9. Verifying RF Output 10. Verifying Audio and Video on a DHCT To verify that you have established the correct RF output for the RF OUT port, follow these steps. After sessions are defined on the DNCS, verify that audio and video are performing properly on a local Digital Home Communications Terminal (DHCT). a. Connect an RF OUT port on the modulator to a spectrum analyzer. Quick Reference Guide b. Verify the output level for the frequency and the channel using a spectrum analyzer. c. Repeat steps a and b for the remaining RF OUT port connections. Dual SFP Gigabit QAM Modulator Dual SFP GQAM Front Panel Use the following diagram to assist you with the installation of the modulator. Note: The front panel is identical for both the AC and DC dual SFP GQAM models. MAJOR ALARM MINOR ALARM FREQ LEVEL CW OPTIONS ENTER RF SEL CW MAJOR ALARM MINOR ALARM GQAM Modulator Model D9479-12 AC DUAL SFP FREQ LEVEL CW OPTIONS ENTER RF SEL CW T12555 GQAM Modulator Model D9479-12 AC DUAL SFP Dual SFP GQAM Back Panels Use the following diagrams to assist you with the installation of the modulator, as well as the location of the connection ports. D9479-12 120/230V AC DUAL SFP MAIN ASI IN 1 ASI IN 2 ASI IN 3 ASI IN 4 DATA 4 GIGABIT ETHERNET BACKUP CRAFT PORT DATA 4 RF OUT 4 DATA 3 RF OUT 3 DATA 2 RF OUT 2 DATA 1 RF OUT 1 LINK 120/130V 60/50Hz 2.5A LINK POWER CRAFT PORT 10/100 BASE T LINK ACTIVE GND 10/100 BASE T LINK ACTIVE GND -V T4H, 250V ACT -A ACT T D9479-22 48V DC DUAL SFP CONTINUED PROTECTION AGAINST FIRE CAUTION: FOR REPLACE ONLY WITH SAME TYPE 5.0 A SLO BLO 250 V FUSE ASI IN 1 ASI IN 2 ASI IN 3 ASI IN 4 DATA 3 MAIN DATA 2 GIGABIT ETHERNET BACKUP DATA 1 RF OUT 4 LINK RF OUT 3 ACT RF OUT 2 LINK -48 VDC 160w RF OUT 1 FUSE ACT 48 VOLTS DC FUSE T12556 Rack Mount Brackets Use the following diagram to assist you with the installation of the modulator using the supplied notched rack mount brackets. CAUTION: Take care to install the notched rack mount brackets as shown in the following picture. Inverting the brackets will block airflow, which will cause the unit to overheat and damage the unit. &LVFR6\VWHPV,QF 5030 Sugarloaf Parkway, Box 465447 Lawrenceville, GA 30042 678.277.1 www.FLVFR.com Cisco and the Cisco Systems logo are registered trademarks or trademarks of Cisco and/or its affiliates in the U.S. and certain other countries. Third party trademarks mentioned are the property of their respective owners. Product and service availability subject to change without notice. T13737 © 2006-2008, 2012 Cisco Systems, Inc. All rights reserved. September 2012 Printed in USA Part Number 78-4002206-01Rev D Introduction Using an Equipment Rack Adjacent to a Wall This rack installation quick reference is intended for individuals who are responsible for installing the dual small form-factor pluggable (SFP) gigabit quadrature amplitude modulation (GQAM) modulator into a rack system. Make sure you have sufficient exhaust on one side of each modulator if it is installed in a rack adjacent to a wall. If there is not sufficient airflow through the rack, the heated exhaust air may recirculate to the input side of the modulator and produce inlet air temperatures above the 122oF (50oC) maximum. For detailed descriptions of the installation process and safety information for this modulator, refer to the Dual SFP GQAM Modulator Installation and Operation Guide, (part number 4014102). Warning and Caution Icons WARNING: Avoid personal injury and product damage! Do not proceed beyond any icon until you fully understand the indicated conditions. The following icons alert you to important information about the safe operation of this product. Measuring the Inlet Air Temperature Important: You must use the supplied notched rack mount brackets to provide additional support and to allow correct air circulation through the unit. Using standard L brackets will restrict airflow and cause the modulator to overheat. Important: Opening the door on the back panel of the rack can have an adverse effect on the managed airflow. If access to the door is not controlled, measure the inlet air temperature with the back panel door open because this typically redirects the airflow in an adverse manner. Complete these steps to install the dual SFP GQAM into the rack. Sample Rack Configurations This section provides two fully loaded and recommended rack configurations for setting up your dual SFP GQAM. They