ArrowLink™ Modular Wiring Devices

advertisement
ArrowLink Modular
Wiring Devices
™
Devices which make installation faster,
easier, more consistent and more
cost effective.
ArrowLink™ Modular Wiring Devices
The most complete device
installation solution.
ArrowLink™ Modular Wiring Devices change the game for
electrical installers by providing an unequalled breadth of
devices that offer greater speed and consistency to lower
installation costs on the job site.
Modular Wiring Devices
Table of Contents
ArrowLink Features . . . . . . . . . . . . . . . 4
The ArrowLink Advantage . . . . . . . . . . 6
Straight Blade Receptacles . . . . . . . . 10
Hospital Grade Receptacles . . . . . . . 15
GFCIs . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Isolated Ground Receptacles . . . . . . 21
TVSS Receptacles . . . . . . . . . . . . . . . 23
Switches . . . . . . . . . . . . . . . . . . . . . . . 25
ArrowLink maximizes labor savings:
• Breadth of line provides efficiency
in more applications
• Modular connections increase
trim-out speed more than 2 to 1
• Consistent connections eliminate
mis-wiring and reduce call-backs
• Connector leads are prepped,
stripped and ready to wire
• External connections provide job
site flexibility
• Reduces number of trim-out
installers required
• Narrows learning curve for
apprentice labor
ArrowLink Receptacle Modular Plug & Connector
2
Modular Decorator &
Toggle Switches
Modular TVSS
Receptacles
The benefits of modular
devices for your entire
job, not just a portion.
Modular Straight Blade Single &
Duplex Receptacles
Why limit yourself to general use duplex, isolated ground,
and GFCI receptacles? ArrowLink™ Modular Wiring
Devices also provide you switches, single receptacles
and TVSS devices!
Modular GFCIs,
Tamper Resistant GFCIs
Modular Isolated Ground
Receptacles
3
ArrowLink™ Features
The ArrowLink™
Advantage
ArrowLink is designed to help you complete a job quickly
and cost effectively. The breadth of line combined with
unique installation flexibility and safety features provide
a complete job solution.
Modular Receptacle
Leaded
ArrowLink plug
preserves the
structural
integrity of the
base wiring
device
Plug and
connector
design provides
first make/last
break grounding
connection
One-piece
impact-resistant
connector for
maximum
durability during
rough-in
Polybag
connector
cover shields
contacts from
paint and
drywall mud
4
Plug leads
#12 AWG
stranded
copper
Terminal safety
barriers provide
insulation from
conductive
surfaces
Connector
leads #12
AWG, available
in solid or
stranded
copper
Audible click
indicates a
secure
connection
Slim profile
and vertical
wire orientation
of device and
connector
assures ease
of installation
Quality, Dependability
and Versatility
Patent-pending ArrowLink™ modular plugs and connectors
provide high quality circuit connections while reducing
overall installation time.
Modular Switch
Pre-wired
modular
switches
available in
both toggle
and decorator
styles for 120V
or 277V
Save time - no
more taping
terminals
ArrowLink
allows easy
change-out
for device
maintenance
Clearly marked,
consistent
pre-wired
configurations
eliminate
mis-wiring
of devices
Pre-stripped
wire leads for
quicker
connections
during rough-in
Unique switch
and receptacle
configurations
will not
inter-mate for
added safety
ArrowLink
wiring devices
can easily be
converted for
standard
installation
#12 AWG wire
leads color
coded for
your 277V
applications;
see page 25
for 277V
conductor
color options
5
The ArrowLink™ Advantage
ArrowLink’s™ broad product offering plus the unique flexibility
of an external connection style saves you time and labor no
matter where the job takes you.
Consistent installation
for any job.
ArrowLink works where you work . . .
Healthcare Facilities
• Hospitals
Commercial & Retail
Environments
Educational Institutions
• Schools & academies
• Medical offices
• Offices
• Colleges & universities
• Urgent care clinics
• Shopping malls & big box retail
• Nursing homes
• Resort & conference centers
• Vocational & technical
learning centers
• Outpatient facilities
• Casinos
• Institutes
• Rehabilitation facilities
• Restaurants
• Conservatories
. . . and makes installation a snap.
Step 1
Step 2
Step 3
At rough-in, connect the pre-stripped
leads of the ArrowLink connector to
the building wire and push the
protected connection back into the
box until trim-out.
At trim-out, simply snap the
ArrowLink device onto the
pre-wired connector in the box.
Mount the device into the box,
install the cover plate and finish
the job on time.
6
ArrowLink™ staging lets
you set the schedule.
Let us handle the staging for you – simply place your entire
order prior to rough-in. We’ll ship you the connectors
immediately and ship the devices on whatever date you specify.
You can stage your job . . .
ABC Wholesale Electric
345 Main Street
Anytown, MN 30000
(777) 555-4567
Two (2) Purchase Orders:
• Order your ArrowLink connectors at rough-in for
immediate shipment
• Order your ArrowLink devices at trim-out based on
these shipment lead times:
- Less than 500 devices lead time: 3-5 business days
* Add 2 days for initial orders of color coded switches
SEE BELOW
SHIP TO:
MegaVolt Electric
2000 1st Street
Sometown, MN 30001
TO:
Cooper Wiring Devices
203 Cooper Circle
Peachtree City, GA 30269
Vendor
12345
Cust. #
2468
Line # Qty Ord
. . . or allow us to do it for you.
Place only one (1) Purchase Order today:
• ArrowLink connectors ship immediately
• ArrowLink devices ship on the day you specify
Order Date: 3/2/09
Date Due:
- 500-2,000 devices lead time: 5-10 business days
- Over 2,000 devices: consult factory for shipping lead time
PURCHASE
ORDER
20995601-MV
1
2
3
4
5
6
7
8
320
60
20
20
20
40
420
60
NOTE:
• Change orders are also simple – you can change
the device order up to one (1) week prior to shipping
without affecting the ship date.*
Ref. #
MV
Item / SKU #
CR5362WM
AH1221WM
5361WM
5362WSM
IG5362WM
VGF20WM
MCR125SOL
MCS120SOL
FOB Point
Destination
Ship Via
Pre-Paid
Term
2%
Description
20A 125V Modular Duplex Recept
20A 120V Modular Toggle Switch
20A 125V Modular Single Recept
Recept
20A 125V Modular Duplex TVSS
pt
20A 125V Modular Duplex IG Rece
Recept
20A 125V Modular Duplex GFCI
Solid
ArrowLink Receptacle Connector
ArrowLink Switch Connector Solid
Ship Lines 7 & 8 immediately
09
Ship Lines 1, 2, 3 & 6 March 16,
Ship Lines 4 & 5 March 23, 09
*Changes less than a week prior to shipping may effect
lead time
Devices that arrive the way you want!
ArrowLink features bulk packaging designed with the contractor in mind.
• All devices are shipped in convenient recyclable bulk pack cartons
• All packaging made of 100% recycled material
• Packaging sized for easy room-to-room transport
• No inner packaging speeds installation, eliminates waste, and reduces
clean-up at the end of the job
• Incorporated “honeycomb” dividers allow a consistent package size across
our entire ArrowLink product line for efficient shipping
7
ArrowLink™ Modular Wiring Devices
Go modular, increase
efficiency and stay
code compliant.
ArrowLink™ modular devices are great at saving labor
time and costs while not affecting conductor volume
when calculating box fill.
See the labor savings for yourself!
Compare the bottom line, based on 1,000 installed devices and a modest labor rate of $50.00/hour:
Conventional
Installation Step,
5362W Receptacle
Device
Labor time,
% of 1 hr
0.0900 hr
Labor cost
(@ $50/hr)
ArrowLink Modular
Installation Step,
5362WM Receptacle
$4.50
Device
Labor time,
% of 1 hr
Labor cost
(@ $50/hr)
0.0375 hr
$1.88
Wire (Pig Tails)
0.0200 hr
$1.00
ArrowLink Connector
0.0100 hr
$0.50
Connectors
0.0100 hr
$0.50
Connectors
0.0100 hr
$0.50
Mud Ring
0.0150 hr
$0.75
Mud Ring
0.0150 hr
$0.75
Box
0.0500 hr
$2.50
Box
0.0500 hr
$2.50
Plate
0.0150 hr
$0.75
Plate
0.0150 hr
$0.75
Shim
0.0200 hr
$1.00
Shim
0.0200 hr
$1.00
Individual Total
0.2200 hr
$11.00
Individual Total
0.1575 hr
$7.88
157.50 hrs
$7,875.00
x 1,000 openings 220.00 hrs $11,000.00
x 1,000 openings
ArrowLink
Labor Savings
Per Opening
$3.13
ArrowLink
Total Project
Labor Savings
$3,125.00
Device install rate assumes ArrowLink at 2.5 to 1 over conventional devices
Box Fill Calculations for ArrowLink Devices
When using ArrowLink, simply calculate box fill as
normal – plugs and connectors, like wirenuts, are
not counted.
Chart 1
(2) 12 AWG
(2) 12 AWG
Conductor volume example based on Chart 1:
Switch line & load conductors (1 ea). . . . . . . . . . . . 2
Switch
Connector
Receptacle
Connector
Receptacle hot & neutral conductors (1 ea) . . . . . . 2
All equipment grounding conductors count
as a single conductor volume . . . . . . . . . . . . . . . . . 1
Each single gang device yoke counts as
two (2 ea) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Wire connectors and pigtails do not count
as conductor volume . . . . . . . . . . . . . . . . . . . . . . . . 0
1 Strap/Yoke=
(2) 12AWG
2 Ground Wires=
(1) 12 AWG
1 Strap/Yoke=
(2) 12AWG
Total Conductor Volume . . . . . . . . . . . . . . . . . . . . . 9
* Calculate volume for your application using formulas found in
NEC® section 314.16
** Box volume in Chart 1 based on 4" square x 2 1/2" box =
30.3 in.3
8
Connectors are
not counted
toward box fill
Box Fill:
(9) 12AWG Conductors
9 x 2.25 = 20.25 in3
Finish your installation with
the right wallplates.
Available in multiple configurations, our wallplates meet NEC
requirements for use in commercial, industrial and institutional
areas. Stringent material specifications ensure wallplates that
deliver strength and fire resistance.
302/304 Stainless
Steel
Thermoplastic:
Polycarbonate and Nylon
Designed, tested and
manufactured to
deliver top
performance in
demanding
environments.
Virtually unbreakable with an easy-toclean finish and exclusive time-saving
Screw-Catch™ feature that holds
mounting screws captive to
simplify installation.
Stainless
Steel
PJS Series
• Superior non-corrosive and
nonmagnetic properties for
applications needing added
protection.
• Stainless steel alloy contains 18%
chromium and 8% nickel for
corrosion resistance.
• Stamped from 0.032" (0.81mm)
thick material.
• Horizontally satin-brushed surface
finish resists fingerprints.
Thermoplastic
• 302/304 Stainless Steel Wallplates
• Nylon wallplates
have a flush-fitting,
warp-resistant
design.
• Rugged
construction for
less breakage and
more resistance
to bowing.
• Polycarbonate
wallplates have high
structural rigidity,
long-term form
retention, plus
superior impact and
abrasion resistance.
• High gloss finish is
soil resistant and
easy to clean.
• Matching stainless steel mounting
screws provided.
Wallplates at a Glance
• Screwless
polycarbonate
wallplates (PJS
series) have a clean,
streamlined look
that can change out
to a different color
in seconds.
Size/Type
Stainless Steel
I 93000 - 93600
Series
---
Material
Polycarbonate
---
Standard Size
• Thermoplastic Nylon Wallplates
Standard Size
Extra Depth
Pre-Marked Special I EM93000, IG93000
Use, Standard Size
& IG97000 Series
Mid-Size
I 93900 Series
• Standard, Mid-Size and Oversize
• Combination Configurations
• Matching mounting
screws provided.
Specification Box
• Thermoplastic Polycarbonate Wallplates
• 1-Gang to 6-Gang
• Nylon wallplates are
chemically resistant
to cleaning agents
and solvents.
• Coax/Telephone Configurations
Pre-Marked Special --Use, Mid-Size
• Pre-marked Special Use Wallplates
Oversize
I 93800 Series
----I PJ Series
I PJS Series
I PJ-EM, PJ-CO,
PJ-GF & PJ-IG
Series
---
Nylon
I 5100 Series
--I EM5100 &
IG5100 Series
-----
---
9
Modular Receptacles
Project Name:
Prepared By:
Project Number:
Date:
Catalog Number:
Type:
Straight Blade Receptacles
1.32"
(33.5mm)
Industrial Grade Duplex & Single Receptacles
4.19"
(106.4mm)
3.28"
(83.3mm)
Depth with
ArrowLink
1.36"
(34.5mm)
5362_M
3.28"
(83.3mm)
1.98"
(50.3mm)
2.38"
(60.3mm)
2-Pole, 3-Wire Grounding
15A 125V, 15A 250V
20A 125V, 20A 250V
FEATURES
• ArrowLink modular plug and connector provide
high quality circuit connections and incorporate a
first make/last break grounding design.
• Wire leads are crimped and resistance welded to
plug and connector terminals for maximum
durability.
