Motor Controllers AC Semiconductor Motor Controller Type RSDR • Soft starting, soft stopping of 3-phase induction motors • 2 Phase controlled with internal bypass relays • Rated operational voltage: 230-460VAC 3-phase • Rated operational current: up to 500A (280kW) AC-53b • Auxiliary relay outputs (2x NO) • Overcurrent "shearpin" protection (RSDR40230B - RSDR40500B) • Ramp-up and Ramp-down time settings up to 30sec • IP20 Up to 55kW • UL approved up to RSDR40280B Product Description Ordering Key RSDR is a 2-phase controlled, internally bypassed soft starter for 3-phase induction motors. Initial torque, rampup and ramp-down parame- D-Line Motor Controller Rotary Selector Rated operational voltage Rated operational current Control voltage ters can be selected via rotary knobs. Two Normally Open (NO) auxiliary relay contacts are also available for Run and Ready/Fault indication. RSD R 40 280 B Type Selection Type Rated operational voltage Ue Rated operational Current Ie RSDR 40: (230-460VACrms) 55: 55 AACrms 66: 66 AACrms 80: 80 AACrms 97: 97 AACrms 132: 132 AACrms 160: 160 AACrms Control voltage Uc 195: 195AACrms 230: 230AACrms 280: 280AACrms 350: 350AACrms1 430: 430AACrms1 500: 500AACrms1 B: 24VDC/ 110VAC* * externally supplied Selection Guide Rated operational voltage Ue Control voltage Uc Rated operational current Ie 230 - 460 VACrms (-15%, + 10%) 50/60Hz (+/- 2Hz) 24VDC/ 110VAC 55A AC-53b RSDR40055B 66A AC-53b RSDR40066B 80A AC-53b RSDR40080B 97A AC-53b RSDR40097B 132A AC-53b RSDR40132B 160A AC-53b RSDR40160B 195A AC-53b RSDR40195B 230A AC-53b RSDR40230B 280A AC-53b RSDR40280B 350A AC-53b RSDR40350B1 430A AC53-b RSDR40430B1 500A AC-53b RSDR40500B1 1 Not UL approved Specifications are subject to change without notice (26.01.2011) 1 RSDR Environmental Specifications Ambient temperature Storage temperature Relative Humidity 0ºC to 40ºC (32ºF to 104ºF) Above 40ºC de-rate linearly by 2% of unit FLC per ºC to a derate of 40% at 60ºC. -25ºC to +60ºC -13ºF to 140ºF <85% non-condensing, not exceeding 50% @ 40ºC Degree of Protection Installation altitude Pollution Degree IP20 up to 55kW IP00 - 75kW to 280kW 1000m. Above 1000m de-rate linearly by 1% of unit altitude of 2000m 2 (For use in Pollution degree 2 environment) General Specifications Output Specifications Ramp up time Ramp down time Initial torque Operational voltage (Ue) Rated frequency Rated insulation voltage(Ui) Form designation Status indication LEDs Power supply ON Alarm Tripped and Reset Control voltage (Uc) A1-A2: Rated impulse withstand voltage (Uimp) IEC rated operational current Ie (AC53b) Overload cycle according to EN/IEC 60947-4-2 Auxiliary relay outputs Run relay (13, 14) 1...30s 0...30s 30% ... 100% 230 - 460 VACrms (-15% +10%) 50 - 60Hz (+/- 2Hz) 500V Form 1 Ready (23, 24) LED, Green (continuous) LED, Red (flashing) LED, Orange (flashing) 24VDC/110VAC 55/66/80/97/132/160 195/230/280/350/430/500A AC53b: 3-5:355 (10starts/hour) 230VAC 3AAC Normally Open (NO) 230VAC 3AAC Normally Open (NO) 4kV External Supply Specifications External supply voltage (X1, X2) Residual ripple Spikes/ switching peaks Turn On/ Off response Overvoltage protection 24VDC (4VA approx. per starter) RSDR40055B up to RSDR40195B 24VDC (12VA approx per starter)* RSDR40230B up to RSDR40500B 100 mV 240 mV No overshoot of V out Output voltage must be clamped to < 30V * Power supply must be capable of 4Amps for 250ms Refer to Accessories Section in the datasheet for recommended power supplies. 