RoHS-Compliant Brushless DC Motor and Driver Package Motor: BLF Series Driver: 200 W/400 W The BLF Series brushless DC motor, which can achieve a maximum motor speed of 4000 r/min, is now available with high-output power of 200 W and 400 W. With the digital operator, digital setting and display are possible, offering a wide range of functions to meet your diverse needs. 왎Product Line Combination Type The combination type comes with the motor and its dedicated gearhead pre-assembled, which simplifies installation in equipment. Motors and gearheads are also available separately to facilitate changes or repairs. 쎲 Combination Type – Parallel Shaft Gearhead 쎲 Round Shaft Type Be sure to purchase connection cables. Be sure to purchase connection cables. Output Power Supply Power Voltage 200 W 400 W Output Power Model Gear Ratio Single-Phase 100-120 VAC BLF6200A-䡺 5, 10, 15, 20, 30, 50, 100, 200 200 W Single-Phase 200-240 VAC BLF6200C-䡺 5, 10, 15, 20, 30, 50, 100, 200 400 W Three-Phase 200-240 VAC BLF6200S-䡺 5, 10, 15, 20, 30, 50, 100, 200 Three-Phase 200-240 VAC BLF6400S-䡺 5, 10, 15, 20, 30, 50, 100, 200 Power Supply Voltage Model Single-Phase 100-120 VAC Single-Phase 200-240 VAC Three-Phase 200-240 VAC Three-Phase 200-240 VAC BLF6200A-A BLF6200C-A BLF6200S-A BLF6400S-A 쎲 Enter the gear ratio in the box (䡺) within the model name. 쎲 Pinion Shaft Type 쎲 Gearhead Be sure to purchase connection cables. Output Power 200 W 400 W 앳 Parallel Shaft Gearhead Power Supply Voltage Model Single-Phase 100-120 VAC Single-Phase 200-240 VAC Three-Phase 200-240 VAC Three-Phase 200-240 VAC BLF6200A-GFS BLF6200C-GFS BLF6200S-GFS BLF6400S-GFS 쎲 Connection Cables (Sold separately) 앳 Cable Set The cable set consists of two cables including a motor connection cable and a signal connection cable. Length 1m 2m 3m 5m 7m 10m 15m 20m Model CC01BLF CC02BLF CC03BLF CC05BLF CC07BLF CC10BLF CC15BLF CC20BLF Motor Connection Cable Output Power of Applicable Motor (Pinion Shaft Type) 200 W 400 W Gearhead Model Gear Ratio GFS6G䡺 5, 10, 15, 20, 30, 50, 100, 200 쎲 Enter the gear ratio in the box (䡺) within the model name. For details, refer to the BLF Series catalogue (30 W/60 W/120 W). 왎 Features 왎 System Configuration 왎 Timing Chart 왎 I/O Signal Circuits 왎 Operating Methods Signal Connection Cable 쎲 The BLF Series requires two dedicated cables, one for the motor and the other for signals, for connection between the motor and driver. Be sure to purchase the connection cable set. *Please take note that there are new product number code and accessories. Kindly refer to page 9 to 11 for more information. 1 왎Specifications 쎲 200 W, 400 W Motor: /Driver: Combination Type – Parallel Shaft Gearhead BLF6200A-䡺 BLF6200C-䡺 BLF6200S-䡺 BLF6400S-䡺 Round Shaft Type Rated Output Power (Continuous) W Rated Voltage VAC Permissible Voltage Range Rated Frequency Hz Power Source Permissible Frequency Range Rated Input Current A Maximum Input Current A Rated Torque N䡠m Starting Torque N䡠m Rated Speed r/min Speed Control Range r/min BLF6200A-A BLF6200C-A 200 Single-Phase 200-240 BLF6200S-A BLF6400S-A 400 Three-Phase 200-240 Model Round Shaft Type Permissible Load Inertia J⫻10-4 kg䡠m2 -4 Rotor Inertia J⫻10 kg䡠m 2 Speed Regulation✽ (When digital operator is used) Load Voltage Temperature Single-Phase 100-120 Three-Phase 200-240 ⫾10% 50/60 ⫾5% 4.7 8.8 2.8 5.1 0.65 1.15 1.7 3.4 2.8 5.6 1.3 1.8 3000 80앑4000 8.75 15 0.61 0.66 ⫾0.2% max. (0앑Rated torque, at rated speed, at rated voltage, at normal ambient temperature) ⫾0.2% max. (Rated voltage 앐10%, at rated speed, with no load, at normal ambient temperature) ⫾0.2% max. (0앑⫹50˚C, at rated speed, with no load, at rated voltage) ✽ Speed regulation values vary depending on the speed setting method. Settings from internal speed potentiometer, external speed potentiometer or external DC voltage; Load: ⫾0.5% max., Voltage: ⫾0.5% max., Temperature: ⫾0.5% max. 