N1 (S-)DSHG-10-※※※-R※-N (S-)DSHG-10- 78 Dimensions mm C D E F 39 53 265 27.5 39 64 276 27.5 53 57.2 279 34 Cylinder Port "B" Pilot Pressure Port "X" (For External Pilot Model) 105 56.5 C Cable Departure Cable Applicable : Outside Dia. --- 8-10 mm Conductor Area --- Not Exceeding 1.5 mm² F Mounting Surface (O-Ring Furnished) 6 45 200 E D 97 198 Max. Pilot Drain Port "Y" (For External Drain Models Only) 76.2 21.8 - N -41 N1 Pressure Port "P" 384 190.5 77.5 - 6 Dia. Locating Pins Position of cable departure can be changed. For details, refer to DSG-01 valve on EIC-E-1001 Page 10. Solenoid Controlled Pilot Operated Directional Valves 11 Solenoid Controlled Pilot Operated Directional Valves ■ 6 Dia. Locating Pins 2 Places DIRECTIONAL CONTROLS ■ Terminal Box Type : (S-)DSHG-10210 90 60 - -41 52 Space Needed to Remove Solenoid-Each End 48 Electrical conduit connection "C" Thd. (Both Ends) Manual Actuator 6 M8 Thd. Two Eye Bolts Dia. x Thru. 6 45 200 247 265.3 Nut 22 28.5 Mounting surface (O-Ring furnished) 6 Dia. Locating Pins 2 Places DIMENSIONS IN MILLIMETRES OPTIONS 04 (S-)DSHG- 06 10 -C1/C2/C2- Models with Pilot Choke valve N N1 SOL a SOL b J LOCK H F E LOCK Dimension mm Model Numbers ※※※-C1 (S-)DSHG-04-※※※-C2 (S-)DSHG-04-※※※-C1C2 (S-)DSHG-06-※※※-C1 (S-)DSHG-06-※※※-C2 (S-)DSHG-06-※※※-C1C2 (S-)DSHG-10-※※※-C1 (S-)DSHG-10-※※※-C2 (S-)DSHG-10-※※※-C1C2 (S-)DSHG-04- 12 AC SOL J DC SOL R SOL 100 220 220 220 100 -- 220 220 220 185 140 100 260 260 260 177 -- 132 252 252 252 177 132 -- 252 252 252 217 172 132 292 292 292 240 -- 195 390 401 404 240 195 -- 315 315 315 280 235 195 355 355 355 E F H 145 -- 145 Solenoid Controlled Pilot Operated Directional Valves DIRECTIONAL CONTROLS OPTIONS 04 (S-)DSHG- 06 10 Models with Stroke Adjustment -R Fully Extended C SOL a SOL b Stroke Adj. Screw (Port "A" End ) 13 Hex. E Lock Nut 17 Hex. Fully Extended D E 288 94 33 376 111 40 558 164.5 65 Sub Plate DHGM- 04 -2080 04X Sub-plate Model Numbers DHGM-04-2080 1/2 BSP.F DHGM-04X-2080 3/4 BSP.F M10 Thd. x 17 Deep 4 Places 36 1 4 BSP.F Thd. 20 2 Places Y 46 T Y A A 58 6 Dia. 2 Places 14.2 65.8 88.1 130 3.6 Dia. x 5 Deep 2 Places 102 137.5 17.5 Dia. 4 Places M6 Thd. x 12 Deep 2 Places Valve Types Pilot Pressure Port “X” Port “Y” Solenoid Controlled Pilot Operated Directional Valves Used only on external pilot type valves. To be plugged on internal pilot type Valves. Used as drain port only on external drain type valves. To be plugged on internal pilot type Valves. Pilot Operated Directional Valves "C" Thd. 4 Places 90 76 P 125 65 57.1 90 120 96 71.4 69.8 55.9 14.2 11 Dia. x Thru. 17.5 Dia. Spotface 4 Places T “C” Thd. P 29 16 10.1 1.6 12 13.5 E DIMENSIONS IN MILLIMETRES 190 166 32.2 101.6 76.7 34 18.3 12 Stroke Adjustment Screw (Port "B" End ) 13 Hex. Spring Centered No-Spring Used as pilot port Used Spring offset Manually Operated Direction Valves Remarks Used as pilot drain port Not used (plug is not required) Normal size: Only 04 Used as drain port Solenoid Controlled Pilot Operated Directional Valves 13 Solenoid Controlled Pilot Operated Directional Valves D 33 ※※※-R2 (S-)DSHG-06-※※※-R2 (S-)DSHG-10-※※※-R2 (S-)DSHG-04- C 21.5 Model Numbers