pr ouddi s t r i but or of Vi s i tour www. yout ube. com/us er /ebhor s man ShopOnl i ne ebhor s man. com Neo-Ray luminaires feature a distinctive combination of high quality and contemporary aesthetics. Our specification-grade luminaires transform architectural spaces into dynamic environments. 9-1 Cooper Lighting by Eaton | Product Selection Guide | Sixth Edition | www.cooperlighting.com Neo-Ray With an unmatched attention to detail, Neo-Ray offers direct, indirect and direct-indirect luminaires, including the innovative Straight & Narrow series with the option of lenses or snap-in louvers. Neo-Ray's thin profile series of architectural fluorescent and LED luminaires offers a wide selection of edge-lit textures and colored light diffusers. SEE PAGE 9-101 FOR NEW PRODUCTS. Bank of America, Trading Floor, New York, NY I Photography: Paúl Rivera Cooper Lighting by Eaton | Product Selection Guide | Sixth Edition | www.cooperlighting.com 9-2 TABLE OF CONTENTS STRAIGHT & NARROW 22DR LED Straight & Narrow Page 9-5 22DR Straight & Narrow Page 9-6 23DR Straight & Narrow Page 9-7 23XR Wall Wash Straight & Narrow Page 9-8 22DP LED Straight & Narrow Page 9-9 22DP Straight & Narrow Page 9-10 22DIP Straight & Narrow Page 9-11 23DP Straight & Narrow Page 9-12 23DIP Straight & Narrow Page 9-13 22DW LED Straight & Narrow Page 9-14 22DW Straight & Narrow Page 9-15 22DIW Straight & Narrow Page 9-16 23DW Straight & Narrow Page 9-17 23ADIW, 23DIW Straight & Narrow Page 9-18 22DS LED Straight & Narrow Page 9-19 22DS Straight & Narrow Page 9-20 7-A Page 9-23 41 Page 9-24 42 Page 9-25 73 Page 9-26 77 Page 9-27 81 Page 9-28 RECESSED LINEAR 23DS Straight & Narrow Page 9-21 Versys 1B Page 9-22 NEO-RAY RECESSED 82 Page 9-29 Symbio 294 Page 9-30 Symbio 292 Page 9-31 Symbio 194 Page 9-32 Luminous HE 282, 284 Page 9-33 Fenestra 272, 274 Page 9-34 Fenestra 262, 264 Page 9-35 Fenestra 252, 254 Page 9-36 Fenestra 242, 244 Page 9-37 Fenestra 232 ISL, 234 ISL Page 9-38 Fenestra 232, 234 Page 9-39 Fenestra 222, 224 Page 9-40 Fenestra 202, 204 Page 9-41 Fenestra 174 Page 9-42 Fenestra 154 Page 9-43 Fenestra 142, 144 Page 9-44 VIDEO CONFERENCE PERIMETER Series 7-VCR Page 9-47 79-PF Page 9-48 79-OS Page 9-49 78 Page 9-50 76-PF Page 9-51 75 Page 9-52 Fenestra 112, 114 Page 9-45 Series 7 Page 9-46 SEE PAGE 9-101 FOR NEW PRODUCTS. 9-3 Cooper Lighting by Eaton | Product Selection Guide | Sixth Edition | www.cooperlighting.com COVE SUSPENDED ARCHITECTURAL 72 Page 9-53 71 Page 9-54 70 Page 9-55 Al-Cove 74-IW Page 9-56 74-IC Page 9-57 Panelit 52 DIP Page 9-58 Nuage 301-IP Page 9-59 Nuage 301-IP, 301-DL Page 9-60 Petite Nuage 302-IP, 302-DIP Page 9-61 Viceroy 501-IP Page 9-62 Nimbus I 601-IP Page 9-63 Twin Beam 611-IP Page 9-64 Nimbus II 701-IP Page 9-65 Shell II 201-IP 9-66 Triad 17-IP Page 9-67 Europa 16-DIP, 16-IP Page 9-68 SUSPENDED ROUNDS SUSPENDED GEOMETRIC 2S-DP Page 9-69 Geo 14-DIP Page 9-70 TABLE OF CONTENTS PERIMETER (CONTINUED) Geo 44-DP Page 9-71 Omni 66-DIP Page 9-72 Geo 80-IP Page 9-73 Geo 83-DP Page 9-74 Geo 89-DIP Page 9-75 Cirque 4-AIP, 4-ADP, 4-IP, 4-DP Page 9-76 Cirque 6-AIW, 6-ADW Page 9-80 Cirque 6-DIW Page 9-81 Geo 14-DIW Page 9-82 Europa 16-DIW Page 9-83 Europa 16-IW Page 9-84 WALL MOUNT Cirque 6-AIP, 6-ADP, 6-IP, 6-DP Page 9-77 Cirque 6-DIP Page 9-78 Cirque 4-AIW, 4-ADW Page 9-79 SEE PAGE 19-65 FOR NEW PRODUCTS. Triad 17-IW Page 9-85 Omni 66-DIW Page 9-86 Geo 80-IW Page 9-87 Geo 83-DW Page 9-88 Geo 89-DIW Page 9-89 Shell II 201-IW Page 9-90 Nuage 301-IW Page 9-91 Petite Nuage 302-DIW Page 9-92 Geo 44-DS Page 9-98 Omni 66-DS Page 9-99 Geo 83-DS Page 9-100 SURFACE Nimbus I 601-IW Page 9-94 Twin Beam 611-IW Page 9-95 Nimbus II 701-IW Page 9-96 2S-DS Page 9-97 SEE PAGE 9-101 FOR NEW PRODUCTS. Cooper Lighting by Eaton | Product Selection Guide | Sixth Edition | www.cooperlighting.com 9-4 NEO-RAY Viceroy 501-IW Page 9-93 STRAIGHT & NARROW DIRECT FEATURES r Extruded aluminum housing in 2', 3', 4', 6' or 8' illuminated sections r Trimless, high-transmission, lay-in diffuser r 120-277 voltage electronic driver certified to UL and CUL standards r Durable, low-gloss, white, powder-coated acrylic finish r Individual fixtures or run configurations r Two LED light levels r Three LED color temperatures Support wire (by others) 2-3/8" Compliances may not apply to all product configurations. Please consult the product spec sheet for compliance details. COMPLIANCES: UL/cUL Listed - Damp Location, ARRA Compliant, LM79 - LM80 Compliant, NYC Code Compliant 4" 22DR LED STRAIGHT & NARROW 3" S22DR LED (ETG) ORDERING INFORMATIONΔ SAMPLE NUMBER: 22DR-1-L35-ETG-6 -U-DD-S92HT Series Light Distribution Mounting Light Level (Values Reflect 3500K, 4' Fixture) Lamp Type Ceiling Type Length Voltage 22=Straight & Narrow D=Direct R=Recessed 1=Level 1, 2100 Lumens, 33 Watts 2=Level 2, 2700 Lumens, 45 Watts L30=LED, 3000K L35=LED, 3500K L40=LED, 4000K ETG=15/16" Exposed T-grid FSR=Sheetrock® (Trimless) FTG=9/16" Exposed T-grid SR=Sheetrock® (Flanged) STG=Slot T-grid 2=2' 3=3' 4=4' 6=6' 8=8' xx=Continuous Run 1=120V 2=277V U=Universal (120-277V) Driver 1 Shielding Options DD=Dimming Driver ED=Electronic Driver S92HT=High Transmission Lens NOTES: Δ Level 1 is not available in universal voltage for some fixture lengths. Please consult factory. Δ Acrylic lenses will be slightly shorter than housing length at ambient temperature in order to compensate for normal thermal expansion during operation. 1. Required voltage information. MOUNTING INFORMATION Individual 5" Access plate 5" 5" Access plate Access plate Continuous 5" Access plate BOR Fixture 23-3/8" 2' Individual 5" 35-3/8" 3' Individual Access plate 5" INT Fixture 71-3/8" 6' Individual Access plate 71-11/16" 6' BOR 95-11/16" 8' BOR 48" 4' INT 72" 6' INT 96" 8' INT EOR Fixture 35-11/16" 3' EOR 47-11/16" 4' EOR 71-11/16" 6' EOR 95-11/16" 8' EOR 95-3/8" 8' Individual ETG (15/16" Exposed T-Grid) Mounting details 3-1/4" Grid center to center FTG (9/16" Fine T-Grid) Mounting details 3" Grid center to center STG (9/16" Slot T-Grid) Mounting details 3" Grid center to center SR (Sheetrock) Mounting details 2-5/8" Rough in wide opening FSR (Flangeless Sheetrock) Mounting details 2-7/8" Rough in wide opening NEO-RAY 47-3/8" 4' Individual Specifications and dimensions subject to change without notice. Consult your Cooper Lighting Representative or visit www.cooperlighting.com for available options, accessories and ordering information. 9-5 Cooper Lighting by Eaton | Product Selection Guide | Sixth Edition | www.cooperlighting.com 3/16" End plate Support wire (by others) 2-3/8" Compliances may not apply to all product configurations. Please consult the product spec sheet for compliance details. COMPLIANCES: UL/cUL Listed - Damp Location, ARRA Compliant, NYC Code Compliant 4" STRAIGHT & NARROW DIRECT FEATURES rDirect light distribution recessed luminaire rFully extruded aluminum housing offers precision and enhanced rigidity r Staggered lamping minimizes socket shadow in a 2" aperture rFlush and regressed lay in lens provides clean look and easy upkeep rSnap-in louver design for easy installation and better retention r Incremental lengths of 3', 4', 6' and 8' rIndividual fixtures and run configurations to the nearest foot 22DR STRAIGHT & NARROW 3" S22DR/1T5 ETG with lens ORDERING INFORMATIONΔ SAMPLE NUMBER: 22DR-1T5-ETG-4D-UEB-S92 Series Light Distribution Mounting Number of Lamps (Not Included) Lamp Type Ceiling Type Length Voltage Ballast 1 22=Straight & Narrow D=Direct R=Recessed 1=1 Lamp T5=T5 T5HO=T5HO ETG=15/16" Exposed T-grid FSR=Sheetrock® (Flangeless) FTG=9/16" Exposed T-grid SR=Sheetrock® (Flanged) STG=Slot T-grid 3=3' 4=4' 6=6' 8=8' xx=Continuous Runs 1=120V 2=277V U=Universal (120-277V) DB=Dimming Ballast EB=Electronic Ballast (Standard) Electronic Dimming Balast Options 1 Emergency 1 Fusing Shielding Options 1=Lutron® 3 Wire Line Voltage 1% Dimming 2=Lutron® 3 Wire Line Voltage 10% Dimming 3=Lutron EcoSystem® Bus 1% Dimming 4=Lutron EcoSystem® Bus 10% Dimming 5=0-10 Volt Dimming 6=Hot & Neutral Line Voltage Dimming 7=0-10 Volt 2 Step Dimming EC=Emergency Circuit EM=Emergency Pack (Consult Factory) GLR=GLR GMF=GMF S22R=Satin White Regress Lens 2 S91=High Performance Louver S91P=High Performance Louver with Acrylic Overlay S91W=White Painted Louver S91WP=White Painted Louver with Acrylic Overlay S92=Satin White Lens S92HT=High Transmission Lens NOTES: Δ For some electronic, dimming and EM battery pack ballast combinations, fixture has space limitation (consult factory). Δ Standard EM Pack is for 1 lamp. Δ For dimming, specify ballast option. Δ Acrylic lenses will be slightly shorter than housing length at ambient temperature in order to compensate for normal thermal expansion during operation. Δ Due to various constraints, some options may not be combined with others. Please consult your Cooper Lighting Representative for additional information. 1. Required voltage information. Maximum ballast width=1.18". 2. Regress lens not available with T5HO lamping. MOUNTING INFORMATION Continuous Individual 5" 5" Access plate 71-3/8" 47-3/8" 4' Individual 5" Access plate 35-3/8" 3' Individual Access plate 6' Individual 5" 2-3/16" 3-3/16" 9/16" Access plate FTG (9/16" Fine T-Grid) Mounting details 3" Grid center to center Wirefeed BOR FIixture STG (9/16" Slot T-Grid) Mounting details 3" Grid center to center 33" 3' EOR 44" 4' EOR 62" 6' EOR 86" 8' EOR INT Fixture EOR Fixture 3/16" End plate Mount 30" 3' INT 42" 4' INT 60" 6' INT 84" 8' INT 44-3/16" 4' BOR 62-3/16" 6' BOR 86-3/16" 8' BOR 95-3/8" 8' Individual ETG (15/16" Exposed T-Grid) Mounting details 3-1/4" Grid center to center 30" 3' INT 42" 4' INT 60" 6' INT 84" 8' INT 40" 4' BOR 58" 6' BOR 82" 8' BOR SR (Sheetrock) Mounting details 2-5/8" Rough in wide opening 33-3/16" 3' EOR 44-3/16" 4' EOR 62-3/16" 6' EOR 86-3/16" 8' EOR FSR (Flangeless Sheetrock) Mounting details 2-7/8" Rough in wide opening SHIELDING OPTIONS AND FEATURES S91 High Performance Louver S91P High Performance Louver with Acrylic Overlay S92 Satin White Lens S92HT High Transmission Lens NEO-RAY S22R Satin White Regress Lens Corner Specifications and dimensions subject to change without notice. Consult your Cooper Lighting Representative or visit www.cooperlighting.com for available options, accessories and ordering information. Cooper Lighting by Eaton | Product Selection Guide | Sixth Edition | www.cooperlighting.com 9-6 STRAIGHT & NARROW FEATURES r Direct light distribution recessed luminaire r Fully extruded aluminum housing offers precision and enhanced rigidity r Staggered lamping minimizes socket shadow in a 4" aperture r Flush and regressed lay in lens provides clean look and easy upkeep r Snap-in louver design for easy installation and better retention r Incremental lengths of 3', 4', 6' and 8' r Individual fixtures and run configurations to the nearest foot Support wire (by others) 5-1/16" Compliances may not apply to all product configurations. Please consult the product spec sheet for compliance details. COMPLIANCES: UL/cUL Listed - Damp Location, ARRA Compliant, NYC Code Compliant 23DR STRAIGHT & NARROW Ceiling panel 3-15/16" (by others) S23DR/1T8 or 2T8 ETG with lens (also available with louver) Δ SAMPLE NUMBER: 23DR-2T5-ETG-4D-UEB-SI-S93 Series Light Distribution Mounting Number of Lamps (Not Included) Lamp Type Ceiling Type Length 1 Voltage Ballast 2 23=Straight & Narrow D=Direct R=Recessed RDL=Recessed with Downlight 1=1 Lamp 2=1 Lamps T5=T5 T5HO=T5HO T8=T8 ETG=15/16" Exposed T-grid FSR=Sheetrock® (Trimless) FTG=9/16" Exposed T-grid SR=Sheetrock® (Flanged) STG=Slot T-grid 3=3' 4=4' 6=6' 8=8' xx=Continuous Runs 1=120V 2=277V 3=347V U=Universal (120-277V) DB=Dimming Ballast EB=Electronic Ballast (Standard) Switching Options Electronic Dimming Balast Options 2 Emergency 2 Fusing Shielding Options Downlight Options Optional Accessory (Downlight only) DU=Dual Switching SI=Single Switching 1=Lutron® 3 Wire Line Voltage 1% Dimming 2=Lutron® 3 Wire Line Voltage 10% Dimming 3=Lutron EcoSystem® Bus 1% Dimming 4=Lutron EcoSystem® Bus 10% Dimming 5=0-10 Volt Dimming 6=Hot & Neutral Line Voltage Dimming 7=0-10 Volt 2 Step Dimming EC=Emergency Circuit EM=Emergency Pack (Consult Factory) GLR=GLR GMF=GMF S23R=Satin White Regress Lens 3 S90=High Performance Louver S90P=High Performance Louver with Acrylic Overlay S90W=White Painted Louver S90WP=White Painted Louver with Acrylic Overlay S93=Satin White Lens S93HT=High Transmission Lens (2) MR16 F=Up to 35W (Fixed) (2) MR16A=Up to 35W (Adjustable) F1=Hex Cell Louver F2=Prismatic Spread Lens F3=Linear Spread Lens F4=Milk White Lens NOTES: Δ For some electronic, dimming and EM battery pack ballast combinations, fixture has space limitation (consult factory). Δ Standard EM Pack is for 1 lamp. Δ For dimming, specify ballast option. Δ Acrylic lenses will be slightly shorter than housing length at ambient temperature in order to compensate for normal thermal expansion during operation. Δ Due to various constraints, some options may not be combined with others. Please consult your Cooper Lighting Representative for additional information. 1. Individual fixtures cannot be combined into runs. 2. Required voltage information. Maximum ballast width=1.18". 3. Regress lens not available with T5HO lamping. MOUNTING INFORMATION FTG (9/16" Fine T-Grid) ETG (15/16" Exposed T-Grid) Mounting Details Mounting Details 4-7/8" Grid center to center 4-5/8" Grid center to center STG (9/16" Slot T-Grid) Mounting Details 4-5/8" Grid center to center SR (Sheetrock) Mounting Details 4-1/4" Rough in wide opening FSR (Flangeless Sheetrock) Mounting Details 4-1/4" Rough in wide opening NEO-RAY SHIELDING OPTIONS AND FEATURES S23R Satin White Regress Lens S90 High Performance Louver S90P High Performance Louver with Acrylic Overlay S93 Satin White Lens S93HT High Transmission Lens Corner Specifications and dimensions subject to change without notice. Consult your Cooper Lighting Representative or visit www.cooperlighting.com for available options, accessories and ordering information. 9-7 Cooper Lighting by Eaton | Product Selection Guide | Sixth Edition | www.cooperlighting.com 3-3/16" 4-3/8" 5-3/8" Compliances may not apply to all product configurations. Please consult the product spec sheet for compliance details. COMPLIANCES: UL/cUL Listed - Damp Location, ARRA Compliant, NYC Code Compliant STRAIGHT & NARROW DIRECT FEATURES rAsymmetric light distribution in a recessed luminaire rPrecise, optical reflector design provides wall illumination up to 10' r Excellent photometrics and high efficiency rSmooth wall-wash free of striations and shadows rFixtures provided in 3', 4' and 5' lengths r Light source is hidden from most viewing angles rSheetrock® run configurations to the nearest foot 23XR WALL WASH STRAIGHT & NARROW 4-1/4" ORDERING INFORMATIONΔ SAMPLE NUMBER: 23XR-1T5-ETG-4D-UEB-SI Series Mounting Number of Lamps (Not Included) Lamp Type Ceiling Type Length Section 1,2 Voltage Ballast 3 23X=Straight & Narrow Wall Wash R=Recessed 1=1 Lamp T5=T5 T5HO=T5HO ETG=15/16" Exposed T-grid FSR=Flangeless Sheetrock® FTG=9/16" Exposed T-grid SR=Sheetrock® STG=Screw Slot T-grid 3=3' 4=4' 5=5' B=Beginning of Run D=Individual E=End of Run I=Intermediate 1=120V 2=277V 3=347V U=Universal (120-277V) DB=Dimming Ballast EB=Electronic Ballast (Standard) Switching Options Emergency Fusing SI=Single Switching EM=Emergency Pack (Consult Factory) 3 GLR=GLR GMF=GMF NOTES: Δ For some electronic, dimming and EM battery pack ballast combinations, fixture has space limitation (consult factory). Δ Due to various constraints, some options may not be combined with others. Please consult your Cooper Lighting Representative for availability. 1. Fixture end plates butted end-to-end for continuous runs. 2. Runs available for Sheetrock® only. 3. Requires voltage information. MOUNTING OPTIONS ETG 15/16" T-Grid FTG 9/16" T-Grid STG 9/16" T-Grid (Slotted) SR Sheetrock FSR “Flangeless” Sheetrock NEO-RAY Specifications and dimensions subject to change without notice. Consult your Cooper Lighting Representative or visit www.cooperlighting.com for available options, accessories and ordering information. Cooper Lighting by Eaton | Product Selection Guide | Sixth Edition | www.cooperlighting.com 9-8 STRAIGHT & NARROW DIRECT 4" Octagonal J-box (by others) FEATURES r Extruded aluminum housing in 2', 3', 4', 6' or 8' illuminated sections r Trimless, high-transmission, lay-in diffuser r 120-277 voltage electronic driver certified to UL and CUL standards r Durable, low-gloss, white, powder-coated acrylic finish r Individual fixtures or run configurations r Two LED light levels r Three LED color temperatures Ceiling Panel (by others) 1/4" Ø5" Compliances may not apply to all product configurations. Please consult the product spec sheet for compliance details. COMPLIANCES: UL/cUL Listed - Damp Location, ARRA Compliant, LM79 - LM80 Compliant, NYC Code Compliant 4-1/16" 4" 22DP LED STRAIGHT & NARROW 2-3/8" S22DP LED ORDERING INFORMATIONΔ SAMPLE NUMBER: 22DP-1L35-SCETG-4D-UED-S92HT Series Light Distribution Mounting Light Level (Values Reflect 3500K, 4' Fixture) Lamp Type Mounting Type Length 22=Straight & Narrow D=Direct P=Pendant 1=Level 1, 2100 Lumens, 33 Watts 2=Level 2, 2700 Lumens, 45 Watts L30=LED, 3000K L35=LED, 3500K L40=LED, 4000K SC=Single Cable SCETG=SC on ETG SCFTG=SC on FTG SCSR=SC on SR SCSTG=SC on STG 2=2' 3=3' 4=4' 6=6' 8=8' xx=Continuous Run Voltage 1 Driver Shielding Options 1=120V 2=277V U=Universal (120-277V) DD=Dimming Driver ED=Electronic Driver S92HT=High Transmission Lens NOTES: Δ Acrylic lenses will be slightly shorter than housing length at ambient temperature in order to compensate for normal thermal expansion during operation. Δ EM Packs and J47V transformers must be remote mounted less than 10'. Feed cable distance not greater than 6'. 1. Required voltage information. MOUNTING INFORMATION Individual 2-3/16" 3-3/16" 20" Wirefeed 2-3/16" 3-3/16" Mount 24-3/8" 2' Individual 2-3/16" 3-3/16" 2-3/16" 3-3/16" 32" Wirefeed Mount Mount 36-3/8" 3' Individual 44" Wirefeed Mount 48-3/8" 4' Individual 2-3/16" 3-3/16" 3-3/16" 68" 6' BOR 92" 8' BOR Wirefeed BOR Fixture Mount Wirefeed 92" Mount 8' Individual 48" 4' INT 72" 6' INT 96" 8' INT INT Fixture 48" 4' INT 72" 6' INT 96" 8' INT 96-3/8" 36" 3' EOR 48" 4' EOR 72" 6' EOR 96" 8' EOR EOR Fixture 36-3/16" 3' EOR 48-3/16" 4' EOR 72-3/16" 6' EOR 96-3/16" 8' EOR 3/16" End Plate NEO-RAY 72-3/16" 6' BOR 96-3/16" 8' BOR 72-3/8" 6' Individual Continuous 2-3/16" 68" Wirefeed Specifications and dimensions subject to change without notice. Consult your Cooper Lighting Representative or visit www.cooperlighting.com for available options, accessories and ordering information. 9-9 Cooper Lighting by Eaton | Product Selection Guide | Sixth Edition | www.cooperlighting.com Ceiling panel (by others) 1/4" Ø5" Compliances may not apply to all product configurations. Please consult the product spec sheet for compliance details. COMPLIANCES: UL/cUL Listed - Damp Location, ARRA Compliant, NYC Code Compliant 4" 4-1/16" STRAIGHT & NARROW DIRECT FEATURES rDirect light distribution suspended luminaire rFully extruded aluminum housing offers precision and enhanced rigidity r Staggered lamping minimizes socket shadow in a 2" aperture rSnap-in louver design for easy installation and better retention rFlush and regressed lay in lens provides clean look and easy upkeep r Incremental lengths of 3', 4', 6' and 8' rIndividual fixtures and run configurations to the nearest foot 22DP STRAIGHT & NARROW 2-3/8" S22DP/1T5 with lens ORDERING INFORMATIONΔ SAMPLE NUMBER: 22DP-1T5-SCETG-8D-UEB-SI-S92 Series Light Output Mounting Number of Lamps (Not Included) Lamp Type Mounting Type Length Voltage Ballast 1 22=Straight & Narrow D=Direct P=Pendant 1=1 Lamp T5=T5 T5HO=T5HO SC=Single Cable SCETG=SC on ETG SCFTG=SC on FTG SCSR=SC on SR SCSTG=SC on STG 3=3' 4=4' 6=6' 8=8' xx=Continuous Runs 1=120V 2=277V U=Universal (120-277V) DB=Dimming Ballast EB=Electronic Ballast (Standard) Electronic Dimming Balast Options 1 Emergency 1 Fusing Shielding Options 1=Lutron® 3 Wire Line Voltage 1% Dimming 2=Lutron® 3 Wire Line Voltage 10% Dimming 3=Lutron EcoSystem® Bus 1% Dimming 4=Lutron EcoSystem® Bus 10% Dimming 5=0-10 Volt Dimming 6=Hot & Neutral Line Voltage Dimming 7=0-10 Volt 2 Step Dimming EC=Emergency Circuit EM=Emergency Pack (Consult Factory) GLR=GLR GMF=GMF S22R=Satin White Regress Lens 2 S91=High Performance Louver S91P=High Performance Louver with Acrylic Overlay S91W=White Painted Louver S91WP=White Painted Louver with Acrylic Overlay S92=Satin White Lens S92HT=High Transmission Lens NOTES: Δ For some electronic, dimming and EM battery pack ballast combinations, fixture has space limitation (consult factory). Δ Standard EM Pack is for 1 lamp. Δ For dimming, specify ballast option. Δ Acrylic lenses will be slightly shorter than housing length at ambient temperature in order to compensate for normal thermal expansion during operation. Δ Due to various constraints, some options may not be combined with others. Please consult your Cooper Lighting Representative for additional information. 1. Required voltage information. Maximum ballast width=1.18". 2. Regress lens not available with T5HO lamping. MOUNTING INFORMATION Joiner detail Individual 2-3/16" 3-3/16" 2-3/16" 3-3/16" 43" Wirefeed 2-3/16" 3-3/16" Mount 35-3/8" 3' Individual 2-3/16" 3-3/16" 71-3/8" 6' Individual 31" Wirefeed Continuous Wirefeed Mount Mount 47-3/8" 4' Individual 2-3/16" 3-3/16" 67" Wirefeed 91" Mount 8' Individual 40" 4' BOR 58" 6' BOR 82" 8' BOR Wirefeed 30" 3' INT 42" 4' INT 60" 6' INT 84" 8' INT BOR Fixture INT Fixture Mount 44-3/16" 4' BOR 62-3/16" 6' BOR 86-3/16" 8' BOR 30" 3' INT 42" 4' INT 60" 6' INT 84" 8' INT 95-3/8" 33" 3' EOR 44" 4' EOR 62" 6' EOR 86" 8' EOR EOR Fixture 33-3/16" 3' EOR 44-3/16" 4' EOR 62-3/16" 6' EOR 86-3/16" 8' EOR 3/16" End Plate SHIELDING OPTIONS S91 High Performance Louver S91P High Performance Louver with Acrylic Overlay S92 Satin White Lens NEO-RAY S22R Satin White Regress Lens S92HT High Transmission Lens Specifications and dimensions subject to change without notice. Consult your Cooper Lighting Representative or visit www.cooperlighting.com for available options, accessories and ordering information. Cooper Lighting by Eaton | Product Selection Guide | Sixth Edition | www.cooperlighting.com 9-10 STRAIGHT & NARROW DIRECT-INDIRECT FEATURES r Direct-indirect light distribution r Extruded-aluminum housing offers precise in-line appearance r Uplight and downlight illumination in a 2" aperture r Incremental lengths of 3', 4', 6' and 8' r Individual fixtures and run configurations to the nearest foot r Several high-performance louver and lens shielding options Compliances may not apply to all product configurations. Please consult the product spec sheet for compliance details. 5-5/8" COMPLIANCES: UL/cUL Listed - Damp Location, ARRA Compliant, NYC Code Compliant 22DIP STRAIGHT & NARROW 2-3/8" 22DIP with semi-specular parabolic louver (S91) down, open (up) ORDERING INFORMATIONΔ SAMPLE NUMBER: 22DIP-1T5-SCETG-4D-UEB-SI-S92 Series Light Output Mounting Number of Lamps (Not Included) Lamp Type Mounting Type Length Voltage Ballast 22=Straight & Narrow DI=Direct-Indirect P=Pendant 1x1=1 Lamp up - 1 Lamp down T5=T5 T5HO=T5HO SC=Single Cable SCETG=SC on ETG SCFTG=SC on FTG SCSR=SC on SR SCSTG=SC on STG 3=3' 4=4' 6=6' 8=8' xx=Continuous Runs 1=120V 2=277V U=Universal (120-277V) DB=Dimming Ballast EB=Electronic Ballast (Standard) Switching Option Emergency Fusing Louver Options DU=Dual Switching (2 Lamps) SI=Single Switching EM=Emergency Pack (Consult Factory) 1 GLR=GLR GMF=GMF S91=High Performance Louver S91P=High Performance Louver with Acrylic Overlay S91W=White Painted Louver S91WP=White Painted Louver with Acrylic Overlay S92=Satin White Lens NOTES: Δ For some electronic, dimming and EM battery pack ballast combinations, fixture has space limitation (consult factory). Δ Due to various constraints, some options may not be combined with others. Please consult your Cooper Lighting Representative for availability. 1. Required voltage information. MOUNTING INFORMATION 47" 71" 48-3/8" 4' IND 72-3/8" 6' IND 35" 95" 36-3/8" 3' IND 96-3/8" 8' IND DIP Mounting Assembly DP Mounting Assembly Non-feed Canopy NEO-RAY OPTICAL OPTIONS High Performance Louver Satin White Lens Continuous Line Corner Detail (consult factory) Direct-Indirect (top view) Specifications and dimensions subject to change without notice. Consult your Cooper Lighting Representative or visit www.cooperlighting.com for available options, accessories and ordering information. 9-11 Cooper Lighting by Eaton | Product Selection Guide | Sixth Edition | www.cooperlighting.com Ceiling panel (by others) 1/4" Ø5" Compliances may not apply to all product configurations. Please consult the product spec sheet for compliance details. COMPLIANCES: UL/cUL Listed - Damp Location, ARRA Compliant, NYC Code Compliant 5-1/16" STRAIGHT & NARROW DIRECT FEATURES rDirect light distribution suspended luminaire rFully extruded aluminum housing offers precision and enhanced rigidity r Staggered lamping minimizes socket shadow in a 2" aperture rSnap-in louver design for easy installation and better retention rFlush and regressed lay in lens provides clean look and easy upkeep r Incremental lengths of 3', 4', 6' and 8' rIndividual fixtures and run configurations to the nearest foot 23DP STRAIGHT & NARROW 4" S23DP/1T8 or 2T8 with lens (also available with louver) Δ SAMPLE NUMBER: 23DP-1T5-SCSTG-8D-UEB-SI-S93 Series Light Output Mounting Number of Lamps (Not Included) Lamp Type Mounting Type Length Voltage Ballast 23=Straight & Narrow D=Direct P=Pendant PDL=Pendant with Downlight 1=1 Lamp 2=2 Lamps T5=T5 T5HO=T5HO T8=T8 SC=Single Cable SCETG=SC on ETG SCFTG=SC on FTG SCSR=SC on SR SCSTG=SC on STG 3=3' 4=4' 6=6' 8=8' xx=Continuous Runs 1=120V 2=277V 3=347V U=Universal (120-277V) DB=Dimming Ballast EB=Electronic Ballast (Standard) Electronic Dimming Balast Option Switching Option Emergency 1 Fusing Shielding Options Downlight Options Optional Accessory (Downlight only) 1=Lutron® 3 Wire Line Voltage 1% Dimming 2=Lutron® 3 Wire Line Voltage 10% Dimming 3=Lutron EcoSystem® Bus 1% Dimming 4=Lutron EcoSystem® Bus 10% Dimming 5=0-10 Volt Dimming 6=Hot & Neutral Line Voltage Dimming 7=0-10 Volt 2 Step Dimming DU=Dual Switching (2 Lamps) SI=Single Switching EC=Emergency Circuit EM=Emergency Pack (Consult Factory) GLR=GLR GMF=GMF S23R=Satin White Regress Lens 2 S90=High Performance Louver S90P=High Performance Louver with Acrylic Overlay S90W=White Painted Louver S90WP=White Painted Louver with Acrylic Overlay S93=Satin White Lens S93HT=High Transmission Lens (2) MR16 F=Up to 35W (Fixed) (2) MR16A=Up to 35W (Adjustable) F1=Hex Cell Louver F2=Prismatic Spread Lens F3=Linear Spread Lens F4=Milk White Lens NOTES: Δ Acrylic lenses will be slightly shorter than housing length at ambient temperature in order to compensate for normal thermal expansion during operation. Δ For some electronic, dimming and EM battery pack ballast combinations, fixture has space limitation (consult factory). Δ Standard EM Pack is for 1 lamp. Δ Individual fixtures cannot be combined into runs. Δ Due to various constraints, some options may not be combined with others. Please consult your Cooper Lighting Representative for availability. 1. Required voltage information. 2. Regress lens not available with T5HO lamping. MOUNTING INFORMATION Individual 2-3/16" 3-3/16" Continuous 43" (1T5, 1T8, 2T5) 44" (2T8) Wirefeed 2-3/16" 3-3/16" 31" (1T5, 1T8, 2T5) 32"(2T8) Wirefeed Mount 35-3/8" (1T5, 1T8, 2T5) 36-3/8"(2T8) 3' Individual 2-3/16" 3-3/16" Mount 71-3/8" (1T5, 1T8, 2T5) 75-3/8"(2T8) 6' Individual Mount 47-3/8" (1T5, 1T8, 2T5) 47-3/8" (2T8) 4' Individual 2-3/16" 3-3/16" S23DP-1T5 67" (1T5, 1T8, 2T5) 71"(2T8) Wirefeed 2-3/16" 3-3/16" Wirefeed Mount 8' Individual 40" 4' BOR 58" 6' BOR 82" 8' BOR Wirefeed BOR Fixture Mount 44-3/16" 4' BOR 62-3/16" 6' BOR 86-3/16" 8' BOR 91" (1T5, 1T8, 2T5) 95"(2T8) S23DP-2T5 30" 3' INT 42" 4' INT 60" 6' INT 84" 8' INT INT Fixture 30" 3' INT 42" 4' INT 60" 6' INT 84" 8' INT 33" 3' EOR 44" 4' EOR 62" 6' EOR 86" 8' EOR EOR Fixture 2-3/16" 3-3/16" 3/16" End plate 2-3/16" 3-3/16" Joiner details 36" 3' INT 48" 4' INT 72" 6' INT 96" 8' INT 42" 4' EOR 90" 8' EOR INT Fixture EOR Fixture Mount 36" 3' INT 48" 4' INT 72" 6' INT 96" 8' INT 36-3/16" 3' BOR 72-3/16" 6' BOR 96-3/16" 8' BOR INT Fixture Mount 46" 4' INT 69" 6' INT 92" 8' INT 37" 3' EOR 48" 4' EOR 71" 6' EOR 94" 8' EOR EOR Fixture 3/16" End plate 37-3/16" 3' EOR 48-3/16" 4' EOR 71-3/16" 6' EOR 94-3/16" 8' EOR S23DP-1T8 32" 3' BOR 68" 6' BOR 92" 8' BOR Wirefeed BOR Fixture 46" 4' INT 69" 6' INT 92" 8' INT BOR Fixture 37-3/16" 3' BOR 71-3/16" 6' BOR 94-3/16" 8' BOR 33-3/16" 3' EOR 44-3/16" 4' EOR 62-3/16" 6' EOR 86-3/16" 8' EOR S23DP-2T8 95-3/8" (1T5, 1T8, 2T5) 99-3/8"(2T8) 33" 3' BOR 67" 6' BOR 90" 8' BOR Wirefeed 2-3/16" 3-3/16" 3/16" End plate 42-3/16" 4' EOR 90-3/16" 8' EOR 42" 4' BOR 63" 6' BOR 87" 8' BOR Wirefeed 32" 3' INT 44" 4' INT 64" 6' INT 88" 8' INT BOR Fixture INT Fixture Mount 32" 3' INT 44" 4' INT 64" 6' INT 88" 8' INT 46-3/16" 4' BOR 67-3/16" 6' BOR 91-3/16" 8' BOR 34" 3' EOR 46" 4' EOR 67" 6' EOR 91" 8' EOR EOR Fixture 3/16" End plate 34-3/16" 3' EOR 46-3/16" 4' EOR 67-3/16" 6' EOR 91-3/16" 8' EOR SHIELDING OPTIONS AND FEATURES S93, Satin White Lens S90P, High Performance Louver with Acrylic Overlay S93, Satin White Lens S93HT, High Transmission Lens Beginning or End of Run NEO-RAY S23R, Satin White Regress Lens Corner Specifications and dimensions subject to change without notice. Consult your Cooper Lighting Representative or visit www.cooperlighting.com for available options, accessories and ordering information. Cooper Lighting by Eaton | Product Selection Guide | Sixth Edition | www.cooperlighting.com 9-12 STRAIGHT & NARROW DIRECT-INDIRECT FEATURES r Direct-indirect light distribution r Extruded-aluminum housing is well suited for open-plan space design r Uplight and downlight illumination in a 4" aperture r Incremental lengths of 3', 4', 6' and 8' r Individual fixtures or continuous runs to the nearest foot r Several high-performance louver and lens shielding options r Optional MR-16 downlight offering 5-5/8" Compliances may not apply to all product configurations. Please consult the product spec sheet for compliance details. COMPLIANCES: UL/cUL Listed - Damp Location, ARRA Compliant, NYC Code Compliant 23DIP STRAIGHT & NARROW 4-1/16" 23DIP 2x1 T5 with semi-specular parabolic louver (S90) ORDERING INFORMATIONΔ SAMPLE NUMBER: 23DIP-1X1T5HO-SCSTG21-UEB-SI-S93 Series Light Output Mounting Number of Lamps (Not Included) Lamp Type Mounting Type Length Voltage Ballast 1 23=Straight & Narrow DI=DirectIndirect P=Pendant PDL=Pendant with Downlight 1x1=1 Lamp up - 1 Lamp down 1x2=1 Lamp up - 2 Lamps down 2x1=2 Lamps up - 1 Lamp down 2x2=2 Lamps up - 2 Lamps down T5=T5 T5HO=T5HO T8=T8 SC=Single Cable SCETG=SC on ETG SCFTG=SC on FTG SCSR=SC on SR SCSTG=SC on STG 3=3' 4=4' 6=6' 8=8' xx=Continuous Runs 1=120V 2=277V U=Universal (120-277V) DB=Dimming Ballast EB=Electronic Ballast (Standard) Switching Option Emergency Fusing Louver Options Downlight Options 3 Optional Accessory (Downlight only) DU=Dual Switching (2 Lamps) SI=Single Switching EM=Emergency Pack (Consult Factory) 1 GLR=GLR GMF=GMF S22R=Regressed White Acrylic Diffuser 2 S90=High Performance Louver S90P=High Performance Louver with Acrylic Overlay S93=Satin White Lens 2 S93 HT=Satin White Lens, High Transmission 2 2MR16W20=Halogen MR16 Lamp 20W (Fixed) 2MR16W20A=Halogen MR16 Lamp 20W (Adjustable) F1=Hex Cell Louver F2=Prismatic Spread Lens F3=Linear Spread Lens F4=Milk White Lens F5=Red Color Filter NOTES: Δ For some electronic, dimming and EM battery pack ballast combinations, fixture has space limitation (consult factory). Δ Due to various constraints, some options may not be combined with others. Please consult your Cooper Lighting Representative for availability. Δ T8 lamp not staggered. 