쎲 Enter the gear ratio in the box (䡺) within the model name. 쎲 The values for each specification apply to the motor only. 왎Common Specifications Item Specifications Speed Setting Method Select one of the following methods: 䡠 Set using the internal speed potentiometer 䡠 Set using the digital operator: Up to eight speeds 䡠 Set using an accessory external speed potentiometer: PAVR-20KZ (20 k⍀, 1/4 W) (sold separately) 䡠 Set using external DC voltage: 0앑5 VDC or 0앑10 VDC Acceleration/Deceleration Time (At 3000 r/min) 0.2앑15 sec. (factory setting: 0.5 sec.) Up to eight speeds using the digital operator Input Signal (In the remote mode) Photocoupler input mode Input resistance 3.3 k⍀ Internal power supply voltage: 14 VDC⫾10% Connectable external voltage: 24 VDC⫾10% (only for source logic) Source input (factory setting), Sink input/2-wire input mode (factory setting), or 3-wire input mode CW (START/STOP) input, CCW (RUN/BRAKE) input, STOP-MODE (CW/CCW) input, Speed data select, Alarm reset input, External error input Names in ( ) apply in the 3-wire input mode. Output Signal Open-collector output 4.5앑26.4 VDC, 10 mA max. (5앑10 mA for Speed output) Speed output (30 pulses/rotation), Alarm output1, Alarm output2 Protective Function✽ When the following are activated, the "Alarm" signal will be output and the motor will coast to a stop. (The motor will stop instantaneously in the event of an external error.) 䡠 Overload Protection: Activated when the motor load exceeds rated torque for a minimum of 5 seconds. 䡠 Overvoltage Protection: Activated when the voltage applied to the driver exceeds 120 VAC or 240 VAC by a minimum of 20%, a gravitational operation is performed or a load exceeding the permissible load inertia is driven. 䡠 Undervoltage Protection: Activated when the voltage applied to the driver falls below 100 VAC or 200 VAC by a minimum of 40%. 䡠 Missing Phase Protection: Activated when an error is detected in the signals received from the motor due to poor connection or breakage of the signal cable, etc. 䡠 Overspeed Protection: Activated when the speed of the motor shaft exceeds 4800 r/min. 䡠 Overcurrent Protection: Activated when an excessive current flows through the driver due to a ground fault, etc. 䡠 CPU Error, EEPROM Error, External Error, Operation Error Maximum Extension Distance Time Rating Motor/Driver Distance: 20.4 m (when a dedicated connection cable is used) Continuous ✽ With the BLF Series, the motor speed cannot be controlled in a gravitational operation or other application where the motor shaft is turned by the load. When a load exceeding the permissible load inertia is driven or a gravitational operation is performed, the overvoltage protective function will be activated and the motor will coast to a stop. 2 왎General Specifications Item Motor Insulation Resistance Dielectric Strength Temperature Rise Driver 100 M⍀ or more when 500 VDC megger is applied between the windings and the case after continuous operation under normal ambient temperature and humidity. 