Wall-Mounted Area Lighter, Polycarbonate Refractor

advertisement
Wall-Mounted Area Lighter, Polycarbonate Refractor
Wall-Paks
Use in entrances, loading docks, walkways and vehicle ramps.
TWP
Catalog Number
Example: TWP 175M TB
I
Designation
Voltage
HIGH PRESSURE SODIUM
35W TWP 35S ''2
50W TWP 50S'
70W TWP 70S
100W TWP 100S
150W TWP 1 5 0 S 3 4
120
2086
2406
277
347
4806
TB 7
METAL HALIDE
70W TWP 70M
100W TWP 100M4
150W TWP 150M 5
175W TWP 175M
Options/Accessories
SCWA SuperCWA pulse start
ballast (TB std.)
LLRPSL Low loss reactor pulse
start ballast (277V only)
For options and accessories,
see page 312.
NOTES:
1 NotavailablewithTB.
2 120Vonly.
3 Operates55Vlamp.
4 Notavailable480V.
5 May be ordered with SCWA or LLRPSL.
6 NotavailableinCanada.
7 Optional Multi-tap Ballast (120,208,240,
277V). (120,277,347V in Canada.)
8 Other ballasttypes available.
MERCURY VAPOR
100W TWP 100H
175W TWP 1 7 5 H
LOW PRESSURE SODIUM
35W TWP 35L'
INCANDESCENT
200W
TWP 200I
CANADIAN SHIPMENTS: Add CSAas suffix
to catalog number.
HID lamps available with luminaires. Consult factory.
Lamp/Fixture/Ballast Data8
Wattage
Weight
Ballast____Lbs.
Kg.____
HIGH PRESSURE SODIUM (Med/Clear)
35
RHP
12
5
50
RHP
13
6
70
XHP
15
7
100
XHP
14
6
150
XHP
15
7
METAL HALIDE (Med(100)/Mog(175)/Clear)
70
HX-HPF
16
7
100
HX-HPF
16
7
175
CWA
16
7
MERCURY VAPOR (Mog/Coated)
100
CWA
11
5
175
CWA
21
10
LOW PRESSURE SODIUM (D.C. Bay/Clear)
35
HPF-LAG
14
6
Features
Housing: Rear housing is rugged, corrosionresistant, die-cast aluminum. Corrosion-resistant, captive external hardware includes
slotted hex-head and tamperproof fasteners.
Optics: Reflector is aluminum, finished in
white enamel. Front housing and refractor
are one-piece, injection-molded, UVstabilized polycarbonate. Standard finish
on opaque portion of front cover and back
housing is dark bronze polyester enamel,
electrostatically applied. Refractor is
sealed and gasketed to inhibit the entrance of outside contaminants.
Ballast: HPS: High-reactance, high-power
factor (XHP). Encased-and-potted solidstate ignitors (HPS and 100MH). MH and
MV: Constant-wattage autotransformer.
Ballast is copper wound and 100% factory
tested. UL listed. Electrical components
mounted on back housing.
STANDARD PACKAGING
Fixtures ship complete in unit
cartons only. Example:
(Qty 131 TWP 175M TB
(13 cartons of 1 fixture)
Installation: Top %" threaded wiring access.
Back access through removable W
knockout. Feed-thru wiring can be
achieved by using a condulet tee (not included). Mount on any flat, non-combustiible vertical surface.
A c c e s s o r i e s ship separately.
Socket: Glazed porcelain (mogul base), horizontally oriented socket with copper alloy,
nickel-plated screw shell and center contact.
Medium-base: UL listed 660W, 600V, 4KV
pulse rated. Mogul-base: UL listed 1500W,
600V, 4KV pulse rated.
All dimensions are inches
(centimeters) unless otherwise specified.
Listings: UL listed suitable for wet locations. IP64 rated in accordance with IEC
standard 529. Listed and labeled to comply
with Canadian Standards (see options).
DIMENSIONS
Height:
Width:
Depth:
L/GHT/NG
15 7 /is(39.2)
16Ys(41)
7*119.7)
PSG6
267
Outdoor Lighting Electrical Options
C22 12-3 SEO cord (21 prewired)*
C42 14-3 SEO cord (2 C prewired)*
C62 16-3 SEO cord (21 prewired)*
CV3P 3 ft. of 16-3 SEO cord pre-wired w/3 prong plug for use with prewired
cages and cross-arms. Must use matching receptacle, provided by
others. Not available with 1500W-120V.
