BLF Series - dpcvietnam.com

advertisement
RoHS-Compliant
Brushless DC Motor and Driver Package
Motor:
BLF Series
Driver:
200 W/400 W
The BLF Series brushless DC motor, which can
achieve a maximum motor speed of 4000 r/min,
is now available with high-output power of 200 W
and 400 W. With the digital operator, digital setting
and display are possible, offering a wide range of
functions to meet your diverse needs.
왎Product Line
Combination Type The combination type comes with the motor and its dedicated gearhead pre-assembled, which simplifies installation
in equipment. Motors and gearheads are also available separately to facilitate changes or repairs.
쎲 Combination Type – Parallel Shaft Gearhead
쎲 Round Shaft Type
Be sure to purchase connection cables.
Be sure to purchase connection cables.
Output Power Supply
Power
Voltage
200 W
400 W
Output
Power
Model
Gear Ratio
Single-Phase
100-120 VAC
BLF6200A-䡺
5, 10, 15, 20, 30, 50,
100, 200
200 W
Single-Phase
200-240 VAC
BLF6200C-䡺
5, 10, 15, 20, 30, 50,
100, 200
400 W
Three-Phase
200-240 VAC
BLF6200S-䡺
5, 10, 15, 20, 30, 50,
100, 200
Three-Phase
200-240 VAC
BLF6400S-䡺
5, 10, 15, 20, 30, 50,
100, 200
Power Supply Voltage
Model
Single-Phase 100-120 VAC
Single-Phase 200-240 VAC
Three-Phase 200-240 VAC
Three-Phase 200-240 VAC
BLF6200A-A
BLF6200C-A
BLF6200S-A
BLF6400S-A
쎲 Enter the gear ratio in the box (䡺) within the model name.
쎲 Pinion Shaft Type
쎲 Gearhead
Be sure to purchase connection cables.
Output
Power
200 W
400 W
앳 Parallel Shaft Gearhead
Power Supply Voltage
Model
Single-Phase 100-120 VAC
Single-Phase 200-240 VAC
Three-Phase 200-240 VAC
Three-Phase 200-240 VAC
BLF6200A-GFS
BLF6200C-GFS
BLF6200S-GFS
BLF6400S-GFS
쎲 Connection Cables (Sold separately)
앳 Cable Set
The cable set consists of two cables including a motor connection
cable and a signal connection cable.
Length
1m
2m
3m
5m
7m
10m
15m
20m
Model
CC01BLF
CC02BLF
CC03BLF
CC05BLF
CC07BLF
CC10BLF
CC15BLF
CC20BLF
Motor Connection Cable
Output Power of Applicable
Motor (Pinion Shaft Type)
200 W
400 W
Gearhead Model
Gear Ratio
GFS6G䡺
5, 10, 15, 20, 30, 50,
100, 200
쎲 Enter the gear ratio in the box (䡺) within the model name.
For details, refer to the BLF Series
catalogue (30 W/60 W/120 W).
왎 Features
왎 System Configuration
왎 Timing Chart
왎 I/O Signal Circuits
왎 Operating Methods
Signal Connection Cable
쎲 The BLF Series requires two dedicated cables, one for the motor and the other for signals,
for connection between the motor and driver. Be sure to purchase the connection cable
set.
*Please take note that there are new product number code and
accessories. Kindly refer to page 9 to 11 for more information.
1
왎Specifications
쎲 200 W, 400 W
Motor:
/Driver:
Combination Type – Parallel Shaft
Gearhead
BLF6200A-䡺
BLF6200C-䡺
BLF6200S-䡺
BLF6400S-䡺
Round Shaft Type
Rated Output Power (Continuous)
W
Rated Voltage
VAC
Permissible Voltage Range
Rated Frequency
Hz
Power Source
Permissible Frequency Range
Rated Input Current
A
Maximum Input Current
A
Rated Torque
N䡠m
Starting Torque
N䡠m
Rated Speed
r/min
Speed Control Range
r/min
BLF6200A-A
BLF6200C-A
200
Single-Phase 200-240
BLF6200S-A
BLF6400S-A
400
Three-Phase 200-240
Model
Round Shaft Type
Permissible Load Inertia
J⫻10-4 kg䡠m2
-4
Rotor Inertia
J⫻10 kg䡠m
2
Speed Regulation✽
(When digital operator
is used)
Load
Voltage
Temperature
Single-Phase 100-120
Three-Phase 200-240
⫾10%
50/60
⫾5%
4.7
8.8
2.8
5.1
0.65
1.15
1.7
3.4
2.8
5.6
1.3
1.8
3000
80앑4000
8.75
15
0.61
0.66
⫾0.2% max. (0앑Rated torque, at rated speed, at rated voltage, at normal ambient temperature)
⫾0.2% max. (Rated voltage 앐10%, at rated speed, with no load, at normal ambient temperature)
⫾0.2% max. (0앑⫹50˚C, at rated speed, with no load, at rated voltage)
✽ Speed regulation values vary depending on the speed setting method.
