FLOW HUMIDITY Kele Provides Solutions for Air and Fluid Movement, Measurement, and Control. 220B | p. 291 NFP Series | p. 310 626600A | p. 320 FLOW KOAMS | p. 273 Recordall | p. 337 Disc Meter EE65 | p. 282 FLOW Products manufactured in the United States Products that are new to the catalog DTFXL Series | p. 301 FLOW FT2A Series | p. 286 DPFS Series | p. 280 kele.com MODEL/SERIESPAGE Air Flow KOAMS Series — Kele Outdoor Airflow Measuring System . . . . . . . . . . . . . . KMS Series — Airflow Measuring Station . . . . . . . . . . . . . . . . . . . . . . . . . . . . KIP Series — Fan Inlet Airflow Measuring Probe. . . . . . . . . . . . . . . . . . . . . . . 160 Series — Stainless Steel Pitot Tubes. . . . . . . . . . . . . . . . . . . . . . . . . . . . . FXP Series — Differential Pressure Air Velocity Sensors. . . . . . . . . . . . . . . . . AMP Series — Ampliflow Air Velocity Sensor. . . . . . . . . . . . . . . . . . . . . . . . . . DPFS Series — Low-Cost Differential Pressure Flow Sensor . . . . . . . . . . . . . SSS-1000 Series — Differential Pressure Flow Sensors. . . . . . . . . . . . . . . . . EE65 and EE66 Series — Air Velocity Transmitters. . . . . . . . . . . . . . . . . . . . . AVS-200 — Air Velocity Transmitter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A2G-20 Series — Air Flow. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . FE-1000 Series — Insertion Type Airflow Sensing Element. . . . . . . . . . . . . . . FE-1050 Series — Fan Inlet Airflow Sensing Element. . . . . . . . . . . . . . . . . . . 273 275 276 277 278 279 280 281 282 283 284 341 342 Gas Flow FT2A Series — Thermal Mass Flow Meter. . . . . . . . . . . . . . . . . . . . . . . . . . . . 286 Liquid Flow SDI Series — Flow Sensor with Integral Flow Transmitter . . . . . . . . . . . . . . . . 200 Series Overview — Flow Sensors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 220B, 220SS — Brass & Stainless Steel Flow Sensors. . . . . . . . . . . . . . . . . . 225B, 226B, 226SS Series — Hot Tap Flow Sensors . . . . . . . . . . . . . . . . . . . 228B, 228C, 228SS — Tee-Mounted Flow Sensors. . . . . . . . . . . . . . . . . . . . . 250B — Tee Mounted Flow Sensor. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 228PV Series — PVC Tee Flow Sensors. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 310 Series — Programmable Analog Flow Transmitter . . . . . . . . . . . . . . . . . . UFT-1 Series — Universal Flow Transmitter. . . . . . . . . . . . . . . . . . . . . . . . . . . 3000, 3050 Series — Flow and Energy Monitor. . . . . . . . . . . . . . . . . . . . . . . . DTFXL Series — Ultrasonic Flowmeter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . M-2000 Series — Magnetic Flow Meter. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2200, 3100 Series — Fixed and Retractable Insertion Vortex Flow Meters . . . V-BAR 700 — Insertion Vortex Flow Meter. . . . . . . . . . . . . . . . . . . . . . . . . . . . NFP Series — Target Flow Meter. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 340 Series — BTU Transmitter. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 380 Series — BTU Meter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . DE/DB Series — Ultrasonic Energy Meter, Flow Meter . . . . . . . . . . . . . . . . . . 626600A — Paddle Flow Switch. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . FS1-6 — Flow Switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . F61 Series — Flow Switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . EDC Condensate Pumps — COU, LIM, JAG, and PAN Models. . . . . . . . . . . DXN Series — Portable Ultrasonic Flow and Energy Meter. . . . . . . . . . . . . . . IOG Series — Industrial Oval Gear Meter . . . . . . . . . . . . . . . . . . . . . . . . . . . . RCDL Compound Series — Recordall® Compound Series Meter . . . . . . . . . RCDL Nutating Disc — Recordall® Nutating Disc Meters . . . . . . . . . . . . . . . . RCDL Turbo Series — Recordall® Turbo Series Meters . . . . . . . . . . . . . . . . . 289 290 291 292 293 294 295 296 297 299 301 303 307 309 310 312 314 316 320 322 324 326 327 331 335 337 339 NEW! FLOW KELE OUTDOOR AIRFLOW MEASURING SYSTEM KOAMS SERIES DESCRIPTION The Kele KOAMS Series outdoor airflow measuring system consists of multiple airflow elements, factory mounted and pre-piped in a casing designed for flanged connection to ductwork, control dampers, louvers, etc. An optional inlet bell is available for plenum applications. The integral signal processor utilizes current state-of-the-art digital microprocessor technology with unequaled 24-bit A/D and 12-bit D/A signal conversion resolution and has twelve-point linearization capability. The KOAMS is capable of measuring down to 100 fpm and providing full scale operating ranges as low as 693 fpm. The signal processor accepts a temperature input signal for air density compensation for standard (scfm) or actual (acfm) airflow calculations. 6 KOAMS with Inlet Bell FEATURES • • • • • • • • • Full scale spans as low as 693 fpm (3.52 m/s) velocity Excellent AD/DA resolution: 24-bit A/D and 12 bit D/A Twelve point linearization and four point flow correction Large back lit LCD for configuration and local indication of the measured process Auto zeroing function Temperature compensation for air density correction NEMA 4 rated enclosure Modbus communication Certified LonWorks® or BACnet MS/TP® communication option FLOW • Accuracy of ±0.5% through the velocity range of 200 to 1,200 fpm and ±5% accuracy at 100 FPM • Multiple total and static pressure sensing ports to comply with ASHRAE Standard 111 for duct traversing • Not affected by condensation or moisture • Aerodynamically designed to resist fouling by airborne particulates • Factory mounted and pre-piped in a flanged duct section (casing) • Optional inlet bell for plenum applications • Airflow station can be operated in humidity ranges of 0 to 100% with no effect on the station SPECIFICATIONS Supply Voltage Supply VA 20 to 28 VAC/VDC Standard processor: 4.6 VA at 24 VAC, 2.7 VA at 24 VDC Full-option processor: 6 VA at 24 VAC/VDC Accuracy Within ±0.5% of actual flow through the range of 200 to 1,200 fpm, and ±5% at 100 fpm velocity, when installed in accordance with publlished recommendations Operating TemperatureProcessor: 32° to 122°F (0° to 50°C) Station: up to 350°F (177°C) continuous operation Operating Humidity Processor: 0 to 95% RH, noncondensing Station: 0 to 100% RH Velocity Range 100 to 2,800 fpm March 2014 Materials Of Construction Elements: 6063-T5 anodized aluminum Casing: 16 ga. G90 galvanized steel (other materials available special order) Enclosure Rating NEMA 4X with proper connectors Dimensions Processor housing 6.7"H x 4.7"W x 2.7"D (16.9 x 11.9 x 6.9 cm) Analog Output Jumper selectable 0-5 VDC, 0-10 VDC (1KΩ minimum), or 4-20 mA (500Ω maximum) Digital Outputs Optional high/low alarm, two single (one Form C) dry contact Contact Rating 5A at 30 VAC/VDC, 10A at 120 VAC resistive load Communication LonWorks®, BACnet MS/TP®, Modbus WE MAKE IT EASY. kele.com 888-397-5353 USA 273 FLOW NEW! KELE OUTDOOR AIRFLOW MEASURING SYSTEM KOAMS SERIES SIGNAL PROCESSOR FIELD CONNECTIONS 6 ORDERING INFORMATION DIMENSIONS FLOW MODEL DESCRIPTION KOAMS Outdoor airflow measuring system CASING WIDTH (inches, minimum increments of 1/4") CASING HEIGHT (inches, minimum increments of 1/4") CASING LENGTH (5", 8", 12"; custom lengths available) “W” “L” PROBE DIRECTION “F” Static pressure port 2 Casing height SIGNAL PROCESSOR MOUNTING LOCATION 3 Flow Total pressure port Remote OUTPUT “H” 1 4-20 mA 2 0-5 VDC 3 0-10 VDC 2 TEMPERATURE TRANSMITTER OPTIONS Flanged Stations for Ducted Applications 1 Inlet bell (not available w/5˚ casing) 3 High/Lo alarm 4 LonWorks Communication 5 BACnet MS/TP Communication 6 Modbus Communication 7 Optional 0.1% F.S. Accuracy “W” “L” “F” Static pressure port KOAMS - 20 - 30 - 12 - 2 - 3 - 1 - 2 - 1 Flow Example: KOAMS-20-30-12-2-3-1-2-1 20" x 30" station with 12'' casing length, 4-20 mA output, and inlet bell “H” Total pressure port 4" Stations with Optional Inlet Bell for Plenum Applications Note: Dimension "F"= 1-1/2' (stations 8'-72") or 2' (stations > 72") 274 888-397-5353 USA kele.com KOAMS-TT RELATED PRODUCTS Replacement outside air temperature transmitter (-30° to 130°F) WHEN YOU NEED IT RIGHT, RIGHT NOW, CALL KELE. March 2014 NEW! FLOW AIRFLOW MEASURING STATION KMS SERIES DESCRIPTION The Kele KMS Series airflow measuring stations utilize multiple averaging sensors for static pressure measurements and a bullet-nose probe for total pressure. The sensors are distributed across the flow stream to conform to the industry standard rules for equal-area averaging (the standard pitot traverse). The standard unit includes a 16-gauge galvanized casing with flanged duct connection, 3/8'' hexagon-celled aluminum flow straightening vanes, and internal copper sensors constructed to ASTM B88. Instrument connections are 1/2'' FNPT. Other configurations are available on request. APPLICATION When utilized with a differential pressure transmitter, the KMS Series provides an accurate, repeatable airflow signal for building automation and HVAC applications. Air velocity may be determined by the formula: Velocity (fpm) = 4004√∆P, where ∆P is differential pressure in "W.C. Then, flow rate may be determined by the formula: CFM = AV, where A is the effective area of the flow measuring station in square feet, and V is the velocity obtained above. The proper range for a differential pressure transmitter to use with the KMS Series airflow measuring station may be determined by the formula: ∆P = (Max Velocity/4004)2. KMS Front and Back 6 SPECIFICATIONS 1/2" FNPT HI/LO pressure pickups, factory-mounted on the long side dimension when station is rectangular Accuracy ±2% within design flow range Minimum Velocity 1000 fpm (305 mpm) Maximum Velocity 6000 fpm (1830 mpm) Mounting Duct flanges standard Media Compatibility Clean HVAC duct air Media Temperature Range 400°F (204°C) maximum Maximum Pressure 6" W.C. maximum duct static Pressure Drop <0.13" W.C. @ 2000 fpm Materials Of Construction Casing: 16-gauge galvanized sheet steel; pickup sensors: rigid copper (hard drawn to ANSI H23.1 and ASTM B88 standards); internal fittings: copper (ANSI B-16.22); straightening vanes: 3/8" aluminum hexagon cell Dimensions Casing depth 12" (30.5 cm); H x W dimensions made-to-order Warranty 1 year FLOW Connections ORDERING INFORMATION MODEL KMS KMS DESCRIPTION Airflow measuring station SHAPE 811 Round with flanges 911 Rectangular with flanges DIMENSIONS W x H Diameter or width x height (inches) 911 48 x 24 Example: KMS-911-48 x 24 Rectangular airflow station with 16-gauge galvanized casing, 3/8'' straightening vanes, and copper probes 48'' wide x 24'' high Note: Standard location for flow connections is on the "long" dimensions side of a rectangular station. Stations can be rotated. If connections must be located on the "short" side, specify it on the order; a cost adder applies. KMS-PAK-B March 2014 ACCESSORIES 1/2" FNPT to 1/4" OD tubing barb fitting WE MAKE IT EASY. kele.com 888-397-5353 USA 275 FLOW NEW! FAN INLET AIRFLOW MEASURING PROBE KIP SERIES DESCRIPTION The Kele KIP Series fan inlet airflow measuring probe provides a reliable and economical means to measure airflow at fan inlets. Similar to airflow stations, the probe measures velocity pressure with multiple averaging pickups for total and static pressure. Rugged, lightweight, and easy to install, it is used with industry-standard differential pressure transmitters, gauges, or manometers. KIP Series probes install easily at the fan inlet and do not require straight duct runs. They are particularly applicable for jobs where fitting a flow measuring station is difficult or impossible. 6 FEATURES • Easy and quick to install • Accurate and repeatable • Economical • Lightweight and rugged • No straight duct runs required • High velocity, high differential • Standard airflow calculations For fan inlet depth > 3.5" For fan inlet depth 0.5" to 3.5" FIGURE 1. FAN INLET FLOW SPECIFICATIONS Connections 3/16" barbs for 1/4" OD poly tubing Accuracy ±2% within design flow range Minimum Velocity 400 fpm (122 mpm) Maximum Velocity 12,000 fpm (3658 mpm) Mounting Drill/screw on fan inlet Media Compatibility Clean HVAC duct air Media Temperature Range 400°F (204°C) maximum Materials Of Construction Aluminum with anodized finish Dimensions Made-to-order Warranty 1 year 1 2 Distance varies with inlet diameter 2 Inlet Flow View Y Mount ultraprobe in smallest diameter Isometric View Dimension Y is the smallest fan inlet diameter. The probes will be built for proper spacing using this dimension, which is required for ordering. APPLICATION The fan inlet diameter (dimension Y) shown in Figure 1, must be correctly determined and specified. Each set of probes is made to order and cannot be returned for credit if the dimensions are incorrectly specified. If the fan inlet depth is 3.5" (8.9 cm) or greater, order the KIP-Y-3.5. Each KIP Series probe will have both static (low) and total (high) pressure pickup barbs. “Tee” the high-pressure pickups together and the low pickups together. If the fan inlet depth is less than 3.5" (8.9 cm), order the KIPY-.5. One KIP Series probe will have a single static (low) pressure pickup barb, and the other probe will have a single total (high) pressure pickup barb. Determining the differential (velocity) pressure for a KIP Series probe is the same as for a pitot tube or flow measuring station (see KMS Series catalog page for formulas). ORDERING INFORMATION Model KIP-Y-.5 KIP-Y-3.5 Description Probe set for fan inlet depth 0.5" to 3.5" (specify Y; = inlet diameter range 6" to 96" (15 to 244 cm) Probe set for fan inlet depth > 3.5" (specify Y; = inlet diameter range 6" to 96" (15 to 244 cm) Note: One KIP includes a pair of pickup probes for measuring airflow at a fan inlet. For dual inlet fans, two KIPs must be ordered. CX, RX, XLdp Series M264 Series T-101 276 888-397-5353 USA kele.com RELATED PRODUCTS Ashcroft differential pressure transmitters Setra differential pressure transmitter 1/4" OD black poly tubing, 1 coil, 250 ft (76 m) WHEN YOU NEED IT RIGHT, RIGHT NOW, CALL KELE. PAGE 1014 901 March 2014 NEW! FLOW STAINLESS STEEL PITOT TUBES 160 SERIES DESCRIPTION The Dwyer 160 Series stainless steel pitot tubes are designed for use with differential pressure transmitters, manometers, or air velocity gauges to measure air flow in ducts. See Measuring Air Flow in the Technical Reference Section for complete application information. The 160 Series is designed per ASME and meets AMCA and ASHRAE standards. Insertion depth is stamped on the side of the pitot tubes, and the static pressure port is parallel to the sensing tube to allow easy alignment with air flow. A Model A-158 split flange mounting kit allows for simple, leak-free mounting of the 160 Series. 160-12 tube and A-158 mounting flange FEATURES • • • • 6 • Air velocity calculator, flow charts, and instructions included • 1/4" connections for 3/8" OD tubing • Handy A-158 split flange for duct mounting • One year warranty 304 stainless steel construction ASME design Accurate even with up to 15° misalignment Insertion depth markings stamped on tube DIMENSIONS 8.0 (20.32), 12.0 (30.48), 18.0 (45.72), 24.0 (60.96), 0.5 (1.27) 36.0 (91.44) or 48.0 (121.92) FLOW in (cm) Total pressure connection 0.31 (0.79) 5.0 (12.7) 2.66 (6.75) 0.25 (Fits 3/8'' OD (0.64) poly tubing, Model T-110) Static pressure 8 - 0.040 diameter holes (0.10) equally spaced Total pressure 0.125 diameter hole (0.32) (face into air flow) 3.63 (9.21) Static pressure connection 0.25 (Fits 3/8'' OD (0.64) poly tubing, Model T-110) Note: See Measuring Airflow in the Technical Reference section for application of 160 Series pilot tubes for flow measurement. ORDERING INFORMATION MODEL DESCRIPTION 160 Stainless steel pitot tube LENGTH XX Length (inches) - 8, 12, 18, 24, 36, 48 160 March 2014 18 Example: 160-18 Pitot tube with 18" insertion length CX, RX, XLdp Series M264 Series T-110 RELATED PRODUCTS Ashcroft differential pressure transmitters Setra differential pressure transmitter 3/8" OD black poly tubing, 1 coil, 250 ft (76 m) A-158 ACCESSORIES 160 Series pitot tube mounting flange (required for duct mount) WE MAKE IT EASY. PAGE 1014 901 kele.com 888-397-5353 USA 277 FLOW NEW! DIFFERENTIAL PRESSURE AIR VELOCITY SENSORS FXP SERIES DESCRIPTION The Kele FXP Series probe is a differential air pressure sensor designed to measure air velocities in HVAC ductwork. It uses multiple sensing points to measure total and static pressures and incorporates a unique design to amplify the differential pressure by approximately 2.5 times for accurate measurement of air velocities down to 200 fpm. It is easy to install and cost effective. FEATURES 6 • • • • • • Multiple sensing points for greater accuracy Easy installation Chamfered sensing points for consistent readings 2% accuracy 2.5X signal amplification Accepts 1/4" OD tubing FXP -10 PERFORMANCE CHART FLOW INSTALLATION Check that the FXP probe size corresponds with the duct or terminal where it is installed. The FXP probe is mounted in the duct by drilling a 1" diameter hole. Check that the air flow direction in the duct corresponds with the arrow on the FXP probe. For round ducts, install the FXP probe diagonally in the duct for best results. This equalizes both horizontal and vertical irregular air approach. FXP Calibration Curve fpm Air Velocity (fpm) 10.000 1.000 SIZING THE PRESSURE TRANSMITTER • • • • • CFM- Cubic feet per minute (customer furnished) A- Area square feet (customer furnished) V- Velocity feet per minute (customer furnished) ∆P- Differential pressure in WC" Use formula B to calculate the ∆P for transmitter V(FPM) = CFM A ∆P = V Kv V = Kv * ΔP Formula A Formula B FXP Calibration Chart Size Kv Size Kv Size 4" 2225 7" 2450 12" 5" 2325 8" 2480 14" 6" 2400 10" 2440 16" 18" and up 2550 278 888-397-5353 USA 2 kele.com Kv 2500 2525 2550 100 0.001 0.010 0.100 Differential Pressure ("w.g.) Fpm=2213 ∆P 1.000 mps=11242 10.000 ∆P ORDERING INFORMATION MODEL DESCRIPTION FXP FXP air velocity sensor WIDTH XX Duct width (up to 48") RELATED PRODUCTS PAGE T-101 1/4" OD black poly tubing, 1 coil, 250 ft (76 m) 901 M264 Series Setra differential pressure transmitter 1014 CX, RX, XLdp Series Ashcroft differential pressure transmitters WHEN YOU NEED IT RIGHT, RIGHT NOW, CALL KELE. March 2014 NEW! FLOW AMPLIFLOW AIR VELOCITY SENSOR AMP SERIES DESCRIPTION The Kele AMP Series ampliflow air velocity sensor is designed to measure air flow velocity in HVAC duct systems. The design of the AMP Series allows it to amplify the velocity pressure by a factor of three, which, in turn, allows low air flow velocities to be accurately measured. Sensing holes along the length of the tube yield an average velocity pressure reading for greater accuracy. The simple design of the AMP Series allows quick, easy installation in new or existing ductwork. AMP-18 FEATURES Multipoint readings for average velocity pressure Simple installation Rugged, extruded aluminum construction Double taps allow field check connections Three-to-one ratio pressure signals Adaptable to round, square, or oval ducts 1/4" barbs for 3/8" OD tubing One year warranty 6 PERFORMANCE AMPLIFLOW SENSOR CALIBRATION CURVE 5000 4000 3000 2000 INSTALLATION Mount the AMP Series at least three (10 is ideal) duct diameters downstream of coils, dampers, or elbows, and through the width of the duct for best results. Cut a hole 0.75"H x 0.88"W (1.9 x 2.3 cm) in the duct. Drill holes in the opposite side of the duct to allow the field pressure taps to protrude through the duct. Remove the rubber caps from the field pressure taps and insert the AMP Series into the duct so that the field pressure taps protrude. Attach the AMP Series to the duct with sheet metal screws and replace the rubber caps on the field pressure taps. AMPLIFLOW VELOCITY PRESSURE 1000 900 800 700 600 500 FLOW Air Velocity (fpm) • • • • • • • • 400 300 200 100 .01 .02 .03 .04 .05 .06.07.08 .1 .2 .3 .4 .5 .6 .7 .8 .9 1.0 1.5 2.0 ∆P Pressure Drop ("W.C.) Velocity (fpm) = 2213 ∆P Velocity (mps) = 11.242 ∆P ORDERING INFORMATION MODEL DESCRIPTION AMP Ampliflow air velocity sensor WIDTH XX Duct width (up to 30")* Note: The ampliflow will be constructed so that the field pressure taps in the end of the sensing tube protrude through the duct. * Lengths 30'' to 96'' available by special order. Provide field-constructed support for sensors >30''. Nailor Ind. U.S. Patent No. 4,735,100 CX, RX, XLdp Series M264 Series T-110 March 2014 RELATED PRODUCTS Ashcroft differential pressure transmitters Setra differential pressure transmitter 3/8" OD black poly tubing, 1 coil, 250 ft (76 m) WE MAKE IT EASY. PAGE 1014 901 kele.com 888-397-5353 USA 279 FLOW NEW! DIFFERENTIAL PRESSURE FLOW SENSOR DPFS SERIES The Kele DPFS Series differential pressure flow sensor is the most economical way to sense airflow velocity in VAV ducts, and other small size branch ducts in HVAC systems. The DPFS Series is available in 4 different lengths for flow sensing in duct sizes from 4" to 18" (10 to 46 cm) and can reliably sense velocities above 1000 FPM (feet/minute) or 305 MPM (meters/minute). FLOW 6 INSTALLATION Select the appropriate DPFS model to fit the duct size; the flow sensor length needs to be at least half the duct width in order to get a good reading of the velocity pressure. The DPFS-1 is for 4" to 6" ducts; the DPFS-2 is for 6" to 8" ducts; the DPFS-3 is for 8" to 10" ducts and the DPFS-4 is for 10" to 18" ducts. Mounting the DPFS Series sensor requires a 7/8" (2.2 cm) hole in the duct, through which the probe insert. The DPFS requires 10 straight duct diameters upstream and 10 downstream for accurate readings. The sensor must be mounted with the flow direction arrow accurately pointing in the direction of the airflow. To ensure reliable performance, the sensor pickup openings must be kept free of dirt and dust accumulation. Using 1/4" OD poly tubing, connect the DPFS "H" port to a differential pressure gauge or transmitter "High" input port, and the "L" port to the gauge or transmitter's "Low" input port FLOW PERFORMANCE 0.900 0.800 Differential Pressure ("WC) DESCRIPTION 0.700 0.600 DPFS-1 0.500 DPFS-2 DPFS-3 0.400 DPFS-4 0.300 0.200 0.100 0.000 500 1000 1500 2000 2500 3000 Velocity (FPM) DPFS-1 DPFS-2 DPFS-3 DPFS-4 Velocity = 3285(√∆P) Velocity = 3365(√∆P) Velocity = 3490(√∆P) Velocity = 3425(√∆P) Notes: 1. Test data based on round duct sizes 6" (DPFS-1), 8" (DPFS-2), 10" (DPFS-3) and 12" (DPFS-4 ) 2. Flow coefficients were derived by averaging data for each sensor size. SPECIFICATIONS Connections 3/16" (0.48 cm) OD connections for 1/4" (0.64 cm) OD poly tubing Operating Temperature40° to 120°F (4° to 49°C) Mounting Flange 4" x 2" flange with integral foam gasket and two 3/16" holes spaced 3.3" (8.4 cm) center-to-center Materials Of Construction ABS Dimensions DPFS-1 4.0"W x 2.1"H x 3.6"L (10.2 x 5.3 x 9.1 cm) DPFS-2 4.0"W x 2.1"H x 6.0"L (10.2 x 5.3 x 15.2 cm) DPFS-3 DPFS-4 Approvals Weight DPFS-1 DPFS-2 DPFS-3 DPFS-4 Warranty 4.0"W x 2.1"H x 8.3"L (10.2 x 5.3 x 21.1 cm) 4.0"W x 2.1"H x 10.6"L (10.2 x 5.3 x 26.9 cm) RoHS 0.04 lb (0.02 kg) 0.06 lb (0.03 kg) 0.07 lb (0.032 kg) 0.08 lb (0.036 kg) 2 years ORDERING INFORMATION MODEL DPFS-1 DPFS-2 DPFS-3 DPFS-4 DESCRIPTION Differential pressure flow sensor, 3.0" insertion, for 4" to 6" ducts Differential pressure flow sensor, 5.2" insertion, for 6" to 8" ducts Differential pressure flow sensor, 7.5" insertion, for 8" to 10" ducts Differential pressure flow sensor, 9.7" insertion, for 10" to 18" ducts CX, RX, XLdp Series M264 Series T-101 RELATED PRODUCTS Ashcroft differential pressure transmitters Setra differential pressure transmitter 1/4" OD black poly tubing, 1 coil, 250 ft (76 m) Cost-saving 10-packs are available; order model with "...