2 Specifications are subject to change without notice (26.01.2011) RSDR Motor Ratings - In Line Assigned motor kW rating @ 400V UL rating HP @ 460V RSDR40055B 30kW 40HP RSDR40066B 37kW 50HP RSDR40080B 45kW 60HP RSDR40097B 55kW 75HP RSDR40132B 75kW 100HP RSDR40160B 90kW 125HP RSDR40195B 110kW 150HP RSDR40230B 132kW 150HP RSDR40280B 160kW 200HP RSDR40350B1 200kW 250HP RSDR40430B1 250kW 350HP RSDR40500B1 280kW 400HP Conductor Data Line conductors: 1L1, 3L2, 5L3, PE /2T1, 4T2, 6T3 according to IEC60947 UL rated data Terminal screws Tightening torque Stripping length RSDR40055B RSDR40066B RSDR40080B RSDR40097B RSDR40132B RSDR40160B RSDR40195B RSDR40230B RSDR40280B RSDR40350B1 RSDR40430B1 RSDR40500B1 6…16mm2 AWG 8…4 0.8 x 4 mm 2Nm (18 lb.in) 13mm 16…35mm2 AWG 6…1 1.2 x 6.5 mm 2.5Nm (27 lb.in) 17mm 50…95mm2* 2x 95mm2** AWG 2x 2/0 7xM10 14Nm (123.9 lb.in) - 2x150mm2 AWG 1/0…250 Kcmil 7xM8 12Nm (106.2 lb.in) - AWG 2x 350 Kcmil 7xM10 14Nm (123.9 lb.in) - * Kit installation with insultation KIT part number MIS854_CG is required for UL compliance. ** Kit installation with insulation KIT part number MIS855_CG is required for UL compliance. RSDR40…. Secondary conductors: X1, X2, 13, 14 A1, A2, 23, 24 according to IEC60947 UL rated data Terminal screws Tightening torque Stripping length 1 1 x 0.75 ... 2.5mm2 2 x 0.75 ... 1.0mm2 AWG 18…12 0.5 x 3.5 mm 0.8Nm 1x 6mm 2x 11mm Not UL approved Specifications are subject to change without notice (26.01.2011) 3 RSDR Dimensions 0[ (DUWK VWXG 0[ (DUWK VWXG $0 '51 RSDR40066B RSDR40080B RSDR40097B 81/(66 27+( ',0(16,216 685)$&( ),1 72/(5$1&(6 /,1($5 $1*8/$5 &+ )( 3DUW 1 RSDR40055B '5$:1 &+. ' 0[ (DUWK VWXG '5$:1 &+. ' 4 81/(66 27+(5:,6 ',0(16,216 $5( 685)$&( ),1,6+ 72/(5$1&(6 /,1($5 $1*8/$5 Not UL approved RSDR40132B RSDR40160B RSDR40195B 1 0 [ 6(7 6&5(: 0[ (DUWK VWXG 0[ +(; +($' 6(76&5(: %=3 1$ RSDR40230B RSDR40280B RSDR40350B1 RSDR40430B1 RSDR40500B1 81/(66 27+(5:,6( ',0(16,216 $5( ,1 685)$&( ),1,6+ 72/(5$1&(6 /,1($5 $1*8/$5 1$0 '5$:1 &+. ' $339 ' 0)* All dimensions in mm Specifications are subject to change without notice (26.01.2011) RSDR Short circuit protection Model Name 400/ 460V Range Class 5 (Standard Rating) 3 X FLC for 5 seconds 10 starts per Hr Class 10B 3.5 x FLC for 12 seconds 10 starts per Hr Siba semiconductor fuse for type 1 coordination Short Circuit Protection RSDR40055B Ie (Arms) 55A Motor kW @ 400V 30kW Ie (Arms) 41A Motor kW @ 400V 22kW RSDR40066B 66A 37kW 55A 30kW RSDR40080B 80A 45kW 66A 37kW RSDR40097B 97A 55kW 66A 37kW RSDR40132B 132A 75kW 97A 55kW 2061032.250A RSDR40160B 160A 90kW 116A 60kW 2061032.400A RSDR40195B 195A 110kW 160A 90kW Model Name 400/ 460V Range Class 10A @40˚C 3 X FLC for 12 seconds 3 starts per Hr RSDR40230B RSDR40280B RSDR40350B RSDR40430B RSDR40500B