Settings from internal speed potentiometer, external speed potentiometer or external DC voltage; Load: ⫾0.5% max., Voltage: ⫾0.5% max., Temperature: ⫾0.5% max.
쎲 Enter the gear ratio in the box (䡺) within the model name.
쎲 The values for each specification apply to the motor only.
왎Common Specifications
Item
Specifications
Speed Setting Method
Select one of the following methods:
䡠 Set using the internal speed potentiometer
䡠 Set using the digital operator: Up to eight speeds
䡠 Set using an accessory external speed potentiometer: PAVR-20KZ (20 k⍀, 1/4 W) (sold separately)
䡠 Set using external DC voltage: 0앑5 VDC or 0앑10 VDC
Acceleration/Deceleration Time
(At 3000 r/min)
0.2앑15 sec. (factory setting: 0.5 sec.) Up to eight speeds using the digital operator
Input Signal (In the remote mode)
Photocoupler input mode Input resistance 3.3 k⍀
Internal power supply voltage: 14 VDC⫾10%
Connectable external voltage: 24 VDC⫾10% (only for source logic)
Source input (factory setting), Sink input/2-wire input mode (factory setting), or 3-wire input mode
CW (START/STOP) input, CCW (RUN/BRAKE) input, STOP-MODE (CW/CCW) input, Speed data select, Alarm reset input, External error input
Names in ( ) apply in the 3-wire input mode.
Output Signal
Open-collector output 4.5앑26.4 VDC, 10 mA max. (5앑10 mA for Speed output)
Speed output (30 pulses/rotation), Alarm output1, Alarm output2
Protective Function✽
When the following are activated, the "Alarm" signal will be output and the motor will coast to a stop. (The motor will stop instantaneously in the event
of an external error.)
䡠 Overload Protection: Activated when the motor load exceeds rated torque for a minimum of 5 seconds.
䡠 Overvoltage Protection: Activated when the voltage applied to the driver exceeds 120 VAC or 240 VAC by a minimum of 20%, a gravitational operation
is performed or a load exceeding the permissible load inertia is driven.
䡠 Undervoltage Protection: Activated when the voltage applied to the driver falls below 100 VAC or 200 VAC by a minimum of 40%.
䡠 Missing Phase Protection: Activated when an error is detected in the signals received from the motor due to poor connection or breakage of the signal
cable, etc.
䡠 Overspeed Protection: Activated when the speed of the motor shaft exceeds 4800 r/min.
䡠 Overcurrent Protection: Activated when an excessive current flows through the driver due to a ground fault, etc.
䡠 CPU Error, EEPROM Error, External Error, Operation Error
Maximum Extension Distance
Time Rating
Motor/Driver Distance: 20.4 m (when a dedicated connection cable is used)
Continuous
✽ With the BLF Series, the motor speed cannot be controlled in a gravitational operation or other application where the motor shaft is turned by the load.
When a load exceeding the permissible load inertia is driven or a gravitational operation is performed, the overvoltage protective function will be activated and the motor will coast to a stop.
2
왎General Specifications
Item
Motor
Insulation Resistance
Dielectric Strength
Temperature Rise
Driver
100 M⍀ or more when 500 VDC megger is applied between the
windings and the case after continuous operation under normal
ambient temperature and humidity.
100 M⍀ or more when 500 VDC megger is applied between the power supply
input terminal and the protective earth terminal, and between the power supply
input terminal and the I/O terminal after continuous operation under normal
ambient temperature and humidity.
Sufficient to withstand 1.5 kV at 50 Hz applied between the
windings and the case for 1 minute after continuous operation
under normal ambient temperature and humidity.
Sufficient to withstand 1.8 kV at 50 Hz applied between the power supply input
terminal and the protective earth terminal for 1 minute, and 3 kV at 50 Hz applied
between the power supply input terminal and the I/O terminal for 1 minute after
continuous operation under normal ambient temperature and humidity.
Temperature rise of the windings and the case are 50˚C or less,
and 40˚C or less✽1 respectively measured by the thermocouple
method after continuous operation under normal ambient
temperature and humidity.
Temperature rise of heat sink are 50˚C or less measured by the thermocouple
method after continuous operation under normal ambient temperature and
humidity.
