The Carter Sullivan MCB/MCCB range of bypass switch has been designed for applications where local fault protection is required. Full key operated UPS interlocking can be added to MCB/MCCB range. The switches allow the user to bypass, test and even remove UPS from circuit without disruption to the supported load. The Carter Sullivan design features ensure the installer, commissioning engineer and end user can have complete control over the installed system. The MCB/MCCB range of switches can also be fitted with UPS interlocking. Interlocking can ensure the Manual Bypass breaker can only be operated if the UPS are in static bypass mode. MCB/MCCB EXTERNAL MAINTENANCE BYPASS SWITCHES SINGLE UPS SOLUTIONS PRODUCT INFO VOLTAGE 230V or 400V RATING 32A - 630A ENCLOSURE Floor & Wall mounted steel FEATURES Switches designed and engineered specifically for UPS applications. - Individual UPS input/output breakers The ability to add UPS interlocking Volt free contacts The ablity to add plain or glazed doors Trafolyte labelling Fault protection MCB/MCCB EMBS SPECIFICATIONS THE CARTER SULLIVAN MCB/MCCB RANGE OF EMBS IS AVAILABLE IN BOTH 230V & 400V FORMATS AND CURRENT RATINGS FROM 32A TO 630A+. SINGLE UPS SOLUTIONS UPS FORMAT OUTPUT PHASES SWITCH TYPE UPS INPUT RATING M/BYPASS kVA* RATING 1:1 230V MCB 32A 32A 6 330 x 600 x 210 1C-MCB-11-32-32 1:1 230V MCB 40A 40A 8 330 x 600 x 210 1C-MCB-11-40-40 1:1 230V MCB 50A 50A 10 330 x 600 x 210 1C-MCB-11-50-50 1:1 230V MCB 63A 63A 11 330 x 600 x210 1C-MCB-11-63-63 1:1 230V MCB 80A 80A 15 480 x 600 x210 1C-MCB-11-80-80 1:1 230V MCB 100A 100A 20 480 x 600 x 210 1C-MCB-11-100-100 3:1 400/230V MCB 40A 40A 8 330 x 600 x 210 1C-MCB-31-40-40 3:1 400/230V MCB 50A 50A 10 480 x 600 x 210 1C-MCB-31-50-50 3:1 400/230V MCB 80A 80A 15 480 x 600 x 210 1C-MCB-31-80-80 3:1 400/230V MCB 100A 100A 20 480 x 600 x 210 1C-MCB-31-100-100 3:1 400/230V MCCB 160A 160A 30 780 x 600 x 210 1C-MCCB-33-160-160 3:3 400V MCB 32A 32A 15 480 x 600 x 210 1C-MCB-33-32-32 3:3 400V MCB 40A 40A 20 480 x 600 x 210 1C-MCB-33-40-40 3:3 400V MCB 63A 63A 30 480 x 600 x 210 1C-MCB-33-63-63 3:3 400V MCB 80A 80A 40 480 x 900 x 210 1C-MCB-33-80-80 3:3 400V MCB 100A 100A 50 480 x 1200 x 210 1C-MCB-33-100-100 3:3 400V MCB 125A 125A 60 480 x 1200 x 210 1C-MCB-33-125-125 3:3 400V MCCB 160A 160A 100 780 x 1200 x 210 1C-MCCB-33-160-160 3:3 400V MCCB 200A 200A 120 930 x 1200 x 210 1C-MCCB-33-200-200 3:3 400V MCCB 250A 250A 160 930 x 1200 x 210 1C-MCCB-33-250-250 3:3 400V MCCB 320A 320A 200 1530 x 1200 x 210** 1C-MCCB-33-320-320 3:3 400V MCCB 400A 400A 250 1530 x 1200 x 210** 1C-MCCB-33-400-400 3:3 400V MCCB 630A 630A 400 1830 x 1200 x 210** 1C-MCCB-33-630-630 1 STATION COURT SHARNBROOK BEDFORD BEDFORDSHIRE MK44 1PU T +44 (0)1234 781500 F +44 (0)1234 782758 E enquiry@cartersullivan.co.uk www.catersullivan.co.uk *The kVA rating is supplied as a guide only. Please refer to the manufacturers specification to ensure the correct switch is purchased. **Floor standing enclosure In the interests of continual product improvement all specifications are subject to change without notice DIMENSIONS HxWxD PART NUMBER