1. Required voltage information. 2. Not available with 2T5HO lamp cross-section. 3. Downlight option available only in 4' and 5' individual fixtures. MOUNTING INFORMATION 47" 71" 48-3/8" 4' IND 72-3/8" 6' IND 35" 95" 36-3/8" 3' IND 96-3/8" 8' IND DIP Mounting Assembly DP Mounting Assembly Non-feed Canopy NEO-RAY SHIELDING OPTIONS AND FEATURES High Performance Louver White Louver Satin White Lens Regressed White Acrylic Diffuser Continuous Run Corner Detail 23 Direct-Indirect (top view) Specifications and dimensions subject to change without notice. Consult your Cooper Lighting Representative or visit www.cooperlighting.com for available options, accessories and ordering information. 9-13 Cooper Lighting by Eaton | Product Selection Guide | Sixth Edition | www.cooperlighting.com Wall blocking (by others) 1/8" 3-1/16" 4-1/16" Compliances may not apply to all product configurations. Please consult the product spec sheet for compliance details. COMPLIANCES: UL/cUL Listed - Damp Location, ARRA Compliant, ADA Compliant, LM79 - LM80 Compliant, NYC Code Compliant 22DW LED STRAIGHT & NARROW 2-3/8" S22DW LED STRAIGHT & NARROW DIRECT FEATURES rExtruded aluminum housing in 2', 3', 4', 6' or 8' illuminated sections rTrimless, high-transmission, lay-in diffuser r 120-277 voltage electronic driver certified to UL and CUL standards rDurable, low-gloss, white, powder-coated acrylic finish rIndividual fixtures or run configurations r Two LED light levels rThree LED color temperatures 1/2" ORDERING INFORMATIONΔ SAMPLE NUMBER: 22DW-1L35-4D-UED-S92HT Series Light Distribution Mounting Light Level (Values Reflect 3500K, 4' Fixture) Lamp Type Length Voltage 1 Driver 1 Shielding Options 22=Straight & Narrow D=Direct W=Wall 1=Level 1, 2100 Lumens, 33 Watts 2=Level 2, 2700 Lumens, 45 Watts L30=LED, 3000K L35=LED, 3500K L40=LED, 4000K 2=2' 3=3' 4=4' 6=6' 8=8' xx=Continuous Run 1=120V 2=277V U=Universal (120-277V) DD=Dimming Driver ED=Electronic Driver S92HT=High Transmission Lens NOTES: Δ Acrylic lenses will be slightly shorter than housing length at ambient temperature in order to compensate for normal thermal expansion during operation. Δ EM Packs and J47V transformers must be remote mounted less than 10'. Feed cable distance not greater than 6'. 1. Required voltage information. MOUNTING INFORMATION Individual 6-3/16" 12" Wall mount with wirefeed 24-3/8" 2' Individual 6-3/16" Wall mount with wirefeed 6-3/16" Wall mount Wall mount with wirefeed 36" 48-3/8" 4' Individual 6-3/16" 24" 60" Wall mount 36-3/8" 3' Individual Wall mount with wirefeed 6-3/16" Wall mount Wall mount with wirefeed Wall mount 72-3/8" 6' Individual 84" Wall mount 96-3/8" 8' Individual Continuous 6-3/16" Wall mount with wirefeed 60" 6' BOR 84" 8' BOR BOR Fixture 72-3/16" 6' BOR 96-3/16" 8' BOR 48" 4' INT 72" 6' INT 96" 8' INT Wall mount INT Fixture 48" 4' INT 72" 6' INT 96" 8' INT 36" 3' EOR 48" 4' EOR Wall mount 6-3/16" Wall mount EOR Fixture 36-3/16" 3' EOR 48-3/16" 4' EOR 3/16" END PLATE NEO-RAY Specifications and dimensions subject to change without notice. Consult your Cooper Lighting Representative or visit www.cooperlighting.com for available options, accessories and ordering information. Cooper Lighting by Eaton | Product Selection Guide | Sixth Edition | www.cooperlighting.com 9-14 STRAIGHT & NARROW DIRECT FEATURES r Direct light distribution in a wall-mounted luminaire r Fully extruded aluminum housing offers precision and enhanced rigidity r Staggered lamping minimizes socket shadow in a 2" aperture r Flush and regressed lay in lens provides clean look and easy upkeep r Snap-in louver design for easy installation and better retention r Incremental lengths of 3', 4', 6' and 8' r Individual fixtures and run configurations to the nearest foot Wall blocking (by others) 1/8" 3-1/16" Compliances may not apply to all product configurations. Please consult the product spec sheet for compliance details. 4-1/16" COMPLIANCES: UL/cUL Listed - Damp Location, ARRA Compliant, ADA Compliant, NYC Code Compliant 22DW STRAIGHT & NARROW 2-3/8" S22DW/1T5 LENS 1/2" ORDERING INFORMATIONΔ SAMPLE NUMBER: 22DW-1T5-4D-UEB-S92 Series Light Output Mounting Number of Lamps (Not Included) Lamp Type Length Voltage Ballast 22=Straight & Narrow D=Direct W=Wall 1=1 Lamp T5=T5 T5HO=T5HO 3D=3' 4D=4' 6D=6' 8D=8' xx=Continuous Run 1=120V 2=277V U=Universal (120-277V) DB=Electronic Ballast EB=Dimming Ballast Electronic Dimming Balast Options 1 Emergency 1 Fusing Shielding Options 1=Lutron® 3 Wire Line Voltage 1% Dimming 2=Lutron® 3 Wire Line Voltage 10% Dimming 3=Lutron EcoSystem® Bus 1% Dimming 4=Lutron EcoSystem® Bus 10% Dimming 5=0-10 Volt Dimming 6=Hot & Neutral Line Voltage Dimming 7=0-10 Volt 2 Step Dimming EC=Emergency Circuit EM=Emergency Pack (Consult Factory) GLR=GLR GMF=GMF S22R=Satin White Regress Lens 2 S91=High Performance Louver S91P=High Performance Louver with Acrylic Overlay S91W=White Painted Louver S91WP=White Painted Louver with Acrylic Overlay S92=Satin White Lens S92HT=High Transmission Lens NOTES: Δ Acrylic lenses will be slightly shorter than housing length at ambient temperature in order to compensate for normal thermal expansion during operation. Δ For some electronic, dimming and EM battery pack ballast combinations, fixture has space limitation (consult factory). Δ Standard EM Pack is for 1 lamp. Δ Individual fixtures cannot be combined into runs. Δ Due to various constraints, some options may not be combined with others. Please consult your Cooper Lighting Representative for availability. Δ For dimming, specify ballast option. 1. Required voltage information. Maximum ballast width=1.18". 2. Regress lens not available with T5HO lamping. MOUNTING INFORMATION Wall mount detail Individual 59" 35" 47-3/8" 4' IND 71-3/8" 6' IND 83" 23" 35-3/8" 3' IND 95-3/8" 8' IND Joiner detail Continuous 32" 4FT BOR 6-3/16" 50" 6FT BOR 74" 8FT BOR 33" 3FT EOR 44" 4FT EOR 62" 6FT EOR 86" 8FT EOR Wall mount BOR fixture INT fixture EOR fixture 44-3/16" 4FT BOR 62-3/16" 6FT BOR 86-3/16" 8FT BOR 30" 3FT INT 42" 4FT INT 60" 6FT INT 84" 8FT INT 33-3/16" 3FT EOR 44-3/16" 4FT EOR 62-3/16" 6FT EOR 86-3/16" 8FT EOR 6-3/16" 3/16" End plate NEO-RAY Wall mount with wirefeed 30" 3FT INT 42" 4FT INT 60" 6FT INT 84" 8FT INT Wall mount Specifications and dimensions subject to change without notice. Consult your Cooper Lighting Representative or visit www.cooperlighting.com for available options, accessories and ordering information. 9-15 Cooper Lighting by Eaton | Product Selection Guide | Sixth Edition | www.cooperlighting.com Side mounted electrical box and blocking (by others) 5-5/8" Compliances may not apply to all product configurations. Please consult the product spec sheet for compliance details. COMPLIANCES: UL/cUL Listed - Damp Location, ARRA Compliant, ADA Compliant, NYC Code Compliant 5/8" 2-3/8" STRAIGHT & NARROW DIRECT-INDIRECT FEATURES rDirect-indirect light distribution rExtruded-aluminum housing is well suited for open-plan space design r Uplight and downlight illumination in a 2" aperture rIndividual fixtures and run configurations to the nearest foot rIncremental lengths of 3', 4', 6' and 8' r Several high-performance louver and lens shielding options rADA compliant 22DIW STRAIGHT & NARROW 22DIW 1x1 with high performance louver (S91) ORDERING INFORMATIONΔ SAMPLE NUMBER: 22DIW-1x1T5-4D-UEB-SI-S92 Series Light Output Mounting Number of Lamps (Not Included) Lamp Type Length Voltage Ballast 22=Straight & Narrow DI=Direct-Indirect W=Wall 1x1=1 Lamp up - 1 Lamp down T5=T5 T5HO=T5HO 3=3' 4=4' 6=6' 8=8' xx=Continuous Runs 1=120V 2=277V U=Universal (120-277V) DB=Dimming Ballast EB=Electronic Ballast (Standard) Switching Option Emergency Fusing Louver Options DU=Dual Switching SI=Single Switching EM=Emergency Pack (Consult Factory) 1 GLR=GLR GMF=GMF S91=High Performance Louver S91P=High Performance Louver with Acrylic Overlay S91W=White Painted Louver S91WP=White Painted Louver with Acrylic Overlay S92=Satin White Lens NOTES: Δ For some electronic, dimming and EM battery pack ballast combinations, fixture has space limitation (consult factory). Δ Due to various constraints, some options may not be combined with others. Please consult your Cooper Lighting Representative for availability. 1. Required voltage information. MOUNTING INFORMATION Individual Mounting Detail 28-1/2" 40-1/2" 48-3/8" 4' IND 36-3/8" 3' IND 64-1/2" 88-1/2" 96-3/8" 8' IND 72-3/8" 6' IND Rows 1-3/16" 34"/46" 34"/46" 2" 34"/46" 1-3/16" Joining Detail 2" Overall length of run 4" 88-1/2" 72" 48" 4" 48-1/4" 96-1/4" 72" 8' INT 4' INT 6' INT (plus 3/16" endcap) (plus 3/16" endcap) 18'-3/8" (typical) OPTICAL OPTIONS Satin White Lens NEO-RAY High Performance Louver Direct-Indirect (top view) Specifications and dimensions subject to change without notice. Consult your Cooper Lighting Representative or visit www.cooperlighting.com for available options, accessories and ordering information. Cooper Lighting by Eaton | Product Selection Guide | Sixth Edition | www.cooperlighting.com 9-16 STRAIGHT & NARROW DIRECT FEATURES r Direct light distribution wall-mounted luminaire r Fully extruded aluminum housing offers precision and enhanced rigidity r Staggered lamping minimizes socket shadow in a 4" aperture r Flush and regressed lay in lens provides clean look and easy upkeep r Snap-in louver design for easy installation and better retention r Incremental lengths of 3', 4', 6' and 8' r Individual fixtures and run configurations to the nearest foot Wall blocking (by others) 4-1/2" 1/8" 3-1/16" 5-1/16" Compliances may not apply to all product configurations. Please consult the product spec sheet for compliance details. COMPLIANCES: UL/cUL Listed - Damp Location, ARRA Compliant, NYC Code Compliant 23DW STRAIGHT & NARROW 4" S23DW/1T8 or 2T8 with lens (available with louver also) ORDERING INFORMATIONΔ SAMPLE NUMBER: 23DW-1T5HO-4D-1EB-EM-GLR-S93 Series Light Output Mounting Number of Lamps (Not Included) Lamp Type Length Voltage Ballast 2 Electronic Dimming Balast Options 23=Straight & Narrow D=Direct W=Wall 1=1 Lamp 2=2 Lamps T5=T5 T5HO=T5HO T8=T8 3D=3' 4D=4' 6D=6' 8D=8' xx=Continuous Run 1 1=120V 2=277V U=Universal (120-277V) DB=Electronic Ballast EB=Dimming Ballast 1=Lutron® 3 Wire Line Voltage 1% Dimming 2=Lutron® 3 Wire Line Voltage 10% Dimming 3=Lutron EcoSystem® Bus 1% Dimming 4=Lutron EcoSystem® Bus 10% Dimming 5=0-10 Volt Dimming 6=Hot & Neutral Line Voltage Dimming 7=0-10 Volt 2 Step Dimming Switching Options Emergency 2 Fusing Shielding Options Downlight Options Optional Accessory (Downlight only) DU=Dual Switching SI=Single Switching EC=Emergency Circuit EM=Emergency Pack (Consult Factory) GLR=GLR GMF=GMF S23R=Satin White Regress Lens 3 S90=High Performance Louver S90P=High Performance Louver with Acrylic Overlay S90W=White Painted Louver S90WP=White Painted Louver with Acrylic Overlay S93=Satin White Lens S93HT=High Transmission Lens (2) MR16 F=Up to 35W (Fixed) (2) MR16A=Up to 35W (Adjustable) F1=Hex Cell Louver F2=Prismatic Spread Lens F3=Linear Spread Lens F4=Milk White Lens NOTES: Δ Acrylic lenses will be slightly shorter than housing length at ambient temperature in order to compensate for normal thermal expansion during operation. Δ For some electronic, dimming and EM battery pack ballast combinations, fixture has space limitation (consult factory). Δ Standard EM Pack is for 1 lamp. Δ Due to various constraints, some options may not be combined with others. Please consult your Cooper Lighting Representative for availability. 1. Patterns are not available with 2T8 continuous runs. 2. Required voltage information. 3. Regress lens not available with T5HO lamping. MOUNTING INFORMATION Individual 23" (1T5, 1T8, 2T5) 24" 6-3/16" 6-3/16" (2T8) Wall Wall mount Wall mount mount with wirefeed with wirefeed 35-3/8" 3' Individual (1T5, 1T8, 2T5) 8' Individual 36-3/8"(2T8) 6-3/16" Wall mount with wirefeed 4' Individual Joiner detail 35"(1T5, 1T8, 2T5) 6-3/16" 36" (2T8) Wall Wall mount mount with wirefeed 47-3/8" (1T5, 1T8, 2T5) 48-3/8"(2T8) 6' Individual 83"(1T5, 1T8, 2T5) 87"(2T8) Wall mount 95-3/8"(1T5, 1T8, 2T5) 99-3/8"(2T8) 59"(1T5, 1T8, 2T5) 63"(2T8) 71-3/8"(1T5, 1T8, 2T5) 75-3/8"(2T8) Wall mount detail Wall mount Continuous 30" 3' INT S23DW-1T5 42" 4' INT 32" 4' BOR 60" 6' INT 50" 6' BOR 6-3/16" 84" 8' INT 74" 8' BOR Wall mount Wall BOR Fixture INT Fixture mount with 30" 3' INT wirefeed 42" 4' INT 44-3/16" 4' BOR 60" 6' INT 62-3/16" 6' BOR 84" 8' INT 86-3/16" 8' BOR 32" 3' INT S23DW-1T8 44" 4' INT 32" 4' BOR 64" 6' INT 55" 6' BOR 6-3/16" 88" 8' INT 79" 8' BOR Wall mount Wall BOR Fixture INT Fixture mount with 32" 3' INT wirefeed 44" 4' INT 46-3/16" 4' BOR 64" 6' INT 67-3/16" 6' BOR 88" 8' INT 91-3/16" 8' BOR 33" 3' EOR 44" 4' EOR 62" 6' EOR 86" 8' EOR Wall mount EOR Fixture 33-3/16" 3' EOR 44-3/16" 4' EOR 62-3/16" 6' EOR 86-3/16" 8' EOR 34" 3' EOR 46" 4' EOR 67" 6' EOR 91" 8' EOR Wall mount EOR Fixture 34-3/16" 3' EOR 46-3/16" 4' EOR 67-3/16" 6' EOR 91-3/16" 8' EOR 6-3/16" 3/16" End plate 6-3/16" 3/16" End plate NEO-RAY SHIELDING OPTIONS S23R Satin White Regress Lens S90 High Performance Louver S90P High Performance Louver with Acrylic Overlay S93 Satin White Lens S93HT High Transmission Lens Specifications and dimensions subject to change without notice. Consult your Cooper Lighting Representative or visit www.cooperlighting.com for available options, accessories and ordering information. 9-17 Cooper Lighting by Eaton | Product Selection Guide | Sixth Edition | www.cooperlighting.com STRAIGHT & NARROW FEATURES rAsymmetric direct-indirect or direct-indirect light distribution rExtruded-aluminum housing offers precise in-line appearance r Uplight and downlight illumination in a 4" aperture rIndividual fixtures and run configurations to the nearest foot rIncremental lengths of 3', 4', 6' and 8' r Several high-performance louver and lens shielding options Side Mounted electrical box and blocking (by others) 5-5/8" Compliances may not apply to all product configurations. Please consult the product spec sheet for compliance details. COMPLIANCES: UL/cUL Listed - Damp Location, ARRA Compliant, NYC Code Compliant 4" 23ADIW, 23DIW STRAIGHT & NARROW 5/8" 23ADIW 1x1 with semi-specular parabolic louver (S90) down, open up ORDERING INFORMATIONΔ SAMPLE NUMBER: 23DIW-1x1T5-4D-UEB-SI-S93 Series Light Output Mounting Number of Lamps (Not Included) Lamp Type Length Voltage Ballast 23=Straight & Narrow 23A=Asymmetric Straight & Narrow DI=Direct-Indirect W=Wall 1x1=1 Lamp up - 1 Lamp down 1x2=1 Lamp up - 2 Lamps down 2x1=2 Lamps up - 1 Lamp down 2x2=2 Lamps up - 2 Lamps down T5=T5 T5HO=T5HO T8=T8 3=3' 4=4' 6=6' 8=8' xx=Continuous Runs 1=120V 2=277V 3=347V U=Universal (120-277V) DB=Dimming Ballast EB=Electronic Ballast (Standard) Switching Option Emergency Fusing Louver Options DU=Dual Switching (2 lamps) SI=Single Switching EM=Emergency Pack (Consult Factory) 1 GLR=GLR GMF=GMF S22R=Regressed White Acrylic Diffuser 2 S90=High Performance Louver S90P=High Performance Louver with Acrylic Overlay S90W=White Painted Louver S90WP=White Painted Louver with Acrylic Overlay S93=Satin White Lens S93 HT=Satin White Lens, High Transmission 2 NOTES: Δ For some electronic, dimming and EM battery pack ballast combinations, fixture has space limitation (consult factory). Δ Due to various constraints, some options may not be combined with others. Please consult your Cooper Lighting Representative for availability. Δ T8 lamp not staggered. Δ 23DW T5 or T5HO standard with 6' staggered lamps. 1. Required voltage information. 2. Not available with 2T5HO lamp cross-section. MOUNTING INFORMATION Individual 40-1/2" 64-1/2" 48-3/8" 4' IND Rows 1-3/16" 34/46" 34/46" 34/46" 2" 88-1/2" 28-1/2" 96-3/8" 8' IND 36-3/8" 3' IND 72-3/8" 6' IND 4" 4" 48" 72" 72" 48-1/4" 4' INT 6' INT (plus 3/16" endcap) 18'-3/8" (typical) 88-1/2" 96-1/4" 8' INT (plus 3/16" endcap) 1-3/16" 2" Overall length of run Mounting Detail Joining Detail OPTICAL OPTIONS White Louver Satin White Lens Regressed White Acrylic Diffuser Continuous Run 23 Direct-Indirect (top view) Staggered Lamps (DP T5 and T5HO only) Specifications and dimensions subject to change without notice. Consult your Cooper Lighting Representative or visit www.cooperlighting.com for available options, accessories and ordering information. Cooper Lighting by Eaton | Product Selection Guide | Sixth Edition | www.cooperlighting.com 9-18 NEO-RAY High Performance Louver STRAIGHT & NARROW DIRECT FEATURES r Extruded aluminum housing in 2', 3', 4', 6' or 8' illuminated sections r Trimless, high-transmission, lay-in diffuser r 120-277 voltage electronic driver certified to UL and CUL standards r Durable, low-gloss, white, powder-coated acrylic finish r Individual fixtures or run configurations r Two LED light levels r Three LED color temperatures Surface blocking (by others) Compliances may not apply to all product configurations. Please consult the product spec sheet for compliance details. COMPLIANCES: UL/cUL Listed - Damp Location, ARRA Compliant, LM79 - LM80 Compliant, NYC Code Compliant 4-1/16" STRAIGHT & NARROW 2-3/8" S22 DS LED ORDERING INFORMATIONΔ SAMPLE NUMBER: 22DS-1L35-ETG-4D-UED-S92HT Series Light Distribution Mounting Light Level (Values Reflect 3500K, 4' Fixture) Lamp Type Ceiling Type Length Voltage Driver 1 22=Straight & Narrow D=Direct S=Surface 1=Level 1, 2100 Lumens, 33 Watts 2=Level 2, 2700 Lumens, 45 Watts L30=LED, 3000K L35=LED, 3500K L40=LED, 4000K ETG=15/16" Exposed T-grid FTG=9/16" Exposed T-grid SR=Sheetrock® (Flanged) STG=Slot T-grid 2=2' 3=3' 4=4' 6=6' 8=8' xx=Continuous Run 1=120V 2=277V U=Universal (120-277V) DD=Dimming Driver ED=Electronic Driver Shielding Options S92HT=High Transmission Lens NOTES: Δ Acrylic lenses will be slightly shorter than housing length at ambient temperature in order to compensate for normal thermal expansion during operation. Δ EM Packs and J47V transformers must be remote mounted less than 10'. Feed cable distance not greater than 6'. 1. Required voltage information. MOUNTING INFORMATION Individual 20" Wirefeed 2-3/16" 9/16" 2-3/16" 32" Wirefeed 2-3/16" 9/16" Mount 24-3/8" 2' Individual 44" Wirefeed 2-3/16" 9/16" 68" Wirefeed 9/16" Mount 36-3/8" 3' Individual 2-3/16" Mount 6' Individual Wirefeed 72-3/8" 92" 9/16" Mount 48-3/8" 4' Individual Mount 8' Individual 96-3/8" Continuous 2-3/16" 3-3/16" 48" 4FT INT 72" 6FT INT 96" 8FT INT 36" 3FT EOR 48" 4FT EOR INT Fixture EOR Fixture Wirefeed BOR Fixture Mount 72-3/16" 6FT BOR 96-3/16" 8FT BOR 48" 4FT INT 72" 6FT INT 96" 8FT INT 36-3/16" 3FT EOR 48-3/16" 4FT EOR 3/16" End Plate NEO-RAY 9/16" 68" 6FT BOR 92" 8FT BOR Specifications and dimensions subject to change without notice. Consult your Cooper Lighting Representative or visit www.cooperlighting.com for available options, accessories and ordering information. 9-19 Cooper Lighting by Eaton | Product Selection Guide | Sixth Edition | www.cooperlighting.com Surface blocking (by others) Compliances may not apply to all product configurations. Please consult the product spec sheet for compliance details. 4-1/16" COMPLIANCES: UL/cUL Listed - Damp Location, ARRA Compliant, NYC Code Compliant STRAIGHT & NARROW DIRECT FEATURES rDirect light distribution surface mounted rFully extruded aluminum housing offers precision and enhanced rigidity r Staggered lamping minimizes socket shadow in a 2" aperture rFlush and regressed lay in lens provides clean look and easy upkeep rSnap-in louver design for easy installation and better retention r Incremental lengths of 3', 4', 6' and 8' rIndividual fixtures and run configurations to the nearest foot 22DS STRAIGHT & NARROW 2-3/8" S22DS/1T5 LENS ORDERING INFORMATIONΔ SAMPLE NUMBER: 22DS-1T5-STG-4D-UEB-S22R Series Light Output Mounting Number of Lamps (Not Included) Lamp Type Ceiling Type Length Voltage 1 Ballast 1 22=Straight & Narrow D=Direct S=Surface 1=1 Lamp T5=T5 T5HO=T5HO ETG=15/16" Exposed T-grid FTG=9/16" Exposed T-grid SR=Sheetrock® (Flanged) STG=Slot T-grid 3D=3' 4D=4' 6D=6' 8D=8' xx=Continuous Run 1=120V 2=277V U=Universal (120-277V) DB=Electronic Ballast EB=Dimming Ballast Electronic Dimming Balast Options 1 Emergency Fusing Shielding Options 1=Lutron® 3 Wire Line Voltage 1% Dimming 2=Lutron® 3 Wire Line Voltage 10% Dimming 3=Lutron EcoSystem® Bus 1% Dimming 4=Lutron EcoSystem® Bus 10% Dimming 5=0-10 Volt Dimming 6=Hot & Neutral Line Voltage Dimming 7=0-10 Volt 2 Step Dimming EC=Emergency Circuit EM=Emergency Pack (Consult Factory) 1 GLR=GLR GMF=GMF S22R=Satin White Regress Lens 2 S91=High Performance Louver S91P=High Performance Louver with Acrylic Overlay S91W=White Painted Louver S91WP=White Painted Louver with Acrylic Overlay S92=Satin White Lens S92HT=High Transmission Lens NOTES: Δ Acrylic lenses will be slightly shorter than housing length at ambient temperature in order to compensate for normal thermal expansion during operation. Δ For some electronic, dimming and EM battery pack ballast combinations, fixture has space limitation (consult factory). Δ Standard EM Pack is for 1 lamp. Δ Due to various constraints, some options may not be combined with others. Please consult your Cooper Lighting Representative for availability. Δ For dimming, specify ballast option. 1. Required voltage information. For dimming, specify driver option. EM Packs and J47V transformers must be remote mounted. Acrylic lenses will be slightly shorter than housing length at ambient temperature in order to compensate for normal thermal expansion. 2. Regress lens not available with T5HO lamping. MOUNTING INFORMATION Joiner details Individual 43" Wirefeed 2-3/16" 67" 2-3/16" Wirefeed 9/16" 9/16" Mount 47-3/8" 4' Individual Mount 31" Wirefeed 2-3/16" 71-3/8" 6' Individual 2-3/16" 9/16" 91" Wirefeed 9/16" Mount 35-3/8" 3' Individual Mount 95-3/8" 8' Individual Continuous 2-3/16" 3-3/16" 9/16" 40" 4' BOR 58" 6' BOR 82" 8' BOR Wirefeed 30" 3' INT 42" 4' INT 60" 6' INT 84" 8' INT BOR Fixture INT Fixture Mount 44-3/16" 4' BOR 62-3/16" 6' BOR 86-3/16" 8' BOR 30" 3' INT 42" 4' INT 60" 6' INT 84" 8' INT 33" 3' EOR 44" 4' EOR 62" 6' EOR 86" 8' EOR EOR Fixture 33-3/16" 3' EOR 44-3/16" 4' EOR 62-3/16" 6' EOR 86-3/16" 8' EOR 3/16" End plate SHIELDING OPTIONS S91 High Performance Louver S91P High Performance Louver with Acrylic Overlay S92 Satin White Lens NEO-RAY S22R Satin White Regress Lens S92HT High Transmission Lens Specifications and dimensions subject to change without notice. Consult your Cooper Lighting Representative or visit www.cooperlighting.com for available options, accessories and ordering information. Cooper Lighting by Eaton | Product Selection Guide | Sixth Edition | www.cooperlighting.com 9-20 STRAIGHT & NARROW DIRECT Surface blocking (by others) FEATURES r Direct light distribution surface mounted r Fully extruded aluminum housing offers precision and enhanced rigidity r Staggered lamping minimizes socket shadow in a 4" aperture r Flush and regressed lay in lens provides clean look and easy upkeep r Snap-in louver design for easy installation and better retention r Incremental lengths of 3', 4', 6' and 8' r Individual fixtures and run configurations to the nearest foot Compliances may not apply to all product configurations. Please consult the product spec sheet for compliance details. COMPLIANCES: UL/cUL Listed - Damp Location, ARRA Compliant, NYC Code Compliant 5" 5-1/16" 23DS STRAIGHT & NARROW 4" S23DS/1T8 or 2T8 with lens (also available with louver) Δ SAMPLE NUMBER: 23DS-2T5-STG-8D-SI-S93 Series Light Output Mounting Number of Lamps (Not Included) Lamp Type Ceiling Type Length Voltage Ballast 1 23=Straight & Narrow D=Direct S=Surface SDL=Surface with Downlight 1=1 Lamp 2=2 Lamps T5=T5 T5HO=T5HO T8=T8 ETG=15/16" Exposed T-grid FTG=9/16" Exposed T-grid SR=Sheetrock® (Flanged) STG=Slot T-grid 3D=3' 4D=4' 6D=6' 8D=8' xx=Continuous Run 1=120V 2=277V 3=347V U=Universal (120-277V) DB=Electronic Ballast EB=Dimming Ballast Electronic Dimming Balast Options Switching Options Emergency 1 Fusing Shielding Options Downlight Options Optional Accessory (Downlight only) 1=Lutron® 3 Wire Line Voltage 1% Dimming 2=Lutron® 3 Wire Line Voltage 10% Dimming 3=Lutron EcoSystem® Bus 1% Dimming 4=Lutron EcoSystem® Bus 10% Dimming 5=0-10 Volt Dimming 6=Hot & Neutral Line Voltage Dimming 7=2 Step Dimming DU=Dual Switching SI=Single Switching EC=Emergency Circuit EM=Emergency Pack (Consult Factory) GLR=GLR GMF=GMF S23R=Satin White Regress Lens 2 S90=High Performance Louver S90P=High Performance Louver with Acrylic Overlay S90W=White Painted Louver S90WP=White Painted Louver with Acrylic Overlay S93=Satin White Lens S93HT=High Transmission Lens (2) MR16 F=Up to 35W (Fixed) (2) MR16A=Up to 35W (Adjustable) F1=Hex Cell Louver F2=Prismatic Spread Lens F3=Linear Spread Lens F4=Milk White Lens NOTES: Δ Acrylic lenses will be slightly shorter than housing length at ambient temperature in order to compensate for normal thermal expansion during operation. Δ For some electronic, dimming and EM battery pack ballast combinations, fixture has space limitation (consult factory). Δ Standard EM Pack is for 1 lamp. Δ Due to various constraints, some options may not be combined with others. Please consult your Cooper Lighting Representative for availability. 1. Required voltage information. 2. Regress lens not available with T5HO lamping. MOUNTING INFORMATION Individual 2-3/16" 3-3/16" 1" Continuous 43" (1T5, 1T8, 2T5) 44" (2T8) Wirefeed 1" Mount 47-3/8" (1T5, 1T8, 2T5) 48-3/8" (2T8) 4' Individual 2-3/16" 3-3/16" 1" 31" (1T5, 1T8, 2T5) 32" (2T8) Wirefeed Mount 35-3/8" (1T5, 1T8, 2T5) 36-3/8" (2T8) 3' Individual 67" (1T5, 1T8, 2T5) 71" (2T8) Wirefeed 2-3/16" 3-3/16" S23DS-1T5 2-3/16" 3-3/16" 1" Mount 71-3/8" (1T5, 1T8, 2T5) 75-3/8" (2T8) 6' Individual 2-3/16" 3-3/16" 1" 95-3/8" (1T5, 1T8, 2T5) 99-3/8" (2T8) 30" 3' INT 42" 4' INT 60" 6' INT 84" 8' INT BOR Fixture INT Fixture Mount 44-3/16" 4' BOR 62-3/16" 6' BOR 86-3/16" 8' BOR 91" (1T5, 1T8, 2T5) 95" (2T8) Wirefeed Mount 40" 4' BOR 58" 6' BOR 82" 8' BOR Wirefeed S23DS-1T8 2-3/16" 3-3/16" 1" Joiner details 8' Individual 30" 3' INT 42" 4' INT 60" 6' INT 84" 8' INT 42" 4' BOR 63" 6' BOR 87" 8' BOR Wirefeed 32" 3' INT 44" 4' INT 64" 6' INT 88" 8' INT BOR Fixture INT Fixture Mount 44-3/16" 4' BOR 62-3/16" 6' BOR 86-3/16" 8' BOR 30" 3' INT 42" 4' INT 60" 6' INT 84" 8' INT 33" 3' EOR 44" 4' EOR 62" 6' EOR 86" 8' EOR EOR Fixture 33-3/16" 3' EOR 44-3/16" 4' EOR 62-3/16" 6' EOR 86-3/16" 8' EOR 3/16" End plate 34" 3' EOR 46" 4' EOR 67" 6' EOR 91" 8' EOR EOR Fixture 33-3/16" 3' EOR 44-3/16" 4' EOR 67-3/16" 6' EOR 91-3/16" 8' EOR 3/16" End plate NEO-RAY SHIELDING OPTIONS S23R Satin White Regress Lens S90 High Performance Louver S90P High Performance Louver with Acrylic Overlay S93 Satin White Lens S93HT High Transmission Lens Specifications and dimensions subject to change without notice. Consult your Cooper Lighting Representative or visit www.cooperlighting.com for available options, accessories and ordering information. 9-21 Cooper Lighting by Eaton | Product Selection Guide | Sixth Edition | www.cooperlighting.com 6-15/16" 4-7/16" 4" Compliances may not apply to all product configurations. Please consult the product spec sheet for compliance details. COMPLIANCES: UL/cUL Listed - Damp Location, ARRA Compliant, NYC Code Compliant 9/16" 5-3/8" RECESSED LINEAR DIRECT FEATURES rDirect light distribution recessed luminaire rAluminum extruded housing and formed-steel reflector r Fully recessed mounting in acoustic tile or Sheetrock® ceilings rUnique, free floating, lensed micro-louver rSemi-specular aluminum louver with 1/2" high cross blades on 1" center r High efficiency rDurable, low gloss, white, powder-coated finish rIndividual fixtures or continuous runs to the nearest foot r Compatible with all 6" on-center ceiling systems 3/16" VERSYS 1B 6" ORDERING INFORMATION SAMPLE NUMBER: 1BR-1T5-4-UEB-STG-S41 Series Mounting Number of Lamps (Not Included) Lamp Type Run Length/Nominal Length Voltage Ballast Ceiling Type 2 Emergency 1B R=Recessed 1=1 Lamp T5=T5 T5HO=T5HO 2=30" Fixture (1) 2' Lamp 3=36" Fixture (1) 2' Lamp 4=48" Fixture (1) 3' Lamp 5=60" Fixture (1) 4' Lamp 8=96" Fixture (2) 3' Lamp XX=Run Length 1=120V 2=277V 3=347V U=Universal (120-277V) DB=Dimming Ballast 1 EB=Electronic Ballast ETG=15/16"W x 1 1/2"H T-grid FSR=Sheetrock® (Flangeless) SR=Sheetrock® (Flanged) STG=9/16" W x 1 3/4"H Slot T-grid EM=Emergency Battery Pack 1 Fusing Cover Plate Shielding GLR=Fast Blow Fuse GMF=Slow Blow Fuse BC=Blank Cover Plate 3 S41=Floating Louver with High Transmission Overlay 4 S42=Floating Composite Louver NOTES: 1. Specify manufacturer, catalog number. 