VPK LED Parking Garage Vaportight Retrofit Product Information Project Name Type Catalog Number Date SPECIFICATIONS Features • Retrofit existing fluorescent vaportight luminaires with state-of-the-art low wattage high lumen LED. • Fast pace upgrade with little clean-up and no removal of existing fixture. • 1. Open lens and remove existing lamps, gear tray and clips 2. Install new clips and wire up the LED gear tray. 3. Install new lens and go! • Wide distribution works well in low mounting height applications. • To meet certifications ensure existing fixture matches dimensions shown. • Hose down & wet location fixture is IP67 rated (Sensored units are IP65 rated). • Frosted deep diffuser ensures visual comfort for drivers. • Very tough diffuser resists breakage and reduces replacement and maintenance costs. • LED light engine eliminates risk of glass breakage in parking garages. • Instant re-start, no warm-up times or reduced light output in cold environments. • Choice of two lumen packages and three dimming options available. • Long-life LEDs at L80 (80% lumen maintenance) at 60,000 hours reduce life cycle maintenance costs. • Available in 4’ and 8’ lengths. • Up to 99 lumens per watt. • Color Rendering Index (CRI) > 80. • Designed to retrofit existing SLP housing. • Made In USA. Meets ARRA & Buy American requirements. Construction Certifications • Conversion kit includes pre-wired LED engine assembly, white gear tray with retainer clips, frosted diffuser and polycarbonate latches • Deep diffuser is made with flame retardant 5VA (f1) fire rated materials • Certain airborne contaminants can diminish integrity of acrylic. Consult factory for chemical compatibility. • Stainless steel tamper resistant screws, order separately, (8) or (14) required. • Secure locking plastic latches standard • Weight: 1x4 - 6 lbs. 1x8 - 15 lbs. • • • • Please refer to the Lighting Facts website for specific product qualifications at www.lightingfacts.com. Application • • Electrical • • • • • • • • • • • UL 1598, 1598C & 8750 classified and cUL for Canada. Emergency-equipped fixtures labeled UL 924. Adheres to LM79, LM80 and TM21 industry standards. Input Voltage Range: 100/277 VAC Nom. (90-305 V Min/Max) Frequency: 50/60 Hz Nom. (47-63 Hz Min/Max) Active Power Factor Correction Power Factor: >0.90 @ full load, 100V through 277V Inrush Current: 60 Amps max @ 230 VAC, cold start 25ºC Harmonic Distortion: THD < 20% @ full load Protection: Over-Voltage, Over-Temperature (110º) & Short Circuit with self-recovery Compliant to FCC Part 15 requirements for EMI/RFI emissions NEC/CEC compliant ballast disconnect is standard Optional surge protection: ANSI Std. C62.41.2 Category A (10 kV) Optional emergency battery pack Suitable for use with most wired or wireless lighting control systems Suitable for wet locations: • Parking garages • Livestock buildings • Under awnings • Car washes • Low-bay Warranty • Five-year warranty. (Terms and Conditions Apply) CERTIFICATION IP65 IP66 IP67 CERTIFIED CERTIFIED CERTIFIED ORDERING INFORMATION – MODEL VPK LED Parking Garage Vaportight Retrofit – SIZE 1x4 1x4 Nominal 1x8 1x8 Nominal (non DLC) EXAMPLE VPK-1X4-LW-F-DFA-UL-40K – LUMEN OUTPUT LW Low HL High – DRIVER OUTPUT F Fixed DM 0-10v Dimming1 – SHIELDING DFA Deep Frosted Acrylic DCA Deep Clear Acrylic – DRIVER VOLTAGE UL Universal 120/277 VAC – COLOR TEMP 40K 4000 50K 5000 OTHER LSP Lighting Surge Protector (270 Joules) EB Emergency Battery Backup JP Job Pack ACCESSORIES (ORDER SEPARATELY) Stainless Steel Tamper Order Part: #95011778 (8 or 14 Required) Resistant Screws FOOTNOTES 1. Must be used in conjunction with lighting controls. Page 1/3 - Revised: 07/01/16 | Created: 2016 © 2016 Precision-Paragon [P2], a division of Hubbell Lighting, Inc. Because of continuing product improvement programs, Precision-Paragon [P2] reserves the right to change specifications without notice. Telephone [Midwest] 715.381.2971 / Website www.P-2.com VPK