Ambient
Temperature
0앑⫹50˚C (non-freezing)
Ambient
Humidity
85% or less (non-condensing)
Altitude
Atmosphere
Operating
Environment
Up to 1000 m above sea level
No corrosive gases or dust. Cannot be used in a radioactive area, magnetic field, vacuum or other special environment
Not subject to continuous vibration or excessive impact
In conformance with JIS C 60068-2-6, "Sine-Wave Vibration Test Method"
Frequency range: 10앑55 Hz Pulsating amplitude: 0.15 mm
Sweep direction: 3 directions (X, Y, Z) Number of sweeps: 20 times
Vibration
Ambient
Temperature
✽2
Storage Condition
⫺25앑⫹70˚C (non-freezing)
Ambient
Humidity
85% or less (non-condensing)
Altitude
Up to 3000 m above sea level
UL, CSA: class A (105˚C) EN: class E (120˚C)
⫺
IP65 (Excluding the mounting surface of the round shaft type and
connectors)
IP20
Insulation Class
Degree of Protection
✽ 1 For round shaft types, please attach to the heat radiation plate (material: aluminum) of the following sizes to maintain a maximum motor case temperature of 90˚C.
䡺-A: 200⫻200 mm, 5 mm thick
BLF6200䡵
BLF6400S-A: 250⫻250 mm, 6 mm thick
䡺) with the model name.
쎲 Enter A, C or S (power supply voltage) in the box (䡵
✽ 2 The storage condition applies to a short period such as a period during transportation.
Note:
쎲 Do not measure insulation resistance or perform the dielectric strength test while the motor and driver are connected.
왎Gearmotor – Torque Table of Combination Type
쎲 Combination Type – Parallel Shaft Gearhead
5
16
600
800
2.9
2.0
5.9
4.3
Gear Ratio
80 r/min
Model
Motor Speed
3000 r/min
4000 r/min
80앑3000 r/min
䡺-䡺
BLF6200䡵
4000 r/min
80앑3000 r/min
BLF6400S-䡺
4000 r/min
Unit ⫽ N䡠m
10
8
300
400
5.9
4.1
11.7
8.6
15
5.3
200
267
8.8
6.1
17.6
12.8
20
4
150
200
11.7
8.1
23.4
17.1
30
2.7
100
133
16.8
11.6
33.5
24.5
50
1.6
60
80
28
19.4
55.9
40.9
100
0.8
30
40
52.7
36.5
70
63
200
0.4
15
20
70
63
70
63
䡺) with the model name.
쎲 Enter A, C or S (power supply voltage) in the box (䡵
쎲 Enter the gear ratio in the box (䡺) within the model name.
쎲 A colored background (
) indicates gear shaft rotation in the same direction as the motor shaft, while the others rotate in the opposite direction.
왎Permissible Overhung Load and Permissible Thrust Load
쎲 Combination Type – Parallel Shaft Gearhead
Permissible Overhung Load
Model
Gear Ratio
5, 10, 15, 20
䡺-䡺
BLF6200䡵
BLF6400S-䡺
30, 50
100, 200
80앑3000 r/min
4000 r/min
80앑3000 r/min
4000 r/min
80앑3000 r/min
4000 r/min
10 mm from Shaft End
N
20 mm from Shaft End
N
550
500
1000
900
1400
1200
800
700
1250
1100
1700
1400
Permissible Thrust Load
N
200
300
400
䡺) with the model name.
쎲 Enter A, C or S (power supply voltage) in the box (䡵
쎲 Enter the gear ratio in the box (䡺) within the model name.
쎲 Round Shaft Type
Permissible Overhung Load
Model
䡺-A
BLF6200䡵
BLF6400S-A
10 mm from Shaft End
N
20 mm from Shaft End
N
Permissible Thrust Load
197
221
The permissible thrust load shall be no greater than half the motor mass.
쎲 Enter A, C or S (power supply voltage) in the box (䡵
䡺) with the model name.
3
왎Permissible Load Inertia of Combination Type: J
쎲 Combination Type – Parallel Shaft Gearhead
Gear Ratio
5
10
15
20
30
50
100
200
37.5
150
338
600
1350
3750
3750
3750
Model
䡺-䡺
BLF6200䡵
BLF6400S-䡺
Unit ⫽ ⫻10-4 kg䡠m2
䡺) with the model name.
쎲 Enter A, C or S (power supply voltage) in the box (䡵
쎲 Enter the gear ratio in the box (䡺) within the model name.
왎Speed – Torque Characteristics
Continuous Duty Region: Continuous operation is possible in this region.
Limited Duty Region: This region is used primarily when accelerating. When a load that exceeds the rated torque is applied continuously for
approximately five seconds, overload protection is activated and the motor coasts to a stop.