2. Consult factory for other ceiling types. 3. Continuous run fixture option only - all other utility module options quoted and ordered separately based upon plans and specifications. 4. For T5 lamping only. CEILING MOUNTING DETAILS ROD Ø1/4" not by Neo-Ray ETG 15/16” exposed T-Grid STG 9/16” Slot T-Grid SR Sheetrock ROD Ø1/4" not by Neo-Ray FSR Flangeless Sheetrock CONTINUOUS RUN DETAILS Typical Run using 5' and 2-1/2' (30") fixture modules 17' 6" 5' 5' 2-1/2' (30") BOR INT INT EOR Typical End Filler Utility Modules. Nominally 6" x 6" NEO-RAY 5' Typical End Filler Specifications and dimensions subject to change without notice. Consult your Cooper Lighting Representative or visit www.cooperlighting.com for available options, accessories and ordering information. Cooper Lighting by Eaton | Product Selection Guide | Sixth Edition | www.cooperlighting.com 9-22 RECESSED LINEAR DIRECT FEATURES r Direct light distribution r Extruded-aluminum 2" regressed trim with mitered corners r Die-formed 20-gauge steel housing recessed in 4', 5' and 8' sections r Regressed white acrylic lens or high-transmission lens offering r Individual or continuous run fixtures r Compatible with all 6" on-center ceiling systems 5-29/32" [150mm] 1-1/2" [38mm] Compliances may not apply to all product configurations. Please consult the product spec sheet for compliance details. COMPLIANCES: UL/cUL Listed - Damp Location, ARRA Compliant, NYC Code Compliant 2-1/4" 5-1/8" [130mm] 5-3/8" [137mm] 6" [152mm] ORDERING INFORMATIONΔ SAMPLE NUMBER: 7A-648R-2T5-ETG-UEB-SI-S22 Series Fixture Size Mounting Number of Lamps (Not Included) Lamp Type Ceiling Type Length Voltage 1 7A=2 1/4" Regressed Lens 6=Continuous Runs 648=6"x48" 660=6"x60" 696=6"x96" R=Recessed 1=1 Lamp 2=2 Lamps T5=T5 T5HO=T5HO T8=T8 ETG=Exposed T-grid SR=Sheetrock® (flanged) STG=Slot T-grid XX=Replace XX with Length of Continuous Run 1=120V 2=277V 3=347V U=Universal (120-277V) Ballast Switching Options Emergency Fusing Shielding Options DB=Dimming Ballast EB=Electronic Ballast (Standard) DU=Dual Switching (2 Lamps) SI=Single Switching EM=Emergency Pack (Consult Factory) GLR=GLR GMF=GMF 95HT=1/8" High Transmission Acrylic Lens S22=3/16" White Acrylic Lens NOTES: Δ Individual fixtures cannot be combined into runs. 1. Not all options available. Please consult your Cooper Lighting Representative for availability. MOUNTING INFORMATION STANDARD LUMINAIRE VIEW 6" x 48" [158mm x 1219mm] 6" x 60" [158mm x 1524mm] 6" x 96" [158mm x 2438mm] ETG Exposed T-Grid SR Sheetrock STG Slot T-Grid CONTINUOUS RUN CONFIGURATION BOR = Beginning of run 96" - 8' BOR 72" - 6' BOR 60" - 5' BOR 48" - 4' BOR 36" - 3' BOR INT = Intermediate 96" - 8' INT 72" - 6' INT 60" - 5' INT 48" - 4' INT 36" - 3' INT EOR = End of run 96" - 8' EOR 72" - 6' EOR 60" - 5' EOR 48" - 4' EOR 36" - 3' EOR NEO-RAY Overall length of run Specifications and dimensions subject to change without notice. Consult your Cooper Lighting Representative or visit www.cooperlighting.com for available options, accessories and ordering information. 9-23 Cooper Lighting by Eaton | Product Selection Guide | Sixth Edition | www.cooperlighting.com 6-1/4" [159mm] Compliances may not apply to all product configurations. Please consult the product spec sheet for compliance details. COMPLIANCES: UL/cUL Listed - Damp Location, ARRA Compliant, NYC Code Compliant 9-1/8" [232mm] RECESSED LINEAR DIRECT 8-3/4" [222mm] FEATURES rDirect light distribution r3' or 4' individual sections r Die-formed 20-gauge steel housing rFor 15/16" exposed T-grid ceiling systems rRigid U-shaped, double-formed trim with 3/8" regress soft-lit edge r Three light diffuser options available 41 ORDERING INFORMATION SAMPLE NUMBER: 41R-2T5-4D-1EB-SI-S22 Series Mounting Number of Lamps (Not Included) Lamp Type Run Length Voltage 1 Ballast Switching Options 41=ETG - Exposed T-grid Ceiling R=Recessed 1=1 Lamp 2=2 Lamps 3=3 Lamps TT5=T5 T5HO=T5HO T8=T8 Overall Nominal Run Length __ ft. 1=120V 2=277V 3=347V DB=Dimming Ballast EB=Electronic Ballast (Standard) DU=Double Switching SI=Single Switching Emergency Fusing Shielding Options EM=Emergency Pack (Consult Factory) GLR=GLR S22=White Acrylic Diffuser S58=KSH-12 Acrylic Lens S72=Bold Baffle S79=Parabolic Baffle NOTES: 1. Not all options available. Please consult your Cooper Lighting Representative for availability. MOUNTING INFORMATION 48" [1219mm] 48" [1219mm] SHIELDING OPTIONS S72 Bold Baffle S79 Parabolic Baffle NEO-RAY S58 Acrylic Lens 90° Mitered Baffle Specifications and dimensions subject to change without notice. Consult your Cooper Lighting Representative or visit www.cooperlighting.com for available options, accessories and ordering information. Cooper Lighting by Eaton | Product Selection Guide | Sixth Edition | www.cooperlighting.com 9-24 RECESSED LINEAR FEATURES r Direct light distribution r Die-formed 20-gauge steel housing for 3', 4', 6' and 8' sections r Individual and continuous runs for mounting in a Sheetrock® ceiling r Run lengths provided to the nearest foot r Two and three lamp options r Rigid U-shaped, double-formed trim with 3/8" regress soft-lit edge r Multiple shielding options 8-3/4" [223mm] 6-1/4" [159mm] Compliances may not apply to all product configurations. Please consult the product spec sheet for compliance details. COMPLIANCES: UL/cUL Listed - Damp Location, ARRA Compliant, NYC Code Compliant 7-3/4" [197mm] 9" [229mm] Ceiling opening 9-3/4" [248mm] 42 ORDERING INFORMATION SAMPLE NUMBER: 42R-2T8-60-1EB-SI-S58 Series Mounting Number of Lamps (Not Included) Lamp Type Run Length Voltage 1 Ballast Switching Options Emergency 42=42 R=Recessed 2=2 Lamps 3=3 Lamps T5=T5 T5HO=T5HO T8=T8 Overall Nominal Run Length __ ft. 1=120V 2=277V 3=347V DB=Dimming Ballast EB=Electronic Ballast (Standard) DU=Double Switching SI=Single Switching EM=Emergency Pack (Consult Factory) Fusing Shielding Options GLR=GLR GMF=GMF S58=KSH-12 Acrylic Lens S72=Bold Baffle S79=Parabolic Baffle NOTES: 1. Not all options available. Please consult your Cooper Lighting Representative for availability. RUNS AND PATTERNS 5" [127mm] 72" [1829mm] 96" [2438mm] 36" [914mm] 48" [1219mm] 19" [483mm] 19" [483mm] 5" [127mm] 5" [127mm] 90° Mitered corner 12" Non-illuminated fill-in (optional) Illuminated runs are provided In 1' increments Mounting Hole Legend 7/8" diameter hole Illuminated patterns are provided In 1' increments plus 10" mitered corner. NEO-RAY SHIELDING OPTIONS S58 Acrylic Lens S72 Bold Baffle S79 Parabolic Baffle 90° Mitered Baffle Specifications and dimensions subject to change without notice. Consult your Cooper Lighting Representative or visit www.cooperlighting.com for available options, accessories and ordering information. 9-25 Cooper Lighting by Eaton | Product Selection Guide | Sixth Edition | www.cooperlighting.com Compliances may not apply to all product configurations. Please consult the product spec sheet for compliance details. COMPLIANCES: UL/cUL Listed - Damp Location, ARRA Compliant, NYC Code Compliant 9-5/16" [237mm] Surface to ceiling 73SS 8-3/4" [222mm] Ceiling to ceiling 73CC RECESSED LINEAR DIRECT FEATURES rDirect wall wash perimeter light distribution rRecessed, staggered light strips for even illumination r Architectural soffit and cove-mounting for all ceiling conditions rExtruded-aluminum ceiling trim with soft-lit edge rField-adjustable runs r Four shielding options rDimming and emergency options 73 9-1/32" [229mm] Surface to ceiling 73SC ORDERING INFORMATIONΔ SAMPLE NUMBER: 73-CC-2T8-4D-1EB-SI-S22 Series Mounting Number of Lamps (Not Included) Lamp Type Run Length Voltage 1 Ballast Switching Options Emergency Fusing 73=Perimeter CC=Ceiling to Ceiling SC=Surface to Ceiling SS=Surface to Surface 1=1 Lamp 2=2 Lamps T5=T5 T5HO=T5HO T8=T8 Overall Nominal Run Length __ ft. 1=120V 2=277V 3=347V DB=Dimming Ballast EB=Electronic Ballast (Standard) DU=Double Switching SI=Single Switching EM=Emergency Pack (Consult Factory) GLR=GLR GMF=GMF Shielding Options S22=White Acrylic Diffuser S58=KSH-12 Acrylic Lens S72=Bold Baffle S79=Parabolic Baffle NOTES: Δ Fixture consists of Lighting Strip, Shielding and Extruded Rails. 1. Not all options available. Please consult your Cooper Lighting Representative for availability. SHIELDING OPTIONS S58 Acrylic Lens S72 Bold Baffle S79 Parabolic Baffle NEO-RAY S22 Acrylic Diffuser 90° Mitered Baffle Specifications and dimensions subject to change without notice. Consult your Cooper Lighting Representative or visit www.cooperlighting.com for available options, accessories and ordering information. Cooper Lighting by Eaton | Product Selection Guide | Sixth Edition | www.cooperlighting.com 9-26 RECESSED LINEAR FEATURES r Direct light distribution r Die-formed 20-gauge steel housing, nominal 3', 4', 6' and 8' sections r Staggered lamps for even illumination r Runs are field-adjustable r Optional 90° mitered corners r Extruded-aluminum ceiling trims with 3/8" soft-lit edge r Fixture flange will accept ceiling tile or Sheetrock® r Selection of shielding options 6-3/8" 8" Compliances may not apply to all product configurations. Please consult the product spec sheet for compliance details. COMPLIANCES: UL/cUL Listed - Damp Location, ARRA Compliant, NYC Code Compliant 7-11/16" 9-1/4" Ceiling opening 77 9-11/16" ORDERING INFORMATIONΔ SAMPLE NUMBER: 77-2T8-24'-1EB-SI-S79 Series Number of Lamps (Not Included) Lamp Type Run Length Voltage 1 Ballast Switching Options Emergency Fusing 77=77 1=1 Lamp 2=2 Lamps T5=T5 T5HO=T5HO T8=T8 Overall Nominal Run Length __ ft. 1=120V 2=277V 3=347V DB=Dimming Ballast EB=Electronic Ballast (Standard) DU=Double Switching SI=Single Switching EM=Emergency Pack (Consult Factory) GLR=GLR GMF=GMF Shielding Options S58M=KSH-12 Acrylic Lens S72=Bold Baffle S79=Parabolic Baffle NOTES: Δ Fixture must be installed prior to ceiling. 1. Not all options available. Please consult your Cooper Lighting Representative for availability. RUNS AND PATTERNS 12-1/16" inside mitered corner Standard illuminated sections contain mitered corners installed continuous and unbroken, and are field cut to suit. Utilize 8', 6' and 4' steel luminaires with 4' aluminum end for field cutting. Standard illuminated sections Field cut to suit NEO-RAY SHIELDING OPTIONS S58-KSH-12 Acrylic Lens S72 Bold Baffle S79 Parabolic Baffle 90° Mitered Baffle Specifications and dimensions subject to change without notice. Consult your Cooper Lighting Representative or visit www.cooperlighting.com for available options, accessories and ordering information. 9-27 Cooper Lighting by Eaton | Product Selection Guide | Sixth Edition | www.cooperlighting.com 6" [153mm] 6-1/4" [159mm] Compliances may not apply to all product configurations. Please consult the product spec sheet for compliance details. COMPLIANCES: UL/cUL Listed - Damp Location, ARRA Compliant, NYC Code Compliant RECESSED LINEAR DIRECT FEATURES rDirect light distribution rRecessed fixture for 15/16" grid ceilings r Die-formed 20-gauge steel housing in 3' and 4' sections rRigid U-shaped, double-formed trim with 3/8" regress soft-lit edge rIndividual or continuous run applications r Several shielding options available 6-3/8" [162mm] 81 ORDERING INFORMATION SAMPLE NUMBER: 81R-2T5-ETG-4D-1EB-SI-S22 Series Mounting Number of Lamps (Not Included) Lamp Type Ceiling Type Run Lenth 1 Voltage 2 Ballast Switching Options 81=Exposed T-grid Ceiling R=Recessed 1=1 Lamp 2=2 Lamps T5=T5 T5HO=T5HO T8=T8 ETG=15/16" Exposed T-grid Overall Nominal Run Length __ ft. 1=120V 2=277V 3=347V DB=Dimming Ballast EB=Electronic Ballast (Standard) DU=Double Switching SI=Single Switching Emergency Fusing Shielding Options EM=Emergency Pack (Consult Factory) GLR=GLR GMF=GMF S22=White Acrylic Diffuser S58=KSH-12 Acrylic Lens S72=Bold Baffle S79=Parabolic Baffle NOTES: 1. Available in 3' and 4' individual fixture lengths. 2. Not all options available. Please consult your Cooper Lighting Representative for availability. MOUNTING INFORMATION 48" [1219mm] 48" [1219mm] SHIELDING OPTIONS S58 Acrylic Lens S72 Bold Baffle NEO-RAY S22 Acrylic Diffuser S79 Parabolic Baffle Specifications and dimensions subject to change without notice. Consult your Cooper Lighting Representative or visit www.cooperlighting.com for available options, accessories and ordering information. Cooper Lighting by Eaton | Product Selection Guide | Sixth Edition | www.cooperlighting.com 9-28 RECESSED LINEAR DIRECT FEATURES r Direct light distribution r Recessed fixture for Sheetrock® ceilings r Die-formed 20-gauge steel housing in 3', 4', 6' and 8' sections r Individual or continuous run applications r Several shielding options available r Optional 90° corners r Dimming and emergency options 6" [153mm] 6-1/4" [159mm] Compliances may not apply to all product configurations. Please consult the product spec sheet for compliance details. COMPLIANCES: UL/cUL Listed - Damp Location, ARRA Compliant, NYC Code Compliant 6-1/4" [159mm] Ceiling opening 7" [178mm] 82 NOTE: Need to specify: Individual Run=Grid between fixtures, or Continuous Run=No Grid between fixtures. Continuous run fixtures cannot be installed as individuals, and individual fixtures cannot be combined into continuous runs. ORDERING INFORMATIONΔ SAMPLE NUMBER: 82R-1T8-SR-20'-1EB-SI-S22 Series Mounting Number of Lamps (Not Included) Lamp Type Ceiling Type Run Length Voltage 1 Ballast Switching Options 82=Sheetrock® Ceiling R=Recessed 1=1 Lamp 2=2 Lamps T5=T5 T5HO=T5HO T8=T8 SR=Sheetrock® (Flanged) Overall Nominal Run Length __ ft. 1=120V 2=277V 3=347V DB=Dimming Ballast EB=Electronic Ballast (Standard) DU=Double Switching SI=Single Switching Emergency Fusing Shielding Options EM=Emergency Pack (Consult Factory) GLR=GLR GMF=GMF S22=White Acrylic Diffuser S58=KSH-12 Acrylic Lens S72=Bold Baffle S79=Parabolic Baffle NOTES: Δ Individual fixtures cannot be combined into runs. availability. Δ SN82 option for compatibility with all 6 inch on-center ceiling systems. 1. Not all options available. Please consult your Cooper Lighting Representative for NEO-RAY SHIELDING OPTIONS S58 Acrylic Lens S72 Bold Baffle S79 Parabolic Baffle 90° Mitered Baffle Specifications and dimensions subject to change without notice. Consult your Cooper Lighting Representative or visit www.cooperlighting.com for available options, accessories and ordering information. 9-29 Cooper Lighting by Eaton | Product Selection Guide | Sixth Edition | www.cooperlighting.com Tie wires (not supplied by Neo-Ray) 5" [127mm] RECESSED DIRECT-AMBIENT FEATURES rDirect–ambient light distribution r 20-gauge steel housing in a 2' x 4' configuration rRecessed mounting for all ceiling applications rHigh efficiency r Numerous shielding options rBaked on low gloss, white, powder-coat finish rUL and CUL certified 24" [610mm] Compliances may not apply to all product configurations. Please consult the product spec sheet for compliance details. COMPLIANCES: UL/cUL Listed - Damp Location, ARRA Compliant, NYC Code Compliant SYMBIO 294 ORDERING INFORMATION SAMPLE NUMBER: 294R-3T5-SR-1EB-SI-S17 Series Options 1 Mounting Number of Lamps (Not Included) Lamp Type Ceiling Type Voltage 2 Ballast Switching Options 294=Symbio 2' x 4' A=Air Return C=Chicago Plenum T=Tannenbaum Reflector R=Recessed 1=1 Lamp 2=2 Lamps 3=3 Lamps T5=T5 T5HO=T5HO T8=T8 ETG=15/16" Exposed T-grid FSR=Sheetrock® (Flangeless) FTG=9/16" Exposed T-grid SR=Sheetrock® (Flanged) STG=Slot T-grid 1=120V 2=277V 3=347V DB=Dimming Ballast EB=Electronic Ballast (Standard) DU=Double Switching SI=Single Switching Emergency Shielding Options EM=Emergency Pack (Consult Factory) S17=Perforated Baffle S17A=Perforated Baffle with Acrylic Overlay 3 S17B=Translucent Acrylic Blades S17C=Translucent Acrylic Blades with Acrylic Overlay 3 S17F=Tannenbaum Blades S17G=Tannenbaum Blades with Acrylic Overlay 3 NOTES: 1. Can be left blank or more than one option may be available, consult factory. 2. Not all options available. Please consult your Cooper Lighting Representative for availability. 3. Overlay not available with 3T5HO lamping. MOUNTING INFORMATION ETG Exposed T-Grid STG Slot T-Grid SR Sheetrock NEO-RAY Specifications and dimensions subject to change without notice. Consult your Cooper Lighting Representative or visit www.cooperlighting.com for available options, accessories and ordering information. Cooper Lighting by Eaton | Product Selection Guide | Sixth Edition | www.cooperlighting.com 9-30 RECESSED DIRECT-AMBIENT FEATURES r Direct–ambient light distribution r 20-gauge steel housing in a 2' x 2' configuration r Recessed mounting for all ceiling applications r High efficiency r Numerous shielding options r Baked on low gloss, white, powder-coat finish r UL and CUL certified Tie wires (not supplied by Neo-Ray) 5" [127mm] 24" [610mm] Compliances may not apply to all product configurations. Please consult the product spec sheet for compliance details. COMPLIANCES: UL/cUL Listed - Damp Location, ARRA Compliant, NYC Code Compliant ORDERING INFORMATION SAMPLE NUMBER: 292R-2T5-STG-1EB-SI-S17A Series Options 1 Mounting Number of Lamps (Not Included) Lamp Type Ceiling Type Voltage 3 Ballast Switching Options 292=Symbio 2' x 2' A=Air Return C=Chicago Plenum T=Tannenbaum Reflector R=Recessed 1=1 Lamp 2=2 Lamps 3=3 Lamps BX40W =BX40W 2 BX50W=BX50W 2 T5=T5 T5HO=T5HO ETG=15/16" Exposed T-grid FSR=Sheetrock® (Flangeless) FTG=9/16" Exposed T-grid SR=Sheetrock® (Flanged) STG=Slot T-grid 1=120V 2=277V 3=347V DB=Dimming Ballast EB=Electronic Ballast (Standard) DU=Double Switching SI=Single Switching Emergency Shielding Options EM=Emergency Pack (Consult Factory) S17=Perforated Baffle S17A=Perforated Baffle with Acrylic Overlay 4 S17B=Translucent Acrylic Blades S17C=Translucent Acrylic Blades with Acrylic Overlay 4 S17F=Tannenbaum Blades S17G=Tannenbaum Blades with Acrylic Overlay 4 NOTES: 1. Can be left blank or more than one option may be available, consult factory. 2. Fixture available with only one BIAX lamp in cross section. 3. Not all options available. Please consult your Cooper Lighting Representative for availability. 4. Overlay not available with 3T5HO lamping. MOUNTING INFORMATION STG Slot T-Grid SR Sheetrock NEO-RAY ETG Exposed T-Grid Specifications and dimensions subject to change without notice. Consult your Cooper Lighting Representative or visit www.cooperlighting.com for available options, accessories and ordering information. 9-31 Cooper Lighting by Eaton | Product Selection Guide | Sixth Edition | www.cooperlighting.com 5" [127mm] RECESSED DIRECT-AMBIENT FEATURES rDirect–ambient light distribution r20-gauge steel housing in a 1' x 4' configuration r Recessed mounting for all ceiling applications rHigh efficiency rNumerous shielding options r Baked on low gloss, white, powder-coat finish rUL and CUL certified 12" [305mm] Compliances may not apply to all product configurations. Please consult the product spec sheet for compliance details. COMPLIANCES: UL/cUL Listed - Damp Location, ARRA Compliant, NYC Code Compliant SYMBIO 194 ORDERING INFORMATION SAMPLE NUMBER: 194R-2T5-STG-1EB-SI-S17B Series Options 1 Mounting Number of Lamps (Not Included) Lamp Type Ceiling Type Voltage 2 Ballast 194=Symbio A=Air Return C=Chicago Plenum T=Tannenbaum Reflector R=Recessed 1=1 Lamp 2=2 Lamps T5=T5 T5HO=T5HO T8=T8 ETG=15/16" Exposed T-grid FSR=Sheetrock® (Flangeless) FTG=9/16" Exposed T-grid SR=Sheetrock® (Flanged) STG=Slot T-grid 1=120V 2=277V 3=347V DB=Dimming Ballast EB=Electronic Ballast (Standard) Switching Options Emergency Shielding Options DU=Double Switching SI=Single Switching EM=Emergency Pack (Consult Factory) S17=Perforated Baffle S17A=Perforated Baffle with Acrylic Overlay S17B=Translucent Acrylic Blades S17C=Translucent Acrylic Blades with Acrylic Overlay S17F=Tannenbaum Blades S17G=Tannenbaum Blades with Acrylic Overlay NOTES: 1. Can be left blank or more than one option may be available, consult factory. 2. Not all options available. Please consult your Cooper Lighting Representative for availability. MOUNTING INFORMATION ETG Exposed T-Grid STG Slot T-Grid SR Sheetrock STANDARD LUMINAIRE PLAN 12" x 48" (305mm x 1219mm) Nominal (1 or 2 lamps) NEO-RAY Specifications and dimensions subject to change without notice. Consult your Cooper Lighting Representative or visit www.cooperlighting.com for available options, accessories and ordering information. Cooper Lighting by Eaton | Product Selection Guide | Sixth Edition | www.cooperlighting.com 9-32 RECESSED DIRECT-AMBIENT FEATURES r Direct–ambient recessed lighting r Super high-efficiency r Multiple center panel diffuser options r 2' x 2', 2' x 4' r Low profile 3-3/4" high steel housing r Fully illuminated, all acrylic diffusers with bold regressed trim r Easy ballast and lamp maintenance r UL and CUL certified Support wire (by others) 22-1/4" [556mm] 3-3/4" [95mm] 6-1/2" [165mm] 23-3/4" [594mm for metric version] Compliances may not apply to all product configurations. Please consult the product spec sheet for compliance details. 24" (Grid center-to-center) [600mm for metric version] COMPLIANCES: UL/cUL Listed - Damp Location, ARRA Compliant, NYC Code Compliant LUMINOUS HE 282, 284 ORDERING INFORMATION SAMPLE NUMBER: 284R-2T5HO-FTG-UEB-SI-95N Series Options Mounting Number of Lamps (Not Included) Lamp Type Ceiling Type Voltage Ballast 282=2x2 282M=600x600 284=2x4 284M=600x1200 A=Air Return C=Chicago R=Recessed 1=1 Lamp 2=2 Lamps 3=3 Lamps T5=T5 T5HO=T5HO T8=T8 ESTG=15/16" Grid, 9/16" Slot T-grid FTG=9/16" Flush Grid SR=Sheetrock® 1 1=120V 2=277V 3=347V U=Universal (120-277V) DB=Dimming Ballast 2 EB=Electronic Ballast (Standard) Switching Options Emergency Center Shielding Options DU=Dual Switching SI=Single Switching EC=Emergency Circuit EM=Emergency Pack (Consult Factory) 95B=Textured Blue Diffuser 3 95HT=High Transmission Diffuser 95N=Opal Satin Diffuser 95R=Opal Satin Diffuser with Round Perforated Pattern 95RE=Opal Satin Diffuser with Rectangular Perforated Pattern NOTES: 1. For Sheetrock® specify Metalux DFW series drywall frame-in kit, ordered separately from Metalux. For 2' x 2' order Metalux part #DF-22W-U; for 2' x 4' order part#DF-24W-U. 2. For dimming, specify ballast option. 3. Consult factory for additional colors or textures. MOUNTING INFORMATION ESTG 15/16" Flush T-Grid ESTG 9/16" Slot T-Grid Flange resets on top Of tee for metric ESTG 9/16" Tegular grid FTG 9/16" Flush T-Grid SR Sheetrock NEO-RAY CENTER SHIELDING OPTIONS 95B Textured Blue Diffuser 95HT High Transmission (87%) Diffuser 95N Opal Satin (74%) Diffuser 95R Opal Satin Diffuser with Round Perforated Pattern 95RE Opal Satin Diffuser with Rectangular Perforated Pattern Specifications and dimensions subject to change without notice. Consult your Cooper Lighting Representative or visit www.cooperlighting.com for available options, accessories and ordering information. 9-33 Cooper Lighting by Eaton | Product Selection Guide | Sixth Edition | www.cooperlighting.com Tie wires (not supplied by Neo-Ray) 5" [127mm] RECESSED DIRECT-AMBIENT FEATURES rDirect–ambient light distribution rBroad, ambient light distribution reduces fixture quantity and load r Four-inch center basket increases efficiency and reduces visual mass rHigh efficiency r20-gauge housing designed for meticulous fit with all ceiling types r Optional center slots basket for a fresh visual appearance rDimming and emergency options rUL and CUL certified 24" [610mm] Compliances may not apply to all product configurations. Please consult the product spec sheet for compliance details. COMPLIANCES: UL/cUL Listed - Damp Location, ARRA Compliant, NYC Code Compliant FENESTRA 272, 274 ORDERING INFORMATION SAMPLE NUMBER: 274R-2T5-ETG-1EB-SI Series Options 1 Mounting Number of Lamps (Not Included) Lamp Type Ceiling Type Voltage 3 Ballast Switching Options 272=2' x 2' 274=2' x 4' A=Air Return C=Chicago Plenum T=Tannenbaum Reflector R=Recessed 1=1 Lamp 2=2 Lamps BX40W =BX40W 2 BX50W=BX50W 2 T5=T5 T5HO=T5HO ETG=15/16" Exposed T-grid FTG=9/16" Exposed T-grid SR=Sheetrock® (Flanged) STG=Slot T-grid 1=120V 2=277V 3=347V DB=Dimming Ballast EB=Electronic Ballast (Standard) DU=Double Switching SI=Single Switching Emergency EM=Emergency Pack (Consult Factory) NOTES: 1. Can be left blank or more than one option may be available, consult factory. 2. Fixture available with only one BIAX lamp in cross section. 3. Not all options available. Please consult your Cooper Lighting Representative for availability. MOUNTING INFORMATION Leveing lug assembly 2-3/4" ETG Standard lay-in ceiling (grid lay-in) STG Screw slot ceiling (slot-t) Black iron (not by Neo-Ray) SR Sheetrock ceiling (flange) FTG Standard lay-in ceiling (grid lay-in) STANDARD LUMINAIRE PLAN 24" x 48" (610mm x 1219mm) (1 or 2 lamps) 24" x 24" (610mm x 610mm) (1 or 2 lamps) 272 274 REFLECTOR OPTIONS NEO-RAY Tannenbaum Optional Rippled Aluminum Reflector Specifications and dimensions subject to change without notice. Consult your Cooper Lighting Representative or visit www.cooperlighting.com for available options, accessories and ordering information. Cooper Lighting by Eaton | Product Selection Guide | Sixth Edition | www.cooperlighting.com 9-34 RECESSED DIRECT-AMBIENT FEATURES r Direct–ambient light distribution r Fully enclosed, easy-to-clean acrylic diffuser r 20-gauge steel housing accommodates all ceiling trims r Highly efficient diffuser offers low glare and broad distribution r Three levels of lighting for complete control r Optional dual T8/T5HO lamping with dual switching for exam purposes r Dimming and emergency options r UL and CUL certified Tie wires (not supplied by Neo-Ray) 4-5/8" [118mm] 7-5/16" [186mm] Shield width 1-9/16" [40mm] Compliances may not apply to all product configurations. Please consult the product spec sheet for compliance details. COMPLIANCES: UL/cUL Listed - Damp Location, ARRA Compliant, NYC Code Compliant 23-13/32" [595mm] x 47-13/32" [1204mm] Fixture size 24" [610mm] x 48" [1219mm] Grid center-to-center FENESTRA 262, 264 ORDERING INFORMATION SAMPLE NUMBER: 264R-2T8-ETG-1EB-SI Series Options 1 Mounting Number of Lamps (Not Included) Lamp Type Ceiling Type Voltage Ballast Switching Options 262=2' X 2' 264=2' X 4' A=Air Return 2 C=Chicago Plenum T=Tannenbaum R=Recessed 1=1 Lamp 2=2 Lamps 3=3 Lamps T5=T5 T5HO=T5HO T8=T8 ETG=Exposed T-grid STG=Slot T-grid 1=120V 2=277V 3=347V DB=Dimming Ballast EB=Electronic Ballast (Standard) DU=Double Switching SI=Single Switching Emergency EM=Emergency Pack (Consult Factory) NOTES: 1. Can be left blank or more than one option may be available, consult factory. 2. Air Return not available for Slot T-grid. MOUNTING INFORMATION Leveing lug assembly 2-3/4" ETG Standard lay-in ceiling (grid lay-in) STG Screw slot ceiling (slot-t) Black iron (not by Neo-Ray) SR Sheetrock ceiling (flange) FTG Standard lay-in ceiling (grid lay-in) NEO-RAY REFLECTOR OPTIONS Tannenbaum Optional Rippled Aluminum Reflector Specifications and dimensions subject to change without notice. Consult your Cooper Lighting Representative or visit www.cooperlighting.com for available options, accessories and ordering information. 9-35 Cooper Lighting by Eaton | Product Selection Guide | Sixth Edition | www.cooperlighting.com Tie wires (not supplied by Neo-Ray) 3" [76mm] 1-31/32" [50mm] 24" [610mm] RECESSED DIRECT-AMBIENT FEATURES r Direct–ambient light distribution rNarrow 4-inch diameter drop center basket design r 20-gauge steel housing fits ceiling types with minimal trim exposure r Low direct glare illumination rAir return and Chicago Plenum options available r Tannenbaum ribbed aluminum reflector option r UL and CUL certified Compliances may not apply to all product configurations. Please consult the product spec sheet for compliance details. COMPLIANCES: UL/cUL Listed - Damp Location, ARRA Compliant, NYC Code Compliant FENESTRA 252, 254 ORDERING INFORMATION SAMPLE NUMBER: 252R-1T5-ETG-1EB-SI Series Options 1 Mounting Number of Lamps (Not Included) Lamp Type Ceiling Type Voltage 3 Ballast Switching Options 252=2' x 2' 254=2' x 4' A=Air Return C=Chicago Plenum T=Tannenbaum Reflector R=Recessed 1=1 Lamp 2=2 Lamps BX40W =BX40W 2 BX50W=BX50W 2 T5=T5 T5HO=T5HO ETG=15/16" Exposed T-grid FTG=9/16" Exposed T-grid SR=Sheetrock® (Flanged) STG=Slot T-grid 1=120V 2=277V 3=347V DB=Dimming Ballast EB=Electronic Ballast (Standard) DU=Double Switching SI=Single Switching Emergency EM=Emergency Pack (Consult Factory) NOTES: 1. Can be left blank or more than one option may be available, consult factory. 2. Available with 1 lamp only. 3. Not all options available. Please consult your Cooper Lighting Representative for availability. MOUNTING INFORMATION Leveling lug assembly 2-3/4" ETG Standard lay-in ceiling (grid lay-in) STG Screw slot ceiling (slot-t) Black iron (not by Neo-Ray) SR Sheetrock ceiling (flange) FTG Standard lay-in ceiling (grid lay-in) REFLECTOR OPTIONS NEO-RAY Tannenbaum Optional Rippled Aluminum Reflector Specifications and dimensions subject to change without notice. Consult your Cooper Lighting Representative or visit www.cooperlighting.com for available options, accessories and ordering information. Cooper Lighting by Eaton | Product Selection Guide | Sixth Edition | www.cooperlighting.com 9-36 RECESSED DIRECT-AMBIENT FEATURES r Direct–ambient light distribution r Flush-center basket design r 20-gauge steel housing fits ceiling types with minimal trim exposure r Center slot detailing option available on the basket r Air return and Chicago Plenum options available r Tannenbaum ribbed aluminum reflector option r UL and CUL certified Tie wires (not supplies by Neo-Ray) 5-31/32" [152mm] 23-19/64" [592mm] 24" [610mm] Compliances may not apply to all product configurations. Please consult the product spec sheet for compliance details. COMPLIANCES: UL/cUL Listed - Damp Location, ARRA Compliant, NYC Code Compliant FENESTRA 242, 244 ORDERING INFORMATION SAMPLE NUMBER: 244R-2T5-ETG-1EB-SI Series Options 1 Mounting Number of Lamps (Not Included) Lamp Type Ceiling Type Voltage 2 Ballast Switching Options 242=2' x 2' 244=2' x 4' A=Air Return C=Chicago Plenum T=Tannenbaum Reflector R=Recessed 1=1 Lamp 2=2 Lamps 3=3 Lamps BX40W=BX40W BX50W=BX50W T5=T5 T5HO=T5HO T8=T8 ETG=15/16" Exposed T-grid FTG=9/16" Exposed T-grid SR=Sheetrock® (Flanged) STG=Slot T-grid 1=120V 2=277V 3=347V DB=Dimming Ballast EB=Electronic Ballast (Standard) DU=Double Switching SI=Single Switching Perforation Emergency SCS=Center Slots SP=Slotted EM=Emergency Pack (Consult Factory) NOTES: 1. Can be left blank or more than one option may be available, consult factory. 