2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-0809-5 Name: 6L-809 100: DATE: JAN 19 2006 Time: 5:52:57 PM Operator: JB COLOR: CMYK TCP: 15001 Fluorescent Luminaires Hazardous and Non-Hazardous Typedriver Name: TS name csm no.: 100 6L Description Page No. Application/Selection 810 General Purpose Luminaires VF Vaporgard TM Series 811-813 Non-Metallic Luminaires NFL Series N2MVF 843-845 823-828 Hazardous Area Luminaires CPMVF DMVF eLLB20 Series eLLK Series EVLPF EVF Series EVFDR Series EVFT Illuminator TM Series FVN Series FVS Series nLLK Series US: 1-866-764-5454 STIBOINFO((CRH:66008com:6L:809)) CH0 0 0 0 5 L CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds 814, 815 816-822 855-857 846-848 829-835 858-861 862, 863 839-842 852-854 836-838 849-851 809 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-0810-9 Name: 6L-810 100: DATE: JAN 19 2006 Time: 5:52:57 PM Operator: RB COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 Fluorescent Lighting Luminaires 6L Hazardous and Non-Hazardous Application and Selection Quick Selector Chart Application: ɀ for use in hazardous or non-hazardous areas (as shown in the Quick Selector Chart below) ɀ low operating cost ɀ high light output per watt ɀ low brightness ɀ low glare ɀ uniform light ɀ instant illumination Considerations for Selection: Table 500-3(d) Identification Numbers. Having made the determination that a fluorescent luminaire is required, the remaining selection is the type of luminaire (i.e., number and kind of lamps) and placement of luminaire. To determine the number of luminaires: 1. Determine Cavity Ratios for room, ceiling and floor. 2. Determine Coefficient of Utilization 3. Determine Light Loss 4. Determine Lamp Lumens required = Footcandles x Area Coefficient of Utilization x Light Loss Factor 5. Determine number of luminaires required = Total Lamp Lumens Required Lamp Lumens per Luminaire A more complete explanation of the steps to be followed can be found in the Lighting Selector Guide, pages 665 through 689. Maximum Temperature Deg. C Deg. F 450 842 300 572 280 536 260 500 230 446 215 419 200 392 180 356 165 329 160 320 135 275 120 248 100 212 85 185 Quick Selector Chart Series NEC – Hazardous Area Compliance Lamp Watts Volts No. of Lamps VF Cl. I, Division 2, Groups A,B,C,D NFL Cl. I, Division 2, Groups A,B,C,D 5, 7, 9 120 2 32, 40 120-277V 50-60Hz 1, 2 FVN Cl. I, Division 2, Groups A,B,C,D; Cl. II, Groups F,G; Cl. III 32, 40, 60 120, 277, 220/240 50 or 60 Hz 2, 3 EVF Cl. I, Groups C,D; Cl. II, Groups E,F,G 32, 40, 60, 110 120, 277, 347, 220/240 50 or 60 Hz 1, 2, 3, 4 EVFDR Cl. I, Groups C,D; Cl. II, Groups E,F,G 32, 40, 60, 110 120, 277, 220/240 50 or 60 Hz 2 EVFT Cl. I, Groups B,C,D; Cl. II, Groups E,F,G; Cl. III 39 120, 277, 220/240 50 or 60 Hz 2, 4 FVS Cl. I, Division 2, Groups B,C,D; Cl. II, Groups E,F,G; Cl. III 40 120-277V, 50-60Hz or 347V, 60Hz 2 DMVF Cl. I, Division 2, Groups A,B,C,D; Cl. II, Groups E,F,G; Cl. III; Simultaneous Presence 26, 32 120-277V, 50-60Hz or 347V, 60Hz 2, 3 N2MVF Cl. I, Div. 2, Groups A,B,C,D Class II, Groups F,G Class III; Simultaneous Presence 26, 32 120-277V, 50-60Hz or 347V, 60Hz 2 EVLP Cl. I, Div.1, Groups (B), C, D Cl. II, Groups E, F, G Cl. III; Simultaneous Presence 26, 32 120-277V, 50-60Hz or 347V, 60Hz 2 CPMVF Cl. I, Div. 2, Groups A, B, C, D 26, 32, 42 120-277V, 50-60Hz, 347V 60Hz 2 eLLB 20 Cl. I, Division 2, Groups A,B,C,D; Cl. I, Zone 1, Group IIC; Cl. II, Division 2, Groups F,G 17, 32 120-240V, 50-60Hz 110-230 VDC 2 ELLK Cl. I, Zone I & Div 2 Cl. II, Div 2 32 120-254V 2 nLLK Cl. I, Division 2, Groups A,B,C,D; Cl. I, Zone 2 AEx nA II; Cl. II, Division 2, Groups F,G 17, 32 120-277V, 60Hz 2 810 STIBOINFO((CRH:66008com:6L:810)) CH0 0 5 L - 0 US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds Identification Number T1 T2 T2A T2B T2C T2D T3 T3A T3B T3C T4 T4A T5 T6 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-0811-4 Name: 6L-811 100: DATE: JAN 19 2006 Time: 5:52:58 PM Operator: RB COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 ɀ Cl. I, Div. 2, Groups A,B,C,D* Cl. I, Zone 2 IIC* ɀ Wet Locations ɀ NEMA 3,3R VF Series Vaporgard TM Fluorescent Luminaires 6L ɀ Application: Accessories: VF series Vaporgard fluorescent lighting luminaires are used: ɀ indoors or outdoors in industrial locations where enclosed and gasketed luminaires are required ɀ where the energy efficiency and long life of single twin-tube compact fluorescent lamps are desired ɀ where luminaires may be subject to wet, damp, dirty locations ɀ where vibration and rough usage are a problem ɀ to retrofit existing Vaporgard incandescent luminaires ɀ in tunnels, building entrances, utility rooms, hallways and similar locations ɀ with clear or colored globes to illuminate or mark critical locations or processes ɀ See page 812 for complete listing Luminaire Net Weights: 1-Lamp 2-Lamp Luminaire Luminaire Fixture With Globe & With Globe & Type Guard (lbs.) Guard (lbs.) 5 VFA 43⁄4 VFHF 5 51⁄4 VFHBF 71⁄4 71⁄2 Add for Reflectors (lbs.): Dome 1 30° Angle 1 1⁄2 Deduct (lbs.): P21 Guard Temperature Performance Data: Features: ɀ Compact size and light weight allow adaptation and easy installation in many industrial applications ɀ Cast copper-free aluminum (less than 0.4 of 1% copper) construction and epoxy powder finish provide excellent resistance to corrosion ɀ Variety of mounting arrangements to suit any lighting layout – pendant, ceiling, wall bracket, angle stanchion, through feed, box mount ɀ VFH luminaire components can be installed on existing Vaporgard incandescent components and standard stamped metal boxes ɀ Fixtures available for use with two compact fluorescent lamps. Lamps rated at 5, 7 or 9 watts can be used with all luminaires ɀ Dome and 30° angle reflectors made of bright white Krydon® material provide superior reflectivity. Will not chip, peel, dent, rust or corrode. (Order separately – see page 812) ɀ Glass globes are internally fluted and stippled to reduce glare and provide even light distribution. Exteriors are smooth to shed dust ɀ All luminaires 120 VAC only! ɀ Grounding wire for safety Certifications and Compliances: Class I Lamp Div. 2 5, 7W T3B 9W T3B Max. Ambient 40°C 40°C Supply Wire °C 75°C 75°C Minimum Operating –18°C (0°F) –4°C (25°F) ɀ UL Standard: 1598, 844 ɀ CSA Standard C22.2 No. 137 Dimensions VFHA VFC VFH Standard Materials: ɀ Bodies and guards – copper-free aluminum (less than 0.4 of 1%) ɀ Globes – clear or colored, glass or plastic ɀ Reflectors – Krydon fiberglass-reinforced polyester material VFHF VFHBF VFHT VFA Standard Finishes: ɀ Copper-free aluminum – powder epoxy finish ɀ Krydon material – high reflectance white Electrical Ratings: ɀ Input voltage – 120 VAC, 60 hertz ɀ Wattages: two 5, 7 or 9 watt lamps * All mountings except stanchion. US: 1-866-764-5454 STIBOINFO((CRH:66008com:6L:811)) CH0 0 5 L - 1 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds 811 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-0812-3 Name: 6L-812 100: DATE: JAN 19 2006 Time: 5:52:59 PM Operator: TB VF Series Vaporgard TM Fluorescent Luminaires 6L COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 ɀ Cl. I, Div. 2, Groups A,B,C,D** Cl. I, Zone 2 IIC** ɀ Wet Locations ɀ NEMA 3,3R ɀ Twin-Tube Fluorescent with G24 Clear Glass Globe and P21 Guard (lamps not included) Luminaire Watts Hub Size 1⁄2 2 Lamps, 18 3⁄4 1 watts max. 11⁄4 Pendant Mount Cat. # VFA122GP VFA222GP VFA322GP Ceiling Mount Cat. # VFHF122GP VFHF222GP Wall Mount (w/Box) Cat. # VFHBF122GP VFHBF222GP Wall Mount (No Box) Cat. # VFHT122GP VFHT222GP Angle Stanchion Mount* Cat. # Through Feed Mount Cat. # VFC122GP VFC222GP Box Mount & Retrofit Cat. # VFH122GP VFHA422GP* VF Series with Colored Glass Globes or Plastic Globes. To obtain: ɀ Substitute appropriate globe designation for ‘‘G’’ in above Cat. Nos. ɀ Refer to section 1L for globe designations. Accessories and Components Reflectors Globes Guard For use with glass globes only Dome Cat. # RD71 (Cannot be used with wall mount luminaires) 30°Angle Cat. # RA71 Color Clear Green Blue Red Amber Glass Cat. # G24 G25 G26 G27 G28 Plastic Cat. * G63 G65 G67 Cat. # P21 Junction Boxes and Bracket Bodies VXF – 4 Hubs, 3 Plugs Hub Size 1⁄2 3⁄4 Cat. # VXF10 VXF20 VXFT– 5 Hubs, 4 Plugs Hub Size 1⁄2 3⁄4 Cat. # VXFT10 VXFT20 * For non-hazardous locations. – available with Lightning Service TMdelivery See Section G for complete details 812 STIBOINFO((CRH:66008com:6L:812)) CH0 0 5 L - 2 VXT – 3 Hubs, 2 Plugs Hub Size 1⁄2 3⁄4 Cat. # VXT10 VXT20 VXA – Stanchion Mount (Non Hazardous Locations) Hub Size 11⁄4 Cat. # VXA4 VXB – 3 Hubs, 2 Plugs Hub Size 1⁄2 3⁄4 Cat. # VXB10 (Includes adapter plate and two gaskets for mounting to VXF, GRF or 4⍯ outlet boxes) VXB11 (Includes 1 gasket for mounting to VXF or GRF junction boxes.) ** All mountings except stanchion. US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-0813-2 Name: 6L-813 100: DATE: JAN 19 2006 Time: 5:53:02 PM Operator: TB COLOR: CMYK TCP: 15001 Family Tree Vaporgard TM Series Fluorescent Luminaires Typedriver Name: TS name csm no.: 100 6L – available with Lightning Service TM delivery. See Section G for complete details. US: 1-866-764-5454 STIBOINFO((CRH:66008com:6L:813)) CH0 0 5 L - 1 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds 813 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-0814-5 Name: 6L-814 6L 100: DATE: JAN 19 2006 Time: 5:53:03 PM Operator: TB CPMVF Champ-Pak TM Compact Fluorescent Luminaires COLOR: CMYK ɀ Cl. I, Div. 2, Groups A, B, C, D Restricted Breathing Cl. I, Div. 2 & Zone 2* (Suffix S826) ɀ Certified for IEC Zone 2* (Suffix S826TB) ɀ TCP: 15001 Typedriver Name: TS name csm no.: 100 ɀ Cl. II Groups E, F, G, Cl. III & Simultaneous Presence* ɀ Marine & Wet Locations ɀ 3, 3R, 4, 4X; IP56 Application: CPMVF Champ-Pak TM luminaires are used: ɀ Indoor and outdoor wall mounting or vertical surface mounting where minimal luminaire depth is required in: – Manufacturing plants and heavy industrial facilities – Industrial process facilities such as refineries, chemical, petrochemical, pharmaceutical and platforms – Waste or sewage treatments plants – Offshore, dockside and harbor installations ɀ For security and safety lighting in industrial facilities for lighting of loading docks, tunnels and stairways ɀ For marine, wet location, hosedown and corrosive environments Features & Benefits: ɀ Unique compact shallow-profile design mounts virtually anywhere ɀ Side hinged cover with two screw closing for easy installation and maintenance ɀ Gray Corro-free TM epoxy powder coat two-piece housing provides superior corrosion resistance ɀ Unique stainless steel wire guard accessory attaches without any additional hardware for easy installation and maintenance ɀ Glass refractor provides uniform light distribution to eliminate glare ɀ Silicon gaskets make luminaire suitable for NEMA 4X, Marine environments ɀ High power factor ballasts (+90%) are standard, which allow more luminaires per circuit Standard Materials: ɀ Luminaire housing and door frame assembly – copper-free aluminum ɀ External hardware – stainless steel ɀ Lens – heat and impact-resistant refractor style glass ɀ Gaskets – silicon rubber ɀ Reflector – aluminum light sheet ɀ Wire guard – stainless steel Standard Finishes: ɀ Aluminum – Corro-free TM epoxy powder coat ɀ Stainless steel – natural Certificates and Compliances: ɀ NEC and CEC: - Class I, Division 2, Groups A, B, C, D - Class II, Class III & Simultaneous Presence (Class 1, Division 2 and Class II)* - Class I Zone 2 ɀ IEC: - Zone 2 Ex nR IIC ɀ UL Standards: - 844, 2279 Hazardous (Classified) Locations - 1598 Luminaires - 1598A Marine Locations ɀ CSA Standards - C22.2 No. 137 ɀ IEC Standards - 60079-15 Electrical Rating Ranges: ɀ Wattages: Two 26, 32, or 42 watt lamps. ɀ 120-277V, 50-60Hz ɀ 347V, 60Hz ɀ 12, 24 & 125VDC (Consult Cooper Crouse-Hinds) Options: Suffix to add to Cat. No. # ɀ Restricted Breathing Construction - Class I Division 2 & Zone 2 Suitability . . . . . . . . . . . . . . . . . . . S826* - Cooler Operating Temperatures (T-Numbers) ɀ Certified for IEC Zone 2 (Suffix S826TB). . . . . . . . . . . . . . . . . S826TB* (Guard Required) - Furnished with - Terminal Block - Crimp Terminals ɀ Factory Assembled with Lamp . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . FA ɀ Fused - protects ballast and capacitors. . . . . . . . . . . . . . . . . . . . S658† against abnormal line conditions (Not for use in Canada) (Not for Marine use) Accessories: Photocell for Field Installation ɀ 120V, 50/60Hz ɀ 208-240V, 50/60Hz ɀ 277V, 50/60Hz Stainless Steel Wire Guard ɀ Less wattage used with compact fluorescent lamps compared to equivalent incandescent lamps providing the same light output. * Contact Cooper Crouse-Hinds STIBOINFO((CRH:66008com:6L:814)) CH0 5 L - 1 4 US: 1-866-764-5454 V2PC20 V2PC22 V2PC27 P55 † When ordering Fuses for luminaires, option S658, you must specify the operating voltage. S658 can not be ordered with /MT in the catalog number. Energy Savings: 814 Cat. # CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: 100: JOB: CRMAIN06-0815-3 Name: 6L-815 DATE: JAN 19 2006 Time: 5:53:04 PM Operator: JB COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 Ordering Information Temperature Performance Data Dimensions & Weights CPMVF Champ-Pak TM Compact Fluorescent Luminaires 6L Ordering Information: Hub Size 3⁄4 NPT 3⁄4 NPT 3⁄4 NPT Luminaire Watts 52 64 84 Catalog Number CPMVF2W052 CPMVF2W064 CPMVF2W084 STANDARD VOLTAGE BALLASTS OPTIONAL BALLASTS NEC/UL & CEC/CSA (cUL) CEC/CSA (cUL) 120-277V 50-60Hz /UNV 347V 60Hz /347 Voltage Suffix (Consult Cooper Crouse-Hinds) 125V DC /125VDC 12V DC /012VDC 24V DC /024VDC CPMVF Temperature Performance Data – Consult Cooper Crouse-Hinds Dimensions (Inches) Net Weight: CPMVF Less Guard P55 Guard 17 Lbs 0.5 Lbs US: 1-866-764-5454 STIBOINFO((CRH:66008com:6L:815)) CH0 0 3 L - 4 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds 815 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-0816-5 Name: 6L-816 6L 100: DATE: JAN 19 2006 Time: 5:53:05 PM Operator: JB DMVF Series Compact Fluorescent Champ® Luminaires COLOR: CMYK ɀ Cl. I, Div 2, Groups A, B, C, D Restricted Breathing Cl. I, Div 2 & Zone 2 (Suffix S826) ɀ Certified for IEC Zone 2 (Suffix S826TB) ɀ Application: Energy Savings DMVF series Champ luminaires are used: ɀ in areas made hazardous by abnormal conditions resulting in the presence of flammable vapors or gases. ɀ in areas made hazardous by the presence of combustible dusts. ɀ where combustible dusts and flammable vapors are present simultaneously. ɀ in marine applications where water spray and corrosive atmospheres are considerations. ɀ on installations where vibration and rough usage are problems. ɀ where a cool, efficient light source is required. ɀ in areas that require lamps to reach full illumination immediately. ɀ in refineries, chemical and petrochemical facilities, grain processing, handling or storage facilities, manufacturing plants waste water treatment plants sewage treatment plants, oil terminals, food processing facilities, breweries, and any other manufacturing