• Audible “click” when mating plug and connector
indicates proper assembly during final device
installation.
• Pre-wired plugs provide 100% inspected and
consistent torque settings for reliable connections
to base devices.
• Connectors shipped with re-usable protective
covering that allows circuit testing while
protecting the connection from foreign matter.
• Exclusive screw terminal guards provide a
protective barrier from conductive surfaces.
• Exclusive 5-leaf solid brass line contacts ensure
lowest heat rise, smooth plug blade insertion,
long-term retention.
• Rigid, glass reinforced nylon base lends ultimate
strength and superior high heat resistance in
contact carrier.
• High impact and chemical-resistant nylon face.
• 0.050" (1.27mm) solid brass mounting strap with
non-riveted, integral one-piece grounding system
for highest durability – assures superior ground
integrity under heaviest use.
• Long, broad mounting strap helps reach large panel
cutouts for code compliance.
• Screw-Catch™ feature on duplex devices speeds
mounting of wallplates.
Depth with
ArrowLink
1.41"
(35.8mm)
5261_M
Back Wire and Side Wire – 1 Piece Brass Ground System
1.42"
(36.1mm)
Lead
Length:
6.00”
(152.4mm)
0.40"
(10.2mm)
1.08"
(27.4mm)
Receptacle
Connector
Catalog No.
F
R
S
426
Rating
A V
15 125
NEMA
5-15R
Description
Duplex Modular Receptacle
Single Modular Receptacle
I 5262___M
I 5261___M
Available
Colors
B, BK, GY, RD, V, W
B, GY, V, W
15 250
6-15R
Duplex Modular Receptacle
I 5662___M
B, V, W
20 125
5-20R
Duplex Modular Receptacle
Single Modular Receptacle
20 250
6-20R
Duplex Modular Receptacle
I 5362___M
I 5361___M
B, BK, GY, LA, RD, V, W
B, BK, GY, RD, V, W
I 5462___M
B, GY, V, W
For ordering, include Cat. No. followed by the color code: B (Brown), BK (Black), GY (Gray), LA (Light Almond), RD (Red), V
(Ivory), W (White)
1.42"
(36.1mm)
0.40"
(10.2mm)
1.08"
(27.4mm)
ArrowLink Receptacle Connectors
Receptacle
Plug
G
5-15R
W
G
W
5-20R
Description
G
6-15R
G
G
6-20R
For Specification & Performance
Data, see page 13.
C
R
US
Catalog No.
ArrowLink Modular Receptacle 125V Building Wire Connector, Solid Wire
I MCR125SOL
ArrowLink Modular Receptacle 125V Building Wire Connector, Stranded Wire
I MCR125STR
ArrowLink Modular Receptacle 250V Building Wire Connector, Solid Wire
I MCR250SOL
ArrowLink Modular Receptacle 250V Building Wire Connector, Stranded Wire
I MCR250STR
Patent Pending
TESTING & CODE COMPLIANCE
MATERIAL CHARACTERISTICS
• Base Device: UL Listed to UL498, file no. E15058; UL verified
to Federal Spec. WS-596G; CSA Certified to C22.2, no. 42,
file no. 6914, class 6233-01; NOM Certified
• ArrowLink: Plug & connector cULus Listed to UL2459 file no.
E325188
• Combined: cULus Listed wiring assembly, UL file no. E326691
• Nylon with PVC terminal guards, except single: adhesive terminal barrier
• Environmental, Base Device: Flammability meets UL 94 requirements; V2 rated; temperature
rating: -20ºC to 70ºC (-4ºF to 158ºF), except single: -20ºC to 60ºC (-4ºF to 140ºF)
• Environmental, ArrowLink: Flammability meets UL 94 requirements; V2 rated; temperature
rating: -20ºC to 90ºC (-4ºF to 194ºF) max.
10
Modular Receptacles
Project Name:
Prepared By:
Project Number:
Date:
Catalog Number:
Type:
Straight Blade Receptacles
2-Pole, 3-Wire Grounding
15A 125V
20A 125V
1.30"
(33.0mm)
Industrial Grade Duplex & Single Receptacles
FEATURES
• ArrowLink modular plug and connector provide
high quality circuit connections and incorporate a
first make/last break grounding design.
• Wire leads are crimped and resistance welded
to plug and connector terminals for maximum
durability.
• Audible “click” when mating plug and connector
indicates proper assembly during final device
installation.
• Pre-wired plugs provide 100% inspected and
consistent torque settings for reliable connections
to base devices.
• Connectors shipped with re-usable protective
covering that allows circuit testing while
protecting the connection from foreign matter.
• Exclusive screw terminal guards provide a
protective barrier from conductive surfaces.
• Exclusive 5-leaf solid brass line contacts ensure
lowest heat rise, smooth plug blade insertion,
long-term retention.
• Rigid, glass reinforced nylon base lends ultimate
strength and superior high heat resistance in
contact carrier.
• High impact and chemical-resistant nylon face.
• Exclusive 0.030" (0.76mm) solid brass, non-riveted,
integral one-piece grounding shunt system assures
ground integrity.
• Long, broad mounting strap helps reach large panel
cutouts for code compliance.
• Screw-Catch™ feature on traditional style duplex
devices speeds mounting of wallplates.
NEMA
5-15R
Description
Duplex Modular Receptacle
Decorator Duplex Modular Receptacle
20 125
5-20R
Duplex Modular Receptacle
Decorator Duplex Modular Receptacle
3.28"
(83.3mm)
Depth with
ArrowLink
1.36"
(34.5mm)
5352_M
1.32"
(33.5mm)
4.19"
(106.4mm)
3.28"
(83.3mm)
Back Wire and Side Wire – Brass Ground Shunt
Rating
A V
15 125
4.19"
(106.4mm)
F
R
S
426
6262_M
Catalog No. Available
Colors
I 5252___M A, B, BK, BL, GY, LA, RD, V, W
I 6262___M B, BK, GY, LA, RD, V, W
I 5352___M
I 6362___M
A, B, BK, BL, GY, LA, RD, V, W
A, B, BK, GY, LA, RD, V, W
For ordering, include Cat. No. followed by the color code: A (Almond), B (Brown), BK (Black), BL (Blue), GY (Gray), LA (Light
Almond), RD (Red), V (Ivory), W (White)
Depth with
ArrowLink
1.31"
(33.2mm)
1.42"
(36.1mm)
Lead
Length:
6.00”
(152.4mm)
0.40"
(10.2mm)
1.08"
(27.4mm)
Receptacle
Connector
1.42"
(36.1mm)
0.40"
(10.2mm)
ArrowLink Receptacle Connectors
C
Description
Catalog No.
ArrowLink Modular Receptacle 125V Building Wire Connector, Solid Wire
I MCR125SOL
ArrowLink Modular Receptacle 125V Building Wire Connector, Stranded Wire
I MCR125STR
R
US
1.08"
(27.4mm)
Receptacle
Plug
G
Patent Pending
5-15R
W
G
W
5-20R
For Specification & Performance
Data, see page 14.
TESTING & CODE COMPLIANCE
MATERIAL CHARACTERISTICS
• Base Device: UL Listed to UL498, file no. E15058; UL verified to
Federal Spec. WS-596G; CSA Certified to C22.2, no. 42, file no.
6914, class 6233-01; NOM Certified
• ArrowLink: Plug & connector cULus Listed to UL2459 file no.
E325188
• Combined: cULus Listed wiring assembly, UL file no. E326691
• Nylon with PVC terminal guards
• Environmental, Base Device: Flammability meets UL 94 requirements; V2 rated;
temperature rating -20ºC to 70ºC (-4ºF to 158ºF)
• Environmental, ArrowLink: Flammability meets UL 94 requirements; V2 rated; temperature
rating: -20ºC to 90ºC (-4ºF to 194ºF) max.
11
Modular Receptacles
Project Name:
Prepared By:
Project Number:
Date:
Catalog Number:
Type:
Straight Blade Receptacles
1.30"
(33.0mm)
Construction Grade Duplex Receptacles
4.19"
(106.1mm)
3.28"
(83.3mm)
CR5262_M
2-Pole, 3-Wire Grounding
15A 125V
20A 125V
Depth with
ArrowLink
1.31"
(33.2mm)
FEATURES
• ArrowLink modular plug and connector provide
high quality circuit connections and incorporate a
first make/last break grounding design.
• Wire leads are crimped and resistance welded
to plug and connector terminals for maximum
durability.
• Audible “click” when mating plug and connector
indicates proper assembly during final device
installation.
• Pre-wired plugs provide 100% inspected and
consistent torque settings for reliable connections
to base devices.
• Connectors shipped with re-usable protective
covering that allows circuit testing while
protecting the connection from foreign matter.
• Exclusive screw terminal guards provide a
protective barrier from conductive surfaces.
• Compact, rugged design ideally suited to perform
in the demanding construction specification
grade field.
• Excellent plug blade retention provided by 0.037"
(0.94mm) triple-wipe brass line contacts and 0.030"
(0.76mm) brass ground.
• 0.050" (1.27mm) galvanized steel, wrap-around
yoke mounting strap for superior assembly
security; extra length/width helps reach large panel
cutouts for code compliance.
• High impact and chemical-resistant nylon face.
• Screw-Catch™ feature speeds mounting of
wallplates.
Back Wire and Side Wire – Compact Design
1.42"
(36.1mm)
Lead
Length:
6.00”
(152.4mm)
0.40"
(10.2mm)
F
Catalog No.
R
S
Rating
A V
15 125
NEMA
5-15R
Description
Duplex Modular Receptacle
I CR5262___M
Available
Colors
B, GY, LA, V, W
20 125
5-20R
Duplex Modular Receptacle
I CR5362___M
B, BK, GY, LA, V, W
For ordering, include Cat. No. followed by the color code: B (Brown), BK (Black), GY (Gray), LA (Light Almond), V (Ivory),
W (White)
1.08"
(27.4mm)
Receptacle
Connector
1.42"
(36.1mm)
ArrowLink Receptacle Connectors
0.40"
(10.2mm)
Description
1.08"
(27.4mm)
Receptacle
Plug
G
5-15R
W
G
C
Catalog No.
ArrowLink Modular Receptacle 125V Building Wire Connector, Solid Wire
I MCR125SOL
ArrowLink Modular Receptacle 125V Building Wire Connector, Stranded Wire
I MCR125STR
Patent Pending
W
5-20R
For Specification & Performance
Data, see page 14.
TESTING & CODE COMPLIANCE
MATERIAL CHARACTERISTICS
• Base Device: UL Listed to UL498, file no. E15058; UL verified
to Federal Spec. WS-596G; CSA Certified to C22.2, no. 42, file
no. 6914, class 6233-01
• ArrowLink: Plug & connector cULus Listed to UL2459 file no.
E325188
• Combined: cULus Listed wiring assembly, UL file no. E326691
• Nylon & PVC with adhesive terminal barrier
• Environmental, Base Device: Flammability meets UL 94 requirements;
V2 rated; temperature rating: -20ºC to 60ºC (-4ºF to 140ºF)
• Environmental, ArrowLink: Flammability meets UL 94 requirements; V2
rated; temperature rating: -20ºC to 90ºC (-4ºF to 194ºF) max.
12
R
US
Modular Receptacles
Specification & Performance Data
Project Name:
Prepared By:
Project Number:
Date:
Catalog Number:
Type:
Straight Blade Receptacles
2-Pole, 3-Wire Grounding
15A 125V, 15A 250V
20A 125V, 20A 250V
Application
Specification grade duplex receptacles are challenged on a daily basis to provide a consistent, reliable means of connectivity in a wide
variety of environments. The applications vary greatly by environment and provide challenges from impact and chemical resistance to
environmental extremes such as heat and moisture. The breadth of the Arrow Hart ArrowLink Straight Blade Receptacle line provides
solutions for the widest variety of environments and applications. Features include high impact- and chemical-resistant nylon faces to
withstand abuse and maintain structural integrity plus durable contact designs for long life blade retention and reduction of potential heat
build up. Safety barriers provide insulation from conductive surfaces. Patent-pending modular plug and connector provide consistent high
quality circuit connections and reduce overall installation time on the job.
Receptacle Type
Industrial Grade Duplex: 5262_M, 5362_M, 5462_M, 5662_M
Series; ArrowLink: MCR125_, MCR250_ Series
Industrial Grade Single: 5261_M, 5361_M Series;
ArrowLink: MCR125_ Series
Wiring Type
Base Device: Back & side wire
ArrowLink: Integral wire leads, crimped & resistance welded
Base Device: Back & side wire
ArrowLink: Integral wire leads, crimped & resistance welded
Testing & Code Compliance
•
Base Device
•
•
•
ArrowLink
•
Combined
UL Listed to UL498, file no. E15058
UL verified to Federal Spec. WS-596G
CSA Certified to C22.2, no. 42, file no. 6914, class 6233-01
NOM Certified
•
•
•
•
Plug & connector cULus Listed to UL2459 file no. E325188
• Plug & connector cULus Listed to UL2459 file no. E325188
UL Listed to UL498, file no. E15058
UL verified to Federal Spec. WS-596G
CSA Certified to C22.2, no. 42, file no. 6914, class 6233-01
NOM Certified
• cULus Listed wiring assembly, UL file no. E326691
• cULus Listed wiring assembly, UL file no. E326691
Flammability meets UL 94 requirements; V2 rated
Temperature rating: -20ºC to 70ºC (-4ºF to 158ºF)
Flammability meets UL 94 requirements; V2 rated
Temperature rating: -20ºC to 60ºC (-4ºF to 140ºF)
Environmental,
ArrowLink
Flammability meets UL 94 requirements; V2 rated
Temperature rating: -20ºC to 90ºC (-4ºF to 194ºF) max.