2. Not all options available. Please consult your Cooper Lighting Representative for availability. MOUNTING INFORMATION Leveling lug assembly 2-3/4" Black iron (not by Neo-Ray) ETG Standard lay-in ceiling (grid lay-in) STG Screw slot ceiling (slot-t) SR Sheetrock ceiling (flange) FTG Standard lay-in ceiling (grid lay-in) NEO-RAY REFLECTOR OPTIONS Tannenbaum Optional Rippled Aluminum Reflector Specifications and dimensions subject to change without notice. Consult your Cooper Lighting Representative or visit www.cooperlighting.com for available options, accessories and ordering information. 9-37 Cooper Lighting by Eaton | Product Selection Guide | Sixth Edition | www.cooperlighting.com 5" [127mm] Louver Diffuser Reflector Louver blades 3-1/8" [79mm] RECESSED DIRECT-AMBIENT 232/234 ISL with 3 T8 FEATURES rDirect–ambient light distribution rIsolated downlight for AV presentations r Flush-center louver and basket design r20-gauge steel housing fits ceiling types with minimal trim exposure rLow glare direct illumination r Air return and Chicago Plenum options available rTannenbaum ribbed aluminum reflector option rUL and CUL certified 12-3/4" [324mm] 23-1/16" [586mm] 24" [610mm] Compliances may not apply to all product configurations. Please consult the product spec sheet for compliance details. COMPLIANCES: UL/cUL Listed - Damp Location, ARRA Compliant, NYC Code Compliant FENESTRA 232 ISL, 234 ISL ORDERING INFORMATION SAMPLE NUMBER: 232-ISL-R-3T8-ETG-1EB-DU Series Options Mounting Number of Lamps (Not Included) Lamp Type Ceiling Type Voltage 1 Ballast Switching Options 232=2' x 2' 234=2' x 4' ISL=Isolated Downlight R=Recessed 3=3 Lamps BX40W=BX40W BX50W=BX50W T5=T5 T5HO=T5HO T8=T8 ETG=Exposed T-grid SR=Sheetrock® (Flanged) STG=Screw Slot T-grid 1=120V 2=277V 3=347V DB=Dimming Ballast EB=Electronic Ballast (Standard) DU=Dual Switching Emergency Louver Options EM=Emergency Pack (Consult Factory) CB=Clear Acrylic Blades SF=Frosted Acrylic Blades SIB=Blue Acrylic Blades NOTES: 1. Not all options available. Please consult your Cooper Lighting Representative for availability. MOUNTING INFORMATION Leveling lug assembly 2-3/4" ETG Standard lay-in ceiling (grid lay-in) STG Screw slot ceiling (slot-t) Black iron (not by Neo-Ray) SR Sheetrock ceiling (flange) REFLECTOR OPTIONS NEO-RAY Tannenbaum Optional Rippled Aluminum Reflector Specifications and dimensions subject to change without notice. Consult your Cooper Lighting Representative or visit www.cooperlighting.com for available options, accessories and ordering information. Cooper Lighting by Eaton | Product Selection Guide | Sixth Edition | www.cooperlighting.com 9-38 RECESSED DIRECT-AMBIENT FEATURES r Direct–ambient light distribution r Flush-center louver and basket design r 20-gauge steel housing fits ceiling types with minimal trim exposure r Low-glare direct illumination r Air return and Chicago Plenum options available r Tannenbaum ribbed aluminum reflector option r Dimming and emergency options r UL and CUL certified Tie wires (not supplied by Neo-Ray) 5" [127mm] 3-1/8" [79mm] 12-3/4" [324mm] 23-1/16" [586mm] 24" [610mm] Compliances may not apply to all product configurations. Please consult the product spec sheet for compliance details. COMPLIANCES: UL/cUL Listed - Damp Location, ARRA Compliant, NYC Code Compliant FENESTRA 232, 234 ORDERING INFORMATION SAMPLE NUMBER: 232R-2T5-ETG-1EB-SI Series Options 1 Mounting Number of Lamps (Not Included) Lamp Type Ceiling Type Voltage 3 Ballast Switching Options 232=2' x 2' 234=2' x 4' A=Air Return 2 T=Tannenbaum R=Recessed 2=2 Lamps 3=3 Lamps BX40W=BX40W BX50W=BX50W T5=T5 T5HO=T5HO T8=T8 ETG=15/16" Exposed T-grid FTG=9/16" Exposed T-grid SR=Sheetrock® (Flanged) STG=Slot T-grid 1=120V 2=277V 3=347V DB=Dimming Ballast EB=Electronic Ballast (Standard) DU=Double Switching SI=Single Switching Emergency Louver Options EM=Emergency Pack (Consult Factory) SF=Frosted Baffle SIB=Blue Ice Baffle SLS=Light Slots Baffle NOTES: 1. Can be left blank or more than one option may be available, consult factory. 2. Air Return not available for Slot T-grid. 3. Not all options available. Please consult your Cooper Lighting Representative for availability. MOUNTING INFORMATION Leveling lug assembly 2-3/4" ETG Standard lay-in ceiling (grid lay-in) STG Screw slot ceiling (slot-t) Black iron (not by Neo-Ray) SR Sheetrock ceiling (flange) FTG Standard lay-in ceiling (grid lay-in) NEO-RAY REFLECTOR OPTIONS Tannenbaum Optional Rippled Aluminum Reflector Specifications and dimensions subject to change without notice. Consult your Cooper Lighting Representative or visit www.cooperlighting.com for available options, accessories and ordering information. 9-39 Cooper Lighting by Eaton | Product Selection Guide | Sixth Edition | www.cooperlighting.com Tie wires (not supplied by Neo-Ray) 5" [127mm] RECESSED DIRECT-AMBIENT FEATURES rDirect–ambient light distribution rFlush center-split basket design r Recessed mounting for all ceiling applications rLow-glare direct-indirect illumination rSturdy 2' x 2' or 2' x 4' 20-gauge steel configurations r Air return and Chicago Plenum options available rTannenbaum ribbed aluminum reflector option rUL and CUL certified 3-1/8" [79mm] 12-3/4" [324mm] 23-1/16" [586mm] 24" [610mm] Compliances may not apply to all product configurations. Please consult the product spec sheet for compliance details. COMPLIANCES: UL/cUL Listed - Damp Location, ARRA Compliant, NYC Code Compliant FENESTRA 222, 224 ORDERING INFORMATION SAMPLE NUMBER: 222R-2T5-ETG-1EB-SI Series Options 1 Mounting Number of Lamps (Not Included) Lamp Type Ceiling Type Voltage 2 Ballast Switching Options 222=2' x 2' 224=2' x 4' A=Air Return C=Chicago Plenum T=Tannenbaum Reflector R=Recessed 2=2 Lamps BX40W=BX40W BX50W=BX50W T5=T5 T5HO=T5HO T8=T8 ETG=15/16" Exposed T-grid FTG=9/16" Exposed T-grid SR=Sheetrock® (Flanged) STG=Slot T-grid 1=120V 2=277V 3=347V DB=Dimming Ballast EB=Electronic Ballast (Standard) DU=Double Switching SI=Single Switching Emergency EM=Emergency Pack (Consult Factory) NOTES: 1. Can be left blank or more than one option may be available, consult factory. 2. Not all options available. Please consult your Cooper Lighting Representative for availability. MOUNTING INFORMATION Leveling lug assembly 2-3/4" Black iron (not by Neo-Ray) ETG Standard lay-in ceiling (grid lay-in) STG Screw slot ceiling (slot-t) SR Sheetrock ceiling (flange) FTG Standard lay-in ceiling (grid lay-in) REFLECTOR OPTIONS NEO-RAY Tannenbaum Optional Rippled Aluminum Reflector Specifications and dimensions subject to change without notice. Consult your Cooper Lighting Representative or visit www.cooperlighting.com for available options, accessories and ordering information. Cooper Lighting by Eaton | Product Selection Guide | Sixth Edition | www.cooperlighting.com 9-40 RECESSED FEATURES r Direct–ambient light distribution r Flush-side basket design r Recessed mounting for all ceiling applications r Sturdy 2' x 2' or 2' x 4' 20-gauge steel configurations r Perforated metal shielding panels backed by a white acrylic diffuser r Dimming and emergency options r UL and CUL certified Tie wires (not supplied by Neo-Ray) 6-1/4" [159mm] 24" [610mm] Compliances may not apply to all product configurations. Please consult the product spec sheet for compliance details. COMPLIANCES: UL/cUL Listed - Damp Location, ARRA Compliant, NYC Code Compliant FENESTRA 202, 204 ORDERING INFORMATION SAMPLE NUMBER: 202R-2T5-ETG-1EB-SI Series Options 1 Mounting Number of Lamps (Not Included) Lamp Type Ceiling Type Voltage 3 Ballast 202=2' x 2' 204=2' x 4' A=Air Return 2 C=Chicago Plenum T=Tannenbaum Reflector R=Recessed 2=2 Lamps BX40W=BX40W BX50W=BX50W T5=T5 T5HO=T5HO T8=T8 ETG=15/16" Exposed T-grid FTG=9/16" Exposed T-grid SR=Sheetrock® (Flanged) STG=Slot T-grid 1=120V 2=277V 3=347V DB=Dimming Ballast EB=Electronic Ballast (Standard) Switching Options Emergency DU=Double Switching SI=Single Switching EM=Emergency Pack (Consult Factory) NOTES: 1. Can be left blank or more than one option may be available, consult factory. 2. Air Return not available for Slot T-grid. 3. Not all options available. Please consult your Cooper Lighting Representative for availability. MOUNTING INFORMATION STG Slot T-Grid SR Sheetrock NEO-RAY ETG Exposed T-Grid Specifications and dimensions subject to change without notice. Consult your Cooper Lighting Representative or visit www.cooperlighting.com for available options, accessories and ordering information. 9-41 Cooper Lighting by Eaton | Product Selection Guide | Sixth Edition | www.cooperlighting.com Tie wires (not supplied by Neo-Ray) RECESSED DIRECT-AMBIENT FEATURES rDirect–ambient light distribution rNarrow center diffuser increases efficiency and reduces visual mass r 20-gauge 1' x 4' steel housing designed for fit with all ceiling types rAir return and Chicago Plenum options available rTannenbaum ribbed aluminum reflector option r Dimming and emergency options rUL and CUL certified 5" [127mm] Compliances may not apply to all product configurations. Please consult the product spec sheet for compliance details. COMPLIANCES: UL/cUL Listed - Damp Location, ARRA Compliant, NYC Code Compliant 12" [305mm] FENESTRA 174 ORDERING INFORMATION SAMPLE NUMBER: 174R-2T5-ETG-1EB-SI Series Options 1 Mounting Number of Lamps (Not Included) Lamp Type Ceiling Type Voltage 2 Ballast Switching Options 174=1' x 4' A=Air Return C=Chicago Plenum T=Tannenbaum Reflector R=Recessed 1=1 Lamp 2=2 Lamps T5=T5 T5HO=T5HO ETG=15/16" Exposed T-grid FTG=9/16" Exposed T-grid SR=Sheetrock® (Flanged) STG=Slot T-grid 1=120V 2=277V 3=347V DB=Dimming Ballast EB=Electronic Ballast (Standard) DU=Double Switching SI=Single Switching Emergency EM=Emergency Pack (Consult Factory) NOTES: 1. Can be left blank or more than one option may be available, consult factory. 2. Not all options available. Please consult your Cooper Lighting Representative for availability. MOUNTING INFORMATION Leveling lug assembly 2-3/4" ETG Standard lay-in ceiling (grid lay-in) STG Screw slot ceiling (slot-t) Black iron (not by Neo-Ray) SR Sheetrock ceiling (flange) FTG Standard lay-in ceiling (grid lay-in) REFLECTOR OPTIONS NEO-RAY Tannenbaum Optional Rippled Aluminum Reflector Specifications and dimensions subject to change without notice. Consult your Cooper Lighting Representative or visit www.cooperlighting.com for available options, accessories and ordering information. Cooper Lighting by Eaton | Product Selection Guide | Sixth Edition | www.cooperlighting.com 9-42 RECESSED DIRECT-AMBIENT FEATURES r Direct–ambient light distribution r Drop center basket design with a narrow 4-inch diameter perf basket r 20-gauge 1' x 4' steel housing fits ceiling types with minimal trim r Low direct-glare illumination r Air return and Chicago Plenum options available r Tannenbaum ribbed aluminum reflector option r UL and CUL certified Tie wires (not supplied by Neo-Ray) 3" [76mm] 1-31/32" [50mm] Compliances may not apply to all product configurations. Please consult the product spec sheet for compliance details. 12" [305mm] COMPLIANCES: UL/cUL Listed - Damp Location, ARRA Compliant, NYC Code Compliant FENESTRA 154 ORDERING INFORMATION SAMPLE NUMBER: 154R-1T5-ETG-1EB-SI Series Options 1 Mounting Number of Lamps (Not Included) Lamp Type Ceiling Type Voltage 3 Ballast Switching Options 154=1' x 4' A=Air Return C=Chicago Plenum T=Tannenbaum Reflector R=Recessed 1=1 Lamp 2=2 Lamps BX40W=BX40W 2 BX50W=BX50W 2 T5=T5 T5HO=T5HO T8=T8 ETG=15/16" Exposed T-grid FTG=9/16" Exposed T-grid SR=Sheetrock® (Flanged) STG=Slot T-grid 1=120V 2=277V 3=347V DB=Dimming Ballast EB=Electronic Ballast (Standard) DU=Double Switching SI=Single Switching Emergency EM=Emergency Pack (Consult Factory) NOTES: 1. Can be left blank or more than one option may be available, consult factory. 2. Available with 1 lamp only. 3. Not all options available. Please consult your Cooper Lighting Representative for availability. MOUNTING INFORMATION Leveling lug assembly 2-3/4" ETG Standard lay-in ceiling (grid lay-in) STG Screw slot ceiling (slot-t) Black iron (not by Neo-Ray) SR Sheetrock ceiling (flange) FTG Standard lay-in ceiling (grid lay-in) NEO-RAY REFLECTOR OPTIONS Tannenbaum Optional Rippled Aluminum Reflector Specifications and dimensions subject to change without notice. Consult your Cooper Lighting Representative or visit www.cooperlighting.com for available options, accessories and ordering information. 9-43 Cooper Lighting by Eaton | Product Selection Guide | Sixth Edition | www.cooperlighting.com Tie wires (not supplied by Neo-Ray) RECESSED DIRECT-AMBIENT FEATURES r Direct–ambient light distribution r Flush-center basket design rRecessed mounting for all ceiling applications r Low-glare direct-indirect illumination r Sturdy 1' x 2' or 1' x 4' 20-gauge steel configurations rAir return and Chicago Plenum options available r Tannenbaum ribbed aluminum reflector option 5-9/32" [134mm] Compliances may not apply to all product configurations. Please consult the product spec sheet for compliance details. COMPLIANCES: UL/cUL Listed - Damp Location, ARRA Compliant, NYC Code Compliant 11-23/64" [289mm] 12" [305mm] FENESTRA 142, 144 ORDERING INFORMATION SAMPLE NUMBER: 144R-1T5-ETG-1EB-SI Series Options 1 Mounting Number of Lamps (Not Included) Lamp Type Ceiling Type Voltage 3 Ballast Switching Options 142=1' x 2' 144=1' x 4' A=Air Return C=Chicago Plenum T=Tannenbaum Reflector R=Recessed 1=1 Lamp 2=2 Lamps BX40W=BX40W 2 BX50W=BX50W 2 T5=T5 T5HO=T5HO T8=T8 ETG=15/16" Exposed T-grid SR=Sheetrock® (Flanged) STG=Slot T-grid 1=120V 2=277V 3=347V DB=Dimming Ballast EB=Electronic Ballast (Standard) DU=Double Switching SI=Single Switching Emergency EM=Emergency Pack (Consult Factory) NOTES: 1. Can be left blank or more than one option may be available, consult factory. 2. Available with 1 lamp only. 3. Not all options available. Please consult your Cooper Lighting Representative for availability. MOUNTING INFORMATION Leveling lug assembly 2-3/4" ETG Standard lay-in ceiling (grid lay-in) STG Screw slot ceiling (slot-t) Black iron (not by Neo-Ray) SR Sheetrock ceiling (flange) FTG Standard lay-in ceiling (grid lay-in) REFLECTOR OPTIONS NEO-RAY Tannenbaum Optional Rippled Aluminum Reflector Specifications and dimensions subject to change without notice. Consult your Cooper Lighting Representative or visit www.cooperlighting.com for available options, accessories and ordering information. Cooper Lighting by Eaton | Product Selection Guide | Sixth Edition | www.cooperlighting.com 9-44 RECESSED DIRECT-AMBIENT FEATURES r Direct–ambient light distribution r Recessed mounting for all ceiling applications r Durable, powder-coated paint finish r Sturdy 1' x 2' or 1' x 4' 20-gauge steel configurations r Perforated metal shielding panels backed by a white acrylic diffuser r Single lamp options include Biaxial, T5 or T5HO lamping r Dimming and emergency options r UL and CUL certified Tie wires (not supplied by Neo-Ray) 5" [127mm] 11-1/16" [281mm] Compliances may not apply to all product configurations. Please consult the product spec sheet for compliance details. 12" [305mm] COMPLIANCES: UL/cUL Listed - Damp Location, ARRA Compliant, NYC Code Compliant FENESTRA 112, 114 ORDERING INFORMATION SAMPLE NUMBER: 112R-1T5-ETG-1EB-SI Series Options 1 Mounting Number of Lamps (Not Included) Lamp Type Ceiling Type Voltage 2 Ballast Switching Options 112=1' x 2' 114=1' x 4' A=Air Return C=Chicago Plenum T=Tannenbaum Reflector R=Recessed 1=1 Lamp BX40W=BX40W BX50W=BX50W T5=T5 T5HO=T5HO ETG=15/16" Exposed T-grid FSR=Sheetrock® (Flangeless) FTG=9/16" Exposed T-grid SR=Sheetrock® (Flanged) STG=Slot T-grid 1=120V 2=277V 3=347V DB=Dimming Ballast EB=Electronic Ballast (Standard) SI=Single Switching Emergency EM=Emergency Pack (Consult Factory) NOTES: 1. Can be left blank or more than one option may be available, consult factory. 2. Not all options available. Please consult your Cooper Lighting Representative for availability. MOUNTING INFORMATION Leveling lug assembly 2-3/4" ETG Standard lay-in ceiling (grid lay-in) REFLECTOR OPTIONS STG Screw slot ceiling (slot-t) Black iron (not by Neo-Ray) SR Sheetrock ceiling (flange) FTG Standard lay-in ceiling (grid lay-in) STANDARD LUMINAIRE PLAN NEO-RAY 12" x 24" (305mm x 610mm) (1 lamp) 12" x 48" (305mm x 1219mm) (1 lamp) Tannenbaum Optional Rippled Aluminum Reflector Specifications and dimensions subject to change without notice. Consult your Cooper Lighting Representative or visit www.cooperlighting.com for available options, accessories and ordering information. 9-45 Cooper Lighting by Eaton | Product Selection Guide | Sixth Edition | www.cooperlighting.com 8-1/2" [216mm] RECESSED DIRECT FEATURES rDirect light distribution rDie-formed 20-gauge recessed steel housing r Extruded-aluminum 2" regressed trim with mitered corners rLuminous acrylic panel shielding rAvailable in several square and rectangular sizes up to 4' x 4' r Dimming and emergency options rUL and CUL certified 2" [51mm] 5-3/4" [146mm] Compliances may not apply to all product configurations. Please consult the product spec sheet for compliance details. COMPLIANCES: UL/cUL Listed - Damp Location, ARRA Compliant, NYC Code Compliant SERIES 7 ORDERING INFORMATIONΔ SAMPLE NUMBER: 7-448R-4T5-ETG-1EB-SI-S46 Series Fixture Size Mounting Number of Lamps (Not Included) Lamp Type Ceiling Type Voltage Ballast Switching Options 7=7 124=12"x24" 1 148=12"x48" 1 224=24"x24" 1 248=24"x48" 1 448=48"x48" 2 648=6"x48" 3 R=Recessed 1=1 Lamp 2=2 Lamps 3=3 Lamps 4=4 Lamps 6=6 Lamps T5=T5 T5HO=T5HO T8=T8 ETG=15/16" Exposed T-grid SR=Sheetrock® (Flanged) 1=120V 2=277V 3=347V DB=Dimming Ballast EB=Electronic Ballast (Standard) DU=Double Switching SI=Single Switching Emergency Fusing Shielding Options EM=Emergency Pack (Consult Factory) GLR=GLR GMF=GMF S46=Structural Acrylic NOTES: Δ Supplied as individual fixtures and not continuous runs. Must be installed before ceiling. 1. With one, two, or three lamps. 2. With three, four, or six lamps. 3. With one or two lamps. MOUNTING INFORMATION ETG Exposed T-Grid SPECIFICATION FEATURES 6" x 48" [152mm x 1219mm] 12" x 24" [305mm x 609.5mm] 12" x 48" [305mm x 1219mm] 24" x 24" [610mm x 610mm] 24" x 48" [610mm x 1219mm] 48" x 48" [1219mm x 1219mm] SR Sheetrock SHIELDING OPTIONS NEO-RAY S46 Structural Acrylic Specifications and dimensions subject to change without notice. Consult your Cooper Lighting Representative or visit www.cooperlighting.com for available options, accessories and ordering information. Cooper Lighting by Eaton | Product Selection Guide | Sixth Edition | www.cooperlighting.com 9-46 VIDEO CONFERENCE DIRECT FEATURES r Direct–asymmetric light distribution r Composite prismatic louver design for uniform vertical illumination r Precisely controlled light distribution prevents light spillage r 20-gauge steel housing fits ceiling types with minimal trim exposure r Available in 1' x 2', 1' x 4' and 2' x 2' individual fixtures 7VCR 12-5/8" [321mm] 11-3/8" [289mm] 6-5/8" [168mm] Compliances may not apply to all product configurations. Please consult the product spec sheet for compliance details. COMPLIANCES: UL/cUL Listed - Damp Location, ARRA Compliant, NYC Code Compliant 6" [152mm] 12" [305mm] 7-VCR ORDERING INFORMATIONΔ SAMPLE NUMBER: 7VCR-12-1T5-ETG-1EB-SI-S62A Series Mounting Fixture Size Number of Lamps (Not Included) Lamp Type Ceiling Type Run Length Voltage Ballast 7VC=Specialty R=Recessed 12=1'x2' 14=1'x4' 22=2'x2' 1=1 Lamp 2=2 Lamps BX40W=BX40W BX50W=BX50W T5=T5 T5HO=T5HO ETG=15/16" Exposed T-grid SR=Sheetrock® (Flanged) 1 STG=Slot T-grid Overall Nominal Run Length __ ft. 1=120V 2=277V 3=347V DB=Dimming Ballast EB=Electronic Ballast (Standard) Switching Options Emergency Fusing Shielding Options DU=Double Switching SI=Single Switching EM=Emergency Pack (Consult Factory) GLR=GLR GMF=GMF S62A=Lateral Aluminum Baffle NOTES: Δ Due to various constraints, some options may not be combined with others. Please consult your Cooper Lighting Representative for availability. 1. Fixture must be installed prior to ceiling. MOUNTING INFORMATION STG Slot T-Grid SR Sheetrock NEO-RAY ETG Exposed T-Grid Specifications and dimensions subject to change without notice. Consult your Cooper Lighting Representative or visit www.cooperlighting.com for available options, accessories and ordering information. 9-47 Cooper Lighting by Eaton | Product Selection Guide | Sixth Edition | www.cooperlighting.com Tie wire (not by Neo-Ray) 11-15/16" 10-3/4" Compliances may not apply to all product configurations. Please consult the product spec sheet for compliance details. COMPLIANCES: UL/cUL Listed - Damp Location, ARRA Compliant, NYC Code Compliant 1-3/8"7/8" 1/2" Pentaflex reflector Ceiling extrusion Wall rail Wall extrusion PERIMETER DIRECT FEATURES rDirect wall wash perimeter light distribution rDie-formed 20-gauge steel housing in 3', 4', 6' and 8' sections r Pentaflex™ reflector system for seamless continuous runs rSoftly graduated wall illumination without lamp socket shadows rLamps are shielded at all angles by an aluminum extruded ceiling rail r Runs are field-adjustable rOptional 90° mitered corners 9-1/32" 8" 7-11/32" Fixture opening 79-PF 8-5/8" Ceiling opening ORDERING INFORMATIONΔ SAMPLE NUMBER: 79PF-2T5-68'-UEB-SI Series =79PF Number of Lamps (Not Included) Lamp Type Length of run along the wall 1 Voltage Ballast Switching Options Emergency Fusing Flanged End Plate Option 2 1=1 Lamp 2=2 Lamps T5=T5 T5HO=T5HO T8=T8 XX=___Ft___In 1=120V 2=277V 3=347V U=Universal (120-277V) DB=Dimming Ballast EB=Electronic Ballast (Standard) DU=Dual Switching SI=Single Switching EM=Emergency Pack (Consult Factory) GLR=GLR GMF=GMF EP=End Plate NOTES: Δ Continuous run fixture only - not available as an individual fixture. Actual wall length must be provided. 1. Do not round up. provided. If flanged end plate is required, order EP. See graphics on page 2. NOTE: Not available as an individual fixture. 2. A pair of End Closures per run is provided by default. No flanged end plates are MOUNTING INFORMATION NOTE: A pair of End Closures per run are provided by default. No flanged end plates are provided. If flanged end plate is required, order “EP”. EP contains a pair of left and right flanged end plates. 12-1/4" Pattern leg 1 12-1/4" Inside corner 90° unlit Pattern leg 2 Outside corner 90° unlit Extension End closure [no flange] (for wall) Wall Wall side 2-11/16" 2-11/16" Pattern leg 3 Patterns require corner sections (Must order corners separately as required) EP=flanged end plate option: attach flanged end plate to trim tile or sheetrock NEO-RAY Specifications and dimensions subject to change without notice. Consult your Cooper Lighting Representative or visit www.cooperlighting.com for available options, accessories and ordering information. Cooper Lighting by Eaton | Product Selection Guide | Sixth Edition | www.cooperlighting.com 9-48 PERIMETER INDIRECT Tie wire (not by Neo-Ray) FEATURES r Indirect wall wash perimeter light distribution r Die-formed 20-gauge steel housing in 3', 4', 6' and 8' sections r Softly graduated wall illumination without lamp socket shadows r Runs are field-adjustable r Lamps shielded from all viewing angles r Optional 90° mitered corners create finished ceiling details r Illuminated wall continues beyond ceiling, creating a floating effect 1/2" 12-9/16" 7/8" Wall rail 9" 9-3/8" Compliances may not apply to all product configurations. Please consult the product spec sheet for compliance details. Ceiling extrusion COMPLIANCES: UL/cUL Listed - Damp Location, ARRA Compliant, NYC Code Compliant 1-5/8" 9" nominal fixture opening 79-OS 9-5/16" ceiling opening ORDERING INFORMATION SAMPLE NUMBER: 79OS-1T5-72'-UEB-SI Series Number of Lamps (Not Included) Lamp Type Length of Run Along the Wall 1 Voltage Ballast Switching Options Emergency 79OS=79OS 1=1 Lamp T5=T5 T5HO=T5HO T8=T8 XX=___Ft___In 1=120V 2=277V 3=347V U=Universal (120-277V) DB=Dimming Ballast EB=Electronic Ballast (Standard) SI=Single Switching EC=Emergency Circuit EM=Emergency Pack (Consult Factory) Fusing Flanged End Plate Option 2 GLR=GLR GMF=GMF EP=End Plate NOTES: 1. Do not round up. 2. No flanged end plates are provided. Wall serves as the end condition. If flanged end plate is required, order EP. MOUNTING INFORMATION 13-3/8" Pattern leg 1 13-3/8" Inside corner 90° unlit Pattern leg 2 Outside corner 90° unlit Extension NOTE: No flanged end plates are provided. Wall serves as the end condition. If flanged end plate is required, order “EP”. EP contains a pair of left and right flanged end plates. EP=flanged end plate option: use to trim tile or sheetrock Standard end condition at fixture ends (wall) Wall rail Wall side 2" 2" Pattern leg 3 Telescoping housing section 0.875" feed k.O. Ceiling extrusion Mount to housing flange NEO-RAY Patterns require corner sections (Must order corners separately as required) Tie wire (not provided by Neo-Ray) Specifications and dimensions subject to change without notice. Consult your Cooper Lighting Representative or visit www.cooperlighting.com for available options, accessories and ordering information. 9-49 Cooper Lighting by Eaton | Product Selection Guide | Sixth Edition | www.cooperlighting.com 8-23/32" [221mm] 8" [203mm] Compliances may not apply to all product configurations. Please consult the product spec sheet for compliance details. COMPLIANCES: UL/cUL Listed - Damp Location, ARRA Compliant, NYC Code Compliant 9/16" [15mm] 1/4" [7mm] PERIMETER DIRECT FEATURES rDirect wall wash perimeter light distribution rDie-formed 20-gauge steel housings in 3', 4', 6' and 8' sections r Extruded-aluminum ceiling trims rStaggered light strips rRuns are field-adjustable r Optional 90° mitered corners rSelection of shielding options 7-11/16" [195mm] 9-1/4" [235mm] Ceiling opening 9-1/2" [242mm] 78 ORDERING INFORMATIONΔ SAMPLE NUMBER: 78-1T5-52'-1EB-SI-S79 Series Number of Lamps (Not Included) Lamp Type Run Length Voltage 1 Ballast Switching Options Emergency 78=Perimeter 1=1 Lamp 2=2 Lamps T5=T5 T5HO=T5HO T8=T8 Overall Nominal Run Length __ ft. 1=120V 2=277V 3=347V DB=Dimming Ballast EB=Electronic Ballast (Standard) DU=Double Switching SI=Single Switching EM=Emergency Pack (Consult Factory) Fusing Shielding Options GLR=GLR GMF=GMF S10=Parabolic Baffle S11=Bold Baffle S72=Bold Baffle S79=Parabolic Baffle NOTES: Δ Fixture must be installed prior to ceiling. 1. Not all options available. Please consult your Cooper Lighting Representative for availability. RUNS AND PATTERNS Standard illuminated sections contain mitered corners installed continuous and unbroken, and are field adjusted 12-1/16" inside mitered corner Standard illuminated sections 12-5/16" outside mitered corner Field cut to suit SHIELDING OPTIONS S11 Parabolic Baffle S72 Bold Baffle S79 Parabolic Baffle NEO-RAY S10 Parabolic Baffle 90° Mitered Baffle Specifications and dimensions subject to change without notice. Consult your Cooper Lighting Representative or visit www.cooperlighting.com for available options, accessories and ordering information. Cooper Lighting by Eaton | Product Selection Guide | Sixth Edition | www.cooperlighting.com 9-50 PERIMETER DIRECT 12" [305mm] FEATURES r Direct wall wash perimeter light distribution r Die-formed 20-gauge steel housing in 3', 4', 6' and 8' sections r Pentaflex™ reflector system for seamless continuous runs r Staggered lighting for even illumination r Extruded-aluminum ceiling trims r Selection of shielding options r Optional 90° mitered corners r Runs are field-adjustable 8-1/2" [216mm] Compliances may not apply to all product configurations. Please consult the product spec sheet for compliance details. COMPLIANCES: UL/cUL Listed - Damp Location, ARRA Compliant, NYC Code Compliant 7-11/16" [196mm] 9-1/8" [232mm] Ceiling to wall opening 76-PF 9-1/2" [242mm] ORDERING INFORMATION SAMPLE NUMBER: 76PF-1T8-30'-1EB-SI-S72 Series Number of Lamps (Not Included) Lamp Type Run Length Voltage 1 Ballast Switching Options Emergency Fusing Shielding Options 76PF=Perimeter with Pentaflex 1=1 Lamp 2=2 Lamps T5=T5 T5HO=T5HO T8=T8 Overall Nominal Run Length __ ft. 1=120V 2=277V 3=347V DB=Dimming Ballast EB=Electronic Ballast (Standard) DU=Double Switching SI=Single Switching EM=Emergency Pack (Consult Factory) GLR=GLR GMF=GMF S58=KSH-12 Acrylic Lens S72=Bold Baffle S79=Parabolic Baffle NOTES: 1. Not all options available. Please consult your Cooper Lighting Representative for availability. RUNS AND PATTERNS Standard illuminated sections contain mitered corners installed continuous and unbroken, and are field adjusted 12-1/16" inside mitered corner Standard illuminated sections 12-5/16" outside mitered corner Aluminum housing field cut to suit NEO-RAY SHIELDING OPTIONS S58 Acrylic Lens S72 Bold Baffle S79 Parabolic Baffle Specifications and dimensions subject to change without notice. Consult your Cooper Lighting Representative or visit www.cooperlighting.com for available options, accessories and ordering information. 