include the following configurations: You may find this icon affixed to this product and in this document to alert you of electrical safety hazards. On this product, this icon indicates a live terminal; the arrowhead points to the terminal device. • Rack with a top-mounted exhaust fan—Includes a 40 rack unit (RU) configuration with up to 32 modulators. The remaining 8 RUs are configured with 4 vacant RUs at the top and 4 vacant RUs at the bottom of the rack. You may find this icon affixed to this product. This icon indicates a protective earth terminal. The 4 RU space at the top of the rack is covered with closed panels and uses an exhaust fan (top of rack) to draw the heated air upward and out of the rack. This 4 RU space also allows the ventilation space for the exhaust fan to operate efficiently. Important: In order for the fans to operate correctly, you must install each modulator using the rack mount brackets included with the unit. These brackets contain notched cutout sections to allow for clearance so that air can enter and exit the unit without restriction. Install dual SFP GQAMs directly above or below each other with no requirements for vented spacers when you use the rack mounts provided. Controlling the Operating Temperature CAUTION: Cisco headend equipment is designed to operate in a maximum 122oF (50oC) environment. Specifically, this means that the air temperature at the air inlet of any modulator must never exceed 122oF (50oC). When you are determining heating, ventilation, and air conditioning (HVAC) calculations, each modulator draws 151 W of input power (515 BTU/hr). Example: A full rack system (32 modulators) totals 4832 W (16,480 BTU/hr) of input power. Using Side-by-Side Equipment Racks Side-by-side equipment racks often do not include an internal wall between them. Therefore, take extreme caution if you are installing modulators in these types of rack systems. Because there is an 18oF (10oC) rise from the inlet air temperature to the exhaust air temperature on a modulator, a cumulative effect on the temperature may result from one rack to an adjacent rack. Remember, you cannot exceed the 122oF (50oC) maximum inlet air temperature. CAUTION: Do not tangle or strain interconnecting cables. Use caution when installing wiring and racks to avoid obstruction of airflow into the side air vents of the dual SFP GQAM or out of the vent fans on the side. If you are concerned about the inlet air temperature at the air inlet of any modulator, you can measure the inlet air temperature in the rack. When measuring the temperature, ensure that all cabling is complete and that all adjacent dual SFP GQAMs are installed and running. You will find this icon in the literature that accompanies this product. This icon indicates important operating or maintenance instructions. Stacking Guidelines 1. Installing the Dual SFP GQAM into a Rack Note: Use an exhaust fan that allows air, at a minimum of 600 cubic feet per minute (cfm), to flow through the rack (2000 cfm is the ideal rate). The 4 RU space at the bottom of the rack is vented on the front and back of the rack. The vents allow air to freely enter the rack and cool the dual SFP GQAMs. • Rack with floor plenum forced air cooling—Includes a 40 RU configuration with up to 32 dual SFP GQAMs. The remaining 8 RUs are configured with 4 vacant RUs at the top and 4 vacant RUs at the bottom of the rack. The lower 4 RU spaces are covered with solid panels and the upper 4 RU spaces are vented along with the entire top of the rack. The floor plenum forced airflow must allow air, at a minimum of 600 cfm, to flow through the rack (2000 cfm is the ideal rate). Installation and Connections Complete steps 1 through 10 to install and connect the modulator into the rack unit. Important: Refer to the back page of this quick reference guide to view the front and back panels of dual SFP GQAM models, as well as the connection ports. WARNING: To avoid electrical shock, perform only the instructions that are included in steps 1 through 10. Refer all servicing to authorized service personnel. a. Unpack and inspect the modulator. c. Connect the other end of the power cord to an AC electrical outlet. d. Keep the power source set to the OFF position until you are ready to power on the modulator. 