Ie (Arms) Motor kW @ 400V 230A 280A 350A 430A 500A 132kW 160kW 200kW 250kW 280kW 2018920.125A 2061032.200A Siba semiconductor Fuse for Type 1 Coordination Short Circuit Protection Rated Short Circuit current (lq) 2062032.630 18kA 18kA 18kA 18kA 18kA 2063032.1000 UL ratings and protection requirements Maximum surrounding air temperatures Model 480v rated RSDR40055B RSDR40066B RSDR40080B RSDR40097B Maximum 40˚C Power Input Current Power 66 A 50hp 60 A 40hp 55 A 40hp 80 A 100hp RSDR40195B 195 A 150hp RSDR40280B 160 A 241 A 280 A 30hp 72 A 75hp 132 A RSDR40230B 45 A 60hp 97 A RSDR40132B RSDR40160B Maximum 50˚C Input Current 50hp 78 A 60hp 119 A 75hp 125hp 144 A 100hp 200hp 193 A 150hp 176 A 200hp 125hp 224 A 150hp Short Circuit Protection Suitable for use on a circuit capable of delivering not more than the rms symmetrical amperes indicated below, 480 volts maximum, when protected by fuses or inverse-time circuit breakers, rated maximum amperes as indicated below: Model RSDR40055B Short circuit rating 5 kA RK5 time delay fuse rated 600VAC Circuit breaker rated 600VAC - 80 A RSDR40066B 10 kA 125 A RSDR40097B 10 kA 200 A RSDR40080B RSDR40132B RSDR40160B RSDR40195B RSDR40230B RSDR40280B 10 kA 10 kA 10 kA 10 kA 18 kA 18 kA Specifications are subject to change without notice (26.01.2011) 175 A - 250 A 350 A 400 A 500 A 350 A 450 A 450 A 450 A - 5 RSDR X1 X2 A1 A2 Control supply 24VDC 0 +24V Start/Stop 24VDC/110VAC Connection Diagram 3 Amp NO AC11 230VAC 13 14 23 24 Alarms No. of Flashes Red LED Green LED 2 ON 1 3 4 5* 6* Rapid flashes* Red LED not Flashing Orange LED Flashing ON SCR/Supply Fault ON Control voltage <24V ON ON ON ON OFF Flashing Fault Description Over-temperature Bypass Relay Failure Shearpin (Load current > 4.5x Ie) Overload - refer to chart above Overcurrent Fault Tripped and Reset, Ready for next start * Only available on RSDR models RSDR40230B to RSDR40500B 6 Specifications are subject to change without notice (26.01.2011) RSDR Standards Approvals CE Marking UL*, UL508 Inustrial Control Equipment EMC/LVD Radiated Radio Frequency Immunity IEC/EN 61000-4-3 10V/m, 80 - 1000 Mhz IEC/EN 60947-4-2 Electrostatic Discharge (ESD) Immunity IEC/EN 61000-4-2 8kV, Air discharge IEC/EN 61000-4-6 140dbµV, 0.15 - 80 MHz 4kV, Contact Radio Interference field emission (radiated) IEC/EN 55011, Class A IEC/EN 61000-4-4 Radio Interference voltage emission (conducted) IEC/EN 55011, Class A Electrical Fast Transient Burst Immunity Conducted Radio Frequency Immunity Output, 2kV Input, 1kV Electrical Surge Immunity Input, line to line 1kV Input, line to earth 2kV * Applicable to RSDR40055B up to RSDR40280B units Terminal Diagram PE 1L1 3L2 5L3 PE 1L1 3L2 5L3 RSDR AC MOTOR CONTROLLER INIT. TORQUE RSDR AC MOTOR CONTROLLER 80% 50% 30% INIT. TORQUE 100% 50% 30% 80% 100% 20 10 RAMP DOWN 0 RAMP UP 30 sec. 10 No. of Flashes (Red LED) Fault Description 10 RAMP UP 10 0 SCR/Supply Fault Over-temperature Control Voltage < 24V Bypass Relay Failure 1 2 3 4 20 RAMP DOWN No. of Flashes (Red LED) 20 20 Fault Description SCR/Supply Fault Over-temperature Control Voltage < 24V Bypass Relay Failure 1 2 3 