䡺-䡺 / BLF6200䡵
䡺-A
BLF6200䡵
BLF6400S-䡺/BLF6400S-A
Starting Torque
Starting Torque
Torque [N·m]
Torque [N·m]
Rated Torque
1.8
1.15
Rated Torque
Limited Duty Region
0.65
0.45
Limited Duty Region
1.3
0.95
Continuous Duty Region
Continuous Duty Region
0
80
1000
2000
Speed [r/min]
3000
0
4000
80
1000
2000
Speed [r/min]
3000
쎲 The characteristics shown above are applicable for the motors only.
䡺) with the model name.
쎲 Enter A, C or S (power supply voltage) in the box (䡵
쎲 Enter the gear ratio in the box (䡺) within the model name.
왎Dimensions (Unit = mm)
쎲Mounting screws are included with the combination type.
쎲 200 W, 400 W
앳 Motor/Parallel Shaft Gearhead
Motor Model
Gearhead Model
BLF6400S-□
BLFM6400-GFS
GFS6G□
Mass: 5.4 kg (Including gearhead)
2
82
50⫾1
L
10
5
35⫾0.5
32
L
CAD
5앑20
60
A652A
30, 50
72
A652B
100, 200
86
A652C
0
BLFM6200-GFS
Gear Ratio
␾22⫺0.021(h7)
24.5
20⫾0.5
Model
BLF6200A-□
BLF6200C-□
BLF6200S-□
M6⫻12 Deep
4⫻␾8.5 Thru
A
15
␾42
䡺104
䡺110
9.5
␾25
104
A
0.5
120⫾
Sensor Cable ␾7, 400 mm Length
Housing: 5557-06R-210 (MOLEX)
Protective Earth
Terminal M4
33
Motor Cable ␾8, 400 mm Length
Housing: 350779-1 (AMP)
0
18.5 ⫺0.1
0
32⫾0.2
6⫺0.03
앳 Key and Key Slot (The key is included with the gearhead)
0
6 ⫺0.03
A⫺A
쎲 At the time of shipment, a parallel key is inserted on the gearhead's shaft.
쎲 Enter the gear ratio in the box (䡺) within the model name.
4
4000
앳 Round Shaft Type
BLF6200A-A, BLF6200C-A, BLF6200S-A, BLF6400S-A
82
10
37⫾1
2
4⫻␾8.5 Thru
0
2
␾14⫺0.018(h7)
0
␾94⫺0.035(h7)
䡺104
Motor: BLFM6200-A, BLFM6400-A
Mass: 2.4 kg
A653
12
0⫾
0.5
15
9.5
104
13
30
Sensor Cable ␾7, 400 mm Length
Housing: 5557-06R-210 (MOLEX)
Protective Earth
Terminal M4
33
Housing: 350779-1 (AMP)
Motor Cable ␾8, 400 mm Length
앳 Driver
앳 Digital Operator
(Detached from the driver)
BLFD200A2, BLFD200C2, BLFD200S2, BLFD400S2
Mass: 1.3 kg
A654
106
130
13.4
17 max.
110
34
7
10.8
12.8
50
95
85
5
17
85
69
4⫻M3⫻4 Deep min.
Slit
앳 Digital Operator Panel Cut-Out
4⫻␾3.5
5
Protective Earth Terminal M4
4⫻R2 max.
34⫾0.1
Protective Earth Terminal M4
19
12.3⫾0.2
2⫻␾4.5 Thru
8⫾0.2
19
69⫾0.1
9.8⫾0.2
쎲 Connection Cables (Sold separately)
L: 1 to 7 m
L
Round Shape Terminal: ICTN2-3.5S or
TMEN2-3.5S (NICHIFU)
L: 1 to 20 m
L
12
␾7
26.67
7.62
앳 Signal Connection Cable
13.8
앳 Motor Connection Cable
␾10
Housing: 5559-06P-210(MOLEX)
Housing: 350780-1 (AMP)
Stick Terminal: ICTNTC-0.3-9.5 or
TMENTC-0.3-9.5 (NICHIFU)
Round Shape Terminal (For Protective Earth):
ICTN2-4M or TMEN2-4M (NICHIFU)
앳 Motor Connection Cable
L: 10 to 20 m
26.67
L
7.62
␾10
Housing: 350780-1(AMP)
Round Shape Terminal: ICTN2-3.5S or
TMEN2-3.5S (NICHIFU)
5
왎Connection and Operation
쎲 Names and Functions of Driver Parts
앳 Digital Operator
Mode Indicator LEDs Unit Indicator LEDs
RUN LED
Digital Operator
RUN Key
ALARM LED
STOP Key
Operation Keys
Internal Speed
Potentiometer
I/O Signal
Connection
Terminals
When the digital operator is detached
Signal Cable
Connection Terminals
Protective
Earth Terminal
Protective
Earth
Terminal
Power Supply Connection Terminals Motor Connection Terminals
Digital Operator Connector CN1
POWER LED
Remote-Control Connector CN2
Sink/Source-Input
Select Switch
Use this switch to select
the sink mode or source
mode for the input circuit.