or processing facility where safe, reliable, hazardous area fluorescent or auxiliary lighting is needed. ɀ Less wattage used with compact fluorescent lamps compared to equivalent incandescent lamps providing the same light output. Standard Features: ɀ Housings made of die-cast copper-free aluminum (less than 0.4 of 1% copper) for strength and resistance to corrosion. ɀ Mounting modules equipped with integral hub set screws for vibration resistance (ceiling, pendant, and quad mounts). ɀ Hubs are provided with an integral conduit stop and bushing to help prevent damage to field wiring during installation. ɀ Epoxy powder finish and stainless steel external hardware for resistance to corrosion. ɀ Long-life gaskets which provide seals between mounting module, housing, and optical assembly. ɀ Grounding wire for safety. ɀ Cool operating design. ɀ Optional stainless steel open bottom guard permits direct access to the globe for easy relamping. ɀ Optional battery pack ballast for auxiliary lighting. TCP: 15001 Typedriver Name: TS name csm no.: 100 ɀ Cl. II Groups E, F, G, Cl. III & Simultaneous Presence ɀ Marine & Wet Locations ɀ 3, 3R, 4, 4X; IP66 Standard Materials: ɀ Ballast housings and mountings – copperfree aluminum (less than 0.4 of 1%). ɀ Exterior hardware and guards – stainless steel. ɀ Reflectors – Krydon® fiberglass-reinforced polyester material. ɀ Globe – heat and impact resistant internally fluted glass. Standard Finishes: ɀ Aluminum – gray epoxy powder coat. ɀ Krydon material – high reflectance white. ɀ Stainless steel – natural. Electrical Rating Ranges: ɀ Wattage: Two 26 or 32 watt lamps ɀ 120-277V, 50-60 Hz ɀ 347V, 60Hz ɀ 12, 24, & 125VDC Certificates and Compliances: ɀ NEC and CEC: Class I, Division 2, Groups A, B, C, D Class II, Class III & Simultaneous Presence (Class 1, Division 2 and Class II) Class I Zone 2 ɀ IEC: Zone 2 Ex nR IIC ɀ UL Standards: 844, 2279 Hazardous (Classified) Locations 1598 Luminaires 1598A Marine Locations ɀ CSA Standards C22.2 No. 137 ɀ IEC Standards 60079-15 Accessories: (Order separately) ɀ Reflectors (to be used with globe) Dome Cat. # RD739 30° Angle Cat. # RA739 Options: Description Suffix to add to Cat. No. # ɀ Restricted Breathing Construction Class I Division 2 & Zone 2 Suitability . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . S826 Cooler Operating Temperatures (T-Numbers) ɀ Certified for IEC Zone 2 (Suffix S826TB) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . S826TB Furnished with Terminal Block Crimp Terminals ɀ Factory Assembled with lamps installed for additional labor savings. . . . . . . . . . . . . . . . . . . . FA. ɀ Fused – to protect ballast against abnormal line conditions (not available on CSA certified fixtures) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . S658*. ɀ Lamps supplied with fixture . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . S714. ɀ Top hat with stainless steel threaded insert to attach ballast housing . . . . . . . . . . . . . . . . . S806. ɀ TEFLON® coating on globe for increased shatter protection . . . . . . . . . . . . . . . . . . . . . . . . . S808. * When ordering Fuses for luminaires, option S658, you must specify the operating voltage. S658 can not be ordered with /MT in the catalog number. 816 STIBOINFO((CRH:66008com:6L:816)) CH0 0 5 L - 8 US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: 100: JOB: CRMAIN06-0817-4 Name: 6L-817 DATE: JAN 19 2006 DMVF Series Compact Fluorescent Champ® Luminaires Time: 5:54:07 PM Operator: GK COLOR: CMYK ɀ Cl. I, Div 2, Groups A, B, C, D Restricted Breathing Cl. I, Div 2 & Zone 2 (Suffix S826) ɀ Certified for IEC Zone 2 (Suffix S826TB) ɀ Mounting Style Pendant Mount Hub Size 3⁄4 1 3⁄4 1 Luminaire Watts 52 64 Typedriver Name: TS name csm no.: 100 ɀ Cl. II Groups E, F, G, Cl. III & Simultaneous Presence ɀ Marine & Wet Locations ɀ 3, 3R, 4, 4X; IP66 6L DMVF Series Fluorescent Cat. No. with G303 Globe and P33 Guard DMVF2A052GP DMVF3A052GP DMVF2A064GP DMVF3A064GP Flexible Pendant Mount 3⁄4 3⁄4 52 64 DMVF2HA052GP DMVF2HA064GP Ceiling Mount Thru-Feed 3⁄4 52 1 3⁄4 1 64 DMVF2C052GP DMVF3C052GP DMVF2C064GP DMVF3C064GP 3⁄4 52 1 3⁄4 1 64 Wall Mount Thru-Feed TCP: 15001 DMVF2TW052GP DMVF3TW052GP DMVF2TW064GP DMVF3TW064GP Quad-Mount Pendant, Adjustable Thru-Feed, 25° Angle, 121⁄2° Angle 3⁄4 3⁄4 52 64 DMVF25Q052GP DMVF25Q064GP Stanchion Mount 25° Angle 11⁄2 11⁄2 52 64 DMVFJ052GP DMVFJ064GP Stanchion Mount Straight 11⁄2 11⁄2 52 64 DMVFP052GP DMVFP064GP 1. Catalog numbers are basic numbers. Voltages must be specified. Voltage Suffix STANDARD VOLTAGE BALLASTS NEC/UL & CEC/CSA (cUL) 120-277V 50-60Hz /UNV US: 1-866-764-5454 STIBOINFO((CRH:66008com:6L:817)) CH0 0 5 L - 9 CAN: 1-800-265-0502 OPTIONAL BALLASTS CEC/CSA (cUL) 347V 60Hz /347 125V DC /125VDC Copyright© 2006 Cooper Crouse-Hinds 12V DC /012VDC 24V DC /024VDC 817 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-0818-2 Name: 6L-818 6L 100: DATE: JAN 19 2006 Time: 5:54:12 PM Operator: TB COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 DMVF Series Ordering by Components DMVF luminaires are available in components A complete luminaire consists of: I. Champ Cover (Mounting Module) II. DMVF Ballast Housing III. Globe, Globe Guard, Globe Reflectors I. Champ Cover (Mounting Module): Type Pendant Flexible Pendant Ceiling Wall Stanchion - 25 Degree Angle Stanchion - Straight Quad-Mount Conduit 3⁄4 1 3⁄4 3⁄4 1 3⁄4 1 11⁄2 11⁄2 3⁄4 Cat. No. APM2 APM3 HPM2 CM2 CM3 TWM2 TWM3 JM5 PM5 QM25 II. Ballast Housings. Complete catalog number must have the voltage suffix (UNV shown) and any options suffixes. Lamp Type Compact Fluorescent Lamp Watts 2 (26W) 2 (32W) Catalog Number DMVF052/UNV DMVF064/UNV III. Globe, Guards and Reflectors Type Globe Teflon Coated Globe Guard Globe Reflector-Dome Globe Reflector-Angle 818 STIBOINFO((CRH:66008com:6L:818)) CH0 3 L - 1 5 Catalog Number G303 G303-S808 P33 RD739 RA739 US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-0819-2 Name: 6L-819 100: DATE: JAN 19 2006 Time: 5:54:13 PM Operator: TB COLOR: CMYK TCP: 15001 Family Tree DMVF Series Compact Fluorescent Typedriver Name: TS name csm no.: 100 6L Champ® Luminaires * These plastic reflectors are for non-hazardous areas only (50-100W max.) – available with Lightning Service TM delivery. See Section G for complete details. US: 1-866-764-5454 STIBOINFO((CRH:66008com:6L:819)) CH0 3 L - 1 5 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds 819 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: 100: JOB: CRMAIN06-0820-2 Name: 6L-820 6L DATE: JAN 19 2006 Time: 5:54:14 PM Operator: TB COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 Temperature Performance Data Weights DMVF Series Compact Fluorescent Champ® Luminaires Temperature Performance Data: Lamp Watts Fluorescent: Minimum Operating Temperature DMVF 52 & 64 Watt -20°C (4°F) Class I Non-Restricted Restricted Breathing Breathing Div. 2 Zone 2 or Div. 2 40°C (104°F) T3 T6 Maximum Ambient Temp Class II Division 1 T6 Simultaneous Presence Non-Restricted Restricted Breathing Breathing Cl.I, Div. 2/Cl.II Cl.I, Zone 2 or Div. 2/Cl.II T3/T6 T6 Net Luminaire Weights (lbs.) Luminaire Luminaire Lamp with Globe, Series Watts Guard (lbs.) DMVF 52, 64 181⁄4 Add for mounting modules (lbs.): Pendant 11⁄4 Flexible Pendant 11⁄2 Ceiling 23⁄4 Wall 41⁄2 Quad-Mount 31⁄2 Angle Stanchion 31⁄2 Straight Stanchion 41⁄2 Add for reflectors (lbs.): Dome 11⁄4 30° Angle 13⁄4 Deduct: 1 lb. for luminaire with P33 Guard 820 STIBOINFO((CRH:66008com:6L:820)) CH0 5 L - 1 0 US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds Supply Wire °C 60 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: 100: JOB: CRMAIN06-0821-2 Name: 6L-821 DATE: JAN 19 2006 Time: 5:54:15 PM Operator: TB COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 Photometric Data DMVF Series Compact Fluorescent 6L Champ® Luminaires NOTE: For 52 watt DMVF applications, use a .75 multiplier. DMVF064GRD Dome Reflector Coefficients of Utilization Effective Floor Cavity Reflectance 20% DMVF Photometric Data ISOFOOTCANDLE CHART: Luminaire with globe and dome reflector DMVF064GRD Dome Reflector Room Cavity Ratio Eff. Ceil. 80* 70* 50* Wall 1 2 3 4 5 6 7 8 9 10 50* 30* 10* 50* 30* 10* .741 .694 .652 .722 .679 .640 .617 .548 .491 .601 .537 .483 .524 .445 .382 .510 .437 .378 .452 .370 .308 .440 .364 .305 .396 .314 .254 .386 .309 .252 .351 .271 .214 .342 .267 .212 .314 .237 .183 .307 .234 .182 .283 .210 .159 .277 .207 .158 .258 .188 .140 .252 .185 .139 .236 .169 .125 .231 .167 .124 50* 30* 10* .686 .650 .617 .570 .516 .470 .484 .421 .369 .418 .351 .299 .367 .299 .247 .326 .259 .209 .293 .227 .180 .265 .202 .155 .242 .181 .138 .223 .163 .123 .542 .497 .457 .516 .478 .444 .424 .460 .406 .361 .437 .392 .352 .332 .398 .340 .293 .379 .329 .287 .267 .350 .290 .243 .333 .271 .239 .220 .311 .251 .206 .297 .244 .203 .184 .280 .221 .177 .268 .215 .175 .157 .254 .197 .154 .244 .192 .152 .136 .233 .176 .136 .224 .172 .135 .119 .214 .160 .121 .206 .156 .120 .105 50* .653 30* .623 10* .596 .50* .622 10* 30* .598 10* .576 0* 0* .557 * Percent Reflectance 30* Footcandle Values for Isofootcandle Lines MTG. HGT. 8′ 10′ 12′ 16′ A 4.00 2.56 1.78 1.00 B 2.00 1.28 0.89 0.50 C 1.00 0.64 0.44 0.25 D 0.50 0.32 0.22 0.13 E 0.25 0.16 0.11 0.06 US: 1-866-764-5454 STIBOINFO((CRH:66008com:6L:821)) CH0 5 L - 1 2 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds 821 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: 100: JOB: CRMAIN06-0822-2 Name: 6L-822 DATE: JAN 19 2006 Time: 5:54:16 PM Operator: TB TCP: 15001 Dimensions DMVF Series Compact Fluorescent 6L COLOR: CMYK Champ® Luminaires DMVF Dimensions Pendant Mount Quad-Mount 25° Angle Stanchion Mount Ceiling Mount Ceiling Mount – Top View Straight Stanchion Mount 822 STIBOINFO((CRH:66008com:6L:822)) CH0 5 L - 1 3 Luminaire with Globe, Guard, Reflectors US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds Typedriver Name: TS name csm no.: 100 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-0823-2 Name: 6L-823 100: DATE: JAN 19 2006 N2MVF Series Compact Fluorescent Champ® Non-metallic Luminaires Time: 5:54:19 PM Operator: TB ɀ Cl. I, Div. 2, Groups A,B,C,D Restricted Breathing Cl. I, Div. 2 & Zone 2 (Suffix S826) ɀ Certified for IEC Zone 2 (Suffix S826TB) ɀ Additional Features: FLUORESCENT ENERGY SAVINGS ɀ Less wattage used with compact fluorescent lamps compared to equivalent incandescent lamps providing the same light output. 6L Certifications and Compliances: ɀ NEC and CEC: Class I, Division 2, Groups A,B,C,D Class II, Class III & Simultaneous Presence (Class I Division 2 and II) Class I Zone 2 ɀ IEC: Zone 2 Ex nR IIC ɀ UL Standards: 844. 2279 Hazardous (Classified) Locations 1598 Luminaires 1598A Marine Locations ɀ CSA Standards: C22.2 No. 137 ɀ IEC Standards: 60079-15 Standard Materials: ɀ Housing, mounting modules – polyphenylene sulfide (PPS) ɀ Guard, hub inserts, stanchion elbow, hardware – stainless steel ɀ Globe – heat & impact resistant, internally fluted glass ɀ Gaskets – silicone rubber Electrical Ratings: ɀ Wattages: Two 26 or 32 watt lamps. ɀ 120 – 277V, 50-60 Hz ɀ 347V, 60 Hz ɀ 12, 24 & 125 VDC US: 1-866-764-5454 STIBOINFO((CRH:66008com:6L:823)) Typedriver Name: TS name csm no.: 100 Cl. II Groups F,G, Cl. III & Simultaneous Presence ɀ Marine & Wet Locations ɀ 3,3R, 4,4X; IP56 N2MVF series Champ luminaires are used: ɀ in areas in which ignitable concentrations of flammable gases or vapors will be present due to abnormal, unusual or accidental conditions. ɀ in installations where moisture, dirt, vibration, corrosion or rough usage are concerns. ɀ wherever the damaging effects of water, wind, snow, sleet, hot sun or any combination of these elements are found. ɀ ideal for marine use; resists the harmful effects of salt water. ɀ withstands the harshest of corrosive environments. ɀ to provide low wattage spot and floodlighting. ɀ for general area lighting. ɀ in manufacturing plants, refineries, chemical, petrochemical and other industrial process facilities, wastewater and sewage treatment facilities, offshore, dockside and harbor installations as well as other heavy industrial applications. ɀ Housings and mounting modules made of polyphenylene sulfide (PPS) for strength and maximum resistance to corrosion. ɀ Pendant mounting module equipped with integral hub set screws for vibration resistance. ɀ Hubs are provided with an integral bushing to help prevent damage to field wiring during installation and ground connection for positive bonding. ɀ Guard, hub inserts, stanchion elbow and hardware made of stainless steel for maximum resistance to corrosion. ɀ Grounding wire for safety. ɀ Stainless steel open bottom guard permits direct access to the globe for easy relamping. ɀ Hinged assembly allows the luminaire to hang free during installation to permit the use of both hands when wiring. ɀ One, external captive screw for ease of installation. ɀ Handle – hinge assembly doubles as a handle for ease of installation, especially when carrying up a ladder. TCP: 15001 ɀ Application: Features and Benefits: CH0 5 L - 1 4 COLOR: CMYK Options: Description Suffix to be added to Cat. No. ɀ Restricted Breathing Construction S826 Class I Division 2 & Zone 2 Suitability Cooler Operating Temperatures (T-Numbers) ɀ Certified for IEC Zone 2 S826TB Furnished with Terminal Block Crimp Terminals Wall-Mount Arm For converting a ceiling-mount luminaire to a wall mount N2MV-WM1 Factory Assembled For a factory assembled luminaire with lamps installed FA Fusing To protect ballast against abnormal line conditions S658 Furnished with Lamps S714 Teflon Coated Globe Provides additional protection against shattered glass fragments when subject to thermal shock, etc. S808 Average Luminaire Weight (lbs.) Body, mounting module, globe, guard and reflector . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 lbs. CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds 823 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-0824-2 Name: 6L-824 100: DATE: JAN 19 2006 Time: 5:54:19 PM Operator: TB N2MVF Series Compact Fluorescent 6L Champ® Non-metallic Luminaires COLOR: CMYK ɀ Cl. I, Div. 2, Groups A,B,C,D Restricted Breathing Cl. I, Div. 2 & Zone 2 (Suffix S826) ɀ Certified for IEC Zone 2 (Suffix S826TB) ɀ TCP: 15001 Typedriver Name: TS name csm no.: 100 ɀ Cl. II Groups F,G, Cl. III & Simultaneous Presence ɀ Marine & Wet Locations ɀ 3,3R, 4,4X; IP56 N2MVF ORDERING INFORMATION Mounting Style Pendant Mount Ceiling Mount ThruFeed Stanchion Mount 25° Angle Hub Size 3⁄4 1 3⁄4 1 3⁄4 1 3⁄4 1 11⁄2 11⁄2 Lamp Watts 52 64 52 64 52 64 With G303 Globe and P33 Guard Cat. No.