LED Parking Garage Vaportight Retrofit PHOTOMETRIC DATA PHOTOMETRIC DATA: VPK-1X4-LW-F-UL-40K All published luminaire photometric testing performed to IESNA LM-79-08 standards by a NVLAP certified lab. LUMINAIRE DATA Luminaire Ballast Ballast Factor Lamp Fixture Lumens Watts Mounting Shielding Angle Spacing Criterion Luminous Opening in feet Test: L04134339 Test Date: 04/17/13 INDOOR CANDELA PLOT ZONAL LUMEN SUMMARY 90 VPK-1X4-LW-F-UL-40K LED Parking Garage Vaportight Retrofit D310CQ50UNVA-A 1.00 LED 5052 51 Suspended & Ceiling N/A 0° = 1.22 90° = 1.20 Length: 4.29 Width: 0.54 Height: 0.29 70 60 819 AVG. LUMINANCE (Candela/Sq. M.) 50 1092 0 10 20 70 30 117 88 70 58 49 42 36 32 28 26 23 10 117 83 63 50 41 34 29 25 22 20 18 70 113 98 86 77 70 64 59 54 50 47 44 7 15 25 52 80 91 30 40 Average Luminance Angle RCR 50 117 95 79 68 59 52 46 42 38 34 32 %Fixt N.A. N.A. N.A. N.A. N.A. N.A. 546 80 70 117 101 90 81 73 67 61 57 53 49 46 %Lamp 332 734 1271 2624 4054 4588 80 COEFFICIENTS OF UTILIZATION (%) RC Lumens 0-20 0-30 0-40 0-60 0-80 0-90 273 0.0 _____ 40.0 _ _ _ _ 90.0 _ _ _ _ RW 0 1 2 3 4 5 6 7 8 9 10 Zone 50 113 91 77 66 57 50 45 40 37 33 31 50 30 113 86 68 56 47 41 35 31 28 25 23 10 113 80 62 49 40 33 29 25 22 19 17 50 106 85 71 61 53 47 42 38 34 32 29 30 106 80 64 53 45 39 34 30 27 24 22 0 10 106 76 59 47 38 32 28 24 21 19 17 0 91 65 50 40 32 27 23 20 17 15 14 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 0.0 22.5 45.0 67.5 90.0 881 875 862 841 812 775 731 679 621 558 492 425 368 302 236 331 150 104 881 876 865 849 828 803 772 736 695 652 607 561 521 475 429 377 320 258 881 880 877 876 875 871 869 866 860 851 842 829 815 793 762 712 641 541 881 882 888 900 914 935 957 977 995 1008 1017 1024 1027 1016 981 928 856 745 881 883 892 908 930 960 990 1018 1042 1060 1074 1087 1092 1076 1038 988 918 812 RCR = Room Cavity Ratio RC = Effective Ceiling Cavity Reflectance RW = Wall Reflectance OPERATING ENVIRONMENT Proposed System Min Temp Max Temp VPK-LW -30°C/-22°F 45°C/113°F VPK-HL -30°C/-22°F 35°C/95°F Application Notes 1. Application temperatures are provided to ensure the longevity and performance of the driver and LEDs. 2. Results are based off the In-Situ Temperature Measurement Test (ISTMT) along with the drivers' temperature and life curves. 3. Optional emergency battery equipped units have a minimum temperature of 10°C. 4. Precision-Paragon [P2]'s 5 year warranty assumes operation at the maximum ambient temperature range. LUMEN PACKAGE OPTIONS 4000K DETAILS* Proposed System Lumen Output CRI VPK-1X4-LW VPK-1X4-HL VPK-1X8-LW VPK-1X8-HL LW HL LW HL >80 >80 >80 >80 5000K DETAILS** CCT Lumens Per Fixture Input Watts Lumens Per Watt 4000K 4000K 4000K 4000K 5052 8322 10105 16643 51 90 102 181 99 92 99 92 CCT Lumens Per Fixture Input Watts Lumens Per Watt 5000K 5000K 5000K 5000K 5153 8488 10307 16976 52 92 104 185 99 92 99 92 *Lumen values shown are initial delivered lumens tested at 25°C per IES LM-79 standards. **Lumen values calculated with 1.02 multiplier based on LED manufacturer data. Page 2/3 - Revised: 07/01/16 | Created: 2016 © 2016 Precision-Paragon [P2], a division of Hubbell Lighting, Inc. Because of continuing product improvement programs, Precision-Paragon [P2] reserves the right to change specifications without notice. Telephone [Midwest] 715.381.2971 / Website www.P-2.com VPK LED Parking Garage Vaportight Retrofit FIXTURE DIMENSIONS *Drawings N.T.S. TAMPER RESISTANT LATCHES PLASTIC LATCHES: TAMPER RESISTANT SCREWS (ORDER SEPARATELY) PART #95011778 NOTES: *Torx screwdriver required for tamper resistant screws. *Screws Required: 1x4 = 8 or 1x8 = 14 *Images N.T.S. SCREW - #6 LENGTH - .62" Page 3/3 - Revised: 07/01/16 | Created: 2016 © 2016 Precision-Paragon [P2], a division of Hubbell Lighting, Inc. Because of continuing product improvement programs, Precision-Paragon [P2] reserves the right to change specifications without notice. Telephone [Midwest] 715.381.2971 / Website www.P-2.com