To use the digital operator remotely from
the driver, connect the cable of the
remote-control kit (sold separately) to
this connector.
External Voltage Select Switch
To set speeds using external DC voltage, set this switch
to 5 V or 10 V in accordance with the voltage supply used.
쎲 I/O Signal
Terminal Name
TH
TH
M0
M1
M2
VH
VM
VL
C3
X0✽1
C0
C1
Signal
Input
X1✽2
X2✽2
X3✽2
X4
X5
Y1
Y2
Y0
C2
Output
Signal Name
N. C.
N. C.
M0 Input
M1 Input
M2 Input
VH Input
VM Input
VL Input
IN-COM1
EXT-ERROR Input
IN-COM0
IN-COM0
2-Wire Mode: CW Input
3-Wire Mode: START/STOP Input
2-Wire Mode: CCW Input
3-Wire Mode: RUN/BRAKE Input
2-Wire Mode: STOP-MODE Input
3-Wire Mode: CW/CCW Input
N. C.
ALARM-RESET Input
ALARM-OUT1 Output
ALARM-OUT2 Output
SPEED-OUT Output
OUT-COM
Function and Operation
Do not connect any signal to this terminal.
Do not connect any signal to this terminal.
These signals are used to select operation data in multi-speed operation.
One of up to eight preset speed data can be selected using the M0, M1 and M2 inputs.
These signals are used to set speeds via an external speed potentiometer or external DC voltage.
Input signal common (0 V)
External error input (Normally closed)
Input signal common
Input signal common
Clockwise direction/stop switch input signal
Start/stop input signal
Counterclockwise direction/stop switch input signal
Run/instantaneous stop input signal
This signal is input to select the motor stop action.
Clockwise/counterclockwise direction input signal
Do not connect any signal to this terminal.
This signal is used to reset alarms.
This signal is output upon generation of an alarm. (Normally closed)
This signal is output upon actuation of the overload protective function or overload warning function. (Normally closed)
30 pulses are output per each rotation of the motor output shaft.
Output signal common
✽ 1 Do not remove the short circuit bar if the EXT-ERROR input is not used.
✽ 2 The functions of the external-input signal terminals X1, X2 and X3 can be changed between the 2-wire input mode and 3-wire input mode. The functions under the 2-wire input mode are
initially assigned to the terminals.
쎲 Digital Operator Indicator
Display
MNTR
Function
Running
Alarm
Monitor mode
Details
A green lamp stays lit while the motor is running.
A red lamp turns on when an alarm occurs.
The motor can be operated in this mode. The motor speed and load condition are displayed during motor operation.
F/R
Direction setting mode
If the digital operator is used to operate the motor, set the motor direction in this mode.
For: Clockwise direction, rEv: Counterclockwise direction
LO/RE
Digital operator/external-input
signal mode
In this mode, set whether to use the digital operator or external I/O signals to input the motor operation/stop signals.
Lo: Digital operator, rE: External-input signals
PRGM
Data setting mode
In this mode, set the data needed to operate the motor.
Operation data (eight speeds and acceleration/deceleration times)
Gear ratio setting/conveyor speed setting
Input mode
Overload warning function
r/min
m/min
%
Motor speed
Conveyor speed
Load factor✽
The speed of the motor or gearhead output shaft is displayed.
An equivalent moving speed of the work on a conveyor or other transfer system is displayed.
The actual load is displayed as a percentage of the rated torque being 100%.
RUN
ALARM
Mode
Display Unit
✽ A maximum error of approximately 20% may generate when the motor is operated at the rated speed under the rated load.
6
쎲 Connection Diagrams
The figure below is a connection diagram for a configuration based on a three-phase 200-240
VAC supply voltage, with the sink/source-input select switch set to the sink side.
앳 Applicable Crimp Terminals
䡠 Power Supply Connection Terminal (M3.5):
Round Terminal with Insulation
Driver
L
L
N
N
POWER
200-240 V 3~
Main Circuit ✽2
␾3.6 mm min.
MOTOR
R
L1
U
S
L2
V
T
L3
W
Motor Cable Connection
3.8 mm max.
Motor
䡠 Protective Earth Terminal (M4):
Round Terminal with Insulation
Driver Ground Connection
Speed setting via an external speed
potentiometer or external DC voltage
✽4
VH
Accessory
PAVR-20KZ
(20 k⍀ 1/4 W)
VM
VL
Not to exceed the
voltage selected by
the external voltage
select switch
✽3
HALL S.
