UPS Master VDC

advertisement
UPS
Master VDC
solutions
operation of several UPS and/or
flywheel modules (and a small
battery pack if required, for additional
reliability).
In
a
standard
configuration (1 x UPS and 1 x
flywheel), the runtime available is
more than sufficient to allow the UPS
to ride through short breaks in mains
power.
Flywheel VD C and VD C-XE
Thanks to their extremely high levels
of reliability, the VDC series of
flywheel energy storage systems
provide UPS with a secure and
reliable source of power that forms
the first line of defence against
interruptions to the mains power
supply; a fundamental defence for all
mission critical applications.
The VDC flywheel systems are fully
independent standalone devices.
They are designed for applications
such as data centres, hospitals and
Illustrative photo
industrial installations. They provide
a clean source of back up power by
Master VDC is a scaleable system comprised of
converting the kinetic energy stored within a
one or more UPS units and VDC or VDC –XE
rotating mass into electrical power using a built-in
flywheels. Master VDC is ideal for modern ECO
IGBT -based converter.
targeted data centres looking to achieve the lowest
VDC flywheel systems are available in two models,
possible PUE ratios and highest levels of reliability.
VDC standard and VDC -XE, which is able to
Master VDC UPS provide a number of advantages
provide superior performance for very short and
over more traditional battery equipped systems
very high power discharges.
including: up to 99% efficiency, a compact footprint
VDC series flywheels store kinetic energy in the
(up to 50% reduction), lower Total Cost of
form of a rotating mass (spinning at 36,000 RPM )
Ownership (TCO) and almost instantaneous
within a vacuum-sealed container. The VDC build
recharge times.
technology includes a rotor made from aerospaceA single flywheel module provides sufficient runtime
grade steel, a high speed permanent magnet motor/
for the start-up of a local standby generator to
generator and contact-free magnetic bearings that
power the UPS, which then provides a continuous
levitate and sustain the rotor during operation with
quality power supply.
no mechanical friction.
The entire system can be scaled for reliable power
These technical features allow VDC models to
(N+x) and increased runtime via the parallel
achieve very high levels of efficiency.
A2B, s.r.o., Horská 1, SK – 010 03 Žilina – Považský Chlmec
: +421 41 5000 490, : +421 41 5252 114, : a2b@a2b.sk, : www.a2b.sk
1/5
UPS
Master VDC
MODULARITY
Autonomy:
example with load at 100%:
30s, 1xVDC
1m, 2xVDC
Autonomy:
example with load at 50%:
25s, 1xVDC-XE
52s, 2xVDC-XE
REDUNDANCY (PARALLEL CONFIGURATION N+1)
Autonomy:
example with load at
50%:
52s, 2xVDC-XE
or 25s, 1xVDC-XE
BATTERY HARDENING
Autonomy:
example with load at 50%:
25s, 1xVDC-XE
Plus 10 minutes from an
additional battery set
DIMENSIONS
A2B, s.r.o., Horská 1, SK – 010 03 Žilina – Považský Chlmec
: +421 41 5000 490, : +421 41 5252 114, : a2b@a2b.sk, : www.a2b.sk
2/5
UPS
Master VDC
Technical specification
MASTER VDC: UPS MODULE SPECIFICATION
MHF
MHF
MHF
Models
100
120
160
Input
MHF
100
MHF
120
Nominal voltage
Frequency
Power factor
Harmonic current
distortion
Soft start
Frequency tolerance
Standard equipment
provided
Batteries
MHF
160
MHF
200
MHF
300
MHF
400
MHF
500
MHF
600
MHF
MHF
MHF
200
250
300
380-400-415 VAC 3-ph
45-65 Hz
>0,99
MHF
400
MHF
500
MHF
600
MHF
500
MHF
600
MHF
500
500
450
MHF
600
600
540
<3% THDi
0-100% in 120’’ (selectable)
±2% (selectable from ±1% to ±5% from front panel)
Back Feed protection, separable bypass line
MHF
100
MHF
120
MHF
160
MHF
200
Type
Ripple current
Recharge voltage
compensation
Output
Nominal power (kVA)
Active power (kW)
Number of phases
Nominal voltage
Static stability
Dynamic stability
Voltage distortion
Crest factor
Frequency stability on
battery
Frequency
Overload
Other features
Weight (kg)
Dimensions
(w x d x h) (mm)
Remote signals
Remote control
Communications
Ambient temperature
Relative humidity
Colour
Noise level at 1 m
IP rating
Smart Active efficiency
Standards
Classification in
accordance with
IEC 62040-3
MHF
250
MHF
MHF
250
300
Flywheels
Zero
MHF
400
-0,5 VxºC
MHF
100
100
90
MHF
120
120
108
MHF
160
160
144
MHF
200
