Wall-Mounted Area Lighter, Polycarbonate Refractor Wall-Paks Use in entrances, loading docks, walkways and vehicle ramps. TWP Catalog Number Example: TWP 175M TB I Designation Voltage HIGH PRESSURE SODIUM 35W TWP 35S ''2 50W TWP 50S' 70W TWP 70S 100W TWP 100S 150W TWP 1 5 0 S 3 4 120 2086 2406 277 347 4806 TB 7 METAL HALIDE 70W TWP 70M 100W TWP 100M4 150W TWP 150M 5 175W TWP 175M Options/Accessories SCWA SuperCWA pulse start ballast (TB std.) LLRPSL Low loss reactor pulse start ballast (277V only) For options and accessories, see page 312. NOTES: 1 NotavailablewithTB. 2 120Vonly. 3 Operates55Vlamp. 4 Notavailable480V. 5 May be ordered with SCWA or LLRPSL. 6 NotavailableinCanada. 7 Optional Multi-tap Ballast (120,208,240, 277V). (120,277,347V in Canada.) 8 Other ballasttypes available. MERCURY VAPOR 100W TWP 100H 175W TWP 1 7 5 H LOW PRESSURE SODIUM 35W TWP 35L' INCANDESCENT 200W TWP 200I CANADIAN SHIPMENTS: Add CSAas suffix to catalog number. HID lamps available with luminaires. Consult factory. Lamp/Fixture/Ballast Data8 Wattage Weight Ballast____Lbs. Kg.____ HIGH PRESSURE SODIUM (Med/Clear) 35 RHP 12 5 50 RHP 13 6 70 XHP 15 7 100 XHP 14 6 150 XHP 15 7 METAL HALIDE (Med(100)/Mog(175)/Clear) 70 HX-HPF 16 7 100 HX-HPF 16 7 175 CWA 16 7 MERCURY VAPOR (Mog/Coated) 100 CWA 11 5 175 CWA 21 10 LOW PRESSURE SODIUM (D.C. Bay/Clear) 35 HPF-LAG 14 6 Features Housing: Rear housing is rugged, corrosionresistant, die-cast aluminum. Corrosion-resistant, captive external hardware includes slotted hex-head and tamperproof fasteners. Optics: Reflector is aluminum, finished in white enamel. Front housing and refractor are one-piece, injection-molded, UVstabilized polycarbonate. Standard finish on opaque portion of front cover and back housing is dark bronze polyester enamel, electrostatically applied. Refractor is sealed and gasketed to inhibit the entrance of outside contaminants. Ballast: HPS: High-reactance, high-power factor (XHP). Encased-and-potted solidstate ignitors (HPS and 100MH). MH and MV: Constant-wattage autotransformer. Ballast is copper wound and 100% factory tested. UL listed. Electrical components mounted on back housing. STANDARD PACKAGING Fixtures ship complete in unit cartons only. Example: (Qty 131 TWP 175M TB (13 cartons of 1 fixture) Installation: Top %" threaded wiring access. Back access through removable W knockout. Feed-thru wiring can be achieved by using a condulet tee (not included). Mount on any flat, non-combustiible vertical surface. A c c e s s o r i e s ship separately. Socket: Glazed porcelain (mogul base), horizontally oriented socket with copper alloy, nickel-plated screw shell and center contact. Medium-base: UL listed 660W, 600V, 4KV pulse rated. Mogul-base: UL listed 1500W, 600V, 4KV pulse rated. All dimensions are inches (centimeters) unless otherwise specified. Listings: UL listed suitable for wet locations. IP64 rated in accordance with IEC standard 529. Listed and labeled to comply with Canadian Standards (see options). DIMENSIONS Height: Width: Depth: L/GHT/NG 15 7 /is(39.2) 16Ys(41) 7*119.7) PSG6 267 Outdoor Lighting Electrical Options C22 12-3 SEO cord (21 prewired)* C42 14-3 SEO cord (2 C prewired)* C62 16-3 SEO