9-51 Cooper Lighting by Eaton | Product Selection Guide | Sixth Edition | www.cooperlighting.com Tie-wire (not by Neo-Ray) 3-15/16" PERIMETER DIRECT FEATURES rDirect light distribution rDie-formed 20-gauge steel housing in 3', 4', 6' and 8' sections r Staggered light strips rNumerous shielding options rFixture ceiling trims can accommodate various grids and constructions r Durable, low gloss, white, baked powder coated finish rDimming and emergency options rFixtures are UL and CUL listed 6" Wall rail finish: black Compliances may not apply to all product configurations. Please consult the product spec sheet for compliance details. COMPLIANCES: UL/cUL Listed - Damp Location, ARRA Compliant, NYC Code Compliant 1/4" Ceiling tile by others 3/8" 3-3/16" 4-7/8"±1/8" 5/8"±1/8" 75 Slot T-grid (STG) with bold baffle (S72) ORDERING INFORMATION SAMPLE NUMBER: 75R-2T5-ETG-20'-UEB-SI-S72 Series Mounting Type Number of Lamps (Not Included) Lamp Type Ceiling Type Run Length Voltage Ballast 75=Perimeter R=Recessed 1=1 Lamp 2=2 Lamps T5=T5 T5HO=T5HO T8=T8 ETG=1 1/2" High X 15/16" Flat T-grid FSR=Sheetrock® (Flangeless) FTG=1 1/2" High X 9/16" Flat T-grid GTG=1 11/16" High X 9/16" Flat T-grid HTG=1 11/16" High X 15/16" Flat T-grid SR=Sheetrock® (Flanged) STG=1 3/4" High X 9/16" Slot T-grid __=Ft 1=120V 2=277V 3=347V U=Universal (120-277V) DB=Dimming Ballast EB=Electronic Ballast (Standard) Switching Options Emergency Fusing Shielding Options DU=Double Switching SI=Single Switching EM=Emergency Pack (Consult Factory) GLR=GLR GMF=GMF S22=White Acrylic Diffuser withMullion S58=Clear Acrylic Prismatic Lens withMullion S72=Bold Baffle S72P=Bold Baffle with Overlay S72PF=Bold Baffle with Perforated Blades S72PP=Bold Baffle with Perforated Blades and Overlay S79=Semi-Specular Aluminum Parabolic Louvre S79P=Semi-Specular Aluminum Parabolic Louvre with Overlay SHIELDING OPTIONS AND FEATURES S72 Bold Baffle S79 Parabolic Baffle S22 Acrylic Diffuser NEO-RAY S58 Acrylic Lens 90° and 135° Illuminated Inside and Outside Corners Available Specifications and dimensions subject to change without notice. Consult your Cooper Lighting Representative or visit www.cooperlighting.com for available options, accessories and ordering information. Cooper Lighting by Eaton | Product Selection Guide | Sixth Edition | www.cooperlighting.com 9-52 PERIMETER DIRECT FEATURES r Direct wall wash perimeter light distribution r Die-formed 20-gauge steel housing for 3', 4', 6' and 8' sections r Field-adjustable runs r Optional 90° mitered corners Compliances may not apply to all product configurations. Please consult the product spec sheet for compliance details. COMPLIANCES: UL/cUL Listed - Damp Location, ARRA Compliant, NYC Code Compliant 10-1/2" [267mm] ± 3/4" [19mm] 72 9" [229mm] 1/2" [13mm] 9-1/8" [232mm] Ceiling opening ORDERING INFORMATIONΔ SAMPLE NUMBER: 72-1T5-26'-1EB-SI Series Number of Lamps (Not Included) Lamp Type Run Length Voltage 1 Ballast Switching Options Emergency Fusing 72=Perimeter 1=1 Lamp 2=2 Lamps T5=T5 T5HO=T5HO T8=T8 Overall Nominal Run Length __ ft. 1=120V 2=277V 3=347V DB=Dimming Ballast EB=Electronic Ballast (Standard) DU=Double Switching SI=Single Switching EM=Emergency Pack (Consult Factory) GLR=GLR GMF=GMF NOTES: Δ Fixture must be installed prior to ceiling. 1. Not all options available. Please consult your Cooper Lighting Representative for availability. RUN AND PATTERNS Patterns are provided in 1' increments plus fill-in section, field cut to suit 9" x 9" corner box NEO-RAY Patterns are provided in 1' increments plus field cut fill-in section and mitered corner Specifications and dimensions subject to change without notice. Consult your Cooper Lighting Representative or visit www.cooperlighting.com for available options, accessories and ordering information. 9-53 Cooper Lighting by Eaton | Product Selection Guide | Sixth Edition | www.cooperlighting.com PERIMETER DIRECT FEATURES rDirect wall wash perimeter light distribution rDie-formed 20-gauge steel housing for 3', 4', 6' and 8' sections r Regressed shielding options rField-adjustable runs rOptional 90° mitered corners 10-1/2" [267mm] ± 3/4" [19mm] Compliances may not apply to all product configurations. Please consult the product spec sheet for compliance details. COMPLIANCES: UL/cUL Listed - Damp Location, ARRA Compliant, NYC Code Compliant 9" [229mm] 1/2" [13mm] 71 9-1/8" [232mm] Ceiling opening ORDERING INFORMATIONΔ SAMPLE NUMBER: 71-1T5-32'-1EB-SI-S62 Series Number of Lamps (Not Included) Lamp Type Run Length Voltage 1 Ballast Switching Options Emergency Fusing Shielding Options 71=Perimeter 1=1 Lamp 2=2 Lamps T5=T5 T5HO=T5HO T8=T8 Overall Nominal Run Length __ ft. 1=120V 2=277V 3=347V DB=Dimming Ballast EB=Electronic Ballast (Standard) DU=Double Switching SI=Single Switching EM=Emergency Pack (Consult Factory) GLR=GLR GMF=GMF S58=KSH-12 Acrylic Lens S62=Lateral Louver NOTES: Δ Fixture must be installed prior to ceiling. 1. Not all options available. Please consult your Cooper Lighting Representative for availability. RUNS AND PATTERNS Patterns are provided in 1' increments plus fill-in section, field cut to suit 9" x 9" corner box Patterns are provided in 1' increments plus field cut fill-in section and mitered corner SHIELDING OPTIONS NEO-RAY S58 Acrylic Lens S62 Lateral Louver Specifications and dimensions subject to change without notice. Consult your Cooper Lighting Representative or visit www.cooperlighting.com for available options, accessories and ordering information. Cooper Lighting by Eaton | Product Selection Guide | Sixth Edition | www.cooperlighting.com 9-54 PERIMETER DIRECT FEATURES r Direct wall wash perimeter light distribution r Die-formed 20-gauge steel housing for 3', 4', 6' and 8' sections r Field-adjustable run configurations r Four shielding options available r Optional 90° mitered corners 10-1/2" [267mm] 3/4" [19mm] Compliances may not apply to all product configurations. Please consult the product spec sheet for compliance details. COMPLIANCES: UL/cUL Listed - Damp Location, ARRA Compliant, NYC Code Compliant 7-3/4"[197mm] 70 9" [229mm] 9-1/8" [232mm] Ceiling opening ORDERING INFORMATION SAMPLE NUMBER: 70-1T8-20'-1EB-SI-S79 Series Number of Lamps (Not Included) Lamp Type Run Length Voltage 1 Ballast Switching Options Emergency Fusing Shielding Options 70=Perimeter 1=1 Lamp 2=2 Lamps T5=T5 T5HO=T5HO T8=T8 Overall Nominal Run Length __ ft. 1=120V 2=277V 3=347V DB=Dimming Ballast EB=Electronic Ballast (Standard) DU=Double Switching SI=Single Switching EM=Emergency Pack (Consult Factory) GLR=GLR GMF=GMF S22=White Acrylic Diffuser S58=KSH-12 Acrylic Lens S72=Bold Baffle S79=Parabolic Baffle NOTES: 1. Not all options available. Please consult your Cooper Lighting Representative for availability. RUNS AND PATTERNS Patterns are provided in 1' increments plus fill-in section, field cut to suit 9" x 9" corner box Patterns are provided in 1' increments plus field cut fill-in section and mitered corner NEO-RAY SHIELDING OPTIONS S22 Acrylic Diffuser S58 Acrylic Lens S72 Bold Baffle S79 Parabolic Baffle Specifications and dimensions subject to change without notice. Consult your Cooper Lighting Representative or visit www.cooperlighting.com for available options, accessories and ordering information. 9-55 Cooper Lighting by Eaton | Product Selection Guide | Sixth Edition | www.cooperlighting.com Solid blocking to prevent sagging (not by Neo-Ray) COVE INDIRECT FEATURES rOptics provide uniform, indirect illumination rLow-profile, crisp extruded aluminum housing r Semi-specular aluminum and white steel reflector rDurable, low-gloss, white, powder-coated paint rFixture lengths of 3', 4', 6' and 8' r Run configurations to the nearest foot 3/4" 1-3/4" 1/4" 6" Compliances may not apply to all product configurations. Please consult the product spec sheet for compliance details. 1/2" 6-1/2" COMPLIANCES: UL/cUL Listed - Damp Location, ARRA Compliant, NYC Code Compliant AL-COVE 74-IW ORDERING INFORMATIONΔ SAMPLE NUMBER: 74IW-1T5-12'-UEB-SI Series Light Output Mounting Number of Lamps (Not Included) Lamp Type Run Length Voltage Ballast Switching Options 74 I=Indirect W=Wall 1=1 Lamp T5=T5 T5HO=T5HO T8=T8 __=FT 1=120V 2=277V 3=347V U=Universal (120-277V) DB=Dimming Ballast EB=Electronic Ballast (Standard) DU=Double Switching SI=Single Switching Emergency Fusing EM=Emergency Pack (Consult Factory) GLR=GLR GMF=GMF NOTES: Δ Individual fixtures cannot be combined into runs. BACKSIDE VIEW FOR MOUNTING AND FEED POINT LOCATION Dimensions shown for intermediate fixture. For IND, BOR and EOR fixture add 1/8" for end plates 4" 26-3/4" 4" 1-1/2" 38-9/16" 3/4" 46-9/16" 34-3/4" 4" 30-1/2" 1-3/4" TYP 69" 4" - Feed Hole - Mounting Hole 42-9/32" 92-9/16" NEO-RAY Specifications and dimensions subject to change without notice. Consult your Cooper Lighting Representative or visit www.cooperlighting.com for available options, accessories and ordering information. Cooper Lighting by Eaton | Product Selection Guide | Sixth Edition | www.cooperlighting.com 9-56 COVE INDIRECT FEATURES r Indirect cove light distribution r Reflector directs light outward at low angles for glare-free lighting r Smooth ceiling light gradation eliminates lamp socket shadows r Sturdy die-formed 20-gauge steel housing r Durable, low-gloss powder-coat paint finish r Lay-in at wall cove for easy installation (1) T5 OR T5HO Compliances may not apply to all product configurations. Please consult the product spec sheet for compliance details. (1 OR 2) T8 OR (1 OR 2) BIAX 1-3/4" [44mm] 6" [152mm] COMPLIANCES: UL/cUL Listed - Damp Location, ARRA Compliant, NYC Code Compliant 3" [76mm] 74-IC 8" [203mm] ORDERING INFORMATION SAMPLE NUMBER: 74IC-1T5-32'-UEB-SI Series Light Output Mounting Number of Lamps (Not Included) Lamp Type 1 Run Length Voltage 1 Ballast Switching Options 74=Cove I=Indirect C=Cove 1=1 Lamp 2=2 Lamps BX40W=BX40W 2 BX50W=BX50W T5=T5 T5HO=T5HO T8=T8 Overall Nominal Run Length __ ft. 1=120V 2=277V 3=347V U=Universal (120-277V) DB=Dimming Ballast EB=Electronic Ballast (Standard) DU=Double Switching SI=Single Switching Emergency Fusing EM=Emergency Pack (Consult Factory) GLR=GLR GMF=GMF NOTES: 1. Not all options available. Please consult your Cooper Lighting Representative for availability. 2. All 3' fixtures utilize a BX36W lamp only. RUN INFORMATION FIXTURE LENGTH T5 T8 BIAX 2' 22-5/8" 24" 23" (40/50W) 3' 34-3/8" 36" 34" (36W) 4' 46-3/16" 48" 46" (40/50W) 6' 68-5/8" 72" 69" (40/50W) 8' 92-3/16" 96" 92" (40/50W) 22-5/8"-2' BOR 34-1/4"-3' BOR 46-1/8"-4' BOR 68-1/2"-6' BOR 92-1/8"-8' BOR 22-5/8"-2' INT 34-1/4"-3' INT 46-1/8"-4' INT 68-1/2"-6' INT 92-1/8"-8' INT 22-5/8"-2' EOR 34-1/4"-3' EOR 46-1/8"-4' EOR 68-1/2"-6' EOR 92-1/8"-8' EOR Overall length of run NEO-RAY Typical run detail Specifications and dimensions subject to change without notice. Consult your Cooper Lighting Representative or visit www.cooperlighting.com for available options, accessories and ordering information. 9-57 Cooper Lighting by Eaton | Product Selection Guide | Sixth Edition | www.cooperlighting.com 1-7/8" [48mm] 2-7/8" [74mm] Compliances may not apply to all product configurations. Please consult the product spec sheet for compliance details. COMPLIANCES: UL/cUL Listed - Damp Location, ARRA Compliant, NYC Code Compliant 7-1/2" [191mm] S52DIP/2T8 with louver PANELIT 52 DIP SUSPENDED ARCHITECTURAL DIRECT-INDIRECT FEATURES rLow profile suspended 1-7/8" x 7-1/2" extruded aluminum housing rIndividual or continuous runs in 3', 4', 5', 6', 8' and 10' lengths r Precise, clean look and finish with mitered ends rDie-formed semi-specular anodized aluminum reflector rSemi-specular parabolic louver option r High transmission frosted acrylic lens option rDurable, low-gloss, white, powder-coated finish rCable- or stem-mount option ORDERING INFORMATIONΔ SAMPLE NUMBER: 52DIP-1T5-SC-48-T1-20’-1-EB-SI-S85 Series Number of Lamps (Not Included) Lamp Type Suspension Suspension Length Ceiling Type Length 3 Voltage 4 52DIP=Suspended Direct-Indirect Pendant 1=1 Lamp 2=2 Lamp T5=T5 T5HO=T5HO T8=T8 SC=Single Aircraft Cable 1 ST=Single Rigid Stem 2 Adjustable Cable=48" Stem=18", 24" or 36" JB=4" Square J-Box ST=Structure T1=1" T-Bar T9=9/16" T-Bar TS=Slotted T-Bar 3D=3' 4D=4' 5D=5' 6D=6' 8D=8' 10D=10' xx=Continuous Run 120=120v 277=277v 347=347v U=Universal (120-277V) Ballast 4 Switching Emergency (Optional) 4 Shielding Fusing (optional) Sensor Options DB=Dimming Ballast EB=Electronic Ballast (Standard) DU=Dual Circuit SI=Single Circuit EC=Emergency Circuit EM=Emergency Pack S85=Semi-Specular Parabolic Louver with High Transmission Overlay S85N=Semi-Specular Parabolic Louver S86=High Transmission Frosted Acrylic Lens with Rectangular Perforated Pattern S95HT=High Transmission Frosted Acrylic Lens GLR=GLR GMF=GMF 2S=Daylight and Occupancy Sensor DS=Daylight Sensor NOTES: Δ For some electronic, dimming and EM battery pack ballast combinations, fixture has space limitation (consult factory). Δ Standard EM Pack is for 1 lamp. Δ For dimming, specify ballast option. Δ Rigid Stem mount does not have a feed cord. Feed wires are inside the stem mount. 1. Pendant feed cord is straight for single Aircraft Cable mounting. 2. For T5 lamping only. 3. Continuous runs are made of 3', 4', 6' and 8' sections using 3' and 4' lamps. 4. Required voltage information. Maximum ballast size 1.75" x 1.2". MOUNTING INFORMATION T8 Individual 1-3/8" [35mm] T8 Continuous 35-3/4" - 3' 47-3/4" - 4' 59-3/4" - 5' 71-3/4" - 6' 95-3/4" - 8' 119-3/4" - 10' 1-3/8" [35mm] 1-3/8" [35mm] 38-1/2" - 3' 50-1/2" - 4' 62-1/2" - 5' 74-1/2" - 6' 98-1/2" - 8' 122-1/2" - 10' 35-3/4" - 3' BOR 47-3/4" - 4' BOR 71-3/4" - 6' BOR 95-3/4" - 8' BOR 36" - 3' INT 48" - 4' INT 1/8" 72" - 6' INT [4mm] 96" - 8' INT Beginning of run Intermediate 37-1/4" - 3' BOR 49-1/4" - 4' BOR 73-1/4" - 6' BOR 97-1/4" - 8' BOR 36" - 3' INT 48" - 4' INT 72" - 6' INT 96" - 8' INT 36" - 3' EOR 48" - 4' EOR 1/8" 72" - 6' EOR [4mm] 96" - 8' EOR 1-3/8 [35m End of run 37-1/4" - 3' EOR 49-1/4" - 4' EOR 73-1/4" - 6' EOR 97-1/4" - 8' EOR Overall length of run SHIELDING AND SENSOR OPTIONS S86 Frosted Acrylic Lens with Rectangular Perforated Pattern S85 Semi-Pecular Parabolic Louver with High Transmission Acrylic Overlay S85N Semi-Specular Parabolic Louver without Overlay Occupancy Sensor NEO-RAY 95HT High Transmission Frosted Acrylic Lens Daylight Sensor Specifications and dimensions subject to change without notice. Consult your Cooper Lighting Representative or visit www.cooperlighting.com for available options, accessories and ordering information. Cooper Lighting by Eaton | Product Selection Guide | Sixth Edition | www.cooperlighting.com 9-58 SUSPENDED ARCHITECTURAL SEMI-INDIRECT FEATURES r Semi-indirect light distribution r Fully perforated and illuminated die-formed, 20-gauge steel housing r Two Biax™ lamping r Nominal 4' long fully illuminated sections r Optional slotted perforated pattern r Precision die-cast end caps r Articulated joiners 21" [533mm] minimum 3-1/2" [89mm] Compliances may not apply to all product configurations. Please consult the product spec sheet for compliance details. 16" [406mm] COMPLIANCES: UL/cUL Listed - Damp Location, ARRA Compliant, NYC Code Compliant NUAGE 301-IP ORDERING INFORMATION SAMPLE NUMBER: 301IP-2BX40-SC-40'-1EB-RP-SI Series Light Output Mounting Number of Lamps (Not Included) Lamp Type Pendant Run Length Voltage Ballast 301=Nuage I=Indirect P=Pendant 2=2 Lamps BX40W=BX40W BX50W=BX50W DC=Dual Cable DS=Dual Stem SC=Single Cable ST=Single Stem 1 Overall Nominal Run Length __ ft. 1=120V 2=277V 3=347V DB=Dimming Ballast EB=Electronic Ballast (Standard) Switching Options Perforation Emergency Fusing DU=Double Switching SI=Single Switching BP=None RP=Round SP=Slotted EM=Emergency Pack (Consult Factory) GLR=GLR GMF=GMF NOTES: 1. Available with 7° or earthquake 45° swivel canopy assembly. MOUNTING INFORMATION 4' Row 8' Row 7-1/2" [190mm] 7-1/2" [190mm] 7' - 11" [2413mm] 40" [1016mm] 40" [1016mm] 3' - 11" [1193mm] 32" [813mm] 47" [1194mm] 47" [1194mm] 1" [26mm] 12' Row 7-1/2" [190mm] 7-1/2" [190mm] 11' - 11" [3632mm] 40" [1016mm] 1" [26mm] 40" [1016mm] 1" [26mm] Articulated Joiner NEO-RAY 47" [1194mm] 48" [1219mm] Specifications and dimensions subject to change without notice. Consult your Cooper Lighting Representative or visit www.cooperlighting.com for available options, accessories and ordering information. 9-59 Cooper Lighting by Eaton | Product Selection Guide | Sixth Edition | www.cooperlighting.com 18" [457mm] minimum 3-1/2" [89mm] Compliances may not apply to all product configurations. Please consult the product spec sheet for compliance details. 16" [406mm] COMPLIANCES: UL/cUL Listed - Damp Location, ARRA Compliant, NYC Code Compliant NUAGE 301-IP, 301-DL SUSPENDED ARCHITECTURAL DIRECT-INDIRECT FEATURES rSemi-indirect, direct light distribution r Discrete indirect, direct dual switching with downlights r Fully perforated and illuminated die-formed 20-gauge steel housing rNominal 4' long fully illuminated sections with BIAX™ lamping r Precision die-cast end caps r Optional slotted perforated pattern rArticulated joiners ORDERING INFORMATION SAMPLE NUMBER: 301IP-DLP16-2BX40-SC-24'-1EB-SI-RP Series Light Output Mounting Downlight Downlight Lamp Type (Not Included) Number of Lamps (Not Included) Lamp Type (Not Included) Pendant Run Length 301=Nuage I=Indirect P=Pendant DL=Downlight P16=Par16 P20=Par20 2=2 Lamps BX40W=BX40W BX50W=BX50W DC=Dual Cable DS=Dual Stem SC=Single Cable ST=Single Stem 1 Overall Nominal Run Length __ ft. Voltage Ballast Switching Options Perforation Emergency Fusing 1=120V DB=Dimming Ballast EB=Electronic Ballast (Standard) DU=Double Switching SI=Single Switching BP=None RP=Round SP=Slotted EM=Emergency Pack (Consult Factory) GLR=GLR GMF=GMF NOTES: 1. Available with 7° or earthquake 45° swivel canopy assembly. MOUNTING INFORMATION 4' Row 8' Row 7-1/2" [190mm] 3' - 11" [1193mm] 32" [813mm] 7-1/2" [190mm] 8' Row (detail view) 7-1/2" [191mm] 7' - 11" [2413mm] 40" [1016mm] 40" [1016mm] 47" [1194mm] 47" [1194mm] 1" [26mm] 24" [610mm] Bottom view 24" [610mm] Top view 12' Row 7-1/2" [190mm] 7-1/2" [190mm] 40" [1016mm] 47" [1194mm] 11' - 11" [3632mm] 48" [1219mm] 1" [26mm] 40" [1016mm] 1" [26mm] Articulated joiner NEO-RAY Specifications and dimensions subject to change without notice. Consult your Cooper Lighting Representative or visit www.cooperlighting.com for available options, accessories and ordering information. Cooper Lighting by Eaton | Product Selection Guide | Sixth Edition | www.cooperlighting.com 9-60 SUSPENDED ARCHITECTURAL DIRECT-INDIRECT FEATURES r Direct-indirect light distribution r Two lamp direct or three lamp direct-indirect options r Fully perforated and illuminated die-formed 20-gauge steel housing r Nominal 3', 4', 6' or 8' illuminated sections r Precision die-cast end caps r Optional slotted perforated pattern r Articulated joiners 302-IP 18" [457mm] minimum Compliances may not apply to all product configurations. Please consult the product spec sheet for compliance details. S 3" [76mm] COMPLIANCES: UL/cUL Listed - Damp Location, ARRA Compliant, NYC Code Compliant 12" [305mm] S = Slim line ballast only PETITE NUAGE 302-IP, 302-DIP ORDERING INFORMATION SAMPLE NUMBER: 302IP-2T8-ST60-1EB-SI Series Light Output Mounting Number of Lamps (Not Included) Lamp Type Pendant Run Length Voltage 4 Ballast 302=Nuage DI=Direct-Indirect I=Indirect P=Pendant 2=2 Lamps 3=3 Lamps 1 T5=T5 T5HO=T5HO T8=T8 DC=Dual Cable DS=Dual Stem 2 SC=Single Cable ST=Single Stem 3 Overall Nominal Run Length __ ft. 1=120V 2=277V 3=347V DB=Dimming Ballast EB=Electronic Ballast (Standard) Switching Options Perforation Emergency Fusing DU=Double Switching SI=Single Switching BP=None RP=Round SP=Slotted EM=Emergency Pack (Consult Factory) GLR=GLR GMF=GMF NOTES: 1. DIP is 3 lamps only and IP is 2 lamps only. 2. Dual Stem for DIP only. Representative for availability. 3. Available with 7° or earthquake 45° swivel canopy assembly. 4. Not all options available. Please consult your Cooper Lighting MOUNTING INFORMATION 6' Row 3' Row 4' Row 6-3/8" [162mm] 6-3/8" [162mm] 25" [635mm] 6-3/8" [162mm] 37-3/4" [959mm] 6-3/8" [162mm] 6-3/8" [162mm] 6-3/8" [162mm] 37" [940mm] 61" [1549mm] 49-3/4" [1264mm] 73-3/4" [1873mm] 11' Row 8' Row 6-3/8" [162mm] 85" [2159mm] 6-3/8" [162mm] 6-3/8" [162mm] 43-7/8" [1114mm] 11' - 7-1/4" [3537mm] 50-3/4" [1289mm] 6-3/8" [162mm] 31-7/8" [810mm] 97-3/4" [2483mm] 49-3/4" [1264mm] 1" [26mm] Articulated joiner 20' Row 6-3/8" [162mm] 20'- 7-1/4 [6280] 91-7/8" [2486mm] 97-3/4" [2483mm] 98-3/4" [2508mm] 1" [26mm] Articulated joiners 43-7/8" [1114mm] 1" [26mm] NEO-RAY ALTERNATE LIGHT OUTPUT 302-IP Specifications and dimensions subject to change without notice. Consult your Cooper Lighting Representative or visit www.cooperlighting.com for available options, accessories and ordering information. 9-61 Cooper Lighting by Eaton | Product Selection Guide | Sixth Edition | www.cooperlighting.com 2-1/4" [57mm] S 6-3/4" [171mm] Compliances may not apply to all product configurations. Please consult the product spec sheet for compliance details. S = Slim line ballast only COMPLIANCES: UL/cUL Listed - Damp Location, ARRA Compliant, NYC Code Compliant VICEROY 501-IP SUSPENDED ARCHITECTURAL SEMI-INDIRECT FEATURES rSemi-indirect light distribution rMinimalist fixture profile of 6.75" wide by 2.25" high r Optimized T5 optics for wide light distribution and good efficiency rDie-formed 20-gauge perforated steel housing lengths of 4' and 8' rIncremental mounting on the ceiling grid of 4' and 8' centers r Precision die-cast end caps ORDERING INFORMATION SAMPLE NUMBER: 501IP-SP-2T5-1C-120-AC48-T1-24' Series Optics Up Optics Down Number of Lamps (Not Included) Lamp Type Number of Circuits Wiring Voltage 501IP=Viceroy Suspended S=Specular P=Perforated 1=1 Lamp 2=2 Lamps T5=28W (4' Unit) T5HO=54W (4' Unit) 1=1 Circuit 2=2 Circuits (Side by Side) B=Battery Pack C=Standard Circuit D=Dimming E=Emergency 120=120V 277=277V 347=347V Suspension Power Feed Suspension Length Ceiling Type Run Length A=Aircraft Cable P=Rigid Pendant (Single Stem) 1 S=Single Swivel Pendent C=Straight Cord K=Curly Cord P=Rigid Pendant Adjustable j Cable 48", 120" or 240" (Infinite adjustment along entire length of cable) JB=4" Octagonal J-Box ST=Structure T1=1" T-Bar T9=9/16" T-Bar TS=Slotted T-Bar Specify row length in feet. Rows will be configured with 4' and 8' sections only. Fixed Cable 12", 15", 18", 21", 24", or 27" NOTES: 1. Available with 7° or earthquake 45° swivel canopy assembly. END CAP MOUNTING INFORMATION Standard modular installation Viceroy’s modular design aligns precisely with standard suspended tile ceileings for simplicity in layout and installation. A unique metal clip snaps to the ceiling grid providing a location for a tie-wire structural connection as well as a support point for the luminaire suspension cable. Sheetrock ceiling applications require a simple J-Box strap that provides luminaire support once physically secured to a junction box. 4'-0" or 8'-0" 4'-0" or 8'-0" Neo-Ray’s Viceroy accomodates all ceiling type, please consult factory for mounting applications not depicted. AC_T1 Power Mount Detail-Suspended Tile Ceiling AC_JB Power Mount Detail-Sheetrock Ceiling 1-1/4" [32mm] AC_T1 Non-Power Mount Detail-Suspended Tile Ceiling STANDARD LUMINAIRE LENGTHS* 48"[1219mm]* 96"[2438mm]* *Dimensions do not include end caps NEO-RAY Specifications and dimensions subject to change without notice. Consult your Cooper Lighting Representative or visit www.cooperlighting.com for available options, accessories and ordering information. Cooper Lighting by Eaton | Product Selection Guide | Sixth Edition | www.cooperlighting.com 9-62 SUSPENDED ARCHITECTURAL SEMI-INDIRECT FEATURES r Semi-indirect light distribution r Minimalist fixture profile of 8.75" wide by 1.625" high r Optimized T5 optics for wide light distribution and high efficiency r Die-formed modular 20-gauge steel housing lengths of 4' and 8' r Incremental mounting on the ceiling grid of 4' and 8' centers r Standard or tapered precision die-cast end caps 1-5/8" [41mm] S 8-3/4" [222mm] S = Slim line ballast only Compliances may not apply to all product configurations. Please consult the product spec sheet for compliance details. COMPLIANCES: UL/cUL Listed - Damp Location, ARRA Compliant, NYC Code Compliant NIMBUS I 601-IP ORDERING INFORMATION SAMPLE NUMBER: 601IP-SP-2T5-1C-UNV-AC48-T1-24'-ET Series Optics Up Optics Down Number of Lamps (Not Included) Lamp Type Number of Circuits 1 Wiring 1 Voltage 1 601IP=Nimbus I Suspended S=Specular N=None P=Perforated 2=2 Lamps T5=28W (4' Unit) T5HO=54W (4' Unit) 1=1 Circuit 2=2 Circuits (Side by Side) B=Battery Pack C=Standard Circuit D=Dimming E=Emergency T=Nightlight 120=120V 277=277V 347=347V UNV=Universal (120V-277V) Suspension Power Feed 1 Suspension Length Ceiling Type Run Length End Cap A=Aircraft Cable P=Rigid Pendant (Single Stem) 2 C=Straight Cord K=Curly Cord P=Rigid Pendant Adjustable j Cable 48", 120" or 240" (Infinite adjustment along entire length of cable) JB=4" Octagonal J-Box ST=Structure T1=1" T-Bar T9=9/16" T-Bar TS=Slotted T-Bar Specify row length in feet. Rows will be configured with 4' and 8' sections only. ES=Straight ET=Tapered Fixed Cable 12", 15", 18", 21", 24", or 27" NOTES: 1. Not all options available. Please consult your Cooper Lighting Representative for availability. 2. Available with 7° or earthquake 45° swivel canopy assembly. MOUNTING INFORMATION Standard joining – precise alignment with supsended tile ceiling 48" 48" 96" 96" END CAP “ES” (Straight - standard) End cap - side view 6" [152mm] Beginning or end of run Intermediate END CAP “ET” (Tapered) End cap - side view NEO-RAY 4-1/4" [108mm] Specifications and dimensions subject to change without notice. Consult your Cooper Lighting Representative or visit www.cooperlighting.com for available options, accessories and ordering information. 9-63 Cooper Lighting by Eaton | Product Selection Guide | Sixth Edition | www.cooperlighting.com 1-3/4" [44mm] S S 8-5/8" [218mm] S = Slim line ballast only Compliances may not apply to all product configurations. Please consult the product spec sheet for compliance details. COMPLIANCES: UL/cUL Listed - Damp Location, ARRA Compliant, NYC Code Compliant TWIN BEAM 611-IP SUSPENDED ARCHITECTURAL SEMI-INDIRECT FEATURES rSemi-indirect light distribution rMinimalist fixture profile of 8.625" wide by 1.75" high r Signature two-section "void" detail rOptimized T5 optics for wide light distribution and good efficiency rDie-formed 20-gauge perforated steel housing r Incremental mounting on the ceiling grid of 4' and 8'centers rPrecision die-cast end caps ORDERING INFORMATION SAMPLE NUMBER: 611IP-WP-2T5-1C-120-AC48-T1-24' Series Optics Up Optics Down Number of Lamps (Not Included) Lamp Type Number of Circuits 1 Wiring 1 Voltage 1 611IP=Twin Beam Suspended W=White P=Perforated 2=2 Lamps T5=28W (4' Unit) T5HO=54W (4' Unit) 1=1 Circuit 2=2 Circuits (Side by Side) B=Battery Pack C=Standard Circuit D=Dimming E=Emergency 120=120V 277=277V 347=347V Suspension Power Feed 1 Suspension Length Ceiling Type Run Length A=Aircraft Cable P=Rigid Pendant (Single Stem) 2 C=Straight Cord K=Curly Cord P=Rigid Pendant Adjustable j Cable 48", 120" or 240" (Infinite adjustment along entire length of cable) JB=4" Octagonal J-Box ST=Structure T1=1" T-Bar T9=9/16" T-Bar TS=Slotted T-Bar Specify row length in feet. Rows will be configured with 4' and 8' sections only. Fixed Cable 12", 15", 18", 21", 24", or 27" NOTES: 1. Not all options available. Please consult your Cooper Lighting Representative for availability. 2. Available with 7° or earthquake 45° swivel canopy assembly. END CAP MOUNTING INFORMATION Standard modular installation Twin Beam’s modular design aligns precisely with standard suspended tile ceilings for simplicity in layout and installation. A unique metal clip snaps to the ceiling grid providing a location for a tie-wire structural connection as well as a support point for the luminaire suspension cable. 4'-0" or 8'-0" Sheetrock ceiling applications require a simple J-Box strap that provides luminaire support once physically secured to a junction box. 4'-0" or 8'-0" 1-1/4" [32mm] Neo-Ray’s Twin Beam accommodates all ceiling type, please consult factory for mounting applications not depicted. AC_T1 Power Mount DetailSuspended Tile Ceiling AC_JB Power Mount DetailSheetrock Ceiling AC_T1 Non-Power Mount DetailSheet Rock Ceiling STANDARD LUMINAIRE LENGTHS* 48"[1219mm* NEO-RAY 96"[2438mm]* *Dimensions do not include end caps Specifications and dimensions subject to change without notice. Consult your Cooper Lighting Representative or visit www.cooperlighting.com for available options, accessories and ordering information. Cooper Lighting by Eaton | Product Selection Guide | Sixth Edition | www.cooperlighting.com 9-64 SUSPENDED ARCHITECTURAL SEMI-INDIRECT FEATURES r Semi-indirect light distribution r Die-formed perforated housing reduces contrast and lightens fixture r Incremental mounting on the ceiling grid for 4', 8' and 12' centers r Precision die-cast end caps r Contractor-friendly installation 2-1/2" [63mm] 9" [229mm] Compliances may not apply to all product configurations. Please consult the product spec sheet for compliance details. COMPLIANCES: UL/cUL Listed - Damp Location, ARRA Compliant, NYC Code Compliant NIMBUS II 701-IP ORDERING INFORMATION SAMPLE NUMBER: 701IP-SP-4T8-1C-277-DC48-T1-48 Series Optics Up Optics Down Number of Lamps (Not Included) Lamp Type Number of Circuits 1 Wiring 1 701IP=Nimbus II S=Specular P=Perforated 1=1 Lamp 2=2 Lamps 3=3 Lamps 4=4 Lamps N5=N5 Normal Output T5=T5 High Output T8=T8 Normal Output 1=1 Circuit 2=2 Circuits (Inboard/Outboard) B=Battery Pack C=Standard Circuit D=Dimming E=Emergency T=Nightlight Y=Daylight Voltage 1 Suspension Power Feed 1 Suspension Length Ceiling Type 120=120V 277=277V 347=347V UNV=Universal (120V-277V) A=Aircraft Cable D=Dual Aircraft Cable OR Dual Swivel Rigid Pendant P=Rigid Pendant (Single Stem) 2 C=Straight Cord K=Curly Cord P=Rigid Pendant Adjustable j Cable 48", 120", 240", 300", or 360" (Infinite adjustment along entire length of cable) JB=4" Octagonal J-Box ST=Structure T1=1" T-Bar T9=9/16" T-Bar TS=Slotted T-Bar Rigid g Pendant 3 12", 15", 18", 21", 24", or 27" Run Length Continuously Mounted=Standard row configurations over 12' consist of 8' and 12' sections Individually Mounted=Luminaires may be 4', 8', or 12' in length NOTES: 1. Not all options available. Please consult your Cooper Lighting Representative for availability. 