100 M⍀ or more when 500 VDC megger is applied between the power supply input terminal and the protective earth terminal, and between the power supply input terminal and the I/O terminal after continuous operation under normal ambient temperature and humidity. Sufficient to withstand 1.5 kV at 50 Hz applied between the windings and the case for 1 minute after continuous operation under normal ambient temperature and humidity. Sufficient to withstand 1.8 kV at 50 Hz applied between the power supply input terminal and the protective earth terminal for 1 minute, and 3 kV at 50 Hz applied between the power supply input terminal and the I/O terminal for 1 minute after continuous operation under normal ambient temperature and humidity. Temperature rise of the windings and the case are 50˚C or less, and 40˚C or less✽1 respectively measured by the thermocouple method after continuous operation under normal ambient temperature and humidity. Temperature rise of heat sink are 50˚C or less measured by the thermocouple method after continuous operation under normal ambient temperature and humidity. Ambient Temperature 0앑⫹50˚C (non-freezing) Ambient Humidity 85% or less (non-condensing) Altitude Atmosphere Operating Environment Up to 1000 m above sea level No corrosive gases or dust. Cannot be used in a radioactive area, magnetic field, vacuum or other special environment Not subject to continuous vibration or excessive impact In conformance with JIS C 60068-2-6, "Sine-Wave Vibration Test Method" Frequency range: 10앑55 Hz Pulsating amplitude: 0.15 mm Sweep direction: 3 directions (X, Y, Z) Number of sweeps: 20 times Vibration Ambient Temperature ✽2 Storage Condition ⫺25앑⫹70˚C (non-freezing) Ambient Humidity 85% or less (non-condensing) Altitude Up to 3000 m above sea level UL, CSA: class A (105˚C) EN: class E (120˚C) ⫺ IP65 (Excluding the mounting surface of the round shaft type and connectors) IP20 Insulation Class Degree of Protection ✽ 1 For round shaft types, please attach to the heat radiation plate (material: aluminum) of the following sizes to maintain a maximum motor case temperature of 90˚C. 䡺-A: 200⫻200 mm, 5 mm thick BLF6200䡵 BLF6400S-A: 250⫻250 mm, 6 mm thick 䡺) with the model name. 쎲 Enter A, C or S (power supply voltage) in the box (䡵 ✽ 2 The storage condition applies to a short period such as a period during transportation. Note: 쎲 Do not measure insulation resistance or perform the dielectric strength test while the motor and driver are connected. 왎Gearmotor – Torque Table of Combination Type 쎲 Combination Type – Parallel Shaft Gearhead 5 16 600 800 2.9 2.0 5.9 4.3 Gear Ratio 80 r/min Model Motor Speed 3000 r/min 4000 r/min 80앑3000 r/min 䡺-䡺 BLF6200䡵 4000 r/min 80앑3000 r/min BLF6400S-䡺 4000 r/min Unit ⫽ N䡠m 10 8 300 400 5.9 4.1 11.7 8.6 15 5.3 200 267 8.8 6.1 17.6 12.8 20 4 150 200 11.7 8.1 23.4 17.1 30 2.7 100 133 16.8 11.6 33.5 24.5 50 1.6 60 80 28 19.4 55.9 40.9 100 0.8 30 40 52.7 36.5 70 63 200 0.4 15 20 70 63 70 63 䡺) with the model name. 쎲 Enter A, C or S (power supply voltage) in the box (䡵 쎲 Enter the gear ratio in the box (䡺) within the model name. 쎲 A colored background ( ) indicates gear shaft rotation in the same direction as the motor shaft, while the others rotate in the opposite direction. 왎Permissible Overhung Load and Permissible Thrust Load 쎲 Combination Type – Parallel Shaft Gearhead Permissible Overhung Load Model Gear Ratio 5, 10, 15, 20 䡺-䡺 BLF6200䡵 BLF6400S-䡺 30, 50 100, 200 80앑3000 r/min 4000 r/min 80앑3000 r/min 4000 r/min 80앑3000 r/min 4000 r/min 10 mm from Shaft End N 20 mm from Shaft End N 550 500 1000 900 1400 1200 800 700 1250 1100 1700 1400 Permissible Thrust Load N 200 300 400 䡺) with the model name. 쎲 Enter A, C or S (power supply voltage) in the box (䡵 쎲 Enter the gear ratio in the box (䡺) within the model name. 쎲 Round Shaft Type Permissible Overhung Load Model 䡺-A BLF6200䡵 BLF6400S-A 10 mm from Shaft End N 20 mm from Shaft End N Permissible Thrust Load 197 221 The permissible thrust load shall be no greater than half the motor mass. 