-10PAK" suffix. 280 888-397-5353 USA kele.com WHEN YOU NEED IT RIGHT, RIGHT NOW, CALL KELE. PAGE 1014 901 March 2014 NEW! FLOW DIFFERENTIAL PRESSURE FLOW SENSORS SSS-1000 SERIES DESCRIPTION The SSS-1000 Series airflow sensors sense differential (velocity) pressure of VAV units and other locations in main or branch ducts. Four different lengths allow selection of the sensor to yield accurate readings on terminal box inlet diameters from 4" to 16" (10.2 to 40.6 cm). SPECIFICATIONS Operating Temperature Mounting Length SSS-1002 SSS-1003 SSS-1004 SSS-1005 Storage Temperature Approvals Weight SSS-1002 SSS-1003 SSS-1004 SSS-1005 Warranty 1/4" (6.4 mm) OD connections, fit 3/8" (9.5 mm) OD polyethylene tubing 40°F to 120°F (4°C to 49°C) Integral flange with foam gasket 3.16" (8.0 cm) insertion (one sensing point) 5.41" (13.7 cm) insertion (two sensing points) 7.66" (19.4 cm) insertion (three sensing points) 9.91" (25.2 cm) insertion (four sensing points) -40° to 140°F (-40° to 60°C) RoHS SSS-1000 Series PERFORMANCE 0.04 lb (0.02 kg) 0.05 lb (0.02 kg) 0.06 lb (0.03 kg) 0.07 lb (0.03 kg) 2 years DIMENSIONS H FLOW 3.5 (8.89) in (cm) 6 ∆P Inches "W.C. Connections L 1.25 (3.18) Flow 0.1875 (0.477) diameter mounting holes (2) 1000 2000 Velocity (fpm) 2.75 (6.99) SSS-1002 SSS-1003 SSS-1004 SSS-1005 Note: See specifications for insertion dimensions Velocity = 3450 Velocity = 3300 Velocity = 3200 Velocity = 3200 ∆P ∆P ∆P ∆P INSTALLATION The SSS-1000 Series sensor requires a 7/8" (2.22 cm) diameter cutout for the insertion portion and two pilot holes for sheet metal screws or rivets to hold the flange against the ductwork. Sensors should be installed as level as possible to ensure accurate velocity pressure readings. ORDERING INFORMATION Model SSS-1002 SSS-1003 SSS-1004 SSS-1005 March 2014 Description Differential pressure flow sensor, 3.16" insertion Differential pressure flow sensor, 5.41" insertion Differential pressure flow sensor, 7.66" insertion Differential pressure flow sensor, 9.91" insertion B-265 ACCESSORIESPAGE Barb coupling, 3/8" OD tubing to 1/4" OD tubing 903 CX, RX, XLdp Series M264 Series T-110 RELATED PRODUCTS Ashcroft differential pressure transmitters Setra differential pressure transmitter 3/8" OD black poly tubing, 1 coil, 250 ft (76 m) WE MAKE IT EASY. PAGE 1014 901 kele.com 888-397-5353 USA 281 FLOW AIR VELOCITY TRANSMITTERS EE65 AND EE66 SERIES DESCRIPTION The E+E EE65 and EE66 Series airflow velocity transmitters are ideal for accurate ventilation control applications. They incorporate innovative hot film anemometer technology which guarantees good accuracy at low airflow velocity and is superior to conventional anemometers with commercial temperature sensors or NTC bead thermistors. The hot film sensor is also less sensitive to dust and dirt, for high reliability and low maintenance costs. The EE65 and EE66 series are available with current or voltage output with the measuring range and the response time jumper selectable in the field. The EE66 is specifically designed for very low airflow velocities and is accurate down to approximately 30 fpm (0.15 m/s). NEW! FEATURES 6 • Adjustable insertion length for precise measurement • Jumper selectable ranges and outputs for application flexibility • Jumper selectable time constant for signal stability • Dust and splash-proof NEMA 4 (IP65) enclosure allows installation in potentially wet areas • Very low flow velocity EE66 model for clean rooms and other low velocity applications WIRING DIMENSIONS 0.47 (12.0) 1.46 (37.2) 0.71 (18.0) A Power supply 24 VAC/VDC ± 20% 3.15 (80.0) + ~ V+ ~ FLOW EE65-01-VB5 V+ = supply voltage GND = ground AV = airflow output GND AV 1 2 3 A = 3.9" (100) or 7.9" (200) V/mA 3.15 (80.0) SPECIFICATIONS Supply Voltage Supply Current Output Signal Loads 24 VAC ±20%, 50/60 Hz, 24 VDC ±20% 150 mA @ 24 VAC, 90 mA @ 24 VDC 0-10 VDC or 4-20 mA; jumper selectable 0-10 VDC output, 10kΩ minimum resistance; 4-20 mA output, 450Ω maximum resistance Terminal strip with 1/2" NPT conduit connector or M16x1.5 cable gland for 0.18" to 0.39" (0.45 to 10.0 cm) cable diameter Wiring Accuracy EE65 EE66 Response Time ±40 fpm (0.2 m/s), plus 3% of measured value, at 68°F (20°C) and 45% RH ±7.9 fpm (0.04 m/s), plus 2% of measured value, at 68°F (20°C) and 45% RH 0.7 or 4 seconds, jumper selectable Operating Temperature Probe= Electronics= Velocity Range EE65 EE66 Enclosure Rating Dimensions -VB3 -VB5 Weight -VB3 -VB5 Approvals Warranty -13°F to 122°F (-25°C to 50°C) 14°F to 122°F (-10°C to 50°C) 0-2000 fpm (0-10 m/s), 0-3000 fpm (0-15 m/s) or 0-4000 fpm (0-20 m/s) 0-200 fpm (0-1.0 m/s), 0-300 fpm (0-1.5 m/s) or 0-400 fpm (0-2.0 m/s) NEMA 4 (IP 65) 3.2"H x 3.2"W x 5.4"D (8.0 x 8.0 x 13.7 cm) 3.2"H x 3.2"W x 9.3"D (8.0 x 8.0 x 23.7 cm) 0.25 lb (0.11 kg) 0.30 lb (0.14 kg) CE, RoHS 1 year ORDERING INFORMATION 282 MODEL EE65-01-VB3 EE65-01-VB5 EE66-01-VB3 EE66-01-VB5 DESCRIPTION Air velocity transmitter, probe length 3.9" (100 mm) Air velocity transmitter, probe length 7.9" (200 mm) Low flow transmitter, probe length 3.9" (100 mm) Low flow transmitter, probe length 7.9" (200 mm) 691-K0A DCP-1.5-W RELATED PRODUCTS Control transformer, 120:24 VAC, 40 VA, Class 2 Power supply, 24 VAC IN to 24 VDC OUT 888-397-5353 USA kele.com WHEN YOU NEED IT RIGHT, RIGHT NOW, CALL KELE. PAGE 979 995 March 2014 NEW! FLOW AIR VELOCITY TRANSMITTER AVS-200 DESCRIPTION The Kele AVS-200 is an electronic air velocity transmitter for use in HVAC systems, laboratories, and industrial applications. It features three DIP switch-selectable velocity ranges and two analog outputs (one voltage, one current). The AVS-200 also has a selectable time constant (the time it takes to register 63.2% of a velocity change) of 3 or 10 seconds. The sensing probe has an adjustable insertion length of up to 8" (20.3 cm) and a 4.5' (1.4 m) cable. AVS-200 FEATURES • • • • Three DIP switch-selectable velocity ranges Two analog outputs Selectable time constant Dust- and splash-proof (IP44) enclosure 6 SPECIFICATIONS Supply Voltage Supply VA Output Signal Loads Wiring Accuracy Repeatability Temperature Effect WIRING INSTALLATION AVS-200 1 - Internal Connection 2 + 24 VAC 3 4 5 0-20 mA or 4-20 mA 0-10 VDC Common Note: Any device sharing a transformer with the AVS-200 must have a common power negative "-" and signal negative "-" terminal, and polarity must be observed. Otherwise, a separate transformer must be used. March 2014 Time Constant 63.2% for 3 or 10 seconds Operating Temperature Electronics 32° to 122°F (0° to 50°C) Sensing Tip -4° to 140°F (-20° to 60°C) Velocity Range 0-1000 fpm (0.5.1 m/s), 0-2000 fpm (10.2 m/s), or 0-3000 fpm (0-15.3 m/s); DIP switch selectable Probe Length Range Adjustable 1" to 8" (2.5 to 20.3 cm) Enclosure Rating IP44 Approvals CE, RoHS Weight 1.8 lb (0.8 kg) Warranty 1 year FLOW 24 VAC ±10%, 50/60 Hz 5 VA 0-10 VDC, 0/4-20 mA 0-10 VDC output: 1kΩ minimum resistance; 4-20 mA output: 600Ω maximum resistance 4.5' (1.4 m) cable from transmitter to probe; screw terminals inside transmitter housing ±5% of measured value plus 0.5% of measuring range 0.5% of measuring range Maximum 0.1%/°C (0.2%/°F) The sensing probe must be installed through a 5/8"(16mm) hole in the duct with the arrow on the mounting flange pointing in the direction of the airflow. The tab on the mounting flange should be aligned with the line on the probe to ensure proper airflow measurement. The insertion length is adjustable. Loosen the set screw, and move the probe to the selected position. The scale on the probe shows the insertion length. Always install the sensing probe downstream of filters and coils. Avoid placement directly in the outside air stream. For best accuracy, locate the sensing probe a minimum of 10 duct diameters (or widths) upstream of any obstruction and a minimum of 10 duct diameters downstream. ORDERING INFORMATION MODEL AVS-200 DESCRIPTION Air velocity transmitter 691-K0A RELATED PRODUCTS Control transformer, 120:24 VAC, 40 VA, Class 2 WE MAKE IT EASY. PAGE 979 kele.com 888-397-5353 USA 283 FLOW AIR FLOW A2G-20 SERIES DESCRIPTION The Wika A2G-20 Series air velocity transmitter is jumper selectable and features a separate signal out for temperature, three velocity ranges, and one temperature range. Applications include supply and exhaust fan tracking; clean room air; lab air handling and paint booth supply air. For both the air velocity (FPM) and for the temperature signals, the user can select either of two outputs (0-10V or 4-20 mA). Additional options include a digital display and a SPDT relay. The digital display shows both the measured value and the relay settings. 6 FEATURES • Three ranges; jumper selectable: 0 to 390 FPM, 0 to 1970 FPM, 0 to 3940 FPM • One temperature range 32° to 122°F (0° to 50°C) • User selectable output signals: 0-10V or 4-20 mA • Duct installation FLOW NEW! A2G-20 Series SPECIFICATIONS Supply Voltage Output Signal (Air Velocity) Output Signal (Temperature) Wiring Accuracy (Air) 0 to 390 FPM 0 to 1,970 FPM 0 to 3940 FPM AC/DC 24V ± 10% 0-10 V (linear to FPM), load min or 4-20 mA (linear to FPM), load max 0-10 V (linear to °F), load min 1kΩ or 4-20 mA (linear to °F), load max 400Ω PG-gland M16 <19.6 FPM (±5%) <98.1 FPM (±5%) <196.2 FPM (±5%) Accuracy (Temperature) >1.2°F (<0.5°C) Velocity Range (Air) 0 to 390 FPM 2 m/s range selectable by jumper 0 to 1,970 FPM 10 m/s range selectable by jumper 0 to 3940 FPM 20 m/s range selectable by jumper Temperature Range 32° to 122°F (0° to 50°C) Operating Temperature32° to 122°F (0° to 50°C), max. 85% rH Enclosure Rating Plastic (ABS) Nema 3 Approvals RoHS, WEEE Warranty 1 year WIRING 284 888-397-5353 USA kele.com WHEN YOU NEED IT RIGHT, RIGHT NOW, CALL KELE. March 2014 NEW! FLOW AIR FLOW A2G-20 SERIES DIMENSIONS 6 FLOW ORDERING INFORMATION March 2014 MODEL A2G20-V00-3X-1AAF-M-Z A2G20-V00-3X-1AAF-M-A A2G20-V00-3X-1AAF-M-B DESCRIPTION Air velocity transmitter, no digital display and no relay Air velocity transmitter with digital display, no relay Air velocity transmitter with digital display and SPDT relay DCPA-1.2 691-K0A DCP-1.5-W RELATED PRODUCTSPAGE Power supply, 120 VAC IN to 24 VAC/24 VDC OUT 994 Control transformer, 120:24 VAC, 40 VA, Class 2 979 Power supply, 24 VAC IN to 24 VDC OUT 995 WE MAKE IT EASY. kele.com 888-397-5353 USA 285 FLOW THERMAL MASS FLOW METER FT2A SERIES DESCRIPTION The Fox FT2A Series thermal mass flow meters are perfect for measuring flow of natural gas, compressed air, propane, oxygen, and most common gases. The flow meters measure both flow rate and temperature with isolated 4-20 mA outputs for both variables. In addition, a separate pulse output can be used for logging total gas flow. The FT2A mass flow meters measure gas flow velocity as low as 50 sfpm (standard feet/ minute) and as high as 50,000 sfpm, without the need for temperature or pressure compensation. 6 Each flow meter is calibrated at the factory using the same gas as the application. As a result, the FT2A more than meets EPA accuracy requirements for monitoring both boiler intake gas and combustion emissions. FLOW Standard models include a 2 line x 16 character bright white backlit display for viewing flow rate, flow total, elapsed time, process gas temperature and alarms. The FT2A has an integral keypad for setting parameters such as signal spans, pulse frequency scaling, pipe area, zero cutoff, filtering, diagnostics and alarms. The FT2A Series is available in two styles, inline or insertion. The inline models (male NPT) include built-in flow conditioners which reduce the need for long straight runs of upstream and downstream pipe. The most common inline sizes are 1/2" to 2" and other inline sizes are available. The insertion models install in a 3/4" coupling (field provided) and are available in insertion lengths to fit pipes from 1-1/2" to 72". Both inline and insertion styles come standard with stainless steel wetted parts, an integral NEMA 4X enclosure rated for Class I, Div. 2, Groups B,C,D hazardous areas, and a NIST calibration certificate. NEW! C FM US APPROVED APPLICATION Natural gas, air, ammonia, biogas, butane, compressed air, carbon monoxide, carbon dioxide, ethane, ethylene, helium, hydrogen, methane, nitrogen, oxygen, propane, and more FEATURES • Measures gas flow rate in SCFM, SCFH, NM3M, NM3H, KG/M, KG/H, and more, for complete choice in units • Two 4-20 mA analog outputs, flow rate and temperature • RS485-Modbus, Isolated BACnet MS/TP, Profibus-DP, DeviceNet and Ethernet Modbus TCP models available for network communication • Insertion or inline mounting styles for installation choices • All welded 316SS sensor construction and no moving parts for durability and long life • Field programmable for flexibility in configuration • Standard NEMA 4X enclosure designed for Class I, Division 2, Groups B, C, and D • NIST traceable calibration standard to assure accuracy • Free FT2A View™ Software available SPECIFICATIONS Supply Voltage Supply Watts Output Signal Wiring Wiring Terminations Communication Interface Accuracy Temperature Repeatability Mounting 286 24 VDC ±10%, 85-264 VAC 50/60 Hz 20 Watts DC, 12 Watts AC 2 isolated 4-20 mA outputs (one for flow and one for temperature); 1 isolated pulse output 0-100Hz, 10V p/p for flow (can be used for alarming) Two 3/4" NPT conduit connections on sides of housing Screw terminals USB Port-optional: for connection to computer, models available with RS485-Modbus BACnet MS/TP, Profibus-DP, DeviceNet and Ethernet Modbus TCP Flow: ±1% of reading, ±0.2% of full scale ±1.8°F (±1.0°C) over -40° to 250°F (-40° to 121°C) ±0.2% of full scale 1/2" MNPT pipe section to 2" MNPT pipe section (standard inline), 3/4" 888-397-5353 USA kele.com MNPT coupling, 6" length probe for 1-1/2" to 6" pipes (standard insertion, other lengths available) Operating Temperature32° to 140°F (0° to 60°C) Media Compatibility Standard configuration for natural gas; other gases such as air, biogas, butane, carbon monoxide, carbon dioxide, nitrogen, methane, oxygen, propane, etc. optional. Media Temperature Range -40° to 250°F (-40° to 121°C) Maximum Pressure Rating 300 psig (21 bar) Materials Of Construction 316 stainless steel sensor and flow body Enclosure Rating NEMA 4X, designed for Class I, Division 2, Groups B, C & D hazardous areas Approvals CE, FM/FMc Weight 8.0 lb (3.6 kg) to 10.0 lb (4.5 kg) inline models, 6.0 lb (2.7 kg) 6" insertion model Warranty 1 year WHEN YOU NEED IT RIGHT, RIGHT NOW, CALL KELE. March 2014 NEW! FLOW THERMAL MASS FLOW METER FT2A SERIES WIRING Figure 1: Connections for 24VDC Supply Figure 2: Connections for Optional AC Power +24VDC 24V Return Earth Ground AC AC 76 76 ) FT2A 76 76 $& $& 76 4 to 20mA FLOW RATE 24VDC Return +24VDC 4 to 20mA TEMPERATURE OR FLOW RATE Customer PLC or DCS +24VDC 76 (+) (-)( Figure 3: 4 to 20mA Output Wiring for Customer-Supplied Power Source Earth Ground 24VDC Return 76 76 6 Figure 4: 4 to 20mA Output Wiring for Loop Power Provided by FT2A Figure 5: Frequency/Alarm Output Isolated (Recommended) 24V 76 + Customer PLC or DCS FT2A 76 - 76 76 4 to 20mA FLOW RATE - + 2.4K to 10K OHM 4 to 20mA TEMPERATURE OR FLOW RATE +24VDC Frequency or Alarm Output - 24VDC Return FLOW Customer PLC or DCS 76 + FT2A 76 76 76 DIMENSIONS 3.3 (8.4) Signal Wiring Input Power 1.4 (3.5) Signal Wiring Input Power 3.2 (8.1) 3.9 (10.0) 1.50 (3.8) 5.35 (13.6) 2x 3/4 inch NPT Female 7.12 (18.1) 7.12 (18.1) MODEL TFH1000 Gas Mass Flowmeter & Temperature Transmitter Female “HH” MODEL TFH1000 Gas Mass Flowmeter & Temperature Transmitter “H” “LL” 2x NPT Male Thread FLOW CL CL “L” March 2014 WE MAKE IT EASY. kele.com 888-397-5353 USA 287 FLOW THERMAL MASS FLOW METER FT2A SERIES MODEL FT2A 6 NEW! ORDERING INFORMATION DESCRIPTION Gas Mass Flowmeter PROBE/BODY 05P 1/2" MNPT Inline, flow range 0-48 scfm 075P 3/4" MNPT Inline, flow range 0-120 scfm 10P 1" MNPT Inline, flow range 0-192 scfm 125P 1 1/4" MNPT Inline, flow range 0-320 scfm 15P 1 1/2" MNPT Inline, flow range 0-450 scfm 20P 2" MNPT Inline, flow range 0-750 scfm 06IE Insertion, 6" probe, flow range (see table) SENSOR MATERIAL SS 316 Stainless steel sensor and flowbody SENSOR TYPE ST Standard, -40-250°F (-40-121°C) ENCLOSURE/POWER E1 Local NEMA 4X, 24 VDC Power E2 Local NEMA 4X, 85-264 VAC Power BUS OPTIONS B0 No communication bus FLOW MB Modbus, BN, BACnet, MS/TP BN BACnet, MS/TP BD DeviceNet BP ProfiBus-DP BE Ethernet Modbus TCP CALIBRATION G1 Air, N2; max flow less than 1200 SCFM (2040 NM3H) G2 Air, N2; max flow greater than 1200 SCFM (2040 NM3H) Ar, CO2, H2, CH4, Natural Gas, O2; max flow less than 1000 SCFM G3 (1700 NM3H) Ar, CO2, H2, CH4, Natural Gas, O2; max flow greater than 1000 G4 SCFM (1700 NM3H) CO, He, Ammonia, Propane, Digester gas; max flow less than 700 G5 SCFM (1190 NM3H) CO, He, Ammonia, Propane, Digester gas; max flow greater than 700 G6 SCFM (1190 NM3H) Example: FT2A-05P-SS-ST-E1-B0-G3; 1/2" NPT inline, 316SS, standard temp., 24 VDC power, display/keypad, no communication, for natural gas <1000 SCFM. NOTE: An FT2A Series Application Data form must be filled out and sent in with the purchase order. Details regarding application and media parameters are required for factory calibration. The form is located at www.kele. com under Flow/FT2 Series/Related Products. 102299 102878 104870 DCP-1.5-W DCPA-1.2 288 888-397-5353 USA ACCESSORIESPAGE 90° elbow mounting kit, makes housing upright in vertical pipe installations Teflon ferrule kit, for ease in removal of the insertion models USB Cable Power supply, 24 VAC IN to 24 VDC Out 995 Power supply, 120 VAC In to 24 VAC/24 VDC Out 994 kele.com WHEN YOU NEED IT RIGHT, RIGHT NOW, CALL KELE. March 2014 NEW! FLOW FLOW SENSOR WITH INTEGRAL FLOW TRANSMITTER SDI SERIES DESCRIPTION The Badger Meter SDI Series flow sensor has an integral transmitter and is available in either brass or stainless steel. Hot tap stainless steel models include isolation valve and mounting hardware which enables flowmeter installation and removal while the piping system is pressurized; system shutdown is unnecessary. Hot tap stainless steel models are also available for bidirectional flow measurement. The impeller is rugged and non-fouling and requires no custom calibration. The SDI Series is available with a frequency output, analog output, or a scaled-pulse output and the display is optional; programming is done using the A301-20 Programming Kit. Stainless steel models are available with a PEEK (polyetheretherketone) tip for high fluid temperatures (up to 300 °F). SDI Series 6 FEATURES • • • • • • • • Direct insertion or hot tap installation Fits pipe sizes 1.5" to 36"+ (3.8 to 91+ cm) Mounts in 1" NPT tap, weld-on or pipe saddle Low pressure drop Optional 8 character 3/8" (0.95 cm) LCD NEMA 4X enclosure standard Bidirectional models available Field programmable with optional software Supply Voltage 8-35 VDC Supply Current 25 mA Maximum Output Impedance 750Ω @ 24 VDC Output Signal Models with standard frequency pulse, two-wire 4-20 mA, scaled pulse, or bi-directional (hot-tap models only) Wiring Terminations Screw terminals Conduit Connection 1/2" FNPT Configuration A-SDI Programming software kit, includes 20' cable Accuracy ± 1% of flow rate Repeatability ± 0.5% Display One line, eight character 3/8" (.95 cm) LCD, annunciators for rate, total, input, output Operating Temperature 14° to 150°F (20° to 65°C) Velocity Range 0.3 to 20 fps (.09 to 6.1 mps) Installation Install in straight pipe section with a minimum distance of 10 pipe diameters upstream and 5 pipe diameters downstream to any bend, obstruction or transition Mounting 1" MNPT, mount in Thredolet® or pipe saddle Media Temperature RangeMaximum 300°F (149°C) for PEEK tip; 180°F (82°C) for PPS tip Maximum Pressure 1000 psig (6895 kPa) for stainless steel, 600 psig (4137 kPa) for brass Pressure Drop 0.5 psid (3.5 kPa), or less, at 10 fps velocity Materials Of Construction Polypropylene enclosure with Viton® sealed dacrylic cover, probe and sensor materials vary by model number (see ORDERING INFORMATION) Enclosure Rating NEMA 4X Warranty 1 year March 2014 MODEL DESCRIPTION SDI Flow sensor with integral transmitter MATERIAL 0D1N Stainless steel insertion with PPS tip for 1.5" to 10" pipes 0D2N Stainless steel insertion with PPS tip for 12"" to 36" pipes 0D3N Stainless steel insertion with PPS tip for 36"+ pipes 1D1N Brass insertion with PPS tip for 1.5" to 10" pipes 1D2N Brass insertion with PPS tip for 12" to 36" pipes 1D3N Brass insertion with PPS tip for 36"+ pipes 2D1N Stainless steel insertion with PEEK tip for 1.5" to 10" pipes 2D2N Stainless steel insertion with PEEK tip for 12" to 36" pipes 2D3N Stainless steel insertion with PEEK tip for 36"+ pipes 0H1N Stainless steel hot tap with PPS tip for 1.5" to 10" pipes 0H2N Stainless steel hot tap with PPS tip for 12" to 36" pipes 0H3N Stainless steel hot tap with PPS tip for 36"+ pipes 2H1N Stainless steel hot tap with PEEK tip for 1.5" to 10" pipes 2H2N Stainless steel hot tap with PEEK tip for 12" to 36" pipes 2H3N Stainless steel hot tap with PEEK tip for 36"+ pipes OUTPUT 0 Standard frequency pulse 1 4-20 mA 2 Scaled pulse 5 Bidirectional, 4-20 mA + direction (hot tap, PPS tip only) 6 Bidirectional, scaled pulse (hot tap, PPS tip only) DISPLAY 0 No display 1 LCD option (not available with output option 0) CONSTRUCTION 0200 Viton O-ring, Carbide shaft, stainless steel impeller, Torlon bearing (std) 1200 EPDM O-ring, Carbide shaft, stainless steel impeller, Torlon bearing SDI 2D1N 1 8132030 A-1027 A301-20 WE MAKE IT EASY. 1 FLOW SPECIFICATIONS ORDERING INFORMATION 0200 Example: SDI2D1N11200 Flow sensor with integral transmitter, stainless steel insertion with PEEK tip, 4-20 mA output, display, standard construction. ACCESSORIES Replacement ball valve for hot tap install Hot tap adapter nipple, required for hot tap Flow/BTU transmitter programming kit, Includes cable kele.com 888-397-5353 USA 289 FLOW FLOW SENSORS 200 SERIES OVERVIEW DESCRIPTION 6 The Badger Meter 200 Series flow sensors feature a sixbladed impeller with a proprietary nonmagnetic sensing mechanism. The design provides higher and more constant torque than four-bladed impeller designs and is less prone to be fouled by waterborne debris. The forward curveshape, coupled with the absence of magnetic drag, provides improved operation and repeatability at lower flow rates. This is especially true where the impeller is exposed to metallic or rust particles found in steel or iron pipes. As the liquid flow turns the impeller, a low impedance signal is transmitted with a frequency proportional to the flow rate. This signal can travel up to 2,000' (610m) between the sensor and the transmitter without the need for amplification. All sensors are supplied with 20' (6.10m) of Belden type 9320 (two-conductor shielded) cable. Standard construction of the 200 Series sensors consists of EPDM O-rings, tungsten carbide shaft, nylon impeller, and UHMWPE bearings. 