2. Available with 7° or earthquake 45° swivel canopy assembly. 3. Consult factory for custom rigid pendant lengths. END CAP MOUNTING INFORMATION Standard joining – precise alignment with supsended tile ceiling 48" 9" [229mm] 48" 96" 96" 144" 144" 2-1/2" [63mm] 5" [127mm] NEO-RAY Beginning or end of run Intermediate MODULAR ROW CONFIGURATION STANDARD LUMINAIRE LENGTHS " ! " " 48" (1219mm) 96" (2438mm) 12' Row 48" mounting 96" mounting 20' Row Specifications and dimensions subject to change without notice. Consult your Cooper Lighting Representative or visit www.cooperlighting.com for available options, accessories and ordering information. 9-65 Cooper Lighting by Eaton | Product Selection Guide | Sixth Edition | www.cooperlighting.com 2-1/2" [63mm] S 10-3/4" [275mm] S = Slim line ballast only Compliances may not apply to all product configurations. Please consult the product spec sheet for compliance details. COMPLIANCES: UL/cUL Listed - Damp Location, ARRA Compliant, NYC Code Compliant SHELL II 201-IP SUSPENDED ARCHITECTURAL SEMI-INDIRECT FEATURES rSemi-indirect light distribution rDie-formed steel housing for 4', 8' and 12' illuminated sections r Optional articulated joiners rDual aircraft cable hangers for superior leveling rIncremental mounting on the ceiling grid for 4', 8' and 12' centers r Variety of T5 and T8 lamping options rPrecision die-cast end caps rUL and CUL certified ORDERING INFORMATION SAMPLE NUMBER: 201IP-SP-4T8-1C-277-DC48-T1-48 Series Optics Up Optics Down Number of Lamps (Not Included) Lamp Type Number of Circuits 1 Wiring 1 201IP=Shell II S=Specular P=Perforated 1=1 Lamp 2=2 Lamps 3=3 Lamps 4=4 Lamps N5=N5 Normal Output T5=T5 High Output T8=T8 Normal Output 1=1 Circuit 2=2 Circuits (Inboard - Outboard) B=Battery Pack C=Standard Circuit D=Dimming E=Emergency T=Nightlight Y=Daylight Voltage 1 Suspension Power Feed 1 Suspension Length Ceiling Type Run Length Options 120=120V 277=277V 347=347V UNV=Universal (120V-277V) A=Aircraft Cable D=Dual Aircraft Cable OR Dual Swivel Rigid Pendant P=Rigid Pendant (Single Stem) 2 C=Straight Cord K=Curly Cord P=Rigid Pendant Adjustable j Cable 48", 120", 240", 300", or 360" (Infinite adjustment along entire length of cable) JB=4" Octagonal J-Box ST=Structure T1=1" T-Bar T9=9/16" T-Bar TS=Slotted T-Bar Continuously Mounted =Standard row configurations over 12' consist of 8' and 12' sections Individually Mounted =Luminaires may be 4', 8', or 12' in length AJ=Articulated Joining 4 Rigid g Pendant 3 12", 15", 18", 21", 24", or 27" NOTES: 1. Not all options available. Please consult your Cooper Lighting Representative for availability. 2. Available with 7° or earthquake 45° swivel canopy assembly. 3. Consult factory for custom rigid pendant lengths. 4. Articulated Joining option will not align on grids. MOUNTING INFORMATION END CAP Modular configuration Sections align with T-bar ceiling - all sections prewired for thru-wiring with quick-connects 10-3/4" [275mm] ARTICULATED JOINING MOUNTING DETAIL 50" 98" 146" End OPTIONS 1-1/4" 52" 100" 148" Intermediate 2-1/2" [63mm] 8' 8' 1-1/4" [32mm] Modular Configuration STANDARD LUMINAIRE LENGTHS 48"[1219mm]* NEO-RAY 96"[2438mm]* 144"[3658mm]* *Dimensions do not include end caps AJ Articulated Joining Specifications and dimensions subject to change without notice. Consult your Cooper Lighting Representative or visit www.cooperlighting.com for available options, accessories and ordering information. Cooper Lighting by Eaton | Product Selection Guide | Sixth Edition | www.cooperlighting.com 9-66 SUSPENDED ARCHITECTURAL SEMI-INDIRECT FEATURES r Semi-indirect light distribution r T5 and T8 lamping options r Die-formed 20-gauge perforated steel housing r Precision die-cast end caps r Articulated joiners between sections r Optional slotted perforated pattern r UL and CUL certified 18" [457mm] minumum S 3" [76mm] Compliances may not apply to all product configurations. Please consult the product spec sheet for compliance details. 10-1/4" [261mm] COMPLIANCES: UL/cUL Listed - Damp Location, ARRA Compliant, NYC Code Compliant S = Slim line ballast only TRIAD 17-IP ORDERING INFORMATION SAMPLE NUMBER: 17IP-2T5-SC-24'-1EB-SI-RP Series Light Output Mounting Number of Lamps (Not Included) Lamp Type Pendant Run Length Voltage Ballast 3 Switching Options 17=Triad I=Indirect P=Pendant 2=2 Lamps 3=3 Lamps T5=T5 T5HO=T5HO T8=T8 DC=Dual Cable DS=Dual Stem SC=Single Cable 1 ST=Single Stem 1, 2 Overall Nominal Run Length __ ft. 1=120V 2=277V 3=347V DB=Dimming Ballast EB=Electronic Ballast (Standard) DU=Double Switching SI=Single Switching Perforation Emergency Fusing BP=None RP=Round SP=Slotted EM=Emergency Pack (Consult Factory) GLR=GLR GMF=GMF NOTES: 1. Available for 2 lamp fixture only. 2. Available with 7° or earthquake 45° swivel canopy assembly. 3. Not all options available. Please consult your Cooper Lighting Representative for availability. MOUNTING INFORMATION 3' Row 2-3/8" [61mm] 4' Row 2-3/8" [61mm] 33" [838mm] 45" [1143mm] 38-3/4" [984mm] 50-3/4" [1289mm] 6' Row 2-7/8" [74mm] 8' Row 69" [1753mm] 93" [2362mm] 98-3/4" [2508mm] 74-3/4" [1899mm] 12' Row 2-3/8" [61mm] 47-7/8" [1216mm] 51-3/4" [1315mm] 2-7/8" [74mm] 51-3/4" [1315mm] 1" [25mm] 47-7/8" [1216mm] 2-3/8" [61mm] 1" [25mm] NEO-RAY 12' - 8-1/4" [3867mm] Specifications and dimensions subject to change without notice. Consult your Cooper Lighting Representative or visit www.cooperlighting.com for available options, accessories and ordering information. 9-67 Cooper Lighting by Eaton | Product Selection Guide | Sixth Edition | www.cooperlighting.com 16DIP 18" [457mm] minimum S 4" [102mm] Compliances may not apply to all product configurations. Please consult the product spec sheet for compliance details. COMPLIANCES: UL/cUL Listed - Damp Location, ARRA Compliant, NYC Code Compliant 1-1/4" [32mm] 3-3/8" [86mm] 12" [305mm] S = Slim line ballast only EUROPA 16-DIP, 16-IP SUSPENDED ARCHITECTURAL DIRECT-INDIRECT FEATURES rDirect-indirect light distribution rTwo lamp direct or three lamp direct-indirect options r Die-formed 20-gauge perforated steel housing rNominal 3', 4', 6' or 8' illuminated sections rArticulated joiners between sections r Optional slotted perforated pattern rPrecision die-cast end caps rUL and CUL certified ORDERING INFORMATION SAMPLE NUMBER: 16-DIP-3T5-SC-8D-2EB-DU-RP Series Light Output Mounting Number of Lamps (Not Included) 1 Lamp Type Pendant Run Length Voltage 3 Ballast Switching Options 16=Europa DI=Direct-Indirect I=Indirect P=Pendant 2=2 Lamps 3=3 Lamps T5=T5 T5HO=T5HO T8=T8 SC=Single Cable ST=Single Stem 2 3=3' Luminaire 4=4' Luminaire 6=6' Luminaire 8=8' Luminaire XX=Run Length 1=120V 2=277V 3=347V DB=Dimming Ballast EB=Electronic Ballast (Standard) DU=Double Switching SI=Single Switching Perforation Options BP=None RP=Round SP=Slotted Emergency g y EM=Emergency Pack Fusing g GLR=GLR GMF=GMF NOTES: 1. 16IP is a 2 lamp fixture only; 16DIP is a 3 lamp fixture only. 2. Available with 7° or earthquake 45° swivel canopy assembly. 3. Not all options available. Please consult your Cooper Lighting Representative for availability. MOUNTING INFORMATION 3' Individual 5-5/16" [151mm] 26" [660mm] 36-5/8" [938mm] 6' Individual 5-5/16" [151mm] 4' Individual 5-5/16" [151mm] 38" [965mm] 48-5/8" [1235mm] 8' Individual 62" [1575mm] 88-3/8" [2245mm] 96-5/8" [2454] 72-5/8" [1845] 20' (Typical) 5-5/16" [151mm] 92" [2337mm] 96-5/8" [2454] 5-5/16" [151mm] 98" [2849mm] 96-5/8" [2454] 1-3/8"[35mm] 20' - 5 1/2" [6209mm] 5-5/16" [151mm] 44" [1118mm] 48-5/8" [1235mm] NEO-RAY Specifications and dimensions subject to change without notice. Consult your Cooper Lighting Representative or visit www.cooperlighting.com for available options, accessories and ordering information. Cooper Lighting by Eaton | Product Selection Guide | Sixth Edition | www.cooperlighting.com 9-68 SUSPENDED GEOMETRIC DIRECT FEATURES r Direct pendant stack-light distribution r Contoured louver for vertical illumination r Die-formed 20-gauge steel housing for 3', 4', 6' and 8' sections r Run lengths provided to the nearest foot r Special-ordered and custom-finished housings r UL and CUL certified 5" [127mm] Compliances may not apply to all product configurations. Please consult the product spec sheet for compliance details. COMPLIANCES: UL/cUL Listed - Damp Location, ARRA Compliant, NYC Code Compliant 2S-DP 4" [102mm] ORDERING INFORMATIONΔ SAMPLE NUMBER: 2S-DP-2T8-SL-8'-1EB-SI-S14 Series Light Output Mounting Number of Lamps (Not Included) Lamp Type Pendant Run Length Voltage Ballast 2S=Specialty D=Direct P=Pendant 1=1 Lamp 2=2 Lamps T8=T8 SL=Single Cable ST=Single Stem Overall Nominal Run Length __ ft. 1=120V 2=277V 3=347V DB=Dimming Ballast EB=Electronic Ballast (Standard) Switching Options Emergency Fusing Shielding Options SI=Single Switching EM=Emergency Pack (Consult Factory) GLR=GLR GMF=GMF S14=Contoured Baffle NOTES: Δ Not all options available. Please consult your Cooper Lighting Representative for availability. MOUNTING INFORMATION 5" 26" 5" 5" 36" 38" 5" 48" 5" 62" 5" 5" 72" 86" 5" 96" (Individual fixtures only) Consult factory for continuous run applications TYPICAL STEM LOCATIONS Beginning of run Intermediate fixture 8' BOR - (86") 6' BOR - (62") 4' BOR - (38") 3' BOR - (26") 8' INT - (96") 6' INT - (72") 4' INT - (48") 3' INT - (36") 5" End of run 8' EOR - (96") 6' EOR - (72") 4' EOR - (48") 3' EOR - (36") 5" Overall length of run NEO-RAY SHIELDING OPTIONS S14 Baffle Specifications and dimensions subject to change without notice. Consult your Cooper Lighting Representative or visit www.cooperlighting.com for available options, accessories and ordering information. 9-69 Cooper Lighting by Eaton | Product Selection Guide | Sixth Edition | www.cooperlighting.com 18" [457mm] minimum 8-1/4" [210mm] Compliances may not apply to all product configurations. Please consult the product spec sheet for compliance details. COMPLIANCES: UL/cUL Listed - Damp Location, ARRA Compliant, NYC Code Compliant GEO 14-DIP 6" [153mm] SUSPENDED GEOMETRIC DIRECT-INDIRECT FEATURES rDirect-indirect light distribution rContinuous lighting r Three discrete direct-indirect lighting distribution chambers rDie-formed 20-gauge steel housing for 3', 4', 6' and 8' sections rRigid U-shaped, double-formed trim with 3/8" regress soft-lit edge r Special-ordered and custom-finished housings rRun lengths provided to the nearest foot rAdjoining standard sections create lighting patterns r Four light diffuser options available Δ SAMPLE NUMBER: 14DIP-22T8-SC-24'-1EB-DU-S22 Series Light Output Mounting Number of Lamps Up (Not Included) Number of Lamps Down (Not Included) Lamp Type Pendant Run Length Voltage Ballast 14=Geo DI=Direct-Indirect P=Pendant 1=1 Lamp 2=2 Lamps 1=1 Lamp 2=2 Lamps T5=T5 T5HO=T5HO T8=T8 SC=Single Cable ST=Single Stem 1 Overall Nominal Run Length __ ft. 1=120V 2=277V 3=347V DB=Dimming Ballast EB=Electronic Ballast (Standard) Switching Options Emergency Fusing Shielding Options DU=Double Switching SI=Single Switching EM=Emergency Pack (Consult Factory) GLR=GLR GMF=GMF S22=White Acrylic Diffuser S58=KSH-12 Acrylic Lens S72=Bold Baffle S79=Parabolic Baffle NOTES: Δ Not all options available. Please consult your Cooper Lighting Representative for availability. 1. Available with 7° or earthquake 45° swivel canopy assembly. MOUNTING INFORMATION 5" 26"" 5" 5" 36" 38" 5" 18" 48" 36" 18" 24" 72" 48" 24" 96" (Individual fixtures only) Consult factory for continuous run applications TYPICAL STEM LOCATIONS 24" 48" Typical 8' BOR 24" 8' INT 4' EOR Overall length SHIELDING OPTIONS S58 Acrylic Lens S72 Bold Baffle NEO-RAY S22 Acrylic Diffuser S79 Parabolic Baffle Specifications and dimensions subject to change without notice. Consult your Cooper Lighting Representative or visit www.cooperlighting.com for available options, accessories and ordering information. Cooper Lighting by Eaton | Product Selection Guide | Sixth Edition | www.cooperlighting.com 9-70 SUSPENDED GEOMETRIC DIRECT FEATURES r Direct light distribution r Continuous illumination r Die-formed 20-gauge steel housing for 3', 4', 6' and 8' sections r Rigid U-shaped, double-formed trim with 3/8" regress soft-lit edge r Special-ordered and custom-finished housings r Run lengths provided to the nearest foot r Adjoining standard sections create lighting patterns r Four light diffuser options available 9-1/4" [235mm] minimum 6-1/4" [159mm] Compliances may not apply to all product configurations. Please consult the product spec sheet for compliance details. COMPLIANCES: UL/cUL Listed - Damp Location, ARRA Compliant, NYC Code Compliant 7-3/4" [197mm] 8-3/4" [223mm] GEO 44-DP ORDERING INFORMATION SAMPLE NUMBER: 44DP-2T5-SC-8D-1EB-SI-S22 Series Light Output Mounting Number of Lamps (Not Included) Lamp Type Pendant Run Length Voltage Ballast 44=Geo D=Direct P=Pendant 1=1 Lamp 2=2 Lamps 3=3 Lamps T5=T5 T5HO=T5HO T8=T8 SC=Single Cable ST=Single Stem 1 Overall Nominal Run Length __ ft. 1=120V 2=277V 3=347V DB=Dimming Ballast EB=Electronic Ballast (Standard) Switching Options Emergency Fusing Shielding Options DU=Double Switching SI=Single Switching EM=Emergency Pack (Consult Factory) GLR=GLR GMF=GMF S22=White Acrylic Diffuser S58=KSH-12 Acrylic Lens S72=Bold Baffle S79=Parabolic Baffle NOTES: 1. Available with 7° or earthquake 45° swivel canopy assembly. MOUNTING INFORMATION 5" [127mm] 5 "[127mm] 5" [127mm] 36" & 48" [914mm] & [1219mm] 5" [127mm] 72" & 96" [1829mm] & [2438mm] 86" [2184mm] 96" [2438mm] 48" [1219mm] 20' [6096mm] Illuminated patterns are provided in 1' increments plus 7-1/4" [185mm] 90˚ mitered corner NEO-RAY SHIELDING OPTIONS S22 Acrylic Diffuser S58 Acrylic Lens S72 Bold Baffle S79 Parabolic Baffle Specifications and dimensions subject to change without notice. Consult your Cooper Lighting Representative or visit www.cooperlighting.com for available options, accessories and ordering information. 9-71 Cooper Lighting by Eaton | Product Selection Guide | Sixth Edition | www.cooperlighting.com Compliances may not apply to all product configurations. Please consult the product spec sheet for compliance details. 3-1/2" [89mm] COMPLIANCES: UL/cUL Listed - Damp Location, ARRA Compliant, NYC Code Compliant 9" [229mm] SUSPENDED GEOMETRIC DIRECT-INDIRECT FEATURES rEven direct-indirect light distribution rCompact extruded aluminum housing r Parabolic louver designed for continuous, unbroken appearance rPearlescent low-glare louver finish rSturdy .125" thick aluminum end cap construction r Optional shielding media ORDERING INFORMATION SAMPLE NUMBER: 66DIP-2T8-SC-8D-1EB-SI-S79 Series Light Output Mounting Number of Lamps (Not Included) Lamp Type Pendant Run Length Voltage Ballast 66=Omni DI=Direct-Indirect P=Pendant 1=1 Lamp 2=2 Lamps T5=T5 T5HO=T5HO T8=T8 SC=Single Cable ST=Single Stem 1 Overall Nominal Run Length __ ft. 1=120V 2=277V 3=347V DB=Dimming Ballast EB=Electronic Ballast (Standard) Switching Options Emergency Fusing Shielding Options DU=Double Switching SI=Single Switching EM=Emergency Pack (Consult Factory) GLR=GLR GMF=GMF S58=KSH-12 Acrylic Lens S79=Parabolic Baffle NOTES: 1. Available with 7° or earthquake 45° swivel canopy assembly. MOUNTING INFORMATION 5-1/4" [133mm] 5-1/4" [133mm] 5-1/4" [133mm] 48-1/2" [1232mm] 5-1/4" [133mm] 96-3/4" [2458mm] 86-1/4" [2191mm] 96-1/2" [2451mm] 48-1/4" [1226mm] 5-1/4" [133mm] 20' - 1-1/2" [6134mm] SHIELDING OPTIONS NEO-RAY S58 Acrylic Lens S79 Parabolic Baffle Specifications and dimensions subject to change without notice. Consult your Cooper Lighting Representative or visit www.cooperlighting.com for available options, accessories and ordering information. Cooper Lighting by Eaton | Product Selection Guide | Sixth Edition | www.cooperlighting.com 9-72 SUSPENDED GEOMETRIC INDIRECT FEATURES r Indirect light distribution r Sturdy composition with continuous light r Die-formed 20-gauge steel housing 3', 4', 6', 8' illuminated sections r Rigid U-shaped, double-formed trim with 3/8" regress soft-lit edge r Run lengths provided to the nearest foot r Special-ordered and custom-finished housings r Adjoining standard sections create lighting patterns 27" [686mm] Compliances may not apply to all product configurations. Please consult the product spec sheet for compliance details. 6-1/4" [159mm] COMPLIANCES: UL/cUL Listed - Damp Location, ARRA Compliant, NYC Code Compliant GEO 80-IP 6" [153mm] ORDERING INFORMATION SAMPLE NUMBER: 80IP-2T8-SC-30'-1EB-SI Series Light Output Mounting Number of Lamps (Not Included) Lamp Type Pendant Run Length Voltage 2 Ballast 80=Geo I=Indirect P=Pendant 1=1 Lamp 2=2 Lamps T5=T5 T5HO=T5HO T8=T8 SC=Single Cable ST=Single Stem 1 Overall Nominal Run Length __ ft. 1=120V 2=277V 3=347V DB=Dimming Ballast EB=Electronic Ballast (Standard) Switching Options Emergency Fusing DU=Double Switching SI=Single Switching EM=Emergency Pack (Consult Factory) GLR=GLR GMF=GMF NOTES: 1. Available with 7° or earthquake 45° swivel canopy assembly. 2. Not all options available. Please consult your Cooper Lighting Representative for availability. MOUNTING INFORMATION 96" [2438mm] 48" [1219mm] 1" [26mm] 1" [26mm] 1" [26mm] 1" [26mm] 94" [2388mm] 96" [2438mm] 48" [1219mm] 1" [26mm] 20' [6096mm] Illuminated patterns are provided in 1' increments plus 6" [153mm] NEO-RAY 90˚ butted corner Specifications and dimensions subject to change without notice. Consult your Cooper Lighting Representative or visit www.cooperlighting.com for available options, accessories and ordering information. 9-73 Cooper Lighting by Eaton | Product Selection Guide | Sixth Edition | www.cooperlighting.com 9-1/4" [235mm] 6-1/4" [159mm] Compliances may not apply to all product configurations. Please consult the product spec sheet for compliance details. COMPLIANCES: UL/cUL Listed - Damp Location, ARRA Compliant, NYC Code Compliant 6" [153mm] GEO 83-DP SUSPENDED GEOMETRIC DIRECT FEATURES rDirect light distribution rSturdy composition with continuous light r Die-formed 20-gauge steel housing 3', 4', 6', 8' illuminated sections rRigid U-shaped, double-formed trim with 3/8" regress soft-lit edge rRun lengths provided to the nearest foot r Housings may be special ordered for custom finish rAdjoining standard sections create lighting patterns rFour light diffuser options available ORDERING INFORMATION SAMPLE NUMBER: 83DP-2T8-SC-8D-1EB-SI-S22 Series Light Output Mounting Number of Lamps (Not Included) Lamp Type Pendant Run Length Voltage 2 Ballast 83=Geo D=Direct P=Pendant 1=1 Lamp 2=2 Lamps T5=T5 T5HO=T5HO T8=T8 SC=Single Cable ST=Single Stem 1 Overall Nominal Run Length __ ft. 1=120V 2=277V 3=347V DB=Dimming Ballast EB=Electronic Ballast (Standard) Switching Options Emergency Fusing Shielding Options DU=Double Switching SI=Single Switching EM=Emergency Pack (Consult Factory) GLR=GLR GMF=GMF S22=White Acrylic Diffuser S58=KSH-12 Acrylic Lens S72=Bold Baffle S79=Parabolic Baffle NOTES: 1. Available with 7° or earthquake 45° swivel canopy assembly. 2. Not all options available. Please consult your Cooper Lighting Representative for availability. MOUNTING INFORMATION 5" [127mm] 5 "[127mm] 5" [127mm] 36" & 48" [914mm] & [1219mm] 5" [127mm] 72" & 96" [1829mm] & [2438mm] 96" [2438mm] 86" [2184mm] 48" [1219mm] 20' [6096mm] Illuminated patterns are provided in 1' increments plus 7-1/4" [185mm] 90˚ mitered corner SHIELDING OPTIONS S58 Acrylic Lens S72 Bold Baffle NEO-RAY S22 Acrylic Diffuser S79 Parabolic Baffle Specifications and dimensions subject to change without notice. Consult your Cooper Lighting Representative or visit www.cooperlighting.com for available options, accessories and ordering information. Cooper Lighting by Eaton | Product Selection Guide | Sixth Edition | www.cooperlighting.com 9-74 SUSPENDED GEOMETRIC DIRECT-INDIRECT FEATURES r Direct-indirect light distribution r Sturdy composition with continuous light r Die-formed 20-gauge steel housing 3', 4', 6', 8' illuminated sections r Rigid U-shaped, double-formed trim with 3/8" regress soft-lit edge r Run lengths provided to the nearest foot r Special-ordered and custom-finished housings r Adjoining standard sections create lighting patterns r Four light diffuser options available 18" [457mm] 6-1/4" [159mm] Compliances may not apply to all product configurations. Please consult the product spec sheet for compliance details. COMPLIANCES: UL/cUL Listed - Damp Location, ARRA Compliant, NYC Code Compliant 6" [153mm] GEO 89-DIP ORDERING INFORMATION SAMPLE NUMBER: 89DIP-2T8-SC-8D-1EB-SI-S22 Series Light Output Mounting Number of Lamps (Not Included) Lamp Type Pendant Run Length Voltage 2 Ballast 89=Geo DI=Direct-Indirect P=Pendant 1=1 Lamp 2=2 Lamps T5=T5 T5HO=T5HO T8=T8 SC=Single Cable ST=Single Stem 1 Overall Nominal Run Length __ ft. 1=120V 2=277V 3=347V DB=Dimming Ballast EB=Electronic Ballast (Standard) Switching Options Emergency Fusing Shielding Options DU=Double Switching SI=Single Switching EM=Emergency Pack (Consult Factory) GLR=GLR GMF=GMF S22=White Acrylic Diffuser S58=KSH-12 Acrylic Lens S72=Bold Baffle S79=Parabolic Baffle NOTES: 1. Available with 7° or earthquake 45° swivel canopy assembly. 2. Not all options available. Please consult your Cooper Lighting Representative for availability. MOUNTING INFORMATION 5" [127mm] 5 "[127mm] 5" [127mm] 36" & 48" [914mm] & [1219mm] 5" [127mm] 72" & 96" [1829mm] & [2438mm] 96" [2438mm] 86" [2184mm] 48" [1219mm] 20' [6096mm] Illuminated patterns are provided in 1' increments plus 7-1/4" [185mm] 90˚ mitered corner NEO-RAY SHIELDING OPTIONS S22 Acrylic Diffuser S58 Acrylic Lens S72 Bold Baffle S79 Parabolic Baffle Specifications and dimensions subject to change without notice. Consult your Cooper Lighting Representative or visit www.cooperlighting.com for available options, accessories and ordering information. 9-75 Cooper Lighting by Eaton | Product Selection Guide | Sixth Edition | www.cooperlighting.com SUSPENDED ROUNDS FEATURES rDirect-indirect, angled direct and angled indirect light distribution r Extruded-aluminum housing for 3', 4', 6' and 8' illuminated sections rRun lengths to the nearest foot rSturdy die-cast aluminum end caps r Special-ordered and custom-finished housings rOptional radial louver or acrylic ribbed lens shielding 4DP Compliances may not apply to all product configurations. Please consult the product spec sheet for compliance details. 7" [178mm] minimum ø4" [102mm] COMPLIANCES: UL/cUL Listed - Damp Location, ARRA Compliant, NYC Code Compliant 4ADP 4AIP 4IP CIRQUE 4-AIP, 4-ADP, 4-IP, 4-DP ORDERING INFORMATION SAMPLE NUMBER: 4DP-1T8-SC-8D-1EB-SI-S26 Series Light Output Mounting Number of Lamps (Not Included) Lamp Type Pendant Run Length Voltage 3 Ballast 4=Cirque AD=Angle - Direct AI=Angle - Indirect D=Direct I=Indirect P=Pendant 1=1 Lamp T5=T5 T5HO=T5HO 1 T8=T8 SC=Single Cable ST=Single Stem 2 Overall Nominal Run Length __ ft. 1=120V 2=277V 3=347V DB=Dimming Ballast EB=Electronic Ballast (Standard) Switching Options Emergency Fusing Shielding Options SI=Single Switching EM=Emergency Pack (Consult Factory) GLR=GLR GMF=GMF S14=Contoured Baffle S26=Acrylic Lens NOTES: 1. T5HO Lamping available with S14 louver shielding only. 2. Available with 7° or earthquake 45° swivel canopy assembly. 3. Not all options available. Please consult your Cooper Lighting Representative for availability. MOUNTING INFORMATION Series 4-DP and 4-ADP 5-1/8" [130mm] 5-1/8" [130mm] 36-3/8" & 48-3/8" [924mm] & [1229mm] 5-1/8" [130mm] 5-1/8" [130mm] 72-3/8" & 96-3/8" [1838mm] & [2448mm] 96" [2476mm] 86" [2184mm] 48" [1219mm] Illuminated patterns are provided in 1' increments plus connector 10" x 10" Cross 20' - 0-3/8" [6106mm] 7" x 10" T 7" x 7" Corner Series 4-IP and 4-AIP 7/8" [21mm] 7/8" [21mm] 36-3/8" & 48-3/8" [924mm] & [1229mm] 7/8" [21mm] 86" [2184mm] 7/8" [21mm] 72-3/8" & 96-3/8" [1838mm] & [2448mm] 96" [2476mm] 20' - 0-3/8" [6106mm] 48" [1219mm] Illuminated patterns are provided in 1' increments plus connector 10" x 10" Cross 7" x 10" T 7" x 7" Corner SHIELDING OPTIONS NEO-RAY S26 Acrylic Lens S14 Round Baffle Specifications and dimensions subject to change without notice. Consult your Cooper Lighting Representative or visit www.cooperlighting.com for available options, accessories and ordering information. Cooper Lighting by Eaton | Product Selection Guide | Sixth Edition | www.cooperlighting.com 9-76 SUSPENDED ROUNDS DIRECT-INDIRECT FEATURES r Direct-indirect, angled direct and angled indirect light distribution r Extruded-aluminum housing for 3', 4', 6' and 8' illuminated sections r Run lengths to the nearest foot r Sturdy die-cast aluminum end caps r Special-ordered and custom-finished housings r Optional radial louver or acrylic ribbed lens shielding 6AIP Compliances may not apply to all product configurations. Please consult the product spec sheet for compliance details. COMPLIANCES: UL/cUL Listed - Damp Location, ARRA Compliant, NYC Code Compliant 18" [457mm] minimum ø6" [153mm] 6DP CIRQUE 6-AIP, 6-ADP, 6-IP, 6-DP 6IP 6ADP ORDERING INFORMATION SAMPLE NUMBER: 6DP-2T5-SC-8D-1EB-SI-S26 Series Light Output Mounting Number of Lamps (Not Included) Lamp Type Pendant Run Length Voltage 2 Ballast 6=Cirque AD=Angle - Direct AI=Angle - Indirect D=Direct I=Indirect P=Pendant 1=1 Lamp 2=2 Lamps T5=T5 T5HO=T5HO T8=T8 SC=Single Cable ST=Single Stem 1 Overall Nominal Run Length __ ft. 1=120V 2=277V 3=347V DB=Dimming Ballast EB=Electronic Ballast (Standard) Switching Options Emergency Fusing Shielding Options DU=Double Switching SI=Single Switching EM=Emergency Pack (Consult Factory) GLR=GLR GMF=GMF S14=Contoured Baffle S26=Acrylic Lens NOTES: 1. Available with 7° or earthquake 45° swivel canopy assembly. 2. Not all options available. Please consult your Cooper Lighting Representative for availability. MOUNTING INFORMATION Series 6-DP and 6-ADP 1-1/8" [29mm] 1-1/8" [29mm] 36-3/8" & 48-3/8" [924mm] & [1229mm] 1-1/8" [29mm] 1-1/8" [29mm] 72-3/8" & 96-3/8" [1838mm] & [2448mm] 96" [2438mm] 95" [2413mm] 47" [1194mm] Illuminated patterns are provided in 1' increments plus connector 10" x 10" Cross 20' - 0-3/8" [6350mm] 7" x 10" T-grid 7" x 7" Corner Series 6-IP and 6-AIP 5-1/8" [130mm] 5-1/8" [130mm] 72-3/8" & 96-3/8" [1838mm] & [2448mm] 36-3/8" & 48-3/8" [924mm] & [1229mm] 5-1/8" [130mm] 5-1/8" [130mm] 96" [2438mm] 86" [2184mm] 20' - 0-3/8" [6350mm] 48" [1219mm] Illuminated patterns are provided in 1' increments plus connector 10" x 10" Cross 7" x 10" T-grid 7" x 7" Corner NEO-RAY SHIELDING OPTIONS S26 Acrylic Lens S14 Round Baffle Specifications and dimensions subject to change without notice. Consult your Cooper Lighting Representative or visit www.cooperlighting.com for available options, accessories and ordering information. 9-77 Cooper Lighting by Eaton | Product Selection Guide | Sixth Edition | www.cooperlighting.com Compliances may not apply to all product configurations. Please consult the product spec sheet for compliance details. COMPLIANCES: UL/cUL Listed - Damp Location, ARRA Compliant, NYC Code Compliant 18" [457mm] minimum SUSPENDED ROUNDS DIRECT-INDIRECT 6DIP 2 lamps (1x1) 6DIP 3 lamps (1x2) FEATURES rDirect-indirect light distribution rExtruded-aluminum housing for 3', 4', 6' and 8' illuminated sections r Run lengths to the nearest foot rSturdy die-cast aluminum end caps rSpecial-ordered and custom-finished housings r Optional radial louver or acrylic ribbed lens shielding CIRQUE 6-DIP ø6" [152mm] ORDERING INFORMATION SAMPLE NUMBER: 6DIP-1x1T5-SC-8D-1EB-SI-S26 Series Light Output Mounting Number of Lamps (Not Included) Lamp Type Pendant Run Length Voltage 2 Ballast 6=Cirque DI=Direct-Indirect P=Pendant 1x1=2 Lamps 1x2=3 Lamps T5=T5 T5HO=T5HO T8=T8 SC=Single Cable ST=Single Stem 1 Overall Nominal Run Length __ ft. 1=120V 2=277V 3=347V DB=Dimming Ballast EB=Electronic Ballast (Standard) Switching Options Emergency Fusing Shielding Options DU=Double Switching SI=Single Switching EM=Emergency Pack (Consult Factory) GLR=GLR GMF=GMF S14=Contoured Baffle S26=Acrylic Lens NOTES: 1. Available with 7° or earthquake 45° swivel canopy assembly. 2. Not all options available. Please consult your Cooper Lighting Representative for availability. MOUNTING INFORMATION 3/4" [20mm] 3/4" [20mm] 3/4" [20mm] 39" & 51" [991mm] & [1295mm] 3/4" [20mm] 3/4" [20mm] 75" & 99" [1905mm] & [2515mm] 97-1/2" [2477mm] 97-1/2" [2477mm] 1-1/2 [39mm] 20'-6" [6249mm] Illuminated patterns are provided in 1' increments plus connector 49-1/2" [1258mm] 12" x 12" Cross 9" x 12" T-grid 9" x 9" Corner SHIELDING OPTIONS NEO-RAY S26 Acrylic Lens S14 Round Baffle Specifications and dimensions subject to change without notice. Consult your Cooper Lighting Representative or visit www.cooperlighting.com for available options, accessories and ordering information. Cooper Lighting by Eaton | Product Selection Guide | Sixth Edition | www.cooperlighting.com 9-78 WALL MOUNT DIRECT-INDIRECT Side-mounted box (not by Neo-Ray) FEATURES r Fixed-angle, direct or indirect light distribution r Extruded-aluminum housing for 3', 4', 6' and 8' illuminated sections r Run lengths provided to the nearest foot r Sturdy die-cast aluminum end caps r Special-ordered and custom-finished housings r Optional radial louver or acrylic ribbed lens shielding 4ADW Compliances may not apply to all product configurations. Please consult the product spec sheet for compliance details. 