Vcc
Signal Cable Connection
B
C
GND
0V
GND
I/O Signal Connection
⫹14 V
M0
M1
M2
IN-COM0
3.3 k⍀
M0
Internal Input Circuit
M1
M2
C0
Y0
Y1
0V
⫹14 V
I/O Signal Connection
EXT-ERROR
CW
CCW
STOP-MODE
ALARM-RESET
IN-COM0
Y2
C2
Output Circuit
SPEED-OUT:
4.5 to 26.4 VDC,
5 to 10 mA
SPEED-OUT
␾4.1 mm min.
4.8 mm max.
A
Speed Command
Voltage
External Voltage
Select Switch
Speed Selection
Input Signals
Motor Ground
Connection✽1
Control Circuit
9.5 mm max.
PE
6.2 mm max.
after Crimping
Single-Phase 100-120 VAC
Single-Phase 200-240 VAC
Circuit Breaker
7.2 mm max.
Power Supply Connection
Output Signals:
4.5 to 26.4 VDC,
10 mA or less
䡠 I/O Terminals
Use the terminals specified below for connection using
crimp terminals. Please note that the applicable crimp
terminal will vary depending on the size of the wire. The
following terminals can be used with wires of AWG26 to
22.
[Manufacturer: Phoenix Contact]
AI 0.25-6 Applicable cable size
: AWG26 to 24 (0.14 to 0.2 mm2)
AI 0.34-6 Applicable cable size
: AWG22 (0.3 mm2)
ALARM-OUT1
ALARM-OUT2
OUT-COM
3.3 k⍀
X0
Internal Input Circuit
X1
X2
X3
X4
Sink/Source-Input Select Switch
X5
C1
This indicates a
shielded cable.
0V
This indicates
frame or enclosure.
✽ 1 The grounding method will vary depending on the length of the connection cable.
When the connection cable is 7 m or shorter: Connect the protective earth terminal on the connection cable to the protective
earth terminal on the driver.
When the connection cable is 10 m or longer: Connect the protective earth terminal of the motor directly to the grounding point.
✽ 2 The main circuit is insulated to prevent electrical shock resulting from accidental contact by a hand, etc.
✽ 3 The signal cable connection terminals and the signal cable including the shielded cable comprise an ELV circuit, which is
insulated from dangerous voltages only by means of basic insulation. Therefore, connect the shielded cable to the GND point
specified in the connection diagram, instead of connecting it to a protective earth terminal.
✽ 4 The I/O signal connection terminals comprise a SELV circuit, which is insulated from dangerous voltages by means of double
insulation or reinforced insulation.
왎List of Motor and Driver Combinations
쎲 Combination Type – Parallel Shaft Gearhead
쎲 Round Shaft Type
The combination type comes with the motor and parallel shaft gearhead
pre-assembled.
Output
Power
200 W
400 W
Model
BLF6200A-䡺
BLF6200C-䡺
BLF6200S-䡺
BLF6400S-䡺
Motor Model
BLFM6200-GFS
Gearhead Model
Driver Model
GFS6G䡺
BLFD200A2
BLFD200C2
BLFD200S2
BLFD400S2
BLFM6400-GFS
Output
Power
200 W
400 W
Model
BLF6200A-A
BLF6200C-A
BLF6200S-A
BLF6400S-A
Motor Model
BLFM6200-A
BLFM6400-A
Driver Model
BLFD200A2
BLFD200C2
BLFD200S2
BLFD400S2
쎲 Enter the gear ratio in the box (䡺) within the model name.
쎲 Pinion Shaft Type
Output
Power
200 W
400 W
Model
BLF6200A-GFS
BLF6200C-GFS
BLF6200S-GFS
BLF6400S-GFS
Motor Model
BLFM6200-GFS
BLFM6400-GFS
Driver Model
BLFD200A2
BLFD200C2
BLFD200S2
BLFD400S2
7
왎Accessories (Sold separately)
쎲 Remote-Control Kit
The remote-control kit is useful if you want to detach the
digital operator from the driver and install it on the frame of the
equipment, etc., for remote operation.
The kit includes an extension cable for digital operator/driver
connection (2 or 5 m) and a rubber gasket.
Model
BLFHS-02
BLFHS-05
Example of Use
Length: L (m)
2
5
Extension Cable
Rubber Gasket
Digital Operator
This product is manufactured at a plant certified with the
international standards ISO 9001 (for quality assurance) and
ISO 14001 (for systems of environmental management).
Specifications are subject to change without notice.
This catalogue was published in September, 2007.
SINGAPORE ORIENTAL MOTOR PTE LTD
ORIENTAL MOTOR (MALAYSIA) SDN. BHD.