† N2MVF2A052GP N2MVF3A052GP N2MVF2A064GP N2MVF3A064GP N2MVF2C052GP N2MVF3C052GP N2MVF2C064GP N2MVF3C064GP N2MVFJ052GP N2MVFJ064GP STANDARD VOLTAGE BALLASTS Voltage Suffix NEC/UL & CEC/CSA (cUL) 120-277V 50-60Hz /UNV OPTIONAL BALLASTS CEC/CSA (cUL) 347V 60Hz /347 125V DC /125VDC 12V DC /012VDC 24V DC /024VDC Temperature Performance Data: Lamp Watts Fluorescent: 52 & 64 Watt 824 STIBOINFO((CRH:66008com:6L:824)) CH0 5 L - 1 5 Class I Minimum Maximum Operating Ambient Non-Restricted Restricted Temperature Temp Breathing Breathing N2MVF Division 2 Zone 2 -18°C (0°F) 40°C (104°F) T2D T6 US: 1-866-764-5454 CAN: 1-800-265-0502 Class II Division 1 T4 F & G Simultaneous Presence Non-Restricted Restricted Breathing Breathing Cl.I, Div 2/Cl.II Cl.I, Zone 2/Cl.II T2B/T4 T4 Copyright© 2006 Cooper Crouse-Hinds Supply Wire °C 85 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-0825-3 Name: 6L-825 100: DATE: JAN 19 2006 Time: 5:54:20 PM Operator: RB COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 N2MVF SeriesOrdering by Components 6L N2MVF luminaires are available in components A complete luminaire consists of: I. N2MV Cover (Mounting Module) II. N2MV Ballast Housing III. Globe, Refractors, Guards, Reflectors I. N2MV Cover (Mounting Module): Type Pendant Ceiling Wall (Use wall bracket accessory with Ceiling Cover) Stanchion - 25 Degree Angle Conduit 3⁄4 1 3⁄4 1 3⁄4 1 11⁄2 Cat. No. N2APM2 N2APM3 N2CM2 N2CM3 N2MV-WM1 and N2CM2 N2MV-WM1 and N2CM3 N2JM5 II. Ballast Housings. Complete catalog number must have the voltage suffix (UNV shown) and any options suffixes. Lamp Type Compact Fluorescent Lamp Watts 2 (26W) 2 (32W) Catalog Number N2MVF052/UNV N2MVF064/UNV III. Globe, Guard and Reflectors Type Globe Globe Teflon Coated Globe Guard Reflector Dome Reflector Angle Catalog Number G303 G303-S808 P33 RD739 RA740 US: 1-866-764-5454 STIBOINFO((CRH:66008com:6L:825)) CH0 3 L - 1 5 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds 825 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-0826-2 Name: 6L-826 6L 100: DATE: JAN 19 2006 Time: 5:54:21 PM Operator: TB N2MVF Series Compact Fluorescent COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 Family Tree Champ® Non-metallic Luminaires A complete luminaire consists of a cover mount, a ballast housing and a globe, with or without guard, refractor or reflector. ALL COMPONENTS ARE SUITABLE FOR USE IN ORDINARY LOCATIONS, CLASS 1, DIV.2 AND WET LOCATIONS. 826 STIBOINFO((CRH:66008com:6L:826)) CH0 3 L - 3 0 US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: 100: JOB: CRMAIN06-0827-3 Name: 6L-827 DATE: JAN 19 2006 Time: 5:54:22 PM Operator: TB N2MVF Series Compact Fluorescent COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 6L Dimensions Weights Champ® Non-Metallic Luminaires Pendant Mount Ceiling Mount – Top View Ceiling Mount 25° Angle Stanchion Mount Wall Arm Mount Net Luminaire Weights (lbs.) Luminaire Series Lamp Watts Luminaire with Mounting Module, Globe, Guard & Refractor (lbs.) N2MVF052 N2MVF064 52 64 30 30 Accessories (Order Separately) Reflectors (to be used with globe) Dome Cat. RD739 (RD79) 30° Angle Cat. RA739 (RA79) US: 1-866-764-5454 STIBOINFO((CRH:66008com:6L:827)) CH0 5 L - 1 8 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds 827 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-0828-3 Name: 6L-828 6L 100: DATE: JAN 19 2006 Time: 5:54:23 PM Operator: TB COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 N2MVF Series Compact Fluorescent Champ® Non-Metallic Luminaires Photometric Data NOTE: For 52 watt N2MVF applications, use a .75 multiplier. N2MVF Photometric Data ISOFOOTCANDLE CHART: Luminaire with globe and dome reflector N2MVF064GRD Dome Reflector Footcandle Values for Isofootcandle Lines MTG. HGT. A B C D E 8′ 4.00 2.00 1.00 0.50 0.25 10′ 2.56 1.28 0.64 0.32 0.16 12′ 1.78 0.89 0.44 0.22 0.11 16′ 1.00 0.50 0.25 0.13 0.06 828 STIBOINFO((CRH:66008com:6L:828)) CH0 5 L - 1 6 US: 1-866-764-5454 N2MVF064GRD Dome Reflector Coefficients of Utilization Effective Floor Cavity Reflectance 20% Room Cavity Ratio Eff. Ceil. Wall 1 2 3 4 5 6 7 8 9 10 80* 50* 30* 10* .741 .694 .652 .617 .548 .491 .524 .445 .382 .452 .370 .308 .396 .314 .254 .351 .271 .214 .314 .237 .183 .283 .210 .159 .258 .188 .140 .236 .169 .125 70* 50* 30* 10* .722 .679 .640 .601 .537 .483 .510 .437 .378 .440 .364 .305 .386 .309 .252 .342 .267 .212 .307 .234 .182 .277 .207 .158 .252 .185 .139 .231 .167 .124 .570 .516 .470 .542 .497 .457 .516 .478 .444 .424 .484 .421 .369 .460 .406 .361 .437 .392 .352 .332 .418 .351 .299 .398 .340 .293 .379 .329 .287 .267 .367 .299 .247 .350 .290 .243 .333 .271 .239 .220 .326 .259 .209 .311 .251 .206 .297 .244 .203 .184 .293 .227 .180 .280 .221 .177 .268 .215 .175 .157 .265 .202 .155 .254 .197 .154 .244 .192 .152 .136 .242 .181 .138 .233 .176 .136 .224 .172 .135 .119 .223 .163 .123 .214 .160 .121 .206 .156 .120 .105 50* .686 30* .650 10* .617 50* .653 30* 30* .623 10* .596 50* .622 10* 30* .598 10* .576 0* 0* .557 * Percent Reflectance 50* CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-0829-4 Name: 6L-829 100: DATE: JAN 19 2006 EVLPF Series Compact Fluorescent Low Profile Hazard ȿ Gard® Luminaires Time: 5:54:23 PM Operator: JB COLOR: CMYK ɀ Cl. I, Div. 1, Groups B (GB Suffix),C,D Cl. I, Zone 1, Groups IIB + H2 (GB Suffix), IIB, IIA ɀ Cl. II, Div 1, Groups E, F, G; Class III, Simultaneous Presence ɀ TCP: 15001 Typedriver Name: TS name csm no.: 100 ɀ Marine & Wet Locations ɀ 3,3R,4,4X; IP66 6L Application: Cooper Crouse-Hinds Low Profile Hazard ȿ Gard® luminaires are used in: ɀ areas where flammable or explosive vapors or gases are present ɀ hazardous areas, both indoors and outdoors, where long life and low maintenance costs are desired ɀ petroleum refineries, chemical, petrochemical and pharmaceutical plants, oil terminals, gas plants and other heavy process industry facilities ɀ waste treatment facilities ɀ drilling platforms and other coastal and offshore hazardous areas Features - Benefits: ɀ Small compact size ɀ Two start Acme threaded construction ɀ Light weight copper-free aluminum housing with powdered epoxy finish ɀ All exterior hardware is corrosion-resistant stainless steel ɀ Four mounting arrangements pendant, ceiling, wall bracket and stanchion ɀ Wide range of light sources and wattages ɀ Marine and Nema 4X construction ɀ Integral ballast ɀ High power factor (90%+) ballasts ɀ Uses same mounting modules as the standard Hazard ȿ Gard® ɀ Internally fluted glass globes ɀ Krydon® construction dome and angle reflectors – won’t rust, corrode, dent, chip or peel ɀ Now available in components – luminaire body, mounting module, guard, reflectors ɀ Three wire construction is standard on Fluorescent Emergency Lighting ɀ Perfect where low mounting restrictions are a concern ɀ Easier assembly, installation and maintenance ɀ Superior corrosion resistance ɀ Suit any lighting layout ɀ Meet specific lighting needs ɀ Outdoor, hose down, marine and corrosive environments suitable ɀ Lowest installed cost ɀ Allows more luminaires per circuit ɀ Easy retrofitting when the Lo-Pro TM is the preferred choice ɀ Reduces glare and distributes light evenly – ideal for adverse environments typical of industrial facilities ɀ Ideal for adverse environments typical of industrial facilities ɀ Easily stocked for quick ship requirements ɀ For energy conservation, luminaires can be switched off without affecting the emergency operation feature Standard Finishes: Copper-free aluminum – Corro-free powdered epoxy ɀ Krydon – white ɀ Stainless steel guard TM Ratings (Electrical/Size): Sources/wattage: ɀ 52W (2-26W lamps) & 64W (2-32W lamps) ɀ 120-277V, 50-60 Hz ɀ 347V, 60Hz ɀ 12, 24, 125 VDC Conduit entries: ɀ 3⁄4⍯, 1⍯ NPT – Pendant, Wall Bracket, Ceiling ɀ 11⁄4⍯ NPT – Stanchion Certification & Compliances: ɀ NEC and CEC: Class I, Division 1, Groups B (GB suffix), C, D Class I, Zone 1 Groups IIB + H2 (GB Suffix),IIB, IIA Class II, Class III & Simultaneous Presence (Class I and Class II) ɀ UL Standards 844 Hazardous (Classified) Locations 1598 Luminaires 1598A Marine Locations ɀ CSA Standards C22.2 No. 137 Options: Description Group B suitability Fused Factory assembled with lamps Suffix to be added to Cat. # GB S658* FA Accessories: Description Dome reflector Angle reflector Cat. # RD739 RA739 * When ordering Fuses for luminaires, option S658, you must specify the operating voltage. S658 can not be ordered with /MT in the catalog number. Standard Materials: ɀ Mounting modules, cover, ballast housing, globe holder – copper free aluminum ɀ Globe – heat and impact resistant glass ɀ Exterior hardware – stainless steel ɀ Reflectors (dome & angle) – Krydon TM fiberglass-reinforced polyester US: 1-866-764-5454 STIBOINFO((CRH:66008com:6L:829)) CH0 0 6 L 1 7 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds 829 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-0830-2 Name: 6L-830 100: DATE: JAN 19 2006 Time: 5:54:25 PM Operator: TB EVLPF Series Compact Fluorescent 6L Low Profile Hazard ȿ Gard® Luminaires COLOR: CMYK TCP: 15001 ɀ ɀ ɀ ɀ Cl. I, Div. 1, Groups B (GB Suffix),C,D Cl. I, Zone 1, Groups IIB + H2 (GB Suffix), IIB, IIA ɀ Cl. II, Div 1, Groups E, F, G; Class III, Simualtaneous Presence Typedriver Name: TS name csm no.: 100 Marine & Wet Locations 3,3R, 4,4X; IP66 Ordering Information Pendant Hub With Guard Watt Size Catalog # Wall Brckt† With Guard Catalog # Ceiling† With Guard Catalog # Stanchion With Guard Catalog # Fluorescent—High Power Factor Ballast (Min. P.F. 90%) EVLPFA02521 EVLPFBX02521 EVLPFCX02521 52W 3⁄4 1 EVLPFA03521 EVLPFBX03521 EVLPFCX03521 EVLPFJ04521 11⁄4 64W 3⁄4 EVLPFA02641 EVLPFBX02641 EVLPFCX02641 1 EVLPFA03641 EVLPFBX03641 EVLPFCX03641 EVLPFJ04641 11⁄4 Pendant Mount Luminaire Body Less Mounting Module & Guard Catalog # EVLPF0520 EVLPF0640 Complete Catalog Number as follows: 1. Voltages - Add Suffix as follows: Standard Voltage Ballasts - 60Hz Voltage Suffix NEC/UL & CEC/CSA (cUL) 120-277V 50-60Hz /UNV Optional Ballasts CEC/CSA (cUL) 347V 60 Hz /347 125V DC /125VDC †Wall Bracket Mount †Ceiling Mount Stanchion Mount †Ceiling and bracket mounts have 4 hubs: 3 are plugged. 830 STIBOINFO((CRH:66008com:6L:830)) CH0 5 L - 1 9 US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds 12V DC /012VDC 24V DC /024VDC Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-0831-3 Name: 6L-831 100: DATE: JAN 19 2006 Time: 5:54:26 PM Operator: JB COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 EVLPF Series Ordering By Components 6L EVLP Luminaires are available in components. A complete light fixture consists of: I. Mounting Module II. Fixture Body III. Guard, Dome Reflector, Angle Reflector or Exit Sign Mounting Modules Type Pendant Conduit 3⁄4 1 3⁄4 1 Use EV22 or EV33 box with EV87 11⁄4 Ceiling & Wall Box Wall Bracket Arm Stanchion Guards Fluorescent Reflectors Dome Angle Catalog Number EVMP2 EVMP3 EV22 EV33 EV87 EVMJ4 EV512 RD739 RA739 PENDANT EVMP2 EVMP3 CEILING EV22 EV33 STANCHION EVMJ4 CEILING EV22 EV33 WALL BRACKET EV87 & EV22 or EV33 FIXTURE BODY EVLPF0520/UNV EVLPF0521/UNV EVLPF0640/UNV EVLPF0641/UNV GUARDS EV511 EV512 US: 1-866-764-5454 STIBOINFO((CRH:66008com:6L:831)) CH0 0 5 L - 4 DOME REFLECTOR RD739 CAN: 1-800-265-0502 ANGLE REFLECTOR RA739 Copyright© 2006 Cooper Crouse-Hinds 831 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: 100: JOB: CRMAIN06-0832-2 Name: 6L-832 6L DATE: JAN 19 2006 Time: 5:54:27 PM Operator: TB COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 Temperature Performance Data EVLPF Series Compact Fluorescent Low Profile Hazard ȿ Gard® Luminaires Fluorescent Fixtures Maximum Ambient Fluorescent 832 STIBOINFO((CRH:66008com:6L:832)) CH0 0 5 L - 4 52W & 64W Class I, Group B (w/GB suffix) Groups C, D Class I Zone I 40°C T6 US: 1-866-764-5454 Class II Groups E, F, G Class III Simultaneous Presence 40°C T6 CAN: 1-800-265-0502 Supply Wire °C 75°C Copyright© 2006 Cooper Crouse-Hinds Minimum Operating Temperature -18°C Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-0833-2 Name: 6L-833 100: DATE: JAN 19 2006 Time: 5:54:28 PM Operator: TB COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 Dimensions and Weights EVLPF Series Compact Fluorescent 6L Low Profile Hazard ȿ Gard® Luminaires Fluorescent A 15.69 B 14.69 C 18.25 D 18.46 E 22.34 F 21.30 WEIGHTS (LBS.) Item Fluorescent Weights 31.5 (EVLPF) Add Mounting Modules Pendant Ceiling Bracket Stanchion Add For Reflectors & Exit Sign RA739 RD739 DMVF–EXD Deduct for Wire Guard 1 2 4.5 2.5 1 1 5 .5 US: 1-866-764-5454 STIBOINFO((CRH:66008com:6L:833)) CH0 0 5 L - 4 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds 833 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-0834-2 Name: 6L-834 6L 100: DATE: JAN 19 2006 Time: 5:54:29 PM Operator: TB COLOR: CMYK TCP: 15001 Photometric Data EVLPF Series Compact Fluorescent Low Profile Hazard ȿ Gard® Luminaires Luminaire with Globe and Guard EVLPFA03641 (2) 32 W Compact Fluorescent CANDELAS Mid-Zone Angle Candelas 0 174 5 187 15 219 25 263 35 299 45 313 55 315 65 317 75 309 85 284 95 248 105 198 115 135 125 71 135 23 145 3 155 0 165 0 175 0 180 0 834 STIBOINFO((CRH:66008com:6L:834)) CH0 0 5 L - 4 US: 1-866-764-5454 CAN: 1-800-265-0502 ZONAL LUMENS Zone 0-10 10-20 20-30 30-40 40-50 50-60 60-70 70-80 80-90 90-100 100-110 110-120 120-130 130-140 140-150 150-160 160-170 170-180 Lumens 18 61 115 174 233 294 345 368 365 321 234 134 51 11 1 0 0 0 Copyright© 2006 Cooper Crouse-Hinds Typedriver Name: TS name csm no.: 100 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-0835-2 Name: 6L-835 100: DATE: JAN 19 2006 Time: 5:55:33 PM Operator: TB COLOR: CMYK TCP: 15001 Photometric Data EVLPF Series Compact Fluorescent Typedriver Name: TS name csm no.: 100 6L Low Profile Hazard ȿ Gard® Luminaires Luminaire with Globe and Dome (Less Guard) EVLPFA03640RD Lamp: (2) 32 W Compact Fluorescent CANDELAS Mid-Zone Angle Candelas 0 582 5 595 15 651 25 672 35 644 45 596 55 493 65 331 75 139 85 29 95 10 105 10 115 10 125 6 135 1 145 0 155 0 165 0 175 0 180 0 ZONAL LUMENS Zone 0-10 10-20 20-30 30-40 40-50 50-60 60-70 70-80 80-90 90-100 100-110 110-120 120-130 130-140 140-150 150-160 160-170 170-180 Lumens 57 176 291 384 450 461 347 145 31 11 10 6 1 0 0 0 0 0 Luminaire with Globe and 30° Angle Reflector (Less Guard) EVLPFA03640RA Lamp: (2) 32 W Compact Fluorescent CANDELAS Degrees 0 5 15 25 35 45 55 65 75 85 95 105 115 125 135 145 155 165 175 180 Front Side Back 524 524 524 565 526 487 637 528 452 751 541 425 816 550 315 798 551 157 749 453 18 684 258 1 605 93 1 450 20 9 260 10 9 99 10 9 18 9 9 0 1 9 0 0 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 ZONAL LUMENS Zone Lumens 0-10 51 10-20 152 20-30 255 30-40 337 40-50 371 50-60 353 60-70 301 70-80 230 80-90 144 90-100 71 100-110 15 110-120 7 120-130 2 130-140 0 140-150 0 150-160 0 160-170 0 170-180 0 US: 1-866-764-5454 STIBOINFO((CRH:66008com:6L:835)) CH0 0 5 L - 4 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds 835 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: 100: JOB: CRMAIN06-0836-3 Name: 6L-836 6L DATE: JAN 19 2006 Time: 5:55:38 PM Operator: TB COLOR: CMYK TCP: 15001 ɀ ɀ ɀ ɀ Cl. I, Div. 2, Groups B, C, D Cl. I, Zone 1, Groups IIC (Suffix S813) ɀ Cl. II, Div 1, Groups E, F, G (Suffix S813) ɀ Cl. II, Div 2, Groups F,G ɀ Cl. III, Simultaneous Presence FVS Series Long Twin Tube Fluorescent Luminaires Typedriver Name: TS name csm no.: 100 Marine & Wet Locations 3,3R, 4,4X; IP66 Application: FVS compact fluorescent luminaires are used: ɀ where low mounting heights or limited mounting room exists. ɀ for task oriented lighting. ɀ where a cool, efficient light source is required. ɀ in areas