Chapter 3.3 DC voltmeters • Given a basic PMMC movement with sensitivity IFSD and coil resistance Rm, What is the maximum voltage that can be measured? IFSD VFSD Rm • Clearly, this value VFSD , is IFSD Rm, since this is the voltage that will cause IFSD to flow in the PMMC ammeter. • For a typical 50µA, 2kΩ PMMC VFSD is 0.1V • As before, the consideration is how can we extend this range? • With the ammeter a shunt was added to divert the excess current from the PMMC meter. Here we want to limit the current caused by voltages higher than VFSD to be <= IFSD. We therefore want to add resistance in series with the movement • We call this resistor a multiplier. From this arrangement, we can then say the following: RT = where VT I FSD RT = RS + Rm RS = RT − Rm V RS = T − Rm I FSD Example Convert a 50µA, 3kΩ PMMC into a 0-10VDC voltmeter. 10V RS = − 3kΩ = 197kΩ 50 ×10 − 6 The voltmeter looks like this: 197k 3k IFSD 0-10V EE11A Handouts Chapter 3.3 Prepared by: Mr. Fasil Muddeen 1 © 2001 • What is the total resistance of the voltmeter? – 200k Voltmeter Sensitivity • We defined the sensitivity of a measurement system before. – For PMMC it is usually taken as IFSD • For a voltmeter it is defined as: Total Resistance of meter S= Range of voltmeter • The units are Ω /V • Note that this can also be stated as: 1 S= I FSD • Therefore for the above example S = 20kΩ/V • We can use this to derive an alternative expression for the multiplier resistor, namely: RS = S × Range − Rm • Revisiting our example, we get: RS = S × Range − Rm Ω RS = 20 × 103 ×10V − 3 ×103 Ω V ∴ RS = 197kΩ Multi-range voltmeters • How can we extend the range of the basic voltmeter to encompass several ranges? • Consider this: Rm V1 R1 R2 R3 V2 V3 V4 Co m • As before, we can add multipliers for each range to create a multi-range voltmeter. • Does this method suffer from any disadvantages like in the analogous case for the ammeter? – Does it require a make before break switch? • Let us examine another calculation: Example: Using a 1mA, 100Ω PMMC movement, design a multi- range voltmeter with the following ranges: 0-10V, 0-50V, 0-250V and 0-500V. Solution: EE11A Handouts Chapter 3.3 Prepared by: Mr. Fasil Muddeen 2 © 2001 What is the maximum voltage measurable by the given PMMC? V= 1mA × 100Ω = 0.1V Therefore we need a multiplier for all ranges Rm R1 10 R2 50 R3 250 R4 500 Com • From before: RS = S × Range − Rm • S = 1/1mA = 1000Ω/V • Therefore: • Similarly: R1 = S × Range − Rm R1 = 1000Ω / V ×10 −100 ∴ R1 = 9900Ω R2 = S × Range − Rm R2 = 1000Ω / V × 50 − 100 ∴ R2 = 49.9 kΩ R3 = S × Range − Rm R3 = 1000Ω / V × 250 − 100 ∴ R3 = 249.9 kΩ; and R4 = 499.9 kΩ • Summarising the values obtained: R1 9900 R2 49.9k R3 249.9k R4 499.9k • Note the non-standard values for the shunt resistors. • This is the main disadvantage of this type of approach to making a multi-range voltmeter. • Let us consider another approach • Using the same PMMC as in the previous example, but with the following circuit. EE11A Handouts Chapter 3.3 Prepared by: Mr. Fasil Muddeen 3 © 2001 Rm R1 R2 2 R3 R4 3 1 4 5 • Here the multiplier is composed of a series connection of resistors. • Would the input ranges be increasing from 1 to 5 or from 5 to 1? • From our previous discussions, position 1 would represent the basic 0.1V range of the PMMC. • For position 2 the 0-10V range: R1 = S × Range − Rm R1 = 1000Ω / V ×10 −100 ∴ R1 = 9900Ω • For position 3, the 0 to 50V range: RS = S × Range − Rm RS = 1000Ω / V × 50 − 100 ∴ RS = 49.9kΩ But RS = R2 + R1 ; ∴ R2 = 49.9k − 9.9k = 40k • For position 4, the 0 to 250V range: RS = S × Range − Rm RS = 1000Ω / V × 250 −100 ∴ RS = 249.9kΩ But RS = R3 + R2 + R1 ; ∴ R3 = 249.9k − 40k − 9.9 k = 200 k • Finally for position 5, the 0 to 500V range: RS = S × Range − Rm RS = 1000Ω / V × 500 − 100 ∴ RS = 499.9kΩ But RS = R4 + R3 + R2 + R1 ; ∴ R4 = 499.9k − 200 k − 40k − 9.9k = 250 k EE11A Handouts Chapter 3.3 Prepared by: Mr. Fasil Muddeen 4 © 2001 • Summarising as before: R1 Separate Multipliers 9900 Series Multiplier 9900 R2 49.9k 40k R3 249.9k 200k R4 499.9k 250k • Note that in the latter method, only the first resistor, 9.9k, has an odd value. • The remaining values, 40k, 200k and 250k, are all commercially obtainable • When separate multipliers are used for each range, the resulting values for the resistors, 49.9k, 249.9k and 499.9k, are be non-standard. • The series multiplier suffers the same disadvantage as the Ayrton shunt should one resistor open circuit or vary its value. EE11A Handouts Chapter 3.3 Prepared by: Mr. Fasil Muddeen 5 © 2001