Flammability meets UL 94 requirements; V2 rated
Temperature rating: -20ºC to 90ºC (-4ºF to 194ºF) max.
Electrical, Base Device
Dielectric Voltage: withstands 2000V per UL498
Temperature Rise: max. 30ºC (86°F) after 250 cycles of overload @
200% of rated current (DC)
Current interrupting: yes, at full-rated current
Dielectric Voltage: withstands 2000V per UL498
Temperature Rise: max. 30ºC (86°F) after 250 cycles of overload @
200% of rated current (DC)
Current interrupting: yes, at full-rated current
Electrical, ArrowLink
Maximum working voltage 300V / AC
Overload: 52.5A / AC for 10 cycles
Temperature Rise: Max. 50ºC (122°F) while conducting 35A after 10
cycles of overload @ 52.5A / AC
Dielectric Voltage: withstands 1600V per UL2459
Maximum continuous current: 20A
Current interrupting: limited cycles at full-rated current
Maximum working voltage 300V / AC
Overload: 52.5A / AC for 10 cycles
Temperature Rise: Max. 50ºC (122°F) while conducting 35A after 10
cycles of overload @ 52.5A / AC
Dielectric Voltage: withstands 1600V per UL2459
Maximum continuous current: 20A
Current interrupting: limited cycles at full-rated current
Mechanical
Base Device Terminal Accommodation: #14 - #10 AWG
ArrowLink Wire Leads: #12 AWG
Voltage ratings permanently marked on device
Base Device Terminal Accommodation: #14 - #10 AWG
ArrowLink Wire Leads: #12 AWG
Voltage ratings permanently marked on device
Screw Terminal Guards
Material: PVC hinged doors
Material: UL Recognized Insulating Material
Dielectric Strength: 2,000V Min
HWI Rating: 4 Min.
Relative Temperature Index, Electrical: 80ºC (176ºF)
Flammability: V0 (UL94)
Specifications:
Environmental,
Base Device
Materials
Top Housing
Thermoplastic, nylon
Thermoplastic, nylon
Bottom Housing
Glass-filled nylon
Nylon
Strap
0.05" thick solid brass
0.05" thick steel, zinc plated, yellow chromate
Auto Ground Clip
Brass
Phosphor bronze
Line Contacts
0.032" thick 5-leaf brass
.037" thick triple-wipe brass
Terminal & Ground
Screws
#8-32 brass, neutral screw nickel plated, ground screw green
#8-32 brass; neutral screw nickel plated, ground screw green
ArrowLink Housing
Polycarbonate
Polycarbonate
ArrowLink Contacts
Copper alloy
Copper alloy
ArrowLink Wire Leads
Solid or stranded THHN #12 AWG
Solid or stranded THHN #12 AWG
13
Modular Receptacles
Specification & Performance Data
Project Name:
Prepared By:
Project Number:
Date:
Catalog Number:
Type:
Straight Blade Receptacles
2-Pole, 3-Wire Grounding
15A 125V
20A 125V
Application
Specification grade duplex receptacles are challenged on a daily basis to provide a consistent, reliable means of connectivity in a wide
variety of environments. The applications vary greatly by environment, and provide challenges from impact and chemical resistance to
environmental extremes such as heat and moisture. The breadth of the Arrow Hart ArrowLink Straight Blade Receptacle line provides
solutions for all environments and applications. Features include high impact- and chemical-resistant nylon faces to withstand abuse and
maintain structural integrity plus durable contact designs for long life blade retention and reduction of potential heat build up. Safety barriers
provide insulation from conductive surfaces. Patent-pending modular plug and connector provide consistent high quality circuit connections
and reduce overall installation time on the job.
Receptacle Type
Industrial Grade: Decorator Duplex 6262_M, 6362_M Series;
Duplex 5252_M, 5352_M Series; ArrowLink: MCR125_Series
Construction Grade Duplex CR5262_M, CR5362_M Series;
ArrowLink: MCR125_ Series
Wiring Type
Base Device: Back & side wire
ArrowLink: Integral wire leads, crimped & resistance welded
Base Device: Back & side wire
ArrowLink: Integral wire leads, crimped & resistance welded
Testing & Code Compliance
•
Base Device
•
•
•
ArrowLink
•
Combined
• UL Listed to UL498, file no. E15058
• UL verified to Federal Spec. WS-596G
• CSA Certified to C22.2, no. 42, file no. 6914, class 6233-01
Plug & connector cULus Listed to UL2459 file no. E325188
• Plug & connector cULus Listed to UL2459 file no. E325188
• cULus Listed wiring assembly, UL file no. E326691
• cULus Listed wiring assembly, UL file no. E326691
Flammability meets UL 94 requirements; V2 rated
Temperature rating: -20ºC to 70ºC (-4ºF to 158ºF)
Flammability meets UL 94 requirements; V2 rated
Temperature rating: -20ºC to 60ºC (-4ºF to 140ºF)
Environmental,
ArrowLink
Flammability meets UL 94 requirements; V2 rated
Temperature rating: -20ºC to 90ºC (-4ºF to 194ºF) max.
Flammability meets UL 94 requirements; V2 rated
Temperature rating: -20ºC to 90ºC (-4ºF to 194ºF) max.
Electrical, Base Device
Dielectric Voltage: withstands 2000V per UL498
Temperature Rise: max. 30ºC (86°F) after 250 cycles of overload @
200% of rated current (DC)
Current interrupting: yes, at full-rated current
Dielectric Voltage: withstands 2000V per UL498
Temperature Rise: max. 30ºC (86°F) after 250 cycles of overload @
200% of rated current (DC)
Current interrupting: yes, at full-rated current
Electrical, ArrowLink
Maximum working voltage 300V / AC
Overload: 52.5A / AC for 10 cycles
Temperature Rise: Max. 50ºC (122°F) while conducting 35A after 10
cycles of overload @ 52.5A / AC
Dielectric Voltage: withstands 1600V per UL2459
Maximum continuous current: 20A
Current interrupting: limited cycles at full-rated current
Maximum working voltage 300V / AC
Overload: 52.5A / AC for 10 cycles
Temperature Rise: Max. 50ºC (122°F) while conducting 35A after 10
cycles of overload @ 52.5A / AC
Dielectric Voltage: withstands 1600V per UL2459
Maximum continuous current: 20A
Current interrupting: limited cycles at full-rated current
Mechanical
Base Device Terminal Accommodation: #14 - #10 AWG
ArrowLink Wire Leads: #12 AWG
Voltage ratings permanently marked on device
Base Device Terminal Accommodation: #14 - #10 AWG
ArrowLink Wire Leads: #12 AWG
Voltage ratings permanently marked on device
Screw Terminal Guards
Material: PVC hinged doors
Material: UL Recognized Insulating Material
Dielectric Strength: 2,000V Min
HWI Rating: 4 Min.
Relative Temperature Index, Electrical: 80ºC (176ºF)
Flammability: V0 (UL94)
Specifications:
Environmental,
Base Device
Materials
Top Housing
14
UL Listed to UL498, file no. E15058
UL verified to Federal Spec. WS-596G
CSA Certified to C22.2, no. 42, file no. 6914, class 6233-01
NOM Certified
Thermoplastic, nylon
Thermoplastic, nylon
Bottom Housing
Glass-filled nylon
PVC
Strap
0.05" thick galvanized steel
0.05" thick galvanized steel
Ground Contact
0.05" thick solid brass ground shunt
0.032" thick brass ground contact
Auto Ground Clip
Brass
Phosphor bronze
Line Contacts
0.032" thick 5-leaf brass
.037" thick triple-wipe brass
Terminal & Ground
Screws
#8-32 brass, neutral screw nickel plated, ground screw green
#8-32 steel, brass plated; neutral screw nickel plated, ground screw
green
ArrowLink Housing
Polycarbonate
Polycarbonate
ArrowLink Contacts
Copper alloy
Copper alloy
ArrowLink Wire Leads
Solid or stranded THHN #12 AWG
Solid or stranded THHN #12 AWG
Modular Hospital Grade
Project Name:
Prepared By:
Project Number:
Date:
Catalog Number:
Type:
Hospital Grade Straight
Blade Receptacles
2-Pole, 3-Wire Grounding
15A 125V, 15A 250V
20A 125V, 20A 250V
1.32"
(33.5mm)
Hospital Grade Duplex Receptacles
FEATURES
• ArrowLink modular plug and connector provide
high quality circuit connections and incorporate a
first make/last break grounding design.
• Wire leads are crimped and resistance welded
to plug and connector terminals for maximum
durability.
• Audible “click” when mating plug and connector
indicates proper assembly during final device
installation.
• Pre-wired plugs provide 100% inspected and
consistent torque settings for reliable connections
to base devices.
• Connectors shipped with re-usable protective
covering that allows circuit testing while protecting
the connection from foreign matter.
• Exclusive screw terminal guards provide a
protective barrier from conductive surfaces.
• Exclusive 5-leaf brass line contacts ensure lowest
heat rise, smooth plug blade insertion, long-term
retention and corrosion resistance.
• 0.050" (1.27mm) solid brass mounting strap with
non-riveted, integral one-piece grounding system
assures superior ground integrity, durability and
corrosion resistance under heaviest use.
• Long-life neon bulb in illuminated devices easily
locates emergency circuits.
Back Wire and Side Wire – 1 Piece Brass Ground System
Rating
A V
15 125
Catalog No.
NEMA
5-15R
Description
Hospital Duplex Modular Receptacle
Hospital Duplex Illuminated
Modular Receptacle
Hospital Decorator Duplex
Modular Receptacle
Hospital Decorator Duplex Illuminated
Modular Receptacle
15 250
20 125
6-15R
5-20R
Hospital Duplex Modular Receptacle
Hospital Duplex Modular Receptacle
Hospital Duplex Illuminated
Modular Receptacle
Hospital Decorator Duplex
Modular Receptacle
Hospital Decorator Duplex Illuminated
Modular Receptacle
20 250
6-20R
Hospital Duplex Modular Receptacle
I 8200___M
I 8200LT___M
F
R
3.28"
(83.3mm)
8362_M
1.32"
(33.5mm)
426
Available
Colors
B, BK, GY, RD, V, W
3.28"
(83.3mm)
RD, V, W
B, BK, GY, RD, V, W
I 8262LT___M
V, W
I 8600___M*
V, W
8200_M
I 8300LT___M
RD, V, W
I 8362___M
B, BK, GY, RD, V, W
I 8362LT___M
RD, V, W
I 8400___M*
B, GY, RD, V, W
Lead
Length:
6.00”
(152.4mm)
0.40"
(10.2mm)
1.08"
(27.4mm)
Receptacle
Connector
1.42"
(36.1mm)
0.40"
(10.2mm)
For ordering, include Cat. No. followed by the color code: B (Brown), BK (Black), GY (Gray), LA (Light Almond), RD (Red), V
(Ivory), W (White)
1.08"
(27.4mm)
*Not NOM Certified
C
Description
ArrowLink Modular Receptacle 125V Building Wire Connector, Solid Wire
ArrowLink Modular Receptacle 125V Building Wire Connector, Stranded Wire
ArrowLink Modular Receptacle 250V Building Wire Connector, Solid Wire
ArrowLink Modular Receptacle 250V Building Wire Connector, Stranded Wire
Catalog No.
I MCR125SOL
R
US
Receptacle
Plug
G
I MCR125STR
I MCR250SOL
I MCR250STR
Patent Pending
Depth with
ArrowLink
1.31"
(33.2mm)
1.42"
(36.1mm)
B, BK, GY, LA, RD, V, W
ArrowLink Receptacle Connectors
Depth with
ArrowLink
1.31"
(33.2mm)
4.19"
(106.4mm)
S
I 8262___M
I 8300___M
4.19"
(106.4mm)
5-15R
W
G
W
5-20R
G
6-15R
G
6-20R
For Specification & Performance
Data, see page 17.
TESTING & CODE COMPLIANCE
MATERIAL CHARACTERISTICS
• Base Device: UL Listed to UL498, file no E15058; UL verified to
Federal Spec. WC-596G; CSA Certified to C22.2, no. 42, file no.
6914, class 6233-01; NOM Certified, except 8400, 8600
• ArrowLink: Plug & connector cULus Listed to UL2459 file no.
E325188
• Combined: cULus Listed wiring assembly, UL file no. E326691
• Nylon with PVC terminal guards
• Environmental, Base Device: Flammability meets UL 94 requirements; V2 rated; temperature
rating: -40ºC to 60ºC (-40ºF to 140ºF), except decorator: -20ºC to 70ºC (-4ºF to 158ºF)
• Environmental, ArrowLink: Flammability meets UL 94 requirements; V2 rated; temperature
rating: -20ºC to 90ºC (-4ºF to 194ºF) max.