that require lamps to reach full illumination immediately. ɀ in industrial and chemical processing. ɀ in pulp and paper facilities. ɀ in waste or sewage treatment facilities. ɀ in non-hazardous commercial and industrial areas. ɀ in food and pharmaceutical plants where a non-glass lens is required. ɀ where fluorescent lighting has been preferred, but unavailable due to limited space and practicality. Features: ɀ Compact, lightweight, low profile design is ideal for confined areas and tight corners. ɀ Reaches full illumination immediately and delivers light output equivalent to fixtures twice its size. ɀ Fast-Latch TM closure provides quick and easy access for relamping and maintenance – no tools necessary. ɀ Silicone sealing gasket provides exceptional watertight and dust-tight bond, providing excellent performance in wet and corrosive environments. ɀ Power disconnect switch (Cooper CrouseHinds ESWP) automatically cuts power to the lamps and ballast when the lens is opened. ɀ Shatter-resistant polymeric lens (.125 thick) provides environmental and corrosion protection. ɀ Available in 120, 277, 220/240 and 347 50/60hz voltages. ɀ 2 lamp fixture, uses single-ended 40 watt lamps. ɀ Multiple mounting capability. ɀ Energy saving electronic ballast is standard. Standard Materials: ɀ Corrosion-resistant die cast copper-free aluminum housing. ɀ Shatter-resistant nylon lens. ɀ Polycarbonate lens (suffix-S813) ɀ Silicone rubber gasket. ɀ Extruded aluminum hinges and closure hardware with stainless steel pivots. Standard Finishes: ɀ Epoxy powder coated housing. ɀ Anodized hinges and closure hardware. ɀ Highly specular aluminum reflector. Size Ranges: ɀ All luminaires are 24⍯L x 12⍯W x 3.12⍯H. ɀ Conduit entrances are 3/4⍯. Certifications and Compliances: Accessories ɀ NEC and CEC: Class I, Division 2, Groups B,C,D Class I, Zone 1 Group IIC (suffix S813) Class II, Division 1, Groups E, F, G (Suffix S813) Class II Division 2 Groups F, G Class III & Simultaneous Presence (Cl. I and Cl. II) Note: Aiming Limitations Cl. II, Cl. III & Simultaneous Presence Aim down to Horizontal Cannot aim up ɀ UL Standards 844 Hazardous (Classified) Locations 1598 Luminaires 1598A Marine Locations ɀ CSA Standards C22.2 No. 137 FVS Trunnion Mount Kit (FVS-K5) ɀ Permits vertical mounting of luminaire on a beam when used with a standard beam clamp. ɀ Can be mounted directly to a wall or ceiling. ɀ Can be pole mounted when used in conjunction with a SFA6 slipfitter adapter (ordered separately). ɀ Constructed from copper-free aluminum. ɀ Supplied with a CGB cord connector. Options: Suffix to be added to Description Cat. No. ɀ Fused to protect ballast under abnormal line conditions. Not available on CSA certified fixtures.. . . . . . . . . . . . . . . . . . . . . . . S658* ɀ Fixture supplied with two F40BX/SPX35 lamps . . . . . . . . . . . . . . . . . . . . S714 ɀ Corro-free TM epoxy finish inside and out . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . S753 ɀ Class I, Zone 1, Group IIC and Class II, Div. 1, Groups E, F, G suitability. . . . . . . . . . . . . . . . . . . . . . . . . . . . . S813 ɀ Tamperproof . . . consult Cooper Crouse-Hinds FVS with Trunnion Arm and Slipfitter Temperature Performance Data: Style All All Ambient Temp °C 40°C 55°C Class I Div. 2 T3C T3C Zone I T3 — Class II See Aiming T6 — Simualtaneous Presence Limitations T3C/T6 — Luminaire Weight (lbs.) without lamps ɀ Standard 2 lamp FVS . . . . . . . . . . . . . . . . 12.0 Electrical Ratings: ɀ 120-277V, 50-60 Hz ɀ 347V, 60Hz ɀ Two 40 watt long twin tube lamps 836 STIBOINFO((CRH:66008com:6L:836)) CH0 5 L - 2 7 * When ordering Fuses for luminaires, option S658, you must specify the operating voltage. S658 can not be ordered with /MT in the catalog number. US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds Supply Wire 75°C 75°C Minimum Operating Temperature -18°C (0°F) -18°C (0°F) Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: 100: JOB: CRMAIN06-0837-3 Name: 6L-837 DATE: JAN 19 2006 FVS Series Long Twin Tube Fluorescent Luminaires Time: 5:55:40 PM Operator: JB COLOR: CMYK ɀ ɀ ɀ ɀ Cl. I, Div 2, Groups B,C,D Cl. I, Zone 1 Group IIC (suffix S813) ɀ Cl. II, Div 1,Groups E,F,G (suffix S813) ɀ Cl. II, Div 2, groups F,G ɀ Cl. III, Simultaneous Presence TCP: 15001 Typedriver Name: TS name csm no.: 100 Marine & Wet Locations 3,3R, 4,4X; IP66 6L Luminaire includes all necessary provisions for these installations: Ceiling Mount Pendant Mount Corner Mount FVS compact fluorescent (2 lamp luminaire): Voltage Wattage/ Lamp Hub Size (4) Cat. Number Cat. # with Class I, Zone 1 and Class II, Div. 1 Suitability 120 (50 or 60 Hz) 277 (50 or 60 Hz) 120–277 (50 or 60 Hz) 347 (50 or 60 Hz) 40 40 40 40 3⁄4⍯ FVS20 FVS27 FVS20UNV FVS23 FVS20–S813 FVS27–S813 FVS20UNV–S813 FVS23–S813 3⁄4⍯ 3⁄4⍯ 3⁄4⍯ Horizontal Wall Mount Vertical Wall Mount Accessories Separately Ordered ɀ Trunnion arm kit . . . . . . . . . . . . . . . . . FVS-K5 ɀ Slipfitter adapter to be used with trunnion arm . . . . . . . . . . . . . . . . . . . . . . SFA6 Dimensions: FVS with Trunnion Arm: 261⁄4⍯ × 13.5⍯W × 3.12⍯H Side View Top View FVS Showing Mounting Strap Positioning FVS With Lens Open US: 1-866-764-5454 STIBOINFO((CRH:66008com:6L:837)) CH0 5 L - 2 8 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds 837 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: 100: JOB: CRMAIN06-0838-2 Name: 6L-838 DATE: JAN 19 2006 Time: 5:55:48 PM Operator: TB FVS Series Long Twin Tube 6L COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 Photometric Data Fluorescent Luminaires Luminaire: FVS Lamp: (2) F40BX/SPX35/RS single-ended fluorescent. Total initial lumens: 6300 Isofootcandle Chart Coefficients of Utilization Effective Floor Cavity Reflectance 20% Eff. Ceil. 80* 70* 50* Footcandle Values for Isofootcandle Lines Mtg. Hgt. 8′ 10′ 12′ 16′ A 5.00 3.20 2.22 1.25 B 3.00 1.92 1.33 0.75 C 1.00 0.64 0.44 0.25 D 0.50 0.32 0.22 0.13 E 0.20 0.13 0.09 0.05 30* 10* 0* Wall 50* 30* 10* 50* 30* 10* 50* 30* 10* 50* 30* 10* 50* 30* 10* 0* 1 .621 .594 .569 .606 .582 .560 .580 .560 .541 .555 .539 .524 .533 .520 .507 .494 2 .538 .495 .459 .526 .487 .453 .503 .470 .442 .483 .455 .431 .464 .441 .421 .407 3 .469 .419 .378 .459 .412 .374 .441 .400 .367 .423 .389 .360 .407 .378 .353 .339 Room Cavity Ratio 4 5 6 .414 .367 .329 .359 .312 .273 .317 .270 .234 .405 .360 .323 .354 .308 .270 .314 .268 .232 .389 .347 .311 .345 .300 .265 .310 .265 .230 .374 .334 .301 .336 .293 .259 .305 .262 .227 .361 .322 .290 .327 .287 .254 .300 .258 .225 .286 .245 .212 * Percent Reflectance Spacing to Mounting Height Ratio Along lamp axis (A-A) 0.6 Across lamp axis (B-B) 1.1 * FVS suitable for Class II, Div. 1, Groups E, F, G when ordered with suffix S813. 838 STIBOINFO((CRH:66008com:6L:838)) CH0 5 L - 2 9 US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds 7 .297 .242 .204 .291 .240 .203 .281 .235 .201 .272 .230 .199 .264 .226 .197 .185 8 .269 .216 .180 .265 .214 .179 .256 .210 .178 .248 .207 .176 .241 .203 .175 .163 9 .246 .195 .160 .242 .193 .160 .234 .190 .159 .227 .187 .157 .221 .184 .156 .145 10 .225 .176 .144 .222 .175 .143 .216 .172 .143 .210 .170 .142 .204 .167 .141 .130 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-0839-3 Name: 6L-839 100: DATE: JAN 19 2006 EVFT Illuminator TM Long Twin Tube Fluorescent Luminaires Time: 5:55:49 PM Operator: TB COLOR: CMYK TCP: 15001 ɀ ɀ ɀ ɀ Cl. I, Div, Groups B & C(suffix GB), D Cl. I, Zone 1 Group IIB + H2(suffix GB), IIA ɀ Cl. II, Div 1, Groups E,F,G ɀ Cl. III Simultaneous Presence Typedriver Name: TS name csm no.: 100 Paint Spray Marine & Wet Locations ɀ 3,3R, 4,4X; IP66 6L Application: Illuminator TM compact fluorescent luminaires are used: ɀ In areas made hazardous by the presence of flammable gases and vapors, combustible dusts, or easily ignitable fibers and flyings. ɀ In areas where combustible dusts and flammable gases are present simultaneously. ɀ In applications involving low mounting heights, restricted mounting space, or where luminaire weight must be minimized. ɀ In areas where corrosion, vibration, moisture, dirt and rough usage are a problem. ɀ In refineries, chemical and petrochemical facilities, grain processing, handling and storage facilities, manufacturing plants, waste water treatment facilities, airline and mass transit maintenance areas, paint spray facilities, breweries, pharmaceutical plants and other areas where safe, reliable hazardous area lighting is required in a compact, cool operating and efficient light source. Features: ɀ Efficient fluorescent light source in 78 and 156 watts. ɀ Adjustable right and left asymmetrical reflectors provide excellent light ‘‘aimability’’ – ideal for task oriented lighting. ɀ Compact, light weight and low profile design allows easy installation and broad industrial application. ɀ Cast copper-free aluminum with epoxy powder finish (less than 0.4 of 1% copper) provides excellent resistance to corrosion. ɀ Versatile luminaire housing provides choice of pendant, wall or ceiling mount. ɀ Suitable for paint spray areas. Linear light source provides excellent color rendition for paint spray tasks. Easy to install, disposable, clear tube wrap helps maintain maximum light output during painting operations. ɀ Threaded construction, factory wiring and sealing help minimize installation time. No external seals are required. ɀ Fixtures are used with two or four long twin tube single-ended fluorescent lamps. ɀ Optional stainless steel guard provides extra protection for lamps and lamp tube. ɀ Optional clear polycarbonate tube provides 360° protection for lamps and lamp tube; ideal for maintenance pit and pharmaceutical applications. ɀ Grounding connection for safety. ɀ Available for 120 or 277 VAC. ɀ Standard electronic ballast. 4 lamp with stainless steel wire guard and adjustable reflectors Certifications and Compliances: Electrical Ratings: ɀ NEC and CEC: Class I, Division 1 Group D Class I, Division 1 Group B,C,D (suffix GB) Class I, Zone 1 Group IIA Class I, Zone 1 Group IIB + H2 (suffix GB) Class II Groups E,F,G Class III Simultaneous Presence (Cl. I and Cl. II) Paint Spray Note: Aiming Limitations Cl. II, Cl III & Simultaneous Presence – Aim Down to Horizontal – Cannot aim up ɀ UL Standards 844 Hazardous (Classified) Locations 1598 Luminaires 1598A Marine Locations ɀ CSA Standards C22.2 No. 137 ɀ Input voltage – 120 or 277 VAC, 60Hz ɀ Wattages – 78 – 2-lamp luminaire 156 – 4-lamp luminaire Options: Suffix to be added to Catalog Number ɀ Fused to protect circuit under abnormal conditions (not available on CSA certified luminaires). . . . . . . . . . . . . . . . . . . . . . . . . S658* ɀ Luminaire supplied with lamps . . . . . . . S714 ɀ Class I, Groups B and C suitability Pendant mount only! . . . . . . . . . . . . . . . . . GB Fixture Weights (lbs.): Illuminator – 2 lamp with guard . . . . . . . . . 19.5 Illuminator – 4 lamp with guards . . . . . . . . 36.5 RAL1, RAR1 reflectors (each) . . . . . . . . . . . . 3.0 Deduct for luminaire without P51 Guard: 1 lb. for 2 lamp 2 lbs. for 4 lamp Standard Materials: ɀ Center and ballast housings, end caps – copper-free aluminum ɀ Lamp tube – heat resistant glass. ɀ Guards – stainless steel or clear polycarbonate material. ɀ Reflectors – aluminum Standard Finishes: ɀ Center and ballast housings, end caps, guards – natural ɀ Reflectors – white epoxy finish Temperature Performance Data: Luminaire Type Minimum Operating Temp. Maximum Ambient Temp. Class I, Division 1 & Zone 1 Class II, Division 1 Simultaneous Presence Supply Wire 2 and 4 Lamp 10°C (50°F) 40°C (104°F) T4A 75°C * When ordering Fuses for luminaires, option S658, you must specify the operating voltage. S658 can not be ordered with /MT in the catalog number. US: 1-866-764-5454 STIBOINFO((CRH:66008com:6L:839)) CH0 5 L - 3 0 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds 839 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: 100: JOB: CRMAIN06-0840-2 Name: 6L-840 6L DATE: JAN 19 2006 EVFT Illuminator TM Long Twin Tube Fluorescent Luminaires Time: 5:55:53 PM Operator: TB COLOR: CMYK TCP: 15001 ɀ ɀ ɀ ɀ Cl. I, Div 1, Groups B & C (Suffix B),D Cl. I, Zone 1, Groups IIB + H2 (Suffix B), IIA ɀ Cl. II, Div 1, Groups E, F, G ɀ Cl. III, Simultaneous Presence Typedriver Name: TS name csm no.: 100 Paint Spray Marine & Wet Locations ɀ 3,3R, 4,4X; IP66 EVFT Illuminator Hub Size 3⁄4 2 Lamp 3 ⁄4 3⁄4 4 Lamp 3 ⁄4 Style Luminaire Voltage 120 277 120 277 Class I Cat. No. with Group D Suitability Without With Guard P51 Guard† EVFT22320 EVFT22321 EVFT22370 EVFT22371 EVFT24320 EVFT24321 EVFT24370 EVFT24371 Class I Cat. No. with Group B, C & D Suitability Without With Guard P51 Guard† EVFT22320–GB EVFT22321–GB EVFT22370–GB EVFT22371–GB EVFT24320–GB EVFT24321–GB EVFT24370–GB EVFT24371–GB † P51 supplied in separate carton. Accessories ɀ Stainless steel wire guard . . . . . . . . . . . . P51 ɀ Reflector right hand . . . . . . . . . . . . . . . . RAR1 ɀ Reflector left hand . . . . . . . . . . . . . . . . . . RAL1 ɀ Polycarbonate tube . . . . . . . . . . . . . . . . . PG1 (not used with optional stainless steel wire guard) ɀ Disposable clear wrap – 5 pack. . . . . . PTW1 (for use with optional polycarbonate tube) Note: Aiming Limitations: In Class II, Class III and Simultaneous Presence locations ɀ Aim down to Horizontal. ɀ To prevent dust from accumulating in reflector, do not aim up. Dimensions Illuminator two lamp luminaire with Reflector RAR1 RAL1 Reflectors (as viewed facing front of fixture). Stainless steel guard Illuminator four lamp luminaire with Reflectors Polycarbonate tube and retaining plate ɀ For GB suffix (Groups B & C) this dimension is 34.0⍯. For CSA certified fixtures this dimension is 359⁄16⍯. ɍ For GB suffix (Groups B & C) this dimension is 8.38⍯. Disposable polyester tube wrap (used over optional polycarbonate tube) 840 STIBOINFO((CRH:66008com:6L:840)) CH0 5 L - 3 1 US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: 100: JOB: CRMAIN06-0841-3 Name: 6L-841 DATE: JAN 19 2006 Time: 5:55:55 PM Operator: TB COLOR: CMYK TCP: 15001 Photometric Data EVFT Illuminator TM Long Twin Tube Typedriver Name: TS name csm no.: 100 6L Fluorescent Luminiaires Illuminator two lamp luminaire with Reflector (without Guard) Lamps: (2) 39 watt BIAX* fluorescent DEGREES 0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 CANDELAS in Plane A-A LEFT RIGHT 729 729 792 797 820 821 757 777 648 709 567 632 474 535 340 469 201 312 102 116 9 7 Plane B-B SIDE 729 703 658 582 488 370 239 109 21 LEGEND PLANE A-A ACROSS LAMP AXIS – – – – PLANE B-B ALONG LAMP AXIS Footcandle Values for Isofootcandle Lines MTG. HT (FT) A B C D E F 8 10.0 5.00 2.00 1.00 0.50 0.25 10 6.4 3.20 1.28 0.64 0.32 0.16 12 4.4 2.22 0.89 0.44 0.22 0.11 16 2.5 1.25 0.50 0.25 0.13 0.06 Illuminator four lamp luminaire with Reflectors (without Guards) Lamps: (4) 39 watt BIAX* fluorescent DEGREES 0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 CANDELAS in Plane A-A LEFT RIGHT 1486 1486 1601 1520 1633 1615 1570 1602 1530 1558 1343 1390 1162 1208 803 921 375 488 136 168 13 18 2 6 1 4 2 1 2 2 1 2 Plane B-B SIDE 1486 1448 1346 1199 1000 