228 SS-2 226B 250B 220B FLOW A complete line of flow transmitters is available for use with these flow sensors. The 200 Series can be used for potable water and the following pages contain details on each model. NEW! 225B SELECTION CHART MODEL DESCRIPTION PIPE SIZE in (cm) 220B 220SS 225B 226B 226SS 228C-2 228B-2 228SS-2 2-1/2 (6.35) and up 2-1/2 (6.35) and up 2-1/2 (6.35) and up 2-1/2 (6.35) and up 2-1/2 (6.35) and up 2 (5.08) 2 (5.08) 2 (5.08) 250B Brass, insertion type Stainless steel, insertion type Brass, retractable with gate valve Brass, retractable with ball valve Stainless steel, retractable with ball valve Brass sensor in a 2" (5.08 cm) cast iron tee Brass sensor in a 2" (5.08 cm) brass tee Stainless steel sensor in a 2" (5.08 cm) stainless steel tee Removable sensor in a cast bronze tee 228PV 4000 Series Removable sensor in a PVC tee PVC 290 888-397-5353 USA kele.com 1/2 (1.27) , 3/4 (1.91), 1 (2.54), 1-1/4 (3.18), 1-1/2 (3.81) 1-1/2 to 4 (3.81 to 10.16) PVC 1/2 (1.27), 3/4 (1.91), 1 (2.54) PVC WHEN YOU NEED IT RIGHT, RIGHT NOW, CALL KELE. March 2014 NEW! FLOW BRASS & STAINLESS STEEL FLOW SENSORS 220B, 220SS DESCRIPTION The 220B (brass) and 220SS (stainless steel) flow sensors mount in a 2" NPT pipe saddle or Thredolet® and are used in general flow measuring applications in metallic or PVC pipes from 2-1/2" to 40" (6.4 to 101 cm) size. Positioning nuts on the three threaded retaining rods allow the sensor to be accurately positioned to a standard insertion depth of 1-1/2" into the pipe. When this insertion depth is maintained, and there are at least 10 upstream and 5 downstream diameters of straight uninterrupted flow, an accuracy of ±1% of actual flow rate can be obtained between flow velocities of 0.5 to 30 ft/sec. The standard 200 Series flow sensor are rated for water temperatures to 221 °F. For higher temperature requirements, see the SDI Series. 220B 6 SPECIFICATIONS Connections Materials Of Construction 220B Standard construction is Admiralty brass UNS C44300 sleeve, glassreinforced nylon impeller, Pennlon® UHMWPE bearings, tungsten carbide shaft, glass reinforced PPS housing, and ethylene propylene EPDM o-rings (other materials available special order). 220SS Standard construction is 300 series stainless steel sleeve, glassreinforced nylon impeller, Pennlon® UHMWPE bearings, tungsten carbide shaft, glass reinforced PPS housing, and ethylene propylene EPDM o-rings (other materials available special order). Dimensions 7.1"H x 3" diameter (18.1 x 7.6 cm) Approvals CE Weight 4.1 lb (1.9 kg) Warranty 1 year FLOW 2" MNPT (mount in Thredolet® or tee) Wiring 20' (6.1 m) Belden 9320 twoconductor shielded cable Accuracy ±1% of full scale Repeatability ±0.3% of full scale Linearity ±0.2% of full scale Rangeability 60:1 Velocity Range 0.5 to 30 fps (.15 to 9.0 mps) Media Compatibility Hot water, chilled water, water/glycol, potable water (verify application is compatible with flow sensor materials of construction, check material compatibility resources prior to ordering) Media Temperature Range Maximum 221°F (105°C) Maximum Pressure 400 psig (2758 kPa) @ 100°F (37.8°C) media temperature ORDERING INFORMATION March 2014 MODEL 220B 220SS DESCRIPTION Brass flow sensor Stainless steel flow sensor 310-00 UFT-1A RELATED PRODUCTS Programmable analog flow transmitter Universal flow transmitter, pulse and calibrated 4-20 mA output 230-FRK 2X2.5-3THD 2X4-6THD 2X8-36THD ACCESSORIES Repair kit for 200 Series flow sensors (includes impeller, shaft, bearing, and O-ring) 2" Thredolet ® for 2-1/2" and 3" pipes 2" Thredolet ® for 4", 5" and 6" pipes 2" Thredolet ® for 8" to 36" pipes WE MAKE IT EASY. kele.com PAGE 296 297 888-397-5353 USA 291 FLOW HOT TAP FLOW SENSORS 225B, 226B, 226SS SERIES DESCRIPTION 6 The Badger Meter 225B, 226B, 226SS Series hot tap flow sensors feature an elongated sensor, special mounting adapter, pipe nipple, and isolation valve to allow the nonmagnetic impeller sensor to be installed into a pressurized pipe while the pipe is in service. This is accomplished by first attaching a 2'' saddle or Thredolet® onto the pipe and screwing the nipple and isolation valve into the saddle or fitting. A hole is then drilled through the pipe using a commercial tapping machine. When complete, the tapping apparatus is removed, the isolation valve is closed, and the sensor is installed. The 225B, 226B, 226SS Series can be used for pipe sizes 2-1/2" to 40" (6.4 to 101 cm). The hot tap flow sensor is also recommended for any application where it would be difficult to shut down or drain the pipeline to remove the sensor for service. The overall length of the sensor tube is 18" (46 cm); however, a clearance height of 36" (91 cm) should be allowed for the fully extended length of the insertion tool. NEW! Model HTT Model 225B Model 226B SPECIFICATIONS FLOW Connections Wiring 2" MNPT 20' (6.1 m) two-conductor 20 AWG U.L. Type PTLC shielded cable Accuracy ±1% of full scale Repeatability ±0.3% of full scale Linearity ±0.2% of full scale Rangeability 60:1 Velocity Range 0.5 to 30 fps (.15 to 9.0 mps) Media Compatibility Hot water, chilled water, water/glycol, potable water (verify application is compatible with flow sensor materials of construction, check material compatibility resources prior to ordering) Media Temperature RangeMaximum 221°F (105°C) Maximum Pressure 225B 300 psig (2069 kPa) @ 100°F (37.8°C) media temperature 226B, 226SS 400 psig (2758 kPa) @ 100°F (37.8°C) media temperature Materials Of Construction 225B, 226B Standard construction is Admiralty brass 226SS Dimensions Approvals Weight 225B 226B, 226SS HTT Warranty UNS C44300 sleeve, glass-reinforced nylon impeller, Pennlon® UHMWPE bearings, tungsten carbide shaft, glass reinforced PPS housing, and ethylene propylene EPDM o-rings (other materials available special order). Standard construction is 300 series stainless steel sleeve, glass-reinforced nylon impeller, Pennlon® UHMWPE bearings, tungsten carbide shaft, glass reinforced PPS housing, and ethylene propylene EPDM o-rings (other materials available special order). 18"H x 3" diameter (46 x 7.6 cm) plus valve handle CE 17.5 lb (7.9 kg) 13.0 lb (5.9 kg) 12.0 lb (5.4 kg) 1 year ORDERING INFORMATION 292 MODEL 225B 226B 226SS DESCRIPTION Brass hot tap flow sensor with gate-type isolation valve Brass hot tap flow sensor with ball-type isolation valve Stainless steel hot tap flow sensor with ball-type isolation valve 230-FRK 2X2.5-3THD 2X4-6THD 2X8-36THD 813144-1211 HTT 81873 ACCESSORIES Repair kit for 200 Series flow sensors (includes impeller, shaft, bearing, and O-ring) 2" Thredolet® for 2-1/2" and 3" pipes 2" Thredolet® for 4", 5" and 6" pipes 2" Thredolet® for 8" to 36" pipes Replacement sleeve assembly for 225B, 226B flow sensors Hot tap tool Replacement gate valve for 225B, 2" 310-00 UFT-1A RELATED PRODUCTS Programmable analog flow transmitter Universal flow transmitter, pulse and calibrated 4-20 mA output 888-397-5353 USA kele.com WHEN YOU NEED IT RIGHT, RIGHT NOW, CALL KELE. PAGE 296 297 March 2014 NEW! FLOW TEE-MOUNTED FLOW SENSORS 228B, 228C, 228SS DESCRIPTION The Badger Meter 228B is a brass flow sensor mounted in a 2" bronze tee with 2" copper solder couplings included, the 228C is a brass flow sensor mounted in a 2" cast iron tee, and the 228SS is a stainless steel flow sensor mounted in a 2" stainless steel tee. 228 SS-2 SPECIFICATIONS Connection Type 228B 228C, 228SS Wiring 228C 228SS Dimensions Approvals Weight 228B 228C 228SS Warranty 6 FLOW 2" solder 2" FNPT 20' (6.1 m) 2-conductor 20 AWG shielded UL type PTLC wire, rated to 221°F (105°C). May be extended to 2000’ maximum with similar cable Accuracy ±1% of full scale Repeatability ±0.3% of full scale Linearity ±0.2% of full scale Velocity Range 0.5 to 30 fps (.15 to 9.0 mps) Media Compatibility Hot water, chilled water, water/glycol, potable water (verify application is compatible with flow sensor materials of construction, check material compatibility resources prior to ordering) Media Temperature RangeMaximum 221°F (105°C) Maximum Pressure 228B 200 psig (1379 kPa) @ 100°F (37.8°C) media temperature 228C 175 psig (1207 kPa) @ 100°F (37.8°C) media temperature 228SS 400 psig (2758 kPa) @ 100°F (37.8°C) media temperature Materials Of Construction 228B Standard construction is cast bronze tee (Class 125 per ASME B16.15), copper couplings, admiralty brass UNS C44300 sleeve, glass-reinforced nylon impeller, Pennlon® UHMWPE bearings, tungsten carbide shaft, glass reinforced PPS housing, and ethylene propylene EPDM o-rings (other materials available special order). Standard construction is cast iron tee (class 125 per ASME B16.4), admiralty brass UNS C44300 sleeve, glassreinforced nylon impeller, Pennlon® UHMWPE bearings, tungsten carbide shaft, glass reinforced PPS housing, and ethylene propylene EPDM o-rings (other materials available special order). Standard construction is 316 stainless steel tee, 300 series SS sleeve, glassreinforced nylon impeller, Pennlon® UHMWPE bearings, tungsten carbide shaft, glass reinforced PPS housing, and ethylene propylene EPDM o-rings (other materials available special order). 8.4"H x 7.9"W x 3.0"D (21.3 x 20.0 x 7.6 cm) CE 8.8 (4.0 kg) 7.2 lb (3.3 kg) 12.0 lb (5.4 kg) 1 year ORDERING INFORMATION March 2014 MODEL 228B-2 228C-2 228SS-2 DESCRIPTION Brass flow sensor mounted in a 2" (5.08 cm) bronze tee (copper solder couplings included) Brass flow sensor mounted in a 2" (5.08 cm) cast iron pipe tee Stainless steel flow sensor mounted in a 2" (5.08 cm) stainless steel pipe tee 230-FRK 813124-1211 ACCESSORIES Repair kit for 200 Series flow sensors (includes impeller, shaft, bearing, and O-ring) Replacement sleeve assembly for 220B, 228B, 228BC flow sensors 310-00 UFT-1A RELATED PRODUCTS Programmable analog flow transmitter Universal flow transmitter, pulse and calibrated 4-20 mA output WE MAKE IT EASY. kele.com PAGE 296 297 888-397-5353 USA 293 FLOW TEE MOUNTED FLOW SENSOR 250B DESCRIPTION The Badger Meter 250B Series flow sensors consist of a removable flow sensor mounted in a cast bronze housing. They are available for 1/2'' to 1-1/2'' (1.3 to 3.8 cm) pipe sizes. NEW! 250B-0.5 6 SPECIFICATIONS reinforced nylon impeller, Pennlon® UHMWPE bearings, tungsten carbide shaft, glass reinforced PPS housing, and ethylene propylene EPDM o-rings FLOW Connection Type Wiring 1/2" FNPT to 1-1/2" FNPT 20' (6.1 m) 2-conductor 20 AWG shielded UL type PTLC wire, rated to 221°F (105°C). May be extended to 2000' maximum with similar cable Accuracy ±1% of full scale Repeatability ±0.7% of full scale Linearity ±0.7% of full scale Rangeability 60:1 Velocity Range 0.3 to 15 fps (.09 to 4.5 mps) Media Compatibility Hot water, chilled water, water/glycol, potable water (verify application is compatible with flow sensor materials of construction, check material compatibility resources prior to ordering) Media Temperature Range Maximum 221°F (105°C) Maximum Pressure 400 psig (2758 kPa) @ 100°F (37.8°C) media temperature Materials Of Construction Cast bronze UNS C83600 tee, glass- Dimensions 250B-0.5, -0.75 250B-1 250B-1.25 250B-1.5 Approvals Weight 250B-0.5 250B-0.75 250B-1 250B-1.25 250B-1.5 Warranty 4.6"H x 4.0"W x 1.6"D (11.7 x 10.2 x 4.1 cm) 4.8"H x 5.5"W x 2.1"D (12.2 x 14.0 x 5.3 cm) 5.0"H x 6.1"W x 2.4"D (12.7 x 15.5 x 6.1 cm) 5.2"H x 6.5"W x 2.6"D (13.2 x 16.5 x 6.6 cm) CE 4.6 lb (2.1 kg) 4.8 lb (2.2 kg) 6.2 lb (2.8 kg) 6.5 lb (2.9 kg) 7.6 lb (3.4 kg) 1 year ORDERING INFORMATION 294 MODEL 250B-0.5 250B-0.75 250B-1 250B-1.25 250B-1.5 DESCRIPTION Brass flow sensor mounted in a 1/2" (1.3 cm) NPT bronze pipe tee Brass flow sensor mounted in a 3/4" (1.9 cm) NPT bronze pipe tee Brass flow sensor mounted in a 1" (2.5 cm) NPT bronze pipe tee Brass flow sensor mounted in a 1-1/4" (3.2 cm) NPT bronze pipe tee Brass flow sensor mounted in a 1-1/2" (3.8 cm) NPT bronze pipe tee 310-00 813107-1211 UFT-1A RELATED PRODUCTS Programmable analog flow transmitter Replacement sensor assembly for 250B, includes 20' cable Universal flow transmitter, pulse and calibrated 4-20 mA output 888-397-5353 USA kele.com WHEN YOU NEED IT RIGHT, RIGHT NOW, CALL KELE. PAGE 296 297 March 2014 NEW! FLOW PVC TEE FLOW SENSORS 228PV SERIES DESCRIPTION The Badger Meter 228PV flow sensors are designed to measure water flow in PVC pipes. These sensors consist of a removable, nonmagnetic sensor in a schedule 80 PVC tee with solvent-weld socket end connections. They are available in 1-1/2" to 4" (3.8 to 10.2 cm) sizes. 228PV 6 SPECIFICATIONS Connection Type Wiring Materials Of Construction PVC per ASTM D-2462 and D-2467 virgin unplasticized PVC resin, approved for potable water, PPS housing, EPDM o-ring, tungsten shaft, nylon impeller, Pennlon bearings Dimensions 228PV1505 5.2"H x 5.0"W x 2.4"D (13.1 x 12.7 x 6.0 cm) 228PV2005 5.6"H x 5.6"W x 2.9"D (14.3 x 14.3 x 7.3 cm) 228PV3005 6.8"H x 6.5"W x 4.2"D (17.3 x 16.5 x 10.7 cm) 228PV4005 6.8"H x 7.4"W x 5.4"D (17.3 x 18.7 x 13.7 cm) Approvals CE Weight 228PV1505 1.0 lb (.45 kg) 228PV2005 1.0 lb (.45 kg) 228PV3005 1.5 lb (.68 kg) 228PV4005 2.5 lb (1.1 kg) Warranty 1 year FLOW Schedule 80 PVC 20' (6.1 m), 20 AWG two-conductor shielded UL type PTLC cable, rated to 221°F (105°C), may be extended to 2000' maximum with similar cable Accuracy ±1% of full scale Repeatability ±0.3% of full scale Linearity ±0.2% of full scale Pulse Rate 3.2 to 200 Hz, 5 ms ±25% width, 9-20 VDC power @ 2 mA maximum; 5V CMOS and LSTTL compatible Velocity Range 0.5 to 30 fps (0.15 to 9 mps) Media Compatibility Hot water, chilled water (verify application is compatible with flow sensor materials of construction, check material compatibility resources prior to ordering) Media Temperature Range Maximum 140°F (60°C) Maximum Pressure 100 psig (689 kPa) @ 77°F (25°C) media temperature, decreasing to 40 psig (276 kPa) @ 140°F (60°C) ORDERING INFORMATION March 2014 MODEL 228PV1505-1211 228PV2005-1211 228PV3005-1211 228PV4005-1211 DESCRIPTION Flow sensor in 1-1/2" PVC tee, pulse output Flow sensor in 2" PVC tee, pulse output Flow sensor in 3" PVC tee, pulse output Flow sensor in 4" PVC tee, pulse output UFT-1A RELATED PRODUCTS Universal flow transmitter, pulse and calibrated 4-20 mA output WE MAKE IT EASY. kele.com PAGE 297 888-397-5353 USA 295 FLOW NEW! PROGRAMMABLE ANALOG FLOW TRANSMITTER 310 SERIES DESCRIPTION The Badger Meter 310 Series programmable analog flow transmitter is a loop-powered device that converts the signal from a 200 or 4000 Series flow sensor into a linear 4-20 mA signal. An integral, adjustable electronic filter dampens the analog output for smooth, stable operation. The microprocessor-based 310 Series can be ordered preconfigured, or it can be field-configured with a computer. An A301-20 Programming Kit will configure all 310 Series transmitters. 6 SPECIFICATIONS FEATURES • 4-20 mA loop powered • Compact size • Computer programmable • Electronic signal dampening Supply Voltage Input Signal Output Signal Maximum Output Impedance Configuration WIRING 24 VDC Power Supply + Shield (if applicable) (black) (red) FLOW _ 200 Series Flow Sensor Power (4000 only) Signal (+) Signal (-) Shield Ground 4-20 mA loop (+) _ 4-20 mA loop (-) FLOW 4-20 mA Signal 310-00 Calibration Port Sensor Inputs + Model 310 NOTE: Call Kele for 4000 Series wiring. Accuracy Response Time Operating Temperature Mounting 310-00 310-01 310-02 310-03 310-04 Dimensions 310-00, -04 310-01, -02, -03 Warranty Loop powered, 9-35 VDC 0.4 to 10 kHz, unscaled raw pulses from Data Industrial flow sensor, or sine wave 4-20 mA, 2-wire 750Ω @ 24 VDC A301-20 programming kit (order separately) cable connects to DIC communication port and DB9 COM port on a computer. Transmitter must be looppowered for programming (9-24 VDC will work) ±0.04% of reading over entire span Varies with filter, typically 1 second 10% to 90% step response -20° to 158°F (-29° to 70°C) Surface mount, transmitter only Surface mount, in NEMA 4X enclosure Surface mount, in metal enclosure Surface mount, in plastic enclosure DIN rail mount, with clips 1.8"H x 3.7"W x 1.5"D (4.4 x 9.3 x 3.8 cm) 2.8"H x 4.5"W x 2.0"D (7.1 x 11.3 x 5.1 cm) 1 year ORDERING INFORMATION MODEL 310 310 DESCRIPTION Programmable analog flow transmitter MOUNTING 00 Transmitter only 01 Transmitter in NEMA 4X enclosure 02 Transmitter in metal enclosure 03 Transmitter in plastic enclosure 04 Transmitter with DIN rail mount OPTIONS XR Pre-configured option 00 XR Example: 310-00-XR Preconfigured programmable analog flow transmitter for field mounting For preconfigured flow sensors, specify pipe size, schedule, and maximum flow rate at time of order. A301-20 200 Series 296 888-397-5353 USA RELATED PRODUCTSPAGE Flow/BTU transmitter programming kit, includes cable Data Industrial impeller type flow sensors with pulse output 290 kele.com WHEN YOU NEED IT RIGHT, RIGHT NOW, CALL KELE. March 2014 NEW! FLOW UNIVERSAL FLOW TRANSMITTER UFT-1 SERIES DESCRIPTION The Kele UFT-1 Series universal flow transmitter is a solidstate, digital signal converter designed to operate with Data Industrial 200 Series flow sensors. Both analog (4-20 mA) and pulse outputs are available. The UFT-1 may be mounted in an optional NEMA 4X enclosure or with digital display of gpm or totalized flow (in a non-watertight enclosure). UFT-1 FEATURES • • • • • Analog and pulse outputs Optional watertight (NEMA 4X) enclosure Optional displays for flow rate and totalization Excitation voltage for flow sensors LED indication of pulse activity UFT-1E-1 6 OPERATION APPLICATION INSTALLATION AND CALIBRATION The UFT-1 transmitter can be mounted in any position. NEMA 4X enclosed models have a watertight seal; when a display option is selected, however, the enclosure becomes non-watertight. Field calibration is not required with the UFT-1 and flow conversion must be accomplished at the monitoring computer. The information below is provided for making the conversion calculations. ANALOG OUTPUT (RATE) The UFT-1 analog transmitter converts a Data Industrial digital flow signal into a precalibrated 4-20 mA signal. It must be calibrated for each Data Industrial flow sensor installation. The pipe type, size, and maximum flow rate must be specified at the time of order if 4-20 mA output is to be used. TOTALIZED FLOW Totalized gallons = (Flow factor) x (Output divider) x (Total pulses) For totalized m3, multiply the above by 0.00379. Output divider = 10 or 100 depending on jumper-selection. Flow factors per pulse are shown in Table 1. FLOW PULSE OUTPUT (TOTALIZATION) The UFT-1 pulse output divides the Data Industrial digital flow signal by a jumper-selectable 10 or 100 to provide a more usable digital pulse. The pulse output is normally used where flow totalization is required. A simple conversion formula (using the flow factors for Data Industrial Flow Sensors on the next page) can convert the digital pulses to totalized gallons. The pulse output is an optoisolated transistor switch that can be wired to source or sink pulses to totalizer equipment. FLOW RATE Flow (gpm) = ((mA measured - 4 mA) x Maximum gpm)/16 mA. Maximum gpm is the flow rate at 20 mA output on the transmitter and must be specified at the time the UFT-1 is ordered for proper calibration. NOTE: The UFT-1 Series is not intended for field setup or field calibration. SPECIFICATIONS Supply Voltage 24 VDC Input Signal 15 to150 Hz FS, dry or electric contact Maximum Output Impedance 750Ω @ 24 VDC Output Signal UFT-1 