HCT SERIES Features • • • • • • • • • • • DC, AC Hall Effect Current Transducers Open Loop and Closed Loop operation Modes Wide range of primary current measurement s, from 5 A up to 1200 A RMS. Wide range of frequencies Band Width, Typically from 0 up to 50,100 and 200 kHz. Useful to measure Current spikes, overshoots and ringing effects. Bipolar and Unipolar Power Supply Different ways for connection, PTH or standard connector Output voltage signals typically for Open Loop Ones, Current signal outputs for closed loop ones Customized outputs Possibilities UL94V-0 material RoHS compliant Application • • • • General Industrial applications for current Monitoring Current measure on input stage batteries inverters UPS Applications (Uniterrumpibles Power Supplies) General using in Switched Power Supplies, for digital control systems General Electrical specifications. Closed Loop Devices Nominal Measuring (A Current (A Current RMS) DC) Secondary Supply Accuracy ( Linearity (See Mounting See Note 1) Note 2) Output Signal Voltage (V) Isolation (V AC 50Hz) Code Family HCT-25A05 A05 25 ±50 ± 25 mA ±15 ±0.5% 0,20% PCB 2500 HCT-35A05 A05 35 ±70 ± 35 mA ±15 ±0.5% 0,20% PCB 2500 HCT-100LP LP 100 ±300 ± 50 mA ±12-18 ±0.5% 0,10% PCB 3000 HCT-200LP LP 200 ±600 ± 100 mA ±12-18 ±0.5% 0,10% PCB 3000 HCT-50AP AP 50 ± 150 ± 50mA ± 12-18 ± 0,5% 0,10% PCB 3000 HCT-100AP AP 100 ± 300 ± 50mA ± 12-18 ±0,5% 0,10% PCB 3000 HCT-200AP AP 200 ± 600 ±100mA ± 12-18 ±0,5% 0,10% PCB 3000 HCT-300LTP LTP 300 ±900 ± 150 mA ±12-18 ±0.5% 0,10% Connector 6000 HCT-10PX5 PX5 10 ±22 3.5V@+Inom / 1.5V@-Inom 5 ±0.5% 0,10% PCB 3000 HCT-30PX5 PX5 30 ±66 3.5V@+Inom / 1.5V@-Inom 5 ±0.5% 0,10% PCB 3000 HCT-1000SH SH 1000 ±3000 ± 200 mA ±15-24 ±0.1% 0,10% Connector 4000 HCT-2000LF LF 2000 ±5000 ± 400 mA ±15-24 ±0.2% 0,10% Connector 4000 Specification is subjected to change without prior notice PREMO 2010 Page 1 HCT SERIES Notes (1) Accuracy levels at Nominal current, measured at room temperature over a 1 Ohm, non-inductive precision burden resistor ( for all the model except PX5 ones). (2)Typical linearity response, measuring from 10% to 100% of nominal current (3) Individual data sheet for each transducer available on Premo Website. All data are related to room temperature, 25ºC ± 2 ºC. General Electrical specifications. Open Loop Devices Code Nominal Current (A RMS) Measuring Secondary Current (A Output Signal DC) HCT-100BP1 HCT-200BP1 HCT-600BP1 HCT-100BP2 HCT-200BP2 HCT-600BP2 100 200 600 100 200 600 ±300 ±600 ±1000 ±300 ±600 ±1000 ±4V ±4V ±4V ±4V ±4V ±4V ±15 ±15 ±15 ±15 ±15 ±15 ±1% ±1% ±1% ±1% ±1% ±1% HCT-50BP5 50 ±100 3.5V@+Inom / 1.5V@-Inom 5 HCT-100BP5 100 ±200 3.5V@+Inom / 1.5V@-Inom HCT-500F 500 ±1200 HCT-800F 800 HCT-1000F Supply Voltage (V) Accuracy (See Linearity ( Note 1) See Note 2) Mounting Isolation (V AC 50Hz) <1% <1% <1% <1% <1% <1% PCB PCB PCB PCB PCB PCB 2500 2500 2500 2500 2500 2500 ±1% <1% PCB 3000 5 ±1% <1% PCB 3000 ±4V ±15 ±1% < 1% Connector 5000 ±1600 ±4V ±15 ±1% < 1% Connector 5000 1000 ±2000 ±4V ±15 ±1% < 1% Connector 5000 HCT-100N 100 ±300 ±4V ±15 ±1% < 1% Connector 3000 HCT-300N 300 ±900 ±4V ±15 ±1% <1% Connector 