DF Double Fuse. Use with 208,240,480V. Not available for Multi-tap Ballast. Inline, time-delay type fusing isolates faulty luminaire from circuit fusing.
EC Emergency Circuit. Lamp not included.
FD Festoon Outlet. Duplex receptacle. Cast box.
FG Festoon Outlet. Duplex ground fault receptacle. Cast box.
KW1 KiloWatch 120V control relay.
KW4 KiloWatch 277V control relay.
LS Lamp Support. Mogul-base socket only.
MR1 Outdoor non-encapsulated remote ballast.
MR2 Outdoor pitch-encapsulated remote ballast.
MRS Outdoor epoxy-encapsulated remote ballast.
MR4 Indoor non-encapsulated remote ballast.
MR5 Indoor pitch-encapsulated remote ballast.
MR6 Indoor epoxy-encapsulated remote ballast.
PE
PE1
PE3
PE4
PE7
PER
QRS
QRSTD
SC
SF
WL
Photoelectric Cell. (Button-type) Not available for multi-tap ballast or
480V.
NEMA Twist-Lock Photocontrol. 120, 208, 240V. Shipped separately.
NEMA Twist-Lock Photocontrol. 347V. Shipped separately.
NEMA Twist-Lock Photocontrol. 480V. Shipped separately.
NEMA Twist-Lock Photocontrol. 277V. Shipped separately.
NEMA Twist-Lock Photocontrol. Receptacle. Can be rotated 90° for
positioning. Photocontrol not included. Shipped installed.
Quartz Restrike System. Activates when power interruption causes HID
lamps to drop out. Deactivates when fixture restrikes. QRS does not energize during cold start of fixture. Wattage of quartz lamp should not exceed
that of HID source. For 100W and below, use 100W DC bayonet-base lamp.
Quartz Restrike Time Delay. Functions as does QRS, but quartz lamp
energizes under hot and cold starting conditions. Quartz lamp will come
on when luminaire is energized and remain on for two minutes after
restrike.
Shorting Cap for PER. Ships as SC U.
Single Fuse. Use with 120,277,347V. Not available for Mult-tap Ballast. Inline, time-delay type fusing isolates faulty luminaire from circuit fusing.
Wet Location. Gasketed use with KP only.
NOTES:
* Other cord lengths available (consult factory).
H
AREA LIGHTING
= AVAILABLE AS AN OPTION, SHIPPED INSTALLED
Q = AVAILABLE AS AN ACCESSORY, SHIPPED SEPARATELY
C22 C42 C62 CV3P DF EC
FD
•
•
m
•
•
•
•
•
•
m
•
•
•
•
BV
KSE
KSF
KAD
KAC
KT
KVE
KVR
KVS
KAR
KKS
KKR
KQS
KQR
FG
KW1 KW4
LS MR1 MR2 MRS IVIR4 MR5 MR6 PE
m
a a
a a
a
a a
a a
a a
a a
a a
a a
a
a a
a a
a a
a a
m3
1
m
a
•'
>L
a5
2
PE1 PE3 PE4 PE7 PER QRS QRSTD SC SF WL
a
•
•
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
a
a
a
a
a
a
a
a
a
a
a
a
a
a
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
FLOODLIGHTING
C22 C42 C62 CV3P DF
KFL
TFA
TFD
TFG
TFR
TFL
TFM
55
95
170S
NOTES:
1 KFLSonly
2 KAR2only
3 KSE2only
312
•
•
•
•
•
•
EC
FD
FG
KW1 KW4
•<
•
•
•
•
•
LS MR1 MR2MR3MR4MR5
MR6 PE
a a a a a
a •
PE1 PE3 PE4 PE7 PER QRS QRSTD SC SF WL
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
•
•
•
•
•
•'
•
•
•
•
•
•
a a a
a a a
•
•
•
a a a a • •
a a a a • •
a a a a • •
•
•
•
•
•
•
•
•
a •
u •
a •
a
a
a
a
a
4 KSF2/3only
5 KVR/KVE/KVSsize3only
6 70M, 150M and 70S not available with 480V or DF
PSG6
L/THON/A L/GHr/NG
Download