DIRECTIONAL CONTROLS 06 DHGM-2080 06X F J P 12 8.9 W B 156 Sub-plate Model Numbers “C” Thd. DHGM-06-5080 DHGM-06X-5080 ¾ BSP.F 1 BSP.F B A X N 11 Dia. 4 Places 24.5 Dia. 4 Places 12.5 V 73.1 17.5 A X T P Y W 11.9 116 134 110 92.1 Y T V H 19.1 46.1 74.6 204 180 130.2 12 25 D E 1/4 BSP.F Thd. 4 Places M12 Thd. x 24 Deep 6 Places 50 35 L "C" Thd. 4 Places K Dimensions mm D E F H J K L N 151.2 155.2 137.7 148 102 106 54.4 50 30.6 25 125.8 130 78.2 74 42.5 32 For uses of Port “X”, “Y”, “V”, “W”, refer to DHGM-10- ※ DIMENSIONS IN MILLIMETRES DHGM20 10 -4080 10X 306.5 266.5 38 190.5 168.3 147.6 114.3 76.2 41.3 7 Dia. x 8 Deep 2 Places M20 Thd. x 34 Deep 6 Places 213 60 45 F 20.1 14 21.8 11 Dia. 4 Places X W 114.3 T P A B W Y T P V B A X 35 199 158.8 123.8 79.4 28.6 Y V 82.5 17.5 Dia. x Thru. 26 Dia. Spotface 4 Places 234 36 Dia. 4 Places Sub-plate Model Numbers “C” Thd. DHGM-10-4080 DHGM-10X-4080 1-1/4 BSP.F 1-1/2 BSP.F "C" Thd. 4 Places H 17 K J Dimensions mm F H J K 152 156 79 74 185.5 194.5 120.5 112.5 Solenoid Controlled Pilot Operated Directional Valves 3/8 BSP.F Thd. 4 Places DIRECTIONAL CONTROLS Note : Uses of port “X”, “Y”, “V” and “W” Valve Types Pilot Pres. Port “X” Port “Y” Used only on Used as drain port only on external drain type external pilot type valves. valves. Solenoid Controlled Pilot Spring centered, No-spring, Operated Spring offset To be plugged on Directional internal pilot type Valves valves. Pilot Spring centered, No-spring, Operated Used Directional Spring offset Valves Manually Operated Directional Valves Port “V” Port “W” Not used (plug is not required) To be plugged on * internal pilot type valves. Used as pilot pres. Port Not used (plug is not required) Used pilot port drain port Not used Not used (plug is not required) (plug is not required) Not used (plug is not required) Used * As the thread is provided on the body, plug either port on the sub-plate or port on the body. List of Pilot Valves Valve Model Numbers Pilot Valve Model Numbers ※ ★-▲ (S-)DSHG-04/06/10-2B※-★-▲ (S-)DSHG-04/06/10-2N※-★-▲ (S-)DSHG-04/06/10-3C - ■ ★-▲-50 DSG-01-2B2-★-▲-50-L DSG-01-2D2-★-▲-50 DSG-01-3C4- Notes: 1 Fill coil type (a symbol representing current/ Likewise, in voltage) in section marked selection marked ▲, fill a symbol representing the type of conduit connection (N: Plug-in connector type). 2 For the details of the pilot valves, see page EIC-E-1001 Page: 2. ★. Spare Parts List List of Seals Part Numbers Sl. No. Name of Part DSHG-04 1 2 3 4 5 6 7 8 9 10 O-Ring O-Ring O-Ring O-Ring O-Ring O-Ring O-Ring O-Ring O-Ring O-Ring SO-NB-P9 ----SO-NB-P34 ---SO-NB-P22A DSHG-06 DSHG-10 --SO-NB-P9 -SO-NB-P14 -SO-NB-P20 SO-NB-P30 ---SO-NB-P40 --SO-NB-P42 -SO-NB-G65 --- Qty 4 2 2 2 4 2 2 4 2 4 Note: When ordering the seals, please specify the Seal Kit number from the table below. List of Seal kits Valve Model Numbers Seal Kit Numbers DSHG-04 DSHG-06 DSHG-10 KS-DSHG-04-50 KS-DSHG-06-51 KS-DSHG-10-41 Note: When ordering the seals, please specify the Seal Kit number KS-DSHG-04-50/KS-DSHG-06-51/ KS-DSHG-10-41. Solenoid Controlled Pilot Operated Directional Valves 15 E Solenoid Controlled Pilot Operated Directional Valves ■