Solid state switch; UFT-1A 4-20 mA Pulse Output 40 VDC @ 200 mA Configuration Factory configure only; provide pipe size/ schedule and maximum flow rate at time Accuracy Response Time Operating Temperature Operating Humidity Mounting UFT-1, -1A UFT-1E, -1AE Approvals Warranty of order ± 0.5% 5 seconds from 10% to 90% 32° to 140°F (0° to 60°C) 5% to 90% RH non-condensing Snap track Surface mount, enclosed RoHS 18 months WIRING Output pulse divider selection jumper (10 or 100) 100 10 Pulse out + Pulse out Totalize Pulse out – mA signal out (red) XDCR signal in 24 VDC power XDCR Sig in PWR Common Transducer power option jumper (Leave on for Data Industrial flow sensors. Remove for devices with their own power supply.) March 2014 + Flow sensor (black) + – + – Power Typical totalizer hookup + 4-20 mA – Output – 24 VDC power supply WE MAKE IT EASY. kele.com 888-397-5353 USA 297 FLOW UNIVERSAL FLOW TRANSMITTER UFT-1 SERIES DIMENSIONS NEW! FLOW FACTORS FOR DATA INDUSTRIAL FLOW SENSORS in (cm) MODEL Pulse out + Pulse out – mA signal out XDCR signal in 6 24 VDC power Common FLOW 3 .25 (8 .25) 2 .19 (5 .56) 228PV-1.5 228PV-2 228B-2 228C-2 250B-0.5 250B-0.75 250B-1 250B-1.25 250B-1.5 220B-2.5 220B 220B 220B 220B 220B 220B 220B 220B 220B 220B PIPE SIZE in (cm) FLOW FACTOR 1-1/2 (3.81) 2 (5.08) 2 (5.08) 2 (5.08) 1/2 (1.27) 3/4 (1.91) 1 (2.54) 1-1/4 (3.18) 1-1/2 (3.81) 2-1/2 (6.35) 3 (7.62) 4 (10.16) 5 (12.7) 6 (15.24) 8 (20.32) 10 (25.40) 12 (30.48) 14 (35.56) 16 (40.64) 18 (45.72) 0.03118 0.04611 0.04579 0.04731 0.005646 0.007514 0.007015 0.01280 0.01780 0.03800 0.07280 0.1396 0.2457 0.3611 0.6710 1.080 1.630 1.944 2.502 3.158 GALLONS/PULSE JUMPER IN JUMPER IN 10 POSITION 100 POSITION 0.3118 0.4611 0.4579 0.4731 0.05646 0.07514 0.07015 0.1280 0.1780 0.3800 0.7280 1.396 2.457 3.611 6.710 10.80 16.30 19.44 25.02 31.58 3.118 4.611 4.579 4.731 0.5646 0.7514 0.7015 1.280 1.780 3.800 7.280 13.96 24.57 36.11 67.10 108.0 163.0 194.4 250.2 315.8 Notes 1. Flow factors for a Model 225 and 226 are the same as Model 220. * 2. Flow factor for Model 228S is the same as 228C. 3. PV Series is sized for schedule 80 PVC pipe. All other series are sized for schedule 40 black iron pipe. ORDERING INFORMATION MODEL UFT-1 UFT-1A UFT-1E UFT-1AE UFT-1 DESCRIPTION Universal flow transmitter pulse output only Universal flow transmitter with pulse and calibrated 4-20 mA output* Universal flow transmitter pulse output in NEMA 4X enclosure Universal flow transmitter with pulse and calibrated 4-20 mA output* in NEMA 4X enclosure DISPLAY OPTION (enclosed models only,, enclosure changes to non-watertight) 1 Flow totalization only 2 Flow rate only 3 Flow totalization and flow rate** 1 maximum flow rate must be specified at time of order. ** When a UFT-1AE3 is ordered the UFT-1A will be in one enclosure and the totalizer and rate display will be in a separate enclosure. Example: UFT-1A-E-2 Basic transmitter with calibrated 4-20 mA flow rate output (4 mA = no flow; 20 mA = max flow), enclosed with LCD flow rate indication 200 Series DCP-1.5-W 298 * Pipe size, schedule, and 888-397-5353 USA RELATED PRODUCTS Data Industrial impeller type flow sensors with pulse output Power supply, 24 VAC IN to 24 VDC OUT kele.com WHEN YOU NEED IT RIGHT, RIGHT NOW, CALL KELE. PAGE 290 995 March 2014 NEW! FLOW FLOW AND ENGERY MONITOR 3000, 3050 SERIES DESCRIPTION The Badger Meter 3000 and 3050 Series flow and energy monitors are economical, full-featured, compact units designed for flow and BTU measurement applications. Outputs include one mechanical relay and one solid state pulse output, both featuring unit/pulse and set-point control independently based on flow or total readings. OPTIONAL FEATURES An analog 4-20 mA or 0-20 mA output is optional and USB, RS-485 Modbus, and BACnet/MSTP provide high-level communication. A two-line by 16-character, 3/8" high backlit LCD display is configured by the user to display flow rate and flow total. Custom units can be created during field setup. The flow sensor input features flexible scaling options and signal type selections that permit the use of most Data Industrial meter sensors, or other frequency (sine/pulse) or linear devices. Matched 10 kΩ thermistors (ordered separately) provide temperature differential for BTU calculations. 6 3050-1-0 One mechanical relay and one solid state relay output Optional 0/4-20 mA output USB, RS-485, Modbus, and BACnet/MSTP all in one unit FLOW FEATURES • Menu-driven programming or Windows based programming • NEMA 4X rated enclosure • Two-line x 16-character display • Password-restricted access • Non-volatile memory • Temperature sensor zeroing SPECIFICATIONS Supply Voltage Input 8 to 28 VAC, 5 VA; 8-35 VDC, 280 mA Data Industrial flow sensor or other frequency (sine/pulse) device Sensor Input Two 2-wire 10 kΩ type II thermistors or 100Ω 3-wire platinum RTDs or field-defined custom temperature inputs Maximum Output Impedance 1 kΩ @ 24 VDC Output Solid state pulse output rated at 1A @ 30 VAC or 35 VDC; closed 0.5Ω @ 1A; open >10 MΩ Relay Output Relay and pulse output are fully functional as either totalizing or setpoint outputs Relay Output Rating 5A @ 120 VAC or 30 VDC resistive; 1A @ 120 VAC or 30 VDC inductive Analog Output 4-20 mA, 0-20 mA (isolated, sinking or sourcing); loop powered (sinking) 30 VDC @ 0 mA maximum, 3 VDC @ 20 mA minimum; self powered (sourcing) 600Ω maximum load Pulse Rate 1 pulse per 1.0000000 to 99999999 units; any predefined or custom unit can be used for flow or BTU totalizing; contact time 1 to 9999 milliseconds Setpoints Setpoint alarm for flow rate, BTU rate, Temp1, Temp2, DeltaT using March 2014 any predefined or custom unit Compensation for variances between input sensors by adjusting T2 to match T1 Communication Interface USB 2.0A to mini-B 5-pin cable required, provides access to all programming and operation features Communication Protocol RS485 supports Modbus and BACnet/MSTP Display Backlit LCD, 16 characters/line, 0.31"H (0.79 cm), two lines Engineering Units Flow and Total in gal, liters, ft3, acre-ft, or bbl; Energy rate kBTU/ hr, BTU/min, KW, Tons, J/sec or field-programmed custom; energy total units can be MBTU, kBTU, kWh, MWh, kJ, or field-programmed custom Operating Temperature-4° to 158°F (-20° to 70°C) Enclosure Rating NEMA 4X Approvals CE Weight Panel mount 0.8 lb (0.34 kg) Wall mount 1.2 lb (0.54 kg) Warranty 1 year Zero Adjustments WE MAKE IT EASY. kele.com 888-397-5353 USA 299 NEW! FLOW FLOW AND ENGERY MONITOR 3000, 3050 SERIES WIRING Badger 3050 BTU Monitor 24 VDC Supply J1-1 Temp 1 IN+ J1-2 Temp 1 INJ1-3 Temp GND J1-4 Shield J17-3 GND J17-2 Temp 2 INJ17-1 Temp 2 IN+ J14-1 Relay 1 NO J14-2 Relay 1 NC J14-3 Relay 1 COM J13-1 Relay 1 OUT J13-2 Relay 2 OUT J6-1 Analog IN+ J6-2 Analog INJ6-3 Shield J8-1 Sensor IN J8-2 GND J8-3 Shield J8-4 Sensor Power 4-20 mA J9-3 GND (red) 10 K Type II Thermistor (black) bare wire 10 K Type II Thermistor J10-1 RS485 A J10-2 RS485 B J10-3 RS485 Iso GND J9-1 Loop+ J9-2 Loop- Pulse Counter DC Power J12-1 USB Power J12-2 USB DataJ12-3 USB Data+ J12-4 N/C J12-5 Shield USB Connection 200 Series Flow Sensor 6 J1-1 Earth J1-2 ACC/DC J1-3 ACL/DC + 12-24 VDC/VAC Power Supply DIMENSIONS 4.33" 110 mm FLOW 3.57"-3.60" 90.6 mm-91.4 mm 1/8" 3.2 mm (4 PLACES) 3.54" 90 mm 3.49" 88.7 mm MOUNTING TEMPLATE PANEL CUTOUT 2.21" 56 mm TOP 3.57"-3.60" 90.6 mm-91.4 mm 4.80" 122 mm 3.78" 96 mm 3.23" 82 mm Data ® Industrial Data ® Industrial Series 3050 Series 3050 SIDE 3.78" 96 mm 3.62" 92 mm 3.49" 88.7 mm 4.72" 120 mm SIDE ORDERING INFORMATION MODEL 3000 3050 200 Series ST-U24B-XP ST-U24S-XP 300 888-397-5353 USA DESCRIPTION Flow meter with display BTU monitor with display ANALOG OUTPUTS 0 No analog output 1 Analog output, RS485 (BACnet/Modbus), and USB MOUNTING 0 Panel mount 1 Wall mount RELATED PRODUCTS PAGE Data Industrial impeller type flow sensors with pulse output 290 Temperature sensors, matched ±0.1°F, brass wells Temperature sensors, matched ±0.1°F, stainless steel wells kele.com WHEN YOU NEED IT RIGHT, RIGHT NOW, CALL KELE. March 2014 NEW! FLOW ULTRASONIC FLOWMETER DTFXL SERIES DESCRIPTION The Dynasonics DTFXL Series ultrasonic flow meter measures water flow in a wide variety of pipe sizes and pipe materials, using clamp-on sensors that attach to the outside of the pipe. This non-invasive, non-contact flow meter provides instantaneous flow rate and accumulated flow and provides a 4-20 mA output as well as pulse outputs. The DTFXL Series flow meter is easy to install, has a large bidirectional flow range, and comes with or without a display. Configuration, monitoring, and calibration of the DTXFL is accomplished with an easy-to-use software package via a cable connection from a PC to the flow meter. For systems using water/glycol solutions, the higher-powered DB Series ultrasonic flow meter may perform better. FEATURES Transit-time technology in an economical package Can handle some suspended solids and gas pockets Bidirectional flow range for changeover systems Multiple totalizers for forward, reverse, net Models with or without display Selectable standard or metric engineering units Non-invasive, no system down time to install 4-20 mA output plus choice of pulse outputs Optional armored cable High temperature transducers available 6 APPLICATION The DTFXL Series is available in 3 basic transmitter/ transducer arrangements for installation and application flexibility. Models with integral transducers are available for pipe sizes 1/2" to 2"; the transmitter is attached to the transducers which clamp on to the pipe for a local mount arrangement. Models with remote small pipe (1/2" to 2") clamp-on transducers require the transmitter to be wall- or panelmounted away from the pipe. FLOW • • • • • • • • • • DTFXL4-AN1-NN Models with remote large pipe (2-1/2" to 100") strap-on transducers also require the transmitter to be wall or panelmounted away from the pipe. Transmitters are available with or without display. SPECIFICATIONS Supply Voltage Frequency 11 to 30 VDC 0-1000 Hz for Turbine output (nonground referenced AC and 100 mV pp minimum), switch selectable; 5 VDC pp ground-referenced square wave for TTL output Supply Current 0.25 A Maximum Output Impedance 900Ω maximum for 4-20 mA output; source power can share common with power supply Outputs 4-20 mA and Turbine or TTL Conduit Opening 1/2" conduit knockout (7/8" hole, 2.2 cm) Cable Length Remote transducer models available with 20' (6.1m), 50' (15m), or 100' (30m) cables Accuracy ± 1.0% of reading above 1 fps (0.3 mps) velocity, ± 0.01% of reading below 1 fps (0.3 mps) Response Time 0.3 to 30 seconds, adjustable March 2014 Display Two-line x eight-character LCD Operating Temperature-40° to 185°F (-40° to 85°C); remote DTTS/DTTN transducers have upper limit of 250°F (121°C) and high temperature DTTH transducers have upper limit of 400°F (200°C) Velocity Range 0.1 to 40 fps (feet/second), 0.03 to 12.4 mps (meters/second), bi-directional Pipe Size Range 1/2" to 100" (1.2 to 254 cm) Media Compatibility Most clean liquids or liquids with some suspended solids or aeration, not recommended for glycol solutions, not for steam; for water/ glycol systems the DE Series is recommended Enclosure Rating NEMA 4X as long as a liquid-tight connector is used Approvals ANSI/ISA 582.01; CSA C22.2 No. 213, E79-15-95 Warranty 1 year WE MAKE IT EASY. kele.com 888-397-5353 USA 301 FLOW ULTRASONIC FLOWMETER DTFXL SERIES in (mm) PC cable connection Note: Power ground and 4-20 mA common are connected internally. Upstream (red) Upstream (black) Downstream (black) Downstream red) NEW! DIMENSIONS- INTEGRAL MODELS WIRING Transducer connections 6.66 (169.2) TRANSIT TIME FLOWMETER – 4-20 mA + 4-20 mA output – + Turbine or TTL output Turbine or TTL Pulse Power – + + – 24 VDC power supply 3.17 (80.5) 2.57 (65.3) 0.875 (22.2) diameter conduit hole B Note: Integral model transmitters have conduit knockout connection on the right side of the enclosure. Remote models have two conduit holes on the bottom side of the enclosure. D A C Dimensions A, B, C and D vary by pipe size, the D dimension being slightly larger than the outside diameter of the pipe. 6 ORDERING INFORMATION FLOW MODEL DTFXL1 DTFXL2 DTFXL3 DTFXL4 Remote transducers for small pipes (with “Y” pipe size) DESCRIPTION Transmitter without display Transmitter with display Transmitter without display, UL enclosure Transmitter with display, UL enclosure PIPE SIZE A 1/2" ANSI carbon steel B 3/4" ANSI carbon steel C 1" ANSI carbon steel D 1 1/4" ANSI carbon steel E 1 1/2" ANSI carbon steel F 2" ANSI carbon steel G 1/2" copper H 3/4" copper I 1" copper J 1 1/4" copper K 1 1/2" copper L 2" copper M 1/2" tubing (plastic) N 3/4" tubing (plastic) P 1" tubing (plastic) Q 1 1/4" tubing (plastic) R 1 1/2" tubing (plastic) S 2" tubing X For DTTN, DTTH transducers Y MODEL DESCRIPTION DTTS Remote transducers for 1/2" to 2" pipes DTTC High Temperature transducer for 1/2” to 2” pipes PIPE SIZE D 1/2" F 3/4" G 1" H 1 1/4" J 1 1/2" L 2" PIPE TYPE P ANSI carbon steel C Copper T Tubing CABLE LENGTH 020 20 feet (6.1 m) 050 50 feet (15 m) 100 100 feet (30 m) CABLE ARMOR OPTION N No armor A Flexible armor CABLE ARMOR LENGTH 000 No armor 020 20 feet (6.1 m) 050 50 feet (15 m) 100 100 feet (30 m) For DTTS, DTTC transducers CONNECTOR OPTIONS N 1/2" conduit knockout OUTPUT SIGNALS 1-NN 4-20 mA and pulse D002-2007-001 D005-0803-104 D005-2116-004 D010-0204-001 D010-2102-010 DCP-1.5-W DCPA-1.2 302 888-397-5353 USA Remote transducers for large pipes (with “X” pipe size) MODEL DESCRIPTION DTTN Standard transducer for 2 1/2" to 20" pipes DTTH High temperature transducer for 2 1/2" to 100" pipes CABLE LENGTH 020 20 feet (6.1 m) 050 50 feet (15 m) 100 100 feet (30 m) CABLE ARMOR OPTION N No armor A Flexible armor CABLE ARMOR LENGTH 000 No armor 020 20 feet (6.1 m) 050 50 feet (15 m) 100 100 feet (30 m) OPTIONS N Normal area rating NOTE: Add -C suffix to transmitter model number for factory-configured transmitter and fill out the application data sheet located on Kele's website. The UltraLink software is required to reset the DTFXL totalizer and to field configure, monitor, and diagnose the DTFXL. The PC cable is required to connect a PC to the DTFXL and the software is available on CD or free from www.dynasonics.com. RELATED PRODUCTS Additional 36" stainless straps for DTTN/H transducers (two straps included standard with remote transducers) UltraLink software CD USB to DB-9 Serial Communications Cable PC to transmitter cable Mounting track assembly for DTTN/DTTH transducers, for <10" pipes Power supply, 24 VAC IN to 24 VDC OUT Power supply, 120 VAC IN to 24 VAC/24 VDC OUT kele.com WHEN YOU NEED IT RIGHT, RIGHT NOW, CALL KELE. PAGE 995 994 March 2014 NEW! FLOW MAGNETIC FLOW METER M-2000 SERIES DESCRIPTION The Badger Meter M-2000 Series magnetic flow meter is the result of years of research and field use in electromagnetic flow meters. The M-2000 can measure almost any liquid, slurry or paste that has minimum electrical conductivity. These meters are perfect for flow measurement in commercial HVAC water systems, wastewater, reclaimed water, irrigation and industrial applications because they can handle suspended solids, have no pressure drop, no moving parts, and their accuracy is not affected by temperature, pressure, viscosity, density or flow profile. They are NSF listed for use in potable water. The ANSI 150 RF flanged pipe spool makes them easy to install and they are available with the NEMA 4X (IP66) integral amplifier (transmitter and display housing) mounted atop the flow detector housing, or with the amplifier remotely mounted. For the remote mount configuration, a 30 ft. cable is standard (other lengths available) and the detector housing comes with either a NEMA 4X or NEMA 6P (submersible) junction box. Each meter is factory calibrated and tested and a certificate is included. • Empty pipe detection feature generates error message when pipe is not full • NEMA 4X (IP66) enclosure for installation in exposed areas • Large backlit 4-line, 20 character LCD display for local indication and programming even in low light conditions • Modbus RTU via RS232 communications for network systems FLOW FEATURES • High accuracy of +/- 0.25% and flow range of 300:1 for reliable measurement • Unaffected by most solids contained in the fluid for application flexibility • Pulsed DC magnetic field for zero point stability • Corrosion resistant liners provide long life • Grounding rings included for non-conductive piping • Bidirectional flow sensing and totalization for reversing system application 6 SPECIFICATIONS Supply Voltage Supply Watts Digital Inputs Maximum Output Impedance Outputs Analog output Digital outputs Pulse outputs Frequency output Alarm Wiring Terminations Communication Accuracy Repeatability Display March 2014 85-265 VAC (45-65 Hz) 15 W Maximum 30 VDC, programmable as positive zero return, external totalizer reset, or preset batch start 800 ohms @ 24 VDC 0-20 mA, 4-20 mA, 0-10 mA, or 2-10 mA Four configurable, 24 VDC sourcing outputs (maximum of two) 50 mA each or 100 mA total, sinking open collector outputs (maximum of four) 100 mA each or 30 VDC total, AC solid state relay (maximum of two) 48 VAC 500 mA maximum Scalable up to 10 kHz, passive open collector up to 10 kHz active switched 24 VDC, up to two outputs (forward and reverse flow), pulse width programmable from 1 to 1,000 ms or 50% duty cycle Scaleable up to 10 kHz open collector, up to 1 kHz solid state relay High/low flow alarm, error alarm, empty pipe alarm outputs 1/2" NPT conduit connection and 3 cord grips on amplifier housing; 30 ft. standard length cable for remote mount configurations (other lengths available) RS232 - Modbus RTU or remote display ±0.25% of flow rate for velocities greater than 1.64 fps (0.5 mps; ±0.004% for lower velocities ±0.1% Backlit, 4 line, 20 character LCD and 3-button progamming keys Engineering Units Pipe Size Range Flow Range Velocity Range Operating Temperature Operating Humidity Media Compatibility Media Temperature Range Maximum Pressure Materials Of Construction Enclosure Rating Approvals Warranty WE MAKE IT EASY. Ounces, pounds, liters, US gallons, imperial gallons, barrels, hectoliters, megagallons, cubic meters, cubic feet, acre feet 1" to 24" standard (1/4", 1/2" and 28" to 54" also available), ANSI 150 RF flanges standard Unidirectional or bidirectional with two separate totalizers (programmable) 0.10 to 39.4 fps (0.03 to 12 mps) -4° to 140°F (-20° to 60°C) Up to 90% non-condensing Many fluid applications including hot or chilled water, glycol solutions; minimum conductivity 5.0 µΩ/cm 178°F (80°C) with rubber liner; 212°F (100°C) with PTFE liner and local mount amp; 311°F (155°C) with PTFE liner and remote mount amp 285 psig at ambient temperature, refer to ANSI B16.5 standard for 150 lb RF flanges for temperature/pressure spec Meter housing and flanges: carbon steel Liner: Rubber Electrodes: Alloy C Pipe spool: 316 SS Grounding rings: stainless steel Amplifier housing: cast aluminum with powder-coat paint NEMA 4X (IP66) amplifier housing; NEMA 4X or NEMA 6P detector housing junction box for remote mount configuration NSF Listed, CE 1 year kele.com 888-397-5353 USA 303 FLOW MAGNETIC FLOW METER M-2000 SERIES WIRING NEW! FLOW 6 304 888-397-5353 USA kele.com WHEN YOU NEED IT RIGHT, RIGHT NOW, CALL KELE. March 2014 NEW! FLOW MAGNETIC FLOWMETER M-2000 SERIES DIMENSIONS Note: Dimension D in table below is overall height (similar to dimension B) to the top of junction box, for assemblies with remote amplifier configuration. 