2-7/8" OD Drill Pipe, S-135, 2-7/8" HT-PAC

advertisement
Equipment No's:
Ref. Enclosed page
Spec. No.:
DP-2.875-04
TECHNICAL SPECIFICATIONS
2-7/8" OD Drill Pipe, S-135, 2-7/8" HT-PAC Conn's.
New
Premium
80% Remaining Body Wall
DESCRIPTION
Type
Range
Convensional=welded T-J. / Integral=Monoblock
IU, 10.4 #
2
Convensional
TUBE DATA
Material grade
Internal plastic coating
Tube body OD x ID
Wall thickness, nominal
Cross Sectional Area
Polar Sectional Modulus
Tensile yield pipe
Torsional yield pipe
80% Torsional Yield
Connection type
Material grade
Hardbanding
OD x ID
B.S.R.
Tensile yield tooljoint
Torsional yield tooljoint
Make up torque (Max.)
Tool-joint/Drill-pipe torsional ratio
Drift diameter
Type of elevator shoulder
S-135
TC-2000
2,151
2,730
inch
2,875
0,362
inch
2,858
inch2
3
3,204
inch
385 800
lbf
1 716
kN
20 800
lbf-ft
28,2
kNm
16 640
lbf-ft
22,6
kNm
CONNECTIONS DATA
inch
x:1
lbf
kN
lbf-ft
kNm
lbf-ft
kNm
0,00135582
=> 0.80
*
inch
2-7/8" HT-PAC
120 ksi
None / TCS Titanium
1,500
2,945
3,125
1,500
NA
273 000
1 214
7 000
9,5
4 200
5,7
NA
273 000
1 214
8 500
11,5
5 100
6,9
0,41
0,53
1,375
18°
29 750
psi
205
Mpa
29 700
psi
Collapse pressure
205
MPa
10,41
lbs/ft
Adjusted weight
15,5
kg/mtr
328
lbs
Approx weight each joint
149
kg
0,184
gal/ft
Capacity
2,29
ltr/mtr
0,160
gal/ft
Open end displacement
1,99
ltr/mtr
0,344
gal/ft
Closed end displacement
4,27
ltr/mtr
31,5
ft
Built In Length (shoulder to shoulder)
9,6
mtr.
Calculated using nominal OD & ID. Safety & Dope friction factor used: 1.0
Connection data from Grant Prideco
* API generally recommends a torsional ration of 0.80 or larger
Values herein is meant as guidelines only. Odfjell will not be held liable for any damage or injuries !
http://www.ows.no/Legal-Notice
Docs. # 1063589
Frb - 11.12.2014
Burst pressure
2,151
0,290
2,220
2,456
299 800
1 334
15 950
21,6
12 760
17,3
27 200
188
25 600
177
String number:
Joints:
Individual serial numbers:
OWS-DP-2785
200
OWS-2300 to OWS-2499
OWS-DP-2786
300
OWS-2500 to OWS-2799
OWS-DP-2788
480
OWS-3200 to OWS-3679