쎲 Enter A, C or S (power supply voltage) in the box (䡵 䡺) with the model name. 3 왎Permissible Load Inertia of Combination Type: J 쎲 Combination Type – Parallel Shaft Gearhead Gear Ratio 5 10 15 20 30 50 100 200 37.5 150 338 600 1350 3750 3750 3750 Model 䡺-䡺 BLF6200䡵 BLF6400S-䡺 Unit ⫽ ⫻10-4 kg䡠m2 䡺) with the model name. 쎲 Enter A, C or S (power supply voltage) in the box (䡵 쎲 Enter the gear ratio in the box (䡺) within the model name. 왎Speed – Torque Characteristics Continuous Duty Region: Continuous operation is possible in this region. Limited Duty Region: This region is used primarily when accelerating. When a load that exceeds the rated torque is applied continuously for approximately five seconds, overload protection is activated and the motor coasts to a stop. 䡺-䡺 / BLF6200䡵 䡺-A BLF6200䡵 BLF6400S-䡺/BLF6400S-A Starting Torque Starting Torque Torque [N·m] Torque [N·m] Rated Torque 1.8 1.15 Rated Torque Limited Duty Region 0.65 0.45 Limited Duty Region 1.3 0.95 Continuous Duty Region Continuous Duty Region 0 80 1000 2000 Speed [r/min] 3000 0 4000 80 1000 2000 Speed [r/min] 3000 쎲 The characteristics shown above are applicable for the motors only. 䡺) with the model name. 쎲 Enter A, C or S (power supply voltage) in the box (䡵 쎲 Enter the gear ratio in the box (䡺) within the model name. 왎Dimensions (Unit = mm) 쎲Mounting screws are included with the combination type. 쎲 200 W, 400 W 앳 Motor/Parallel Shaft Gearhead Motor Model Gearhead Model BLF6400S-□ BLFM6400-GFS GFS6G□ Mass: 5.4 kg (Including gearhead) 2 82 50⫾1 L 10 5 35⫾0.5 32 L CAD 5앑20 60 A652A 30, 50 72 A652B 100, 200 86 A652C 0 BLFM6200-GFS Gear Ratio 22⫺0.021(h7) 24.5 20⫾0.5 Model BLF6200A-□ BLF6200C-□ BLF6200S-□ M6⫻12 Deep 4⫻8.5 Thru A 15 42 䡺104 䡺110 9.5 25 104 A 0.5 120⫾ Sensor Cable 7, 400 mm Length Housing: 5557-06R-210 (MOLEX) Protective Earth Terminal M4 33 Motor Cable 8, 400 mm Length Housing: 350779-1 (AMP) 0 18.5 ⫺0.1 0 32⫾0.2 6⫺0.03 앳 Key and Key Slot (The key is included with the gearhead) 0 6 ⫺0.03 A⫺A 쎲 At the time of shipment, a parallel key is inserted on the gearhead's shaft. 쎲 Enter the gear ratio in the box (䡺) within the model name. 4 4000 앳 Round Shaft Type BLF6200A-A, BLF6200C-A, BLF6200S-A, BLF6400S-A 82 10 37⫾1 2 4⫻8.5 Thru 0 2 14⫺0.018(h7) 0 94⫺0.035(h7) 䡺104 Motor: BLFM6200-A, BLFM6400-A Mass: 2.4 kg A653 12 0⫾ 0.5 15 9.5 104 13 30 Sensor Cable 7, 400 mm Length Housing: 5557-06R-210 (MOLEX) Protective Earth Terminal M4 33 Housing: 350779-1 (AMP) Motor Cable 8, 400 mm Length 앳 Driver 앳 Digital Operator (Detached from the driver) BLFD200A2, BLFD200C2, BLFD200S2, BLFD400S2 Mass: 1.3 kg A654 106 130 13.4 17 max. 110 34 7 10.8 12.8 50 95 85 5 17 85 69 4⫻M3⫻4 Deep min. Slit 앳 Digital Operator Panel Cut-Out 4⫻3.5 5 Protective Earth Terminal M4 4⫻R2 max. 34⫾0.1 Protective Earth Terminal M4 19 12.3⫾0.2 2⫻4.5 Thru 8⫾0.2 19 69⫾0.1 9.8⫾0.2 쎲 Connection Cables (Sold separately) L: 1 to 7 m L Round Shape Terminal: ICTN2-3.5S or TMEN2-3.5S (NICHIFU) L: 1 to 20 m L 12 7 26.67 7.62 앳 Signal Connection Cable 13.8 앳 Motor Connection Cable 10 Housing: 5559-06P-210(MOLEX) Housing: 350780-1 (AMP) Stick Terminal: ICTNTC-0.3-9.5 or TMENTC-0.3-9.5 (NICHIFU) Round Shape Terminal (For Protective Earth): ICTN2-4M or TMEN2-4M (NICHIFU) 앳 Motor Connection Cable L: 10 to 20 m 26.67 L 7.62 10 Housing: 350780-1(AMP) Round Shape Terminal: ICTN2-3.5S or TMEN2-3.5S (NICHIFU) 5 왎Connection and Operation 쎲 Names and Functions of Driver Parts 앳 Digital Operator Mode Indicator LEDs Unit Indicator LEDs RUN LED Digital Operator RUN Key ALARM LED STOP Key Operation Keys Internal Speed Potentiometer I/O Signal Connection Terminals When the digital operator is detached Signal Cable Connection Terminals Protective Earth Terminal Protective Earth Terminal Power Supply Connection Terminals Motor Connection Terminals Digital Operator Connector CN1 POWER LED Remote-Control Connector CN2 Sink/Source-Input Select Switch Use this switch to select the sink mode or source mode for the input circuit. To use the digital operator remotely from the driver, connect the cable of the remote-control kit (sold separately) to this connector. External Voltage Select Switch To set speeds using external DC voltage, set this switch to 5 V or 10 V in accordance with the voltage supply used. 