IGS O.C.E.M. S.p.A. ICAO Guidance Sign Compliance: ICAO Annex 14 NATO STANAG 3316 IGS Applications How to order ICAO signs, model IGS, are designed for use on airport taxiways and runways to mark taxi routes and intersections. Colours may be black on yellow, yellow o n black, or white on red depending on the application as defined by ICAO, Annex 14. IGS signs may be used as guidance markers in compliance with STANAG Specs too. To determine the exact number of modules to fit your message, contact OCEM. To construct the catalogue number, add to the basic part number the size code, the number of faces and the number of modules. If required, any option can be added. Floor flanges included; anchor bolts not included. Order isolation transformer(s), Features I G S ï Designed in 150/5345-44 ï Structural integrity assured by ext aluminium panels ï Matt black external finishing ï Metric hardware ï Long life fluorescent lamps Number of Faces : ï Modular design with uniform leg spacing 1 = Single Face 2 = Double Face ï Two lamps per module, each powered through a dedicated single-lamp electronic ballast for maximum reliability Number of Modules : 1 to 4* compliance with FAA ruded ï SUNLIFE 6111 polycarbonate sign faces with translucent messages ï Message on one or both faces ï Breakable couplings may be pre -installed on concrete pad and sign lowered onto them for easy installation ï Enclosed power entry through protective flexible pipe ï ï ï ï eventual transformer housing with baseplate and gasket, pipe elbow and connector kit separately. The colours of the sign faces and the legends must be specified for each sign. Multiple messages and colours may appear on a sign face. W hen facing side A, the power entry is on the right. Orders should always specify the message orientation. External power disconnecting switch breaks all electrical connections to the sign for safe maintenance Operates from 1 step (6.6 A) or 3 steps (4.8 A to 6.6 A) or 5 steps (2.8 A to 6.6 A) series lighting circuit through isolating transformers. See TAB LE B on this page for isolating transformer choice Constant average sign illuminance (widely exceeding ICAO Specs) at any series current step from 2.8 A through 6.6 A. See TABLE A on this page for illuminance data Power required to CCR per module: £150 VA at 6.6 A, £200 VA at 4.8 -6.6 A, £250 VA at 2.8-6.6 A ï Power factor not less than 0.90 at any series current step from 2.8 A through 6.6 A ï Operating temperature:-20°C to +55°C GOLLAND Sp. z o.o. www.oswietlenielotniskowe.pl Basic Part Number : Size : 3 = Sign, 300 mm Legend Height 4 = Sign, 400 mm Legend Height Options : 00 = Without Lamps * Maximum of (4) Modules for sign. If more modules are required, two signs may be co -located. TABLE A - ILLUMINANCE (in cd/m2) LEGEND HEIGHT of SIZE SIGN FACES 400 mm 300 mm COLOURS RED YELLOW WHITE 800 mm 70 480 560 600 mm 75 540 700 TABLE B - REQUIRED ISOLATING TRANSFORMERS Sign TRANSFORMER Modules RATING 1 200 W 2 300 W 3 400 W 4 2x300 W(1) (1) Use consolidating harness P/N 011.3100 to connect in series the secondary of the two isolation transformers. NOTE: performances may vary depending on type and manufacturer of isolation transformers and CCRs. FT-3.1 May 1999 ul. StyczyÒskiego 83 41-500 Chorzów tel. +48 32 349 17 00, +48 32 349 17 01, fax +48 32 349 17 02 e-mail: centrala@golland.pl Outline Drawings Lamp Modules A Legend Height B 1 2 3 4 991 1976 2961 3946 300 400 838 1038 Dimensions in mm Instruction Manual: UT-MT-238 Shipping Weights and Volumes : Modules Sign Size 1 Kg cu.m 2 Kg cu.m 3 Kg cu.m 4 Kg cu.m 46 0.30 51 0.35 80 0.57 88 0.68 117 0.84 128 1.01 145 1.11 160 1.35 (Legend Height) 300 400 Accessories Part Number Description 013.0010 013.0008 315.3210 315.1227 315.1065 011.2056 011.2003 011.2060 011.2006 011.2080 011.2040 011.2559 011.2558 011.3100 Set of two ryton rings for receptacle support inside pipe elbow Galvanized steel pipe elbow with upper threaded end only Galvanized steel pipe elbow with both threaded ends Base L-867, Class I, Size B, 24î deep Baseplate for L-867 base with gasket and cable clamp Transformer for series circuits FAA L-831 200 W 6.6/6.6 A Transformer for series circuits FAA L-831 200 W 6.6/6.6 A, suitable for secondary grounding Transformer for series circuits FAA L-831 300 W 6.6/6.6 A Transformer for series circuits FAA L-831 300 W 6.6/6.6 A, suitable for secondary grounding Transformer for series circuits FAA L-831 400 W 6.6/6.6 A Transformer for series circuits FAA L-831 400 W 6.6/6.6 A, suitable for secondary grounding 54-E6-E6 Connector kit L-823, 10-12 AWG (6 sq.mm), 0.42î to 0.585î O.D. 54-E4-E4 Connector kit L-823, 8 AWG (10 sq.mm), 0.42î to 0.585î O.D. Consolidating harness Renewal Parts Part Number Description 303.7320 303.7330 760.3615 169.5210 657.0045 150.1964 323.2367 464.0238 470.0218 Breakable coupling for sign with 400 mm lege nd height (type 2434-4) Breakable coupling for sign with 300 mm legend height (type 2434 -3) 30W fluorescent lamp, dia 26 mm G13 lampholder (IP 67) with hardware Single-lamp electronic ballast Electronic card E897 Cable lead with plug ON-OFF switch Rubber cap for switch GOLLAND Sp. z o.o. www.oswietlenielotniskowe.pl ul. StyczyÒskiego 83 41-500 Chorzów tel. +48 32 349 17 00, +48 32 349 17 01, fax +48 32 349 17 02 e-mail: centrala@golland.pl