Surge Arresters Electrical Apparatus Surge Arrester/Type L Fuse Cutout Combination 235-26 Description Cooper Power Systems surge arrester/Type L interchangeable fuse cutout combinations are available in a wide variety of both arrester and fuse cutout designs. Surge arresters are available in silicone rubber (UltraSIL™ polymer-housing) or porcelain-housing in heavy-duty, normal-duty or heavy-duty riser pole classifications, and UltraSIL Polymer-Housed Evolution™ surge arrester designs in ratings 3-36 kV. Type L fuse cutouts are available with silicone rubber (UltraSIL polymerinsulated) or porcelain insulators for both 15 kV and 27 kV voltage ratings. Extra creepage designs are available for porcelain Type L cutouts to meet the user’s application needs. Cutouts are available with a 100 A or 200 A fuseholder or with a 300 A disconnect blade. Type L cutouts will also accommodate a Cooper Power Systems ELF™ full range current-limiting fuse and Tandem ELF backup fuse with series fuse link (refer to catalog section 240-66 for more detailed information on the ELF fuse and catalog section 240-67 for Tandem ELF). Combining the functions of a distribution-class surge arrester with a fuse cutout provides the convenience of a compact, efficient unit with less pole-top hardware. Combining these units also provides easier installation, handling and procurement. All surge arresters used in the surge arrester/Type L fuse cutout combinations have been tested to, and meet or exceed, all requirements of IEEE Std C62.11™-2005 standard, “IEEE Standard for MetalOxide Surge Arresters for Alternating Current Power Circuits”. UltraSIL polymer-insulated and porcelain Type L cutouts have been tested to and meet, or exceed, all requirements set forth by the latest revisions of IEEE Std C37.41™2008 and IEEE Std C37.42™-2009 standards. 0812 • Supersedes 0312 Figure 1. UltraSIL polymer-housed surge arrester/UltraSIL polymer-insulated Type L fuse cutout combination. (Fuse link not included.) Construction Connectors/Brackets Surge arrester/Type L fuse cutout combination comes complete with a crossarm mounting bracket for application on the utility pole crossarm. Standard arrester line and ground terminal hardware includes a silicon bronze nut, a stainless steel wire clamp and a line lead. The arrester line and ground terminal fits a conductor range of #6 (.184” diameter) to 2/0 standard (.418” diameter). Figure 1 shows an UltraSIL polymerhoused surge arrester/UltraSIL polymer-insulated Type L fuse cutout combination. Fuse links are not included in this package. Refer to catalog section K-SEC 100 for ordering information about Cooper Power Systems fuse links. Surge arrester/Type L fuse cutout combination includes, as a standard, a tin plated bronze parallel-groove connector on the cutout. The parallelgroove connector fits a conductor range of #8 solid (.128” diameter) to 250 MCM (.575” diameter). A tin plated bronze eyebolt and large eyebolt connector options are also available. The eyebolt connector fits a conductor range of #8 solid (.128” diameter) to 2/0 standard (.418” diameter) and the large eyebolt connector fits a conductor range of #8 solid (.128” diameter) to 250 mcm (.575” diameter). Surge arrester/Type L fuse cutout combinations include a heavyduty NEMA® crossarm mounting bracket to withstand the mechanical forces generated during fault current interruptions when using an expulsion fuse link. Surge arrester/ Type L fuse cutouts are also available with an extended crossarm mounting bracket or without brackets. 