쎲 I/O Signal Terminal Name TH TH M0 M1 M2 VH VM VL C3 X0✽1 C0 C1 Signal Input X1✽2 X2✽2 X3✽2 X4 X5 Y1 Y2 Y0 C2 Output Signal Name N. C. N. C. M0 Input M1 Input M2 Input VH Input VM Input VL Input IN-COM1 EXT-ERROR Input IN-COM0 IN-COM0 2-Wire Mode: CW Input 3-Wire Mode: START/STOP Input 2-Wire Mode: CCW Input 3-Wire Mode: RUN/BRAKE Input 2-Wire Mode: STOP-MODE Input 3-Wire Mode: CW/CCW Input N. C. ALARM-RESET Input ALARM-OUT1 Output ALARM-OUT2 Output SPEED-OUT Output OUT-COM Function and Operation Do not connect any signal to this terminal. Do not connect any signal to this terminal. These signals are used to select operation data in multi-speed operation. One of up to eight preset speed data can be selected using the M0, M1 and M2 inputs. These signals are used to set speeds via an external speed potentiometer or external DC voltage. Input signal common (0 V) External error input (Normally closed) Input signal common Input signal common Clockwise direction/stop switch input signal Start/stop input signal Counterclockwise direction/stop switch input signal Run/instantaneous stop input signal This signal is input to select the motor stop action. Clockwise/counterclockwise direction input signal Do not connect any signal to this terminal. This signal is used to reset alarms. This signal is output upon generation of an alarm. (Normally closed) This signal is output upon actuation of the overload protective function or overload warning function. (Normally closed) 30 pulses are output per each rotation of the motor output shaft. Output signal common ✽ 1 Do not remove the short circuit bar if the EXT-ERROR input is not used. ✽ 2 The functions of the external-input signal terminals X1, X2 and X3 can be changed between the 2-wire input mode and 3-wire input mode. The functions under the 2-wire input mode are initially assigned to the terminals. 쎲 Digital Operator Indicator Display MNTR Function Running Alarm Monitor mode Details A green lamp stays lit while the motor is running. A red lamp turns on when an alarm occurs. The motor can be operated in this mode. The motor speed and load condition are displayed during motor operation. F/R Direction setting mode If the digital operator is used to operate the motor, set the motor direction in this mode. For: Clockwise direction, rEv: Counterclockwise direction LO/RE Digital operator/external-input signal mode In this mode, set whether to use the digital operator or external I/O signals to input the motor operation/stop signals. Lo: Digital operator, rE: External-input signals PRGM Data setting mode In this mode, set the data needed to operate the motor. Operation data (eight speeds and acceleration/deceleration times) Gear ratio setting/conveyor speed setting Input mode Overload warning function r/min m/min % Motor speed Conveyor speed Load factor✽ The speed of the motor or gearhead output shaft is displayed. An equivalent moving speed of the work on a conveyor or other transfer system is displayed. The actual load is displayed as a percentage of the rated torque being 100%. RUN ALARM Mode Display Unit ✽ A maximum error of approximately 20% may generate when the motor is operated at the rated speed under the rated load. 6 쎲 Connection Diagrams The figure below is a connection diagram for a configuration based on a three-phase 200-240 VAC supply voltage, with the sink/source-input select switch set to the sink side. 