POWER CONVERTERS CLAMPS OTHER PRODUCTS ELECTRONIC BOARDS HEATSINKS TRIGGERING BOARDS FOR THYRISTORS The image cannot be display ed. Your computer may not hav e enough memory to open the image, or the image may hav e been corrupted. Restart y our computer, and then open the file again. If the red x still appears, y ou may hav e to delete the image and then insert it again. Ph: +1 (919)-481 6895 www.adelser.com Page 1 TRIGGERING BOARDS FOR THYRISTORS ARCTI-CP The ARCTI-CP board enables to dispatch control pulses to 2 thyristors. A pulse transformer ensures the isolation between the power and the control and between the 2 outputs. Electrical Specifications The ARCTI-CP is normally tropicalised. Unless otherwise specified all data are given for 25°C. Pulse transformer Symbol n ∫U.dt Ts Imax LP CK RP RS UP UIS Parameters Transformation ratio Tension-time area Rise time to secondary Maximum peak current Inductance to primary Capacitance coupling Resistance of the primary winding Resistance of the secondary windings Dielectric test voltage Maximum operating voltage Ph: +1 (919) 481-6895 Min. www.adelser.com Typ. 1:1:1 1000 Max. Unit 1 2 5 190 0.4 0.4 3 380 µVs µs A mH pF Ω Ω kVAC VAC Page 2 TRIGGERING BOARDS FOR THYRISTORS Electrical Diagram gate 2-1 1-1 10R-2W 1-2 2-2 2-3 Cathode gate 10R-2W 1-3 1-4 2-4 Cathode Mechanical Specifications Nota : Connection with "FASTON" 6.3*0.8mm terminals. Transformer housing self-extinguishing (UL94 homologation), vacuum impregnation. Ph: +1 (919) 481-6895 www.adelser.com Page 3 TRIGGERING BOARDS FOR THYRISTORS ARCTI-CP2 The ARCTI-CP2 board enables to transmit control pulses to a high power thyristor. A pulse transformer insures the 14kV insulation between the power and the control command. The low leakage inductance of the transformer makes it possible to get a di/dt compatible with most of high power thyristors. Ph: +1 (919) 481-6895 www.adelser.com Page 4 TRIGGERING BOARDS FOR THYRISTORS Electrical specifications. On request the ARCTI-CP2 board can be adapted to the power supply and to the thyristor which has to be controlled. It can also be tropicalized. Unless otherwise specified all data are given for 25°C. Pulse Transformer Symbol n ∫U.dt Ts Imax LP CK SF RP RS UP UIS Parameters Transformation ratio Tension-time area Rise time to secondary Maximum peak current Primary inductance Coupling capacitance Leakage inductance Resistance of the primary winding Resistance of the secondary winding Dielectric test voltage Maximum operating voltage Min. 0.99 Typ. 1 7200 3 7 30 280 9 0.62 0.35 14 5 Max. Unit 1.008 µVs µs A 45 mH 300 pF 10 µH Ω Ω kVAC kVAC Electrical Diagram 1 SUPPLY 2 1 5 1 2 2 1 1 2 2 GATE 2 1 1 CONTROL 2 Ph: +1 (919) 481-6895 4 8 www.adelser.com CATHODE Page 5 TRIGGERING BOARDS FOR THYRISTORS Mechanical Specifications Nota : Connections with detachable terminal boards which include polarizing slot and locking device. (I=12 Amps, 5.08mm length of lay, approved by UL). Transformer housing self-extinguishing (UL94 approval), vacuum impregnation. Ph: +1 (919) 481-6895 www.adelser.com Page 6 TRIGGERING BOARDS FOR THYRISTORS ARCTI-CP3 The ARCTI-CP3 board enables to transmit control pulses to a high power thyristor. A pulse transformer insures the 4.5kV insulation between the power and the control command. The low leakage inductance of the transformer makes it possible to get a di/dt compatible with most of high power thyristors. Ph: +1 (919) 481-6895 www.adelser.com Page 7 TRIGGERING BOARDS FOR THYRISTORS Electrical Specifications If requested, the ARCTI-CP3 board can be adapted to the power supply and to the thyristor which has to be controlled. It can also be tropicalized. Pulse transformer Unless otherwise specified, all data are given for 25°C Symbol n ∫U.dt Ts Imax LP CK SF RP RS UP UIS Parameter Transformation ratio Tension-time area Rise time to secondary Maximum peak current Primary inductance Coupling capacitance Leakage inductance Resistance of the primary winding Resistance of the secondary winding Dielectric test voltage Maximum operating voltage Min. 0.99 Typ. 1 3500 1.8 8.5 12.5 375 6.5 0.250 0.170 4.5 1.5 1 2 Max. Unit 1.008 µVs µs A 13.5 mH 400 pF 7 µH 0.3 Ω 0.2 Ω kVAC kVAC Electrical Diagram 1 5 1 2 2 2 COMMANDE 2 1 11 1 GACHETTE 2 ALIM 2 1 Ph: +1 (919) 481-6895 4 8 www.adelser.com CATHODE Page 8 TRIGGERING BOARDS FOR THYRISTORS Mechanical Specifications Nota : Connections with detachable terminal boards which include polarizing slot and locking device. (I=12 Amps, 5.08mm length of lay, approved by UL). Self-extinguishing transformer housing (UL94 approval), vacuum impregnation. Ph: +1 (919) 481-6895 www.adelser.com Page 9 TRIGGERING BOARDS FOR THYRISTORS FART4 The FART4 module enables to trigger switch gates (2 head-to-foot thyristors) from a 0-10V or 020mA control command. Insulation : 3500Vac Input 0-10V and 0-20mA Detection of zero-crossing State display Standard housing Electrical specifications Unless otherwise specified all data are given for 25°C. General data Symbol TA TS VISO VINH Parameters Ambient operating temperature Storage temperature Insulation (Power / Control) (AC / 50Hz /1min) Starting inhibition voltage Min. 0 -40 Typ. Max. Unit 70 °C 125 °C 3.5 5 kV 20 V Power circuit Symbole VAC IGTmax F Parameters Operating voltage Maximum gate current Operating frequency Min. 48 Typ. 500 50 Max. Unit 400 VAC mA 60 Hz Control circuit Symbol VIN VIH VIL Parameters Input voltage Starting threshold of module Extinction threshold of module Ph: +1 (919) 481-6895 Min. 0 www.adelser.com Typ. 10 7.8 7 Max. Unit 15 VDC VDC VDC Page 10 TRIGGERING BOARDS FOR THYRISTORS General Diagram 2 V+ K1 5 G1 4 3 V- G2 1 ~ 6 K2 7 ~ Caution : do not operate the FART4 if one of the gates is disconnected. Mechanical Specifications Connections : 2.8*0.8mm "FASTON" terminals. Ph: +1 (919) 481-6895 www.adelser.com Page 11 TRIGGERING BOARDS FOR THYRISTORS CAUTION : ADELSER reserves the right to make modifications to its technical data and product specifications at any time without prior notice. These documents have no contractual value For more information: ADELSER, INC 2200 Gateway Centre Blvd Suite 213 Morrisville, NC 27560 +1 (919) 481-6895 Fax: +1 (919) 481-6910 Email:info@adelser.com NOTES Ph: +1 (919) 481-6895 www.adelser.com Page 12