4" [102mm] COMPLIANCES: UL/cUL Listed - Damp Location, ARRA Compliant, NYC Code Compliant CIRQUE 4-AIW, 4-ADW 5" [127mm] ORDERING INFORMATION SAMPLE NUMBER: 4AIW-1T5-56-2EB-SI-S26 Series Light Output Mounting Number of Lamps (Not Included) Lamp Type Run Length Voltage 1 Ballast Switching Options 4=Cirque AD=Angle - Direct AI=Angle - Indirect W=Wall 1=1 Lamp T5=T5 T5HO=T5HO T8=T8 Overall Nominal Run Length __ ft. 1=120V 2=277V 3=347V DB=Dimming Ballast EB=Electronic Ballast (Standard) SI=Single Switching Emergency Fusing Shielding Options EM=Emergency Pack (Consult Factory) GLR=GLR GMF=GMF S14=Contoured Baffle S26=Acrylic Lens NOTES: 1. Not all options available. Please consult your Cooper Lighting Representative for availability. MOUNTING INFORMATION 5-1/8" [130mm] 5-1/8" [130mm] 18-1/8" [460mm] 36-1/4" [921mm] & 48-1/4" [122mm] 18-1/8" [460mm] 24-1/8" [613mm] 24-1/8" [613mm] 96-1/4" [2445mm] 72-1/4" [1835mm] 24-1/8" [613mm] 24-1/8" [613mm] 48" [1219mm] 48" [1219mm] 48" [1219mm] 48" [1219mm] 20' - 1/4" [6102mm] Illuminated patterns are provided in 1' increments plus connector 7" x 7" Corner NEO-RAY SHIELDING OPTIONS S26 Acrylic Lens S14 Round Baffle Specifications and dimensions subject to change without notice. Consult your Cooper Lighting Representative or visit www.cooperlighting.com for available options, accessories and ordering information. 9-79 Cooper Lighting by Eaton | Product Selection Guide | Sixth Edition | www.cooperlighting.com 6ADW 6" [153mm] WALL MOUNT DIRECT-INDIRECT FEATURES rFixed-angle, direct or indirect light distribution rExtruded-aluminum housing for 3', 4', 6' and 8' illuminated sections r Run lengths to the nearest foot rSturdy die-cast aluminum end caps rSpecial-ordered and custom-finished housings r Optional radial louver or acrylic ribbed lens shielding Compliances may not apply to all product configurations. Please consult the product spec sheet for compliance details. COMPLIANCES: UL/cUL Listed - Damp Location, ARRA Compliant, NYC Code Compliant 8" [204mm] CIRQUE 6-AIW, 6-ADW ORDERING INFORMATION SAMPLE NUMBER: 6AIW-1T8-80-1EB-SI-S14 Series Light Output Mounting Number of Lamps (Not Included) Lamp Type Run Length Voltage 1 Ballast Switching Options 6=Cirque AD=Angle - Direct AI=Angle - Indirect W=Wall 1=1 Lamp 2=2 Lamps T5=T5 T5HO=T5HO T8=T8 Overall Nominal Run Length __ ft. 1=120V 2=277V 3=347V DB=Dimming Ballast EB=Electronic Ballast (Standard) DU=Double Switching SI=Single Switching Emergency Fusing Shielding Options EM=Emergency Pack (Consult Factory) GLR=GLR GMF=GMF S14=Contoured Baffle S26=Acrylic Lens NOTES: 1. Not all options available. Please consult your Cooper Lighting Representative for availability. MOUNTING INFORMATION 5-1/8" [130mm] 5-1/8" [130mm] 18-1/8" [460mm] 36-1/4" [921mm] and 48-1/4" [122mm] 18-1/8" [460mm] 24-1/8" [613mm] 24-1/8" [613mm] 96-1/4" [2445mm] 72-1/4" [1835mm] 24-1/8" [613mm] 24-1/8" [613mm] 48" [1219mm] 48" [1219mm] 48" [1219mm] 48" [1219mm] 20' - 1/4" [6102mm] Illuminated patterns are provided in 1' increments plus connector 9" x 9" Corner SHIELDING OPTIONS NEO-RAY S26 Acrylic Lens S14 Round Baffle Specifications and dimensions subject to change without notice. Consult your Cooper Lighting Representative or visit www.cooperlighting.com for available options, accessories and ordering information. Cooper Lighting by Eaton | Product Selection Guide | Sixth Edition | www.cooperlighting.com 9-80 WALL MOUNT DIRECT-INDIRECT FEATURES r Direct-indirect light distribution r Extruded-aluminum housing for 3', 4', 6' and 8' illuminated sections r Run lengths to the nearest foot r Sturdy die-cast aluminum end caps r Special-ordered and custom-finished housings r Optional radial louver or acrylic ribbed lens shielding 6DIW 1 or 2 Lamp 6" [153mm] Compliances may not apply to all product configurations. Please consult the product spec sheet for compliance details. COMPLIANCES: UL/cUL Listed - Damp Location, ARRA Compliant, NYC Code Compliant 8" [204mm] CIRQUE 6-DIW ORDERING INFORMATION SAMPLE NUMBER: 6DIW-3T8-8D-1EB-SI-S26 Series Light Output Mounting Number of Lamps (Not Included) Lamp Type Run Length Voltage 1 Ballast Switching Options 6=Cirque DI=Direct-Indirect W=Wall 1=1 Lamp 2=2 Lamps 3=3 Lamps T5=T5 T5HO=T5HO T8=T8 Overall Nominal Run Length __ ft. 1=120V 2=277V 3=347V DB=Dimming Ballast EB=Electronic Ballast (Standard) DU=Double Switching SI=Single Switching Emergency Fusing Shielding Options EM=Emergency Pack (Consult Factory) GLR=GLR GMF=GMF S14=Contoured Baffle S26=Acrylic Lens NOTES: 1. Not all options available. Please consult your Cooper Lighting Representative for availability. MOUNTING INFORMATION 5-1/8" [130mm] 5-1/8" [130mm] 5-1/8" [130mm] 36-3/8" [924mm] and 48-3/8" [1229mm] 5-1/8" [130mm] 24-1/8" [613mm] 24-1/8" [613mm] 96-3/8" [2448mm] 72-3/8" [1833mm] 24-1/8" [613mm] 24-1/8" [613mm] 48" [1219mm] 48" [1219mm] 48" [1219mm] 48" [1219mm] 20' - 1/4" [6102mm] Illuminated patterns are provided in 1' increments plus connector 9" x 9" Corner NEO-RAY SHIELDING OPTIONS S26 Acrylic Lens S14 Round Baffle Specifications and dimensions subject to change without notice. Consult your Cooper Lighting Representative or visit www.cooperlighting.com for available options, accessories and ordering information. 9-81 Cooper Lighting by Eaton | Product Selection Guide | Sixth Edition | www.cooperlighting.com 8-1/4" [210mm] WALL MOUNT DIRECT-INDIRECT FEATURES rDirect-indirect 50/50 light distribution rDie-formed 20-gauge steel housing for 3', 4', 6' and 8' sections r Discrete direct-indirect lighting for 3 distinct distributions rRigid U-shaped trim with 3/8" regress soft-lit edge rRun lengths provided to the nearest foot r Adjoining standard sections create lighting patterns rVariety of diffuser options available rSpecial-ordered and custom-finished housings Compliances may not apply to all product configurations. Please consult the product spec sheet for compliance details. COMPLIANCES: UL/cUL Listed - Damp Location, ARRA Compliant, NYC Code Compliant GEO 14-DIW 6" [153mm] 1/2" [13mm] ORDERING INFORMATION SAMPLE NUMBER: 14DIW-21T8-24'-1EB-SI-S22 Series Light Output Mounting Number of Lamps Up (Not Included) Number of Lamps Down (Not Included) Lamp Type Run Length Voltage 1 14=Geo DI=Direct-Indirect W=Wall 1=1 Lamp 2=2 Lamps 1=1 Lamp 2=2 Lamps T5=T5 T5HO=T5HO T8=T8 Overall Nominal Run Length __ ft. 1=120V 2=277V 3=347V Ballast Switching Options Emergency Fusing Shielding Options DB=Dimming Ballast EB=Electronic Ballast (Standard) DU=Double Switching SI=Single Switching EM=Emergency Pack (Consult Factory) GLR=GLR GMF=GMF S22=White Acrylic Diffuser S58=KSH-12 Acrylic Lens S72=Bold Baffle S79=Parabolic Baffle NOTES: 1. Not all options available. Please consult your Cooper Lighting Representative for availability. MOUNTING INFORMATION 96" [2438mm] 5" [127mm] 19" [483mm] 19" [483mm] 48" [1219mm] 5" [127mm] 5" [127mm] Illuminated runs are provided in 1' increments plus 6" [152mm] Illuminated runs are provided in 1' increments LEGEND 11/16" diameter K.O’s SHIELDING OPTIONS S58 Acrylic Lens S72 Bold Baffle NEO-RAY S22 Acrylic Diffuser S79 Parabolic Baffle Specifications and dimensions subject to change without notice. Consult your Cooper Lighting Representative or visit www.cooperlighting.com for available options, accessories and ordering information. Cooper Lighting by Eaton | Product Selection Guide | Sixth Edition | www.cooperlighting.com 9-82 WALL MOUNT DIRECT-INDIRECT 16DIW FEATURES r Direct-indirect light distribution r Die-formed 20-gauge steel housing for 3' and 4' illuminated sections r Precision die-cast end caps r Round perforated pattern or optional slotted perforated pattern r One-inch articulated joiners between sections 4" [102mm] Compliances may not apply to all product configurations. Please consult the product spec sheet for compliance details. COMPLIANCES: UL/cUL Listed - Damp Location, ARRA Compliant, NYC Code Compliant 8-3/16" [208mm] EUROPA 16-DIW ORDERING INFORMATION SAMPLE NUMBER: 16DIW-1T8-56-2EB-SI-RP Series Light Output Mounting Number of Lamps (Per Cross Section) Lamp Type Run Length Voltage 1 Ballast 16=Europa DI=Direct-Indirect W=Wall 1=1 Lamp (Not Included) 2=2 Lamps (Not Included) BX40W=BX40W T5=T5 T5HO=T5HO T8=T8 Overall Nominal Run Length __ ft. 1=120V 2=277V 3=347V DB=Dimming Ballast EB=Electronic Ballast (Standard) Switching Options Perforation Emergency Fusing DU=Double Switching SI=Single Switching BP=None RP=Round SP=Slotted EM=Emergency Pack (Consult Factory) GLR=GLR GMF=GMF NOTES: 1. Not all options available. Please consult your Cooper Lighting Representative for availability. MOUNTING INFORMATION 42-3/8" 42-3/8" 18-3/16" 4' INT 1" Articulated joiner 3' EOR NEO-RAY 3' BOR 18-3/16" Specifications and dimensions subject to change without notice. Consult your Cooper Lighting Representative or visit www.cooperlighting.com for available options, accessories and ordering information. 9-83 Cooper Lighting by Eaton | Product Selection Guide | Sixth Edition | www.cooperlighting.com 4" [102mm] S Compliances may not apply to all product configurations. Please consult the product spec sheet for compliance details. WALL MOUNT SEMI-INDIRECT FEATURES rSemi-indirect light distribution rDie-formed 20-gauge steel housing for 3' and 4' illuminated sections r Round perforated pattern or optional slotted perforated pattern rPrecision die-cast end caps rOne-inch articulated joiners between sections COMPLIANCES: UL/cUL Listed - Damp Location, ARRA Compliant, NYC Code Compliant 6-1/8" [156mm] 6-1/2" [165mm] S Slim line ballast only EUROPA 16-IW ORDERING INFORMATION SAMPLE NUMBER: 16IW-1T5-8D-1EB-SI-RP Series Light Output Mounting Number of Lamps (Not Included) Lamp Type Run Length Voltage 1 Ballast Switching Options 16=Europa I=Indirect W=Wall 1=1 Lamp T5=T5 T5HO=T5HO T8=T8 Overall Nominal Run Length __ ft. 1=120V 2=277V DB=Dimming Ballast EB=Electronic Ballast (Standard) SI=Single Switching Perforation Emergency Fusing BP=None RP=Round SP=Slotted EM=Emergency Pack (Consult Factory) GLR=GLR GMF=GMF NOTES: 1. Not all options available. Please consult your Cooper Lighting Representative for availability. MOUNTING INFORMATION 18-3/16" 42-3/8" 42-3/8" 18-3/16" 4' INT 1" Articulated joiner 3' BOR 3' EOR MOUNTING HOLE PATTERN C L 5-5/16" [135mm] C L 1-1/4" [32mm] 3' Row 5-5/16" [135mm] 5-5/16" [135mm] 4' Row 36-5/8" [930mm] 48-5/8" [1235mm] Mounting hole legend 7/8" diameter K.O. 3/8" diameter mounting holes NEO-RAY Specifications and dimensions subject to change without notice. Consult your Cooper Lighting Representative or visit www.cooperlighting.com for available options, accessories and ordering information. Cooper Lighting by Eaton | Product Selection Guide | Sixth Edition | www.cooperlighting.com 9-84 WALL MOUNT SEMI-INDIRECT FEATURES r Semi-indirect light distribution indirect wall luminaire r Die-formed 20-gauge perforated steel housing r Nominal 3', 4', 6' or 8' illuminated sections r Precision die-cast end caps r Articulated joiners between sections r Optional slotted perforated pattern r UL and CUL certified Compliances may not apply to all product configurations. Please consult the product spec sheet for compliance details. 3-3/4" [96mm] S COMPLIANCES: UL/cUL Listed - Damp Location, ARRA Compliant, NYC Code Compliant 6-3/8" [168mm] TRIAD 17-IW S = Slim line ballast only ORDERING INFORMATION SAMPLE NUMBER: 17IW-2T5-8D-1EB-SI-RP Series Light Output Mounting Number of Lamps (Not Included) Lamp Type Run Length Voltage 1 Ballast Switching Options Perforation 17=Triad I=Indirect W=Wall 1=1 Lamp 2=2 Lamps T5=T5 T5HO=T5HO T8=T8 Overall Nominal Run Length __ ft. 1=120V 2=277V DB=Dimming Ballast EB=Electronic Ballast (Standard) DU=Double Switching SI=Single Switching BP=None RP=Round SP=Slotted Emergency Fusing EM=Emergency Pack (Consult Factory) GLR=GLR GMF=GMF NOTES: 1. Not all options available. Please consult your Cooper Lighting Representative for availability. MOUNTING HOLE PATTERN 3' Row C L 4' Row C L 6" [152mm] 1-3/4" [45mm] 3-7/8" [99mm] 15" [381mm] 37-3/4" [959mm] 3-7/8" [99mm] 18" [457mm] 49-3/4" [1264mm] FEED LOCATIONS 9' or 12' Row 38-1/2" [978mm] or 50-1/2" [1283mm] 18-7/8" [479mm] 24-7/8" [632mm] 37-3/4" [959mm] 49-3/4" [1264mm] Feed points 38-1/2" [978mm] or 50 1/2" [1283mm] 18-7/8" [479mm] 24-7/8" [632mm] 1/4" [6mm] 37-3/4" [959mm] 49-3/4" [1264mm] Mounting hole legend 7/8" diameter K.O. 3/8" diameter mounting holes NEO-RAY Overall length of run 37-3/4" [959mm] 49-3/4" [1264mm] Specifications and dimensions subject to change without notice. Consult your Cooper Lighting Representative or visit www.cooperlighting.com for available options, accessories and ordering information. 9-85 Cooper Lighting by Eaton | Product Selection Guide | Sixth Edition | www.cooperlighting.com WALL MOUNT FEATURES rDirect-indirect light distribution rExtruded-aluminum housing for 3', 4', 6' and 8' illuminated sections r Parabolic louver designed for continuous, unbroken appearance rPearlescent low-glare louver finish r.125" thick, sturdy aluminum end caps r Dimming and emergency options rUL and CUL certified 3-1/2" [89mm] Compliances may not apply to all product configurations. Please consult the product spec sheet for compliance details. COMPLIANCES: UL/cUL Listed - Damp Location, ARRA Compliant, NYC Code Compliant 7-7/8" [201mm] OMNI 66-DIW ORDERING INFORMATION SAMPLE NUMBER: 66DIW-1T8-4D-2EB-SI-S79 Series Light Output Mounting Number of Lamps (Not Included) Lamp Type Run Length Voltage 1 Ballast Switching Options Emergency 66=Omni DI=Direct-Indirect W=Wall 1=1 Lamp 2=2 Lamps T8=T8 Overall Nominal Run Length __ ft. 1=120V 2=277V 3=347V DB=Dimming Ballast EB=Electronic Ballast (Standard) DU=Double Switching SI=Single Switching EM=Emergency Pack (Consult Factory) Fusing Shielding Options GLR=GLR GMF=GMF S58=KSH-12 Acrylic Lens S79=Parabolic Baffle NOTES: 1. Not all options available. Please consult your Cooper Lighting Representative for availability. MOUNTING INFORMATION CL 1-1/8" [4mm] 5-5/16" [135mm] 5-5/16" [135mm] Mounting hole legend 7/8" diameter K.O. 3/8" diameter mounting holes 19" [483mm] 19" [483mm] 48-5/8" [1626mm] 10-1/4" [206mm] 5-5/16" [135mm] 38" [965mm] 5-5/16" [135mm] 38" [965mm] 24-5/16" [630mm] 48-1/4" [1226mm] 24-5/16" [630mm] 96-7/8" [2444mm] SHIELDING OPTIONS NEO-RAY S58 Acrylic Lens S79 Parabolic Baffle Specifications and dimensions subject to change without notice. Consult your Cooper Lighting Representative or visit www.cooperlighting.com for available options, accessories and ordering information. Cooper Lighting by Eaton | Product Selection Guide | Sixth Edition | www.cooperlighting.com 9-86 WALL MOUNT INDIRECT FEATURES r Indirect light distribution r Die-formed 20-gauge steel housing 3', 4', 6', 8' illuminated sections r Rigid U-shaped, double-formed trim with 3/8" regress soft-lit edge r Run lengths provided to the nearest foot r Adjoining standard sections create lighting patterns r Special-ordered and custom-finished housings 6-1/4" [159mm] Compliances may not apply to all product configurations. Please consult the product spec sheet for compliance details. COMPLIANCES: UL/cUL Listed - Damp Location, ARRA Compliant, NYC Code Compliant 6" [153mm] 1/2" [13mm] GEO 80-IW ORDERING INFORMATION SAMPLE NUMBER: 80IW-2T8-8D-1EB-SI Series Light Output Mounting Number of Lamps (Not Included) Lamp Type Run Length Voltage 1 Ballast Switching Options Emergency 80=Geo I=Indirect W=Wall 1=1 Lamp 2=2 Lamps T5=T5 T5HO=T5HO T8=T8 Overall Nominal Run Length __ ft. 1=120V 2=277V 3=347V DB=Dimming Ballast EB=Electronic Ballast (Standard) DU=Double Switching SI=Single Switching EM=Emergency Pack (Consult Factory) Fusing GLR=GLR GMF=GMF NOTES: 1. Not all options available. Please consult your Cooper Lighting Representative for availability. MOUNTING INFORMATION 6" [152mm] 6" [152mm] 30" [762mm] 30" [762mm] 6" [152mm] 72" [1829mm] 36" & 48" [914mm] and [1219mm] 90˚ butted corner 6" [152mm] 42" [1067mm] 42" [1067mm] Illuminated patterns are provided in 1' increments plus 6" Consult factory for continuous run mounting box locations 96" [2438mm] NEO-RAY SHIELDING OPTIONS S22 Acrylic Diffuser S58 Acrylic Lens S72 Bold Baffle S79 Parabolic Baffle Specifications and dimensions subject to change without notice. Consult your Cooper Lighting Representative or visit www.cooperlighting.com for available options, accessories and ordering information. 9-87 Cooper Lighting by Eaton | Product Selection Guide | Sixth Edition | www.cooperlighting.com 6-1/4" [159mm] WALL MOUNT DIRECT FEATURES rDirect light distribution rDie-formed 20-gauge steel housing 3', 4', 6', 8' illuminated sections r Rigid U-shaped, double-formed trim with 3/8" regress soft-lit edge rRun lengths provided to the nearest foot rAdjoining standard sections create lighting patterns r Four light diffuser options available rSpecial-ordered and custom-finished housings Compliances may not apply to all product configurations. Please consult the product spec sheet for compliance details. COMPLIANCES: UL/cUL Listed - Damp Location, ARRA Compliant, NYC Code Compliant 6" [153mm] 1/2" [13mm] GEO 83-DW ORDERING INFORMATION SAMPLE NUMBER: 83DW-2T8-4D-1EB-SI-S22 Series Light Output Mounting Number of Lamps (Not Included) Lamp Type Run Length Voltage 1 Ballast Switching Options Emergency 83=Geo D=Direct W=Wall 1=1 Lamp 2=2 Lamps T5=T5 T5HO=T5HO T8=T8 Overall Nominal Run Length __ ft. 1=120V 2=277V 3=347V DB=Dimming Ballast EB=Electronic Ballast (Standard) DU=Double Switching SI=Single Switching EM=Emergency Pack (Consult Factory) Shielding Options S22=White Acrylic Diffuser S58=KSH-12 Acrylic Lens S72=Bold Baffle S79=Parabolic Baffle NOTES: 1. Not all options available. Please consult your Cooper Lighting Representative for availability. MOUNTING INFORMATION 6" [152mm] 6" [152mm] 6" [152mm] 6" [152mm] 30" [762mm] 30" [762mm] 36" and 48" [914mm] and [1219mm] 72" [1829mm] 90˚ mitered corner 6" [152mm] 6" [152mm] 42" [1067mm] 42" [1067mm] Illuminated patterns are provided in 1' increments plus 7-3/4" Consult factory for continuous run mounting box locations 96" [2438mm] SHIELDING OPTIONS S58 Acrylic Lens S72 Bold Baffle NEO-RAY S22 Acrylic Diffuser S79 Parabolic Baffle Specifications and dimensions subject to change without notice. Consult your Cooper Lighting Representative or visit www.cooperlighting.com for available options, accessories and ordering information. Cooper Lighting by Eaton | Product Selection Guide | Sixth Edition | www.cooperlighting.com 9-88 WALL MOUNT DIRECT-INDIRECT FEATURES r Direct-indirect light distribution (70/30) r Die-formed 20-gauge steel housing 3', 4', 6', 8' illuminated sections r Rigid U-shaped, double-formed trim with 3/8" regress soft-lit edge r Run lengths provided to the nearest foot r Adjoining standard sections create lighting patterns r Four light diffuser options available r Special-ordered and custom-finished housings 6-1/4" [159mm] Compliances may not apply to all product configurations. Please consult the product spec sheet for compliance details. COMPLIANCES: UL/cUL Listed - Damp Location, ARRA Compliant, NYC Code Compliant 6" [153mm] GEO 89-DIW 1/2" [13mm] ORDERING INFORMATION SAMPLE NUMBER: 89DIW-2T8-4D-1EB-SI-S22 Series Light Output Mounting Number of Lamps (Not Included) Lamp Type Run Length Voltage 1 Ballast Switching Options Emergency 89=Geo DI=Direct-Indirect W=Wall 1=1 Lamp 2=2 Lamps T5=T5 T5HO=T5HO T8=T8 Overall Nominal Run Length __ ft. 1=120V 2=277V 3=347V DB=Dimming Ballast EB=Electronic Ballast (Standard) DU=Double Switching SI=Single Switching EM=Emergency Pack (Consult Factory) Fusing Shielding Options GLR=GLR GMF=GMF S22=White Acrylic Diffuser S58=KSH-12 Acrylic Lens S72=Bold Baffle S79=Parabolic Baffle NOTES: 1. Not all options available. Please consult your Cooper Lighting Representative for availability. MOUNTING INFORMATION 6" [152mm] 6" [152mm] 6" [152mm] 6" [152mm] 30" [762mm] 30" [762mm] 36" and 48" [914mm] and [1219mm] 72" [1829mm] 90˚ mitered corner 6" [152mm] 6" [152mm] 42" [1067mm] 42" [1067mm] Illuminated patterns are provided in 1' increments plus 7-3/4" Consult factory for continuous run mounting box locations 96" [2438mm] NEO-RAY SHIELDING OPTIONS S22 Acrylic Diffuser S58 Acrylic Lens S72 Bold Baffle S79 Parabolic Baffle Specifications and dimensions subject to change without notice. Consult your Cooper Lighting Representative or visit www.cooperlighting.com for available options, accessories and ordering information. 9-89 Cooper Lighting by Eaton | Product Selection Guide | Sixth Edition | www.cooperlighting.com 2-1/2" [63mm] S 7-7/8" [200mm] Compliances may not apply to all product configurations. Please consult the product spec sheet for compliance details. S = Slim line ballast only COMPLIANCES: UL/cUL Listed - Damp Location, ARRA Compliant, NYC Code Compliant WALL MOUNT SEMI-INDIRECT FEATURES rSemi-indirect light distribution rModular housing lengths of 4' and 8' for individual or continuous runs r Die-formed steel perforated housings rPrecision die-cast end caps rAdjustable mounting block for accurate leveling SHELL II 201-IW ORDERING INFORMATION SAMPLE NUMBER: 201IW-SP-1N5-1C-120-SU-WA-24 Series =Shell II Optics Up Optics Down Number of Lamps (Not Included) Lamp Type Number of Circuits 2 Wiring 2 Voltage 2 Suspension Run Length S=Specular P=Perforated 1=1 Lamp 2=2 Lamps N5=N5 Normal Output T5=T5 High Output T8=T8 Normal Output 1 1=1 Circuit 2=2 Circuits (Side by Side) B=Battery Pack C=Standard Circuit D=Dimming E=Emergency T=Nightlight Y=Daylight 120=120V 277=277V 347=347V UNV=Universal (120V-277V) SU-WA= Surface/Wall Mount Continuously Mounted= Standard row configurations over 8' consist of 4' and 8' sections Individually Mounted= Luminaires may be 4' or 8' in length NOTES: 1. Available with 1 lamp only. 2. Not all options available. Please consult your Cooper Lighting Representative for availability. END CAP STANDARD LUMINAIRE LENGTHS* 48"[1219mm]* 2-1/2" [64mm] 96"[2438mm]* *Dimensions do not include end caps 7-1/8" [181mm] 1-1/4" [38mm] NEO-RAY Specifications and dimensions subject to change without notice. Consult your Cooper Lighting Representative or visit www.cooperlighting.com for available options, accessories and ordering information. Cooper Lighting by Eaton | Product Selection Guide | Sixth Edition | www.cooperlighting.com 9-90 WALL MOUNT SEMI-INDIRECT FEATURES r Semi-indirect light distribution r Fully perforated and illuminated die-formed 20-gauge steel housing r Nominal 4' long fully illuminated sections r Precision die-cast end caps r Articulated joiners space fixtures 1/4" apart when mounted in rows r Dimming and emergency options r UL and CUL certified 3-1/2" [89mm] 8-1/2" [216mm] Compliances may not apply to all product configurations. Please consult the product spec sheet for compliance details. COMPLIANCES: UL/cUL Listed - Damp Location, ARRA Compliant, NYC Code Compliant NUAGE 301-IW ORDERING INFORMATION SAMPLE NUMBER: 301IW-1BX40W-48-2EB-SI-RP Series Light Output Mounting Number of Lamps (Not Included) Lamp Type Run Length Voltage 1 Ballast Switching Options Perforation 301=Nuage I=Indirect W=Wall 1=1 Lamp BX40W=BX40W BX50W=BX50W Overall Nominal Run Length __ ft. 1=120V 2=277V 3=347V DB=Dimming Ballast EB=Electronic Ballast (Standard) SI=Single Switching RP=Round SP=Slotted Emergency Fusing EM=Emergency Pack (Consult Factory) GLR=GLR GMF=GMF NOTES: 1. Not all options available. Please consult your Cooper Lighting Representative for availability. MOUNTING HOLE PATTERN C L 2-1/2" [64mm] 1-1/8" [29mm] 2-1/2" [64mm] 3-1/4"[83mm] 2" [51mm] 18" [457mm] FEED LOCATIONS 23-1/2" [597mm] 3" [77mm] 47" [1194mm] Housing 18" [457mm] Mounting hole legend 7/8" diameter K.O. 3/8" diameter mounting holes Feed points 47-1/4" [1200mm] 47-1/4" [1200mm] 23-1/2" [597mm] 1/4" [32mm] 47" [1194mm] Overall length of run NEO-RAY 47" [1194mm] Specifications and dimensions subject to change without notice. Consult your Cooper Lighting Representative or visit www.cooperlighting.com for available options, accessories and ordering information. 9-91 Cooper Lighting by Eaton | Product Selection Guide | Sixth Edition | www.cooperlighting.com S 3-1/64" [17mm] 1/8" [3mm] 9" [229mm] WALL MOUNT DIRECT-INDIRECT FEATURES rDirect-indirect light distribution rDie-formed 20-gauge perforated steel housing r Direct, indirect and direct-indirect light distributions rNominal 3' and 4' illuminated sections rPrecision die-cast end caps r Optional slotted perforated pattern rArticulated joiners between sections rUL and CUL certified S = Slim line ballast only Compliances may not apply to all product configurations. Please consult the product spec sheet for compliance details. COMPLIANCES: UL/cUL Listed - Damp Location, ARRA Compliant, NYC Code Compliant PETITE NUAGE 302-DIW ORDERING INFORMATION SAMPLE NUMBER: 302IW-2T5-4D-1EB-SI-RP Series Light Output Mounting Number of Lamps (Not Included) Lamp Type Run Length Voltage 1 Ballast Switching Options Perforation 302=Nuage DI=Direct-Indirect W=Wall 2=2 Lamps T5=T5 T5HO=T5HO T8=T8 Overall Nominal Run Length __ ft. 1=120V 2=277V DB=Dimming Ballast EB=Electronic Ballast (Standard) DU=Double Switching SI=Single Switching BP=None RP=Round SP=Slotted Emergency Fusing EM=Emergency Pack (Consult Factory) GLR=GLR GMF=GMF NOTES: 1. Not all options available. Please consult your Cooper Lighting Representative for availability. MOUNTING INFORMATION Typical run detail Articulated joiner 1" 1" 49-3/4" 49-3/4" 49-3/4" Overall length of run Typical mounting locations 4-3/8" 41" 50-1/4" Mounting 9-3/4" 41" 50-3/4" 4-3/8" 41" 49-3/4" Overall length of run NEO-RAY Specifications and dimensions subject to change without notice. Consult your Cooper Lighting Representative or visit www.cooperlighting.com for available options, accessories and ordering information. Cooper Lighting by Eaton | Product Selection Guide | Sixth Edition | www.cooperlighting.com 9-92 WALL MOUNT SEMI-INDIRECT FEATURES r Semi-indirect light distribution r Minimalist fixture profile of 6.75" wide by 2.25" high r Die-formed 20-gauge perforated steel housing r 4' and 8' sections for individual or continuous runs r Precision die-cast end caps r UL and CUL certified 2-1/4" [57mm] S 6-3/4" [171mm] Compliances may not apply to all product configurations. Please consult the product spec sheet for compliance details. COMPLIANCES: UL/cUL Listed - Damp Location, ARRA Compliant, NYC Code Compliant 8-1/8" [206mm] S = Slim line ballast only VICEROY 501-IW ORDERING INFORMATION SAMPLE NUMBER: 501IW-SP-2T5-20-1EB-SI-RP Series Light Output Mounting Number of Lamps (Not Included) Lamp Type Run Length Voltage 1 Ballast Switching Options Perforation 501=Viceroy I=Indirect W=Wall 1=1 Lamp 2=2 Lamps T5=T5 T5HO=T5HO Overall Nominal Run Length __ ft. 1=120V 2=277V DB=Dimming Ballast EB=Electronic Ballast (Standard) DU=Double Switching SI=Single Switching BP=None RP=Round SP=Slotted Emergency Fusing EM=Emergency Pack (Consult Factory) GLR=GLR GMF=GMF NOTES: 1. Not all options available. Please consult your Cooper Lighting Representative for availability. END CAP MOUNTING AND FEED HOLE LOCATIONS 13-3/4" 25-3/4" 24" 48" 24" 48" 24" 48" 4' or 8' INT 24" 48" 4' or 8' INT 13-3/4" 25-3/4" 4' or 8' INT 48" 96" 49-3/4" 97-3/4" 24" 48" 49-3/4" 97-3/4" 1-1/4" [32mm] MOUNTING BRACKET LOCATIONS 13-3/4" 24" 13-3/4" 25-3/4" 48" 51-1/2" 99-1/2" MODULAR ROW CONFIGURATION STANDARD LUMINAIRE LENGTHS " ! " " 48" (1219mm) NEO-RAY 25-3/4" 12' Row 96" (2438mm) 48" mounting 96" mounting 20' Row Specifications and dimensions subject to change without notice. Consult your Cooper Lighting Representative or visit www.cooperlighting.com for available options, accessories and ordering information. 9-93 Cooper Lighting by Eaton | Product Selection Guide | Sixth Edition | www.cooperlighting.com 1-5/8" [41mm] S 8-3/4" [222mm] 10-1/4" [260.25mm] WALL MOUNT SEMI-INDIRECT FEATURES rSemi-indirect light distribution rCompact fixture profile of 8.75" wide and 1.625" high r Optimized T5 optics for wide light distribution and high efficiency rDie-formed 20-gauge perforated steel housing rModular 4' and 8' sections for individual or continuous runs r Standard or tapered precision die-cast end caps rDimming and emergency options rUL and CUL certified 2" Perforation Window Compliances may not apply to all product configurations. Please consult the product spec sheet for compliance details. S = Slim line ballast only COMPLIANCES: UL/cUL Listed - Damp Location, ARRA Compliant, NYC Code Compliant NIMBUS I 601-IW ORDERING INFORMATION SAMPLE NUMBER: 601IW-1T5HO-40-1EB-SI-RP-ET Series Light Output Mounting Number of Lamps (Not Included) Lamp Type Run Length Voltage 1 Ballast Switching Options Perforation 601=Nimbus I=Indirect W=Wall 1=1 Lamp 2=2 Lamps T5=T5 T5HO=T5HO Overall Nominal Run Length __ ft. 1=120V 2=277V DB=Dimming Ballast EB=Electronic Ballast (Standard) DU=Double Switching SI=Single Switching BP=None RP=Round Emergency End Cap EM=Emergency Pack (Consult Factory) ES=Straight ET=Tapered NOTES: 1. Not all options available. Please consult your Cooper Lighting Representative for availability. MOUNTING INFORMATION END CAP “ES” (Straight - standard) Run Lay-out Feed location End cap - side view Overall length of run 48" 96" 4-1/4" 48" 96" 4-1/4" 6" [152mm] 52-1/4" 100-1/4" END CAP “ET” (Tapered) 52-1/4" 100-1/4" End cap - side view 48" 96" 4-1/4" 4-1/4" 4-1/4" [108mm] 56-1/2" 104-1/2" MODULAR ROW CONFIGURATION STANDARD LUMINAIRE LENGTHS " ! " " 48" (1219mm) 96" (2438mm) 96" mounting NEO-RAY 12' Row 48" mounting 20' Row Specifications and dimensions subject to change without notice. Consult your Cooper Lighting Representative or visit www.cooperlighting.com for available options, accessories and ordering information. Cooper Lighting by Eaton | Product Selection Guide | Sixth Edition | www.cooperlighting.com 9-94 WALL MOUNT SEMI-INDIRECT FEATURES r Semi-indirect light distribution indirect wall luminaire r Minimalist fixture profile of 5.75" wide by 1.75" high r Die-formed 20-gauge perforated steel housing r Standard 4' and 8' fixture lengths for individual or continuous runs r Precision die-cast end caps r UL and CUL certified S 1-3/4" [44mm] 2" [51mm] Compliances may not apply to all product configurations. Please consult the product spec sheet for compliance details. 