6 DIMENSIONS AND FLOW RANGES A B C D Weight Flow Range 1" (DN25) 8.9" (22.5 cm) 14.4" (36.6 cm) 4.3" (10.8 cm) 11.7" (29.8 cm) 18 lb (8.0 kg) 0.3 to 93 gpm (1.2 to 350 lpm) 1-1/4" (DN32) 8.9" (22.5 cm) 15.2" (38.6 cm) 4.6" (11.7 cm) 12.5" (31.8 cm) 20 lb (9.0 kg) 0.5 to 150 gpm (2.0 to 575 lpm) 1-1/2" (DN40) 8.9" (22.5 cm) 15.4" (39.0 cm) 5.0" (12.7 cm) 12.7" (32.2 cm) 21 lb (9.5 kg) 0.8 to 239 gpm (3 to 900 lpm) 2" (DN50) 8.9" (22.5 cm) 15.9" (40.3 cm) 6.0" (15.2 cm) 13.2" (33.5 cm) 26 lb (11.5 kg) 1 to 373 gpm (4.7 to 1400 lpm) 2-1/2" (DN65) 11.0" (28.0 cm) 17.1" (43.4 cm) 7.0" (17.8 cm) 14.4" (36.6 cm) 52 lb (23.5 kg) 2 to 631 gpm (8 to 2400 lpm) 3" (DN80) 11.0" (28.0 cm) 17.3" (44.0 cm) 7.5" (19.1 cm) 14.7" (37.2 cm) 54 lb (24.5 kg) 3 to 956 gpm (12 to 3600 lpm) 4" (DN100) 11.0" (28.0 cm) 18.4" (46.6 cm) 9.0" (22.9 cm) 15.7" (39.8 cm) 56 lb (25.5 kg) 5 to 1493 gpm (19 to 5600 lpm) 5" (DN125) 15.8" (40.0 cm) 19.6" (49.8 cm) 10.0" (25.4 cm) 16.9" (43.0 cm) 58 lb (26.0 kg) 8 to 2334 gpm (30 to 8800 lpm) 6" (DN150) 15.8" (40.0 cm) 20.6" (52.4 cm) 11.0" (27.9 cm) 17.9" (45.6 cm) 60 lb (27.0 kg) 11 to 3361 gpm (40 to 12,700 lpm) 8" (DN200) 15.8" (40.0 cm) 22.5" (57.2 cm) 13.5" (34.3 cm) 20.4" (51.8 cm) 86 lb (39.0 kg) 20 to 5975 gpm (75 to 22,600 lpm) 10" (DN250) 19.7" (50.0 cm) 26.8" (68.1 cm) 16.0" (40.6 cm) 24.1" (61.3 cm) 178 lb (81 kg) 30 to 9336 gpm (120 to 35,300 lpm) 12" (DN300) 19.7" (50.0 cm) 28.9" (73.4 cm) 19.0" (48.3 cm) 26.2" (66.6 cm) 207 lb (94 kg) 45 to 13,444 gpm (170 to 50,800 lpm) 14" (DN350) 19.7" (50.0 cm) 30.8" (78.2 cm) 21.0" (53.3 cm) 28.2" (71.6 cm) 258 lb (117 kg) 60 to 18,299 gpm (230 to 69,200 lpm) 16" (DN400) 23.6" (59.0 cm) 33.7" (85.6 cm) 23.5" (59.7 cm) 31.0" (78.8 cm) 306 lb (139 kg) 80 to 23,901 gpm (300 to 90,400 lpm) 18" (DN450) 23.6" (59.0 cm) 35.0" (89.0 cm) 25.0" (63.5 cm) 32.4" (82.2 cm) 400 lb (181 kg) 100 to 30,250 gpm (380 to 114,000 lpm) 20" (DN500) 23.6" (59.0 cm) 38.2" (96.9 cm) 27.5" (69.9 cm) 35.5" (90.1 cm) 493 lb (224 kg) 125 to 37,346 gpm (470 to 140,000 lpm) 22" (DN550) 23.6" (59.0 cm) 39.6" (100 cm) 29.5" (74.9 cm) 36.9" (93.7 cm) 523 lb (237 kg) 150 to 45,188 gpm (570 to 170,000 lpm) 24" (DN600) 23.6" (59.0 cm) 42.2" (107 cm) 32.0" (81.3 cm) 39.5" (100 cm) 552 lb (251 kg) 180 to 53,778 gpm (680 to 200,000 lpm) March 2014 WE MAKE IT EASY. kele.com 888-397-5353 USA FLOW Size 305 NEW! FLOW MAGNETIC FLOWMETER M-2000 SERIES APPLICATION AND INSTALLATION The M-2000 provides two amplifier mounting options, integral or remote. The amplifier housing is NEMA 4X rated and can be located outdoors; observe the operating temperature range of -4° to 140°F (-20° to 60°C). If located outdoors, provide a roof or shield over the amplifier to protect the LCD display from direct sunlight. If the amplifier is to be remote mounted, standard available cable lengths are 15', 30', 50' and 100' (up to 500' optional). Magnetic flowmeters can operate accurately in any pipeline orientation and can measure flow in both directions. A "Forward Flow" direction arrow is printed on the detector label. They also perform best when placed in a vertical pipe with the liquid flowing upward; this assures a full pipe at all times and minimizes sediment deposits on the liner and electrodes. If mounting in a horizontal pipe, mount the detector such that the electrodes are on the sides of the pipe, not the top and bottom, also to minimize deposits and build-up on the electrodes. Avoid locations where a partially-filled piping situation can occur; the meter will display an "Empty Pipe Detection" message and will stop measuring flow until the pipe is full. 6 Sufficient straight-pipe runs are required for optimum accuracy and performance. A minimum of 3 diameters upstream and 2 diameters downstream are required (more is better). Grounding is critical for magnetic flow meters; they must be electrically connected to the liquid media. If using non-conductive piping, the grounding rings (included) must be properly installed. See the M-2000 manual for details. FLOW ORDERING INFORMATION MODEL DESCRIPTION M2K- Magnetic flowmeter SIZE CODE PIPE SIZE 010 1" 013 1-1/4" 015 1-1/2" 020 2" 025 2-1/2" 030 3" 040 4" 050 5" 060 6" 080 8" 100 10" 120 12" 140 14" 160 16" 180 18" 200 20" 220 22" 240 24" LINER CODE LINER MATERIAL RRubber TPTFE AMPLIFIER OPTIONS LC Local mount amplifier, NEMA 4X (IP66) housing RM-N4X Remote mount amp, 30 ft. cable, NEMA 4X junction box on detector tube RM-N6P Remote mount amp, 30 ft. cable, NEMA 6P junction box on detector tube M2K- 306 040 888-397-5353 USA R- kele.com LC Example: M2K-040R-LC 4" magnetic flowmeter with rubber liner, local mount amplifier WHEN YOU NEED IT RIGHT, RIGHT NOW, CALL KELE. March 2014 NEW! FLOW FIXED AND RETRACTABLE INSERTION VORTEX FLOW METERS 2200, 3100 SERIES DESCRIPTION The 2200 Series fixed insertion and 3100 Series retractable vortex flow meters are used to measure the flow rate of water or water/glycol mixtures in 2" to 20" pipes. Each flow meter is factory calibrated and scaled to provide precise output signals. No complex field adjustments or confusing measurement routines are required to install the flow meters. Simple design, easy installation, reliable performance, and low cost make these flow meters an excellent choice for commercial HVAC applications. FEATURES • No moving parts • Easy to install • Reliable and robust design • Wide flow range - 15:1 turndown ratio • Microprocessor based piezo resistive sensor technology • Optional integral display FIGURE 1. VORTICES CREATED BY A BLUFF BODY FIGURE 2. EXAMPLES OF VORTEX EFFECT Bluff body OPERATION As flow passes a bluff body in the flow stream, vortices are alternately formed on either side of the bluff body (Figure 1). According to well-proven physical laws, the frequency at which vortices are alternately formed is directly proportional to the average flow velocity. The vortices create low- and high-pressure zones behind the bluff body. A vortex flow meter has a sensing element that detects these low- and high-pressure zones and the frequency at which they are created to measure flow. The fluttering of a flag (Figure 2) is one example of how vortices are created. The flag pole acts as a bluff body to the blowing wind as the flag waves from the force of the vortices alternately created. 6 FLOW Bluff body 2200 Series with optional display and Thredolet® mount SPECIFICATIONS Supply Voltage 10-32 VDC Maximum Output Impedance R(load) = 50 (Vs-10) Output Signal 4-20 mA loop-powered standard (pulse output available special order) Connections 2200: 1-1/2" MNPT 3100: 2" MNPT Wiring Terminations Screw terminals inside housing Conduit Connection 3/4" FNPT Configuration For factory pre-configuration, specify pipe size, pipe material/schedule and maximum flow rate. Separately available Hydro-Flow Field-Pro software is available for field configuration Accuracy ± 1% of full scale (combined linearity and repeatability) Display Optional, LCD alternates between showing 4-digit flow rate and 8-digit total flow Engineering Units English, gallons; metric, cubic meters (other units available upon request or can be configured using Hydro-Flow Field-Pro software) Operating Temperature-20° to 140°F (-29° to 60°C) Velocity Range 1 fps (0.3 mps) minimum, 15 fps (4.5 mps) maximum March 2014 Pipe Size Range Installation 2200: 2" to 20" (5 to 50 cm) 3100: 3" to 20" (8 to 50 cm) Install in straight pipe section with a minimum distance of 10 pipe diameters upstream and 5 pipe diameters downstream to any bend, obstruction or transition Mounting Thredolet®, or piping tee (2200 Series only) Media Compatibility Water, water/glycol mixtures, condensate Media Temperature Range 32° to 160°F (0° to 71°C) Maximum Pressure 400 psig (2759 kPa) for Thredolet® mount, 150 psig (1035 kPa) for piping tee mount Materials Of Construction Reinforced polycarbonate enclosure, Ultem® plastic vortex shedder, 316 SS shedder bar, stainless steel stem, EPDM o-rings, brass compression fitting, aluminum/nickel-plated retractor (3300 Series only) Enclosure Rating NEMA 6 Warranty 2 years WE MAKE IT EASY. kele.com 888-397-5353 USA 307 NEW! FLOW FIXED AND RETRACTABLE INSERTION VORTEX FLOW METERS 2200, 3100 SERIES WIRING Vs (10 to 32 VDC) *Rload 4-20 mA wiring * Rload maximum = 50 (Vs - 10) 6 FLOW RANGES Pipe size in (mm) FLOW Minimum flow 2200 gpm (m3/h) Series Maximum flow gpm (m3/h) Minimum flow 3100 gpm (m3/h) Series Maximum flow gpm (m3/h) 2" (50) 3" (80) 4" (100) 6" (150) 8" (200) 10" (250) 12" (300) 14" (350) 16" (400) 10.6 (2.4) 23.4 (5.4) 40 (9.2) 100 (23) 167 (38) 267 (61) 368 (83) 418 (95) 568 (129) 734 (167) 934 (212) 160 (36.3) 350 (79.5) 18" (450) 20" (500) 600 (136) 1500 (341) 2500 (557) 4000 (909) 5500 (1249) 6250 (1420) 8500 (1931) 11000 (2498) 14000 (3180) N/A 26.6 (6.0) 40 (9.0) 100 (23) 167 (38) 267 (61) 366 (83) 417 (95) 567 (129) 733 (167) 933 (212) N/A 400 (90.8) 600 (136) 1500 (341) 2500 (557) 4000 (909) 5500 (1249) 6250 (1420) 8500 (1931) 11000 (2498) 14000 (3180) ORDERING INFORMATION MODEL 2200 3100 DESCRIPTION Fixed insertion vortex flow meter Retractable insertion vortex flow meter PIPE SIZE DESCRIPTION 02 2" pipe (fixed insertion only) 03 3" pipe 04 4" pipe 06 6" pipe 08 8" pipe 10 10" pipe 12 12" pipe 14 14" pipe 16 16" pipe 18 18" pipe 20 20" pipe MOUNTING DESCRIPTION 1 Thredolet® 4 Tee (2" size only) OUTPUT, DISPLAY OPTIONS DESCRIPTION 2-1-1 4-20 mA output, no display 2-2-1 4-20 mA output, display, English units 2200 06 2-1-1 1 Example: 2200-06-1-2-1-1 Fixed insertion flow meter, 6" pipe, Thredolet® mount, 4-20 mA, no display Notes: Other options and configurations available. Separately ordered configuration software also available for field configuration. Consult Kele with calibration information when ordering (pipe size, fluid temperature and pressure, max flow rate). Software - FieldPro - EC10011 308 888-397-5353 USA kele.com WHEN YOU NEED IT RIGHT, RIGHT NOW, CALL KELE. March 2014 NEW! FLOW INSERTION VORTEX FLOW METER V-BAR 700 DESCRIPTION The V-Bar 700 insertion vortex flow meter can be used to measure the flow rates of most liquids, gases, and steam. The same V-Bar 700 will fit pipe sizes from 3" to 80" (8 to 200 cm), features no moving parts, adds negligible head loss to the system, and comes with an easily programmable integral local flow rate indicator and totalizer. The microprocessorbased electronics condition the signal and provide a frequency output, a scaled pulse output, or a 4-20 mA output. OPERATION Vortex flow meters are devices that measure the frequency of vortices created in the flow stream. Vortices are like tiny eddies produced by an obstruction (called a bluff body) in the flow and are actually areas of low pressure. These vortices travel with the flow downstream until they run out of energy. Inserting a bluff body (Figure 1) into the stream creates these vortices that alternate from side to side. The frequency of these vortices or pressure pulses can be measured and are directly proportional to the average flow rate. A flag waving in the wind is an example of this vortex effect (Figure 2). The flagpole is the bluff body, and the high- and low-pressure areas are seen as high and low ridges in the flag. These ridges alternate as they travel across the flag and cause the flag to appear to be waving. FEATURES • Measures flow rates of liquids, gases, or steam • 2000 psig (13,790 kPa) pressure rating • 500°F temperature rating • No moving parts • Integral transmitter with local display • Stainless steel construction 6 FIGURE 1. VORTICES CREATED BY A BLUFF BODY FIGURE 2. EXAMPLES OF VORTEX EFFECT FLOW Bluff body Bluff body SPECIFICATIONS Supply Voltage Isolated 18-40 VDC Supply Current 35 mA maximum Maximum Output Impedance R(load) = 50 (Vs-18) Output Signal 4-20 mA two-wire loop-powered, scalable frequency voltage pulse (3-wire 0-3000 Hz square wave, 50% duty cycle, low level = 0-1 V, high level = power supply voltage-load) Connections 2" MNPT process connection, 1/4" pressure tap Wiring Terminations Screw terminals inside housing Conduit Connection 3/4" FNPT Configuration Factory pre-configuration required, see Ordering Information Accuracy ± 1.0% of flow rate for water applications, ± 1.5% of flow rate for steam and gas Repeatability ± 0.15% of flow rate Response Time Adjustable from 1 to 100 seconds Display 2-line by 8-character LCD alternately shows flow rate and total flow. Four-button interface enables local programming modifications Engineering Units English, gallons; metric, cubic meters (other units available upon request) Operating Temperature Operating Humidity Velocity Range -20° to 140°F (-29° to 60°C) 5 to 100% RH non-condensing Liquid flow: 1.5 fps (0.5 mps) minimum, 32 fps (9 mps) maximum Pipe Size Range 3" to 80" (8 to 200 cm) Installation Straight pipe section, minimum 10 pipe diameters upstream, 5 pipe diameters downstream Mounting Thredolet®, or piping tee Media Compatibility Liquid, gas or steam Media Temperature Range-200° to 500°F (-129° to 260°C) Maximum Pressure 2000 psig (138 bar) Materials Of Construction Wetted parts: 316 stainless steel (or cast equivalent) External parts: Aluminum, 316 SS, carbon steel Electrical enclosure: 383 Aluminum Enclosure Rating NEMA 4X Dimensions Maximum overall height 32.5" (82.6 cm); insertion 3" minimum to 10" maximum (7.6 to 25.4 cm), recommended service clearance 12" (30.5 cm) Weight 9 lb (4.1 kg) maximum Warranty 2 years ORDERING INFORMATION Please call Kele for specific application and prices. The following information is required: March 2014 1. Pipe size and schedule 2. Type of gas or liquid 3. Operating pressure 4. Maximum flow rate (lb/hr, scfm) 5. Temperature 6. Constant or varying pressure WE MAKE IT EASY. kele.com 888-397-5353 USA 309 FLOW TARGET FLOW METER NFP SERIES DESCRIPTION 6 The Niagara NFP Series ForceMeter™ is an insertion type flow meter that can measure water or steam. It utilizes a hermetically sealed strain-gage bridge circuit to convert flow force to a two-wire 4-20 mA output signal that is proportional to flow rate. All wetted parts are 316L stainless steel and the meter mounts to 4" and larger pipes using a 2" or 4" ANSI 150# or 300# raised face flange. The NFP Series comes pre-calibrated and configured based on the application parameters provided at the time of order; the meter only needs to be zeroed to adjust for installation orientation. Many different models and configuration options are available, such as retractable insertion types, inline models, and hazardous approval. NEW! FLOW FEATURES C FM US APPROVED • Quick response time for flow change display in less than 1 second, can be dampened • Rugged design includes no moving parts to wear out • All welded sensor construction for durability • Hermetically sealed to withstand challenging environmental conditions • Maintenance-free keeps cost of ownership down • Integral display for local indication of flow and totalization NFP Series SPECIFICATIONS Supply Voltage Output Signal Accuracy Repeatability Response Time Display Wiring Terminations Conduit Connection Configuration Flow Range Pipe Size Range Turn Down Installation 310 24 VDC ±10% 2-wire, 4-20 mA @ 500Ω ± 1.0% of rate ± 0.15% of flow rate 0.33 mS 2-line alphanumeric with bar graph Screw terminals 3/4" FNPT Factory pre-configuration required to assure application/product match: specify pipe size and material/ schedule, fluid/gas type, operating pressure and temperatures, and minimum/maximum flow rates 19.6 gpm (4" pipe) to 98,000 gpm (60" pipe) 4" to 60" (100 to 1500 cm) 15:1 Install in straight pipe section with a minimum distance of 10 pipe diameters upstream and 5 pipe diameters downstream to any bend, obstruction or transition 888-397-5353 USA kele.com Mounting ANSI flanges standard Media Compatibility Liquid, non-volatile gases, or steam Media Temperature Range -65° to 425°F (-54° to 218°C), other ranges special order Operating Temperature-4° to 170°F (-20° to 75°C) Maximum Pressure >1000 psi (69 bar) for primary sensing elements; piping connections per applicable ANSI specs Materials Of Construction 316L stainless steel wetted parts, Polyester powder coated aluminum housing Enclosure Rating NEMA 4X Dimensions Height 10.8" (32.4 cm) from mounting flange to top of transmitter; insertion length depends on pipe size specified, force sensor locates in center of pipe Approvals CE, FM Weight 9 lb (4.1 kg) maximum Warranty 2 years WHEN YOU NEED IT RIGHT, RIGHT NOW, CALL KELE. March 2014 NEW! FLOW TARGET FLOW METER NFP SERIES WIRING DIMENSIONS Typical Remote Enclosure Integral Transmitter Wiring Enclosure Mounted on Flowmeter (Backside) Conduit Entry for Customer Wiring 4.5 (11.4) Conduit Entry for Customer Wiring GND + – 8.25 (20.96) (approx.) Customer Wiring 4-20mA Output + – 6 4 (10.2) Power Supply 18-36 VDC + – BAS – E + L FLOW 6.0 (15.2) Flow Typical Integral Enclosure ORDERING INFORMATION MODEL DESCRIPTION NFP Flow Meter LINE SIZE (inches) DESCRIPTION 4, 5, 6, 8, 10, 12, etc. Select pipe size (larger insertion and smaller in-line models are available) MOUNTING DESCRIPTION M 2" raised flange P 4" raised flange FLANGE RATING DESCRIPTION 01 150 # raised-face ANSI 02 300 # raised-face ANSI BODY, ELEMENT DESCRIPTION Y1V1ZV SS316L Body, unidirectional Gas, Liquid or Steam G, L, or S NFP 4 M 01 Y1V1ZV 5.5 (13.97) G Example: NFP-4-M-01-Y1V1ZV-G Insertion target flow meter for water, 4" pipe size, 2" RF 150 # mounting flange, 303/304 SS body, 1,000 psi, 425 DF -rating DCPA-1.2 DCP-1.5-W March 2014 RELATED PRODUCTSPAGE Power supply, 120 VAC IN to 24 VAC/24 VDC OUT 994 Power supply, 24 VAC IN to 24 VDC OUT 995 WE MAKE IT EASY. kele.com 888-397-5353 USA 311 FLOW BTU TRANSMITTER 340 SERIES DESCRIPTION The Badger Meter 340 Series is an inexpensive and easy-toapply BTU transmitter which calculates energy usage based on liquid flow rate from a Data Industrial impeller flow sensor and differential temperature using two 10 kΩ thermistor inputs. The onboard microcontroller and digital circuitry provide precise measurements and produce accurate driftfree outputs. Configuration is accomplished with a Windows® based software programming kit. The 340 Series is available with onboard communication technology for LonWorks, BACnet, Johnson Controls N2 Metasys, or Modbus networks. NEW! 6 FEATURES AC or DC powered for installation flexibility Field programmable makes changes easy Small footprint saves space Uses two matched 10Ωk thermistors Used with Data Industrial flow sensors 340-00 FLOW • • • • • SPECIFICATIONS Supply Voltage Supply Current Input Signal Output Signal -- Output BN Output LW Output N2 Output Pulse Output 312 12-35 VAC ±5% or 12-24 VDC ±10% 60 mA @ 12 VDC All flow sensors: Excitation voltage 3-wire, 7.9-11.4 VDC, 270Ω source impedance Pulse sensors: Signal amplitude 2.5 VDC threshold, signal limit <35V AC or DC peak, frequency 0-10 kHz, pull-up 8.5 VDC @ 2 kΩ source impedance Sine wave sensors: Signal amplitude 10 mV p-p threshold, signal limit <35V AC or DC peak, frequency 0-10 kHz Temperature sensors: Two matched 10 kΩ @ 25°C, two-wire, type II Pulse, isolated solid state switch programmed for units of energy or flow BACnet and Modbus communication LonWorks communication N2 communication Voltage range: 0 to ±60V (DC or AC peak); On-state load current: 700 mA maximum; On-state load resistance: 700 mΩ; Off-state leakage: < 1µA @ 60 V peak; Pulse width: adjustable from .05 to 5.0 seconds 888-397-5353 USA kele.com User Interface Communication Configuration Computer connection allows visibility of real-time flow rate, flow total, temperature readings, energy rate and energy total BACnet and Modbus, LonWorks, Metasys N2, or Modbus Windows® based A30120 programming kit (order separately) cable connects to DIC communication port and DB9 COM port on a computer for calibration of flow sensor information, units, output scaling; unit must be powered to configure Mounting -00 Enclosure Surface mount, no enclosure -02 Enclosure Surface mount, in metal enclosure -03 Enclosure Surface mount, in plastic enclosure -04 Enclosure DIN rail mount, with clips Operating Temperature-20° to 158°F (-29° to 70°C) Weight 0.3 lb (0.14 kg) without enclosure Warranty 1 year WHEN YOU NEED IT RIGHT, RIGHT NOW, CALL KELE. March 2014 NEW! WIRING Pulse input device BTU TRANSMITTER 340 SERIES DIMENSIONS in (cm) (–) (+) AC/DC power + supply – Flow Sensor FLOW 1.6 (4.1) Pulse – AC Line or DC+ AC Common or DC– output + 3.65 (9.3) Power out Signal (+) Signal (–) Shield (red) (black) 0.88 (2.2) Shield (if applicable) 6 2.95 (7.5) Temp 1 0.6 (1.5) Temperature sensors Temp 2 * Network communications terminals vary slightly per model FLOW ORDERING INFORMATION MODEL DESCRIPTION 340 BTU meter OUTPUT LW Transmitter for use with LONWorks networks N2 Transmitter for use with Johnson Metasys networks BN Transmitter for use with BACnet and Modbus networks ENCLOSURE 00 Transmitter only 02 Transmitter with metal enclosure 03 Transmitter with plastic enclosure 04 Transmitter with DIN rail mounting clips 340 March 2014 _ – _ 02 Example: 340 Series BTU meter with standard pulse output and metal enclosure 200 Series A301-20 ST-U24B-XP ST-U24S-XP RELATED PRODUCTS Data Industrial impeller type flow sensors with pulse output Flow/BTU transmitter programming kit, includes cable Temperature sensors, matched ±0.1°F, brass wells Temperature sensors, matched ±0.1°F, stainless steel wells 691-K0A DCP-1.5-W ACCESSORIESPAGE Control transformer, 120:24 VAC, 40 VA, Class 2 979 Power supply, 24 VAC IN to 24 VDC OUT 995 WE MAKE IT EASY. PAGE 290 kele.com 888-397-5353 USA 313 FLOW BTU METER 380 SERIES DESCRIPTION The Badger Meter 380 Series BTU meters provide an inexpensive solution to monitoring thermal energy consumption in cold or hot water systems. The integrated flow and temperature sensors along with the internal metering components make installation and commissioning easy. With on-board Modbus and BACnet communication and a compact design that will fit in a wall, the 380 Series is perfect for networking and multi-tenant billing applications. NEW! FEATURES FLOW 6 • AC or DC power • Field programmable • Scaled pulse or RS-485 (Modbus and BACnet) output standard • Two temperature sensors included • Compact, fits within a standard 2X4 stud wall • Compatible with potable water and water/glycol mixtures WIRING APPLICATION • • • • • 380CS07 Strip Malls Multi-tenant buildings Office buildings Thermal storage systems Sustainable design buildings 2 POWER 1 3 GND 2 - 1 + 2 1 RS 485 PULSE OUTPUT SPECIFICATIONS Supply Voltage Supply VA Supply Current Sensor Input Output Wiring Wiring Terminations Communication Repeatability Size Connections Velocity Range Accuracy 314 12-28 VAC or 12-35 VDC 5 VA 200 mA maximum 0.24" diameter RTD probe, meets IEC751 Class B; 6.5' (2 m) cable for remote sensor, custom fitting for 1/8" NPT pipe tap included Scaled pulse: 10, 50, 150, 200 or 250 ms Two cable glands, PG6 and PG9 Screw terminals inside enclosure Modbus RTU, BACnet ±0.5% 3/4", 1", 1-1/4", 1-1/2", 2" FNPT 1 to 15 fps ± 2% of range 888-397-5353 USA kele.com Operating Temperature-4° to 149°F (-20° to 65°C) Media Temperature Range Cold service -4° to 140°F (-20° to 60°F) Hot service 39° to 257°F (4° to 125°C) Materials Of Construction Cast bronze tee, 316 SS impeller, PEEK flow sensor, polyurethane potting material, polycarbonate housing Enclosure Rating NEMA 4 Weight 3/4" 6 lb (2.7 kg) 1" 7 lb (3.2 kg) 1-1/4" 8 lb (3.6 kg) 1-1/2" 9 lb (4.1 kg) 2" 13 lb (5.9.kg) Warranty 1 year WHEN YOU NEED IT RIGHT, RIGHT NOW, CALL KELE. March 2014 NEW! FLOW BTU METER 380 SERIES DIMENSIONS TOP VIEW Ø8" (20.3 cm) 360° Pivot area case from center of tee Custom RTD fitting 1/8" NPT B Overall height PG-7 PG-9 D Hex 6 C Tee length A Overall length E Width T2 length 6.5 ft. (2 m) Dimensions in (cm) TEE/NPT SIZE 2" Ø0.24" (0.6 cm) A 7.9 (20.1) 7.3 (18.5) 7.1 (18) 6.7 (17.1) 6.7 (17.1) 1.5" 1.25" 1" 3/4" B 8.5 (21.6) 8.3 (21.1) 8.1 (20.6) 7.9 (20.1) 7.9 (20.1) C 7.8) (19.8) 6.7 (17.1) 6.3 (16) 5.4 (13.7) 5.4 (13.7) D 3.3 (8.4) 3.8 (9.7) 2.4 (6.1) 2 (5.1) 2 (5.1) E 3.5 (8.9) 3.5 (8.9) 3.5 (8.9) 3.5 (8.9) 3.5 (8.9) FLOW INSTALLATION 24 AWG twisted, shielded pair Series 380 Btu meter Modbus or BACnet device Series 380 Btu meter Series 380 Btu meter Series 380 Btu meter (Up to 32 units) Model 3700 Data Acquisition Server (Modbus) or similar Modbus or BACnet device ORDERING INFORMATION March 2014 MODEL 380CS07 380CS10 380CS12 380CS15 380CS20 380HS07 380HS10 380HS12 380HS15 380HS20 DESCRIPTION 380 BTU System, cold service, 3/4" FNPT 380 BTU System, cold service, 1" FNPT 380 BTU System, cold service, 1-1/4" FNPT 380 BTU System, cold service, 1-1/2" FNPT 380 BTU System, cold service, 2" FNPT 380 BTU System, hot service, 3/4" FNPT 380 BTU System, hot service, 1" FNPT 380 BTU System, hot service, 1-1/4" FNPT 380 BTU System, hot service, 1-1/2" FNPT 380 BTU System, hot service, 2" FNPT 3700 A304-1M RELATED PRODUCTS Data acquisition server Model 380 programming software WE MAKE IT EASY. kele.com 888-397-5353 USA 315 FLOW NEW! ULTRASONIC ENERGY METER, FLOW METER DE/DB SERIES DESCRIPTION The DE Series ultrasonic energy meter and DB Series ultrasonic flow meter attach externally to water distribution piping to measure flow rate and (the DE Series) supply/return temperature difference to calculate energy consumption. Since they are non-invasive, they add no pressure head loss to the system and can be installed on existing piping systems without shutdown or interruption. Installation is easy and fast, there are no moving parts, and they measure bi-directional flow. The DE energy meter measures energy usage in BTU, MBTU, MMBTU, Tons, kJ, kW, MW and is perfect for retrofit of existing hot water or chilled water hydronic systems. Network communication models include Modbus RTU over RS485, Modbus TCP/IP, and Ethernet communication includes BACNet®/IP, EtherNet/ IP® protocols. 