763 492 225 45 2 1 1 1 1 1 2 LEGEND PLANE A-A ACROSS LAMP AXIS – – – – PLANE B-B ALONG LAMP AXIS Footcandle Values for Isofootcandle Lines MTG HT (FT) A B C D E F 10 8.0 4.00 2.00 1.00 0.50 0.20 12 5.6 2.78 1.39 0.69 0.35 0.14 16 3.1 1.56 0.78 0.39 0.20 0.08 20 2.0 1.00 0.50 0.25 0.13 0.05 * BIAX is a trademark of the General Electric Company. US: 1-866-764-5454 STIBOINFO((CRH:66008com:6L:841)) CH0 5 L - 3 2 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds 841 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: 100: JOB: CRMAIN06-0842-2 Name: 6L-842 DATE: JAN 19 2006 Time: 5:55:56 PM Operator: TB TCP: 15001 Typedriver Name: TS name csm no.: 100 Coefficients of Utilization EVFT Illuminator TM Long Twin Tube 6L COLOR: CMYK Fluorescent Luminaires LUMINAIRE: EVFT 22320 with RAR1 Reflector Lamps: Two (2) F39BX/SPX35/RS Lumen Rating: 2900 Lumens/Lamp Effective Floor Cavity Reflectance 20% % Reflectance Eff. Ceil. Wall 0 1 2 3 Room Cavity Ratio 4 5 6 7 8 9 10 80 70 50 30 10 .51 .51 .51 .51 .46 .44 .41 .40 .41 .38 .35 .32 .38 .33 .29 .26 .34 .29 .25 .22 .31 .25 .21 .18 .29 .23 .19 .16 .26 .20 .16 .14 .24 .18 .14 .12 .22 .16 .13 .10 .21 .15 .11 .09 70 70 50 30 10 .49 .49 .49 .49 .45 .43 .41 .39 .40 .37 .34 .31 .37 .32 .29 .26 .33 .28 .25 .22 .30 .25 .21 .18 .28 .22 .18 .16 .26 .20 .16 .14 .24 .18 .14 .12 .22 .16 .12 .10 .20 .14 .11 .09 50 50 30 10 .47 .47 .47 .41 .39 .38 .35 .33 .31 .31 .28 .26 .27 .24 .22 .24 .21 .18 .21 .18 .16 .19 .16 .13 .17 .14 .12 .15 .12 .10 .14 .11 .09 30 50 30 10 .45 .45 .45 .39 .38 .37 .34 .32 .30 .30 .27 .25 .26 .24 .21 .23 .20 .18 .21 .18 .15 .19 .16 .13 .17 .14 .11 .15 .12 .10 .14 .11 .09 10 50 30 10 .43 .43 .43 .37 .36 .35 .33 .31 .29 .29 .27 .25 .25 .23 .21 .22 .20 .18 .20 .17 .15 .18 .15 .13 .16 .13 .11 .14 .12 .10 .13 .10 .08 0 0 .43 .35 .28 .24 .20 .17 .14 .12 .10 .09 .08 DETERMINED IN ACCORDANCE WITH CURRENT IES PUBLISHED PROCEDURES LUMINAIRE: EVFT 24320 with RAR1 & RAL1 Reflectors Lamps: Four (4) F39BX/SPX35/RS Lumen Rating: 2900 Lumens/Lamp Effective Floor Cavity Reflectance 20% % Reflectance Eff. Ceil. Wall 0 1 2 3 Room Cavity Ratio 4 5 6 7 8 9 10 80 70 50 30 10 48 .48 .48 .48 .44 .42 .40 .39 .40 .37 .34 .31 .37 .32 .29 .26 .33 .29 .25 .22 .30 .25 .21 .19 .28 .22 .19 .16 .26 .20 .16 .14 .24 .18 .14 .12 .22 .16 .13 .10 .20 .15 .11 .09 70 70 50 30 10 .47 .47 .47 .47 .43 .41 .40 .38 .39 .36 .33 .31 .36 .32 .29 .26 .33 .28 .25 .22 .29 .25 .21 .18 .27 .22 .18 .16 .25 .20 .16 .14 .23 .18 .14 .12 .21 .16 .12 .10 .20 .14 .11 .09 50 50 30 10 .45 .45 .45 .39 .38 .37 .34 .32 .30 .30 .28 .26 .27 .24 .22 .24 .21 .18 .21 .18 .16 .19 .16 .14 .17 .14 .12 .15 .12 .10 .14 .11 .09 30 50 30 10 .43 .43 .43 .38 .37 .36 .33 .31 .30 .29 .27 .25 .26 .23 .21 .23 .20 .18 .20 .18 .16 .18 .16 .13 .17 .14 .12 .15 .12 .10 .14 .11 .09 10 50 30 10 .41 .41 .41 .36 .35 .35 .32 .30 .29 .28 .26 .25 .25 .23 .21 .22 .20 .18 .20 .17 .15 .18 .15 .13 .16 .13 .12 .14 .12 .10 .13 .11 .09 0 0 .41 .34 .28 .24 .20 .17 .15 .13 .11 .09 .08 DETERMINED IN ACCORDANCE WITH CURRENT IES PUBLISHED PROCEDURES 842 STIBOINFO((CRH:66008com:6L:842)) CH0 5 L - 3 3 US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: 100: JOB: CRMAIN06-0843-11 Name: 6L-843 DATE: JAN 19 2006 Time: 5:55:57 PM Operator: JB COLOR: CMYK ɀ ɀ ɀ ɀ Higher Ambient Suitability: 55°C Cold Weather Start (32W T8 Lamps) ɀ Cl. I, Div 2, Groups A, B, C, D ɀ Cl. I, Zone 2 Group IIC NFL Series Fluorescent Luminaires TCP: 15001 Typedriver Name: TS name csm no.: 100 Wet Locations 3, 3R, 4, 4X 6L Application: The NFL light luminaires are used: ɀ In non-hazardous locations where dust, dirt, combustible vapors, smoke, fumes, moisture, corrosive & wet conditions are present. ɀ Where lamps may be broken due to physical abuse or movable equipment, such as in manufacturing areas or warehouses. ɀ Where cleanliness and sanitation are prime factors such as in dairies, canneries, food processing plants, bottling plants & laboratories. ɀ In dock areas for protection against salt spray. ɀ In areas where low mounting height and the even light distribution associated with a line type light source are required. Standard Materials: ɀ Housing – Non-metallic, one piece fiberglass reinforced polyester ɀ Latches – Celcon TM acetal plastic ɀ Crepe Pattern Lens – Acrylic plastic ɀ Gasket – Seamless thermoset polyurethane ɀ Mounting Bracket – Stainless steel Standard Finishes: ɀ Fiberglass housing – White ɀ Acrylic Plastic lens – Clear Key Features ɀ Molded in place mounting studs – eliminate the need of bracket gaskets ɀ Standard construction includes: S.S. mounting brackets Electronic ballast Cold weather ballast (4′ F32 T8) ɀ S.S. mounting bracket Combination ceiling & chain Certifications and Compliances: ɀ UL Listed 844 ɀ cUL ɀ Wet locations ɀ 4X Ratings (Electrical/Size): Sources/Wattage: Luminaires are for use with the following lamps ɀ NFL2140 – one 40 W long twin tube ɀ NFL4232 – two 32W T8 lamps ɀ NFL4240 – two 34W ‘‘F40 Style’’ T12 lamps Voltages ɀ 120V 60Hz ɀ 120 - 277V, 50 - 60 Hz ɀ 347V 60Hz Conduit Entries ɀ Two 1⁄2⍯ inch Myers hubs, one on each end. ɀ S.S. mounting brackets ɀ Electronic Ballast ɀ Cold Weather Ballast (4′ F32 T8) ɀ Two 1⁄2⍯ conduit Myers hubs for end and feed through wiring ɀ Full metal fixture interior ɀ Provisions (drill mark) on 4 ft. unit to field drill for pendant mounting Options: Description Suffix to be added to Cat. No. ɀ Fused . . . . . . . . . . . . . . . . . . . . . . . . .S658‡ ɀ Factory assembled with lamps installed . . . . . . . . . . . . . . . . . . . . . . . . .FA ɀ Battery Backup Emergency Ballast † (NFL 2140 and NFL 4232 only) . . . . .S799* ɀ Increased Impact-Resistant Acrylic Lens . . . . . . . . . . . . . . . . . . . . .DR1295046* ɀ Polycarbonate Lens . . . . . . . . . . . . .DR1295306* ɀ Stainless Steel Latches . . . . . . . . . .S863* ɀ Tamperproof Latches . . . . . . . . . . .S861* – available with Lightning Service TMdelivery See Section G for complete details † For non-hazardous locations ‡ When ordering Fuses for luminaires, option S658, you must specify the operating voltage. S658 can not be ordered with /MT in the catalog number. * UNV voltages: 120, 208, 230, 240, 277, 50-60 Hz US: 1-866-764-5454 STIBOINFO((CRH:66008com:6L:843)) CH0 0 5 L - 3 Benefits ɀ UL, cUL Listed for Class I, Division 2, Groups A, B, C, D areas with ambient suitability of 40°C (104°F) and 55°C (131°F) Ambient suitability ɀ NEMA 4X with Myers Hubs and threaded metal plug (furnished) ɀ Non-metallic construction enclosure ɀ Continuous form in place gasket Suitable for higher ambients found in industrial environments. Exceeds the 25°C (77°F) ambient suitability of ordinary location lighting fixtures. Outdoor locations, hose down and corrosive environments suitable. Corrosion resistant. Insure dust tight, moisture tight, & wet locations integrity. Wet locations, and dust tight integrity is not compromised by aging or deteriorated bracket gaskets. Eliminates the need to order options with associated long lead times. Standard bracket not only surface mounts fixture, but also is for chain mounting using standard commercially available fixture chain. Superior corrosion resistance. Energy efficiency. Cold weather start up requirements. Simplify installation and wiring. Provides improved photometrics as well as access to & concealment of ballast and wiring. Application and installation flexibility. Temperature Performance Data: Ambient temperature range suitability: ɀ Two lamp, 32W T8, 4 ft luminaire –18°C to 55°C ɀ ALL others 0°C to 55°C ɀ Supply wire 75°C min. Celecon TM is a trade name of Hoechst Celanese Ordering Information: Luminaire Cat # Size/# of lamp(s) Wattage/Lamp type Voltage/Hz NFL2140/UNV 2 ft/ 1-lamp 40W T5 compact 120/60 NFL2140/347 single ended 120-277/50-60 347/60 NFL4232/UNV 4 ft/2-lamp 32W T8 120/60 rapid start 120-277/50-60 NFL4240/120 4ft/2-lamp 34W T12 120/60 NFL4240/277 ‘‘F40 Style’’ 277/60 NFL4240/347 rapid start 347/60 N2FL4232/UNV N2FL4232/347 4ft/2-lamp 32W T8 347/60 rapid start CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds 843 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-0844-2 Name: 6L-844 6L 100: DATE: JAN 19 2006 Time: 5:55:58 PM Operator: TB COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 Photometric Data NFL Series Fluorescent Luminaires Luminaire: All NFL Luminaires To determine number and placement of luminaires, see Lighting Selector Guide in Section L Candlepower Distribution Curve (in Candelas) CANDELAS Angle Along Across 0° 1049 1049 10° 1034 1056 20° 978 1071 30° 866 1075 40° 762 1027 50° 606 939 60° 416 838 70° 228 723 80° 92 549 90° 17 363 100° 19 243 110° 10 131 120° 5 46 130° 4 20 140° 4 9 150° 4 3 160° 4 0 170° 0 0 180° 0 0 ZONAL LUMENS Zone Lumens 0–30 862 0–40 1462 0–60 2778 0–90 4130 0–180 4499 Photometric data, developed using two (2) F32T8/35K 2850 lumen lamps, represents the performance of all NFL series luminaires. ɀ Coefficient of Utilization – These values are for all NFL series luminaires (Do not use multipliers). ɀ Candlepower Distribution Cuarve (in candelas) and Zonal Lumens – These values are for all NFL series luminaires, adjusted by conversion factors (multipliers) below. Luminaire Lamp Series Qty Watts NFL4232 2 32 NFL4240 2 34 NFL2140 1 40 Type (Lumens ea.) F32T8/35K (2850) F40T12/RS (2650) T5 Compact (3150) Conversion Factor (multipliers) 1.0 0.93 0.55 Example: ɀ Candlepower at 20° across for NFL4232 using 2F32T/35K lamps (5700 lumen total) is 1071 candelas. ɀ Candlepower at 20° across for NFL2140 using 1 T5 compact lamp (3100 lumen total) is 1071 x .55 ⍧ 589 candelas. Coefficient of Utilization: For all NFL Series Light Luminaires Effective Floor Cavity Reflectance 20% % REFLECTANCE Eff. Ceiling Wall 70 80 50 30 10 70 70 50 30 10 50 50 30 10 50 30 30 10 50 10 30 10 0 0 844 STIBOINFO((CRH:66008com:6L:844)) CH0 0 5 L - 4 1 .83 .78 .74 .71 .80 .76 .72 .69 .71 .68 .66 .67 .65 .62 .63 .61 .59 .57 2 .75 .67 .61 .56 .72 .65 .60 .55 .61 .57 .53 .58 .54 .51 .54 .51 .48 .46 US: 1-866-764-5454 3 .68 .59 .52 .46 .65 .57 .51 .46 .54 .48 .44 .51 .46 .42 .48 .44 .41 .39 4 .62 .52 .44 .39 .59 .50 .43 .38 .47 .42 .37 .45 .40 .36 .42 .38 .35 .33 CAN: 1-800-265-0502 ROOM CAVITY RATIO 5 6 .56 .51 .45 .40 .38 .33 .32 .28 .54 .49 .44 .39 .37 .32 .32 .27 .42 .37 .35 .31 .31 .26 .39 .35 .34 .30 .30 .26 .37 .33 .33 .29 .29 .25 .27 .23 7 .47 .36 .29 .24 .46 .35 .28 .23 .33 .27 .23 .32 .26 .22 .30 .25 .22 .20 Copyright© 2006 Cooper Crouse-Hinds 8 .44 .32 .25 .20 .42 .31 .25 .20 .30 .24 .20 .28 .23 .19 .27 .22 .18 .17 9 .40 .29 .22 .17 .39 .28 .22 .17 .27 .21 .17 .25 .20 .16 .24 .19 .16 .14 10 .37 .26 .20 .15 .36 .26 .19 .15 .24 .19 .15 .23 .18 .14 .22 .17 .14 .12 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-0845-5 Name: 6L-845 100: DATE: JAN 19 2006 Time: 5:55:59 PM Operator: JB COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 Dimensions and Weights NFL Series Fluorescent Luminaires 6L Dimensions: Net Luminaire Weights (lbs) Luminaire Series NFL2140 NFL4232 NFL4240 Weight (lbs.) 9.1 14.3 14.3 Temperature Performance Data Basic Watts Cat # Ambient Temp °C Lamp Type Supply Wire Temp °C Class I, Div. 2 Temp. Rating Class II Temp. Rating NFL4232 NFL4232 NFL4240 NFL4240 NFL2140 NFL2140 40 55 40 55 40 55 T8 T8 T12 T12 T12 T12 60 75 60 75 60 75 T6 T5 T6 T5 T6 T5 - 32 32 34 34 40 40 US: 1-866-764-5454 STIBOINFO((CRH:66008com:6L:845)) CH0 0 5 L - 5 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds Simultaneous Presence Class 1, Div. 2 - 845 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: 100: JOB: CRMAIN06-0846-11 Name: 6L-846 6L DATE: JAN 19 2006 Time: 5:56:00 PM Operator: GK COLOR: CMYK TCP: 15001 ɀ ɀ ɀ ɀ Cl. I, Div 2, Groups B,C,D Cl. I, Zone 1 Group IIC ɀ Cl. II, Div Groups E,F,G(Canada) ɀ Cl. II, Div 2, Groups F,G (US) ɀ Cl. III, Simultaneous Presence eLLK Series Fluorescent Nonmetallic Luminaires Typedriver Name: TS name csm no.: 100 Wet Locations 3,3R,4,4X; IP66 ɀ ATEX Certified Application: ɀ eLLK fixtures are used in hazardous area where moisture or corrosion may be a problem. ɀ Offshore oil platforms, Pharmaceuticals, plants, Oil refineries. ɀ Where battery backup is critical. ɀ In non-hazardous and industrial locations. Features: ɀ IEC: Zone 1 and 2 areas. ɀ NEC/CEC: Zone 1, Division 2 areas. ɀ Electronic Ballast: ɀ Operates at Voltage range of 110-254 VAC ± 10%, 50-60Hz. ɀ Lower ambient temperature suitability to –25°C. ɀ Lamps operate indepenently - one lamp failure will not effect remaining lamp operation. ɀ Standard Bi-pin Lamps - Most common lamp used in office enviroments. Energy efficient and cost effective. ɀ Interlocked Switch - Automatically cuts power to both lamps and ballast when the lens is opened. ɀ Removable Lens - Hinged on both sides for easy installation and maintenance. ɀ Dual entries - Extra large wire well eliminates need for seperate junction boxes. (Own with cable gland and conduit hub). ɀ Corrosion-Resistant Construction - Nonmetallic body, gasketed lenses, and lens locking system for an IP 66, NEMA 4X rating. ɀ Battery Backup Features: ɀ Operates one lamp for 11⁄2 hours should power go out. ɀ Microprocessor monitors the charging functions of the battery. ɀ LEDs provide visual indication of battery life. Certifications and Compliances: ɀ NEC and CEC: Class I, Division 2 Group B, C, D Class I, Zone 1 Group IIC Class II Division 1, Groups E,F,G (Canada) Class II Division 2, Groups F, G (US) Class III, Simultaneous Presence (Cl. I and Cl. II) ɀ UL Standards 2279 Hazardous (Classified) Locations 1598 Luminaires ɀ CSA Standards E79 Series II 2 G ɀ ATEX Directive 94/9/EC II 2 D T80°C ɀ Type of Protection EEx edm ib IIC T4 ɀ EC-Type Examination PTB 96 ATEX 2144 Certificate Ordering Information: Type - 2 Lamp 18W 36W 18W 18W (with battery) 18W (with battery) 36W 36W (with battery) 36W (with battery) Length & Type 2-foot T8 4-foot T8 2-foot T8 2-foot T8 2-foot T8 4-foot T8 4-foot T8 4-foot T8 Conduit Hub Size* M25 metric hub M25 metric hub 3/4⍯ Myers hub 3/4⍯ Myers hub 3/4⍯ Myers hub 3/4⍯ Myers hub 3/4⍯ Myers hub 3/4⍯ Myers hub Rated Current 0.18A 0.34A 0.18A 0.23A 0.23A 0.34A 0.40A 0.40A Rated Voltage ±10%, 47-63Hz 110-254 110-254 110-254 110-120 220-254 110-254 110-120 220-254 Order Number 1 2265 875 103 1 2266 875 103 1 2265 875 311 1 2260 879 333 1 2260 879 311 1 2266 875 311 1 2261 879 333 1 2261 879 311 Description eLLK92018/UNV eLLK92036/UNV eLLK92018/UNV eLLK92018/18/NIB eLLK92018/18/NIB WH eLLK92032/UNV eLLK92036/36/NIB eLLK92036/36/NIB * 2 hubs provided. May be connected throughfeed or tandam. Cable glands ordered separately for 3⁄4⍯ (remove hubs) or M 25 openings (remove hubs). Lamp Selection: Phillips GE Osram/Sylvania 846 STIBOINFO((CRH:66008com:6L:846)) CH0 5 L - 3 0 Weight 17W 32W F17T8/Tl841 F17T8/SPX41 F017/841 F32T8/TL841 F32T8/SPX41 FO32/841 US: 1-866-764-5454 CAN: 1-800-265-0502 17 W 17 W (battery) 32 W 32 W Copyright© 2006 Cooper Crouse-Hinds 4.6 Kg (10 Ib) 10 Kg (22 Ib) 6.7 Kg (14 Ib) 12 Kg (26 Ib) Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-0847-4 Name: 6L-847 100: DATE: JAN 19 2006 Time: 5:56:01 PM Operator: JB TCP: 15001 Typedriver Name: TS name csm