3. Connecting DVB ASI Input Ports Follow these steps to connect the DVB ASI input ports on the rear panel of the modulator to the video distribution plant. a. Locate the RG6 cable attached to the DVB ASI source. b. Attach the other end of this cable to one of four DVB ASI IN ports on the rear panel of the modulator. 4. Connecting the 10/100BaseT Ethernet Port b. Record the MAC address from the label on the underside of the modulator chassis. Follow these steps to set up an Ethernet connection and enable the DNCS to perform system management and diagnostics. Control MAC Address: _________________________________ a. Connect one end of a screened or shielded CAT-5 cable with an RJ45 connector to the rear panel of the modulator. GigE 0 MAC Address: _________________________________ b. Connect the other end of this cable to the Ethernet hub. GigE 1 MAC Address: _________________________________ c. Install the supplied rack mounts. Important: The supplied notched rack mount brackets (part numbers 734845 and 734846) must be used. When you use the supplied notched rack mount brackets, you can install the modulator above or below each other in the rack with no space required. 5. Connecting to the Gigabit Ethernet Ports Follow these steps to connect a data sharing device (for example, the DNCS or a video-on-demand [VOD] server) to one of the gigabit Ethernet (GbE) ports on the modulator. d. Place the modulator in the rack. a. Insert an SFP module into the main GbE port on the back of the modulator. e. Insert a mounting screw through each of the four bezel mounting holes on the front panel of the modulator and also into the rack. b. Depending on the type of SFP you are using, connect the data sharing device to the GQAM using one of the following methods: f. Firmly tighten each mounting screw. • Use two single-mode or multimode fiber cables with a type SC connector (one for input and one to output data) 2. Connecting the Power Sources • Use 8-conductor CAT-5 Ethernet 10/1000BaseT wiring with RJ-45 connectors Follow these steps to connect an earth ground and either a DC or an AC power source to the dual SFP GQAM. Connecting an Earth Ground WARNING: The 48 V DC dual SFP GQAM must be connected to an earth ground. a. Place a ground wire onto the ground lug (labeled GND) on the back of the modulator. b. Tighten the ground lug to secure the ground wire. c. Connect the other end of the ground wire to the rack or to an earth ground. Connecting a DC Power Source Only a. Verify that the DC power source is set to the OFF position. b. Insert the wires from the DC power source into the terminal block connector. c. Use a small flat-blade screwdriver to tighten the screws at the top of the terminal block connector to secure the wires. d. Insert the terminal block connector into the terminal block on the back panel of the 48 V DC modulator. e. Keep the DC power source set to the OFF position until you are ready to power on the modulator. Note: You will need to place a ferrite bead in series with the power source to reduce high frequency noise. Note: If a redundant gigabit input is required, repeat steps a and b for the backup gigabit Ethernet port. If the dual gigabit configuration is being used, the ASI input ports are not supported. 6. Provisioning the Modulator on the DNCS To provision the GQAM modulator as a Digital Broadband Delivery System (DBDS) element on the Digital Network Control System (DNCS), refer to the Gigabit QAM Modulator Model D9479 Installation and Operation Guide, (part number 745431). 7. Powering On the Modulator Follow these steps to power on the dual SFP GQAM. a. Place the power switch on the modulator in the ON position. b. Verify that the modulator boots. 8. Connecting RF Out Ports CAUTION: Turning on the dual SFP GQAM with the default RF output level may cause RF interference with the services of other units connected to the network. Therefore, set the RF output level before you connect any RF OUT ports to the network or distribution plant. Connecting an AC Power Source Only Follow these steps to connect the RF out ports on the rear panel of the modulator to the distribution plant (combiner). a. Verify that the power switch on the back of the modulator is placed in the OFF position. a. Connect one end of a 75-ohm coaxial cable to each RF OUT port on the modulator, as needed. b. Connect the power cord to the AC power inlet on the back panel of the 120/230 V AC modulator. b. Connect the other end of each cable to the distribution plant (combiner).