6 The DE and DB meters have a backlit display (available with or without a keypad interface), a USB port for programming, and integral or remote clamp-on flow transducer configurations. The DE Series uses strap-on RTD temperature sensors (immersion sensors are also available). The DE and DB meters work with pipe sizes 1/2" to 100", are available in 24 VAC, 120 VAC, or 24 VDC power, and have a 4-20 mA analog output for flow rate and a pulse output for totalizing. Free ULTRALINK™ software is used to configure the meters. APPLICATION FLOW • • • • Heating/chilled/condenser water Potable water Irrigation water Rain/reclaimed water FEATURES • Backlit display for easy reading in low light • USB Port for configuration and monitoring • No fluid contact means no fluid compatibility issues, no pressure drop, and no plant shutdown necessary for installation • Bi-directional flow measurement for reversing flow systems • Selectable engineering units for international preferences • No moving parts to maintain or replace minimizes service costs • Works with small amounts of suspended solids or aeration • Totalizer options include forward, reverse and net total for flow measurement flexibility • Network communication models available for large projects (up to 126 meters per network) • Keypad models allow access to many parameters • Free Ultralink™ software for configuration SPECIFICATIONS Supply Voltage 95-264 VAC, 47-63 Hz 20-28 VAC, 47-63 Hz 10-28 VDC Frequency DTTS small transducers: 2 MHz DTTN remote transducers: 1 MHz DTTL large pipe transducers 500 kHz Supply VA 17 VA maximum @ 95-264 VAC Supply Watts 5W @ 10-28 VDC Supply Current 0.35 A @ 20-28 VAC Maximum Output ImpedanceAC powered: 400 Ω maximum DC powered: Maximum loop resistance = (Vsupply-7)/0.02 Outputs DE: 4-20 mA internal power, can span negative-to-positive flow/energy rates DB: 4-20 mA internal power, can span negative-to-positive flow/energy rates; two 0-1,000 Hz open collector transistors that can be configured for flow rate, alarming or totalizing Wiring Transducer cables: RG59 coaxial 75 Ω or Twinaxial 78 Ω, (optional armored conduit), maximum length 990' (300 m) in 10' (3m) increments RTDs (DE meters only): Platinum 385, 1 kΩ, 3-wire PVC jacket cable Conduit Opening Two 1/2" FNPT and one 3/4" FNPT Cable Length Remote transducer models available with 20' (6.1m), 50' (15m), or 100' (30m) cables Communication USB: 2.0 for connection to PC running ULTRALINK™ configuration utility RS485: Modbus RTU command set, ENERGYLINK network monitoring software 10/100 Base-T: RJ45 communication via Modbus TCP/IP, Ethernet/IP and BACnet®/IP Configuration PC running free ULTRALINK™ software or via integral display keypad (limited access to parameters) 316 888-397-5353 USA kele.com Accuracy Repeatability Sensitivity Display Engineering Units Pipe Size Range Velocity Range Operating Temperature Media Compatibility Materials Of Construction Enclosure Rating Approvals Warranty Flow: ± 1.0% of reading above 1 fps (0.3 mps) velocity, ± 0.01% of reading below 1 fps (0.3 mps) Temperature (DE only): 0.45°F (0.25°C) 0.5% of reading Flow: 0.001 fps (.0003 mps) Temperature: 0.05°F (.025°C) Two-line LCD, LED backlit, top row: 0.7" (1.8 cm) height, 7-segment; bottom row: .35" (0.9 cm) height, 14-segment; flow rate and totalization indication DB: flow rate in gallons, cubic feet, million gallons, barrels, acre-feet, lbs., meters, cubic meters, liters, million liters, kg. DE: flow rates above plus BTU, MBTU, MMBTU, Tons, kJ, kW, MW 1/2" to 100" (1.2 to 254 cm) 0.1 to 40 fps (feet/second), 0.03 to 12.4 mps (meters/second), bi-directional -40° to 185°F (-40° to 85°C); remote DTTS/ DTTN transducers have upper limit of 250°F (121°C) and high temperature DTTH have upper limit of 400°F (200°C) Most clean liquids or liquids with some suspended solids or aeration Enclosure: powder-coated aluminum, polycarbonate, stainless steel, polyurethane, nickel-plated steel mounting brackets Transducers: NEMA 6 (IP67), PVC/CPVC, Ultem®, Nylon cord grip, PVC cable jacket NEMA 4 (IP65) as long as a liquid-tight connectors are used CSA C22.2 No. 61010-1 (24 VDC, 120 VAC only); CE EN61326-1:2006 1 year WHEN YOU NEED IT RIGHT, RIGHT NOW, CALL KELE. March 2014 NEW! FLOW ULTRASONIC ENERGY METER, FLOW METER DE/DB SERIES INSTALLATION (DE MODEL SHOWN; DB DOES NOT HAVE TEMPERATURE TRANSDUCERS) Bottom Botto om View Integral Flow Transducer Remote Flow Transducers Front View Supply Supply Temperature Transducers Temperature Transducers Return Return Transmitter with remote transducers Transmitter with integral transducers 6 DIMENSIONS AND FLOW RANGES Mechanical Dimensions: Inches (MM) Remote System DTTS/DTTN Transducer Dimensions: Inches (MM) Pipe Size 4.20 (106.7) Pipe Material ANSI/DN 6.00 (152.4) ½" ANSI/DN 4.32 (110) ¾" Pipe mount Wall mount ANSI/DN 2.12 (53.8) 1" 1.38 (35.1) 6.50 (165.1) 2.90 (73.7) 2.30 (58.4) ANSI/DN 1-¼" 1.20 (30.5) .19 DIA (4.8) 2 Mounting holes ANSI/DN 1-½" Integral System 2.12 (53.8) ANSI/DN 2" B D C C (Min Clearance) B A * Varies due to U-bolt configuration A DTTN/DTTH Pipes larger than 2" (50 mm) A DTTN 2.95 (74.9) DTTH 2.95 (74.9) DTTS Pipes/Tubing ½" to 2" (12 mm to 50 mm) B 2.75 (69.8) 2.75 (69.8) C 3.00 (76.2) 3.00 (76.2) DTTL 3.40 2.94 3.20 (86.4) (74.7) (81.3) B D A March 2014 FLOW Measuring Range 2 - 38 GPM 8 - 144 LPM 1.8 - 27 GPM 7 - 102 LPM 1.5 - 18 GPM 6 - 68 LPM 2.75 - 66 GPM 10 - 250 LPM 2.5 - 54 GPM 10 - 204 LPM 2.5 - 45 GPM 10 - 170 LPM 3.5 - 108 GPM 13 - 409 LPM 3.5 - 95 GPM 13 - 360 LPM 3.5 - 85 GPM 13 - 320 LPM 5 - 186 GPM 19 - 704 LPM 4.5 - 152 GPM 17 - 575 LPM 4 - 136 GPM 15 - 514 LPM 6 - 250 GPM 23 - 946 LPM 5 - 215 GPM 19 - 814 LPM 5 - 200 GPM 19 - 757 LPM 2.375 8 - 420 GPM (60.3)* 30 - 1590 LPM 2.125 8 - 375 GPM (54.0)* 30 - 1419 LPM 8 - 365 GPM 30 - 1381 LPM DTTS U-Bolt Connections ANSI/DN & Copper 2" (50 mm) Models B D C WE MAKE IT EASY. A kele.com C 888-397-5353 USA 317 NEW! FLOW ULTRASONIC ENERGY METER, FLOW METER DE/DB SERIES IN: 18-36VAC OUT: 15VDC ASD06-24S15 POWER WIRING FOR 120 VAC ACN OUT− OUT+ -IN+ POWER WIRING FOR 24 VAC R Chassis Gnd. 24 VAC AC Neutral Signal Gnd. Control 1 Control 2 Frequency Out 4-20 mA Out Reset Total Modbus Gnd Modbus B Modbus A O1 N 2 3 4 -Vo R2807 95 - 264 VAC AC Neutral Signal Gnd. Control 1 Control 2 Frequency Out 4-20 mA Out Reset Total Modbus Gnd Modbus B Modbus A Modbus TFX Rx TFX Tx O1 N Modbus TFX Rx TFX Tx + Downstream Upstream + Test P1 +Vo ACL + Downstream Upstream + 6 strodyne www.astrodyne.com PWC-15E 0.15A AC IN : 100-240VAC,50/60Hz DC OUT : +15V / 0.3A 2 3 4 24 VAC Transformer POWER WIRING FOR 24 VDC 4-20 mA Out Reset Total Modbus Gnd TD(A)TD(B)+ GND GND +12V Modbus B Modbus A 10 - 28 VDC Power Gnd. Signal Gnd. Control 1 Control 2 Frequency Out 4-20 mA Out Reset Total Modbus Gnd Modbus B Modbus A RS-485 Model 485SD9TB To 12 VDC Supply RS-232 O1 N TEMPERATURE SENSOR WIRING 2 3 4 Modbus TFX Rx TFX Tx 10 -28 VDC + Downstream Upstream + RS-485 Converter FLOW COMMUNICATIONS WIRING (model specific) Power Ground 4-20 mA OUTPUT WIRING WHITE RED PIN #8 PIN #6 PIN #5 RTD2 BLACK GREEN PIN #4 PIN #3 PIN #2 PIN #1 BROWN RTD1 BLUE DRAIN WHITE BLACK RED DRAIN GREEN BLUE BROWN 318 888-397-5353 USA kele.com PIN#5 PIN#3 PIN#1 PIN#8 PIN#6 PIN#4 PIN#2 *Loop Resistance 1 Signal Gnd. 2 Control 1 3 Control 2 4 Frequency Out 5 4-20 mA Out 6 Reset Total DE/DB Series *Loop resistance maximum = 400 ohms for AC powered units or (supply voltage – 7 VDC/0.02 for DC powered units. WHEN YOU NEED IT RIGHT, RIGHT NOW, CALL KELE. March 2014 NEW! FLOW ULTRASONIC ENERGY METER, FLOW METER DE/DB SERIES ORDERING INFORMATION MODEL DE DB DESCRIPTION BTU Meter Flowmeter PIPE SIZE IA 1/2" ANSI pipe IB 3/4" ANSI pipe IC 1" ANSI pipe ID 1 1/4" ANSI pipe IE 1 1/2" ANSI pipe IF 2" ANSI pipe IG 1/2" copper IH 3/4" copper II 1" copper IJ 1 1/4" copper IK 1 1/2" copper IL 2" copper IM 1/2" OD tubing IN 3/4" OD tubing IP 1" OD tubing IQ 1 1/4" OD tubing IR 1 1/2" OD tubing IS 2" OD tubing RZ Remote Flow Transducers (see DT, DS tables) 6 TRANSDUCER MATERIAL/TEMPERATURE L PVC: -40 to +185˚F (-40 to +185˚C) H CPVC: -40 to +250˚F (-40 to +121˚C) N None (select for Remote Transducer Only) POWER 90-264 VAC A C 20-28 VAC D 11-28 VDC KEYPAD Keypad Y N No keypad COMMUNICATIONS Y N 10/100 Base-T (EtherNet/IP, BACnet/IP, Modbus TCP/IP) No communications ENERGY TEMPERATURE RANGE (Separately ordered RTD kit required) +32 to +122˚F (0 to +122˚C) +32 to +212˚F (0 to +100˚C) N None (for DB flowmeter) H -40 to +350˚F (-40 to +177˚C) X -4 to +85˚F (-20 to +30˚C) FLOW L M APPROVALS N General safety (power supply C only) OPTIONS 0 None, plugged ports 1 Cable Gland Kit Remote transducers for small pipes (with “RZ” pipe size) MODEL DESCRIPTION DTTS Remote transducers for 1/2" to 2" pipes DTTC High Temperature transducer for 1/2” to 2” pipes PIPE SIZE D 1/2" F 3/4" G 1" H 1 1/4" J 1 1/2" L 2" PIPE TYPE P ANSI carbon steel C Copper T Tubing CABLE LENGTH 020 20 feet (6.1 m) 050 50 feet (15 m) 100 100 feet (30 m) CABLE ARMOR OPTION N No armor A Flexible armor CABLE ARMOR LENGTH 000 No armor 020 20 feet (6.1 m) 050 50 feet (15 m) 100 100 feet (30 m) D002-2007-005 D005-0350-300 D005-0803-104 D005-2117-003 D005-2117-004 D010-2102-010 D010-2102-016 D010-3000-120 D010-3000-121 D010-3000-122 March 2014 Remote MODEL DTTN DTTH DTTL transducers for large pipes (with “RZ” pipe size) DESCRIPTION Standard transducer for 2 1/2" to 20" pipes High temperature transducer for 2 1/2" to 100" pipes Large transducer for 22" to 100" pipes CABLE LENGTH 020 20 feet (6.1 m) 050 50 feet (15 m) 100 100 feet (30 m) CABLE ARMOR OPTION N No armor A Flexible armor CABLE ARMOR LENGTH 000 No armor 020 20 feet (6.1 m) 050 50 feet (15 m) 100 100 feet (30 m) OPTIONS N Normal area rating Note: Shaded selections are special order. Note: DT remote transducers come with 36" straps that fit pipes up to 10". (P/N D002-2007-001) ACCESSORIES 72" stainless steel straps, 1 pair, for DTTN/DTTH, for pipes up to 20" RTD Connector Kit (required for non-standard sensors) UltraLink PC software for DE/DB Meters USB A/B Cable, 10 ft. (3 m) for DE/DB Series Meters USB A/B Cable, 15 ft. (4.6 m) for DE/DB Series Meters Mounting track assembly for DTTN/DTTH transducers, for <10" pipes Mounting track assembly for DTTN/DTTH transducers, for 10" to 16" pipes RTD kit for DE Energy Meter, strap-on, 20 ft. cables RTD kit for DE Energy Meter, strap-on, 50 ft. cables RTD kit for DE Energy Meter, strap-on, 100 ft. cables WE MAKE IT EASY. kele.com 888-397-5353 USA 319 FLOW PADDLE FLOW SWITCH 626600A DESCRIPTION The 626600A Flow Switch from Caleffi is used to prove liquid flow in 1" to 8" pipes containing water, 50% or less glycol solutions, or other liquids that are compatible with stainless steel, brass, and EPDM. It is designed for use in HVAC systems, heat exchangers, pumping systems, water treatment, and process systems in general. The high quality of Model 626600A makes it ideal for controlling pumps, burners, compressors, refrigerators, motorized valves, or for activation of signaling units or warning devices. NEW! 6 FEATURES • 316L stainless steel bellows for durability and long life • NEMA 5 (IP54) environmental rating for use in humid or dusty environments • Six stainless steel blades to fit 1" to 8" pipes • Insulated cover over microswitch contacts for safety • Large, easily-accessible calibration screw with locking nut to maintain setpoint FLOW 626600A WIRING SPECIFICATIONS Contact Rating Resistive/Inductive: 15A @ 240 VAC maximum; Lamp load: 3A @ 125 VAC for the N.C. contact, 1.5A @ 125 VAC for the N.O. contact; Motor load: 5A, 1/4 HP @ 125 VAC for the N.C. contact, 2.5A, 1/8 HP @ 125 VAC for the N.O. contact Pipe Size Range 1" to 8" (2.5 to 20 cm) Connections 1" MNPT Operating Temperature130°F (55°C) maximum ambient Media Temperature Range -22° to 250°F (-30° to 121°C) Maximum System Pressure 150 psig (1 bar) Materials Of Construction Wetted parts: P-Cu Zn40 Pb2 brass body, 316L stainless steel bellows, EPDM o-ring; Housing cover: Class UL94V-0 self-extinguishing polycarbonate Approvals CE, UL File E307420 Weight 1.7 lb (0.8 kg) Warranty 2 years 320 888-397-5353 USA kele.com 1 COMMON 3 NO 2 NC Shown in no-flow, normal position WHEN YOU NEED IT RIGHT, RIGHT NOW, CALL KELE. March 2014 NEW! FLOW PADDLE FLOW SWITCH 626600A DIMENSIONS 1/2" FNPT conduit connection 3"-DN 80 $ 1" 1.25" 1.5" 2" 2.5" 3.4 (87) in (mm) 5.5 (135) 3.1 (80) 4"-DN100 5"-DN125 6"-DN150 DN 175 8"-DN200 6 Select the blade marked with the diameter of the pipe in which the switch will be installed. For pipe sizes 1" to 2.5", remove all extra pre-fitted blades. For pipes 3" and above, leave all pre-fitted blades installed and add the long blade and trimming as shown for pipe size. Install the switch in the pipe, observing the flow direction arrows shown on the body casting and housing cover. The distance between the top of the pipe and the upper surface of the brass housing should be 3.1" (80 mm). The switch can be installed in a horizontal or vertical pipe, but avoid installing the switch below horizontal; dirt and deposits may collect in the switching mechanism and affect operation. OPERATION 1" 1.25" 1.5" 2" 2.5" 3" 4" 5" 6" 8" Minimum calibration Operating flow rate with increasing flow 5.7 (21.7) 7.5 (28.4) 11.4 (43.4) 13.2 (50.1) 22.0 (83.5) 29.9 (113) 44.0 (167) 61.1 (232) 72.6 (275) 162 (618) Minimum calibration Operating flow rate with decreasing flow 4.0 (15.0) 5.5 (20.9) 8.4 (31.7) 9.7 (36.7) 16.3 22.9 (61.8) (86, 8) 37.4 (142) 51.5 (197) 63.8 (242) 145 (551) Maximum calibration Operating flow rate with increasing flow 12.3 (46.8) 16.7 (63.5) 26.0 (98.5) 29.5 (112) 51.5 (195) 69.5 (264) 94.6 (359) 136 (518) 189 334 (718) (1269) Maximum calibration Operating flow rate with decreasing flow 11.9 (45.1) 16.3 (61.8) 25.5 (96.9) 29.0 (110) 50.6 (192) 68.6 (260) 92.4 (351) 127 (484) 158 308 (601) (1169) Diameter of Pipe FLOW Operating flow rates: gpm (lpm) CALIBRATION B A C If the required operating flow rate differs from that given in the table below, the necessary correction should be carried out as follows: turn the calibration screw (A) in a clockwise direction for the contacts to close at higher flow rate values or in a counterclockwise direction for lower flow rate values. When the adjustment has been made, lock the screw (A) with the locking ring nut (B). Avoid all contact with the presetting screw (C). An incorrect setting would seriously impair the operation of the switch. ORDERING INFORMATION MODEL 626600A March 2014 DESCRIPTION Paddle flow switch, 1" to 8" pipes, NEMA 5 WE MAKE IT EASY. kele.com 888-397-5353 USA 321 FLOW FLOW SWITCH FS1-6 DESCRIPTION The Kele FS1-6 paddle flow switch is designed to prove liquid flow in a wide variety of HVAC and industrial applications. The corrosion-resistant flow switch is mounted in a weather-resistant box for simple wiring connections. The polyphenylene sulfide plastic vane is field trimmable for 1" (2.54 cm) and larger pipes, and it is magnetically coupled to the SPDT switch to prevent liquid from entering the switch housing. NEW! FEATURES FLOW 6 • • • • • Weather-resistant construction Simple installation Leak-proof magnetic switch operation Field adjustable for 1" (2.54 cm) and larger pipes SPDT snap-acting switch DIMENSIONS SPECIFICATIONS Contact Arrangement SPDT; black wire = common, red wire = normally open (at no flow), blue wire = normally closed (at no flow) Contact Rating 5A @ 125/250 VAC Wiring 18" (46 cm) leads, 18 AWG Pipe Size Range 1" to 12" (2.5 to 30 cm) Connections 1" MNPT Media Temperature Range 212°F (100°C) maximum Maximum System Pressure 150 psig (1 bar) Materials Of Construction Wetted parts: Polyphenylene sulfide vane, ceramic 8 magnet, 316 stainless steel spring and pin Weight 1 lb (.45 kg) Warranty 1 year in (cm) 2.75 (6.99) 2.25 (5.72) 4.50 (11.43) 13.25* (33.66) 1" NPT pipe connection 5.00* (12.70) 1.00 (2.54) WIRING Black - Common Red - Normally open (no flow) Blue - Normally closed (no flow) 322 888-397-5353 USA kele.com * Dimension with vane full length for 6" and larger pipe installation WHEN YOU NEED IT RIGHT, RIGHT NOW, CALL KELE. March 2014 NEW! FLOW FLOW SWITCH FS1-6 INSTALLATION 1. Carefully unpack switch, making sure to remove any packing from the lower housing. Adjust the actuation or deactuation point by trimming the vane to the length desired. If using a pipe with weld-o-let, cond-o-let, or plastic PVC fittings, use graduations indicated on the vane. If using standard 125 or 250 lb (57 or 113 kg) bronze, iron, or steel fittings, trim the vane 0.125" (0.32 cm) above the marking provided. Because of the great variation in fittings and process connections, it is recommended the unit be checked when installed to ensure proper operation and that there is no interference between the vane and the fittings. For pipes larger than 6" (15.24 cm), leave the vane full length. 2. This flow switch is intended to be used in clean process media where particles, scale, and debris are not present. Buildup of such materials may cause inaccurate signals. 3. The switch must be indexed during installation in the line with the flow arrow on the side of the switch pointing in the direction of the flow. Pipe sealant is required at the 1" NPT thread connection. It is important to not get the sealant in the vane assembly as it may prevent proper operation and cause misleading signals. When installing the unit, be certain not to over-torque the housing. Damage may occur if excessive force is used. 6 4. Connect the switch wires in accordance with local electrical codes. The FS1-6 is not intended to be a load-carrying conduit connection. Loads may damage the switch and stop operation. PIPE SIZE 1 1.25 1.5 2 3 4 6 8 10 12 ACTUATION gpm (lpm) 10.7 (40.5) 9.5 (36.0) 8.1 (30.7) 9.8 (37.1) 12.4 (46.9) 20.2 (76.5) 43.0 (163) 74.2 (281) 116.7 (442) 167.1 (632) FLOW PERFORMANCE DEACTUATION gpm (lpm) 9.3 7.7 6.3 8.5 8.9 12.7 32.8 56.6 89.0 127.4 (35.2) (29.1) (23.9) (32.2) (33.7) (48.1) (124) (214) (337) (482) ORDERING INFORMATION MODEL FS1-6 March 2014 DESCRIPTION Weather-resistant flow switch WE MAKE IT EASY. kele.com 888-397-5353 USA 323 FLOW FLOW SWITCH F61 SERIES DESCRIPTION 6 The Johnson Controls F61 Series paddle flow switches are used to prove flow on liquid lines using water, ethylene glycol solutions, or other liquids compatible with brass and phosphor bronze parts. The SPDT contact switch is activated by liquid flow through the pipe and the set point is adjustable. The F61KD (NEMA 1 enclosure) and F61MD (NEMA 3R enclosure) are inline models for 1/2" NPT and 3/4" NPT pipe. The F61KB-11 (NEMA 1 enclosure) and F61MB-1 (NEMA 3R enclosure) are for 1" (2.5 cm) and larger pipes. They are furnished with a stainless steel paddle in three segments for pipes 1" to 3" (2.5 to 7.6 cm) in diameter. Paddle segments may be removed or trimmed as needed. A 6" (15 cm) paddle is also furnished for 4" (10 cm) diameter pipes and larger. NEW! F61KB-11 F61KD-3 FLOW SPECIFICATIONS Media Temperature Range KB-11, KD-3, KD-4 32°F to 250°F (0°C to 121°C) MB-1, MD-1, MD-2 -20°F to 250°F (-30°C to 121°C) Maximum System Pressure 150 psig (1034 kPa) Materials Of Construction KB-11, MB-1, KD-3, KD-4 MD-1, MD-2 Approvals Warranty Brass fittings, phosper bronze bellows, stainless steel paddle Brass fittings, stainless steel bellows, stainless steel paddle UL recognized, File E5368 1 year WIRING ELECTRICAL RATINGS MOTOR RATINGS Horsepower AC full load amps AC locked rotor amps 120V 208V 1 1 16 8.8 96 52.8 Noninductive or Resistance load amps 240V 277V 1 – 8 – 48 – 16 16 16 Pilot duty – 125 VA 24/277 VAC 16 Action on increase of flow B Y R F61 Series DIMENSIONS 324 Model Size Connections Dimensions Weight Enclosure Rating F61KD-3 1/2" FNPT inline 5.0"H x 4.0"W x 2.8"D (12.8 x 10.1 x 7.1 cm) 2.1 lb (.95 kg) NEMA 1 F61MD-1 1/2" FNPT inline 5.0"H x 4.0"W x 2.8"D (12.8 x 10.1 x 7.1 cm) 2.2 lb (1.0 kg) NEMA 3R F61KD-4 3/4" FNPT inline 5.0"H x 4.0"W x 2.8"D (12.8 x 10.1 x 7.1 cm) 2.1 lb (.95 kg) NEMA 1 F61MD-2 3/4" FNPT inline 5.0"H x 4.0"W x 2.8"D (12.8 x 10.1 x 7.1 cm) 2.2 lb (1.0 kg) NEMA 3R F61KB-11 1" 1" MNPT insertion 8.4"H (3" paddle) x 4.0"W x 2.8"D (21.3 x 10.2 x 7.1 cm) 1.7 lb (.77 kg) NEMA 1 F61MB-1 1" 1" MNPT insertion 8.7"H (3" paddle) x 4.8"W x 2.8"D (22.1 x 12.2 x 7.1 cm) 2.4 lb (1.1 kg) NEMA 3R 888-397-5353 USA kele.com WHEN YOU NEED IT RIGHT, RIGHT NOW, CALL KELE. March 2014 NEW! FLOW FLOW SWITCH F61 SERIES ADJUSTMENTS: TYPICAL FLOW RATES — gpm (m3/hr) LINE PIPE SIZE (in) Flow increases R to Y closes Flow decreases R to B closes Flow increases R to Y closes Flow decreases R to B closes MODEL F61KB-11 F61MB-1 Minimum adjustment Maximum adjustment 1 1-1/4 1-1/2 2 2-1/2 3 4.2 (1.0) 5.8 (1.3) 7.5 (1.7) 13.7 (3.1) 18.0 (4.1) 27.5 (6.2) 2.50 (0.6) 3.70 (0.8) 5.00 (1.1) 9.50 (2.2) 12.50 (2.8) 19.00 (4.3) 8.80 (2.0) 13.30 (3.0) 19.20 (4.4) 29.00 (6.6) 34.50 (7.8) 53.00 (12.0) 8.50 (1.9) 12.50 (2.8) 18.00 (4.1) 27.00 (6.1) 32.00 (7.3) 50.00 (11.4) 4* 5* 6* 8* 65.0 (14.8) 37.0† (8.4) 50.0 (11.4) 27.0† (6.1) 128.0 (29.1) 81.0† (13.4) 122.0 (27.7) 76.0† (17.3) 125.0 (28.4) 57.0† (12.9) 101.0 (22.9) 41.0† (9.3) 245.0 (55.6) 118.0† (26.8) 235.0 (53.4) 111.0† (25.2) 190.0 (43.1) 74.0† (16.8) 158.0 (35.9) 54.0† (12.3) 375.0 (85.2) 144.0† (32.7) 360.0 (81.8) 135.0† (30.7) 375.0 (85.2) 205.0† (46.6) 320.0 (72.7) 170.0† (38.6) 760.0 (172.6) 415.0† (94.2) 730.0 (165.8) 400.0† (90.8) MODEL INLET/OUTLET SIZE (Female NPT) NEMA Enclosure 1/2" x 1/2" 3/4" x 3/4" 1/2" x 1/2" 3/4" x 3/4" 1 1 3R 3R F61KD-3 F61KD-4 F61MD-1 F61MD-2 FLOW *Flow rates for these sizes are calculated. † These gpm figures are for switch with 6" paddle. For 4" and 5" line pipe the paddle is trimmed. 