BATTERY –F FREE DC ENERGY STORAGE FOR UPS Yorba Linda CA (714) 386 -03800 Expect More From An Energy Storage Solution VYCON’s VYCON s VDC DC Flywheels VYCON’s VDC/XE flywheel system stores and delivers reliable li bl DC power utilizing tili i the th kinetic ki ti energy off high hi h speed flywheel. The flywheel can be deployed as the primary DC source or in parallel with traditional batteries in a Battery Hardening configuration. Tested ,Certified & Integrated by Eaton for application li ti on Powerware P 40 – 1100kVA UPS. DC Flywheel UPS A li ti / P h i gF t Application Purchasing Factors Green initiative Improved reliability D nott lik Do like b batteries tt i Floor space / footprint Structural / floor loading Reduced maintenance / budget Site /Application environment (HVAC) F Four (4) year Return R t O On Investment I t t (ROI) VYCON Key User Benefits vs Batteries Lowest cost of ownership • • • • • Low maintenance (No bearing changes) Lower life cycle cost vs VRLA battery High g efficiency y - 99.4% No cooling required Simple Installation & front access only required High reliability / predictability • • • • Continuously monitored Not discharge cycle limited Conservative design Air cooled VYCON Key User Benefits vs Batteries 20-year useful life • • Eliminate the 3 3-5 5 year lead acid battery change outs Parallel capability for future growth and or redundancy Green technology • • • Reduced Co2 Eliminates lead acid Reduces cooling / heating required by batteries High g power p density y • • Small footprint and top or bottom cable entry Free up space for revenue generating equipment or better utilization of available data center space VYCON Key User Benefits vs Batteries Space savings • Deploying flywheels to free up space for revenue generating g g equipment q p or better utilization of available data center space Eliminates or reduces installation or site concerns • limited space, floor loading, temperature control, hazardous material Mission Critical Protection for... Data Centers B Broadcast d t Healthcare/Hospitals Education Manufacturing Casinos/Gaming Power Q Quality y Applications pp Typical UPS system block diagram Long term AC alternate source Long-term Genset AC Automatic Transfer Switch Double Conversion UPS System ATS Rectifier Inverter AC/DC DC/AC 540 VDC 480 VAC Utility AC DC E Energy St Storage Critical AC output High Steel Flywheel Module g Speed, p y Permanent Magnet Motor-Generator Magnetic g Levitation VDC – Simplified p One Line Flywheel Module IGBT Power Converter Soft Start To UPS Battery Input DC Monitoring Motor Generator Controls Power Conversion Module Controller Control Panel Magnetic Levitation Controller Flywheel Cabinet Outline VDC and VDC-XE Max Power Rating: VDC : 215kW, 21 kW VDC-XE: 300kW, Foot Print: 6.25 sq ft Weight: 1520lbs Disconnect: DC Breaker included 73.7” 30” 30” Main Screen START button System Status STOP button System Mode Available Energy % No. of Discharge Events Current date and time Submenu buttons (appear on all screens) Silence Horn button Battery y Free Systems y 40 – 160-KVA 30 Sq Ft 14 Battery y Free Systems y 225 – 1100-KVA 30 Sq Ft 15 Flywheel Technology Third Generation Design – VYCON • • • • • High speed - 36000 RPM No mechanical bearings Ai cooled Air l d Small steel alloy flywheel mass (120lbs) Annual service requirement • 15 mins. • no down time • • High power density Full recovery from drop out event Configurations VYCON DC Flywheel - Battery Free UPS System UPS Back up Generator Automatic Transfer Switch Critical Load ATS Utility 208 – 600V AC VYCON Flywheel DC Energy Storage DC Bus Configurations VYCON DC Flywheel + Battery Hardening UPS Back up Generator Automatic Transfer Switch Critical Load ATS DC Bus + - Utility + - 208 – 600V AC + - + - VYCON Flywheel DC Energy Storage Vycon VDC Energy Storage System Battery Hardening Battery Hardening Battery “Whiplash” Prevented Float Voltage UPS S DC Bus V Voltage (dc)) Grid Disturbance w/ flywheel Nearly 99% of all voltage sags and outages last less than 8 seconds Gen Coup de fouet = Whiplash 98% of disturbances < 10 sec. 0 10 20 Time (Seconds) Flywheel provides voltage support eliminating battery whiplash Increasing battery life, Improving UPS reliability & Reducing service Vycon VDC Energy Storage System Typical ROI Calculations VYCON… Expect more from your energy storage company Reliable, efficient high power density energy storage for UPS, VFDs, energy recycling and regeneration Proven reliability with over 2,500,000 discharge and recharge events on our installed systems world wide VYCON has h 5 major j patents t t for f the th design of the flywheel system Most recognized / awarded UPS flywheel manufacture in 2009 2009 Green Excellence Award in Product Innovation 2009 Most Sustainable Product Vycon VDC Energy Storage System Questions http://www.vyconenergy.com/ Yorba Linda CA (714) 386 -03800