15
Modular Hospital Grade
Project Name:
Prepared By:
Project Number:
Date:
Catalog Number:
Type:
Hospital Grade Straight
Blade Receptacles
1.30"
(33.0mm)
Hospital Grade Tamper Resistant, Compact & Single Receptacles
Tamper Resistant
3.28"
(83.3mm)
4.19"
(106.4mm)
TR8200_M
Depth with
ArrowLink
1.31"
(33.2mm)
3.28"
(83.3mm)
1.98"
(50.3mm)
2.38"
(60.3mm)
2-Pole, 3-Wire Grounding
15A 125V
20A 125V
Depth with
ArrowLink
1.41"
(35.8mm)
8310_M
FEATURES
• ArrowLink modular plug and connector provide
high quality circuit connections and incorporate a
first make/last break grounding design.
• Wire leads are crimped and resistance welded
to plug and connector terminals for maximum
durability.
• Audible “click” when mating plug and connector
indicates proper assembly during final device
installation.
• Pre-wired plugs provide 100% inspected and
consistent torque settings for reliable connections
to base devices.
• Connectors shipped with re-usable protective
covering that allows circuit testing while
protecting the connection from foreign matter.
• Exclusive screw terminal guards provide a
protective barrier from conductive surfaces.
• Compact devices have a sturdy design that
delivers full hospital grade performance in a
lower profile.
• Tamper Resistant devices feature a
patented spring-loaded mechanical shutter
system for reliable tamper resistance and
compliance with NEC® Art. 517.18(C) requiring
tamper resistant outlets in pediatric care locations.
• Heavy gauge, 0.037" (0.94mm) triple-wipe brass
line contacts provide excellent long-term plug
blade retention.
• High impact- and chemical-resistant nylon face.
• 0.030" (0.76mm) solid brass, non-riveted, integral
one-piece grounding shunt system assures ground
integrity under heaviest use.
• Long, broad mounting strap helps reach large panel
cutouts for code compliance.
• Screw-Catch™ feature on duplex devices speeds
mounting of wallplates.
Tamper Resistant
Back Wire and Side Wire – Brass Ground Shunt
Rating
A V
15 125
1.42"
(36.1mm)
Lead
Length:
6.00”
(152.4mm)
0.40"
(10.2mm)
NEMA
5-15R
Description
Tamper Resistant Hospital Duplex
Modular Receptacle
5-20R
1.42"
(36.1mm)
Tamper Resistant Hospital Duplex
Modular Receptacle
0.40"
(10.2mm)
Receptacle
Plug
F
R
I 8200H___M
B, GY, RD, V, W
I 8210___M
B, GY, RD, V, W
I TR8300___M* B, GY, RD, V, W
Tamper Resistant
Compact Hospital Duplex
Modular Receptacle
1.08"
(27.4mm)
US
Hospital Single Modular Receptacle
I 8300H___M
B, GY, RD, V, W
I 8310___M
B, GY, RD, V, W
5-15R
W
G
Description
W
5-20R
For Specification & Performance
Data, see pages 17 & 18.
AVAILABLE
Q2 2009!
AVAILABLE
Q2 2009!
For ordering, include Cat. No. followed by the color code: B (Brown), GY (Gray), RD (Red), V (Ivory), W (White)
* Not CSA Certified
ArrowLink Receptacle Connectors
G
S
Tamper Resistant
Hospital Single Modular Receptacle
20 125
R
Available
Colors
I TR8200___M* B, GY, RD, V, W
Compact Hospital Duplex
Modular Receptacle
1.08"
(27.4mm)
Receptacle
Connector
C
Catalog No.
C
R
Catalog No.
ArrowLink Modular Receptacle 125V Building Wire Connector, Solid Wire
I MCR125SOL
ArrowLink Modular Receptacle 125V Building Wire Connector, Stranded Wire
I MCR125STR
Patent Pending
TESTING & CODE COMPLIANCE
MATERIAL CHARACTERISTICS
• Base Device: UL Listed to UL498, file no. E15058, except TR: cULus
Listed; UL verified to Federal Spec. WC-596G; compact & single also
CSA Certified to C22.2, no. 42, file no. 6914, class 6233-01
• ArrowLink: Plug & connector cULus Listed to UL2459 file no.
E325188
• Combined: cULus Listed wiring assembly, UL file no. E326691
• Nylon with adhesive terminal barrier, except TR: nylon & PVC
• Environmental, Base Device: Flammability meets UL 94 requirements; V2 rated;
temperature rating: -40ºC to 60ºC (-40ºF to 140ºF), except compact: -20ºC to 70ºC
(-4ºF to 158ºF), single: -20ºC to 60ºC (-4ºF to 140ºF)
• Environmental, ArrowLink: Flammability meets UL 94 requirements; V2 rated;
temperature rating: -20ºC to 90ºC (-4ºF to 194ºF) max.
16
US
Modular Hospital Grade Receptacles
Specification & Performance Data
Project Name:
Prepared By:
Project Number:
Date:
Catalog Number:
Type:
Hospital Grade Straight
Blade Receptacles
2-Pole, 3-Wire Grounding
15A 125V, 15A 250V
20A 125V, 20A 250V
Application
From abrupt plug removal to corrosive cleaning agents, receptacles in health care facilities are challenged to provide consistent and reliable
connectivity with critical consequences. ArrowLink Hospital Grade Straight Blade Devices provide consistent performance under the most
demanding conditions with features including high impact- and chemical-resistant nylon faces, glass reinforced nylon bases for superior
strength and heat resistance plus durable contact designs for long life, enhanced blade retention and reduction of potential heat build-up.
Receptacle Type
Hospital Grade Decorator Duplex
Receptacle: 8262_M, 8362_M Series;
ArrowLink: MCR125_ Series
Hospital Grade Duplex Receptacle:
8200_M, 8300_M, 8400_M, 8600_M Series;
ArrowLink: MCR125_, MCR250_ Series
Hospital Grade Compact Duplex
Receptacle: 8200H_M, 8300H_M Series;
ArrowLink: MCR125_ Series
Wiring Type
Base Device: Back & side wire
ArrowLink: Integral wire leads, crimped &
resistance welded
• UL Listed to UL498, file no E15058
• UL verified to Federal Spec. WC-596G
• CSA Certified to C22.2, no. 42, file no.
6914, class 6233-01
• NOM Certified
Base Device: Back & side wire
ArrowLink: Integral wire leads, crimped &
resistance welded
• UL Listed to UL498, file no E15058
• UL verified to Federal Spec. WC-596G
• CSA Certified to C22.2, no. 42, file no
6914, class 6233-01
• NOM Certified except 8400, 8600
Base Device: Back & side wire
ArrowLink: Integral wire leads, crimped &
resistance welded
• UL Listed to UL498, file no E15058
• UL verified to Federal Spec. WC-596G
• CSA Certified to C22.2, no. 42, file no.
6914, class 6233-01
ArrowLink • Plug & connector cULus Listed to UL2459
file no. E325188
• Plug & connector cULus Listed to UL2459
file no. E325188
• Plug & connector cULus Listed to UL2459
file no. E325188
Combined • cULus Listed wiring assembly, UL file no.
E326691
• cULus Listed wiring assembly, UL file no.
E326691
• cULus Listed wiring assembly, UL file no.
E326691
Flammability meets UL 94 requirements; V2
rated
Temperature rating: -20ºC to 70ºC (-4ºF to
158ºF)
Flammability meets UL 94 requirements; V2
rated
Temperature rating: -40ºC to 60ºC (-40ºF to
140ºF)
Flammability meets UL 94 requirements; V2
rated
Temperature rating: -20ºC to 70ºC (-4ºF to
158ºF)
Environmental,
ArrowLink
Flammability meets UL 94 requirements; V2
rated
Temperature rating: -20ºC to 90ºC (-4ºF to
194ºF) max.
Flammability meets UL 94 requirements; V2
rated
Temperature rating: -20ºC to 90ºC (-4ºF to
194ºF) max.
Flammability meets UL 94 requirements; V2
rated
Temperature rating: -20ºC to 90ºC (-4ºF to
194ºF) max.
Electrical, Base Device
Dielectric Voltage: withstands 2000V per
UL498
Temperature Rise: max. 30ºC (86°F) after 250
cycles of overload @ 200% of rated
current (DC)
Current interrupting: yes, at full-rated current
Dielectric Voltage: withstands 2000V per
UL498
Temperature Rise: max. 30ºC (86°F) after 250
cycles of overload @ 200% of rated
current (DC)
Current interrupting: yes, at full-rated current
Dielectric Voltage: withstands 2000V per
UL498
Temperature Rise: max. 30ºC (86°F) after 250
cycles of overload @ 200% of rated
current (DC)
Current interrupting: yes, at full-rated current
Electrical, ArrowLink
Maximum working voltage 300V / AC
Overload: 52.5A / AC for 10 cycles
Temperature Rise: Max. 50ºC (122°F) while
conducting 35A after 10 cycles of overload
@ 52.5A / AC
Dielectric Voltage: withstands 1600V per
UL2459
Maximum continuous current: 20A
Current interrupting: limited cycles at fullrated current
Maximum working voltage 300V / AC
Overload: 52.5A / AC for 10 cycles
Temperature Rise: Max. 50ºC (122°F) while
conducting 35A after 10 cycles of overload
@ 52.5A / AC
Dielectric Voltage: withstands 1600V per
UL2459
Maximum continuous current: 20A
Current interrupting: limited cycles at fullrated current
Maximum working voltage 300V / AC
Overload: 52.5A / AC for 10 cycles
Temperature Rise: Max. 50ºC (122°F) while
conducting 35A after 10 cycles of overload
@ 52.5A / AC
Dielectric Voltage: withstands 1600V per
UL2459
Maximum continuous current: 20A
Current interrupting: limited cycles at fullrated current
Mechanical
Base Device Terminal Accommodation: #14 #10 AWG
ArrowLink Wire Leads: #12 AWG
Voltage ratings permanently marked on
device
Base Device Terminal Accommodation: #14 #10 AWG
ArrowLink Wire Leads: #12 AWG
Voltage ratings permanently marked on
device
Base Device Terminal Accommodation: #14 #10 AWG
ArrowLink Wire Leads: #12 AWG
Voltage ratings permanently marked on
device
Screw Terminal Guards
Material: PVC hinged doors
Material: PVC hinged doors
Material: PVC hinged doors
Testing & Code
Compliance
Base
Device
Specifications:
Environmental,
Base Device
Materials
Top Housing
Thermoplastic, nylon
Thermoplastic, nylon
Thermoplastic, nylon
Bottom Housing
Glass-filled nylon
Glass-filled nylon
Nylon
Strap
0.05" thick solid brass
0.05" thick solid brass, nickel plated
0.05" thick steel, zinc plated
Auto Ground Clip
Brass
Brass
Bronze wire
Line Contacts
0.032" thick 5-leaf brass
0.032" thick 5-leaf brass, nickel plated
0.037" triple-wipe brass
Terminal & Ground
Screws
#8-32 steel, ground screw green
#8-32 brass, neutral screw nickel plated,
ground screw green
#8-32 steel, ground screw green
Illuminated Models
Long-life neon bulb
Long-life neon bulb
N/A
ArrowLink Housing
Polycarbonate
Polycarbonate
Polycarbonate
ArrowLink Contacts
Copper alloy
Copper alloy
Copper alloy
ArrowLink Wire Leads
Solid or stranded THHN #12 AWG
Solid or stranded THHN #12 AWG
Solid or stranded THHN #12 AWG
17
Modular Hospital Grade Receptacles
Specification & Performance Data
Project Name:
Prepared By:
Project Number:
Date:
Catalog Number:
Type:
Hospital Grade Straight
Blade Receptacles
2-Pole, 3-Wire Grounding
15A 125V
20A 125V
Application
Health care facilities are some of the most demanding environments for electrical receptacles. From abrupt plug removal to corrosive
cleaning agents, these devices are challenged on a daily basis to provide a consistent, reliable means of connectivity with critical
consequences. Arrow Hart’s line of ArrowLink Hospital Grade Straight Blade Devices provide the breadth of line needed for all environments
within these facilities. These devices provide consistent performance under the most demanding conditions with features including high
impact- and chemical-resistant nylon faces, glass reinforced nylon bases for superior strength and heat resistance, durable contact designs
for long life, enhanced blade retention and reduction of potential heat build-up, plus back and side wiring capabilities that reduce installation
time and provide high quality terminations. Safety barriers provide insulation from conductive surfaces. Patent-pending modular plug and
connector provide consistent high quality circuit connections and reduce overall installation time on the job.