6 ADJUSTMENT RANGE – gpm (m3/hr) R to Y closes flow increase R to Y opens flow decrease Minimum 0.6 (0.14) Maximum 1.1 (0.25) Minimum 0.3 (0.07) Maximum 0.9 (0.2) ORDERING INFORMATION MODEL F61KD-3 F61MD-1 F61KD-4 F61MD-2 F61KB-11 F61MB-1 March 2014 DESCRIPTION Flow switch inline 1/2" x 1/2" NPT, NEMA 1 Flow switch inline 1/2" x 1/2" NPT, NEMA 3R Flow switch inline 3/4" x 3/4" NPT, NEMA 1 Flow switch inline 3/4" x 3/4" NPT, NEMA 3R Flow switch for pipe 1" diameter and larger, NEMA 1 Flow switch for pipe 1" diameter and larger, NEMA 3R WE MAKE IT EASY. kele.com 888-397-5353 USA 325 FLOW COU, LIM, JAG, AND PAN MODELS EDC CONDENSATE PUMPS DESCRIPTION Kele offers a variety of condensate removal pumps that are small, quiet running, and high performance for air conditioning and ventilation systems. Rigorously tested for total efficiency over a long life-span, these devices are in use all over the world. FEATURES DRAIN PAN PUMP (COU) • Electronic Energy Control System (EECS) for quiet start/stop • Designed for low-cost installations • Compact dimensions • Completely encapsulated electronics • Auto-sensing power, one model for 110/120 or 208/240 VAC 6 LIMPET CONDENSATE DISCHARGE (LIM) • Electronic Energy Control System (EECS) for quiet start/stop • 120V or 240V auto sensing • Built-in alarm circuit • Thermal protection • Built-in non-return valves CONDENSATE PUMP (JAG) • Electronic Energy Control System (EECS) for quiet start/stop • Electronic control with high water alarm • Fits all wall-mount air conditioners • Mounts vertically or horizontally NEW! COU LIM JAG PAN CONDENSATE REMOVAL (PAN) • Electronic Energy Control System (EECS) for quiet start/stop • Small footprint, low profile for ease of mounting • Electronic control with high water alarm • Tiny remote mount reservoir/sensing unit • Fits all wall-mount splits FLOW COMMON SPECIFICATIONS Supply Voltage 120-240 VAC 50/60 Hz auto sensing Supply Watts 17W Operating Temperature 32° to 104°F (0° to 40°C) Media Temperature Range104°F (40°C) maximum Alarm Relay 5A, 30 VDC, 250 VAC breaks on fault Maximum Capacity 3.2 gallons/hour (12 liters/hour) Maximum Discharge Lift Approvals Warranty 65' (20 m) CE, UL94 5 VA flame retardant ABS material 2 years DIMENSIONS Model Dimensions Wiring COU.6000.0 1.7"H x 1.3"W x 6.3"L (4.3 x 3.43 x 16.0 cm) with .25" (.6 cm) ID discharge tube 18" (46 cm) 5-conductor cable, alarm contacts rated 5A @ 250 VAC, 30 VDC, break on fault LIM.6000.0 2.4"H x 2.0"W x 11.3"L (6.1 x 5.3 x 28.6 cm) with .25" (.6 cm) ID discharge tube 18" (46 cm) 5-conductor cable, alarm contacts rated 5A @ 250 VAC, 30 VDC, break on fault JAG.6000.0 1.8"H x 1.6"W x 6.9"L (4.6 x 4.0 x 17.5 cm) with .25" (.6 cm) ID discharge tube 40" (1 m) 18 AWG 5-conductor cable, alarm contact rating 5A @ 250 VAC maximum, break on fault PAN.6000.0 Pump: 1.3"H x 1.8"W x 5.3"L (3.2 x 4.6 x 13.5 cm) with .25" (.6 cm) ID discharge tube Remote Sensor: 1.4" dia. x 1.8"W (3.6 x 4.5 cm) with 5' (1.5m) x 0.125" (3.3 mm) tube 40" (1 m) 18 AWG 5-conductor cable, alarm contact rating 5A @ 250 VAC maximum, break on fault ORDERING INFORMATION 326 MODEL COU.6000.0 LIM.6000.0 JAG.6000.0 PAN.6000.0 DESCRIPTION Drain pan pump, 110-230 VAC auto sensing, 3.2 gph (12 lph) Condensate discharge system, 110-230 VAC auto sensing, 3.2 gph (12 lph) Condensate pump, 110-230V 50/60 Hz auto sensing, 3.2 gph (12 lph) Condensate pump with remote sensor, 110-230V 50/60 Hz auto sensing, 3.2 gph (12 lph) ACC.0038.0 ACC.0056.0 DPP.0076.0 LIM.0071.0 PCF.0061.0 ACCESSORIES Inline filter kit for PAN, JAG pumps Anti-syphon valve kit Drain pan pump skirt filter Replacement filter element for LIM.4000 system Acoustic jacket for JAG, PAN pumps 888-397-5353 USA kele.com WHEN YOU NEED IT RIGHT, RIGHT NOW, CALL KELE. March 2014 NEW! FLOW PORTABLE ULTRASONIC FLOW AND ENERGY METER DXN SERIES DESCRIPTION The Badger Meter DXN Series portable ultrasonic flow and energy meter is a true hybrid instrument, capable of measuring liquid flow with multiple technologies, including: Doppler, transit time and liquid thermal (heat energy) flow. Easy to install by clamping onto the outside of the pipe, the DXN measures flow using non-invasive ultrasonic sensors. Compatible with a pipe wall thickness gauge, inside pipe diameter can be verified to ensure accurate ultrasonic measurements when piping details are unknown or unavailable. The DXN Series has a number of advanced features including a touchscreen interface, full-color graphing, wizard-based start-up configuration, USB connectivity, and Modbus TCP/IP connectivity. These features make it easy for technicians to obtain accurate readings while capturing flow surges and high-speed batch operations. The DXN Series captures and displays multiple user-defined and application parameters at once and can record the data with an easy-touse data logging function. The ability to monitor and record several parameters at once allows technicians to verify and troubleshoot permanent flow installations with ease. 6 DXN w Transducers SPECIFICATIONS Input Signal Digital Inputs Cable Length Repeatability Display Pipe Size Range Velocity Range Storage Temperature Approvals Ambient Conditions Battery Breakout Box Connector Digital Output Rate or Total Pulse User Selectable Enclosure Energy or Temperature Flow Rate Accuracy March 2014 80kΩ input impedance 14 V @ 50 mA max for powering current or voltage sensors Totalizer reset, external pull-up Transit time: 20' (6 m) paired coaxial cable, BNC to BNC, Doppler: 20' (6 m) paired coaxial cable, BNC to 4-pin ±0.1% of reading 800 x 480 WVGA Color Outdoor Readable Display; Gloved-operation resistive touch screen 1/2" and larger; US standard pipe tables are built into User interface Transit Time: Bi-directional to 40 FPS (12 MPS) Doppler: Uni-directional to 40 FPS (12 MPS) Do not exceed 175°F (80°C) Safety: UL61010-1, CSA C22.2 No. 61010-1, EN61010-1 Directives: 2006/95/EC Low Voltage, 2004/108/EC EMC Battery powered: -4° to 110°F (-20° to 45°C) Externally powered: -20° to 140°F (-30° to 60°C) Internal 11.1 V lithium ion battery, 75W-hr. Provides 6-9 hrs of continuous operation with battery and indefinitely on external power. Charging 32° to 104°F (0° to 40°C), 12 hours while in use; 4 hours powered off 0.2" quick disconnect screw terminals; 15 pin to adapter box; 6' (1.8 m) of cable (DSUB to DSUB connectors) 15-pin high-density DSUB Open collector, external or pull-up Rate pulse: 0-1000 Hz Total pulse: 33 ms duration Water/Dust resistant [IP 64] 2x RTDs PT1000 tab type; can handle various temperature ranges from -58° to 570°F (-50° to 300°C), based on RTD type Transit Time: ±1% of reading or ±0.01 Flow Sensitivity Housing Material Liquid Types Logging Sampling Rate Measurement Update Output Current Output Voltage FPS (0.003 MPS), whichever is greater Doppler: 2% of full scale 0.001 FPS (0.0003 MPS) DTTSU: CPVC, Ultem®, and anodized aluminum track system; Nickel-plated brass connector with Teflon® insulation DTTN/DTTL/DT94: CPVC, Ultem®; Nickel-plated brass connector with Teflon® insulation Liquid dominant fluids >300 sites stored in 1 GB; downloads to USB Flash drive 0.1-10 seconds update/filter rate. Transit time, up to 50 Hz high speed mode 4-20 mA active/passive 1% accuracy 0-5 V or 0-10 V output voltage, 1% accuracy FLOW Software Scaling and Control Sensor Input Voltage input. 0-5V or 0-10 V, 1% accuracy Software Scaling and Control 100Ω output impedance Pipe Surface Temperature DTTSU/DTTN/DTTL: -40° to 250°F (-40° to 121°C) DT94: -40° to 250°F (-40° to 121°C) Pipe Thickness Dual mode transducer with 6' (1.8 m) of cable (BNC ends) Power Cords North American plug (2 flat & 1 round prong; NEMA 5/15P); China plug (3 flat prongs; GB2099); Euro plug (2 round prongs; CEE7/7); U.K. plug (3 rectangular prongs; BS1363A); Japan plug (2 flat & 1 round, JIS8303, w/ 3-2 prong adapter) Power Requirements 10-30 VDC via-3-pin connector, 40 W min; 3.6A resettable fuse Supplies: Desktop adapter: 100-240 VAC 50/60 Hz 50 W 10V-18V; Cigarette lighter adapter: 5A fused RTDs 2x platinum 385, 1000Ω, 3-wire PVC jacketed cable standard with quick connector Temperature Accuracy Absolute 0.5°F (1°C); Difference 0.2°F (0.5°C); Resolution 0.02°F (0.01°C) Transducer Frequency DTTSU: 2 MHz, DTTN: 1 MHz, DTTL: 500 kHz DT94: 625 kHz User Menu Windows .NET fully integrated user menu; multi-language: English, Spanish, German, French, Portuguese, Japanese, Russian, Italian, Dutch, Norwegian, and Swedish Approvals CSA Warranty 1 year WE MAKE IT EASY. kele.com 888-397-5353 USA 327 FLOW NEW! PORTABLE ULTRASONIC FLOW AND ENERGY METER DXN SERIES SENSOR AND HARDWARE KIT OPTIONS Basic All Transit Time Basic Kit and large pipe transducers Hybrid Basic kit and Doppler transducers Energy Basic kit and non-invasive RTDs (1) Silicone Heat Sink Compound; 5 oz syringe (1) RTD Installation tape, 36 ft Full Basic kit plus all, transit time, Doppler, RTDs and pipe wall thickness gauge (1) Silicone Heat Sink Compound; 5 oz syringe (1) RTD Installation tape, 36 ft (2) Stainless steel straps (1/2" wide, 21-1/4" max dia., worm drive clamp) PARTS AND ACCESSORIES Power Cords/Cables FLOW 6 Small pipe and standard pipe transit time transducers (1) Couplant, grease; 5.3 oz; Dow 111 (1) Couplant, Ultrasound gel; 0.25 liter bottle (4) Stainless steel straps (1/2" wide, 12-5/16" max dia., worm drive clamp) Part Number Description D005-2109-013 North American plug (2 flat & 1 round prong; NEMA 5/15P) D005-2109-015 UK plug (3 rectangular prongs; BS1363A) D005-2109-016 Euro plug (2 round prongs; CEE7/7) D005-2109-017 Japan plug (2 flat & 1 round, JIS8303, w/ 3-2 prong adapter) D005-2109-014 China plug (3 flat prongs; GB2099) D005-2129-020 Transit time Cables, 20' (6 m) D005-2129-050 Transit time Cables, 50' (15 m) D005-2129-100 Transit time Cables, 100' (30 m) D005-2130-020 Doppler Cables, 20' (6 m) D005-2130-050 Doppler Cables, 50' (15 m) D005-2130-100 Doppler Cables, 100' (30 m) Transducers (Heads with case) Part Number Description D010-2200-002-C DTTSU universal small pipe Minimum Pipe O.D. D071-0110-000-C DTTN standard pipe D071-0110-200-C DTTL large pipe D071-0112-001-C DT94 Doppler transducer Maximum Pipe O.D. 0.5" (12 mm) 2.4" (60.3 mm) 2" (50 mm) 98" (2500 mm) 16" (400 mm) 120" (3050 mm) 1" (25 mm) 60" (1524 mm) RTDs/Accessories/Spare Parts 328 Part Number Description D002-2007-004 0… 392º F (200º C) RTD Silicone stretch tape D002-2007-001 36" (914 mm) SS Hose clamp / transducer strap D002-2007-005 72" (1829 mm) SS Hose clamp / transducer strap D002-2011-001 Acoustic couplant, grease (Dow 111), 150° F (65° C) 5.3 oz tube D002-2011-011 D010-3000-128 Acoustic couplant, paste high temperature, 142 gram tube, 392° F (200° C) Industrial RTD Kit,1 1000 Ohm, 392° F (200° C); 20' (6 m) cable D010-3000-129 Building Automation RTD Kit,1 1000 Ohm, 266° F (130° C); 20' (6 m) cable 888-397-5353 USA kele.com WHEN YOU NEED IT RIGHT, RIGHT NOW, CALL KELE. March 2014 NEW! FLOW PORTABLE ULTRASONIC FLOW AND ENERGY METER DXN SERIES DIMENSIONS DTTSU Transit Time Transducer 7.00 (177.8) 1.65 (41.9) 1.54 (39.1) 0.3 1.0 1.5 2.0 9.45 (240) DTTN Transit Time Transducer 6 3.45 (87.6) 3.50 (88.9) 7.78 (197.6) 1.54 (39.1) FLOW 3.77 (95.7) 1.70 (43.2) DTTL Transit Time Transducer 4.21 (106.9) DXN Connection Panel Doppler Transducer Transit Time Transducer (Upstream) Transit Time Transducer (Downstream) Auxiliary I/O 3.90 (99.0) 2.48 (63.0) 2.50 (63.5) Power/Charger USB On/Off Switch Ethernet Transducer Pipe Size Requirements Minimum Pipe O.D. DTTSU .5" (12 mm) Maximum Pipe O.D. 1.70 (43.2) 4.13 (104.9) 1.89 (48.0) 2.4" (60.3 mm) DTTN 2" (50 mm) 98" (2500 mm) DTTL 16" (400 mm) 120" (3050 mm) DT94 1" (25 mm) 60" (1524 mm) March 2014 DT94 Doppler Transducer WE MAKE IT EASY. kele.com 888-397-5353 USA 329 NEW! FLOW PORTABLE ULTRASONIC FLOW AND ENERGY METER DXN SERIES ORDERING INFORMATION MODEL DXNP DESCRIPTION Portable Clamp-on Ultrasonic Flow Meter POWER CORD A North American U U.K., Singapore E Euro J Japan C China SENSOR & HARDWARE KIT B Basic T All transit time H Hybrid E Energy F Full CARRYING CASE S Standard - Outer case with shoulder strap APPROVALS N CE + General Safety, U.S., Canada, and EU OPTIONS N None DXNP A FLOW 6 330 888-397-5353 USA B S kele.com N N Example: DXNP-A-B-S-N-N Portable clamp-on ultrasonic flow meter with North American power cord, basic sensor and hardware kit, standard carrying case, CE + General Safety approvals and no options WHEN YOU NEED IT RIGHT, RIGHT NOW, CALL KELE. March 2014 NEW! FLOW INDUSTRIAL OVAL GEAR METER IOG SERIES DESCRIPTION The Badger Meter Model IOG (industrial oval gear meter), is a modular flow meter design, economical yet highly accurate and rugged. The Model IOG is designed for a variety of chemical applications including petroleum based fluids, water solutions, and any other liquid compatible with the materials of construction. OPERATING PRINCIPLE Fluid enters the inlet port and then passes through the metering chamber. Inside the chamber, fluid forces the internal gears to rotate before exiting through the outlet port. Each rotation of the gears displaces a specific volume of fluid. As the gears rotate, a magnet on each end of the gear passes a reed switch in the top-mounted register’s circuit board. The reed switches send pulses to the microprocessor in the register to change the LED display segments. The oval gear meter can be used in conjunction with a variety of industrial registers. See the online documentation for Oval Gear Meter Registers, ER-420 Flow Rate/Totalizer, and the ER-500 Flow Monitor for more information on the available register options. 6 Industrial Oval Gear APPLICATION • • • • • Due to the rugged nature of this particular flow measurement technology, the Industrial Oval Gear Meter can be used in a number of applications where conventional meters are not acceptable. Whether the liquid being measured is very viscous or highly corrosive, the oval gear meter can handle it. The Industrial Oval Gear Meter is designed for a variety of applications including petroleum based fluids, water solutions, and any other liquid compatible with the materials of construction. • • • • Compact size High accuracy and repeatability Factory calibrated (stated in pulses per liter) Flow range of 0.067-185 gpm Flexibility of installation options (vertical installation or horizontal installation) Low pressure drop Minimum number of wearable parts for long product life and easy field servicing Wide range of instrumentation available for control system interfacing Certifcations: UL File#913, CSA Pressure Rating (psi) Port Size 1/4" 1/2" 3/4" 1" 1" HF 1-1/2" 2" 3" March 2014 Housing Material Stainless Aluminum Stainless Aluminum Stainless Aluminum Stainless Aluminum Stainless Aluminum Stainless Aluminum Stainless Aluminum Stainless Aluminum Rotor Material Operating Temperature Range NPT/BSP ANSI 150# ANSI 300# Stainless Steel -22° to 240°F (-30° to 120°C) 1000 1500 3000 2000 3000 2000 3000 2000 3000 2000 2000 1500 1500 1000 1000 750 - 740 740 740 740 740 740 - LCP -22° to 176°F (-30° to 80°C) 285 285 285 285 285 285 285 FLOW FEATURES SPECIFICATIONS Approvals Warranty WE MAKE IT EASY. CSA 1 year kele.com 888-397-5353 USA 331 NEW! FLOW INDUSTRIAL OVAL GEAR METER IOG SERIES DIMENSIONS FLOW 6 Port Size A B C D E F G H J K L M N 1/4" 2.17" (55 mm) 1.54" (39 mm) 2.05" (52 mm) — — — — — — — — — — 1/2" 3.94" (100 mm) 3.44" (87.5 mm) 3.62" (92 mm) 9.70" 5.12" 8.93" 10.10" 6.69" 8.45" 7.68" 8.89" 3.94" 4.84" (246.4 mm) (130 mm) (226.8 mm) (256.5 mm) (170 mm) (214.6 mm) (195.1 mm) (225.8 mm) (100.2 mm) (122.9 mm) 3/4" 3.94" (100 mm) 3.84" (97.5 mm) 3.62" (92 mm) 10.10" 5.12" 9.33" 10.50" 6.69" 8.70" 7.93" 9.14" 3.94" 4.84" (256.5 mm) (130 mm) (236.9 mm) (266.7 mm) (170 mm) (220.9 mm) (201.4 mm) (232.2 mm) (100.2 mm) (122.9 mm) 1" 3.94" (100 mm) 3.84" (97.5 mm) 3.62" (92 mm) 10.10" 5.12" 9.33" 10.50" 6.69" 8.70" 7.93" 9.14" 3.94" 4.84" (256.5 mm) (130 mm) (236.9 mm) (266.7 mm) (170 mm) (220.9 mm) (201.4 mm) (232.2 mm) (100.2 mm) (122.9 mm) 1" HF 3.94" (100 mm) 3.89" (98.9 mm) 3.62" (92 mm) 10.15" 5.12" 9.38" 10.55" 6.69" 8.60" 7.83" 9.04" 3.94" 4.84" (257.8 mm) (130 mm) (238.3 mm) (268.0 mm) (170 mm) (218.4 mm) (198.8 mm) (229.6 mm) (100.2 mm) (122.9 mm) 1-1/2" 5.51" 4.93" 4.92" 11.15" 5.12" 10.38" 11.51" 8.35" 8.90" 8.13" 9.31" (140 mm) (125.3 mm) (125 mm) (283.2 mm) (130 mm) (263.7 mm) (292.4 mm) (212 mm) (226.1 mm) (206.5 mm) (236.5 mm) — — 2" 5.91" 5.34" 5.28" 11.60" 5.12" 10.83" 11.96" 10.39" 9.16" 8.39" 9.57" (150 mm) (135.6 mm) (134 mm) (294.6 mm) (130 mm) (275.1 mm) (303.8 mm) (264 mm) (232.7 mm) (213.1 mm) (243.1 mm) — — 3" 8.27" 6.35" 7.09" 12.57" 5.12" 11.80" 12.93" 13.54" 9.58" 8.81" 9.99" (210 mm) (161.4 mm) (180 mm) (319.3 mm) (130 mm) (299.7 mm) (328.4 mm) (344 mm) (243.3 mm) (223.8 mm) (253.8 mm) — — 332 888-397-5353 USA kele.com WHEN YOU NEED IT RIGHT, RIGHT NOW, CALL KELE. March 2014 NEW! FLOW INDUSTRIAL OVAL GEAR METER IOG SERIES FLOW RANGE AND MATERIALS OF CONSTRUCTION FLOW RANGE American (gpm) Port Size 1/4" 1/2" 3/4" 1" 1" HF 1-1/2" 3" Low High Low High Fluid Viscosity .067 2.2 0.25 8.3 > 5.0 cP Accuracy (%) ± 1.0 0.11 2.2 0.44 8.3 < 5.0 cP ± 2.5 0.25 8.0 1.0 30 > 5.0 cP ± 0.5 0.50 6.6 2.0 25 < 5.0 cP ± 2.0 0.50 16 2.0 60 > 5.0 cP ± 0.5 1.20 14 4.5 53 < 5.0 cP ± 2.0 0.6 18 2.3 68 > 5.0 cP ± 0.5 1.4 16 5.3 60 < 5.0 cP ± 2.0 1.5 45 5.7 170 > 5.0 cP ± 0.5 2.5 40 9.5 151 < 5.0 cP ± 2.0 2.5 65 9.5 246 > 5.0 cP ± 0.5 4.0 60 15 227 < 5.0 cP ± 1.0 4.0 100 15 379 > 5.0 cP ± 0.5 6.0 100 23 379 < 5.0 cP ± 1.0 5.0 185 19 700 > 5.0 cP ± 0.5 10 185 38 700 < 5.0 cP ± 1.0 Repeatability (%) ± 0.03 ± 0.03 ± 0.03 6 ± 0.03 ± 0.03 ± 0.03 ± 0.03 ± 0.03 FLOW 2" SI (lpm) MATERIALS OF CONSTRUCTION Wetted Parts Port Size 1/4" 1/2" 3/4" 1" 1" HF 1-1/2" 2" 3" Housing Cover 316 SS 316 SS 6061 Al 6061 Al 316 SS 316 SS 6061 Al 6061 Al 316 SS 316 SS 6061 Al 6061 Al 316 SS 316 SS 6061 Al 6061 Al 316 SS 316 SS 6061 Al 6061 Al 316 SS 316 SS 6061 Al 6061 Al 316 SS 316 SS 6061 Al 6061 Al 316 SS 316 SS 6061 Al 6061 Al Spindle Gears Bearings Magnet O-Ring 316 SS 316 SS Fluorosint 500 Neodymium Au Plated Aflas 316 SS Graphalloy 316 SS 316 SS 316 SS LCP 316 SS Graphalloy LCP 316 SS Graphalloy LCP Alnico Alnico Alnico Viton Aflas Viton Aflas Viton Aflas Viton Aflas 316 SS 316 SS Fluorosint Neodymium Ni Plated 316 SS 316 SS Fluorosint Neodymium Ni Plated 316 SS 316 SS Fluorosint Neodymium Ni Plated Viton 316 SS 316 SS Fluorosint Neodymium Ni Plated Viton kele.com 888-397-5353 USA Viton Aflas Viton Aflas Aflas Bolts 316 SS 316 SS 316 SS 316 SS 316 SS 316 SS 316 SS 316 SS NOTE: Upon request, additional O-Ring options are Buna-N and EPDM. March 2014 WE MAKE IT EASY. 333 NEW! FLOW INDUSTRIAL OVAL GEAR METER IOG SERIES ORDERING INFORMATION MODEL IOG 6 DESCRIPTION Industrial Oval Gear Meter PORT SIZE (for 1/4" port size see the 4 part numbers listed below) 050 1/2 inch port 075 3/4 inch port 100 1 inch port HF 1 inch high flow 150 1.5 inch port 200 2 inch port 300 3 inch port HOUSING SS Stainless Steel AL Aluminum CONNECTIONS NPT National Pipe Thread BSP Britsh Standard Pipe 150 150 LB Flange 300 300 LB Flange FLOW METER MOUNT REGISTER STANDARD R0 ILR-700 Local Display w/ Rate and Total T1 ILR-710 Display w/ Scaled Pulse Output T2 ILR-720 Display w/ Dual Scaled Pulse Output T3 ILR-730 Local Display w/ Ananlog Output METER MOUNT NON-SCALED TRANSMITTERS T4 ILR-740 Unscaled Pulse Output T5 ILR-741 Unscaled Pulse Output, Explosion Proof METER MOUNT REGISTER LARGE DISPLAY R1 ER-420 Scalable Rate Flow Counter 115-230 VAC RJ ER-420 Scalable Rate Flow Counter 24 VDC RK ER-420 Scalable Rate Flow Counter, Loop Powered RL ER-500 Standard RM ER-500 Advanced w/ Modbus NO REGISTER or TRANSMITTER RX None IOG 050 SS NPT T1 Example: IOG-050-SS-NPT-T1 1.2 inch port, stainless steel w/ IRL-710 Display w/ Scaled Pulse Output 1/4" Port Size Part Numbers 1/4" IOG, Aluminum, NPT - IOG-025-AL-NPT-01 1/4" IOG, Aluminum, BSP - IOG-025-AL-BSP-01 1/4" IOG, Stainless Steel, NPT - IOG-025-SS-NPT-11 1/4" IOG, Stainless Steel, BSP - IOG-025-SS-BSP-11 334 888-397-5353 USA kele.com WHEN YOU NEED IT RIGHT, RIGHT NOW, CALL KELE. March 2014 NEW! FLOW RECORDALL® COMPOUND SERIES METER RCDL COMPOUND SERIES DESCRIPTION The Badger Meter Recordall Compound Series meters meet or exceed the most recent revision of AWWA Standard C700 and are available in a leadfree bronze alloy. The Compound Series meters comply with the lead-free provisions of the Safe Drinking Water Act, are certified to NSF/ANSI Standards 61 and 372 (Trade Designation: LL-NS) and carry the NSF-61 mark on the housing. All components of the lead-free bronze alloy meter (housing, measuring element, seals, and so on) comprise the certified system. Badger Meter Recordall® Compound Series meters combine two metering technologies in one innovative package. A positive displacement chamber measures low flow, while a turbine chamber records high flow. OPERATION At low flow rates, the Compound Series meter diverts water up through a bypass to the disc chamber. Leaving the chamber’s outlet port, water flows beyond the turbine element and main valve. As the flow rate increases, a pressure differential is created that opens the main valve. The water then flows straight through the turbine chamber. In addition, a portion still flows through the disc chamber before exiting the meter. FEATURES • Offered in four sizes • Patented design that eliminates the need for a trigger valve and maintains crossover accuracy • Permanently sealed, tamper-resistant register or encoder Compound Series Family APPLICATION Use the Recordall Compound meter for measuring potable cold water in commercial and industrial applications where flow is in one direction only. The meter is an ideal choice for facilities that experience rapid and wide fluctuations in water demand, such as hospitals, universities, residential complexes and manufacturing or processing facilities. FLOW METER INSTALLATION The meter is designed for installations where flow is in one direction only. A separate strainer is provided to ensure optimum flow conditioning and protection of the measuring element. Companion flanges for installation of meters on various pipe types and sizes are available in cast iron or NL bronze as an option. 