2-Channel Indirect Lighting Controller MSM282 Product Description The MSM282 is a 2-channel indirect lighting controller that consists of two (2) individual channels and interfaces with lighting modules using control signals. It is designed to operate with indirect lighting modules with control signal inputs. This module provides the proper on/off and bright/dim output for indirect lighting. Features The following list provides an overview of features for the MSM282: q q q q q q Lightweight, compact size Solid state circuitry Set/reset functions Oxygen mask system input On/off output Bright/dim output Installation Guidelines 1. 2. Application Notes 1. The MSM282 is a 2-channel (CKT1 and CKT2) indirect lighting controller. When a channel is switched on, the corresponding indirect lights may be dimmed or brightened. The set function initializes the indirect lights to the ON condition and full bright upon power up. The reset line initializes the indirect lights to the OFF condition upon power up. These functions are activated when a ground input signal is present on the set and reset pins. The oxygen mask input will override any setting and turn the CKT2 indirect lights to ON and BRIGHT. This feature complies with federal regulations concerning emergency lighting. Oxygen mask input is provided to set CKT2 lights only to the ON position when a momentary ground is applied to the oxygen mask set input. A momentary ground on the set or reset pin will activate the set/reset functions. The indirect lights on/off output will toggle each time a switch input has been received. The bright/dim output will toggle each time a switch input is received only if the corresponding circuit is ON. Each time the lights are toggled to the ON position, the bright/dim output will output +28 VDC. 2. 3. 4. +28VDC On/Off Switch Brt/Dim Switch On/Off Status Out Brt/Dim Status Out ½ MSM282 Logic Oxgen Mask Set Out Technical Specifications Electrical Power Current Rating Relay Ratings Mechanical Drawings 521980 Rev IR Dimensions (l x w x h) Weight 200 mA @ +28 VDC (internal circuitry) 5A DC per channel MAXIMUM +24 VDC Coil, 5A 250 VAC, 5A +30 VDC 5.0" x 5.0" x 1.0" 12.7cm x 12.7cm x 2.54cm 0.5 lb / 0.23 kg Description MSM282 Outline Drawing Document # 530122A – Revision History Date Description 8/1998 Initial Release 3/2000 Overall Update – ECN # 4771 On/Off Output BRT/Dim Relay In Set Reset 4. Level IR A On/Off Relay In Out 3. All power, signal, and ground wires are 22 AWG, MINIMUM. Protect power wires with circuit breakers or fuses located close to the electrical power bus. Ensure that power and ground are applied only where required. The unit shall NOT be mounted to the skin of the aircraft. Brt/Dim Output PROPRIETARY NOTICE Despite any copyright notice, this data and information disclosed herein contains confidential, proprietary designs owned by Audio International, Incorporated. Neither this data nor the data contained herein shall be reproduced, used, or disclosed to anyone without the written authorization of Audio International, Inc. Ground Audio International, Inc. • 7300 Industry Drive, N Little Rock, AR 72117 • Phone 501-955-2929 / Fax 501-955-2988 / www.audiointl.com