Receptacle Type
Wiring Type
Hospital Grade Tamper Resistant
Duplex Receptacle: TR8200_M, TR8300_M Series;
ArrowLink: MCR125_Series
Tamper Resistant
Base Device: Back & side wire
ArrowLink: Integral wire leads, crimped & resistance welded
Testing & Code Compliance
• cULus listed to UL498, file no. E15058
Base Device
• UL verified to Federal Spec. WC-596G
Base Device: Back & side wire
ArrowLink: Integral wire leads, crimped & resistance welded
• UL listed to UL498, file no. E15058
• UL verified to Federal Spec. WC-596G
• CSA Certified to C22.2, no. 42, file no. 6914, class 6233-01
ArrowLink
• Plug & connector cULus Listed to UL2459 file no. E325188
• Plug & connector cULus Listed to UL2459 file no. E325188
Combined
• cULus Listed wiring assembly, UL file no. E326691
• cULus Listed wiring assembly, UL file no. E326691
Flammability meets UL 94 requirements; V2 rated
Temperature rating: -40ºC to 60ºC (-40ºF to 140ºF)
Flammability meets UL 94 requirements; V2 rated
Temperature rating: -20ºC to 60ºC (-4ºF to 140ºF)
Environmental,
ArrowLink
Flammability meets UL 94 requirements; V2 rated
Temperature rating: -20ºC to 90ºC (-4ºF to 194ºF) max.
Flammability meets UL 94 requirements; V2 rated
Temperature rating: -20ºC to 90ºC (-4ºF to 194ºF) max.
Electrical, Base Device
Dielectric Voltage: withstands 2000V per UL 498
Temperature Rise: max. 30ºC (86°F) after 250 cycles of overload @
200% of rated current (DC)
Current interrupting: yes, at full-rated current
Dielectric Voltage: withstands 2000V per UL 498
Temperature Rise: max. 30ºC (86°F) after 2500 cycles of overload @
200% of rated current (DC)
Current interrupting: yes, at full-rated current
Electrical, ArrowLink
Maximum working voltage 300V / AC
Overload: 52.5A / AC for 10 cycles
Temperature Rise: Max. 50ºC (122°F) while conducting 35A after 10
cycles of overload @ 52.5A / AC
Dielectric Voltage: withstands 1600V per UL2459
Maximum continuous current: 20A
Current interrupting: limited cycles at full-rated current
Maximum working voltage 300V / AC
Overload: 52.5A / AC for 10 cycles
Temperature Rise: Max. 50ºC (122°F) while conducting 35A after 10
cycles of overload @ 52.5A / AC
Dielectric Voltage: withstands 1600V per UL2459
Maximum continuous current: 20A
Current interrupting: limited cycles at full-rated current
Mechanical
Base Device Terminal Accommodation: #14 - #10 AWG
ArrowLink Wire Leads: #12 AWG
Voltage ratings permanently marked on device
Base Device Terminal Accommodation: #14 - #10 AWG
ArrowLink Wire Leads: #12 AWG
Voltage ratings permanently marked on device
Screw Terminal Guards
Material: UL Recognized Insulating Material
Dielectric Strength: 2,000V Min
HWI Rating: 4 Min.
Relative Temperature Index, Electrical: 80ºC (176ºF)
Flammability: V0 (UL94)
Material: UL Recognized Insulating Material
Dielectric Strength: 2,000V Min
HWI Rating: 4 Min.
Relative Temperature Index, Electrical: 80ºC (176ºF)
Flammability: V0 (UL94)
Specifications:
Environmental,
Base Device
Materials
Top Housing
18
Hospital Grade Single Receptacle:
8210_M, 8310_M Series;
ArrowLink: MCR125_ Series
Thermoplastic, nylon
Thermoplastic, nylon
Bottom Housing
PVC
Nylon
Strap
0.05" thick steel, zinc plated
0.05" thick galvanized steel
Auto Ground Clip
Brass
Bronze wire
Line Contacts
0.037" triple wipe brass
0.037" triple wipe brass
Terminal & Ground
Screws
#8-32 brass; neutral screw nickel plated, ground screw green
#8-32 steel; neutral screw nickel plated, ground screw green
ArrowLink Housing
Polycarbonate
Polycarbonate
ArrowLink Contacts
Copper alloy
Copper alloy
ArrowLink Wire Leads
Solid or stranded THHN #12 AWG
Solid or stranded THHN #12 AWG
Modular GFCIs
Project Name:
Prepared By:
Project Number:
Date:
Catalog Number:
Type:
Ground Fault Circuit
Interrupters
2-Pole, 3-Wire Grounding
15A 125V
20A 125V
1.30"
(33.0mm)
Hospital & Specification Grade GFCIs
FEATURES
• ArrowLink modular plug and connector provide
high quality circuit connections and incorporate a
first make/last break grounding design.
• Wire leads are crimped and resistance welded
to plug and connector terminals for maximum
durability.
• Audible “click” when mating plug and connector
indicates proper assembly during final device
installation.
• Pre-wired plugs provide 100% inspected and
consistent torque settings for reliable connections
to base devices.
• Connectors shipped with re-usable protective
covering that allows circuit testing while
protecting the connection from foreign matter.
• Exclusive screw terminal guards provide a
protective barrier from conductive surfaces.
• Hospital Grade models UL Listed, fully compliant
with all latest UL943 (4th edition) Class A GFCI and
UL498 Hospital Grade requirements.
• Tamper Resistant models comply with 2008
NEC® Article 406.11 requiring all dwelling
unit receptacles to be tamper resistant.
• ShockSentry™ lock-out function prevents miswired
line-load connections and GFCI circuitry damage.
• Large visual indicator light provides quick visual
reference of a tripped or “end of life” condition.
• 20A feed through rating.
• Longer, wider “bridged” strap provides 40% more
contact area with wallboard, virtually eliminating
floating installations.
• Matching standard size thermoplastic wallplate
included.
Catalog No.
NEMA
5-15R
Description
Tamper Resistant GFCI
Modular Receptacle
Tamper Resistant
AVAILABLE
Q2 2009!
GFCI Modular Receptacle
20 125
5-20R
Tamper Resistant GFCI
Modular Receptacle
Tamper Resistant
3.28"
(83.3mm)
Tamper Resistant
Hospital Specification Grade – Back Wire and Side Wire
Rating
A V
15 125
4.19"
(106.4mm)
AVAILABLE
Q2 2009!
GFCI Modular Receptacle
C
I TRVGFH15___M
Available
Colors
LA, RD, W
I VGFH15___M
LA, RD, W
R
US
Depth with
ArrowLink
1.64"
(41.7mm)
VGFH20_M
1.30"
(33.0mm)
4.19"
(106.4mm)
Tamper Resistant
3.28"
(83.3mm)
426
TRVGF15_M
I TRVGFH20___M
B, GY, LA, RD, V, W
I VGFH20___M
B, GY, LA, RD, V, W
Depth with
ArrowLink
1.64"
(41.7mm)
1.42"
(36.1mm)
Lead
Length:
6.00”
(152.4mm)
0.40"
(10.2mm)
1.08"
(27.4mm)
Specification Grade – Back Wire and Side Wire
Rating
A V
15 125
Catalog No.
NEMA
5-15R
Description
Tamper Resistant GFCI
Modular Receptacle
Tamper Resistant
GFCI Modular Receptacle
20 125
C
5-20R
Tamper Resistant GFCI
Modular Receptacle
R
US
426
I TRVGF15___M
Available
Colors
A, B, BK, GY, LA, V, W
I VGF15___M
A, B, BK, GY, LA, V, W
I TRVGF20___M
A, B, BK, GY, LA, V, W
I VGF20___M
A, B, BK, GY, LA, V, W
Tamper Resistant
GFCI Modular Receptacle
For ordering, include Cat. No. followed by the color code: A (Almond), B (Brown), BK (Black), GY (Gray), LA (Light Almond), RD
(Red), V (Ivory), W (White)
ArrowLink Receptacle Connectors
C
Description
R
US
Receptacle
Connector
1.42"
(36.1mm)
0.40"
(10.2mm)
1.08"
(27.4mm)
Receptacle
Plug
G
Catalog No.
ArrowLink Modular Receptacle 125V Building Wire Connector, Solid Wire
I MCR125SOL
ArrowLink Modular Receptacle 125V Building Wire Connector, Stranded Wire
I MCR125STR
Patent Pending
W
5-15R
G
W
5-20R
For Specification & Performance
Data, see page 20.
TESTING & CODE COMPLIANCE
MATERIAL CHARACTERISTICS
• Base Device: cULus listed to UL498 and UL943, file no. E60120;
meets all UL943 (GFCI), UL498 (Receptacles) and applicable CSA
requirements; Hospital Grade versions also meet all UL498 Hospital
Grade requirements; NOM Certified
• ArrowLink: Plug & connector cULus Listed to UL2459 file no. E325188
• Combined: cULus Listed wiring assembly, UL file no. E326691
• Nylon & PVC with adhesive terminal barrier, except Hospital Grade: nylon &
polycarbonate
• Environmental, Base Device: Flammability meets UL 94 requirements; V2 rated;
temperature rating: -35ºC to 66ºC (-31ºF to 150.8ºF)
• Environmental, ArrowLink: Flammability meets UL 94 requirements; V2 rated;
temperature rating: -20ºC to 90ºC (-4ºF to 194ºF) max.
19
Modular GFCI Receptacles
Specification & Performance Data
Project Name:
Prepared By:
Project Number:
Date:
Catalog Number:
Type:
Ground Fault Circuit
Interrupters
2-Pole, 3-Wire Grounding
15A 125V
20A 125V
Application
GFCI receptacles are designed with the safety of the user in mind. In commercial and industrial areas like public bathrooms, breakrooms
and food service areas, the NEC® requires GFCI receptacles. Arrow Hart ArrowLink GFCI receptacles are UL Listed and fully compliant with
all of the latest UL943 (4th Edition) Class A GFCI and UL498 requirements. Additionally, ArrowLink GFCIs incorporate our ShockSentry™
lock-out function to protect against mis-wired line-load connections and GFCI circuitry damage. Safety barriers provide insulation from
conductive surfaces. Patent-pending modular plug and connector provide consistent high quality circuit connections and reduce overall
installation time on the job.
Receptacle Type
Wiring Type
Tamper Resistant Hospital Grade GFCI Duplex
Receptacle TRVGFH15_M, TRVGFH20_M Series;
Hospital Grade GFCI Duplex Receptacle VGFH15_M,
VGFH20_M Series; ArrowLink: MCR125_Series
Tamper Resistant
Base Device: Back & side wire
ArrowLink: Integral wire leads, crimped & resistance welded
Testing & Code Compliance
Base Device
• cULus listed to UL498 and UL943, file no. E60120
• Meets all UL943 (GFCI), UL498 (Receptacles), UL498 Hospital
Grade and applicable CSA requirements
• NOM Certified
Tamper Resistant
Base Device: Back & side wire
ArrowLink: Integral wire leads, crimped & resistance welded
• cULus listed to UL498 and UL943, file no. E60120
• Meets all UL943 (GFCI), UL498 (Receptacles) and applicable CSA
requirements
• NOM Certified
ArrowLink
• Plug & connector cULus Listed to UL2459 file no. E325188
• Plug & connector cULus Listed to UL2459 file no. E325188
Combined
• cULus Listed wiring assembly, UL file no. E326691
• cULus Listed wiring assembly, UL file no. E326691
Flammability meets UL 94 requirements; V2 rated
Temperature rating: -35ºC to 66ºC (-31ºF to 150.8ºF)
Flammability meets UL 94 requirements; V2 rated
Temperature rating: -35ºC to 66ºC (-31ºF to 150.8ºF)
Environmental,
ArrowLink
Flammability meets UL 94 requirements; V2 rated
Temperature rating:-20ºC to 90ºC (-4ºF to 194ºF) max.
Flammability meets UL 94 requirements; V2 rated
Temperature rating: -20ºC to 90ºC (-4ºF to 194ºF) max.
Electrical, Base Device
Dielectric Voltage: withstands 2000V per UL498
Temperature Rise: max. 30ºC (86°F) after 100 cycles of overload @
150% of rated current (DC)
Trip Time: .025 seconds (class A)
Frequency: 60 Hz; Voltage: 125 V; Amperage: 15A/20A
20A Feed Thru
Maximum Interrupting Capacity: 20 amps
Current interrupting: yes, at full-rated current
Dielectric Voltage: withstands 2000V per UL498
Temperature Rise: max. 30ºC (86°F) after 100 cycles of overload @
150% of rated current (DC)
Trip Time: .025 seconds (class A)
Frequency: 60 Hz; Voltage: 125 V; Amperage: 15A/20A
20A Feed Thru
Maximum Interrupting Capacity: 20 amps
Current interrupting: yes, at full-rated current
Electrical, ArrowLink
Maximum working voltage 300V / AC
Overload: 52.5A / AC for 10 cycles
Temperature Rise: Max. 50ºC (122°F) while conducting 35A after 10
cycles of overload @ 52.5A / AC
Dielectric Voltage: withstands 1600V per UL2459
Maximum continuous current: 20A
Current interrupting: limited cycles at full-rated current
Maximum working voltage 300V / AC
Overload: 52.5A / AC for 10 cycles
Temperature Rise: Max. 50ºC (122°F) while conducting 35A after 10
cycles of overload @ 52.5A / AC
Dielectric Voltage: withstands 1600V per UL2459
Maximum continuous current: 20A
Current interrupting: limited cycles at full-rated current
Mechanical
Base Device Terminal Accommodation: #14 - #10 AWG
ArrowLink Wire Leads: #12 AWG
Voltage ratings permanently marked on device
Base Device Terminal Accommodation: #14 - #10 AWG
ArrowLink Wire Leads: #12 AWG
Voltage ratings permanently marked on device
Screw Terminal Guards
Material: UL Recognized Insulating Material
Dielectric Strength: 2,000V Min
HWI Rating: 4 Min.