앳 Applicable Crimp Terminals 䡠 Power Supply Connection Terminal (M3.5): Round Terminal with Insulation Driver L L N N POWER 200-240 V 3~ Main Circuit ✽2 3.6 mm min. MOTOR R L1 U S L2 V T L3 W Motor Cable Connection 3.8 mm max. Motor 䡠 Protective Earth Terminal (M4): Round Terminal with Insulation Driver Ground Connection Speed setting via an external speed potentiometer or external DC voltage ✽4 VH Accessory PAVR-20KZ (20 k⍀ 1/4 W) VM VL Not to exceed the voltage selected by the external voltage select switch ✽3 HALL S. Vcc Signal Cable Connection B C GND 0V GND I/O Signal Connection ⫹14 V M0 M1 M2 IN-COM0 3.3 k⍀ M0 Internal Input Circuit M1 M2 C0 Y0 Y1 0V ⫹14 V I/O Signal Connection EXT-ERROR CW CCW STOP-MODE ALARM-RESET IN-COM0 Y2 C2 Output Circuit SPEED-OUT: 4.5 to 26.4 VDC, 5 to 10 mA SPEED-OUT 4.1 mm min. 4.8 mm max. A Speed Command Voltage External Voltage Select Switch Speed Selection Input Signals Motor Ground Connection✽1 Control Circuit 9.5 mm max. PE 6.2 mm max. after Crimping Single-Phase 100-120 VAC Single-Phase 200-240 VAC Circuit Breaker 7.2 mm max. Power Supply Connection Output Signals: 4.5 to 26.4 VDC, 10 mA or less 䡠 I/O Terminals Use the terminals specified below for connection using crimp terminals. Please note that the applicable crimp terminal will vary depending on the size of the wire. The following terminals can be used with wires of AWG26 to 22. [Manufacturer: Phoenix Contact] AI 0.25-6 Applicable cable size : AWG26 to 24 (0.14 to 0.2 mm2) AI 0.34-6 Applicable cable size : AWG22 (0.3 mm2) ALARM-OUT1 ALARM-OUT2 OUT-COM 3.3 k⍀ X0 Internal Input Circuit X1 X2 X3 X4 Sink/Source-Input Select Switch X5 C1 This indicates a shielded cable. 0V This indicates frame or enclosure. ✽ 1 The grounding method will vary depending on the length of the connection cable. When the connection cable is 7 m or shorter: Connect the protective earth terminal on the connection cable to the protective earth terminal on the driver. When the connection cable is 10 m or longer: Connect the protective earth terminal of the motor directly to the grounding point. ✽ 2 The main circuit is insulated to prevent electrical shock resulting from accidental contact by a hand, etc. ✽ 3 The signal cable connection terminals and the signal cable including the shielded cable comprise an ELV circuit, which is insulated from dangerous voltages only by means of basic insulation. Therefore, connect the shielded cable to the GND point specified in the connection diagram, instead of connecting it to a protective earth terminal. ✽ 4 The I/O signal connection terminals comprise a SELV circuit, which is insulated from dangerous voltages by means of double insulation or reinforced insulation. 왎List of Motor and Driver Combinations 쎲 Combination Type – Parallel Shaft Gearhead 쎲 Round Shaft Type The combination type comes with the motor and parallel shaft gearhead pre-assembled. Output Power 200 W 400 W Model BLF6200A-䡺 BLF6200C-䡺 BLF6200S-䡺 BLF6400S-䡺 Motor Model BLFM6200-GFS Gearhead Model Driver Model GFS6G䡺 BLFD200A2 BLFD200C2 BLFD200S2 BLFD400S2 BLFM6400-GFS Output Power 200 W 400 W Model BLF6200A-A BLF6200C-A BLF6200S-A BLF6400S-A Motor Model BLFM6200-A BLFM6400-A Driver Model BLFD200A2 BLFD200C2 BLFD200S2 BLFD400S2 쎲 Enter the gear ratio in the box (䡺) within the model name. 