31 Kaki Bukit Road 3, #04-02/04
Headquarters & Kuala Lumpur Office
TECHLINK, Singapore 417818
A-13-1, North Point Offices, Mid Valley City,
TEL: +65-6745-7344
No.1 Medan Syed Putra Utara 59200
FAX: +65-6745-9405
Kuala Lumpur, Malaysia
ORIENTAL MOTOR (THAILAND) CO., LTD.
900, 8th Floor Zone C, Tonson Tower, Ploenchit Road,
Lumpini, Pathumwan, Bangkok 10330 Thailand
TEL: +66-2-251-1871
FAX: +66-2-251-1872
TEL: +60-3-22875778
FAX: +60-3-22875528
Penang Office
TEL: +60-4-6423788
FAX: +60-4-6425788
Customer Support Centre
Japanese Customer Support Centre
TEL: 1800-842-0280 (For Singapore)
TEL: +65-6745-3008
1800-806161
(For Malaysia)
Mailto: j-support@orientalmotor.com.sg
+65-6842-0280 (For Other Countries)
Mailto: support@orientalmotor.com.sg
For more information please contact:
This printed material uses ECF (Elementary
Chlorine Free) paper and soyinks.
This combination is environmentally friendly.
Printed in Japan 07W 4.5K 2906T (B-001A)
Information updated on 1st August 2008:
We have a new product code system that includes motor, driver and connection cable(1/2/3m).
■Product Number Code
BLF 5 12 A - 5 F - 1
➀
➁
➂
➃
⑤ ➅
➆
BLF:BLF Series
2:60mm 4:80mm 5:90mm 6:104mm (Geared Type: 110mm)
3:30W 6:60W 12:120W 20:200W 40 : 400W
A:Single Phase 100~120VAC
C: Single Phase 200~240VAC
S: Three Phase 200~240VAC
①
②
③
④
Series
Motor Frame Size
Output Power(W)
Voltage
⑤
Gear Ratio or Shaft Type Number: 5 ~ 200 (8 types of ratio)
A:Round Shaft Type
S:Parallel Shaft
F:Hollow Shaft Flat Gearhead
⑥
Gear Type
⑦
Provided Connection Cable 1: 1m, 2: 2m, 3: 3m
■Product Line
●Combination Type - Parallel Shaft Gearhead
Output Power
30W
60W
120W
200W
400W
Model
BLF23A- SBLF23C- SBLF23S- SBLF46A- SBLF46C- SBLF46S- SBLF512A- SBLF512C- SBLF512S- SBLF620A-□SBLF620C-□SBLF620S-□SBLF640S-□S-
Motor Model
Gearhead Model
BLFM230-GFS
GFS2G
BLFM460-GFS
GFS4G
BLFM5120-GFS
GFS5G
BLFM6200-GFS
GFS6G□
BLFM6400-GFS
Driver Model
BLFD30A2
BLFD30C2
BLFD30S2
BLFD60A2
BLFD60C2
BLFD60S2
BLFD120A2
BLFD120C2
BLFD120S2
BLFD200A2
BLFD200C2
BLFD200S2
BLFD400S2
● Enter the connection cable length 1(1m), 2(2m), 3(3m) within the model name.
●Combination Type - Hollow Shaft Type Gearhead
Output Power
30W
60W
120W
Model
BLF23A- FBLF23C- FBLF23S- FBLF46A- FBLF46C- FBLF46S- FBLF512A- FBLF512C- FBLF512S- F-
Motor Model
Gearhead Model
BLFM230-GFS
GFS2G FR
BLFM460-GFS
GFS4G FR
BLFM5120-GFS
GFS5G FR
Driver Model
BLFD30A2
BLFD30C2
BLFD30S2
BLFD60A2
BLFD60C2
BLFD60S2
BLFD120A2
BLFD120C2
BLFD120S2
● Enter the connection cable length 1(1m), 2(2m), 3(3m) within the model name.
●Round Shaft Type
Output Power
30W
60W
120W
200W
400W
Model
BLF23A-ABLF23C-ABLF23S-ABLF46A-ABLF46C-ABLF46S-ABLF512A-ABLF512C-ABLF512S-ABLF620A-ABLF620C-ABLF620S-ABLF640S-A-
Motor Model
BLFM230-A
BLFM460-A
BLFM5120-A
BLFM6200-A
BLFM6400-A
Driver Model
BLFD30A2
BLFD30C2
BLFD30S2
BLFD60A2
BLFD60C2
BLFD60S2
BLFD120A2
BLFD120C2
BLFD120S2
BLFD200A2
BLFD200C2
BLFD200S2
BLFD400S2
●Enter the connection cable length 1(1m), 2(2m), 3(3m) within the model name.