Relative Temperature Index, Electrical: 80ºC (176ºF)
Flammability: V0 (UL94)
Material: UL Recognized Insulating Material
Dielectric Strength: 2,000V Min
HWI Rating: 4 Min.
Relative Temperature Index, Electrical: 80ºC (176ºF)
Flammability: V0 (UL94)
Specifications:
Environmental,
Base Device
Materials
Top Housing
20
Tamper Resistant Specification Grade GFCI Duplex
Receptacle: TRVGF15_M, TRVGF20_M Series;
Specification Grade GFCI Duplex Receptacle:
VGF15_M, VGF20_M Series; ArrowLink: MCR125_ Series
Thermoplastic, nylon
Thermoplastic, nylon
Bottom Housing
Polycarbonate
PVC
Strap
0.047" thick steel, zinc plated
0.047" thick steel, zinc plated
Terminals
Brass
Brass
Terminal & Ground
Screws
#8-32 steel, brass plated; neutral screw nickel plated, ground screw
green
#8-32 steel, brass plated; neutral screw nickel plated, ground screw
green
ArrowLink Housing
Polycarbonate
Polycarbonate
ArrowLink Contacts
Copper alloy
Copper alloy
ArrowLink Wire Leads
Solid or stranded THHN #12 AWG
Solid or stranded THHN #12 AWG
Modular Isolated Ground
Project Name:
Prepared By:
Project Number:
Date:
Catalog Number:
Type:
Isolated Ground Straight
Blade Receptacles
2-Pole, 3-Wire Grounding
15A 125V
20A 125V
1.32"
(33.5mm)
Duplex Isolated Ground Receptacles
FEATURES
• ArrowLink modular plug and connector provide
high quality circuit connections and incorporate a
first make/last break grounding design.
• Wire leads are crimped and resistance welded
to plug and connector terminals for maximum
durability.
• Audible “click” when mating plug and connector
indicates proper assembly during final device
installation.
• Pre-wired plugs provide 100% inspected and
consistent torque settings for reliable connections
to base devices.
• Connectors shipped with re-usable protective
covering that allows circuit testing while
protecting the connection from foreign matter.
• Exclusive screw terminal guards provide a
protective barrier from conductive surfaces.
• Exclusive 5-leaf, brass line contacts ensure lowest
heat rise, smooth plug blade insertion, long-term
retention and corrosion resistance.
• Rigid, glass reinforced nylon base lends ultimate
strength and superior high heat resistance in
contact carrier.
• High impact and chemical-resistant nylon face.
• Decorator models have 0.050" (1.27mm) solid
brass, nickel-plated mounting strap with nonriveted, integral one-piece isolated grounding shunt
system for highest durability – assures superior
ground integrity and corrosion resistance under
heaviest use.
• Traditional style duplex models have 0.030"
(0.76mm) solid brass, non-riveted, integral onepiece isolated grounding shunt system assures
ground integrity under heaviest use – isolated from
common building ground.
• Long, broad mounting strap helps reach large panel
cutouts for code compliance.
• Screw-Catch™ feature on traditional style duplex
devices speeds mounting of wallplates.
3.28"
(83.3mm)
F
Rating
A V
15 125
NEMA
5-15R
Description
Hospital Decorator IG Modular Receptacle
I IG8262___M
Available
Colors
GY, RN, V, W
20 125
5-20R
Hospital Decorator IG Modular Receptacle
I IG8362___M
GY, RN, V, W
R
Depth with
ArrowLink
1.31"
(33.2mm)
IG8262_M
1.30"
(33.0mm)
4.19"
(106.4mm)
3.28"
(83.3mm)
IG5362_M
Back Wire and Side Wire – 1 Piece Brass Ground System
Catalog No.
4.19"
(106.4mm)
Depth with
ArrowLink
1.31"
(33.2mm)
S
1.42"
(36.1mm)
Lead
Length:
6.00”
(152.4mm)
0.40"
(10.2mm)
1.08"
(27.4mm)
Back Wire and Side Wire – Brass Ground Shunt
Rating
A V
15 125
20 125
F
Catalog No.
NEMA
5-15R
5-20R
R
Receptacle
Connector
S
Description
Hospital Duplex IG Modular Receptacle
I IG8200___M
Available
Colors
GY, RD, RN, V, W
Duplex IG Modular Receptacle
I IG5262___M
GY, RD, RN, V, W
Hospital Duplex IG Modular Receptacle
I IG8300___M
GY, RD, RN, V, W
Duplex IG Modular Receptacle
I IG5362___M
BK, GY, RD, RN, V, W
1.42"
(36.1mm)
0.40"
(10.2mm)
Receptacle
Plug
For ordering, include Cat. No. followed by the color code: BK (Black), GY (Gray), RN (Orange), RD (Red), V (Ivory), W (White)
ArrowLink Receptacle Connectors
C
Description
Catalog No.
ArrowLink Modular Receptacle 125V Building Wire Connector, Solid Wire
I MCR125SOL
ArrowLink Modular Receptacle 125V Building Wire Connector, Stranded Wire
I MCR125STR
Patent Pending
R
1.08"
(27.4mm)
US
G
5-15R
W
G
W
5-20R
For Specification & Performance
Data, see page 22.
TESTING & CODE COMPLIANCE
MATERIAL CHARACTERISTICS
• Base Device: UL Listed to UL498, file no E15058; UL verified
to Federal Spec. WC-596G; CSA Certified to C22.2, no. 42,
file no. 6914, class 6233-01
• ArrowLink: Plug & connector cULus Listed to UL2459 file no.
E325188
• Combined: cULus Listed wiring assembly, UL file no. E326691
• Nylon with PVC terminal guards, except Hospital Grade: nylon terminal guards
• Environmental, Base Device: Flammability meets UL 94 requirements; V2 rated; temperature
rating: -20ºC to 70ºC (-4ºF to 158ºF), except IG8200_M & IG8300_M: -40ºC to 60ºC (-40ºF
to 140ºF)
• Environmental, ArrowLink: Flammability meets UL 94 requirements; V2 rated; temperature
rating: -20ºC to 90ºC (-4ºF to 194ºF) max.
21
Modular Isolated Ground
Receptacles Specification &
Performance Data
Project Name:
Prepared By:
Project Number:
Date:
Catalog Number:
Type:
Isolated Ground Straight
Blade Receptacles
2-Pole, 3-Wire Grounding
15A 125V
20A 125V
Application
The grounding network in any commercial building protects both people and equipment. It can also conduct electromagnetic interference,
or electronic noise which distorts electronic signals and causes sensitive electronic equipment to operate improperly. In commercial
facilities, the transfer of reliable, undistorted information is crucial to daily business. ArrowLink Isolated Ground Straight Blade Receptacles
utilize our exclusive solid brass, non-riveted, integral one-piece isolated grounding shunt system to assure ground integrity under the
heaviest use. Patent-pending modular plug and connector provide high quality circuit connections and reduce overall installation time.
Receptacle Type
Hospital Grade Decorator Duplex
Isolated Ground: IG8262_M, IG8362_M
Series; ArrowLink: MCR125_ Series
Hospital Grade Duplex
Isolated Ground: IG8200_M, IG8300_M
Series; ArrowLink: MCR125_ Series
Industrial Grade Duplex
Isolated Ground: IG5262_M, IG5362_M
Series; ArrowLink: MCR125_ Series
Wiring Type
Base Device: Back & side wire
ArrowLink: Integral wire leads, crimped &
resistance welded
• UL Listed to UL498, file no E15058
• UL verified to Federal Spec. WC-596G
• CSA Certified to C22.2, no. 42, file no.
6914, class 6233-01
Base Device: Back & side wire
ArrowLink: Integral wire leads, crimped &
resistance welded
• UL Listed to UL498, file no E15058
• UL verified to Federal Spec. WC-596G
• CSA Certified to C22.2, no. 42, file no.
6914, class 6233-01
Base Device: Back & side wire
ArrowLink: Integral wire leads, crimped &
resistance welded
• UL Listed to UL498, file no E15058
• UL verified to Federal Spec. WC-596G
• CSA Certified to C22.2, no. 42, file no.
6914, class 6233-01
ArrowLink • Plug & connector cULus Listed to UL2459
file no. E325188
• Plug & connector cULus Listed to UL2459
file no. E325188
• Plug & connector cULus Listed to UL2459
file no. E325188
Combined • cULus Listed wiring assembly, UL file no.
E326691
• cULus Listed wiring assembly, UL file no.
E326691
• cULus Listed wiring assembly, UL file no.
E326691
Flammability meets UL 94 requirements; V2
rated
Temperature rating: -20ºC to 70ºC (-4ºF to
158ºF)
Flammability meets UL 94 requirements; V2
rated
Temperature rating: -40ºC to 60ºC (-40ºF to
140ºF)
Flammability meets UL 94 requirements; V2
rated
Temperature rating: -20ºC to 70ºC (-4ºF to
158ºF)
Environmental,
ArrowLink
Flammability meets UL 94 requirements; V2
rated
Temperature rating: -20ºC to 90ºC (-4ºF to
194ºF) max.
Flammability meets UL 94 requirements; V2
rated
Temperature rating: -20ºC to 90ºC (-4ºF to
194ºF) max.
Flammability meets UL 94 requirements; V2
rated
Temperature rating: -20ºC to 90ºC (-4ºF to
194ºF) max.
Electrical, Base Device
Dielectric Voltage: withstands 2000V per
UL498
Temperature Rise: max. 30ºC (86°F) after 250
cycles of overload @ 200% of rated
current (DC)
Current interrupting: yes, at full-rated current
Dielectric Voltage: withstands 2000V per
UL498
Temperature Rise: max. 30ºC (86°F) after 250
cycles of overload @ 200% of rated
current (DC)
Current interrupting: yes, at full-rated current
Dielectric Voltage: withstands 2000V per
UL498
Temperature Rise: max. 30ºC (86°F) after 250
cycles of overload @ 200% of rated
current (DC)
Current interrupting: yes, at full-rated current
Electrical, ArrowLink
Maximum working voltage 300V / AC
Overload: 52.5A / AC for 10 cycles
Temperature Rise: Max. 50ºC (122°F) while
conducting 35A after 10 cycles of overload
@ 52.5A / AC
Dielectric Voltage: withstands 1600V per
UL2459
Maximum continuous current: 20A
Current interrupting: limited cycles at fullrated current
Maximum working voltage 300V / AC
Overload: 52.5A / AC for 10 cycles
Temperature Rise: Max. 50ºC (122°F) while
conducting 35A after 10 cycles of overload
@ 52.5A / AC
Dielectric Voltage: withstands 1600V per
UL2459
Maximum continuous current: 20A
Current interrupting: limited cycles at fullrated current
Maximum working voltage 300V / AC
Overload: 52.5A / AC for 10 cycles
Temperature Rise: Max. 50ºC (122°F) while
conducting 35A after 10 cycles of overload
@ 52.5A / AC
Dielectric Voltage: withstands 1600V per
UL2459
Maximum continuous current: 20A
Current interrupting: limited cycles at fullrated current
Mechanical
Base Device Terminal Accommodation: #14 #10 AWG
ArrowLink Wire Leads: #12 AWG
Voltage ratings permanently marked on
device
Base Device Terminal Accommodation: #14 #10 AWG
ArrowLink Wire Leads: #12 AWG
Voltage ratings permanently marked on
device
Base Device Terminal Accommodation: #14 #10 AWG
ArrowLink Wire Leads: #12 AWG
Voltage ratings permanently marked on
device
Screw Terminal Guards
Material: Nylon hinged doors
Material: PVC hinged doors
Material: PVC hinged doors
Testing & Code
Compliance
Base
Device
Specifications:
Environmental,
Base Device
Materials
Top Housing
22
Thermoplastic, nylon
Thermoplastic, nylon
Thermoplastic, nylon
Bottom Housing
Glass-filled nylon
Glass-filled nylon
Glass-filled nylon
Strap & Isolated Ground
Contact
Strap 0.05" galvanized steel; ground shunt
0.05" solid brass, one piece
Strap 0.05" galvanized steel; ground shunt
0.05" solid brass, one piece
Strap 0.05" galvanized steel; ground shunt
0.05" solid brass, one piece
Auto Ground Clip
Brass
Brass
Brass
Line Contacts
0.032" 5-leaf brass
0.032" 5-leaf brass
0.032" 5-leaf brass
Terminal & Ground
Screws
#8-32 brass, neutral screw nickel plated,
ground screw green
#8-32 brass, neutral screw nickel plated,
ground screw green
#8-32 brass, neutral screw nickel plated,
ground screw green
ArrowLink Housing
Polycarbonate
Polycarbonate
Polycarbonate
ArrowLink Contacts
Copper alloy
Copper alloy
Copper alloy
ArrowLink Wire Leads
Solid or stranded THHN #12 AWG
Solid or stranded THHN #12 AWG
Solid or stranded THHN #12 AWG
Modular TVSS Receptacles
Project Name:
Prepared By:
Project Number:
Date:
Catalog Number:
Type:
TVSS Straight Blade
Receptacles
2-Pole, 3-Wire Grounding
15A 125V
20A 125V
1.31"
(33.3mm)
Duplex TVSS Receptacles with LED Indicators & Switched Alarm
FEATURES
• ArrowLink modular plug and connector provide
high quality circuit connections and incorporate a
first make/last break grounding design.