6 • An optional summator can be provided as an integral part of the register assembly. All register options are removable from the meter without disrupting water service • Certifcations: NSF/ANSI Standard 61 Certified, Annex G SPECIFICATIONS Compound Series Model Meter Flanges, Class 150 Typical Operating Range 2" (50 mm) 3" (80 mm) 4" (100 mm) 6" (150 mm) 2" elliptical or round 3" round 4" round 6" round (50 mm) (80 mm) (100 mm) (150 mm) 0.5…200 gpm 0.5…450 gpm 0.75…1000 gpm 0.75…2000 gpm (0.1…45 m3/h) 0.25 gpm (0.06 m3/h) (0.1…102 m3/h) 0.25 gpm (0.06 m3/h) (0.17…227 m3/h) 0.375 gpm (0.09 m3/h) (0.17…454.4 m3/h) 0.375 gpm (0.09 m3/h) Maximum Continuous Flow 170 gpm (38.3 m3/h) 400 gpm (90.3 m3/h) 800 gpm (181.6 m3/h) 1500 gpm (340.5 m3/h) Pressure Loss at Maximum Continuous Flow 5.4 psi at 170 gpm (0.38 bar at 38.3 m3/h) 6.0 psi at 400 gpm (0.41 bar at 90.3 m3/h) 11.0 psi at 800 gpm (0.75 bar at 181.6 m3/h) 9.3 psi at 1500 gpm (0.64 bar at 340.5 m3/h) Crossover Flow Rate, Typical 12 gpm 12 gpm 20 gpm 30 gpm Pressure Loss at Crossover 3.5 psi (0.24 bar) 4.0 psi (0.28 bar) 4.0 psi (0.28 bar) 5.0 psi (0.35 bar) 97% 97% 97% 95% (100% ± 1.5%) Low Flow Registration (97% minimum) Minimum Crossover Accuracy Maximum Operating Pressure 150 psi (10 bar) Maximum Operating Temperature 105° F (41° C) Test Plug March 2014 1-1/2" 2" WE MAKE IT EASY. kele.com 888-397-5353 USA 335 FLOW NEW! RECORDALL® COMPOUND SERIES METER RCDL COMPOUND SERIES DIMENSIONS Compound Series Model 2" Elliptical (50 mm) Meter & Pipe Size 2" (50 mm) Net Weight 45 lb (20.4 kg) Shipping Weight 63 lb (28.5 kg) 3" (80 mm) 4" (100 mm) 6" (150 mm) 3" (80 mm) 4" (100 mm) 6" (150 mm) 71.5 lb (32.4 kg) 85 lb (38.4 kg) 152 lb (68.7 kg) 99.5 lb (45 kg) 120 lb (53.8 kg) 200 lb (90.4 kg) Length (A) 15-1/4" * (387 mm) 17" (432 mm) 20" (508 mm)** 24" (610 mm) Width (B ) 7-3/8" (187 mm) 9-1/4" (235 mm) 9-1/8" (232 mm) 12-3/8" (314 mm) Height (C) 5-7/8" (149 mm) 6-5/8" (168 mm) 7-1/4" (184 mm) 8-7/8" (225 mm) 5/8" (16 mm) 3/4" (19 mm) 7/8" (22 mm) 15/16" (24 mm) 6" (152 mm) 7-1/2" (190.5 mm) 9-1/2" (241 mm) 3-5/8" (92 mm) 4-1/4" (108 mm) 5-3/8" (137 mm) 4 8 8 Flange (D) 6 2" Round (50 mm) Bolt Circle (E) 4-1/2" (114 mm) Centerline (C) to Base (F) Number of Bolts 4-3/4" (121 mm) 2-3/4" (70 mm) 2 4 * Adapter available to increase total length to 17” (432 mm). **Adapter available to increase total length to 24” (610 mm). FLOW Elliptical Flange (2" only) B C F D A E Round Flange B D C F E A ORDERING INFORMATION MODEL UM1-0008-6032 UM1-0008-6034 UM1-0008-6035 UM1-0008-6037 336 888-397-5353 USA DESCRIPTION 2" Compound Meter with Pulse 3" Compound Meter with Pulse 4" Compound Meter with Pulse 6" Compound Meter with Pulse kele.com WHEN YOU NEED IT RIGHT, RIGHT NOW, CALL KELE. March 2014 NEW! FLOW RECORDALL® NUTATING DISC METERS RCDL NUTATING DISC DESCRIPTION The Badger Meter Recordall Model Nutating Disc Series meters meet or exceed the most recent revision of AWWA Standard C700 and are available in a lead-free bronze alloy. The meters comply with the lead-free provisions of the Safe Drinking Water Act, are certified to NSF/ANSI Standards 61 and 372 (Trade Designation: M25-LL) and carry the NSF-61 mark on the housing. All components of the lead-free bronze alloy meter (housing, measuring element, seals, and so on) comprise the certified system. Operation: Water flows through the meter’s strainer and into the measuring chamber where it causes the disc to nutate. The disc, which moves freely, nutates on its own ball, guided by a thrust roller. A drive magnet transmits the motion of the disc to a follower magnet located within the permanently sealed register. The follower magnet is connected to the register gear train. The gear train reduces the disc nutations into volume totalization units displayed on the register or encoder face. Operating Performance: The Recordall Nutating Disc Series meters meet or exceed registration accuracy for the low flow rates (95%), normal operating flow rates (100 ± 1.5%), and maximum continuous operation flow rates as specifically stated in AWWA Standard C700. Industrial RCDL Disc Meters APPLICATION For use in measurement of potable cold water in residential, commercial and industrial services where flow is in one direction only. Connections: Tailpieces/Unions for installations of meters on various pipe types and sizes, including misaligned pipes, are available as an option. FLOW Construction: Recordall Nutating Disc Series meter construction, which complies with ANSI/AWWA standard C700, consists of three basic components: meter housing, measuring chamber, and permanently sealed register. The water meter is available in a lead-free bronze alloy with externally-threaded spuds. A corrosion-resistant engineered polymer material is used for the measuring chamber. 6 Certifications: NSF/ANSI Standards 61 and 372 Certified SPECIFICATIONS Typical Operating Range (100% ± 1.5%) Low Flow (Min. 95.0%) 25 0.5…25 gpm (0.11…5.7 m3/hr) n/a Low Flow (Min. 97.0%) n/a Low Flow (Min. 98.5%) 0.25 gpm (0.057 m3/hr) Maximum Continuous 15 gpm (3.4 m3/hr) Operation Pressure Loss at Maximum 3.5 psi at 15 gpm Continuous Operation (0.24 bar at 3.4 m3/hr) Maximum Operating Temperature Maximum Operating Pressure Measuring Element Available in NL bronze and thermoplastic to Meter Connections fit 0.625" (DN 15mm) spud thread bore diameter sizes Test Plugs March 2014 n/a MODEL 35 70 120 0.75…35 gpm 1.25…70 gpm 2.5…120 gpm (0.17…7.9 m3/hr) (0.28…16 m3/hr) (0.57…27 m3/hr) n/a 0.75 gpm (0.17 m3/hr) 1.25 gpm (0.28 m3/hr) 0.375 gpm n/a n/a (0.085 m3/hr) n/a n/a n/a 25 gpm (5.7 m3/hr) 50 gpm (11.3 m3/hr) 80 gpm (18 m3/hr) 5.0 psi at 25 gpm 6.5 psi at 50 gpm 4.8 psi at 80 gpm (0.37 bar at 5.7 m3/hr) (0.45 bar at 11.3 m3/hr) (0.33 bar at 18 m3/hr) 170 2.5…170 gpm (0.57…39 m3/hr) 1.5 gpm (0.34 m3/hr) n/a n/a 100 gpm (23 m3/hr) 3.3 psi at 100 gpm (0.23 bar at 23 m3/hr) 80°F (26°C) 150 psi (10 bar) Nutating disc, positive displacement Available in NL bronze Available in NL bronze 1.5" AWWA two-bolt el- 2.0" AWWA two-bolt and engineered polymer and engineered polymer liptical flange, drilled or elliptical flange, drilled to fit 0.75" (DN 20 to fit 1.0" (DN 25 mm) 1.5…11.5 NPT internal or 2…11.5 NPT internal mm) spud thread bore spud thread bore pipe threads pipe threads diameter sizes diameter sizes Optional 1.0" NPT test 1.0" NPT test plug (TP) plug (TP) available on n/a n/a available on elliptical elliptical long and short long and short versions versions WE MAKE IT EASY. kele.com 888-397-5353 USA 337 FLOW NEW! RECORDALL® NUTATING DISC METERS RCDL NUTATING DISC DIMENSIONS Meter Size Meter Model 5/ " (15 mm) 8 3/ " (20 mm) 4 25 1" (25 mm) 1-1/2" (40 mm) 70 35 120 EL Hex 120 EL, TP 170 EL Hex 170 EL, TP 2" (50 mm) A Laying Length 1 7- /2" (190 mm) 7-1/2" (190 mm) 10-3/4" (273 mm) B Height Reg. 4-15/16" (125 mm) 5-1/4" (133 mm) 6-1/2" (165 mm) C Centerline Base Width 1-11/16" (42 mm) 4-1/4" (108 mm) 1-5/8" (41 mm) 5" (127 mm) 2-5/16" (59 mm) 7-3/4" (197 mm) Approx. Shipping Weight 1 4- /2 lb (2 kg) 5-1/2 lb (2.5 kg) 11-1/2 lb (5.2 kg) 12-5/8" (321 mm) 7" (178 mm) 2-3/8" (60 mm) 8-3/4" (222 mm) 19 lb (8.6 kg) 15-1/4" (387 mm) 8" (203 mm) 2-7/8" (73 mm) 9-1/2" (241 mm) 30 lb (13.6 kg) 6 FLOW Meter Spud and Connection Sizes Size Designation x “L” Laying Length 5/8" x 7-1/2" “B” Bore Dia. 5/8" Coupling Nut and Spud Thread 3/4" (5/8") Tailpiece Pipe Thread (NPT) 1/2" Meter Spud and Connection Sizes Size Designation x 3/4" 3/4" 3/4" x 1" x x x “L” Laying Length “B” Bore Dia. 7-1/2" 9" 9" 3/4" 3/4" 3/4" Coupling Nut and Spud Thread 1" (3/4") 1" (3/4") 1-1/4" (1") Tailpiece Pipe Thread (NPT) 3/4" 3/4" 1" Meter Spud and Connection Sizes Size Designation 1" x “L” Laying Length “B” Bore Dia. x 10-3/4" 1" Coupling Nut and Spud Thread 1-1/4" (1") Tailpiece Pipe Thread (NPT) 1" ORDERING INFORMATION MODEL UM1-0008-6014 UM1-0007-5863 UM1-0007-2649 UM1-0008-6016 UM1-0008-6017 338 888-397-5353 USA DESCRIPTION Model 25 Pulse Water Meter Model 35 Pulse Water Meter Model 70 Pulse Water Meter Model 120 Pulse Water Meter Model 170 Pulse Water Meter kele.com WHEN YOU NEED IT RIGHT, RIGHT NOW, CALL KELE. March 2014 NEW! FLOW RECORDALL® TURBO SERIES METERS RCDL TURBO SERIES DESCRIPTION The Badger Meter Recordall Turbo Series meters meet or exceed the most recent revision of AWWA Standard C701 Class II Standards and are available in a lead-free bronze alloy for sizes 1-1/2" through 10" and cast iron for 12" meters. Turbo Series meters comply with the lead-free provisions of the Safe Drinking Water Act. Sizes 1-1/2" through 10" meters are also certified to NSF/ANSI Standards 61 and 372 (Trade Designation: Turbo Series LL-NS) and carry the NSF-61 mark on the housing. All components of the lead-free alloy meter (housing, measuring element, seals and so on) comprise the certified system. Operation & Performance: Direct magnetic drive is achieved when the magnet carrier is driven by a gear train coupled to the rotor. The gear train consists of two sets of gears connected by a vertical transmission shaft. One gear set is at the magnet carrier, the other is a worm gear set at the rotor shaft. When water flows into the Turbo Series meter measuring element, it contacts the multi-vaned rotor. The resulting rotor rotation is then transmitted by magnetic coupling to a sealed register or encoder. The direct magnetic drive is built to provides a reliable meter-to-registration coupling. 6 Industrial Turbo Meters APPLICATION • Models 160 through 6200 are designed for 1-1/2" through 12" applications • Direct coupled turbine based on an exclusive "floating rotor"design that reduces bearing friction—and associated wear and tear • Low pressure loss for improved system efficiency • Exceptional registration accuracy across low flow rate, normal operating flow rate and maximum continuous operation flow • Permanently sealed, tamper-resistant register or encoder • Integral strainer option for sizes 1-1/2" through 4" help protect your system from damaging debris and related downtime • NSF/ANSI Standards 61 and 372 Certified Recordall Turbo Series meters are designed for cold water, commercial and industrial applications where flows are consistent medium to high flows. Applications include hotels, apartment buildings, irrigations centers and manufacturing and processing plants. Turbo Series meters help reduce day-today maintenance costs while delivering accurate and efficient performance. FLOW FEATURES SPECIFICATIONS Turbo Series Model Meter Flanges AWWA 125 Pound Class Typical Operating Range (100% ± 1.5%) Typical Low Flow (95% min.) Max. Continuous Flow Maximum Intermittent Flow Pressure Loss at Max. Continuous Flow Pressure Loss at Max. Continuous Flow: With Integral Strainer Max. Operating Pressure Max. Operating Temperature Optional Integral Strainer Optional External Strainer Test Plug March 2014 160 1-1/2" (40 mm) 200 2" (50 mm) 450 3" (80 mm) 1000 4" (100 mm) 2000 6" (150 mm) 3500 8" (200 mm) 5500 10" (250 mm) 6200 12" (300 mm) Elliptical Elliptical or Round Round Round Round Round Round Round AWWA 125 lb class 4…200 gpm (0.9…45.4 m3/h) 2.5 gpm (0.6 m3/h) 160 gpm (36 m3/h) 200 gpm (45.4 m3/h) 3.8 psi (0.26 bar) 4…310 gpm (0.9…70.4 m3/h) 2.5 gpm (0.6 m3/h) 200 gpm (45.4 m3/h) 310 gpm (70.4 m3/h) 3.1 psi (0.21 bar) 5…550 gpm (1.1…124.9 m3/h) 4 gpm (0.9 m3/h) 450 gpm (102.2 m3/h) 550 gpm (124.9 m3h) 1.8 psi (0.12 bar) 10…1250 gpm (2.3…284 m3/hr) 6 gpm (1.4 m3/h) 1000 gpm (227.1 m3/h) 1250 gpm (284 m3h) 7.3 psi (0.50 bar) 20…2500 gpm (4.5…568 m3/h) 12 gpm (2.7 m3/h) 2000 gpm (454 m3/h) 2500 gpm (568 m3/h) 4.8 psi (0.33 bar) 30…4500 gpm (6.8…1022 m3/h) 20 gpm (4.5 m3/h) 3500 gpm (795 m3/h) 4500 gpm (1022 m3/h) 2.5 psi (0.17 bar) 50…7000 gpm (11.4…1590 m3/h) 30 gpm (6.8 m3/h) 5500 gpm (1250 m3/h) 7000 gpm (1590 m3h) 1.6 psi (0.11 bar) 90…8800 gpm (20.5…1998 m3/h) 65 gpm (14.8 m3/h) 6200 gpm (1408 m3/h) 8800 gpm (1988 m3/h) 0.8 psi (0.05 bar) 9.9 psi (0.68 bar) 8.3 psi (0.57 bar) 5 psi (0.43 bar) 17.8 psi (1.2 bar) — 150 psi (10 bar) 120° F (49° C) Built into inlet end. Removable cover plate permits access to strainer for cleaning. — — Available for Models 200, 450, 1000, 2000, 3500, 5500 and 6200. Standard with integral strainer; optional for other models. Optional for Models 2000 and 3500. WE MAKE IT EASY. kele.com — 888-397-5353 USA 339 NEW! FLOW RECORDALL® TURBO SERIES METERS RCDL TURBO SERIES DIMENSIONS OF METERS WITH INTEGRAL STRAINER 6 Turbo Series Model 160 200 200 450 1000 Elliptical Elliptical Round Round Round Meter & Pipe Size 1-1/2" (40 mm) 2" (50 mm) 2" (50 mm) 3" (80 mm) 4" (100 mm) Net Weight 14.3 lb (6.5 kg) 24 lb (11 kg) 26 lb (12 kg) 49 lb (22 kg) 60 lb (27.22 kg) Shipping Weight 16.8 lb (7.6 kg) 28 lb (13 kg) 30 lb (14 kg) 55 lb (25 kg) 70 lb (31.75 kg) Number of Bolts 2 2 4 4 8 NPT Test Port & Test Plug (Standard) 1" (25.4 mm) 1-1/2" (40 mm) 1-1/2" (40 mm) 2" (50 mm) 2" (50 mm) Length (A) 13" (330 mm) 17" (432 mm) 17" (432 mm) 19" (483 mm) 23" (584 mm) Width (B ) 5-7/32" (133 mm) 5-27/32" (148 mm) 6" (152 mm) 7-1/2" (191 mm) 9" (229 mm) Height (C) 6-9/32" (159 mm) 6-1/2" (165 mm) 7-3/32" (180 mm) 8-15/16" (227 mm) 9-21/32" (245 mm) Flange (D) FLOW Meter Flanges 51/64" (20 mm) 27/32" (47 mm) 5/8" (16 mm) 27/32" (21 mm) 13/16" (21 mm) Bolt Circle (E) 4" (102 mm) 4-1/2" (114 mm) 4-3/4" (121 mm) 6" (152 mm) 7-1/2" (191 mm) Centerline (F) 1-27/32" (47 mm) 2-1/16" (52 mm) 2-5/8" (67 mm) 3-19/32" (91 mm) 4-5/16" (109 mm) ORDERING INFORMATION MODEL UM1-0007-6445 UM1-0008-6020 UM1-0008-6021 UM1-0008-6023 UM1-0008-6024 UM1-0008-6025 UM1-0008-6026 340 888-397-5353 USA DESCRIPTION 1 1/2" Turbine Water Meter with Pulse 2" Turbine Water Meter with Pulse 3" Turbine Water Meter with Pulse 4" Turbine Water Meter with Pulse 6" Turbine Water Meter with Pulse 8" Turbine Water Meter with Pulse 10" Turbine Water Meter with Pulse kele.com WHEN YOU NEED IT RIGHT, RIGHT NOW, CALL KELE. March 2014 NEW! FLOW INSERTION TYPE AIRFLOW SENSING ELEMENT FE-1000 SERIES DESCRIPTION The Paragon Controls FE-1000 insertion type airflow sensing element is designed for quick, easy installation through a small cutout in the existing ductwork. Where multiple elements are required for proper duct traversing, the output ports are manifolded together, external to the ductwork. Each element is furnished complete with mounting hardware, sealing gaskets and all brass compression fittings required to manifold the elements together. FEATURES • Multiple total and static pressure sensing ports along the length of the element • Averaging internal manifold • Insensitive to flow angle variations of as much as ±20° when faced in the normal direction of flow • ±2% accuracy throughout the velocity rages of 100 fpm and over 6 FE-1000 SPECIFICATIONS Connections Within 2% of actual flow (even in moderately turbulent flows) with approach angle variation of ±20°, when installed in accordance with published recommendations 1/4" compression, suitable for use with thermoplastic or copper tubing; thermoplastic tubing requires the use of tubing inserts, which are supplied with the fittings Velocity Range 100 to 10,000 fpm Operating Temperature350°F (177°C) continuous operation (in air) 400°F (204°C) intermittent operation (in air) Operating Humidity 0 to 100% RH, non-condensing Materials Of Construction 6063-T5 anodized aluminum (standard) Warranty 1 year FLOW Accuracy ORDERING INFORMATION MODEL FE-1000 March 2014 DESCRIPTION Insertion type airflow sensing element DIMENSIONS 1 Inches 2 Millimeters DUCT CONFIGURATION 1 Rectangular 2 Circular 3 Oval ELEMENT LENGTH (SPECIFY) INTERNAL INSULATION (SPECIFY) MATERIAL TYPE 1 Aluminum (standard) MOUNTING CONFIGUATION 1 Insertion (standard) 2 Internal Mount 3 Bayonet Tip TAKEOFF CONFIGURATION 1 1/8-27 Female NPT (standard) WE MAKE IT EASY. kele.com 888-397-5353 USA 341 FLOW NEW! FAN INLET AIRFLOW SENSING ELEMENT FE-1050 SERIES DESCRIPTION The Paragon Controls FE-1050 is an airflow measuring element assembly specifically designed for installation in the inlet cone of centrifugal fans or inlet bell of vane-axial fans. The design of these primary elements provides a means of accurate measurement of fan capacity along with ease of installation. Each assembly is complete with two airflow measuring elements and pivot mounting hardware. FEATURES • Multiple total and static pressure sensing ports along the length of the element • Averaging internal manifold • Insensitive to flow angle variations of as much as ±20° when faced in the normal direction of flow • ±2% accuracy throughout the velocity ranges of 100 fpm and over FE-1050 FLOW 6 SPECIFICATIONS Accuracy Connections Velocity Range 342 Within 2% of actual flow when installed in accordance with published recommendations 1/4" compression, suitable for use with thermoplastic or copper tubing; thermoplastic tubing requires the use of tubing inserts, which are supplied with the fittings 100 to 8,000 fpm 888-397-5353 USA kele.com Operating Temperature350°F (177°C) continuous operation (in air) 400°F (204°C) intermittent operation (in air) Operating Humidity 0 to 100% RH, non-condensing Materials Of Construction 6063-T5 anodized aluminum (standard) Warranty 1 year WHEN YOU NEED IT RIGHT, RIGHT NOW, CALL KELE. March 2014 NEW! FLOW FAN INLET AIRFLOW SENSING ELEMENT FE-1050 SERIES DIMENSIONS 6 FLOW Note: The 0.585 inch diameter probe is used for minimum fan inlets less than or equal to 28 inches and the 1 inch diameter probe is used for minimum fan inlets greater than 28 inches. ORDERING INFORMATION MODEL FE-1050 March 2014 DESCRIPTION Fan inlet airflow sensing element DIMENSIONS 1 Inches 2 Millimeters INLET CONFIGURATION 1 Single inlet (SWSI) 2 Double inlet (DWDI) MOUNTING CONFIGUATION 1 Minimum inlet diameter (standard) 2 Mid-bell installation DIAMETER OF SENSING PLANE (SPECIFY) MATERIAL TYPE 1 Aluminum WE MAKE IT EASY. kele.com 888-397-5353 USA 343 FLOW MEASURING AIRFLOW Averaging Differential Pressure Devices To take some of the guesswork out of determining average duct velocity, an averaging tube may be used. An averaging tube operates basically the same way as a pitot tube to determine average duct velocity pressure, except instead of measuring one point within the duct, the averaging tube measures multiple points to determine a true average velocity. As an added benefit, some averaging tubes are designed so that the differential pressure measured is two to three times the actual velocity pressure. This amplification is accomplished by the shape and design of the tube and results in greater resolution and the ability to measure lower air velocities. 6 NEW! In Summary • Only the average duct velocity and duct cross-section area must be known to determine airflow. • By piping the total pressure to the high-pressure port and the static pressure to the low-pressure port of a differential pressure transmitter, the velocity pressure will be measured. • When the duct center velocity is measured with a pitot tube, the average velocity will be approximately 90% of the measured velocity. • By using an averaging tube, the average duct velocity may be measured directly. The averaging tube may also amplify pressure for greater resolution and higher accuracy at low flow rates. Flow coefficients for use with averaging tubes will be provided by the manufacturer. FLOW • Always install airflow measurement devices at least 7.5 duct diameters downstream and 1.5 diameters upstream of anything in the duct that could cause turbulence. QUICK TIPS (for use with pitot tubes only) Device Placement in the Duct When measuring airflow with either a pitot tube or an averaging tube, the best results will be obtained when the flow measuring device is located at least 7.5 duct diameters downstream and 1.5 diameters upstream from any disturbance (elbows, obstructions, etc.). Also, for best results, straightening vanes may be used 1.5 to 5 diameters upstream of the flow measuring device. FIGURE 2. FLOW COEFFICIENTS FOR DIFFERENTIAL PRESSURE TRANSMITTERS (for use with pitot tubes only) Differential Pressure Transmitter Range "W.C. 0 .1 0 .2 0 .3 0 .5 1 .0 2 .0 3 .0 5 .0 344 Maximum Air Velocity (fpm) Flow Coefficient (Cf) 1265 1790 2190 2830 4000 5660 6930 8950 316 448 549 708 1000 1420 1733 2240 888-397-5353 USA kele.com By applying the two simple facts below, air velocity may be quickly estimated in the field . Fact 1. 4000 fpm velocity = 1" velocity pressure Fact 2. Velocity pressure varies as the flow squared or 2 P 2 = V2 or V2 = P2 P1 V1 V1 P1 ( ) Example: If a velocity pressure is known, the velocity may be calculated by using 4000 fpm and 1" differential as V1 and P1 . Assume the velocity pressure is 0 .25" . What is the air velocity? or V2 V 2 = P2 V1 P1 4000 or V2 = 2000 fpm = 0 .25 1 If a velocity is known, velocity pressure may be calculated in a similar manner . Assume velocity is 1000 fpm, what is velocity pressure? ( ) 2 or P2 P2 = V2 P1 V1 1 or P2 = 0 .0625" W .C . WHEN YOU NEED IT RIGHT, RIGHT NOW, CALL KELE. ( ) = 1000 4000 2 March 2014