4 30 sec. 30 sec. 30 sec. 2T1 4T2 6T3 2T1 4T2 6T3 RSDR40066B / RSDR40080B / RSDR40097B RSDR40055B 1L1 PE 3L2 1L1 PE 3L2 5L3 5L3 RSDR AC MOTOR CONTROLLER RSDR AC MOTOR CONTROLLER INIT. TORQUE 50% 30% RAMP DOWN 10 RAMP UP 10 0 80% 100% 20 30 sec. 20 No. of Flashes (Red LED) 1 2 3 4 Fault Description SCR/Supply Fault Over-temperature Control Voltage < 24V Bypass Relay Failure INIT. TORQUE 50% 30% 80% 100% 30 sec. RAMP DOWN 10 0 RAMP UP 10 20 30 sec 20 No. of Flashes (Red LED) Fault Description 1 2 3 4 5 6 Rapid Flashing SCR/Supply Fault Over-temperature Control Voltage < 24V Bypass Relay Failure Shearpin (I> 4.5Ie) Overload Overcurrent 30 sec 2T1 4T2 6T3 RSDR40132B / RSDR40160B / RSDR40195B 2T1 4T2 6T3 RSDR40230B / RSDR40280B / RSDR40350B1 RSDR40430B / RSDR40500B1 1. Not UL approved Specifications are subject to change without notice (26.01.2011) 7 RSDR Wiring Diagrams Soft starter connection using mains contactor L1 L2 L3 PE +24VDC or 110VAC + 24VDC 0 VDC Z1 K1M Z1 X2 X1 S1 PFC 1L1 3L2 5L3 F1 K2.1 S2 K2.2 13 RSDR 14 M1 run ready /fault start/stop M 3~ A1 RSDR A2 A1 K2 A2 X1 X2 A1 A2 13 14 23 24 - + 24VDC <100m 2T1 4T2 6T3 RSDR 0VDC or N A1 K1M A2 K1M - Mains contactor Z1 - Overload relay F1 - Semiconductor fuse for type 1 coordination M1 - Load (3-phase motor) Delta Connection of RSDR RSDR 2T1 4T2 6T3 2T1 4T2 6T3 W2 W1 V1 U1 M 3~ RSDR V2 U2 Delta connection at Motor W2 W1 V1 U1 M 3~ V2 U2 Delta connection at RSDR RSDR series offers the possibility of connecting the softstarter in the delta as shown above. Delta connection can be made either at the motor side or at the soft starter (RSDR) side. Where several conductors are to be connected, the difference between the wires/cables used must not exceed one DIN Standard size level. 8 Specifications are subject to change without notice (26.01.2011) RSDR Application Guide (for Determination of appropriate Trip Class) Application Trip class Start time (sec.) 5 5 5 5 10 5 5 5 5 10 Star/Delta applications with < 5sec Star time. Motor starting off load. Starting of unloaded conveyor Dedicated circuits ensure motor starts unloaded Mixer starting with no material in basin Generally easy to start when pumping water 10 10 10 10B 20 20 12 12 23 12 12 12 Can be difficult to start Certain compressor systems can be hard to start Starting of fans > 45kW Suitable for star/Delta applications with, 12sec Star time Application requires more starting torque than Star/ Delta Starting of load mixer Standard start Unloaded conveyor Unloaded compressor Unloaded mixer Centrifugal pump Positive displacement pump Loaded compressor High inertia fan Heavy start High torque Heavy mixer Notes Application Guide (based on Application Trip Class) Ie (Amp) @ 400V In Line kW @ 400V Trip Class 5 3-5: 355 10 starts/hr Trip Class 10B 3.5-12: 708 5 starts/hr Trip Class 10 3-23: 697 5 starts/hr Trip Class 20 4-19: 701 5 starts/hr Trip Class 30 4-29: 691 5 starts/hr 55A 30kW RSDR40055B RSDR40066B RSDR40066B RSDR40097B RSDR40132B 66A 37kW RSDR40066B RSDR40080B RSDR40080B RSDR40132B RSDR40132B 80A 45kW RSDR40080B RSDR40132B RSDR40132B RSDR40132B RSDR40160B 97A 55kW RSDR40097B