• Wire leads are crimped and resistance welded
to plug and connector terminals for maximum
durability.
• Audible “click” when mating plug and connector
indicates proper assembly during final device
installation.
• Pre-wired plugs provide 100% inspected and
consistent torque settings for reliable connections
to base devices.
• Connectors shipped with re-usable protective
covering that allows circuit testing while
protecting the connection from foreign matter.
• Exclusive screw terminal guards provide a
protective barrier from conductive surfaces.
• Provides surge protection for hot to neutral and
hot to ground.
• High impact thermoplastic construction.
• Shallow depth for easy installation.
• Green LED indicators to verify surge protection
and ground.
• Audible alarm indicates bad ground connection or
expired surge protection.
• Front access switch for muting audible alarm until
device is replaced.
I 8200___SM
Available
Colors
BL, GY, V, W
I IG8200HG___SM
BL, GY, RN, V, W
TVSS Modular Receptacle
I 5262___SM
BL, GY, V, W
Isolated Ground TVSS Modular Receptacle
I IG5262___SM
BL, RN, W
Hospital TVSS Modular Receptacle
I 8300___SM
BL, GY, RD, V, W
I IG8300HG___SM
BL, GY, RN, V, W
TVSS Modular Receptacle
I 5362___SM
BL, GY, V, W
Isolated Ground TVSS Modular Receptacle
I IG5362___SM
BL, GY, RN, V, W
Description
Hospital TVSS Modular Receptacle
Hospital Isolated Ground TVSS
Modular Receptacle
20 125
5-20R
2.69"
(68.3mm)
Depth with
ArrowLink
1.64"
(41.7mm)
IG8200HG_SM
1.31"
(33.3mm)
3.28"
(83.3mm)
Catalog No.
NEMA
5-15R
3.28"
(83.3mm)
3.81"
(96.8mm)
Hospital and Commercial Grade - Back Wire and Side Wire
Rating
A V
15 125
3.81"
(96.8mm)
Hospital Isolated Ground TVSS
Modular Receptacle
2.69"
(68.3mm)
5362_SM
Depth with
ArrowLink
1.64"
(41.6mm)
1.42"
(36.1mm)
Lead
Length:
6.00”
(152.4mm)
0.40"
(10.2mm)
1.08"
(27.4mm)
Receptacle
Connector
1.42"
(36.1mm)
For ordering, include Cat. No. followed by the color code: BL (Blue), GY (Gray), RN (Orange), RD (Red), V (Ivory), W (White)
0.40"
(10.2mm)
1.08"
(27.4mm)
ArrowLink Receptacle Connectors
C
Description
Catalog No.
ArrowLink Modular Receptacle 125V Building Wire Connector, Solid Wire
I MCR125SOL
ArrowLink Modular Receptacle 125V Building Wire Connector, Stranded Wire
I MCR125STR
R
US
Receptacle
Plug
G
Patent Pending
5-15R
W
G
W
5-20R
For Specification & Performance
Data, see page 24.
TESTING & CODE COMPLIANCE
MATERIAL CHARACTERISTICS
• Base Device: UL listed to UL498 and UL1449, file no. E2369;
CSA Certified to C22.2, no. 42, file no. 700227, except
Hospital Grade: file no. 7087
• ArrowLink: Plug & connector cULus Listed to UL2459 file no.
E325188
• Combined: cULus Listed wiring assembly, UL file no. E326691
• Nylon with adhesive terminal barrier
• Environmental, Base Device: Flammability meets UL 94 requirements; V2 rated; temperature
rating: -20ºC to 60ºC (-4ºF to 140ºF), except Hospital Grade: -40ºC to 60ºC (-40ºF to 140ºF)
• Environmental, ArrowLink: Flammability meets UL 94 requirements; V2 rated; temperature
rating: -20ºC to 90ºC (-4ºF to 194ºF) max.
23
Modular TVSS Receptacles
Specification & Performance Data
Project Name:
Prepared By:
Project Number:
Date:
Catalog Number:
Type:
TVSS Straight Blade
Receptacles
2-Pole, 3-Wire Grounding
15A 125V
20A 125V
Application
Commercial buildings and industrial facilities are filled with sensitive electronic equipment that businesses depend on for the function of
critical daily operations. Substantial transient voltage can be initiated from external lighting strikes and grid switching, but the majority of
transients are created within a facility. Arrow Hart ArrowLink TVSS Receptacles are manufactured from high impact thermoplastics and
boast exceptional clamping and surge current ratings. They are available in isolated ground and non-isolated ground with optional audible
alarm to indicate bad ground connection or expired surge protection. Safety barriers provide insulation from conductive surfaces. Patentpending modular plug and connector provide consistent high quality circuit connections and reduce overall installation time on the job.
Receptacle Type
Hospital Grade Isolated Ground Duplex TVSS Receptacle:
IG8200HG_SM, IG8300HG_SM Series; Hospital Grade Duplex
TVSS Receptacle: 8200_SM, 8300_SM Series;
ArrowLink: MCR125_Series
Commercial Specification Grade Isolated Ground Duplex
TVSS Receptacle: IG5262_SM,IG5362_SM Series;
Commercial Specification Grade Duplex TVSS Receptacle:
5262_SM, 5362_SM Series; ArrowLink: MCR125_ Series
Wiring Type
Base Device: Back & side wire
ArrowLink: Integral wire leads, crimped & resistance welded
Base Device: Back & side wire
ArrowLink: Integral wire leads, crimped & resistance welded
Testing & Code Compliance
Base Device
• UL listed to UL498 and UL1449, file no. E2369
• CSA Certified to C22.2, no. 42, file no. 7087
ArrowLink
• Plug & connector cULus Listed to UL2459 file no. E325188
• Plug & connector cULus Listed to UL2459 file no. E325188
Combined
• cULus Listed wiring assembly, UL file no. E326691
• cULus Listed wiring assembly, UL file no. E326691
Flammability meets UL 94 requirements; V2 rated
Temperature rating: -40ºC to 60ºC (-40ºF to 140ºF)
Flammability meets UL 94 requirements; V2 rated
Temperature rating: -20ºC to 60ºC (-4ºF to 140ºF)
Environmental,
ArrowLink
Flammability meets UL 94 requirements; V2 rated
Temperature rating: -20ºC to 90ºC (-4ºF to 194ºF) max.
Flammability meets UL 94 requirements; V2 rated
Temperature rating: -20ºC to 90ºC (-4ºF to 194ºF) max.
Electrical, Base Device
Dielectric Voltage: withstands 2000V per UL498
Temperature Rise: max. 30ºC (86°F) after 100 cycles of overload @
150% of rated current (DC)
Clamping voltage: 400V; Joules/MCOV: 280J/150V/AC RMS
Maximum Surge Current: 18kA per mode
Current interrupting: yes, at full-rated current
Dielectric Voltage: withstands 2000V per UL498
Temperature Rise: max. 30ºC (86°F) after 100 cycles of overload @
150% of rated current (DC)
Clamping voltage: 400V; Joules/MCOV: 280J/150V/AC RMS
Maximum Surge Current: 18kA per mode
Current interrupting: yes, at full-rated current
Electrical, ArrowLink
Maximum working voltage 300V / AC
Overload: 52.5A / AC for 10 cycles
Temperature Rise: Max. 50ºC (122°F) while conducting 35A after 10
cycles of overload @ 52.5A / AC
Dielectric Voltage: withstands 1600V per UL2459
Maximum continuous current: 20A
Current interrupting: limited cycles at full-rated current
Maximum working voltage 300V / AC
Overload: 52.5A / AC for 10 cycles
Temperature Rise: Max. 50ºC (122°F) while conducting 35A after 10
cycles of overload @ 52.5A / AC
Dielectric Voltage: withstands 1600V per UL2459
Maximum continuous current: 20A
Current interrupting: limited cycles at full-rated current
Mechanical
Base Device Terminal Accommodation: #14 - #10 AWG
ArrowLink Wire Leads: #12 AWG
Voltage ratings permanently marked on device
Green LED indicators to verify surge protection and ground
Audible alarm indicates compromised connection or surge protection
has expired
Front access switch for muting audible alarm until device is replaced
Base Device Terminal Accommodation: #14 - #10 AWG
ArrowLink Wire Leads: #12 AWG
Voltage ratings permanently marked on device
Green LED indicators to verify surge protection and ground
Screw Terminal Guards
Material: UL Recognized Insulating Material
Dielectric Strength: 2,000V Min
HWI Rating: 4 Min.
Relative Temperature Index, Electrical: 80ºC (176ºF)
Flammability: V0 (UL94)
Material: UL Recognized Insulating Material
Dielectric Strength: 2,000V Min
HWI Rating: 4 Min.
Relative Temperature Index, Electrical: 80ºC (176ºF)
Flammability: V0 (UL94)
Specifications:
Environmental,
Base Device
Materials
Top Housing
24
• UL listed to UL498 and UL1449, file no. E2369
• CSA Certified to C22.2, no. 42, file no. 700227
Thermoplastic, nylon
Thermoplastic, nylon
Bottom Housing
Nylon
Nylon
Strap
0.05" thick steel, zinc plated with gold chromate
0.05" thick steel, zinc plated with gold chromate
Line Contacts
0.037" triple wipe brass
Brass
Terminal & Ground
Screws
#8-32 brass; neutral screw nickel plated, ground screw green
#8-32 brass; neutral screw nickel plated, ground screw green
ArrowLink Housing
Polycarbonate
Polycarbonate
ArrowLink Contacts
Copper alloy
Copper alloy
ArrowLink Wire Leads
Solid or stranded THHN #12 AWG
Solid or stranded THHN #12 AWG
Modular Switches
Project Name:
Prepared By:
Project Number:
Date:
Catalog Number:
Type:
Industrial Grade Toggle
Switches
AC Quiet Switches
15A 120/277V/AC
20A 120/277V/AC
1.31"
(33.3mm)
Industrial Grade AC Quiet Toggle Switches
FEATURES
• ArrowLink modular plug and connector provide
high quality circuit connections and incorporate a
first make/last break grounding design.
• Wire leads are crimped and resistance welded
to plug and connector terminals for maximum
durability.
• Audible “click” when mating plug and connector
indicates proper assembly during final device
installation.
• Pre-wired plugs provide 100% inspected and
consistent torque settings for reliable connections
to base devices.
• Connectors shipped with re-usable protective
covering that allows circuit testing while
protecting the connection from foreign matter.
• Exclusive screw terminal guards provide a
protective barrier from conductive surfaces.
• Industrial design cam action mechanism insures
quiet switch action.
• Color-coded faces identify amperage: blue=15
amp, red=20 amp.
• 0.050" (1.27mm) thick steel mounting strap, zincplated for corrosion resistance.
• 120/277V/AC rating ideal for fluorescent lighting
fixtures typical in commercial applications.
• Lighted version toggle glows when in the off
position.
• 277V versions available with different lead color
combinations for local color coding requirements
(standard lead colors are black, black, and green
for Line (LI)/Load (LO)/Ground ( ) sequence).
Industrial Grade - Back and Side Wire
Rating
A
V/AC
15 120/277
20
120/277
C
Catalog No.
R
US
F
I AH1201___M*
Modular Single Pole Lighted Toggle Switch
I AH1201LT___M* V, W
Modular Single Pole Toggle Switch
I AH1221___M*
Modular Single Pole Lighted Toggle Switch
I AH1221LT___M* V, W
ArrowLink Modular Switch 120V
Building Wire Connector, Solid Wire
ArrowLink Modular Switch 120V
Building Wire Connector, Stranded Wire
ArrowLink Modular Switch 277V
Building Wire Connector, Solid Wire
ArrowLink Modular Switch 277V
Building Wire Connector, Stranded Wire
1.31"
(33.2mm)
3.28"
(83.3mm)
2.40"
(61.0mm)
2.38"
(60.5mm)
426
AH1221LT_M
C
Catalog No.