1 Surge Arrester/Type L Fuse Cutout Combinations To specify the appropriate connector and bracket options, simply change the fifth and sixth digits of the catalog number as shown in Table 3. (Example: S4B1E1A003D0A UltraSIL polymer-insulated cutout with digits 5 and 6 equaling E1, will include an eyebolt connector and the NEMA® crossarm mounting bracket with a 10 kV UltraSIL polymer-housed HD VariSTAR™ arrester.) Consult your Cooper Power Systems representative for other connector/ bracket options. A G 10.78” (274 mm) 1.43” (36.3 mm) D 4.13” (105 mm) 5.16” (131 mm) Dimensions Figure 2 shows an outline drawing of an UltraSIL polymer-housed surge arrester/UltraSIL polymer-insulated Type L fuse cutout combination. Figure 3 shows an outline drawing of an UltraSIL polymer-housed surge arrester/porcelain Type L fuse cutout combination. Figure 4 shows an outline drawing of porcelain-housed surge arrester/porcelain Type L fuse cutout combination. Porcelain arresters are not available in combination with UltraSIL polymerinsulated Type L cutouts. F C Figure 2. UltraSIL polymer-housed surge arrester/UltraSIL polymer-insulated Type L fuse cutout combination. B A 2.34” (60 mm) 10.78” (274 mm) G 4.13”(105 mm) TO 5.16”(131 mm) 12.87” (327 mm) 3.87” (98 mm) D D 1.43” (36.3 mm) 4.13”(105 mm) TO 5.16”(131 mm) F E F C C Figure 3. UltraSIL polymer-housed surge arrester/porcelain Type L fuse cutout combination. 2 Figure 4. Porcelain-housed surge arrester/porcelain Type L fuse cutout combination. 235-26 Table 1 UltraSIL Polymer-Housed or Porcelain-Housed Surge Arrester/ 15 kV UltraSIL Polymer-Insulated or Porcelain Type L Fuse Cutout Combination Dimensional Data Dimensions* inches (mm) A UltraSIL PolymerHoused Arrester Arrester Rating kV VariSTAR Evolution B Porcelain Arrester** 3 6.9 (175) 7.9 (201) 9.19 (233) C D UltraSIL Polymer- UltraSIL PolymerInsulated and Insulated and Porcelain Type L Porcelain Type L Cutout Cutout 19.68 (500) 13.5 (343) E Porcelain Arrester** F G UltraSIL Polymer- UltraSIL PolymerInsulated and Insulated and Porcelain Type L Porcelain Type L Cutout Cutout 4.72 (120) 8.18 (208) 4.12 (105) 6 7.9 (201) 9.0 (229) 11.67 (296) 19.68 (500) 13.5 (343) 4.72 (120) 8.18 (208) 4.12 (105) 9 9.0 (229) 9.0 (229) 14.77 (375) 19.68 (500) 13.5 (343) 5.34 (136) 8.18 (208) 4.12 (105) 10 9.0 (229) 9.0 (229) 14.77 (375) 19.68 (500) 13.5 (343) 5.34 (136) 8.18 (208) 4.12 (105) 12 10.0 (254) 11.1 (282) 17.25 (438) 19.68 (500) 13.5 (343) 5.96 (151) 8.18 (208) 5.17 (131) 15 11.1 (282) 11.1 (282) 17.25 (438) 19.68 (500) 13.5 (343) 5.96 (151) 8.18 (208) 5.17 (131) 18 12.2 (310) 12.2 (310) 20.97 (533) 19.68 (500) 13.5 (343) 6.58 (167) 8.18 (208) 5.17 (131) 21 13.2 (336) 13.2 (336) 20.97 (533) 19.68 (500) 13.5 (343) 6.58 (167) 8.18 (208) 5.17 (131) 24 14.3 (363) 14.3 (363) 24.07 (611) 19.68 (500) 13.5 (343) 7.20 (183) 8.18 (208) 5.17 (131) 27 15.3 (389) 15.3 (389) 24.07 (611) 19.68 (500) 13.5 (343) 7.20(183) 8.18 (208) 5.17 (131) 30 16.4 (417) 16.4 (417) 27.79 (706) 19.68 (500) 13.5 (343) 7.82 (199) 8.18 (208) 5.17 (131) 36 18.5 (470) 18.5 (470) 27.79 (706) 19.68 (500) 13.5 (343) 7.82 (199) 8.18 (208) 5.17 (131) * Refer to Figures 2 and 3. **Dimensions pertain to normal-duty, heavy-duty and heavy-duty riser pole VariSTAR porcelain arresters. Table 2 UltraSIL Polymer-Housed or Porcelain-Housed Surge Arrester/ 27 kV UltraSIL Polymer-Insulated or Porcelain Type L Fuse Cutout Combination Dimensional Data Dimensions* inches (mm) A UltraSIL PolymerHoused Arrester Arrester Rating kV VariSTAR Evolution B Porcelain Arrester** 3 6.9 (175) 7.9 (201) 9.19 (233) D C UltraSIL Polymer- UltraSIL PolymerInsulated and Insulated and Porcelain Type L † Porcelain Type L † Cutout Cutout 25.04 (636) 14.09 (358) E Porcelain Arrester** F UltraSIL PolymerInsulated and Porcelain Type L † Cutout G UltraSIL PolymerInsulated and Porcelain Type L † Cutout 4.72 (120) 10.12 (257) 4.12 (105) 6 7.9 (201) 9.0 (229) 11.67 (296) 25.04 (636) 14.09 (358) 4.72 (120) 10.12 (257) 4.12 (105) 9 9.0 (229) 9.0 (229) 14.77 (375) 25.04 (636) 14.09 (358) 5.34 (136) 10.12 (257) 4.12 (105) 10 9.0 (229) 9.0 (229) 14.77 (375) 25.04 (636) 14.09 (358) 5.34 (136) 10.12 (257) 4.12 (105) 12 10.0 (254) 11.1 (282) 17.25 (438) 25.04 (636) 14.09 (358) 5.96 (151) 10.12 (257) 5.17 (131) 15 11.1 (282) 11.1 (282) 17.25 (438) 25.04 (636) 14.09 (358) 5.96 (151) 10.12 (257) 5.17 (131) 18 12.2 (310) 12.2 (310) 20.97 (533) 25.04 (636) 14.09 (358) 6.58 (167) 10.12 (257) 5.17 (131) 21 13.2 (336) 13.2 (336) 20.97 (533) 25.04 (636) 14.09 (358) 6.58 (167) 10.12 (257) 5.17 (131) 24 14.3 (363) 14.3 (363) 24.07 (611) 25.04 (636) 14.09 (358) 7.20 (183) 10.12 (257) 5.17 (131) 27 15.3 (389) 15.3 (389) 24.07 (611) 25.04 (636) 14.09 (358) 7.20 (183) 10.12 (257) 5.17 (131) 30 16.4 (417) 16.4 (417) 27.79 (706) 25.04 (636) 14.09 (358) 7.82 (199) 10.12 (257) 5.17 (131) 36 18.5 (470) 18.5 (470) 27.79 (706) 25.04 (636) 14.09 (358) 7.82 (199) 10.12 (257) 5.17 (131) * Refer to Figures 2 and 3. **Dimensions pertain to normal-duty, heavy-duty and heavy-duty riser pole VariSTAR porcelain arresters. † Dimensions pertain to 27 kV, 150 kV BIL UltraSIL polymer-insulated cutouts and 27 kV, 125 kV, and 150 kV porcelain cutouts. ORDERING INFORMaTION To order a Cooper Power Systems cutout combinations complete the appropriate catalog number shown in Table 3 on the following page. 3 Surge Arrester/Type L Fuse Cutout Combinations TABLE 3 UltraSIL Polymer-Insulated and Porcelain Type L Cutout Combination Numbering System 1 2 3 4 5 6 7 8 9 S 4 B 1 E 1 A 0 0 10 11 12 13 1 C 0 A 13. Arrester Ground Terminal Hardware A = Flat Washer (SS), Terminal Clamp (SS), Hex Nut (SiBrz)* * Standard arrester ground terminal hardware. 12. Arrester Line Terminal Hardware 0=Term. Clamp (SS), Hex Nut (SiBrz), Leadwire * † * Standard arrester line terminal hardware. † 15 kV Type L cutouts w/arrester use 11.0” leadwire. † 27 kV Type L cutouts w/arrester use 9.0” leadwire. 11. Arrester kV Rating A = 3 kV D = 10 kV B = 6 kV E = 12 kV C = 9 kV F = 15 kV G = 18 kV H = 21 kV J = 24 kV K = 27 kV L = 30 kV M = 36 kV 10. Arrester Type 1 = UltraSIL Polymer-Housed ND VariSTAR Arrester* A = Porcelain ND VariSTAR Arrester † 3 = UltraSIL Polymer-Housed HD VariSTAR Arrester* C = Porcelain HD VariSTAR Arrester †† 5 = UltraSIL Polymer-Housed RP VariSTAR Arrester* 8 = UltraSIL Polymer-Housed Evolution Arrester HD/RP** * See UltraSIL Polymer-Housed VariSTAR arrester catalog section 235-35 for further information. ** See UltraSIL Polymer-Housed Evolution arrester catalog section 235-99 for further information. † See ND VariSTAR Type AZS arrester catalog section 235-73 for further information. †† See HD VariSTAR Type AZL catalog section 235-60 for further information. 