cord (21 prewired)* CV3P 3 ft. of 16-3 SEO cord pre-wired w/3 prong plug for use with prewired cages and cross-arms. Must use matching receptacle, provided by others. Not available with 1500W-120V. DF Double Fuse. Use with 208,240,480V. Not available for Multi-tap Ballast. Inline, time-delay type fusing isolates faulty luminaire from circuit fusing. EC Emergency Circuit. Lamp not included. FD Festoon Outlet. Duplex receptacle. Cast box. FG Festoon Outlet. Duplex ground fault receptacle. Cast box. KW1 KiloWatch 120V control relay. KW4 KiloWatch 277V control relay. LS Lamp Support. Mogul-base socket only. MR1 Outdoor non-encapsulated remote ballast. MR2 Outdoor pitch-encapsulated remote ballast. MRS Outdoor epoxy-encapsulated remote ballast. MR4 Indoor non-encapsulated remote ballast. MR5 Indoor pitch-encapsulated remote ballast. MR6 Indoor epoxy-encapsulated remote ballast. PE PE1 PE3 PE4 PE7 PER QRS QRSTD SC SF WL Photoelectric Cell. (Button-type) Not available for multi-tap ballast or 480V. NEMA Twist-Lock Photocontrol. 120, 208, 240V. Shipped separately. NEMA Twist-Lock Photocontrol. 347V. Shipped separately. NEMA Twist-Lock Photocontrol. 480V. Shipped separately. NEMA Twist-Lock Photocontrol. 277V. Shipped separately. NEMA Twist-Lock Photocontrol. Receptacle. Can be rotated 90° for positioning. Photocontrol not included. Shipped installed. Quartz Restrike System. Activates when power interruption causes HID lamps to drop out. Deactivates when fixture restrikes. QRS does not energize during cold start of fixture. Wattage of quartz lamp should not exceed that of HID source. For 100W and below, use 100W DC bayonet-base lamp. Quartz Restrike Time Delay. Functions as does QRS, but quartz lamp energizes under hot and cold starting conditions. Quartz lamp will come on when luminaire is energized and remain on for two minutes after restrike. Shorting Cap for PER. Ships as SC U. Single Fuse. Use with 120,277,347V. Not available for Mult-tap Ballast. Inline, time-delay type fusing isolates faulty luminaire from circuit fusing. Wet Location. Gasketed use with KP only. NOTES: * Other cord lengths available (consult factory). H AREA LIGHTING = AVAILABLE AS AN OPTION, SHIPPED INSTALLED Q = AVAILABLE AS AN ACCESSORY, SHIPPED SEPARATELY C22 C42 C62 CV3P DF EC FD • • m • • • • • • m • • • • BV KSE KSF KAD KAC KT KVE KVR KVS KAR KKS KKR KQS KQR FG KW1 KW4 LS MR1 MR2 MRS IVIR4 MR5 MR6 PE m a a a a a a a a a a a a a a a a a a a a a a a a a a m3 1 m a •' >L a5 2 PE1 PE3 PE4 PE7 PER QRS QRSTD SC SF WL a • • a a a a a a a a a a a a a a a a a a a a a a a a a a a a • • • • • • • • • • • • • • • • • • • a a a a a a a a a a a a a a • • • • • • • • • • • • • • • • • • • • • • FLOODLIGHTING C22 C42 C62 CV3P DF KFL TFA TFD TFG TFR TFL TFM 55 95 170S NOTES: 1 KFLSonly 2 KAR2only 3 KSE2only 312 • • • • • • EC FD FG KW1 KW4 •< • • • • • LS MR1 MR2MR3MR4MR5 MR6 PE a a a a a a • PE1 PE3 PE4 PE7 PER QRS QRSTD SC SF WL a a a a a a a a a a a a a a a a a a a a • • • • • •' • • • • • • a a a a a a • • • a a a a • • a a a a • • a a a a • • • • • • • • • • a • u • a • a a a a a 4 KSF2/3only 5 KVR/KVE/KVSsize3only 6 70M, 150M and 70S not available with 480V or DF PSG6 L/THON/A L/GHr/NG