Depth with
ArrowLink
1.50"
(38.1mm)
AH1201_M
B, BK, GY, LA, RD, V, W
ArrowLink Switch Connectors
2.40"
(61.0mm)
2.38"
(60.5mm)
Available
Colors
B, GY, RD, V, W
Description
Modular Single Pole Toggle Switch
Description
S
R
3.28"
(83.3mm)
R
Depth with
ArrowLink
1.50"
(38.1mm)
Lead Color Configuration
US
I MCS120SOL
Lead Color Sequence
(Line/Load/Ground)
Black, Black, Green
I MCS120STR
Black, Black, Green
I MCS277SOL*
Black, Black, Green
0.52"
(13.2mm)
I MCS277STR*
Black, Black, Green
1.08"
Switch (27.4mm)
Connector
(enlarged)
1.03"
(26.2mm)
Lead
Length:
6.00”
(152.4mm)
1.03"
(26.2mm)
Patent Pending
For ordering devices, include Cat. No. followed by the color code: B (Brown), BK (Black), GY (Gray), LA (Light Almond), RD
(Red), V (Ivory), W (White)
* For custom 277V lead color combinations, include Cat. No. followed by 3 color code indicators, one for each lead, in the
Line (LI)/Load (LO)/Ground ( ) sequence: B (Brown), E (Green), G (Gray), K (Black), L (Blue), N (Orange), P (Pink), R (Red),
Y (Yellow); ex. Switch AH1221VMYBE or Connector MCS277SOLYBE (“Y” Yellow, “B” Brown, “E” Green)
** Lead color sequences other than Black/Black/Green for switches or connectors will add 2 days to the lead times on page 7
0.52"
(13.2mm)
Switch
Plug
1.08"
(27.4mm)
For Specification & Performance
Data, see page 27.
TESTING & CODE COMPLIANCE
MATERIAL CHARACTERISTICS
• Base Device: cULus Listed to UL20, file no. E18704, except
AH1221: UL Listed; UL verified to Federal Spec. WS-896;
NOM Certified
• ArrowLink: Plug & connector cULus Listed to UL2459 file no.
E325188
• Combined: cULus Listed wiring assembly, UL file no. E326691
• Polycarbonate & thermoset with adhesive terminal barrier
• Environmental, Base Device: Flammability meets UL 94 requirements; V2 rated;
temperature rating: -20ºC to 65ºC (-4ºF to 149ºF)
• Environmental, ArrowLink: Flammability meets UL 94 requirements; V2 rated;
temperature rating: -20ºC to 90ºC (-4ºF to 194ºF) max.
25
Modular Switches
Project Name:
Prepared By:
Project Number:
Date:
Catalog Number:
Type:
Commercial Grade
Decorator Switches
AC Quiet Switches
15A 120/277V/AC
20A 120/277V/AC
Commercial Grade AC Quiet Decorator Switches
1.44"
(36.5mm)
3.81"
(96.8mm)
2.60"
(66.0mm)
3.28"
(83.3mm)
Depth with
ArrowLink
1.69"
(42.9mm)
7621_M
FEATURES
• ArrowLink modular plug and connector provide
high quality circuit connections and incorporate a
first make/last break grounding design.
• Wire leads are crimped and resistance welded
to plug and connector terminals for maximum
durability.
• Audible “click” when mating plug and connector
indicates proper assembly during final device
installation.
• Pre-wired plugs provide 100% inspected and
consistent torque settings for reliable connections
to base devices.
• Connectors shipped with re-usable protective
covering that allows circuit testing while
protecting the connection from foreign matter.
• Exclusive screw terminal guards provide a
protective barrier from conductive surfaces.
• Welded construction provides superior assembly
security under heavy use.
• One-piece color-coded wrap-around mounting
straps assure ground integrity and provide a quick
visual amperage indicator for durable, safe and
reliable installations.
• Smooth face for ease of cleaning.
• 277V versions available with different lead color
combinations for local color coding requirements
(standard lead colors are black, black, and green
for Line (LI)/Load (LO)/Ground ( ) sequence).
Commercial Grade - Back and Side Wire
Lead Color Configuration
C
US F
Switch Rating
A
V/AC
Description
15
120/277
Modular Single Pole Decorator Switch
I 7601___M*
A, B, BK, GY, LA, V, W
20
120/277
Modular Single Pole Decorator Switch
I 7621___M*
A, B, BK, GY, LA, RD, V, W
I 7631___M*
A, LA, V, W
(enlarged)
Catalog No.
R
Modular Single Pole Lighted
Decorator Switch
AVAILABLE
Q2 2009!
1.03"
(26.2mm)
ArrowLink Modular Switch 120V
Building Wire Connector, Solid Wire
Lead
Length:
6.00”
(152.4mm)
0.52"
(13.2mm)
1.08"
Switch (27.4mm)
Connector
ArrowLink Modular Switch 120V
Building Wire Connector, Stranded Wire
ArrowLink Modular Switch 277V
Building Wire Connector, Solid Wire
ArrowLink Modular Switch 277V
Building Wire Connector, Stranded Wire
1.03"
(26.2mm)
0.52"
(13.2mm)
Switch
Plug
1.08"
(27.4mm)
C
Catalog No.
S
Available
Switch Colors
ArrowLink Switch Connectors
Description
R
R
I MCS120SOL
Lead Color Sequence
(Line/Load/Ground)
Black, Black, Green
I MCS120STR
Black, Black, Green
I MCS277SOL*
Black, Black, Green
I MCS277STR*
Black, Black, Green
US
Patent Pending
For ordering, include Cat. No. followed by the color code: A (Almond), B (Brown), BK (Black), GY (Gray), LA (Light Almond), RD
(Red), V (Ivory), W (White)
* For custom 277V lead color combinations, include Cat. No. followed by 3 color code indicators, one for each lead, in the
Line (LI)/Load (LO)/Ground ( ) sequence: B (Brown), E (Green), G (Gray), K (Black), L (Blue), N (Orange), P (Pink), R (Red),
Y (Yellow); ex. Switch AH1221VMYBE or Connector MCS277SOLYBE (“Y” Yellow, “B” Brown, “E” Green)
For Specification & Performance
Data, see page 27.
** Lead color sequences other than Black/Black/Green for switches or connectors will add 2 days to the lead times on page 7
TESTING & CODE COMPLIANCE
MATERIAL CHARACTERISTICS
• Base Device: cULus Listed to UL20, file no. E18704; UL
verified to Federal Spec. WS-896
• ArrowLink: Plug & connector cULus Listed to UL2459 file no.
E325188
• Combined: cULus Listed wiring assembly, UL file no. E326691
• Polycarbonate with adhesive terminal barrier
• Environmental, Base Device: Flammability meets UL 94 requirements; V0 rated; temperature
rating: -20ºC to 60ºC (-4ºF to 140ºF)
• Environmental, ArrowLink: Flammability meets UL 94 requirements; V2 rated; temperature
rating: -20ºC to 90ºC (-4ºF to 194ºF) max.
26
Modular Switches
Specification & Performance Data
Project Name:
Prepared By:
Project Number:
Date:
Catalog Number:
Type:
Industrial & Commercial
Grade Switches
2-Pole, 3-Wire Grounding
15A 125V
20A 125V
Application
Switches are an integral part of a building’s electrical infrastructure that provides users with the capability to control the flow of current to a
designated load. Therefore, a switch should be capable of handling the in-rush of current created by the equipment, or load, on that
designated circuit. Cooper Wiring Devices’ line of ArrowLink Modular Switches incorporate the most durable design elements in the industry
and are horsepower rated to handle motor loads. The durable contact designs provide long life and reduce potential heat build up. Safety
barriers provide insulation from conductive surfaces. Patent-pending modular plug and connector provide consistent high quality circuit
connections and reduce overall installation time on the job.
Switch Type
Industrial Grade Toggle: AH1201_M, AH1221_M Series;
ArrowLink: MCS120_, MCS277_ Series
Commercial Grade Decorator: 7600_M Series;
ArrowLink: MCS120_, MCS277_ Series
Wiring Type
Base Device: Back & side wire
ArrowLink: Integral wire leads, crimped & resistance welded
Base Device: Back & side wire
ArrowLink: Integral wire leads, crimped & resistance welded
Testing & Code Compliance
Base Device
•
•
•
ArrowLink
•
cULus Listed to UL20, file no. E18704, except AH1221: UL Listed
UL verified to Federal Spec. WS-896
NOM Certified
• cULus Listed to UL20, file no. E18704
• UL verified to Federal Spec. WS-896
Plug & connector cULus Listed to UL2459 file no. E325188
• Plug & connector cULus Listed to UL2459 file no. E325188
• cULus Listed wiring assembly, UL file no. E326691
• cULus Listed wiring assembly, UL file no. E326691
Flammability meets UL 94 requirements; V2 rated
Temperature rating: -20ºC to 65ºC (-4ºF to 149ºF)
Flammability meets UL 94 requirements; V0 rated
Temperature rating: -20ºC to 60ºC (-4ºF to 140ºF)
Environmental,
ArrowLink
Flammability meets UL 94 requirements; V2 rated
Temperature rating: -20ºC to 90ºC (-4ºF to 194ºF) max.
Flammability meets UL 94 requirements; V2 rated
Temperature rating: -20ºC to 90ºC (-4ºF to 194ºF) max.
Electrical, Base Device
Maximum working voltage 277V/AC
Overload: minimum 4.8 times rated current for 100 cycles
Temperature Rise: max. 30ºC (86°F) after 250 cycles of overload @
200% of rated current (DC)
Max. continuous current: 15A, 20A; Endurance: 50,000 cycles min.
Horsepower rated for motor loads per UL20: 15A @ 120V/AC = 1/2
HP; 15A @ 240V/AC = 2HP; 20A @ 120V/AC = 1 HP; 20A @
240V/AC = 2HP
Maximum working voltage 277V/AC
Overload: minimum 4.8 times rated current for 100 cycles
Temperature Rise: max. 30ºC (86°F) after 250 cycles of overload @
200% of rated current (DC)
Max. continuous current: 15A, 20A; Endurance: 50,000 cycles min.
Horsepower rated for motor loads per UL20: 15A @ 120V/AC = 1/2
HP; 15A @ 240V/AC = 2HP; 20A @ 120V/AC = 1 HP; 20A @
240V/AC = 2HP
Electrical, ArrowLink
Maximum working voltage 300V / AC
Overload: 52.5A / AC for 10 cycles
Temperature Rise: Max. 50ºC (122°F) while conducting 35A after 10
cycles of overload @ 52.5A / AC
Dielectric Voltage: withstands 1600V per UL2459
Maximum continuous current: 20A
Current interrupting: limited cycles at full-rated current
Maximum working voltage 300V / AC
Overload: 52.5A / AC for 10 cycles
Temperature Rise: Max. 50ºC (122°F) while conducting 35A after 10
cycles of overload @ 52.5A / AC
Dielectric Voltage: withstands 1600V per UL2459
Maximum continuous current: 20A
Current interrupting: limited cycles at full-rated current
Mechanical
Base Device Terminal Accommodation: #14 - #10 AWG
ArrowLink Wire Leads: #12 AWG
Voltage ratings permanently marked on device
Base Device Terminal Accommodation: #14 - #10 AWG
ArrowLink Wire Leads: #12 AWG
Voltage ratings permanently marked on device
Screw Terminal Guards
Material: UL Recognized Insulating Material
Dielectric Strength: 2,000V Min
HWI Rating: 4 Min.
Relative Temperature Index, Electrical: 80ºC (176ºF)
Flammability: V0 (UL94)
Material: UL Recognized Insulating Material
Dielectric Strength: 2,000V Min
HWI Rating: 4 Min.
Relative Temperature Index, Electrical: 80ºC (176ºF)
Flammability: V0 (UL94)
Combined
Specifications:
Environmental,
Base Device
Materials
Toggle/Paddle
Polycarbonate
Polycarbonate
Top & Bottom Housing
Thermoset, top is color coded by amperage
Polycarbonate
Strap
0.05" thick galvanized steel
0.05" thick steel, zinc plated, (yellow chromate on 20A)
Auto Ground Clip
Brass
Phosphor bronze
Terminals
Brass
Brass
Terminal & Ground
Screws
#8-32 brass, neutral screw nickel plated, ground screw green
#8-32 steel, brass plated; neutral screw nickel plated, ground screw
green
Contacts
Silver alloy
Silver Alloy
Moveable Contact Arm
Brass
Brass
Pressure Plate
Brass
Brass
Illuminated Models
Long-life neon bulb
Long-life neon bulb
ArrowLink Housing
Polycarbonate
Polycarbonate
ArrowLink Contacts
Copper alloy
Copper Alloy
ArrowLink Wire Leads
Solid or stranded THHN #12 AWG
Solid or stranded THHN #12 AWG
27
Cooper Wiring Devices
United States
203 Cooper Circle
Peachtree City, GA 30269
P: 866-853-4293
F: 800-329-3055
Canada
5925 McLaughlin Road
Mississauga, Ontario, L5R 1B8
P: 800-267-1042
F: 800-761-5748
www.cooperwiringdevices.com
email: custserv@cooperwiringdevices.com • cwdmarketing@cooperindustries.com
Cooper Wiring Devices, Arrow Hart, ArrowLink, ShockSentry and Screw-Catch are valuable trademarks of Cooper Industries
in the U.S. and other countries. You are not permitted to use the Cooper Trademarks without the prior written consent of
Cooper Industries.
©2009 Cooper Industries, Ltd.
Your Authorized Cooper Wiring Devices Distributor is:
Cooper Industries, Ltd.
600 Travis, Ste. 5600
Houston, TX 77002-1001
P: 713-209-8400
www.cooperindustries.com
9-MODDEVBRO-09