Weather Protective and Sound Attenuated

ENCLOSURES
WEATHER
PROTECTIVE and
SOUND ATTENUATED
ENCLOSURES
- three levels of sound attenuation
D40-6 to D175-2
D40-6s to D100-6S
FEATURES
HIGHLY CORROSION RESISTANT
CONSTRUCTION
• Stainless steel flush fitting latches and hinges tested
and proven to withstand extreme conditions of
corrosion
• Zinc plated or stainless steel fasteners
• Body made from 16 gauge steel components treated
with polyester powder coating
TRANSPORTABILITY
These enclosures are of extremely rugged construction
to withstand outdoor exposure and rough handling
common on many construction sites. The sound
deadening material is of a self-extinguishing design.
This range of enclosures are designed on modular
principles with many interchangeable components
permitting on-site repair.
EXCELLENT ACCESS
• Single side access for service and controls
• All non-service sides have removable doors and/or
panels
• Radiator fill access
• Lube oil and coolant drains piped to the exterior of
the enclosure base
• Large cable entry area for installation ease
• Double doors on both sides
• Vertically hinged doors with solid bar door stays to
hold doors in place when open.
Three configurations providing three levels of sound
attenuation
• Level 1 (WP-Industrial)
Weather protective with industrial silencer
- silencer mounted within the main enclosure body.
• Level 2 (WP-Critical)
Weather protective with critical silencer
- silencer mounted in separate upward discharging
radiator hood
• Level 3 (SA)
Weather protective with critical silencer and 100%
lined with sound deadening material
- silencer mounted in separate upward discharging
radiator hood
SECURITY AND SAFETY
• Lockable access doors which give full access to
control panel and breaker
• Cooling fan and battery charging alternator fully
guarded
• Fuel fill, oil fill, and battery can only be reached via
lockable access
• Stub-up area is rodent proof
LEHE0417-00
OPTIONS
• Caterpillar Yellow or white paint
• UL Listed 24 or 48 hour sub base tanks
• Externally mounted emergency stop button
• Seismic certification per applicable building codes:
IBC 2000, IBC 2003, IBC 2006, IBC 2009,
IBC 2012, CBC 2007, CBC 2010
• IBC certifiable for 90 mph wind loading
• Special Seismic Certification OSHPD Pre-Approval
OSP-0321-10 (not available with sub base tanks)
Enclosures
Enclosure Sound Levels
WP-Industrial
Enclosure
Standby
Model
ekW
D40-6
40
D50-6
50
D60-6
60
D80-6
80
D100-6
100
D125-6
125
D150-8
150
D175-2
175
WP-Critical
Enclosure
Standby
Model
ekW
D40-6
40
D50-6
50
D60-6
60
D80-6
80
D100-6
100
D125-6
125
D150-8
150
D175-2
175
SA
Enclosure
Standby
Model
ekW
D40-6
40
D50-6
50
D60-6
60
D80-6
80
D100-6
100
D125-6
125
D150-8
150
D175-2
175
Cooling Air
Flow Rate
3
m /s
1.6
1.6
1.9
3.2
3.6
5.0
5.0
6.0
cfm
3475
3475
3920
6696
7564
10531
10531
12650
Cooling Air
Flow Rate
3
m /s
1.7
1.7
1.8
3.2
3.2
4.2
4.2
5.2
cfm
3602
3602
3899
6696
6696
8899
8899
11018
Cooling Air
Flow Rate
3
m /s
1.7
1.7
1.8
3.2
3.2
4.2
4.2
5.2
cfm
3602
3602
3899
6696
6696
8899
8899
11018
Sound Pressure Levels (dBA) at
1m (3.3ft)
7m (23ft)
15m (50ft)
100% 75% 100% 75% 100% 75%
Load
Load
Load
Load
Load
Load
83.8
82.9
71.9
71.3
65.9
65.3
84.9
83.6
72.4
71.7
66.4
65.7
87.9
86.7
74.5
73.1
68.5
67.1
92.4
91.1
78.8
77.6
72.8
71.6
95.2
93.0
81.2
79.8
75.2
73.8
92.7
91.4
79.6
78.7
73.6
72.7
94.0
92.1
80.5
79.2
74.5
73.2
97.8
97.2
83.4
83.0
77.4
77.0
Sound Pressure Levels (dBA) at
1m (3.3ft)
7m (23ft)
15m (50ft)
100% 75% 100% 75% 100% 75%
Load
Load
Load
Load
Load
Load
78.1
77.5
65.8
65.3
59.8
59.3
78.8
77.9
66.4
65.7
60.4
59.7
83.7
82.5
70.6
69.2
64.6
63.2
89.0
88.1
76.9
76.1
70.9
70.1
89.9
88.8
77.7
76.7
71.7
70.7
88.6
87.2
75.3
74.2
69.3
68.2
90.0
88.0
76.4
74.8
70.4
68.8
93.6
93.3
80.0
79.8
74.0
73.8
Sound Pressure Levels (dBA) at
1m (3.3ft)
7m (23ft)
15m (50ft)
100% 75% 100% 75% 100% 75%
Load
Load
Load
Load
Load
Load
77.8
77.0
65.4
64.6
59.4
58.6
78.7
77.6
66.4
65.2
60.4
59.2
82.1
80.4
69.4
67.4
63.4
61.4
88.4
87.3
75.3
74.1
69.3
68.1
89.1
88.2
76.1
75.0
70.1
69.0
86.9
85.5
73.6
72.4
67.6
66.4
88.1
86.4
74.5
73.1
68.5
67.1
90.1
89.5
76.5
75.9
70.5
69.9
The sound pressure level data shown above is quoted as free field and is for guidance only.