8 & 9. Combo Info: W/Arrester = 00 W/ELF - Refer to Table 4 (15 kV) or Table 5 (27 kV) for ELF code.* W/Tandem ELF - Refer to Table 6 (15 kV) or Table 7 (27 kV) for Tandem ELF code.** 7. Packaging * Refer to ELF fuse catalog 240-66 for further detail. ** Refer to Tandem ELF fuse catalog section 240-67 for further detail. A=INDIVIDUAL (STD) 6. Bracket/Hardware Options: 0 = No Bracket 5 = Same as option 1 with additional arrester mounting hardware (Figure 8) 1 = NEMA "B" BKT, BACK STRAP & HARDWARE KIT 6 = same as option 3 with additional arrester (5” BOLTS) (Figure 4) mounting hardware (Figure 8) 2 = NEMA "B" BKT, BACK STRAP & hardware kit 7 = NEMA "b" bkt, back strap & hardware kit (6.5" (6" bolts) (Figure 4) bolts) (Figure 4) 3 = EXTENDED BKT, BACK STRAP & HARDWARE KIT 8 = NEMA "D" PolE Mounting bkt and standard (5” BOLTS) (Figure 4) "L" bkt (Figure 5) 4 = NEMA "D" POLE MOUNTING BKT and EXTENDED "L" BKT (Figure 5) 5. Term. Option: E = EYEBOLT connectors #8 solid (.128" Dia) to 2/0 str (.419" Dia) (Figure 7) L = LARGE EYEBOLT connectors #6 solid (.162 Dia) to 250 MCM (.575" Dia) P = PARALLEL GROOVE connectors (TOP CONNECTOR VERTICAL CABLE ENTRY BOTTOM CONNECTOR HORIZONTAL CABLE ENTRY) #8 solid (.128 Dia) to 250 MCM (.575 Dia) (Figure 6) R = BOTTOM Parallel Groove CONNECTOR ROTATED 90 DEGREES (TOP CONNECTOR VERTICAL CABLE ENTRY BOTTOM CONNECTOR VERTICAL CABLE ENTRY) 4. Fuse Holder: 0 = NONE A=100 A HIGH INTERRUPTING † 1 = 100 A STD INTERRUPTING E = ELF FUSE 2 = 200 A † T = TANDEM ELF FUSE 3 = 300 A DISCONNECT † Fuse holders include an arc shortening rod and must be used with removable buttonhead fuse links. 2 & 3. Voltage and Insulation Ratings 4B = 15.5 kV, 110 kV BIL 9C = 27 kV, 125 kV BIL * 9D = 27 kV, 150 kV BIL * Only available in porcelain Type L cutout. 1. UltraSIL Polymer-Insulated or Porcelain Type L Cutout S = UltraSIL Polymer-Insulated Type L Cutout L = Porcelain Type L Cutout 4 NOTE: Porcelain arresters are not available in combination with UltraSIL polymer-insulated Type L cutouts. 235-26 Table 4 ELF Fuse Ratings for 15 kV UltraSIL Polymer-Insulated and Porcelain Type L Fuse Cutouts ELF Fuse Rating Code* Digit 8 Digit 9 3 A 3 B 3 C 3 D 3 E 3 F 3 G 3 H 3 J 3 K 3 L 4 A 4 B 4 C 4 D 4 E ELF Fuse Ratings Voltage kV Current A 8.3 6 8.3 8 8.3 12 8.3 18 8.3 20 8.3 25 8.3 30 8.3 40 8.3 50** 8.3 65** 8.3 80** 15.0 6 15.0 8 15.0 12 15.0 18 15.0 20 Continuous Current Ratings Aa 25 °C 8 12 18 25 27 34 43 50 68 78 95 8 12 18 25 27 40 °C 7 11 17 24 26 33 41 48 65 75 91 7 11 17 24 26 55 °C 6 11 16 23 25 31 39 46 62 71 87 6 11 16 23 25 Maximum Interrupting Current A rms symmetrical 31000 31000 31000 31000 31000 31000 31000 31000 31000 31000 31000 20000 20000 20000 20000 20000 a For temperatures other than listed, a deration factor of 0.26% per °C can be applied. * Replace digits 8 and 9 of the catalog number with the correct ELF fuse rating codes. ** Double-barrel design Note: For more information regarding the ELF fuse, refer to catalog section 