no.: 100 Accessories Dimensions eLLK Series TM Fluorescent Nonmetallic Luminaires Accessories COLOR: CMYK 6L Dimensions: (mm) Standard Luminaire with Backup Eyebolt Hexagonal Screw Type Eyebolt Hexagon Screw S4 Ceiling Mounting D92 Bracket Pipe Clamp Ceiling Mounting Bracket Corrosion Protection Galvanized Cr Ni Pipe Outer Quantity per Din OD (mm) Luminaire — — 2 — — 2 Order Number 2 2480 002 000 2 2480 054 000 Cr Ni R12 Hot Galvanized R14 CrNi R22 Hot Galvanized R32 Hot Galvanized — 11⁄4⍯ 11⁄4⍯ 11⁄2⍯ 2⍯ — 38–42 38–42 47–51 56–60 2 2 2 2 2 2 2480 092 000 2 2480 462 000 2 2480 464 000 2 2480 472 000 2 2480 482 000 — — — — 3 2485 000 005 Hexagon Key SW13 eLLK 92 Pipe Clamp Wall Bracket US: 1-866-764-5454 STIBOINFO((CRH:66008com:6L:847)) CH0 5 L - 3 0 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds 847 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: 100: JOB: CRMAIN06-0848-2 Name: 6L-848 DATE: JAN 19 2006 Time: 5:57:02 PM Operator: TB TCP: 15001 Typedriver Name: TS name csm no.: 100 Photometric Data eLLK Series TM Fluorescent Nonmetallic Luminaires 6L COLOR: CMYK Photometric data developed using 2 – F32T8 3350 lumen lamps. For the 17 W eLLK, use a 0.45 multiplier. Coefficients of Utilization Effective Floor Cavity Reflectance 20% Wall 70* 50* 30* 10* Work 20* 20* 20* 20* Room Cavity Ratio 1 2 3 41 49 55 30 38 44 23 30 36 18 25 30 4 61 50 43 37 5 65 55 48 42 6 70 62 55 50 7 74 67 61 56 8 77 71 65 61 9 80 75 70 66 70* 50* 30* 10* 20* 20* 20* 20* 40 29 22 18 47 37 30 24 53 42 35 30 58 49 42 36 62 54 47 42 68 60 54 49 71 65 59 54 74 68 64 59 77 72 68 64 50* 50* 30* 10* 20* 20* 20* 27 21 17 35 28 24 40 34 29 46 40 35 50 45 40 56 51 47 61 56 52 64 60 57 68 64 61 30* 50* 30* 10* 20* 30* 20* 26 20 17 38 27 23 37 32 28 43 38 34 47 43 39 58 49 45 57 53 50 60 57 54 64 61 58 10* 50* 30* 10* 20* 20* 20* 24 20 16 31 26 22 35 31 27 41 36 33 45 41 37 50 46 43 54 51 48 57 54 52 60 68 55 0* 0* 20* 14 20 25 31 35 41 46 49 53 Eff. Ceil. 80* 70* * Percent Reflectance 848 STIBOINFO((CRH:66008com:6L:848)) CH0 5 L - 3 0 US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-0849-16 Name: 6L-849 100: DATE: JAN 19 2006 Time: 5:57:03 PM Operator: JB COLOR: CMYK CI.I, Div. 2, Groups A,B,C,D CI.I, Zone 2 Aex nA II CI.II, Division 2, Groups F,G Enclosure Type 4X nLLK Series Nonmetallic Flourescent Luminaires TCP: 15001 Typedriver Name: TS name csm no.: 100 Wet Locations UL and cUL Listed ATEX Certified 6L The Cooper Crouse-Hinds SpecOne TM nLLK Series Fluorescent Luminaire is an ideal source of general illumination indoors or out, in ordinary or hazardous environments. Its heavy-duty, nonmetallic construction stands up to tough physical and environmental demands, making it an excellent choice where dust, dirt, gas, vapor, smoke, fumes, moisture, corrosive and wet conditions are present. As with all SpecOne products, the nLLK luminaire meets the standards and codes of regulating agencies throughout the world, which simplifies product specifying for multinational users. APPLICATIONS nLLK series luminaires are used: In indoor or outdoor, ordinary or hazardous areas Where a heavy-duty, nonmetallic luminaire is required to hold up to tough physical and environmental demands including corrosives, water, dust and extreme temperatures ɀ manufacturing plants ɀ heavy industrial facilities ɀ industrial process facilities ɀ refineries ɀ chemical ɀ petrochemical ɀ pharmaceutical ɀ waste water and sewage treatment plants In areas where low mounting height, immediate full illumination, and the even light distribution associated with a linetype light source are required ɀ loading docks ɀ tunnels ɀ stairways Where wet location or Type 4X protection is required ɀ dock areas ɀ production platforms In hosedown areas where cleanliness and sanitation are prime factors ɀ dairies ɀ canneries ɀ food processing plants ɀ bottling plants ɀ laboratories CERTIFICATIONS & COMPLIANCES NEC ɀ Class I, Division 2, Groups A, B, C, D ɀ Class I, Zone 2 AEx nA II ɀ Class II, Division 2, Groups F, G ɀ Wet Locations ɀ UL Listed CEC ɀ Class I, Zone 2 Ex nA II ɀ Class I, Division 2, Groups A, B, C, D ɀ Class II, Division I, Groups E, F, G ɀ cUL Listed (certified by UL) Enclosure ɀ Type 4X ɀ IP65 UL Standards ɀ 2279 Hazardous (Zones Classified) Locations ɀ 1598 Luminaires CSA Standards ɀ C22.2 No. 9 ɀ CAN/CSA–E79-15 STIBOINFO((CRH:66008com:6L:849)) ɀ one-piece housing—fiber-glass reinforced polyester ɀ lens—polycarbonate ɀ gasket—silicone STANDARD FINISHES ɀ fiberglass housing—natural (white) ɀ lens—natural (clear) RATINGS (ELECTRICAL/ SIZE) Sources/Wattages ɀ two 17 W or two 32 W linear fluorescent Voltages ɀ 120–277 V, 50–60 Hz. ɀ 347 V, 60 Hz.—consult factory Hub Size ɀ four 25 mm entries, two on each end, three plugged ɀ two Myers® STM2 25 mm to 3⁄4⍯ NPT adapter hubs provided standardfor throughfeed or tandem wiring ATEX ɀ ATEX Directive 94/9/EC ɀ Type of Protection ɀ EC-Type Examination Certificate ɀ EC-Type Examination Certificate US: 1-866-764-5454 CH0 5 L - 3 0 STANDARD MATERIALS CAN: 1-800-265-0502 II 3 G II 2 D/II 3 D T80°C EEx nA II T4 nach EN 50021 PTB 96 ATEX 2208 DMT 02 ATEX E116 Copyright© 2006 Cooper Crouse-Hinds 849 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: 100: JOB: CRMAIN06-0850-23 Name: 6L-850 6L DATE: JAN 19 2006 Time: 5:57:04 PM Operator: JB COLOR: CMYK TCP: 15001 CI.I, Div. 2, Groups A,B,C,D CI.I, Zone 2 Aex nA II CI.II, Division 2, Groups F,G Enclosure Type 4X nLLK Series Nonmetallic Flourescent Luminaires Typedriver Name: TS name csm no.: 100 Wet Locations UL and cUL Listed IP65, Type 4X heavy-duty construction ɀ nonmetallic body, gasketed lens and unique labyrinth lens locking system ɀ dust-tight, water-tight and moisture-tight ɀ corrosion and impact-resistant ɀ ideal for outdoor applications Electronic ballast ɀ lower ambient temperatures suitability to -18°C ɀ high–power factor ballast (+90%) allows for more luminaires per circuit Standard T8 bi-pin lamps—most common lamp used; energy-efficient and cost-effective Removable lens—hinged on both sides for easy installation and maintenance Easy wiring and installation— ɀ four 25 mm entries. Two Myers® 3⁄4⍯ NPT adapter hubs supplied standard ɀ suitable for through-feed or tandem applications ɀ extra-large wire well eliminates need for separate junction boxes Worldwide suitability ɀ NEC/CEC: Class I, Zone 2 and Division 2 areas ɀ IEC/CENELEC certified luminaires available. Consult factory. ORDERING INFORMATION HUB SIZE* 3⁄4⍯ NPT 3⁄4⍯ NPT * 25 mm entries—supplied with two Myers LAMP DESCRIPTION 17 W T8, Rapid Start—2 lamps 32 W T8, Rapid Start—2 lamps ® VOLTAGE/HZ. 120–277 V, 60 Hz. 120–277 V, 60 Hz. CATALOG NO. nLLK98 2217/UNV nLLK98 4232/UNV STM2 25 mm to 3⁄4⍯ NPT adapter hubs. ACCESSORIES DESCRIPTION SW13 hexagon key (for maintenance and lamp replacement) Myers® 25 mm to 3⁄4⍯ NPT adapter hub CATALOG NO. 3 2485 000 005 STM2 MOUNTING ACCESSORIES TYPE CORROSION PROTECTION Eyebolt A2 Galvanized Hexagon Screw S4 (to attach ceiling mounting bracket or pipe clamp to Nickel Chromium luminaire) Ceiling Mounting Bracket D92 Nickel Chromium Pipe Clamp R12 Hot Galvanized Pipe Clamp R14 Nickel Chromium Pipe Clamp R22 Hot Galvanized Pipe Clamp R32 Hot Galvanized 850 STIBOINFO((CRH:66008com:6L:850)) CH0 5 L - 3 0 US: 1-866-764-5454 PIPE DIN 11⁄4⍯ 11⁄4⍯ 11⁄2⍯ 2⍯ CAN: 1-800-265-0502 OUTER DIA. 38–42 mm 38–42 mm 47–51 mm 56–60 mm QTY. PER LUMINIARE 2 CATALOG NO. 2 2480 002 000 2 2 2 2 2 2 2 2480 054 000 2 2480 092 000 2 2480 462 000 2 2480 464 000 2 2480 472 000 2 2480 482 000 Copyright© 2006 Cooper Crouse-Hinds Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-0851-27 Name: 6L-851 100: DATE: JAN 19 2006 Time: 5:57:05 PM Operator: JB COLOR: CMYK CI.I, Div. 2, Groups A,B,C,D CI.I, Zone 2 Aex nA II CI.II, Division 2, Groups F,G Enclosure Type 4X nLLK Series Nonmetallic Flourescent Luminaires TCP: 15001 Typedriver Name: TS name csm no.: 100 Wet Locations UL and cUL Listed 6L PHOTOMETRIC DATA TEMPERATURE PERFORMANCE Minimum Starting Temperature: -18°C WATTS AMBIENT CLASS I, DIV. 2 (CLASS I, ZONE 2) CLASS II, DIV. 1 (CEC) CLASS II, DIV. 2 (NEC) SUPPLY WIRE TEMP °C Two 17 W T8 lamps Two 32 W T8 lamps 40°C 40°C T4 T4 T6 T6 60 60 Eyebolt MAINTENANCE AND RELAMPING (eLLK Series Div. 1/Zone 1 luminaire is shown. Maintenance procedures are the same for the nLLK.) Hexagon Screw 1. One quarter turn with the SW13 hexagon key or a 5⁄16⍯ (M8) Allen hex head wrench releases multiple locking points. 2. Lamps can be stored in open lens, freeing up hands for easy relamping. 3. Replace the bi-pin lamp, lock with one quarter turn of the wrench for an IP65, Type 4X seal. Ceiling Mounting Bracket DIMENSIONS (mm) & WEIGHT Weight: 8.8 lbs. (4.0 kg.)—17 W 13.2 lbs. (6.0 kg.)—32 W Pipe Clamp US: 1-866-764-5454 STIBOINFO((CRH:66008com:6L:851)) CH0 5 L - 3 0 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds 851 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-0852-23 Name: 6L-852 6L 100: DATE: JAN 19 2006 Time: 5:57:07 PM Operator: RB COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 CI.I, Div. 2, Groups A,B,C,D Wet Locations CI.I, Zone 2 Group IIC NEMA 3,3R CI.II, Div. 1, Groups F,G CI.III & Simultaneous Presence FVN Series Flourescent Luminaires Certifications and Compliances: NEC and CEC: ɀ Class I, Division 2 Groups A, B, C & D ɀ Class I, Zone 2 Groups IIC ɀ Class II, Division 1 Groups F, G ɀ Class III ɀ Simultaneous Presence (Cl. I and Cl. II) UL Standards: ɀ 844 Hazardous (Classified) Areas ɀ 1598 Luminaires CSA Standards: ɀ C22.2 NO. 137 FVN Luminaires are ideal for use: ɀ In areas made hazardous by the abnormal conditions resulting in the presence of flammable vapors or gases and combustible dusts as defined by the National Electrical Code®. ɀ Where broken lamps would damage machinery or processes, or harm people working in the area. ɀ In areas where stringent sanitation requirements exist. Standard Materials: ɀ Luminaire housing - 20-gauge seamless sheet steel ɀ Lens/Frame Assembly - stainless steel ɀ Glass - 3/16” tempered ɀ Suspension flanges - seamless sheet steel ɀ Gaskets - silicone ɀ Lamphoders - white thermoset plastic ɀ Clamps - stainless steel Features ɀ One-piece seamless sheet steel housing with welded end caps keeps dirt, dust and moisture away from ballast and lamps. Easy to clean. ɀ A silicone rubber gasket provides a dust-tight seal between the lens/frame assembly and housing. ɀ Lens/frame assembly is hinged and wireway cover is held by safety chain for ease of lamp replacement and maintenance. ɀ Polyester powder coat finish provides high reflectance and corrosion resistance for long life and dependable service. ɀ Two 1⁄2” NPT pendant hubs and two 1⁄2” NPT thru-feed end hubs are standard. ɀ Electronic ballast is standard on 32, 40(/UNV only) and 54 watt luminaires. FVN Fluorescent Luminaires with T5 HO lamps offer... ɀ High lumen output per watt - provides energy savings versus other higher wattage fluorescent luminaires with similar lumen output. ɀ Longer lamp life and good lumen maintenance - reduced maintenance and lamp replacement costs. Standard Finishes: ɀ Reflector housings - corrosion resistant white polyester powder coat ɀ Lens/Frame - natural Dimensions: Ordering Information (Lamps not supplied): Supercedes ordering information in Catalog 6000, Section 5L. Lamp Watts 32 32 40 40 60 60 60 60 Line Voltage/Hertz 120-277/50-60 347/60 120-277/50-60 347/60 120/60 277/60 347/60 220/50 Lamp Type T8 T8 T12 T12 T12HO T12HO T12HO T12HO Hub Size 1/2 NPT 1/2 NPT 1/2 NPT 1/2 NPT 1/2 NPT 1/2 NPT 1/2 NPT 1/2 NPT FVN Fluorescent Luminaires with T5 HO Lamps (Lamps not supplied) 54 120-277/50-60 T5HO 1/2 NPT 54 347/60 T5HO 1/2 NPT 852 STIBOINFO((CRH:66008com:6L:852)) CH0 5 L - 3 0 US: 1-866-764-5454 CAN: 1-800-265-0502 2-Lamp Cat. No. FVN4232TG/UNV FVN4232TG/347 FVN4240TG/UNV FVN4240TG/347 FVN4260TG/120 FVN4260TG/277 FVN4260TG/347 FVN4260TG/200-50 3-Lamp Cat. No. FVN4332TG/UNV FVN4332TG/347 FVN4340TG/UNV FVN4340TG/347 — — — — FVN4254TG/UNV FVN4254TG/347 — — Copyright© 2006 Cooper Crouse-Hinds Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-0853-16 Name: 6L-853 100: DATE: JAN 19 2006 Time: 5:57:08 PM Operator: RB COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 CI.I, Div. 2, Groups A,B,C,D Wet Locations CI.I, Zone 2 Group IIC NEMA 3,3R CI.II, Div. 1, Groups F,G CI.III & Simultaneous Presence FVN Series Flourescent Luminaires 6L Options: The following special options are available from the factory by adding suffix to luminaire Cat. No. Description ɀ Low temperature electromagnetic ballast, 40W rated 0°F (-18°C), 60W rated -20°F (-29°C) ɀ 45° angle brackets (field installed) ɀ Adjustable angle brackets (field installed) ɀ Angle bars for chain suspension (field installed) ɀ Individually fused balast (internal) ɀ Emergency lighting battery unit (Class I, Division 2 only). Also available for use with T5 lamps Supplied with charging indicator light and instructions for use with a remote push-to-test station. † Suffix BY AG KH CX FB S799† If push-to-test operator installed in the luminaire is required, consult factory. Temperature Performance Data: (Based on 40°C ambient) Lamp 32W 40W 54W 60W Cl. I, Div. 2 & Zone 2 Supply2-Lamp 3-Lamp T5 T5 T5 T5 T3C — T4 — Class II 2-Lamp T6 T6 T6 T6 3-Lamp T6 T6 — — Simultaneous Presence 2-Lamp 3-Lamp T4 T4 T4 T4 T3C/T6 — T4 — Supply Wire 60°C 60°C 75°C 90°C Photometric Data: Luminaire with two 54W High Output T5 Linear Fluorescent Lamps FVN4254 FVN .ies photometric files for use with our Luxicon® Lighting Layout Software are available from the Resources area of our website. US: 1-866-764-5454 STIBOINFO((CRH:66008com:6L:853)) CH0 5 L - 3 0 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds 853 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-0854-3 Name: 6L-854 6L 100: DATE: JAN 19 2006 Time: 5:57:09 PM Operator: RB FVN Series Fluorescent Luminaires COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 Photometric Data Luminaire: FVN with 2-40W lamps (tempered lens) Luminaire: FVN with 3-40W lamps (tempered lens) Lamp: 2-40/T-12 Zonal Degrees: 0-30 0-40 0-60 0-90 Zonal Lumens: 1182 1971 3555 4284 Total Bare Lamp Lumens: 6300 To determine number and placement of luminaires, see Lighting Selector Guide, pages 665 to 689. Lamp: 3-40/T-12 Zonal Degrees: 0-30 0-40 0-60 0-90 Zonal Lumens: 1695 2834 5099 6079 Total Bare Lamp Lumens: 9450 To determine number and placement of luminaires, see Lighting Selector Guide, pages 665 to 689. NOTE: All data provided is for 2-lamp 40W RS cool white luminaires with tempered glass. Use 1.37 multiplier for 2-lamp 60W luminaires with tempered glass. Use .92 multiplier for 2-lamp 32W luminaires with tempered glass. Coefficient of Utilization Coefficient of Utilization Effective Floor Cavity Reflectance 20% % Reflectance Room Cavity Ratio Eff. Ceil. Wall 1 2 3 50 .721 .643 .575 80 30 .695 .603 .527 10 .673 .569 .489 50 .706 .631 .566 70 30 .683 .594 .520 10 .661 .564 .485 50 .677 .607 .547 50 30 .657 .577 .508 10 .641 .549 .476 50 .650 .586 .528 30 30 .636 .561 .496 10 .621 .538 .468 50 .627 .568 .512 10 30 .614 .544 .484 10 .602 .526 .460 0 0 .589 .512 .447 % Reflectance Room Cavity Ratio Eff. Ceil. Wall 6 7 8 50 .416 .375 .338 80 30 .359 .319 .283 10 .319 .281 .244 50 .409 .370 .333 70 30 .356 .315 .281 10 .316 .278 .244 50 .397 .359 .324 50 30 .350 .309 .277 10 .314 .276 .242 50 .386 .348 .316 30 30 .344 .306 .272 10 .311 .273 .240 50 .376 .341 .308 10 30 .338 .301 .268 10 .308 .271 .239 0 0 .295 .258 .226 Effective Floor Cavity Reflectance 20% % Reflectance Room Cavity Ratio Eff. Ceil. Wall 1 2 3 50 .682 .610 .546 80 30 .658 .572 .501 10 .637 .540 .466 50 .668 .599 .538 70 30 .646 .563 .495 10 .625 .535 .462 50 .640 .576 .520 50 30 .622 .547 .454 10 .606 .521 .433 50 .615 .556 .502 30 30 .601 .532 .472 10 .587 .511 .446 50 .594 .537 .487 10 30 .581 .517 .461 10 .570 .499 .439 0 0 .557 .487 .426 % Reflectance Room Cavity Ratio Eff. Ceil. Wall 6 7 8 50 .396 .357 .322 80 30 .343 .304 .270 10 .305 .268 .234 50 .390 .352 .317 70 30 .340 .301 .268 10 .302 .266 .233 50 .378 .342 .309 50 30 .334 .295 .264 10 .300 .264 .231 50 .368 .332 .301 30 30 .328 .292 .259 10 .298 .261 .230 50 .358 .325 .294 10 30 .322 .288 .256 10 .294 .259 .228 0 0 .283 .247 .217 854 STIBOINFO((CRH:66008com:6L:854)) CH0 0 5 L - 7 NOTE: All data provided is for 2-lamp 40W RS cool white luminaires with tempered glass. Use 1.37 multiplier for 2-lamp 60W luminaires with tempered glass. Use .92 multiplier for 2-lamp 32W luminaires with tempered glass. 