쎲 Pinion Shaft Type Output Power 200 W 400 W Model BLF6200A-GFS BLF6200C-GFS BLF6200S-GFS BLF6400S-GFS Motor Model BLFM6200-GFS BLFM6400-GFS Driver Model BLFD200A2 BLFD200C2 BLFD200S2 BLFD400S2 7 왎Accessories (Sold separately) 쎲 Remote-Control Kit The remote-control kit is useful if you want to detach the digital operator from the driver and install it on the frame of the equipment, etc., for remote operation. The kit includes an extension cable for digital operator/driver connection (2 or 5 m) and a rubber gasket. Model BLFHS-02 BLFHS-05 Example of Use Length: L (m) 2 5 Extension Cable Rubber Gasket Digital Operator This product is manufactured at a plant certified with the international standards ISO 9001 (for quality assurance) and ISO 14001 (for systems of environmental management). Specifications are subject to change without notice. This catalogue was published in September, 2007. SINGAPORE ORIENTAL MOTOR PTE LTD ORIENTAL MOTOR (MALAYSIA) SDN. BHD. 31 Kaki Bukit Road 3, #04-02/04 Headquarters & Kuala Lumpur Office TECHLINK, Singapore 417818 A-13-1, North Point Offices, Mid Valley City, TEL: +65-6745-7344 No.1 Medan Syed Putra Utara 59200 FAX: +65-6745-9405 Kuala Lumpur, Malaysia ORIENTAL MOTOR (THAILAND) CO., LTD. 900, 8th Floor Zone C, Tonson Tower, Ploenchit Road, Lumpini, Pathumwan, Bangkok 10330 Thailand TEL: +66-2-251-1871 FAX: +66-2-251-1872 TEL: +60-3-22875778 FAX: +60-3-22875528 Penang Office TEL: +60-4-6423788 FAX: +60-4-6425788 Customer Support Centre Japanese Customer Support Centre TEL: 1800-842-0280 (For Singapore) TEL: +65-6745-3008 1800-806161 (For Malaysia) Mailto: j-support@orientalmotor.com.sg +65-6842-0280 (For Other Countries) Mailto: support@orientalmotor.com.sg For more information please contact: This printed material uses ECF (Elementary Chlorine Free) paper and soyinks. This combination is environmentally friendly. Printed in Japan 07W 4.5K 2906T (B-001A) Information updated on 1st August 2008: We have a new product code system that includes motor, driver and connection cable(1/2/3m). ■Product Number Code BLF 5 12 A - 5 F - 1 ➀ ➁ ➂ ➃ ⑤ ➅ ➆ BLF:BLF Series 2:60mm 4:80mm 5:90mm 6:104mm (Geared Type: 110mm) 3:30W 6:60W 12:120W 20:200W 40 : 400W A:Single Phase 100~120VAC C: Single Phase 200~240VAC S: Three Phase 200~240VAC ① ② ③ ④ Series Motor Frame Size Output Power(W) Voltage ⑤ Gear Ratio or Shaft Type Number: 5 ~ 200 (8 types of ratio) A:Round Shaft Type S:Parallel Shaft F:Hollow Shaft Flat Gearhead ⑥ Gear Type ⑦ Provided Connection Cable 1: 1m, 2: 2m, 3: 3m ■Product Line ●Combination Type - Parallel Shaft Gearhead Output Power 30W 60W 120W 200W 400W Model BLF23A- SBLF23C- SBLF23S- SBLF46A- SBLF46C- SBLF46S- SBLF512A- SBLF512C- SBLF512S- SBLF620A-□SBLF620C-□SBLF620S-□SBLF640S-□S- Motor Model Gearhead Model BLFM230-GFS GFS2G BLFM460-GFS GFS4G BLFM5120-GFS GFS5G BLFM6200-GFS GFS6G□ BLFM6400-GFS Driver Model BLFD30A2 BLFD30C2 BLFD30S2 BLFD60A2 BLFD60C2 BLFD60S2 BLFD120A2 BLFD120C2 BLFD120S2 BLFD200A2 BLFD200C2 BLFD200S2 BLFD400S2 ● Enter the connection cable length 1(1m), 2(2m), 3(3m) within the model name. ●Combination Type - Hollow Shaft Type Gearhead Output Power 30W 60W 120W Model BLF23A- FBLF23C- FBLF23S- FBLF46A- FBLF46C- FBLF46S- FBLF512A- FBLF512C- FBLF512S- F- Motor Model Gearhead Model BLFM230-GFS GFS2G FR BLFM460-GFS GFS4G FR BLFM5120-GFS GFS5G FR Driver Model BLFD30A2 BLFD30C2 BLFD30S2 BLFD60A2 BLFD60C2 BLFD60S2 BLFD120A2 BLFD120C2 BLFD120S2 ● Enter the connection cable length 1(1m), 2(2m), 3(3m) within the model name. ●Round Shaft Type Output Power 30W 60W 120W 200W 400W Model BLF23A-ABLF23C-ABLF23S-ABLF46A-ABLF46C-ABLF46S-ABLF512A-ABLF512C-ABLF512S-ABLF620A-ABLF620C-ABLF620S-ABLF640S-A- Motor Model BLFM230-A BLFM460-A BLFM5120-A BLFM6200-A BLFM6400-A Driver Model BLFD30A2 BLFD30C2 BLFD30S2 BLFD60A2 BLFD60C2 BLFD60S2 BLFD120A2 BLFD120C2 BLFD120S2 BLFD200A2 BLFD200C2 BLFD200S2 BLFD400S2 ●Enter the connection cable length 1(1m), 2(2m), 3(3m) within