240-66. Table 5 ELF Fuse Ratings for 27 kV UltraSIL Polymer-Insulated and Porcelain Type L Fuse Cutouts ELF Fuse Rating Code* Digit 8 Digit 9 3 A 3 B 3 C 3 D 3 E 3 F 3 G 3 H 3 J 3 K 3 L 4 A 4 B 4 C 4 D 4 E 4 F 4 G 4 H 4 J 5 A 5 B 5 C 5 D 5 E 5 F 5 G ELF Fuse Ratings Voltage kV Current A 8.3 6 8.3 8 8.3 12 8.3 18 8.3 20 8.3 25 8.3 30 8.3 40 8.3 50** 8.3 65** 8.3 80** 15.0*** 6 15.0*** 8 15.0*** 12 15.0*** 18 15.0*** 20 15.0*** 25 15.0*** 30** 15.0*** 40** 15.0*** 50** 23.0 6 23.0 8 23.0 12 23.0 18 23.0 20 23.0 25** 23.0 30** Continuous Current Ratings Aa 25 °C 40 °C 55 °C 8 7 6 12 11 11 18 17 16 25 24 23 27 26 25 34 33 31 43 41 39 50 48 46 68 65 62 78 75 71 95 91 87 8 7 6 12 11 11 18 17 16 25 24 23 27 26 25 34 33 31 43 41 39 50 48 46 68 65 62 8 7 6 12 11 11 18 17 16 25 24 23 27 26 25 34 33 31 43 41 39 Maximum Interrupting Current A rms symmetrical 31000 31000 31000 31000 31000 31000 31000 31000 31000 31000 31000 43000 43000 43000 43000 43000 43000 43000 43000 43000 31000 31000 31000 31000 31000 1300 1300 a For temperatures other than listed, a deration factor of 0.26% per °C can be applied. * Replace digits 8 and 9 of the catalog number with the correct ELF fuse rating codes. ** Double-barrel design ***These ELF fuses have been tested and approved for a 17.2 kV application. Note: For more information regarding the ELF fuse, refer to catalog section 240-66. 5 Surge Arrester/Type L Fuse Cutout Combinations Table 6 Tandem ELF Fuse Ratings for 15 kV UltraSIL Polymer-Insulated or Porcelain Type L Cutouts Tandem ELF Fuse Rating Code* Digit 8 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 Digit 9 0 A B C D E F G H J K L M N P 0 A B C D E F G H J K L M N P Companion II Fuse Ratings** Voltage (kV) 8.3 8.3 8.3 8.3 8.3 8.3 8.3 8.3 8.3 8.3 8.3 8.3 8.3 8.3 8.3 15.0 † 15.0 † 15.0 † 15.0 † 15.0 † 15.0 † 15.0 † 15.0 † 15.0 † 15.0 † 15.0 † 15.0 † 15.0 † 15.0 † 15.0 † Current (A) 25 25 25 25 25 25 25 25 25 25 25 25 25 25 25 25 25 25 25 25 25 25 25 25 25 25 25 25 25 25 * Replace digits 8 & 9 of the catalog number with the correct Tandem ELF fuse rating codes. ** Digit 8 defines the Tandem ELF fuse voltage rating with the Companion II fuse current rating. *** Digit 9 defines the Tandem ELF fuse link current rating. X-Link=1/3-2A, D-Link=3-20A. † 15kV Companion II fuses have been tested and are approved for 17.2 kV applications. Note: For more information regarding Tandem ELF fuse refer to catalog section 240-67. 6 Fuse Link Current Ratings*** (A) None 0.33 0.50 0.75 1 1.25 1.50 2 3 4 5 7 10 15 20 None 0.33 0.50 0.75 1 1.25 1.50 2 3 4 5 7 10 15 20 Maximum Interrupting Current A rms Symmetrical 50,000 50,000 50,000 50,000 50,000 50,000 50,000 50,000 50,000 50,000 50,000 50,000 50,000 50,000 50,000 43,000 43,000 43,000 43,000 43,000 43,000 43,000 43,000 43,000 43,000 43,000 43,000 43,000 43,000 43,000 235-26 Table 7 Tandem ELF Fuse Ratings for 27 kV UltraSIL Polymer-Insulated or Porcelain Type L Cutouts Tandem ELF Fuse Rating Code* Digit 8 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 Digit 9 0 A B C D E F G H J K L M N P 0 A B C D E F G H J K L M N P 0 A B C D E F G H J K L M N P Companion Fuse Ratings** Voltage (kV) 8.3 8.3 8.3 8.3 8.3 8.3 8.3 8.3 8.3 8.3 8.3 8.3 8.3 8.3 8.3 15.0 † 15.0 † 15.0 † 15.0 † 15.0 † 15.0 † 15.0 † 15.0 † 15.0 † 15.0 † 15.0 † 15.0 † 