3000 HCT-1000K 1000 ±2000 ±4V ±15 ±1% < 1% Connector 6000 HCT-1200K 1200 ±2500 ±4V ±15 ±1% <1% Connector 6000 HCT-50LB 50 ±150 ±4V ±15 ±1% < 1% Connector 2500 HCT-100LB 100 ±200 ±4V ±15 ±1% <1% Connector 2500 Notes (1)Accuracy levels at Nominal current, measured at room temperature over a 10 kOhm burden resistor . (2)Typical linearity response, measuring from 10% to 100% of nominal current (3) Individual data sheet for each transducer available on Premo Website. All data are related to room temperature 25ºC ± 2 ºC. Recommended installation Diagrams. Closed Loop Devices Open Loop Devices VCC + Vcc + HCT Vout HCT 0V M Rb - -VCC Vout R >10k - Vcc GND Specification is subjected to change without prior notice PREMO 2010 Page 2 HCT SERIES Typical Accuracy Vs Primary Current Range and Output transfer function. In the graphs showed as per below accuracy levels reached with each family are presented. The curves present the typical average values. Ideal transfer function input current vs output signals are presented as well. A05 FAMILY A05 Output Transfer Function Relative Error A05 Family 800 Output V oltage (mV) % Er ror of Measure 2 1,5 1 0,5 0 0 50 100 150 600 400 200 HCT-25A05 0 -200 HCT-35A05 -400 -600 -800 200 -200 -150 -100 -50 % of N ominal Current 0 50 100 150 200 % of Nominal Current Data at 25ºC. Burden resistor used 10 Ohm ± 0.2 %. Vcc ± 15V LP FAMILY LP Output Transfer Function Relative Error LP Family 4 3 Output V oltage (V) % Er ror of Measure 2 1,5 1 0,5 2 HCT-100LP 1 0 -1 -2 HCT-200LP -3 0 0 50 100 150 200 250 -4 300 -300 -200 -100 % of N ominal Current 0 100 200 300 200 300 % of Nominal Current Data at 25ºC. Burden resistor used 10 Ohm ± 0.2 %. Vcc ± 15V AP FAMILY AP Output Transfer Function Relative Error AP Family 4 3 Output V oltage (V) % Er ror of Measure 2 1,5 1 0,5 2 HCT-50 &100AP 1 0 -1 -2 HCT-200AP -3 0 0 50 100 150 200 250 300 % of N ominal Current -4 -300 -200 -100 0 100 % of Nominal Current Data at 25ºC. Burden resistor used 10 Ohm ± 0.2 %. Vcc ± 15V Specification is subjected to change without prior notice PREMO 2010 Page 3 HCT SERIES LTP FAMILY LTP Output Transfer Function Relative Error LTP Family Output V oltage (V) % Er ror of Measure 2 1,5 1 0,5 0 0 50 100 150 200 250 300 5 4 3 2 1 0 -1 -2 -3 -4 -5 -300 -200 % of N ominal Current -100 0 100 200 300 % of Nominal Current Data at 25ºC. Burden resistor used 10 Ohm ± 0.2 %. Vcc ± 15V PX5 FAMILY Relative Error PX5 Family PX5 Output Transfer Function 1,75 Output V oltage (V) % Er ror of Measure 2 1,5 1,25 1 0,75 0,5 0,25 0 0 20 40 60 80 100 120 140 5 4,5 4 3,5 3 2,5 2 1,5 1 0,5 0 -150 -100 % of N ominal Current -50 0 50 100 150 % of Nominal Current Data at 25ºC. Vcc = 5 V LF & SH FAMILY LF & S Output Transfer Function 15 1 0,9 0,8 0,7 0,6 0,5 0,4 0,3 0,2 0,1 0 Output V oltage (V) % Er ror of Measure Relative Error LF & S Family 0 50 100 150 200 250 300 % of N ominal Current 10 5 SH 0 -5 LF -10 -15 -300 -200 -100 0 100 200 300 % of Nominal Current Data at 25ºC. Burden Resistor 10 Ohm ± 0.2% Vcc = ± 24 V Specification is subjected to change without prior notice PREMO 2010 Page 4 HCT SERIES BP1 & BP2 FAMILY BP1 & BP2 O utput