4 .513 .459 .418 .505 .455 .415 .488 .444 .410 .473 .435 .405 .459 .426 .399 .385 5 .461 .404 .362 .452 .399 .359 .439 .392 .357 .426 .384 .353 .414 .378 .349 .336 9 .309 .254 .217 .305 .252 .217 .297 .249 .215 .289 .244 .214 .282 .242 .212 .200 10 .269 .215 .180 .265 .215 .180 .259 .211 .179 .253 .208 .177 .247 .205 .175 .164 US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds 4 .488 .438 .399 .480 .433 .396 .464 .423 .391 .450 .415 .386 .437 .406 .381 .368 5 .439 .385 .346 .430 .381 .343 .418 .374 .341 .406 .367 .337 .394 .361 .333 .321 9 .294 .242 .207 .290 .240 .207 .282 .237 .206 .276 .233 .204 .269 .231 .202 .192 10 .256 .205 .172 .252 .205 .172 .247 .201 .171 .241 .199 .169 .235 .196 .168 .157 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-0855-27 Name: 6L-855 100: DATE: JAN 19 2006 eLLB20 Series Recessed Mount Fluorescent Luminaires Time: 5:57:10 PM Operator: RB Class I, Div.2, Groups A,B,C,D Class I, Zone 1, Groups IIC ATEX Certified COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 Cl. II, Div 2, Groups F,G Cl. II, Div 1, Groups E,F,G (Canada) Wet Locations Enclosure Type 4X and IP66 Features & Benefits: Applications: ɀ One piece welded housing with fitted cover frame. The cover frame is an integral part of the housing to seal out dust & moisture. ɀ Adjustable mounting clamps: - permanently attached and adjustable through the cover frame for easy installation. - allow recess mounting in ceilings from 25mm to 100mm (1⍯ to 4⍯ approx) thick for maximum mounting flexibility. ɀ Support lugs (M8 x .6) to secure the luminaire to ceiling structural support members for safety. ɀ Frameless tempered glass lens: - 6mm (1⁄4⍯) thick for added safety. - interior hinge for maximum dust shedding. - fitted with captive screws for ease of lamp replacement and maintenance. ɀ Isolating switch turns off power to the ballast and lamps when the lens is opened for added safety. ɀ 4 entries (2 on each end) supplied with (2) 3⁄4” NPT adapter hubs and extra large wire well for feedthrough and tandem applications without the need for separate junction boxes. ɀ Electronic ballast: - high power factor (95%) for energy efficiency, more luminaires per circuit and supply voltage flexibility. - features 2 channel circuitry for safety - if one lamp fails the 2nd lamp remains in operation. ɀ Uses T8 linear fluorescent lamps for high efficiency and reduced operating costs. ɀ 5 wire terminal block and through wiring are standard for quick and easy balancing of lighting loads on 3 phase systems. eLLB series luminaires are used: ɀ For flush or surface ceiling mounting. ɀ In cleanroom areas where it is important to have smooth, flush surfaces. ɀ Where extreme cleanliness is required as in pharmaceutical, chemical and electronics manufacturing facilities, as well as in paint shops and spray booths. ɀ For tough environmental conditions involving corrosives, water, dust and extreme temperatures. ɀ In areas that require lamps to reach full illumination immediately. ɀ Indoor & outdoor ordinary or hazardous areas. ɀ For Wet locations and areas with hose down / wash down requirements. Adjustable Mounting Clamps Hinged Glass Lens 6L Certifications & Compliances: NEC : ɀ Class I, Division 2, Groups A,B,C,D ɀ Class I, Zone 1 AEx ed IIC ɀ Class II, Division 2, Groups F, G ɀ UL Listed CEC: ɀ Class I, Division 2, Groups A,B,C,D ɀ Class I, Zone 1 Ex eds IIC ɀ Class II, Division 1 Groups E,F,G ɀ cUL Listed Enclosure ɀ Type 4X ɀ IP66 UL Standards ɀ 2279 Hazardous (Classified) Locations ɀ 1598 Luminaires CSA Standards ɀ C22.2 No. 9 ɀ CAN/CSA-E60079-0:02 ɀ CAN/CSA-E60079-1:02 ɀ CAN/CSA-E60079-7 ɀ CAN/CSA-E61241-1-1:02 ATEX ɀ ATEX Directive 94/9/EC ɀ Type of Protection ɀ EC-Type Examination Certificate II 2 G II 2 D T80°C EEx ed IIC T4 EEx ed ib IIC T4 (CG-variant) DMT 02 ATEX E 069 Standard Materials: ɀ One piece welded housing and cover frame - sheet steel or stainless steel ɀ Lens - 6mm (1/4⍯) thick tempered glass ɀ Gaskets - Silicone ɀ External hardware - stainless steel Standard Finishes: ɀ Sheet steel - White epoxy coat ɀ Lens - Clear ɀ Stainless steel - Natural US: 1-866-764-5454 STIBOINFO((CRH:66008com:6L:855)) CH0 5 L - 3 0 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds 855 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-0856-30 Name: 6L-856 100: DATE: JAN 19 2006 COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 Class I, Div.2, Groups A,B,C,D Cl. II, Div 2, Groups F,G Class I, Zone 1, Groups IIC Cl. II, Div 1, Groups E,F,G (Canada) ATEX Certified Wet Locations Enclosure Type 4X and IP66 eLLB20 Series 6L Time: 5:57:13 PM Operator: RB Recessed Mount Fluorescent Luminaires Ratings (Electrical / Size): Temperature Performance Data: Sources/Wattages ɀ Two 32W or 17W T8 Linear Fluorescent Voltages ɀ 120-240V, 50-60 Hz. ɀ 110-230VDC Hub Size ɀ Four 25mm entries, 2 on each end, 3 plugged. ɀ Two 3⁄4” NPT adapter hubs provided standard, for feed-through or tandem wiring. Terminals ɀ 5 wire terminal block, one on each end (L1, L2, L3, N, Ground) ɀ Two 6mm2 (#10 AWG) maximum per terminal Minimum Starting Temperature: -20°C Watts Two 17W T8 lamps Two 32W T8 lamps Ambient Temp. 50°C 50°C Cl. I, Div. 2 Cl. I, Zone 1 & 2 T4 T4 Class II T6 T6 Supply Wire Temp 60°C 60°C Accessories: ɀ 3⁄4⍯ NPT adapter hub STM2 Mounting Accessories: ɀ Eye Bolt for Support Lugs ɀ Hexagon Screw for Support Lugs 2 2480 002 000 2 2480 054 000 Ordering Information: Hub Size Wattage/Lamp 3⁄4⍯ NPT Two 17 Watt T8 Rapid Start 3⁄4⍯ NPT Two 32 Watt T8 Rapid Start Voltage/Hz 120-240V, 50-60 Hz 110-230 VDC 120-240V, 50-60 Hz 110-230 VDC Operating Current Catalog Number Epoxy Coated Stainless Steel Steel Enclosure Enclosure .18A eLLB20 2217/U240 eLLB20 2217SS/U240 .34A eLLB20 4232/U240 eLLB20 4232SS/U240 IEC / CENELEC certified luminaires are available. Consult factory. Dimensions (Inches) and Weights: Item eLLB20 2217 eLLB20 4232 856 STIBOINFO((CRH:66008com:6L:856)) CH0 5 L - 3 0 US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds Weight 33 lbs. 48 lbs. Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: 100: JOB: CRMAIN06-0857-24 Name: 6L-857 DATE: JAN 19 2006 Time: 5:57:14 PM Operator: JB COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 Photometric Data eLLB20 Series Recessed Mount Fluorescent Luminaires 6L Photometric Data: COEFFICIENTS OF UTILIZATION - ZONAL CAVITY METHOD EFFECTIVE FLOOR CAVITY REFLECTANCE 20% ROOM CAVITY RATIO EFF. CEIL. 80° 70° 50° 30° 10° 0° WALL 1 2 3 4 5 6 7 8 9 10 50° 0.679 0.597 0.528 0.468 0.412 0.368 0.329 0.294 0.263 0.239 30° 0.654 0.556 0.478 0.414 0.355 0.310 0.272 0.239 0.209 0.186 10° 0.631 0.522 0.439 0.372 0.313 0.269 0.233 0.200 0.172 0.151 50° 0.664 0.585 0.518 0.459 0.405 0.632 0.324 0.290 0.259 0.235 30° 0.641 0.547 0.472 0.409 0.351 0.307 0.270 0.237 0.207 0.185 10° 0.621 0.516 0.435 0.369 0.311 0.268 0.232 0.200 0.172 0.151 50° 0.637 0.562 0.499 0.443 0.391 0.350 0.314 0.281 0.252 0.229 30° 0.618 0.531 0.460 0.399 0.344 0.302 0.265 0.233 0.204 0.182 10° 0.601 0.504 0.427 0.364 0.308 0.266 0.230 0.198 0.171 0.150 50° 0.612 0.542 0.482 0.429 0.379 0.339 0.305 0.273 0.245 0.223 30° 0.597 0.515 0.448 0.390 0.337 0.296 0.261 0.229 0.201 0.180 10° 0.583 0.492 0.420 0.360 0.304 0.263 0.228 0.197 0.170 0.149 50° 0.589 0.522 0.465 0.415 0.367 0.329 0.296 0.265 0.238 0.217 30° 0.577 0.501 0.437 0.382 0.330 0.291 0.257 0.226 0.198 0.177 10° 0.566 0.481 0.413 0.355 0.301 0.261 0.257 0.196 0.169 0.149 0° 0.553 0.468 0.400 0.341 0.288 0.248 0.214 0.183 0.156 0.137 * PERCENT REFLECTANCE US: 1-866-764-5454 STIBOINFO((CRH:66008com:6L:857)) CH0 5 L - 3 0 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds 857 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-0858-7 Name: 6L-858 6L 100: DATE: JAN 19 2006 Time: 5:57:15 PM Operator: RB COLOR: CMYK ɀ ɀ ɀ ɀ Cl. I, Div 1, Groups C,D Cl. I, Zone 1 Group IIB ɀ Cl. II, Div 1, Groups E,F,G ɀ Cl. III, Simultaneous Presence EVF Series Fluorescent Luminaires TCP: 15001 Typedriver Name: TS name csm no.: 100 Paint Spray (Suffix S718) Wet Locations (Suffix S718) ɀ 3,3R, IP54 (Suffix S718) Application: EVF luminaires are used in areas where hazardous fumes, gases, or dusts are present. EVF luminaires with S718 option are designed specifically for use inside paint spray booths where hazardous fumes, gases, and paint residue are present. This includes powder paint process areas. EVF luminaires with S718 option are also suitable for use in wet locations. Features: All EVF luminaires ɀ Provide cool, even light with natural color rendition ɀ Reduce relamping schedule (long lamp life) ɀ Continuous and uniform illumination made possible by mounting end to end (no space needed between luminaires for relamping) ɀ No special tools required for relamping. Threaded lamp tube cover provides quick and easy access for relamping ɀ Threaded joints on lamp tube and wiring chamber covers permit easy access for lower maintenance costs ɀ Reflectors can be removed or replaced with only a screwdriver ɀ Easy to install. Factory sealed and wired luminaire facilitates installation ɀ Standard electronic ballast for 32 watt and 40 watt rapid start luminaires. ɀ Standard energy efficient ballast for 40 watt slimline, 60 watt and 110 watt luminaires. ɀ Low temperature ballast is supplied as standard on 32 watt T8 (0°F), 40 watt slimline (0°F); 60 watt and 110 watt luminaires(–20°F). ɀ All exposed hardware is stainless steel for maximum protection against corrosion, and for longer luminaire life ɀ Copper-free aluminum construction throughout means lighter luminaire weight, easier installation, and excellent corrosion resistance ɀ All exterior materials are nonsparking ɀ Type P ballasts furnished in compliance with NEC ɀ Heavy-duty glass lamp tubes provide maximum strength and impact resistance to protect lamps 858 STIBOINFO((CRH:66008com:6L:858)) CH0 5 L - 2 1 3-lamp 2-lamp with angle reflector EVF Furnished For Hub Line Volts 1-Lamp 2-Lamp 3-Lamp 4-Lamp Use With Size 60 Hz.* Cat. # Cat. # Cat. # Cat. # 3⁄4⍯ 32 watt, T-8 medium 120-277 EVF21029/UNV EVF22029/UNV EVF23029/UNV EVF24029/UNV 3⁄4⍯ 347 EVF21029/347 EVF22029/347 EVF23029/347 EVF24029/347 Bi-pin 265MA lamps 40 watt, T-12 medium 3/4⍯ 110-125 EVF21082 EVF22082 EVF23082 EVF24082 Bi-pin rapid start 3/4⍯ 277 EVF21087 EVF22087 EVF23087 EVF24087 430MA lamps† 3/4⍯ 347 EVF21089/347 EVF22089/347 EVF23089/347 EVF24089/347 3⁄4⍯ 110-125 EVF21032 EVF22032 EVF23032 EVF24032 40 watt, T-12 single 3⁄4⍯ 277 EVF21037 EVF22037 EVF23037 EVF24037 pin, slimline 3⁄4⍯ 347 EVF21039/347 EVF22039/347 EVF23039/347 EVF24039/347 425MA lamps EVF21062 EVF22062 EVF23062 EVF24062 60 watt, T-12 recessed 3⁄4⍯ 110-125 EVF21067 EVF22067 EVF23067 EVF24067 contact, 800MA lamps† 3⁄4⍯ 277 3⁄4⍯ 347 EVF21069/347 EVF22069/347 EVF23069/347 EVF24069/347 EVF21072 EVF22072 EVF23072 EVF24072 110 watt, T-12 recessed 3⁄4⍯ 110-125 EVF21077 EVF22077 EVF23077 EVF24077 contact, 1500MA lamps† 3⁄4⍯ 277 3⁄4⍯ 347 EVF21079/347 EVF22079/347 EVF23079/347 EVF24079/347 * For 220 volt 50 hz, 240 volt 50 hz or 240 volt 60 hz operation change the last ‘‘2’’ in the 120 volt 60 hz catalog number to a ‘‘9’’ and add ‘‘/220 50’’, ‘‘/240 50’’ or ’’/240 60’’ respectively. ie. For a 2 lamp, 40 watt rapid start luminaire for 220 volt 50 hz operation order an EVF22089/220 50. † 50 Hz not available. EVF luminaires with S718 option ɀ All joints sealed ɀ Inside paint booth mounting capabilities provide greater flexibility in luminaire placement, avoids necessity of complicated design and installation work, and improves task lighting control ɀ Smooth simple design makes it easy to remove any accumulated deposits of paint residue Mounting Accessories: Various hazardous area fittings are used to mount EVF luminaires. The fittings shown on page 859 support the unwired (relamping) end. For the wired (ballast) end any of the luminaire hangers for hazardous locations (listed in Section 7L) can be used. CPS conduit outlet bodies with hub covers (listed in Section 4F) are also suitable Standard Materials: Options: ɀ For suitability for wet locations and locations having deposits of readily combustible paint residue – add Cat. No. Suffix S718 ɀ Corro-free TM epoxy powder coat – add Cat. No. Suffix S752 ɀ With 45° angle reflectors in lieu of straight down reflectors – add Cat. No. Suffix S369 ɀ Clear disposable polyester tube wrap – consult Cooper Crouse-Hinds ɀ Fused – add suffix S658‡ ɀ Furnished with lamps - add suffix S714. ɀ Low temperature electromagnetic ballast for 40 watt T12 rapid start luminaires rated for 0°F - add suffix BY. Size Ranges: ɀ 1, 2, 3, and 4-lamp Electrical Rating Ranges: ɀ Copper-free aluminum except sheet aluminum reflectors Standard Finishes: ɀ Natural except reflectors ɀ Reflectors – white epoxy powder coat Certifications and Compliances: ɀ NEC and CEC: Class I, Division 1 Group C, D Class I, Zone 1 Group IIB Class II Group E, F, G Class III Simultaneous Presence (Cl. I and Cl. II) Paint Spray (S718) ɀ UL Standards: 844 Hazardous (Classified) Locations 1598 Luminaires ɀ CSA Standards: C22.2 No. 137 ɀ 32 to 110 watts Temperature Performance Data: (Based on 40°C Ambient) Lamp Type 32/40W 60W 110W 1 Lamp T5 T5 T4 US: 1-866-764-5454 Class I/Class II/Zone 1 2 Lamp 3 Lamp 4 Lamp T5 T5 T5 T5 T5 T5 T4 T4 T4 CAN: 1-800-265-0502 Supply Wire 75°C 75°C 90°C Copyright© 2006 Cooper Crouse-Hinds ‡ When ordering fuses for luminaires, option S658, you must specify the operating voltage. S658 cannot be ordered with /MT in the catalog number. Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-0859-2 Name: 6L-859 100: DATE: JAN 19 2006 Time: 5:57:17 PM Operator: TB Size 3⁄4 TCP: 15001 Typedriver Name: TS name csm no.: 100 Accessories Relamping Information EVF Series Fluorescent Luminaires Ceiling Saddle for Conduit Support COLOR: CMYK 6L Relamping Information Cat. # EVF20 Ceiling Saddle for Support Hook Adjacent ends of two fixtures suspended in line close together Cat. # EVF021 One cover removed and lamp partly withdrawn Where fixtures abut, space for relamping is obtained by lowering one end of the tube assembly as shown. Without tools, the lamp receptacle and mounting plate assemblies can be removed and the lamp withdrawn. In inserting, the reverse procedure is followed. Support Hook for Conduit Size 3⁄4 Cat. # EVF21 End of one fixture lowered for relamping Dimensions End view Fixture Type 32 watt, T-8 Bi-pin 40 watt, T-12 Bi-pin 40 watt, T-12 Single pin slimline 60 watt, T-12 Recessed contact 110 watt, T-12 Recessed contact No. Lamps ⎫ ⎭ 1 or 2 3 or 4 US: 1-866-764-5454 STIBOINFO((CRH:66008com:6L:859)) CH0 5 L - 2 2 a 44 461⁄2 b 11 81⁄2 c d 533⁄8 533⁄8 CAN: 1-800-265-0502 55 55 e 95 100 f 101⁄4 101⁄4 Copyright© 2006 Cooper Crouse-Hinds 1-Lamp 2-Lamp 3-Lamp 4-Lamp Width 61⁄8 111⁄2 18 241⁄2 859 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: JOB: CRMAIN06-0860-3 Name: 6L-860 6L 100: DATE: JAN 19 2006 Time: 5:57:18 PM Operator: RB EVF Series Fluorescent Luminaires COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 Photometric Data Luminaire: All 1-Lamp EVF Luminaires Luminaire: All 2-Lamp EVF Luminaires Lamp: 1-40/T-12, 1-60/T-12 Zonal Degrees: 0-30 0-40 0-60 0-90 Zonal Lumens: 580 953 1633 1897 Total Bare Lamp Lumens: 3100 To determine number and placement of luminaires, see Lighting Selector Guide, pages 665 to 689. Lamp: 2-40/T-12, 2-38/T-12, 2-60/T-12, 2-110/T12 Zonal Degrees: 0-30 0-40 0-60 0-90 Zonal Lumens: 1055 1765 3262 4125 Total Bare Lamp Lumens: 6300 To determine number and placement of luminaires, see Lighting Selector Guide, pages 665 to 689. NOTE: All data provided is for 40W rapid start cool white lamps. Use following candlepower/lumen multipliers for other lamp sizes: 32W 0.90 40W Slimline 0.84 60W Cool white 1.29 110W Cool white 2.19 NOTE: All data provided is for 40W rapid start cool white lamps. Use following candlepower/lumen multipliers for other lamp sizes: 32W 0.90 40W Slimline 0.84 60W Cool white 1.29 110W Cool white 2.19 Example: Zonal lumens of 1-40W lamp for 0-60° is 1633. Zonal lumens of 1-60W lamp for 0-60° is 1633 × 1.29 ⍧ 2107 Example: Zonal lumens of 2-40W lamp for 0-60° is 3262. Zonal lumens of 2-60W lamps for 0-60° is 3262 × 1.29 ⍧ 4208 Coefficient of Utilization Coefficient of Utilization Effective Floor Cavity Reflectance 20% % Reflectance Room Cavity Ratio Eff. Ceil. Wall 1 2 3 50 .697 .616 .546 80 30 .670 .574 .497 10 .647 .539 .458 50 .682 .604 .538 70 30 .658 .565 .490 10 .635 .534 .454 50 .653 .580 .518 50 30 .633 .549 .478 10 .616 .520 .446 50 .627 .559 .500 30 30 .612 .533 .467 10 .597 .509 .438 50 .605 .539 .484 10 30 .591 .517 .455 10 .579 .498 .431 % Reflectance Room Cavity Ratio Eff. Ceil. Wall 6 7 8 50 .391 .351 .316 80 30 .334 .295 .262 10 .294 .257 .223 50 .384 .346 .312 70 30 .330 .292 .260 10 .290 .255 .222 50 .372 .336 .303 50 30 .324 .286 .255 10 .288 .252 .221 50 .361 .325 .295 30 30 .319 .283 .251 10 .286 .249 .219 50 .351 .318 .287 10 30 .312 .278 .247 10 .283 .248 .218 Effective Floor Cavity Reflectance 20% % Reflectance Room Cavity Ratio Eff. Ceil. Wall 1 2 3 50 .697 .616 .546 80 30 .670 .574 .497 10 .647 .539 .458 50 .682 .604 .538 70 30 .658 .565 .490 10 .635 .534 .454 50 .653 .580 .518 50 30 .633 .549 .478 10 .616 .520 .446 50 .627 .559 .500 30 30 .612 .533 .467 10 .597 .509 .438 50 .605 .539 .484 10 30 .591 .517 .455 10 .579 .498 .431 % Reflectance Room Cavity Ratio Eff. Ceil. Wall 6 7 8 50 .391 .351 .316 80 30 .334 .295 .262 10 .294 .257 .223 50 .384 .346 .312 70 30 .330 .292 .260 10 .290 .255 .222 50 .372 .336 .303 50 30 .324 .286 .255 10 .288 .252 .221 50 .361 .325 .295 30 30 .319 .283 .251 10 .286 .249 .219 50 .351 .318 .287 10 30 .312 .278 .247 10 .283 .248 .218 860 STIBOINFO((CRH:66008com:6L:860)) CH0 5 L - 2 3 98: 4 .485 .430 .388 .477 .426 .385 .460 .416 .380 .445 .407 .375 .431 .397 .370 5 .434 .376 .334 .425 .372 .331 .412 .365 .329 .399 .357 .325 .388 .351 .321 9 .289 .235 .197 .285 .233 .197 .277 .229 .196 .270 .225 .194 .263 .222 .193 10 .252 .198 .164 .248 .198 .164 .242 .195 .162 .236 .192 .161 .230 .189 .159 US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds 4 .485 .430 .388 .477 .426 .385 .460 .416 .380 .445 .407 .375 .431 .397 .370 5 .434 .376 .334 .425 .372 .331 .412 .365 .329 .399 .357 .325 .388 .351 .321 9 .289 .235 .197 .285 .233 .197 .277 .229 .196 .270 .225 .194 .263 .222 .193 10 .252 .198 .164 .248 .198 .164 .242 .195 .162 .236 .192 .161 .230 .189 .159 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-0861-3 Name: 6L-861 100: DATE: JAN 19 2006 Time: 5:57:19 PM Operator: RB TCP: 15001 Typedriver Name: TS name csm no.: 100 Photometric Data EVF Series Fluorescent Luminaires 6L Luminaire: All 3-Lamp EVF Luminaires Luminaire: All 4-Lamp EVF Luminaires Lamp: 3-40/T-12, 3-38/T-12, 3-60/T-12, 3-110/T-12 Zonal Degrees: 0-30 0-40 0-60 0-90 Zonal Lumens: 1917 3226 6066 7919 Total Bare Lamp Lumens: 9300 To determine number and placement of luminaires, see Lighting Selector Guide, pages 665 to 689. Lamp: 4-40/T-12, 4-38/T-12, 4-60/T-12, 4-110/T-12 Zonal Degrees: 0-30 0-40 0-60 0-90 Zonal Lumens: 1961 3305 6250 8224 Total Bare Lamp Lumens: 12400 To determine number and placement of luminaires, see Lighting Selector Guide, pages 665 to 689. NOTE: All data provided is for 40W rapid start cool white lamps. Use following candlepower/lumen multipliers for other lamp sizes: 32W 0.90 40W Slimline 0.84 60W Cool white 1.29 110W Cool white 2.19 NOTE: All data provided is for 40W rapid start cool white lamps. Use following candlepower/lumen multipliers for other lamp sizes: 32W 0.90 40W Slimline 0.84 60W Cool white 1.29 110W Cool white 2.19 Example: Zonal lumens of 3-40W lamps for 0-40° is 3226. Zonal lumens of 3-40W Slimline lamps for 0-40° is 3226 × 0.84 ⍧ 2710 Example: Zonal lumens of 4-40W lamps for 0-30° is 1961. Zonal lumens of 4-110W lamps for 0-30° is 1961 × 2.19 ⍧ 4295 Coefficient of Utilization Coefficient of Utilization Effective Floor Cavity Reflectance 20% % Reflectance Room Cavity Ratio Eff. Ceil. Wall 1 2 3 50 .712 .626 .553 80 30 .683 .581 .500 10 .658 .544 .459 50 .697 .614 .544 70 30 .670 .572 .494 10 .646 .539 .455 50 .667 .589 .524 50 30 .645 .555 .481 10 .626 .524 .446 50 .640 .567 .505 30 30 .623 .539 .469 10 .607 .513 .439 50 .617 .547 .488 10 30 .602 .523 .457 10 .589 .502 .431 % Reflectance Room Cavity Ratio Eff. Ceil. Wall 6 7 8 50 .392 .352 .317 80 30 .332 .293 .260 10 .290 .254 .219 50 .385 .347 .312 70 30 .329 .290 .258 10 .287 .251 .218 50 .372 .336 .303 50 30 .322 .284 .253 10 .285 .248 .217 50 .362 .325 .295 30 30 .317 .280 .248 10 .282 .245 .215 50 .351 .317 .286 10 30 .310 .276 .244 10 .279 .244 .214 Effective Floor Cavity Reflectance 20% % Reflectance Room Cavity Ratio Eff. Ceil. Wall 1 2 3 50 .692 .607 .535 80 30 .664 .563 .484 10 .639 .526 .442 50 .678 .595 .526 70 30 .652 .554 .477 10 .628 .521 .439 50 .648 .571 .507 50 30 .627 .538 .465 10 .609 .507 .431 50 .622 .550 .488 30 30 .606 .522 .453 10 .590 .497 .423 50 .600 .530 .472 10 30 .585 .506 .442 10 .572 .486 .416 % Reflectance Room Cavity Ratio Eff. Ceil. Wall 6 7 8 50 .379 .340 .306 80 30 .320 .282 .250 10 .278 .243 .210 50 .372 .335 .301 70 30 .316 .279 .248 10 .275 .240 .209 50 .359 .324 .292 50 30 .310 .273 .243 10 .273 .238 .208 50 .349 .313 .284 30 30 .305 .269 .238 10 .271 .235 .206 50 .339 .306 .276 10 30 .298 .265 .235 10 .268 .234 .205 4 .489 .431 .386 .481 .426 .383 .463 .416 .378 .447 .407 .374 .433 .397 .368 5 .436 .376 .331 .427 .371 .328 .414 .364 .326 .400 .356 .322 .388 .350 .318 9 .289 .233 .194 .285 .230 .194 .277 .227 .192 .269 .223 .191 .262 .220 .189 10 .252 .196 .160 .248 .196 .160 .242 .193 .159 .236 .190 .157 .230 .187 .156 US: 1-866-764-5454 STIBOINFO((CRH:66008com:6L:861)) CH0 5 L - 2 4 COLOR: CMYK CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds 4 .473 .416 .372 .465 .411 .369 .447 .401 .364 .432 .392 .360 .418 .383 .354 5 .421 .362 .318 .412 .357 .315 .399 .351 .313 .386 .343 .309 .374 .337 .305 9 .279 .224 .185 .275 .221 .185 .267 .218 .184 .260 .214 .183 .253 .211 .181 10 .243 .189 .153 .239 .189 .153 .233 .185 .152 .227 .182 .150 .221 .179 .149 861 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-0862-5 Name: 6L-862 6L 100: DATE: JAN 19 2006 Time: 5:57:20 PM Operator: RB COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 ɀ ɀ Marine & Wet Cl. I, Div. 1, Groups C,D Cl. I, Zone 1 Group IIB Locations ɀ Cl. II, Div 1, Groups E,F,G ɀ 3,3R,4,4X: IP66 ɀ Cl. III, Simultaneous Presence EVFDR Series Fluorescent Luminaires ɀ Applications: ɀ EVFDR luminaires are suitable for wet locations and marine environments, above and below deck, where hazardous vapors, gases or dusts are present ɀ Ideally suited for use on offshore drilling/ production platforms and on shipboard in hazardous areas ɀ For mounting where headroom is limited ɀ For hazardous areas where watertightness and corrosion resistance are required Features: ɀ Exterior surfaces finished with gray epoxy enamel for corrosion resistance ɀ Exterior hardware stainless steel ɀ All joints sealed and gasketed for watertightness ɀ Vibration resistant -shock mounts -sockets are spring loaded for tight lamp contact connection ɀ Heavy duty glass lamp tubes for maximum strength and impact resistance ɀ All exterior materials are non-sparking ɀ C-type beam clamps provide quick and easy mounting ɀ Luminaire is adjustable 30° either side of fixture axis, allowing for control of light output ɀ Beam clamp support is adjustable allowing beam clamp to be located to suit structure ɀ Low profile – luminaire height is 713⁄16⍯ with standard mounting, 1111⁄16⍯ with shock mounting option – for maximum clearance where headroom is critical ɀ Provides cool light with natural color rendition ɀ Continuous and uniform illumination made possible by mounting end to end (no space needed between luminaires for relamping) – see page 859 for relamping information ɀ Relamping is accomplished without tools. Quarter-turn fastener allows end of luminaire to be lowered quickly. Cable supports end of luminaire while relamping – both hands are free. Threaded lamp tube cover provides quick and easy access to lamp and receptacle ɀ Reflectors can be removed or replaced with only a screwdriver ɀ Ballast housing readily accessible ɀ Minimum weight – copper-free aluminum construction throughout ɀ Type P ballast furnished in compliance with NEC ɀ Standard electronic ballast for 32 watt and 40 watt rapid start. ɀ Standard energy efficient electromagnetic ballast (40W slimline, 60W and 110W) is standard. ɀ Low temperature ballasts are standard on 32WT8, 40W slimline, 60W and 110W. 32 watt and 40 watt low temperature ballasts are rated for 0°F. 60 and 100 watt low temperature ballasts are rated for –20°F. Standard Materials: ɀ Housing – copper-free aluminum ɀ Exposed hardware – stainless steel 862 STIBOINFO((CRH:66008com:6L:862)) CH0 5 L - 2 5 Options: ɀ Furnished with lamps – add suffix S714 to Cat. No. ɀ Furnished with safety cable for high vibration areas - add suffix S715 to Cat. No. ɀ Beam clamps with shock mounts are available for ease of installation and resistance to vibration – add suffix KIT40 to Cat. No. ɀ Beam clamps only – add suffix KIT41 to Cat. No. ɀ Low Temperature Electromagnetic Ballast: 40W rapid start rated 0°F - add suffix BY to Cat. No. ɀ Emergency lighting battery unit – add suffix S799 to Cat. No. Size Ranges: Certifications and Compliances: ɀ NEC and CEC: Class I, Division 1 Group C,D Class I, Zone 1 Group IIB Class II Groups E,F,G Class III Simultaneous Presence (Cl. and Cl. II) ɀ UL Standards 844 Hazardous (Classified) Locations 1598 Luminaires 1598A Marine Locations ɀ CSA Standards C22.2 No. 137 Temperature Performance Data: (Based on 40°C Ambient) ɀ 2-lamp only Electrical Rating Ranges: ɀ 32, 40, 60 and 110W 2-Lamp 32, 40W 60W 110W Class I Class II Zone 1 T5 T5 T4 Supply Wire 75°C 75°C 90°C EVFDR Furnished For Use With 32 watt, T-8 medium Bi-pin 265MA lamps 40 watt, T-12 medium Bi-pin rapid start 430MA lamps† 60 watt, T-12 recessed contact, 800MA lamps 110 watt, T-12 recessed contact, 1500MA lamps† Hub Size 3⁄4⍯ 3⁄4⍯ 3/4⍯ 3/4 3/4⍯ 3/4⍯ 3/4⍯ 3/4⍯ Line Volts 60 Hz.* 120-277 347 110-125 277 2-Lamp Cat. # EVFDR22029/UNV EVFDR22029/347 EVFDR22082 EVFDR22087 110-125 277 110-125 277 EVFDR22062 EVFDR22067 EVFDR22072 EVFDR22077 * For 220 volt 50 hz, 240 volt 50 hz or 240 volt 60 hz operation change the last ‘‘2’’ in the 120 volt 60 hz catalog number to a ‘‘9’’ and add ‘‘/220 50’’, ‘‘/240 50’’ or ‘‘/240 60’’ respectively. ie. For a 2 lamp, 40 watt rapid start fixture for 220 volt 50 hz operation order an EVFDR22089/220 50. † 50 Hz. not available. Standard Finishes: ɀ All exterior metal components – gray epoxy enamel ɀ Reflectors – white epoxy powder coat US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-0863-3 Name: 6L-863 100: DATE: JAN 19 2006 Time: 5:57:21 PM Operator: RB COLOR: CMYK TCP: 15001 Photometric Data and Dimensions EVFDR Series Fluorescent Luminaires Typedriver Name: TS name csm no.: 100 6L Dimensions Luminaire: All EVFDR Luminaires Lamp: 2-40/T-12, 2-60/T-12, 2-110/T-12 Zonal Degrees: 0-30 0-40 0-60 0-90 Zonal Lumens: 1416 2352 4263 5863 Total Bare Lamp Lumens: 8600 To determine number and placement of luminaires, see Lighting Selector Guide, pages 665 to 689. NOTE: All data provided is for two 60 watt, T-12 recessed contact 800MA cool white lamps (EVFDR22062). For other wattages use the following conversion factors: 32W .67 40W, Rapid Start .73 40W, Slimline .70 110W, Cool White 1.60 Coefficient of Utilization Example: Zonal lumens for EVFDR226 fixture, across the axis, for 40-50° is 1,060. Zonal lumens for EVFDR223 fixture, across the axis, is 40-50° is: 1,060 × .70 ⍧ 742 Effective Floor Cavity Reflectance 20% % Reflectance Room Cavity Ratio Eff. Ceil. Wall 1 2 3 50 .735 .645 .570 80 30 .700 .594 .512 10 .670 .551 .466 50 .714 .627 .557 70 30 .682 .580 .501 10 .653 .542 .458 50 .673 .593 .528 50 30 .647 .554 .482 10 .624 .520 .444 50 .636 .562 .501 30 30 .616 .530 .463 10 .596 .502 .430 50 .603 .533 .477 10 30 .585 .507 .444 10 .570 .483 .416 0 0 .551 .465 .399 % Reflectance Room Cavity Ratio Eff. Ceil. Wall 6 7 8 50 .408 .368 .332 80 30 .344 .305 .271 10 .298 .262 .228 50 .398 .360 .325 70 30 .338 .299 .267 10 .293 .258 .226 50 .380 .344 .311 50 30 .327 .289 .259 10 .287 .252 .221 50 .364 .328 .299 30 30 .317 .282 .251 10 .281 .246 .217 50 .348 .316 .286 10 30 .306 .274 .244 10 .274 .241 .213 0 0 .259 .226 .198 4 .506 .442 .394 .494 .435 .388 .468 .418 .378 .446 .403 .368 .425 .388 .358 .340 5 .452 .387 .339 .440 .380 .334 .420 .368 .327 .401 .354 .319 .383 .343 .311 .294 9 .304 .243 .202 .297 .240 .201 .285 .233 .197 .274 .226 .193 .263 .220 .189 .175 10 .266 .207 .169 .260 .206 .168 .250 .199 .164 .240 .193 .160 .231 .188 .157 .144 US: 1-866-764-5454 STIBOINFO((CRH:66008com:6L:863)) CH0 5 L - 2 6 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds 863 Zoom: 100