15.0 † 15.0 † 15.0 † 23.0 23.0 23.0 23.0 23.0 23.0 23.0 23.0 23.0 23.0 23.0 23.0 23.0 23.0 23.0 Current (A) 25 25 25 25 25 25 25 25 25 25 25 25 25 25 25 25 25 25 25 25 25 25 25 25 25 25 25 25 25 25 25 25 25 25 25 25 25 25 25 25 25 25 25 25 25 Fuse Link Current Ratings*** (A) None 0.33 0.50 0.75 1 1.25 1.50 2 3 4 5 7 10 15 20 None 0.33 0.50 0.75 1 1.25 1.50 2 3 4 5 7 10 15 20 None 0.33 0.50 0.75 1 1.25 1.50 2 3 4 5 7 10 15 20 Maximum Interrupting Current A rms Symmetrical 50,000 50,000 50,000 50,000 50,000 50,000 50,000 50,000 50,000 50,000 50,000 50,000 50,000 50,000 50,000 50,000 43,000 43,000 43,000 43,000 43,000 43,000 43,000 43,000 43,000 43,000 43,000 43,000 43,000 43,000 31,000 31,000 31,000 31,000 31,000 31,000 31,000 31,000 31,000 31,000 31,000 31,000 31,000 31,000 31,000 * Replace digits 8 & 9 of the catalog number with the correct Tandem ELF fuse rating codes. ** Digit 8 defines the Tandem ELF fuse voltage rating with the Companion II fuse current rating. *** Digit 9 defines the Tandem ELF fuse link current rating. X-Link=1/3-2A, D-Link=3-20A. † 15 kV Companion II fuses have been tested and are approved for 17.2 kV applications. Note: For more information regarding Tandem ELF fuse refer to catalog section 240-67. 7 Surge Arrester/Type L Fuse Cutout Combination ADDITIONAL INFORMATION This catalog section has details on surge arrester/Type L fuse cutout combinations regarding dimensions, ratings and ordering information. For detailed information on surge arresters or Type L fuse cutouts and links please refer to the following: n 235-60 VariSTAR AZL Heavy-duty Porcelain-Housed Arrester Catalog Section n 235-73 VariSTAR AZS Normal-duty Porcelain-Housed Arrester Catalog Section n 235-35 UltraSIL Polymer-Housed VariSTAR Distribution-Class Surge Arrester Catalog Section n 235-99 UltraSIL Polymer-Housed Evolution Distribution-Class Surge Arrester Catalog Section n 327-30 UltraSIL Polymer-Insulated and Porcelain Type L Open Distribution Cutout Catalog Section n 240-66 ELF Current-Limiting Drop Out Fuse Catalog Section n 240-67 Tandem ELF Fuse Catalog Section n K-SEC 100 Edison™ Links Catalog Section n S235-26-1 UltraSIL PolymerInsulated and Porcelain Type L Open Distribution Cutout Installation Instructions n B327-11011 Type L Cutout Product Improvements n CP-9618 Type L Open Distribution Cutout Certified Test Report n R327-01-1 Type L Interchangeable Cutouts, Mounting Frames, Fuseholders, and Disconnect Blades–Industry Interchangeable Cutouts Cross Reference Please contact your Cooper Power Systems representative for information on options, pricing and availability. © 2012 Cooper Industries. All Rights Reserved. Cooper Power Systems, VariSTAR, Edison, UltraSIL, Evolution, and ELF are valuable trademarks of Cooper Industries in the U.S. and other countries. You are not permitted to use the Cooper Trademarks without the prior written consent of Cooper Industries. NEMA® is a registered trademark of the National Electrical Manufacturers Association. IEEE Std C62.11™-2005, IEEE Std C37.41™-2008, and IEEE Std C37.42™2009 standards are trademarks of the Institute of Electrical and Electronics Engineers, Inc., (IEEE). This publication/product is not endorsed or approved by the IEEE One Cooper | www.cooperpower.com | Online 2300 Badger Drive Waukesha, WI 53188 USA