the model name. 9 Accessories (Sold Separately) Connection Cables Extension Cables Flexible Extension Cables The BLF Series now comes with a cable of 1m, 2m or 3m for a connection between the motor and driver. When it is necessary to have a connection more than 5m between motor and driver, the motor cable or extension cable must be used. Use a flexible motor cable if the cable is constantly flexed during motor operation. ■ System Configuration ● Using a Connection Cable (Not using a cable included in the BLF Series) Please purchase this optional motor cable separately. zConnection Cable (sold separately) Length: 5m ~ 20m (5 types) Motor Connection Cable Signal Connection Cable Motor Driver ● Using an Extension Cable (Using a cable included in BLF Series) Please use the optional extension cable(sold separately) and connect with the provided cable. Use a flexible motor cable if the cable is constantly flexed during motor operation. xExtension Cable (sold separately) cFlexible Extension Cable (sold separately) Connection Cable (included) Length: 1m ~20m (8 types) Length: 1m, 2m, 3m Motor Cable Motor Cable Signal Cable Signal Cable Driver Motor Note: ●Keep the cable length below 23m when connecting a cable included in the BLF Series and an extension cable. z Connection Cables (Sold Separately) ●Dimensions unit: (mm) ◇Motor Connection Cable L:5m、7m L 7.6 ROUND SHAPE TERMINAL: ICTN2-3.5S OR TMEN2 - 3.5S (NICHIFU) Signal Connection Cable 26.7 Motor Connection Cable 10 ●Cable Set HOUSING: 350780 - 1(AMP) ROUND SHAPE TERMINAL: ICTN2 - 4M OR TMEN2 - 4 (NICHIFU) It consists of 2 types of cables. Length L (m) 5 7 10 15 20 Motor Side Driver Side ◇Motor Connection Cable L:10m、15m、20m 7.6 L 26.7 Model CC05BLF CC07BLF CC10BLF CC15BLF CC20BLF Motor Side 10 HOUSING: 350780 - 1(AMP) ROUND SHAPE TERMINAL: ICTN2 - 3.5S OR TMEN2 - 3.5S (NICHIFU) Driver Side ◇Signal Connection Cable L 13.8 12 7 HOUSING: 5559 - 06P - 210 (MOLEX) 10 Motor Side STICK TERMINAL: ICTNTC - 0.3 - 9.5 OR TMENTC - 0.3 - 9.5 (NICHIFU) Driver Side x Extension Cable (Sold Separately) ●Dimensions unit: mm ◇Motor Connection Cable 14.7 L 7.6 Signal Connection Cable Motor Side ●Cable Set It consists of 2 types of cables. Connector Side ◇Signal Connection Cable 価 L 12 9.6 13.8 Length L (m) 1 2 3 5 7 10 15 20 HOUSING : 350780-1(AMP) HOUSING : 350779-1(AMP) 7 13.8 Model CC01BLFT CC02BLFT CC03BLFT CC05BLFT CC07BLFT CC10BLFT CC15BLFT CC20BLFT 26.7 Motor Connection Cable 26.7 10 Motor Side Connector Side HOUSING : 5559-06P-210(MOLEX) HOUSING : 5557-06R-210(MOLEX) Note: ● Keep the cable length below 23m when connecting a cable included in the BLF Series and an extension cable. c Flexible Extension Cable (Sold Separately) ●Dimensions unit: mm ◇Motor Connection Cable L 7.6 14.7 Signal Connection Cable Motor Side Length L (m) 1 2 3 5 7 10 15 20 価 Connector Side ◇Signal Connection Cable L 12 9.6 13.8 It consists of 2 types of cables. HOUSING : 350780-1(AMP) HOUSING: 350779-1(AMP) 6 13.8 ●Cable Set Model CC01BLFRT CC02BLFRT CC03BLFRT CC05BLFRT CC07BLFRT CC10BLFRT CC15BLFRT CC20BLFRT 26.7 Motor Connection Cable 26.7 8 Motor Side HOUSING : 5559-06P-210(MOLEX) Connector Side HOUSING : 5557-06R-210(MOLEX) Note: ● Keep the cable length below 23m when connecting a cable included in the BLF Series and an extension cable. ● Notes on Use of a Flexible Cable q Do not allow the cable to bend at the cable connector. w Keep the bending radius to 60mm or more. e The motor cable and extension motor cable are not a flexible cable. If the cable is to be bent, bend it at the flexible motor cable or flexible extension motor cable. Flexible Extension Cable(Possible to bend) Driver Motor Motor Cable (Affix the cable.) 11