RSDR40132B RSDR40132B RSDR40160B RSDR40195B 132A 75kW RSDR40132B RSDR40195B RSDR40195B RSDR40230B * RSDR40280B * 160A 90kW RSDR40160B RSDR40230B * RSDR40230B * RSDR40230B * RSDR40280B * 195A 110kW RSDR40195B RSDR40230B * RSDR40230B * RSDR40280B * RSDR40430B *1 1 230A 132kW RSDR40230B RSDR40280B * RSDR40350B * RSDR40430B *1 RSDR40500B *1 280A 160kW RSDR40280B RSDR40350B *1 RSDR40430B *1 RSDR40500B *1 Note 1 1 1 350A 200kW RSDR40350B RSDR40500B * RSDR40500B * Note Note 1 430A 250kW RSDR40430B Note Note Note Note The above trip curves can be used as a guidance to identify the required unit for the application duty. Subsequent restarts, following an overload trip, can be 1 500A 280kW RSDR40500B Note Note Note restricted due to a cooling time. The severity of the overload determines the cooling time which has a maximum value ofNote 10 minutes. Note: Contact Carlo Gavazzi representative *. Trip class rating of 3 starts/hr 1. Not UL approved Specifications are subject to change without notice (26.01.2011) 9 RSDR Application Guide (cont.) 100 90 80 70 60 50 40 S e c onds to T rip 30 40°C 3 start/Hr 20 10 9 8 7 6 5 4 3 2 Model RSDR40230B RSDR40280B RSDR40350B RSDR40430B RSDR40500B 1 rated current 230A 280A 350A 430A 500A 1.1 1.5 2 2.5 3 253 308 385 473 550 345 420 525 645 750 460 560 700 860 1000 575 700 875 1075 1250 690 840 1050 1290 1500 3.5 805 980 1225 1505 1750 4 920 1120 1400 1720 2000 4.5 x Ie 1035 1260 1575 1935 2250 Trip Level Current (Amps) The above trip curves can be used as a guidance to identify the required unit for the application duty. Subsequent restarts, following an overload trip, can be restricted due to a cooling time. The severity of the overload determines the cooling time which has a maximum value of 10 minutes. 10 Specifications are subject to change without notice (26.01.2011) RSDR Wiring Diagrams (cont.) Soft starter connection using semiconductor contactor L1 L2 L3 PE +24VDC or 110VAC U> Q1 + 24VDC I> PFC I> I> Z1 F1 S1 RSDR M1 A1 ready /fault run start/stop M 3~ X1 X2 A1 A2 13 14 23 24 - + 24VDC 2T1 4T2 6T3 <100m RSDR X1 0 1 1L1 3L2 5L3 Z1 0 VDC X2 0VDC or N A2 RSDR Q1 - Cable protection Z1 - Overload relay F1 - Semiconductor fuse for type 2 coordination, in addition to Q1 RSDR - Soft starter - Emergency Stop 1 - Undervoltage release with early-make auxiliary contact Timing Diagram Specifications are subject to change without notice (26.01.2011) 11 RSDR Accessories - External Power Supply 24VDC For RSDR40055B to RSDR40195B, an external control supply with 24VDC, 5W output needs to be provided to terminals X1-X2. The following power supplies can be used:- SPD24101 Input Voltage Output Power Terminal Type SPD24101B 90-265VAC 120-370VDC 10W Screw terminal Input Voltage Output Power Terminal Type 90-265VAC 120-370VDC 10W Spring terminal For RSDR40230B to RSDR40500B, a power supply capable of supplying 4Amps for 250ms is required across terminals X1X2. The following power supply can be used:- SPD241001 Input Voltage Output Power Terminal Type 12 90-264VAC 120-375VDC 100W Screw terminal Specifications are subject to change without notice (26.01.2011)