Constant current LED Drivers For outdoor use LGU-50C Series, 50 Watt FEATURES: Constant current output Universal AC input: 90-305VAC Active power factor correction Short circuit, over voltage, over temperature protections Designed to worldwide safety standards for lighting Cooling by free air convection 3 year warranty Model Input voltage (Vac) Output current (mA) Output voltage (Vdc) Output power (W) Min. Max. LGU50-C350 350 86 143 50.5 LGU50-C450 450 67 111 50 700 43 71 50 1050 29 48 50.4 LGU50-C1400 1400 21 36 50.4 LGU50-C2100 2100 14 24 50.4 LGU50-C700 LGU50-C1050 90-305 Note: 1. Add suffix for dimming option, “D” (0~10V), “P” (PWM), “T” (Timer); 2. Add suffix for package option, blank(default), “W” or “L”. See mechanical specifications. ELECTRICAL Input Parameters Symbols Test Conditions / Comment Min. Typ. Max. Units Input voltage Vin -- 90 -- 305 Vac Input frequency Fline -- 47 -- 63 Hz Input current Iin Full load, Vin = 230Vac -- 0.26 -- A Inrush current Iinrush Cold start, Vin = 230Vac -- 35 -- A Power factor PF 70%~100% load, Vin = 230Vac -- 0.96 -- PF η Full voltage, full load -- 90 -- % Efficiency www.pairuigroup.com Page: 1 / 4 Date: 02/21/2014 Constant current LED Drivers For outdoor use LGU-50C Series, 50 Watt ELECTRICAL Output Parameters Symbols Test Conditions / Comment Min. Typ. Max. Units -- -- -- 5 -- % LGU50-C350 -- -- 163 V LGU50-C450 -- -- 130 V LGU50-C700 -- -- 83 V LGU50-C1050 -- -- 56 V LGU50-C1400 -- -- 41 V LGU50-C2100 -- -- 29 V Output current accuracy No load out voltage VNO-Load Line regulation Iout-line Vin from 90Vac to 305Vac -- -- 1 % Load regulation Iout-load Vout from min. to max. -- -- 3 % Iover-shoot Turning power on -- -- 10 % Ton_delay Cold start, power on -- -- 2 S -- -- -- 20 -- % Output Current overshoot Turn-on delay time Ripple Protection Over voltage 115~150% rated output voltage. In latch mode, the power supply shall return to normal operation only after the power is turned on again. Short circuit In hiccup mode, it will recover automatically after fault conditions are removed. Over temperature Typ. 110 ℃ Environment Storage Ambient operating temperature Maximum case temperature Operating relative humidity MTBF Dimension(LxWxH) www.pairuigroup.com Tstorage Humidity: 5% RH to 95% RH -40 -- +85 ℃ Ta Startup at rated voltage -35 -- +70 ℃ Tc Hot-spot on case -- -- +80 ℃ Ha Non condensing 10 -- 95 % -- 400 -- kHrs TMTBF Full load, 220Vac input, ℃ 25 ambient temperature L: 193x43.5x34.5mm/W: 127x67.5x36.5mm Page: 2 / 4 Date: 02/21/2014 Constant current LED Drivers For outdoor use LGU-50C Series, 50 Watt ELECTRICAL Safety / EMC Safety standards UL8750, UL935, UL1012, UL1310 CLASS 2, EN61347-1, EN61347-2-13 EMC EN55015, FCC Part 15 Class B, EN61000-3-2, EN61000-3-3, EN61000-4-2,3,4,6,8,11, EN61547 Notes: Unless otherwise specified, all the above parameters are measured at ambient temperature of 25 Vin = 90Vac to 305Vac. ℃ and MECHANICAL PACKAGE TYPE “L” Unit: mm PACKAGE TYPE “W” Unit: mm www.pairuigroup.com Page: 3 / 4 Date: 02/21/2014 Constant current LED Drivers For outdoor use LGU-50C Series, 50 Watt DERATING CURVE STATIC CHARACTERISTIC CURVE 100 90 80 Load ) % 70 ( 60 50 40 30 - 30 - 15 0 15 30 40 50 60 70 90 Temperature(℃) www.pairuigroup.com 120 150 180 210 240 270 300 330 Input voltage ( Vac ) Page: 4 / 4 Date: 02/21/2014