Transfer Function 15 Output V oltage (V) % Er ror of Measure Relative Error BP1 & BP2 Family 2,25 2 1,75 1,5 1,25 1 0,75 0,5 0,25 0 HCT-600BP1&BP2 HCT-100BP1&BP2 HCT-200BP1&BP2 0 50 100 150 200 250 10 5 HCT-600BP1&BP2 0 -5 -10 HCT-100BP1&BP2 HCT-200BP1&BP2 -15 300 -300 -200 -100 % of N ominal Current 0 100 200 300 % of Nominal Current Data at 25ºC. R load 10 kOhm ± 5 % Vcc = ± 15 V BP5 FAMILY BP5 Output Transfer Function Relative Error BP5 Family 1,5 Output V oltage (V) % Er ror of Measure 1,75 1,25 1 0,75 0,5 0,25 0 0 50 100 150 200 5 4,5 4 3,5 3 2,5 2 1,5 1 0,5 0 -200 -150 -100 % of N ominal Current -50 0 50 100 150 200 % of Nominal Current Data at 25ºC. R load 10 kOhm ± 5 % Vcc = ± 15 V F FAMILY Relative Error F Family F Output Transfer Function 15 Output V oltage (V) % Er ror of Measure 2 1,5 HCT-1000F 1 0,5 HCT-500,800F 0 0 50 100 150 200 250 % of N ominal Current 300 10 5 HCT-1000F 0 -5 HCT-500,800F -10 -15 -300 -200 -100 0 100 200 300 % of Nominal Current Data at 25ºC. R load 10 kOhm ± 5 % Vcc = ± 15 V Specification is subjected to change without prior notice PREMO 2010 Page 5 HCT SERIES N FAMILY Relative Error N Family N Output Transfer Function 15 1,75 Output V oltage (V) % Er ror of Measure 2 1,5 1,25 1 0,75 0,5 0,25 0 0 50 100 150 200 250 10 5 0 -5 -10 -15 300 -300 -200 -100 % of N ominal Current 0 100 200 300 % of Nominal Current Data at 25ºC. R load 10 kOhm ± 5 % Vcc = ± 15 V K FAMILY K Output Transfer Function Relative Error K Family 15 Output Voltage (V) % Er ror of Measure 2 1,5 HCT-1000K 1 0,5 HCT-1200K 0 0 50 100 150 200 250 10 5 HCT-1000K 0 HCT-1200K -5 -10 -15 300 -300 -200 % of N ominal Current -100 0 100 200 300 200 300 % of Nominal Current Data at 25ºC. R load 10 kOhm ± 5 % Vcc = ± 15 V LB FAMILY LB Output Transfer Function 15 2,25 2 1,75 1,5 1,25 1 0,75 0,5 0,25 0 Output V oltage (V) % Er ror of Measure Relative Error LB Family HCT-100LB HCT-50LB 0 50 100 150 200 % of N ominal Current 250 300 10 5 HCT-100LB 0 -5 -10 HCT-50LB -15 -300 -200 -100 0 100 % of Nominal Current Data at 25ºC. R load 10 kOhm ± 5 % Vcc = ± 15 V Specification is subjected to change without prior notice PREMO 2010 Page 6 HCT SERIES Dimensions A05 LP 1 5 13-0.8X0.8 - 10 - + + M /P TBC 125/200LP LTP PX5 TBC0 - - 25P 5 41 3 34 45 + M 34 45 20,5 0,2 Ø2 5 24,5 1 Ø3, 3 34 5 1 6 7 8 9 6 7 8 9 19 4 (See pin-out on individual data sheet) S LF +M - + + M - Specification is subjected to change without prior notice IS RM M _ + 0 - PREMO 2010 Page 7 HCT SERIES BP2 BP1 BP2 BP1 GI N GI N OFS OFS 43 21 1 2 43 PI NS 1 2 3 4 BP5 +15V - 15V OUTPUT GND F GI N OFS +- OFS GI N OG 43 21 pi n connect ed 1 2 3 4 N +5V PI N GND + O G OUT 2. 5V +15V - 15V OUT GND K TKC- N +- OG GINOFS 1 +15V 2 - 15V 3 OUT GI N 1 4 OFS 4 GND Specification is subjected to change without prior notice 端子 接线 + O G +15V -15V 输出 地 PREMO 2010 Page 8 HCT SERIES LB AP (50&100) TBC50/ 100AP GI N OFS 5 1 mount i ng: M2. 5X6. 0 Ter mi nal pi n PI N 1 +15V - 15V 2 3 OUT 4 GND 5 NC AP (200) TBC125/ 200AP mount i ng: M2. 5X6. 0 Packaging Antistatic trays with carton grids in carton box Specification is subjected to change without prior notice PREMO 2010 Page 9