Actual levels produced may vary according to site conditions.
LEHE0417-00
2
Enclosures
Enclosure Dimensions and Weights
Image represents WP-Critical and SA enclosures on skid base only.
Image represents WP-Critical and SA enclosures mounted on optional UL listed sub base tank.
LEHE0417-00
3
Enclosures
Enclosure Dimensions and Weights on Skid Bases
WP Industrial on skid base
Genset
Engine Rating Width 'W' Length 'L' Height 'H'
Weight
Model ekW mm
in
mm
in
mm
in
kg
lb
1117
2463
40
2055 80.9 1590 62.6 1210 2668
50
C4.4
1250 2756
60
80
1437 3167
1110 43.7 2523 99.3 1773 69.8
1492 3289
100
125
1800 3968
3193 125.7 1773 69.8 1875 4133
150
C6.6
175
2016 4444
WP Critical on skid base
Genset
Engine Rating Width 'W' Length 'L' Height 'H'
Weight
Model ekW mm
in
mm
in
mm
in
kg
lb
40
1169 2577
2335 91.9 1570 61.8 1262 2782
50
C4.4
1302 2870
60
1495 3295
80
1110 43.7 2891 113.8 1852 72.9
1550 3416
100
125
1861 4102
3640 143.3 1852 72.9 1936 4267
150
C6.6
175
2077 4578
SA on skid base
Genset
Engine Rating Width 'W' Length 'L' Height 'H'
Weight
Model ekW mm
in
mm
in
mm
in
kg
lb
1175 2590
40
2335 91.9 1570 61.8 1268 2795
50
C4.4
1308 2884
60
80
1504 3316
1110 43.7 2891 113.8 1852 72.9
1559 3437
100
125
1874 4131
3640 143.3 1852 72.9 1949 4297
C6.6
150
175
2090 4608
Note: Weight includes oil and coolant
LEHE0417-00
4
Enclosures
Enclosure Dimensions and Weights on UL Listed Sub Base Tanks
WP Industrial with 24 hour tank
Genset
Engine Rating Width 'W' Length 'L' Height 'H'
Weight
Model ekW mm
in
mm
in
mm
in
kg
lb
40
1533 3380
2726 107.3 2087 82.1 1626 3585
50
C4.4
60
1666 3673
1963 4327
80
1110 43.7 3447 135.7 2258 88.9
2018 4448
100
125
2520 5555
C6.6
4035 158.9 2420 95.3 2595 5720
150
175
2736 6031
WP Industrial with 48 hour tank
Length 'L' Height 'H'
Weight
mm
in
mm
in
kg
lb
1683 3709
2726 107.3 2417 95.1 1776 3914
1816 4002
2176 4796
3447 135.7 2608 102.7
2231 4917
2945 6492
5035 198.2 2706 106.5 3020 6657
3161 6968
WP Critical with 24 hour tank
Genset
Weight
Engine Rating Width 'W' Length 'L' Height 'H'
Model ekW mm
in
mm
in
mm
in
kg
lb
40
1585 3494
2726 107.3 2067 81.4 1678 3699
50
C4.4
1718 3788
60
80
2021 4455
1110 43.7 3447 135.7 2337 92.0
100
2076 4576
125
2581 5689
C6.6
4035 158.9 2499 98.4 2656 5855
150
175
2797 6166
WP Critical with 48 hour tank
Length 'L' Height 'H'
Weight
mm
in
mm
in
kg
lb
1735 3824
2726 107.3 2397 94.4 1828 4029
1868 4117
2234 4924
3447 135.7 2687 105.8
2289 5045
3006 6626
5035 198.2 2785 109.6 3081 6792
3222 7103
SA with 24 hour tank
Genset
Weight
Engine Rating Width 'W' Length 'L' Height 'H'
Model ekW mm
in
mm
in
mm
in
kg
lb
1591 3508
40
2726 107.3 2067 81.4 1684 3713
50
C4.4
60
1724 3801
80
2030 4475
1110 43.7 3447 135.7 2337 92.0
100
2085 4597
125
2594 5719
4035 158.9 2499 98.4 2669 5884
C6.6
150
175
2810 6195
SA with 48 hour tank
Length 'L' Height 'H'
Weight
mm
in
mm
in
kg
lb
1741 3837
2726 107.3 2397 94.4 1834 4042
1874 4130
2243 4945
3447 135.7 2687 105.8
2298 5066
3019 6656
5035 198.2 2785 109.6 3094 6821
3235 7132
Note: Weight includes oil and coolant but not fuel
Ref: WPIA, WPIB, WPIC, WPCA, WPCB, WPCC, SATFBA, SATFBB, SATFBC
Information contained in this publication may be considered confidential. Discretion is recommended when distributing.
Materials and specifications are subject to change without notice.
CAT, CATERPILLAR, their respective logos, “Caterpillar Yellow,” the “Power Edge” trade dress as well as corporate
and product identity used herein, are trademarks of Caterpillar and may not be used without permission.
www.Cat-ElectricPower.com
LEHE0417-00 (04/13)
LEHE0417-00
©2013 Caterpillar
All Rights Reserved.
Printed in U.S.A.
5