Drawings/Spec Sheet - UTC Aerospace Systems

advertisement
2-Channel Indirect Lighting Controller
MSM282
Product Description
The MSM282 is a 2-channel indirect lighting controller that
consists of two (2) individual channels and interfaces with lighting
modules using control signals. It is designed to operate with
indirect lighting modules with control signal inputs. This module
provides the proper on/off and bright/dim output for indirect
lighting.
Features
The following list provides an overview of features for the
MSM282:
q
q
q
q
q
q
Lightweight, compact size
Solid state circuitry
Set/reset functions
Oxygen mask system input
On/off output
Bright/dim output
Installation Guidelines
1.
2.
Application Notes
1.
The MSM282 is a 2-channel (CKT1 and CKT2) indirect
lighting controller. When a channel is switched on, the
corresponding indirect lights may be dimmed or brightened.
The set function initializes the indirect lights to the ON
condition and full bright upon power up. The reset line
initializes the indirect lights to the OFF condition upon power
up. These functions are activated when a ground input signal
is present on the set and reset pins.
The oxygen mask input will override any setting and turn the
CKT2 indirect lights to ON and BRIGHT. This feature
complies with federal regulations concerning emergency
lighting. Oxygen mask input is provided to set CKT2 lights
only to the ON position when a momentary ground is applied
to the oxygen mask set input. A momentary ground on the
set or reset pin will activate the set/reset functions.
The indirect lights on/off output will toggle each time a switch
input has been received. The bright/dim output will toggle
each time a switch input is received only if the corresponding
circuit is ON. Each time the lights are toggled to the ON
position, the bright/dim output will output +28 VDC.
2.
3.
4.
+28VDC
On/Off Switch
Brt/Dim Switch
On/Off Status Out
Brt/Dim Status Out
½ MSM282
Logic
Oxgen Mask Set
Out
Technical Specifications
Electrical
Power
Current Rating
Relay Ratings
Mechanical
Drawings
521980 Rev IR
Dimensions
(l x w x h)
Weight
200 mA @ +28 VDC
(internal circuitry)
5A DC per channel
MAXIMUM
+24 VDC Coil,
5A 250 VAC,
5A +30 VDC
5.0" x 5.0" x 1.0"
12.7cm x 12.7cm x 2.54cm
0.5 lb / 0.23 kg
Description
MSM282 Outline Drawing
Document # 530122A – Revision History
Date
Description
8/1998
Initial Release
3/2000
Overall Update – ECN # 4771
On/Off Output
BRT/Dim
Relay
In
Set
Reset
4.
Level
IR
A
On/Off
Relay
In
Out
3.
All power, signal, and ground wires are 22 AWG, MINIMUM.
Protect power wires with circuit breakers or fuses located
close to the electrical power bus.
Ensure that power and ground are applied only where
required.
The unit shall NOT be mounted to the skin of the aircraft.
Brt/Dim Output
PROPRIETARY NOTICE
Despite any copyright notice, this data and information
disclosed herein contains confidential, proprietary designs owned
by Audio International, Incorporated. Neither this data nor the data
contained herein shall be reproduced, used, or disclosed to
anyone without the written authorization of Audio International, Inc.
Ground
Audio International, Inc. • 7300 Industry Drive, N Little Rock, AR 72117 • Phone 501-955-2929 / Fax 501-955-2988 / www.audiointl.com
Download