200
180
MHF
MHF
MHF
250
300
400
250
300
400
225
270
360
3+N
380-400-415 VAC 3-ph+N
± 1%
± 5% in 10ms
<1% with linear load / <3% with non-linear load
3:1 lpeack/lrms
0,05%
50 or 60 Hz (selectable)
110% for 60’; 125% for 10’;150% for 1’
MHF
100
656
MHF
120
700
MHF
160
800
MHF
200
910
MHF
250
1000
MHF
MHF
MHF
MHF
300
400
500
600
1400
1700
2100
2400
1500x
2100x
800x850x1900
1000x850x1900
1000x1900
1000x1900
Dry contacts (configurable)
ESD and bypass (configurable)
Double RS232+dry contacts+2 slots for communications interface
0°C/+40ºC
<95% non-condensing
Dark grey RAL 7016
63-68 dBA
70-72dBA
70dBA 70dBA
IP20 (other on request)
Up to 98,5%
Safety IEC EN 62040-1-1 (Directive 2006/95/EC); EMC: EN 62040-2 (Directive
2004/108/EC)
(Voltage Frequency Independent) VFI-SS-111
A2B, s.r.o., Horská 1, SK – 010 03 Žilina – Považský Chlmec
: +421 41 5000 490, : +421 41 5252 114, : a2b@a2b.sk, : www.a2b.sk
3/5
UPS
Master VDC
MASTER VDC: FLYWHEEL MODULE SPECIFICATION
Models
VDC
Power
Maximum power
Max. energy
storage
Flywheel rotation
speed
Input
Recharge voltage
Recharge current
Efficiency
VDC-XE
VDC
215kW
VDC-XE
300kW
3000kWsek @ 100kW
4000kWsek @ 100kW
from 18500 to 36000 rpm
From 14500 to 36750 rpm
VDC
VDC-XE
400-600 VDC
15-50A (selectable)
99,2% at max. power
99,4% at max. power
Output
Discharge voltage
Voltage stability
Voltage ripple
VDC
VDC-XE
Other features
Ambient
temperature
Relative humidity
Colour
Noise level at 1 m
Dimensions
(w x d x h) (mm)
Weight (kg)
IP rate
VDC
Standards
400-520 VDC (adjustable)
±1%
≤2%
VDC-XE
-20°C/+40ºC
95% non-condensing
Dark grey RAL 7016
≤68dBA
762x762x1872
705
IP20
EMC EN 61000-6-4:2001; EMC EN 61000-6-2:2001; Safety: EN 60204-1; Directive
2004/108/EC; 98/37/EC
MASTER VDC: (FLYWHEEL ONLY) RUNTIME IN SECONDS
MHF
MHF
MHF
MHF
MHF
VDC 215kW
100
120
160
200
250
Number of
FLYWHEELS
1
2
3
4
5
Number of
FLYWHEELS
1
2
3
4
5
MHF
300
MHF
400
MHF
500
MHF
600
Power
100
120
160
200
250
300
400
500
600
100%
30
60
89
118
147
22
50
74
98
123
13
37
55
73
92
7
29
44
58
73
20
35
46
58
14
29
39
48
7
18
29
36
11
19
29
6
13
20
Power
100
120
160
200
250
300
400
500
600
75%
41
80
119
157
197
34
66
99
131
164
22
50
74
98
123
15
39
59
78
98
9
31
47
62
78
24
39
52
65
14
29
39
48
8
20
31
39
14
23
32
A2B, s.r.o., Horská 1, SK – 010 03 Žilina – Považský Chlmec
: +421 41 5000 490, : +421 41 5252 114, : a2b@a2b.sk, : www.a2b.sk
4/5
UPS
Master VDC
MHF
100
MHF
120
MHF
160
MHF
200
MHF
250
MHF
300
MHF
400
MHF
500
MHF
600
Power
100
120
160
200
250
300
400
500
600
50%
62
120
179
263
295
51
100
149
197
246
38
75
112
147
184
30
60
89
118
147
21
47
71
94
118
15
39
59
78
98
7
29
44
58
73
20
35
46
58
14
29
38
48
Power
100
120
160
200
250
300
400
500
600
25%
29
263
350
461
576
101
196
292
385
481
76
147
219
289
361
60
118
175
231
289
48
94
140
185
231
40
78
116
154
192
29
58
87
115
144
16
46
69
92
115
14
38
57
76
95
MHF
100
MHF
120
MHF
160
MHF
200
MHF
250
MHF
300
MHF
400
MHF
500
MHF
600
Power
100
120
160
200
250
300
400
500
600
100%
40
79
118
156
195
33
65
98
129
162
22
49
73
97
121
15
39
58
77
97
9
30
46
61
77
5
24
38
51
60
14
28
38
48
8
20
30
38
14
23
31
Power
100
120
160
200
250
300
400
500
600
75%
54
106
157
208
260
45
88
131
173
217
33
65
98
129
162
25
52
78
103
129
17
41
62
82
103
11
34
51
68
86
5
24
38
51
64
16
30
40
51
10
23
33
42
Power
100
120
160
200
250
300
400
500
600
50%
82
159
237
313
391
68
132
197
260
326
51
99
147
195
244
40
79
118
156
195
32
63
94
124
156
25
52
78
103
129
11
39
58
77
97
5
30
46
61
77
4
23
38
51
64
160
200
250
300
400
500
600
VDC 215kW
Number of
FLYWHEELS
1
2
3
4
5
Number of
FLYWHEELS
1
2
3
4
5
VDC-XE 300kW
Number of
FLYWHEELS
1
2
3
4
5
Number of
FLYWHEELS
1
2
3
4
5
Number of
FLYWHEELS
1
2
3
4
5
Number of
Power
100
120
FLYWHEELS
1
39
135
2
313
260
25%
3
465
387
4
614
511
5
767
639
All runtimes refer to UPS with 0.9pf and 94%
for 25% load. With no battery connected.
101
80
64
53
39
26
23
195
156
124
103
77
61
50
290
232
185
154
115
92
76
383
306
245
204
152
122
101
479
383
306
255
191
152
126
efficiency for 100%, 75% and 50% load, and 92% efficiency
A2B, s.r.o. reserves the right to change any specifications without prior notice (V012014)
A2B, s.r.o., Horská 1, SK – 010 03 Žilina – Považský Chlmec
: +421 41 5000 490, : +421 41 5252 114, : a2b@a2b.sk, : www.a2b.sk
5/5
Download