5-3/4" [146mm] COMPLIANCES: UL/cUL Listed - Damp Location, ARRA Compliant, NYC Code Compliant S = Slim line ballast only TWIN BEAM 611-IW ORDERING INFORMATION SAMPLE NUMBER: 611IW-1T5-8D-1EB-SI-RP Series Light Output Mounting Number of Lamps (Not Included) Lamp Type Run Length Voltage 1 Ballast Switching Options Perforation 611=Twin Beam I=Indirect W=Wall 1=1 Lamp T5=T5 T5HO=T5HO Overall Nominal Run Length __ ft. 1=120V 2=277V DB=Dimming Ballast EB=Electronic Ballast (Standard) SI=Single Switching BP=None RP=Round SP=Slotted Emergency Fusing EM=Emergency Pack (Consult Factory) GLR=GLR GMF=GMF NOTES: 1. Not all options available. Please consult your Cooper Lighting Representative for availability. END CAP MOUNTING AND FEED HOLE LOCATIONS 13-3/4" 25-3/4" 24" 48" 24" 48" 24" 48" 4' or 8' INT 4' or 8' INT 49-3/4" 97-3/4" 48" 96" 24" 48" 24" 48" 13-3/4" 25-3/4" 4' or 8' INT 49-3/4" 97-3/4" NEO-RAY 1-1/4" [32mm] MODULAR ROW CONFIGURATION STANDARD LUMINAIRE LENGTHS " ! " " 48" (1219mm) 12' Row 96" (2438mm) 48" mounting 96" mounting 20' Row Specifications and dimensions subject to change without notice. Consult your Cooper Lighting Representative or visit www.cooperlighting.com for available options, accessories and ordering information. 9-95 Cooper Lighting by Eaton | Product Selection Guide | Sixth Edition | www.cooperlighting.com 2-1/2" [63mm] 7" [177mm] WALL MOUNT SEMI-INDIRECT FEATURES rSemi-indirect light distribution rT5 and T8 lamping options r Die-formed 20-gauge perforated steel housing rModular 4' and 8' sections for individual or continuous runs rPrecision die-cast end caps r Adjustable mounting block for accurate leveling rDimming and emergency options rUL and CUL certified Compliances may not apply to all product configurations. Please consult the product spec sheet for compliance details. COMPLIANCES: UL/cUL Listed - Damp Location, ARRA Compliant, NYC Code Compliant NIMBUS II 701-IW ORDERING INFORMATION SAMPLE NUMBER: 701IW-SP-1T5HO-1C-1-SU-WA-24 Series Optics Up Optics Down Number of Lamps (Not Included) Lamp Type Number of Circuits 1 Wiring 1 Voltage 1 Suspension 701IW=Nimbus II Wall Mount S=Specular P=Perforated 1=1 Lamp 2=2 Lamps N5=N5 Normal Output T5=T5 High Output T8=T8 1=1 Circuit 2=2 Circuits (Side by Side) B=Battery Pack C=Standard Circuit D=Dimming E=Emergency T=Nightlight Y=Daylight 120=120V 277=277V 347=347V UNV=Universal (120V-277V) SU-WA=Surface/Wall Mount Run Length Continuously Mounted=Standard row configurations over 8' consist of 4' and 8' sections Individually Mounted=Luminaires may be 4' or 8' in length NOTES: 1. Due to various constraints, some options may not be combined with others. Please consult your Cooper Lighting Representative for availability. END CAP 2-1/2" [64mm] 7-1/8" [181mm] 5" [127mm] MODULAR ROW CONFIGURATION STANDARD LUMINAIRE LENGTHS " ! " " 48" (1219mm) 96" (2438mm) 96" mounting NEO-RAY 12' Row 48" mounting 20' Row Specifications and dimensions subject to change without notice. Consult your Cooper Lighting Representative or visit www.cooperlighting.com for available options, accessories and ordering information. Cooper Lighting by Eaton | Product Selection Guide | Sixth Edition | www.cooperlighting.com 9-96 SURFACE DIRECT FEATURES r Direct surface mounted stack-light distribution r Contoured louver for vertical illumination r Die-formed 20-gauge steel housing for 3', 4', 6' and 8' sections r Run lengths provided to the nearest foot r Special-ordered and custom-finished housings r UL and CUL certified 5" [127mm] Compliances may not apply to all product configurations. Please consult the product spec sheet for compliance details. COMPLIANCES: UL/cUL Listed - Damp Location, ARRA Compliant, NYC Code Compliant 2S-DS 4" [102mm] ORDERING INFORMATION SAMPLE NUMBER: 2S-DS-1T8-16'-1EB-SI-S14 Series Light Output Mounting Number of Lamps (Not Included) Lamp Type Run Length Voltage 1 Ballast Switching Options Emergency 2S=Specialty D=Direct S=Surface 1=1 Lamp 2=2 Lamps T5=T5 T5HO=T5HO T8=T8 Overall Nominal Run Length __ ft. 1=120V 2=277V 3=347V DB=Dimming Ballast EB=Electronic Ballast (Standard) DU=Double Switching SI=Single Switching EM=Emergency Pack (Consult Factory) Fusing Shielding Options GLR=GLR GMF=GMF S14=Contoured Baffle NOTES: 1. Not all options available. Please consult your Cooper Lighting Representative for availability. MOUNTING Top hole data 7/8" diameter KO 5" 26" 5" 5" 5" 38" 1-1/4" 1-1/4" CL CL 36" 48" 5" 36" 13" 1-1/4" 13" 1-1/4" 72" 5" 5" 48" 19" 1-1/4" 19" 5" 1-1/4" 96" (Individual fixtures only) consult factory for continuous run applications NEO-RAY SHIELDING OPTIONS S14 Baffle Specifications and dimensions subject to change without notice. Consult your Cooper Lighting Representative or visit www.cooperlighting.com for available options, accessories and ordering information. 9-97 Cooper Lighting by Eaton | Product Selection Guide | Sixth Edition | www.cooperlighting.com 6-1/4" [159mm] SURFACE DIRECT FEATURES rSurface-mounted direct light distribution rDie-formed 20-gauge steel housing for 3', 4', 6' and 8' sections r Run lengths provided to the nearest foot rSelection of multiple diffuser options rRigid U-shaped, double-formed trim with 3/8" regress soft-lit edge r Special-ordered and custom-finished housings Compliances may not apply to all product configurations. Please consult the product spec sheet for compliance details. COMPLIANCES: UL/cUL Listed - Damp Location, ARRA Compliant, NYC Code Compliant 7-3/4" [197mm] 1/2" [13mm] 8-3/4" [223mm] GEO 44-DS ORDERING INFORMATION SAMPLE NUMBER: 44DS-2T8-20'-UEB-SI-S79 Series Light Output Mounting Number of Lamps (Not Included) Lamp Type Run Length Voltage 1 Ballast Switching Options 44=Geo D=Direct S=Surface 1=1 Lamp 2=2 Lamps 3=3 Lamps T5=T5 T5HO=T5HO T8=T8 XX=Overall Nominal Run Length __ ft. (Any combination of 8', 6', 4' and 3' sections) 1=120V 2=277V 3=347V U=Universal (120-277V) DB=Dimming Ballast EB=Electronic Ballast (Standard) DU=Double Switching SI=Single Switching Emergency Fusing Shielding Options EM=Emergency Pack (Consult Factory) GLR=GLR GMF=GMF S22=White Acrylic Diffuser with Mullions S58=KSH-12 Clear Acrylic Prismatic Lens with Mullions S72=White Bold Baffle S79=Semi-Specular Aluminum Parabolic Baffle NOTES: 1. Due to various constraints, some options may not be combined with others. Please consult your Cooper Lighting Representative for availability. MOUNTING INFORMATION 5" [127mm] 5 "[127mm] 5" [127mm] 36" and 48" [914mm] and [1219mm] 5" [127mm] 72" and 96" [1829mm] and [2438mm] 96" [2438mm] 86" [2184mm] 48" [1219mm] 20' [6096mm] Illuminated patterns are provided in 1' increments plus 7-1/4" [185mm] 90˚mitered corner SHIELDING OPTIONS S58 Acrylic Lens S72 Bold Baffle NEO-RAY S22 Acrylic Diffuser S79 Parabolic Baffle Specifications and dimensions subject to change without notice. Consult your Cooper Lighting Representative or visit www.cooperlighting.com for available options, accessories and ordering information. Cooper Lighting by Eaton | Product Selection Guide | Sixth Edition | www.cooperlighting.com 9-98 SURFACE DIRECT FEATURES r Direct light distribution r Sturdy extruded aluminum 4' and 8' illuminated sections r Parabolic louver designed for continuous, unbroken appearance r Pearlescent low-glare louver finish r .125" thick, sturdy aluminum end caps r Two shielding options 3-1/2" [89mm] 9" [229mm] Compliances may not apply to all product configurations. Please consult the product spec sheet for compliance details. COMPLIANCES: UL/cUL Listed - Damp Location, ARRA Compliant, NYC Code Compliant OMNI 66-DS ORDERING INFORMATION SAMPLE NUMBER: 66DS-1T8-16'-1EB-SI-S79 Series Light Output Mounting Number of Lamps (Not Included) Lamp Type Run Length Voltage 1 Ballast Switching Options Emergency 66=Omni D=Direct S=Surface 1=1 Lamp 2=2 Lamps T5=T5 T5HO=T5HO T8=T8 Overall Nominal Run Length __ ft. 1=120V 2=277V 3=347V DB=Dimming Ballast EB=Electronic Ballast (Standard) DU=Double Switching SI=Single Switching EM=Emergency Pack (Consult Factory) Fusing Shielding Options GLR=GLR GMF=GMF S58=KSH-12 Acrylic Lens S79=Parabolic Baffle NOTES: 1. Not all options available. Please consult your Cooper Lighting Representative for availability. MOUNTING INFORMATION 8' 6' 1-1/8" [29mm] 5-1/4" [133mm] 86-1/4" [2191mm] 5-1/4" [133mm] 62-1/4" [1581mm] 1/8" [29mm] End plate 96-1/2" [2451mm] 1/8" [29mm] End plate 72-1/2" [1842mm] 96-3/4" [2458mm] 4' 3' 5-1/4" [133mm] 1/8" [29mm] End plate 72-3/4" [1848mm] 5-1/4" [133mm] 38" [965mm] 48-1/4" [1226mm] 1/8" [29mm] End plate 48-1/2" [1232mm] 26" [660mm] 36-1/4" [926mm] 36-1/2" [927mm] 7/8" [22mm] hole (Individual fixtures only) Consult factory for continuous run applications NEO-RAY SHIELDING OPTIONS S58 Acrylic Lens S79 Parabolic Baffle Specifications and dimensions subject to change without notice. Consult your Cooper Lighting Representative or visit www.cooperlighting.com for available options, accessories and ordering information. 9-99 Cooper Lighting by Eaton | Product Selection Guide | Sixth Edition | www.cooperlighting.com SURFACE DIRECT FEATURES rDirect light distribution surface mounted rDie-formed 20-gauge steel housing in 3', 4', 6' and 8' sections r Rigid U-shaped, double-formed trim with 3/8" regress soft-lit edge rRuns available to the nearest foot rSeveral shielding options available r Housings may be special ordered for custom finish 6-1/4" [159mm] Compliances may not apply to all product configurations. Please consult the product spec sheet for compliance details. COMPLIANCES: UL/cUL Listed - Damp Location, ARRA Compliant, NYC Code Compliant 6" [153mm] GEO 83-DS ORDERING INFORMATION SAMPLE NUMBER: 83DS-1T8-16'-UEB-SI-S79 Series Light Output Mounting Number of Lamps (Not Included) Lamp Type Run Length Voltage 1 Ballast Switching Options Emergency 83=Geo D=Direct S=Surface 1=1 Lamp 2=2 Lamps T5=T5 T5HO=T5HO T8=T8 XX=Overall Nominal Run Length __ ft. (Any combination of 8', 6', 4', and 3' sections) 1=120V 2=277V 3=347V U=Universal (120-277V) DB=Dimming Ballast EB=Electronic Ballast (Standard) DU=Double Switching SI=Single Switching EM=Emergency Pack (Consult Factory) Fusing Shielding Options GLR=GLR GMF=GMF S22=White Acrylic Diffuser with mullions S58=KSH-12 Clear Acrylic Prismatic Lens with mullions S72=White Bold Baffle S79=Semi-Specular Aluminum Parabolic Baffle NOTES: 1. Due to various constraints, some options may not be combined with others. Please consult your Cooper Lighting Representative for availability. MOUNTING INFORMATION Mounting hole legend 3' and 4' sections 5" [127mm] 7/8" diameter K.O. 72" [1829mm] 96" [2438mm] 5" [127mm] 11/16" x 2" K.O. 3" x 11/16" triple K.O. 36" [914mm] 48" [1219mm] 19" [483mm] 5" [127mm] 19" [483mm] 5" [127mm] SHIELDING OPTIONS S58 Acrylic Lens S72 Bold Baffle NEO-RAY S22 Acrylic Diffuser S79 Parabolic Baffle Specifications and dimensions subject to change without notice. Consult your Cooper Lighting Representative or visit www.cooperlighting.com for available options, accessories and ordering information. Cooper Lighting by Eaton | Product Selection Guide | Sixth Edition | www.cooperlighting.com 9-100 Featuring the newest Neo-Ray products launched since April 2012. NEO-RAY NEW PRODUCT – TABLE OF CONTENTS New Products Section 9-101 Cooper Lighting by Eaton | Product Selection Guide | Sixth Edition | www.cooperlighting.com 23DR LED Straight and Narrow Page 9-103 23DP LED Straight and Narrow Page 9-104 23DS LED Straight and Narrow Page 9-105 23DW LED Straight and Narrow Page 9-106 22DIP LED Straight and Narrow Page 9-107 23DIP LED Straight and Narrow Page 9-107 22DIW Straight and Narrow Page 9-108 23DIW Straight and Narrow Page 9-108 SUSPENDED 22IW LED Straight and Narrow Page 9-109 23IW LED Straight and Narrow Page 9-109 Index Page 9-110 NEW PRODUCT – TABLE OF CONTENTS STRAIGHT & NARROW NEO-RAY Cooper Lighting by Eaton | Product Selection Guide | Sixth Edition | www.cooperlighting.com 9-102 NEW PRODUCTS FEATURES r Extruded aluminum housing in 2', 3', 4', 6' or 8' illuminated sections r High transmisson and opal lens options in lay in and snap in shapes r Durable, low-gloss, white, powder-coated acrylic finish r Individual fixtures or run configurations r Two LED light levels r Available in three CCT options: 3000K, 3500K and 4000K r 120-277 voltage electronic driver certified to UL and CUL standards r Standard 0-10V continuous dimming driver r L70 at 50,000 hours with 5 year warranty 5-1/16" [129mm] Compliances may not apply to all product configurations. Please consult the product spec sheet for compliance details. COMPLIANCES: UL/cUL Listed 4" [102mm] 23DR LED STRAIGHT AND NARROW ORDERING INFORMATION SAMPLE NUMBER: S23DR-1L35-ETG-xx-U-DD-S92HT Series Light Distribution Mounting Light Level Lamp Type Ceiling Type Length S23=Series 23 D=Direct R=Recessed LED ((3500K)) 4ft 1=Light Level 1, 2100 Lumens, 33 Watts 2=Light Level 2, 2700 Lumens, 44 Watts LED (3500K) ( ) L30=LED, 3000K 1 L35=LED, 3500K L40=LED, 4000K 2 ETG=15/16" Exposed T-Grid FTG=9/16" Exposed T-Grid STG=Slot T-Grid SR=Sheet Rock (Flanged) FSR=Sheet Rock (Trimless) xx=Continuous Run 2=2' 3=3' 4=4' 6=6' 8=8' Voltage Driver Shielding Options 120=120V 277=277V UNV=Universal (120V-277V) ED=Electronic Driver DD=Dimming Driver S92HT=Lay-in High Transmission Lens S92HTS=Snap in High Transmission Lens NEO-RAY NOTES: 1. Subtract 10% from 3500K light levels. 2. Add 10% to 3500K light levels. Specifications and dimensions subject to change without notice. Consult your Cooper Lighting Representative or visit www.cooperlighting.com for available options, accessories and ordering information. 9-103 Cooper Lighting by Eaton | Product Selection Guide | Sixth Edition | www.cooperlighting.com 5-1/16" [129mm] NEW PRODUCTS DIRECT FEATURES rExtruded aluminum housing in 2', 3', 4', 6' or 8' illuminated sections rHigh transmisson and opal lens options in lay in and snap in shapes r Durable, low-gloss, white, powder-coated acrylic finish rIndividual fixtures or run configurations rTwo LED light levels r Available in three CCT options: 3000K, 3500K and 4000K r120-277 voltage electronic driver certified to UL and CUL standards rStandard 0-10V continuous dimming driver r L70 at 50,000 hours with 5 year warranty Compliances may not apply to all product configurations. Please consult the product spec sheet for compliance details. COMPLIANCES: UL/cUL Listed 4" [102mm] 23DP LED STRAIGHT AND NARROW ORDERING INFORMATION SAMPLE NUMBER: S23DP-1L35-SCETG-4-U-DD-S92HT Series Light Distribution Mounting Light Level Lamp Type Mounting Type Length S23=Series 23 D=Direct P=Pendant LED ((3500K)) 4ft 1=Light Level 1, 2100 Lumens, 33 Watts 2=Light Level 2, 2700 Lumens, 44 Watts LED (3500K) ( ) L30=LED, 3000K 1 L35=LED, 3500K L40=LED, 4000K 2 SC=Single Cable SCETG=SC on ETG SCSTG=SC on STG SCFTG=SC on FTG SCSR=SC on SR xx=Continuous Run 2=2' 3=3' 4=4' 6=6' 8=8' Voltage Driver Shielding Options 120=120V 277=277V UNV=Universal (120V-277V) ED=Electronic Driver DD=Dimming Driver S92HT=Lay-in High Transmission Lens S92HTS=Snap in High Transmission Lens NOTES: 1. Subtract 10% from 3500K light levels. 2. Add 10% to 3500K light levels. NEO-RAY Specifications and dimensions subject to change without notice. Consult your Cooper Lighting Representative or visit www.cooperlighting.com for available options, accessories and ordering information. Cooper Lighting by Eaton | Product Selection Guide | Sixth Edition | www.cooperlighting.com 9-104 NEW PRODUCTS DIRECT FEATURES r Extruded aluminum housing in 2', 3', 4', 6' or 8' illuminated sections r High transmisson and opal lens options in lay in and snap in shapes r Durable, low-gloss, white, powder-coated acrylic finish r Individual fixtures or run configurations r Two LED light levels r Available in three CCT options: 3000K, 3500K and 4000K r 120-277 voltage electronic driver certified to UL and CUL standards r Standard 0-10V continuous dimming driver r L70 at 50,000 hours with 5 year warranty 5-1/16" [129mm] Compliances may not apply to all product configurations. Please consult the product spec sheet for compliance details. COMPLIANCES: UL/cUL Listed 23DS LED STRAIGHT AND NARROW 4" [102mm] ORDERING INFORMATION SAMPLE NUMBER: S23DS-1L35-ETG-4-U-DD-S92HT Series Light Distribution Mounting Light Level Lamp Type Ceiling Type Length S23=Series 23 D=Direct S=Surface LED ((3500K)) 4ft 1=Light Level 1, 2100 Lumens, 33 Watts 2=Light Level 2, 2700 Lumens, 44 Watts LED (3500K) ( ) L30=LED, 3000K 1 L35=LED, 3500K L40=LED, 4000K 2 ETG=15/16" Exposed T-Grid FTG=9/16" Exposed T-Grid STG=Slot T-Grid SR=Sheet Rock (Flanged) xx=Continuous Run 2=2' 3=3' 4=4' 6=6' 8=8' Voltage Driver Shielding Options 120=120V 277=277V UNV=Universal (120V-277V) ED=Electronic Driver DD=Dimming Driver S92HT=Lay-in High Transmission Lens S92HTS=Snap in High Transmission Lens NEO-RAY NOTES: 1. Subtract 10% from 3500K light levels. 2. Add 10% to 3500K light levels. Specifications and dimensions subject to change without notice. Consult your Cooper Lighting Representative or visit www.cooperlighting.com for available options, accessories and ordering information. 9-105 Cooper Lighting by Eaton | Product Selection Guide | Sixth Edition | www.cooperlighting.com 4-1/2" [114mm] 5-1/16" [129mm] NEW PRODUCTS DIRECT FEATURES r Extruded aluminum housing in 2', 3', 4', 6' or 8' illuminated sections r High transmisson and opal lens options in lay in and snap in shapes rDurable, low-gloss, white, powder-coated acrylic finish r Individual fixtures or run configurations r Two LED light levels rAvailable in three CCT options: 3000K, 3500K and 4000K r 120-277 voltage electronic driver certified to UL and CUL standards r Standard 0-10V continuous dimming driver rL70 at 50,000 hours with 5 year warranty Compliances may not apply to all product configurations. Please consult the product spec sheet for compliance details. COMPLIANCES: UL/cUL Listed 4" [102mm] 23DW LED STRAIGHT AND NARROW ORDERING INFORMATION SAMPLE NUMBER: S23DW-1L35-4-U-DD-S92HT Series Light Distribution Mounting Light Level Lamp Type Length S23=Series 23 D=Direct W=Wall LED ((3500K)) 4ft 1=Light Level 1, 2100 Lumens, 33 Watts 2=Light Level 2, 2700 Lumens, 44 Watts LED (3500K) ( ) L30=LED, 3000K 1 L35=LED, 3500K L40=LED, 4000K 2 xx=Continuous Run 2=2' 3=3' 4=4' 6=6' 8=8' Voltage Driver Shielding Options 120=120V 277=277V UNV=Universal (120V-277V) ED=Electronic Driver DD=Dimming Driver S92HT=Lay-in High Transmission Lens S92HTS=Snap in High Transmission Lens NOTES: 1. Subtract 10% from 3500K light levels. 2. Add 10% to 3500K light levels. NEO-RAY Specifications and dimensions subject to change without notice. Consult your Cooper Lighting Representative or visit www.cooperlighting.com for available options, accessories and ordering information. Cooper Lighting by Eaton | Product Selection Guide | Sixth Edition | www.cooperlighting.com 9-106 NEW PRODUCTS DIRECT-INDIRECT FEATURES r Extruded aluminum housing in 2', 3', 4', 6' or 8' illuminated sections r High transmisson and opal lens options in lay in and snap in shapes r Durable, low-gloss, white, powder-coated acrylic finish r Individual fixtures or run configurations r Two LED light levels r Available in three CCT options: 3000K, 3500K and 4000K r 120-277 voltage electronic driver certified to UL and CUL standards r Standard 0-10V continuous dimming driver r L70 at 50,000 hours with 5 year warranty 5-5/8" [143mm] Compliances may not apply to all product configurations. Please consult the product spec sheet for compliance details. COMPLIANCES: UL/cUL Listed 22DIP LED STRAIGHT AND NARROW 2-3/8" [60mm] ORDERING INFORMATION SAMPLE NUMBER: S22DIP-1L35-SCETG-4-U-DD-S92HT Series Light Distribution Mounting Light Level Lamp Type Mounting Type Length Voltage S22=Series 22 DI=Direct/Indirect P=Pendant LED ((3500K)) 4ft 1=Light Level 1, 1700 Lumens UP/1700 Lumens Down, 56.6 Watts 2=Light Level 2, 2200 Lumens UP/2200 Lumens Down, 74.6 Watts LED (3500K) ( ) L30=LED, 3000K 1 L35=LED, 3500K L40=LED, 4000K 2 SC=Single Cable SCETG=SC on ETG SCSTG=SC on STG SCFTG=SC on FTG SCSR=SC on SR 2=2' 3=3' 4=4' 6=6' 8=8' _=Continuous Run 3 120=120V 277=277V UNV=Universal (120V-277V) Driver Circuiting Shielding Options ED=Electronic Driver DD=Dimming Driver SI=Single Circuit DU=Dual Circuit S92HT=Lay-in High Transmission Lens S92HTS=Snap in High Transmission Lens NOTES: 1. Subtract 10% from 3500K light levels. 2. Add 10% to 3500K light levels. 3. Continuous runs to the nearest foot. Contact factory for specific dimensions. DIRECT-INDIRECT FEATURES r Extruded aluminum housing in 2', 3', 4', 6' or 8' illuminated sections r High transmisson and opal lens options in lay in and snap in shapes r Durable, low-gloss, white, powder-coated acrylic finish r Individual fixtures or run configurations r Two LED light levels r Available in three CCT options: 3000K, 3500K and 4000K r 120-277 voltage electronic driver certified to UL and CUL standards r Standard 0-10V continuous dimming driver r L70 at 50,000 hours with 5 year warranty 5-5/8" [143mm] Compliances may not apply to all product configurations. Please consult the product spec sheet for compliance details. COMPLIANCES: UL/cUL Listed 23DIP LED STRAIGHT AND NARROW 4" [102mm] ORDERING INFORMATION NEO-RAY SAMPLE NUMBER: S23DIP-1L35-4-U-DD-S92HT Series Light Distribution Mounting Light Level Lamp Type Mounting Type Length S23=Series 23 DI=Direct/Indirect P=Pendant LED ((3500K)) 4ft 1=Light Level 1, 1700 Lumens UP/1700 Lumens Down, 56.6 Watts 2=Light Level 2, 2200 Lumens UP/2200 Lumens Down, 74.6 Watts LED (3500K) ( ) L30=LED, 3000K 1 L35=LED, 3500K L40=LED, 4000K 2 SC=Single Cable SCETG=SC on ETG SCSTG=SC on STG SCFTG=SC on FTG SCSR=SC on SR xx=Continuous Run 2=2' 3=3' 4=4' 6=6' 8=8' Voltage Driver Circuiting Shielding Options 120=120V 277=277V UNV=Universal (120V-277V) ED=Electronic Driver DD=Dimming Driver SI=Single Circuit DU=Dual Circuit S92HT=Lay-in High Transmission Lens S92HTS=Snap in High Transmission Lens NOTES: 1. Subtract 10% from 3500K light levels. 2. Add 10% to 3500K light levels. Specifications and dimensions subject to change without notice. Consult your Cooper Lighting Representative or visit www.cooperlighting.com for available options, accessories and ordering information. 9-107 Cooper Lighting by Eaton | Product Selection Guide | Sixth Edition | www.cooperlighting.com 3" [76mm] 5-5/8" [143mm] NEW PRODUCTS DIRECT-INDIRECT FEATURES rExtruded aluminum housing in 2', 3', 4', 6' or 8' illuminated sections rHigh transmisson and opal lens options in lay in and snap in shapes r Durable, low-gloss, white, powder-coated acrylic finish rIndividual fixtures or run configurations rTwo LED light levels r Available in three CCT options: 3000K, 3500K and 4000K r120-277 voltage electronic driver certified to UL and CUL standards rStandard 0-10V continuous dimming driver r L70 at 50,000 hours with 5 year warranty Compliances may not apply to all product configurations. Please consult the product spec sheet for compliance details. COMPLIANCES: UL/cUL Listed, ADA Compliant 22DIW LED STRAIGHT AND NARROW 2-3/8" [60mm] ORDERING INFORMATION SAMPLE NUMBER: S22DIW-1L35-SCETG-4-U-DD-S92HT Series Light Distribution Mounting Light Level Lamp Type Length Voltage Driver S22=Series 22 DI=Direct/Indirect W=Wall LED ((3500K)) 4ft 1=Light Level 1, 1700 Lumens UP/1700 Lumens Down, 56.6 Watts 2=Light Level 2, 2200 Lumens UP/2200 Lumens Down, 74.6 Watts LED (3500K) ( ) L30=LED, 3000K 1 L35=LED, 3500K L40=LED, 4000K 2 2=2' 3=3' 4=4' 6=6' 8=8' _=Continuous Run 3 120=120V 277=277V UNV=Universal (120V-277V) ED=Electronic Driver DD=Dimming Driver Circuiting Shielding Options SI=Single Circuit DU=Dual Circuit S92HT=Lay-in High Transmission Lens S92HTS=Snap in High Transmission Lens NOTES: 1. Subtract 10% from 3500K light levels. 2. Add 10% to 3500K light levels. 3. Continuous runs to the nearest foot. Contact factory for specific dimensions. DIRECT-INDIRECT FEATURES r Extruded aluminum housing in 2', 3', 4', 6' or 8' illuminated sections r High transmisson and opal lens options in lay in and snap in shapes rDurable, low-gloss, white, powder-coated acrylic finish r Individual fixtures or run configurations r Two LED light levels rAvailable in three CCT options: 3000K, 3500K and 4000K r 120-277 voltage electronic driver certified to UL and CUL standards r Standard 0-10V continuous dimming driver rL70 at 50,000 hours with 5 year warranty 4-1/2" [114mm] 5-1/16" [129mm] Compliances may not apply to all product configurations. Please consult the product spec sheet for compliance details. COMPLIANCES: UL/cUL Listed 23DIW LED STRAIGHT AND NARROW 4" [102mm] ORDERING INFORMATION SAMPLE NUMBER: S23DIW-1L35-xx-UNV-DD-SI-S92HT Series Light Distribution Mounting Light Level Lamp Type Length Voltage S23=Series 23 DI=Direct/Indirect W=Wall LED ((3500K)) 4ft 1=Light Level 1, 1700 Lumens UP/1700 Lumens Down, 56.6 Watts 2=Light Level 2, 2200 Lumens UP/2200 Lumens Down, 74.6 Watts LED (3500K) ( ) L30=LED, 1 3000K L35=LED, 3500K L40=LED, 4000K 2 2=2' 3=3' 4=4' 6=6' 8=8' xx=Continuous Run 120=120V 277=277V UNV=Universal (120V-277V) Circuiting Shielding Options ED=Electronic Driver DD=Dimming Driver SI=Single Circuit DU=Dual Circuit S92HT=Lay-in High Transmission Lens S92HTS=Snap in High Transmission Lens NOTES: 1. Subtract 10% from 3500K light levels. NEO-RAY Driver 2. Add 10% to 3500K light levels. Specifications and dimensions subject to change without notice. Consult your Cooper Lighting Representative or visit www.cooperlighting.com for available options, accessories and ordering information. Cooper Lighting by Eaton | Product Selection Guide | Sixth Edition | www.cooperlighting.com 9-108 NEW PRODUCTS INDIRECT Wall blocking (by others) FEATURES r Extruded aluminum housing in 2', 3', 4', 6' or 8' illuminated sections r High transmisson and opal lens options in lay in and snap in shapes r Durable, low-gloss, white, powder-coated acrylic finish r Individual fixtures or run configurations r Two LED light levels r Available in three CCT options: 3000K, 3500K and 4000K r 120-277 voltage electronic driver certified to UL and CUL standards r Standard 0-10V continuous dimming driver r L70 at 50,000 hours with 5 year warranty 1/8" [4mm] 3-1/16" [78mm] 4-1/16" [104mm] Compliances may not apply to all product configurations. Please consult the product spec sheet for compliance details. COMPLIANCES: UL/cUL Listed 22IW LED STRAIGHT AND NARROW 2-3/8" [61mm] 1/2" [13mm] ORDERING INFORMATION SAMPLE NUMBER: S22IW-1L35-ETG-4-U-DD-S92HT Series Light Distribution Mounting Light Level Lamp Type Length Voltage Driver S22=Series 22 I=Indirect W=Wall LED ((3500K)) 4ft 1=Light Level 1, 1757 Lumens, 28.4 Watts (439 Lumens; 7.1 Watts Per Foot) 2=Light Level 2, 2253 Lumens, 37.5 Watts (653 Lumens; 9.3 Watts Per Foot) LED (3500K) ( ) L30=LED, 3000K 1 L35=LED, 3500K L40=LED, 4000K 2 2=2' 3=3' 4=4' 6=6' 8=8' 1=120V 2=277V U=Universal (120-277V) ED=Electronic Driver DD=Dimming Driver Driver Options Emergency Shielding Options Blank=Standard 0-10V Dimming Driver 5LT=Fifthlight DALI Driver LUT=Lutron DALI Driver EM=Emergency Pack 3 EC=Emergency Circuit S92=Lay-in Satin White Lens S92HT=Lay-in High Transmission Lens S92HTS=Snap in High Transmission Lens S92S=Snap-in Satin White Lens NOTES: 1. Subtract 10% from 3500K light levels. 2. Add 10% to 3500K light levels. 3. Remote mount only. INDIRECT FEATURES r Extruded aluminum housing in 2', 3', 4', 6' or 8' illuminated sections r High transmisson and opal lens options in lay in and snap in shapes r Durable, low-gloss, white, powder-coated acrylic finish r Individual fixtures or run configurations r Two LED light levels r Available in three CCT options: 3000K, 3500K and 4000K r 120-277 voltage electronic driver certified to UL and CUL standards r Standard 0-10V continuous dimming driver r L70 at 50,000 hours with 5 year warranty 4-1/2" [114mm] 5-1/16" [129mm] Compliances may not apply to all product configurations. Please consult the product spec sheet for compliance details. COMPLIANCES: UL/cUL Listed 23IW LED STRAIGHT AND NARROW 4" [102mm] ORDERING INFORMATION NEO-RAY SAMPLE NUMBER: S23IW-1L35-4-UNV-DD-S92HT Series Light Distribution Mounting Light Level Lamp Type Length Voltage S23=Series 23 I=Indirect W=Wall LED ((3500K)) 4ft 1=Light Level 1, 2100 Lumens, 33 Watts 2=Light Level 2, 2700 Lumens, 44 Watts LED (3500K) ( ) L30=LED, 3000K 1 L35=LED, 3500K L40=LED, 4000K 2 xx=Continuous Run 2=2' 3=3' 4=4' 5=5' 6=6' 8=8' 120=120V 277=277V UNV=Universal (120V-277V) Driver Shielding Options ED=Electronic Driver DD=Dimming Driver S92HT=Lay-in High Transmission Lens S92HTS=Snap in High Transmission Lens NOTES: 1. Subtract 10% from 3500K light levels. 2. Add 10% to 3500K light levels. Specifications and dimensions subject to change without notice. Consult your Cooper Lighting Representative or visit www.cooperlighting.com for available options, accessories and ordering information. 9-109 Cooper Lighting by Eaton | Product Selection Guide | Sixth Edition | www.cooperlighting.com Bur naby 39352ndAvenue Bur naby ,BCV5C3W9 T el :6042924800 Cr anbr ook Uni tA#800I ndus t r i alRoad.#2 Cr anbr ook,BCV1C4C9 T el :2504894591 Daws onCr eek 110197t hAvenue Daws onCr eek,BCV1G1N5 T el :2507824896 Langl ey #101-20550DuncanWay Langl ey ,BCV3A7A3 T el :6045331275 Kaml oops B983Camos unCr es cent Kaml oops ,BCV2C6G1 T el :2503743191 For tNel s on POBox3266-501648t hAvenue For tNel s on,BCV0C1R0 T el :2502338570 Ri chmond 12360Vi cker sWay Ri chmond,BCV6V1H9 T el :6042731981 Pent i ct on 401OkanaganAvenue Pent i ct on,BCV2A3K1 T el :2504924032 Ki t i mat 622Commer ci alAvenue Ki t i mat ,BCV8C2C5 T el :2506323774 Sur r ey 1305580t hAvenue Sur r ey ,BCV3W 3B1 T el :6045967111 Ver non 520324t hSt r eet Ver non,BCV1T8X7 T el :2505452191 Pr i nceGeor ge 2255S.Qui nnSt r eet Pr i nceGeor ge,BCV2N2X4 T el :2505630575 Wi l l i amsLake 527S.MacKenz i eAvenue Wi l l i amsLake,BCV2G1C8 T el :2503927795 T er r ace 5000Pohl eAvenue T er r ace,BCV8G4S8 T el :2506356379 Campbel lRi ver 1030B-9t hAvenue Campbel lRi ver ,BCV9W 4C2 T el :2502879265 Cour t enay 2615Mor ayPl ace Cour t enay ,BCV9N8A9 T el :2503340338 Duncan 5286Pol keyRoad Duncan,BCV9L6W3 T el :2507483377 Uni t9,722368Avenue, Edmont on,Al ber t a T6B3T6 Pr oces s ,Aut omat i on& Cont r ol sGr oup T el :7785459916 Pr oj ect sGr oup T el :6045967111 Dat aCommuni cat i onsGr oup T el :7785459916 Li ght i ngSpeci al i s t T el :7785459916 Par ks vi l l e #105-425E.St anf or dAvenue Par ks vi l l e,BCV9P2N4 T el :2509541797 HeadOf f i ce 1929525t hAvenue Sur r ey ,BCV3Z3X1 T el :7785459916 Fax:7785453099 T ol lFr ee:18884677626