9
Accessories (Sold Separately)
Connection Cables
Extension Cables
Flexible Extension Cables
The BLF Series now comes with a cable of 1m, 2m or 3m for a connection between the motor and driver.
When it is necessary to have a connection more than 5m between motor and driver, the motor cable or extension cable must be used.
Use a flexible motor cable if the cable is constantly flexed during motor operation.
■ System Configuration
● Using a Connection Cable (Not using a cable included in the BLF Series)
Please purchase this optional motor cable separately.
zConnection Cable (sold separately)
Length: 5m ~ 20m (5 types)
Motor Connection Cable
Signal Connection Cable
Motor
Driver
● Using an Extension Cable (Using a cable included in BLF Series)
Please use the optional extension cable(sold separately) and connect with the provided cable.
Use a flexible motor cable if the cable is constantly flexed during motor operation.
xExtension Cable (sold separately)
cFlexible Extension Cable (sold separately)
Connection Cable (included)
Length: 1m ~20m (8 types)
Length: 1m, 2m, 3m
Motor Cable
Motor Cable
Signal Cable
Signal Cable
Driver
Motor
Note:
●Keep the cable length below 23m when connecting a cable included in the BLF Series and an extension cable.
z Connection Cables (Sold Separately)
●Dimensions unit: (mm)
◇Motor Connection Cable L:5m、7m
L
7.6
ROUND SHAPE TERMINAL: ICTN2-3.5S OR TMEN2 - 3.5S (NICHIFU)
Signal Connection Cable
26.7
Motor Connection Cable
10
●Cable Set
HOUSING: 350780 - 1(AMP)
ROUND SHAPE TERMINAL: ICTN2 - 4M OR TMEN2 - 4 (NICHIFU)
It consists of 2 types of cables.
Length L (m)
5
7
10
15
20
Motor Side
Driver Side
◇Motor Connection Cable L:10m、15m、20m
7.6
L
26.7
Model
CC05BLF
CC07BLF
CC10BLF
CC15BLF
CC20BLF
Motor Side
10
HOUSING: 350780 - 1(AMP)
ROUND SHAPE TERMINAL: ICTN2 - 3.5S OR TMEN2 - 3.5S (NICHIFU)
Driver Side
◇Signal Connection Cable
L
13.8
12
7
HOUSING: 5559 - 06P - 210 (MOLEX)
10
Motor Side
STICK TERMINAL: ICTNTC - 0.3 - 9.5 OR TMENTC - 0.3 - 9.5 (NICHIFU)
Driver Side
x Extension Cable (Sold Separately)
●Dimensions unit: mm
◇Motor Connection Cable
14.7
L
7.6
Signal Connection Cable
Motor Side
●Cable Set
It consists of 2 types of cables.
Connector Side
◇Signal Connection Cable
価
L
12
9.6
13.8
Length L (m)
1
2
3
5
7
10
15
20
HOUSING : 350780-1(AMP)
HOUSING : 350779-1(AMP)
7
13.8
Model
CC01BLFT
CC02BLFT
CC03BLFT
CC05BLFT
CC07BLFT
CC10BLFT
CC15BLFT
CC20BLFT
26.7
Motor Connection Cable
26.7
10
Motor Side
Connector Side
HOUSING : 5559-06P-210(MOLEX)
HOUSING : 5557-06R-210(MOLEX)
Note:
● Keep the cable length below 23m when connecting a cable included in the BLF Series and an extension cable.
c Flexible Extension Cable (Sold Separately)
●Dimensions unit: mm
◇Motor Connection Cable
L
7.6
14.7
Signal Connection Cable
Motor Side
Length L (m)
1
2
3
5
7
10
15
20
価
Connector Side
◇Signal Connection Cable
L
12
9.6
13.8
It consists of 2 types of cables.
HOUSING : 350780-1(AMP)
HOUSING: 350779-1(AMP)
6
13.8
●Cable Set
Model
CC01BLFRT
CC02BLFRT
CC03BLFRT
CC05BLFRT
CC07BLFRT
CC10BLFRT
CC15BLFRT
CC20BLFRT
26.7
Motor Connection Cable
26.7
8
Motor Side
HOUSING : 5559-06P-210(MOLEX)
Connector Side
HOUSING : 5557-06R-210(MOLEX)
Note:
● Keep the cable length below 23m when connecting a cable included in the BLF Series and an extension cable.
● Notes on Use of a Flexible Cable
q Do not allow the cable to bend at the
cable connector.
w Keep the bending radius to 60mm or
more.
e The motor cable and extension motor
cable are not a flexible cable. If the cable
is to be bent, bend it at the flexible motor
cable or flexible extension motor cable.
Flexible Extension Cable(Possible to bend)
Driver
Motor
Motor Cable (Affix the cable.)
11
Download