QOM-eLED Power Supply Installation Instructions Driver with no Dimming Module A LED DRIVER 1 (120 - 277V) A Output Load B C Output Load Output Load B C LED DRIVER 2 (120 - 277V) LED DRIVER 3 (120 - 277V) ABC NEU HOT GND Input Load *separate Inputs available; see next page. QOM-eLED Power Supply Installation Instructions Driver with no Dimming Module A LED DRIVER 1 (120 - 277V) A B B C LED DRIVER 2 (120 - 277V) LED DRIVER 3 (120 - 277V) C A Output Load Output Load Output Load B NEU HOT GND Input Load NEU HOT GND Input Load C NEU HOT GND Input Load QOM-eLED Power Supply Installation Instructions Driver with Dimming Module BL RD LED DRIVER 1 (120 - 277V) BL RD LED DRIVER 2 (120 - 277V) A 0 - 10V DIM-MOD 1 A B 0 - 10V DIM-MOD 2 B Output Load Output Load Output Load Dimmer control *separate 0-10v dim mods available; see next page. BL RD LED DRIVER 3 (120 - 277V) C 0 - 10V DIM-MOD 3 C NEU HOT GND Input Load * separate Inputs available; see next page. QOM-eLED Power Supply Installation Instructions Driver with Dimming Module BL RD LED DRIVER 1 (120 - 277V) BL RD LED DRIVER 2 (120 - 277V) A B 0 - 10V DIM-MOD 1 0 - 10V DIM-MOD 2 A BL LED DRIVER 3 (120 - 277V) RD C 0 - 10V DIM-MOD 3 B A C B A Output Load Dimmer control Output Load Dimmer control B NEU HOT GND Input Load NEU HOT GND Input Load C C Output Load Dimmer control NEU HOT GND Input Load QOM-eLED QOM-eLED 9.0” OUTPUT 12 VDC OUTPUT 24 VDC INPUT 100/277 V INPUT 100/277 V 0-10V DIM 0-10V DIM INPUT (A) FREQUENCY With Without LED DRIVER 1 (100 - 277V) LED DRIVER 2 (100 - 277V) LED DRIVER 3 (100 - 277V) INPUT (A) FREQUENCY With Without 60 60 0.60/0.29 50/60 100 100 0.95/0.40 50/60 120 120 1.20/0.58 50/60 200 200 1.90/0.80 50/60 180 180 1.80/0.87 50/60 300 300 2.85/1.20 50/60 A B C 0 - 10V DIM-MOD 1 0 - 10V DIM-MOD 2 0 - 10V DIM-MOD 3 14.5” A B C 12VDC 24VDC LED System Wire Size w 10 AWG (5.6mm2) 12 AWG (3.3mm2) 12 25 60 17 25 40 80 100 500 240 100 706 480 192 92 38 271 185 115 58 46 300 150 120 14 AWG (2.0mm2) 16 AWG (1.3mm2) 119 57 24 168 114 71 36 29 18 AWG 20 AWG (0.78mm2) (0.50mm2) 76 36 15 107 73 45 23 18 48 23 10 67 46 29 14 11 22 AWG (0.33mm2) 24 AWG (0.2mm2) 30 14 6 42 29 18 9 18 9 4 26 18 11 5 11 6 2 16 11 7 3 7 4 3 26 AWG (0.13mm2) Output Load 2 141 59 415 282 176 88 71 NEU HOT GND Input Load Output Load Output Load Dimmer control SECONDARY PRIMARY 14.5” This product must be installed in accordance with the applicable installation code by a person familiar with the construction and operation of the product and the hazards involved. UL Class 2 7310_S-000 E220165 3426-32 Dimmer, If use, Must be Electronic Low Voltage Dimmer Electrical Specifications 4.25” Max Output Output Voltage Output Current OperatingTemp. Input Current power (W) (V) (A) range ( F) (A) 60 100 12 24 9.0” 5.0 4.1 -40 ~140 F Features Limited output voltage and current, plus isolation for safe operation Dimmable w/ additional 0-10V Dimming Module Fully potted for moisture resistance and thermal Wet Listed Class 2 CSA Listed LED Power Supply (CSA 2108, 1838 ) 5 year warranty and Average 90% Efficiency 5.0 4.1 Max Input power (W) Weight (lbs) IP Rating 60 100 0.3/135 IP 66 Each 12V QOM-ELED unit up to 1-3 60w or 1-3 100w. Each 24V QOM-ELED unit has one to three 100W (200W,300W) Drivers. Primary Voltage - Universal Secondary Voltage 12 / 24VDC © 2015, Q-Tran Inc. 155 Hill St. Milford, CT 06460. All rights reserved - P: 203-367-8777 - F: 203-367-8771 - E: sales@q-tran.com - www.q-tran.com QOM-eLED Design Guide & Installation Instructions * To order additional lengths of wire for connection in the secondary Please call Factory for availability. Risk of Electric Shock. Install power unit 5 feet (1.5 m) or more from a pool or spa and 10 feet (3.05 m) or more from a fountain when the power unit is conduit-connected.Where the power unit is installed within 10 feet (3.05 m) of a pool or spa, connect power unit to a GFCI protected branch circuit. Risk of Electric Shock. Install power unit 5 feet (1.5 m) or more from a pool, spa, or fountain when the power unit is power-supply cord connected. Where the power unit is installed (a) indoors within 10 feet (3.0 m) of a pool, spa, or fountain or (b) outdoors, connect power unit to a receptacle protected by a GFCI. Do not use an extension cord when the power unit is cordconnected. Outdoor power units should be connected to a GFCI protected flush type cover plate receptaclemarked "Wet Location" while in use. Mounting Hole hru od T R Hole ” 1/4 Thru Rod 3/8” ” 1.57 ” 1.77 ” 3.32 ” 3.12 Surface Wall Mount Pole Mount Note : The main secondary wiring is intended for shallow burial - less than 6 inches (152mm) - unless wiring provided is intended for direct burial. © 2015, Q-Tran Inc. 155 Hill St. Milford, CT 06460. All rights reserved - P: 203-367-8777 - F: 203-367-8771 - E: sales@q-tran.com - www.q-tran.com