Bulletin B1806 • RIBMNLB-6NO R1 OUT N/O R2 OUT N/O R3 OUT N/O R4 OUT N/O R5 OUT N/O R6 OUT N/O R7 POLE 1 R1 R2 R3 R4 R5 R6 Master Relay R7 CLOSED 1 2 R1 R1 COM OPEN CLOSED 3 4 R2 R2 COM R3 R3 COM Alarm Input 2 Alarm Input 3 OPEN • RIBMNLB-2NO 3A Total Sourced from 24 Vac/dc Input or Dry Contact (Jumper Selectable) Isolated Dry Contact Outputs, Each Rated 1.5A @ 24 Vac/dc Alarm Input Indicators • RIBMNLB-4NO R7 POLE 2 Legend for Jumper Selection Master Alarm Indicator 24V Power CLOSED 5 6 R4 R4 COM R5 R5 COM Alarm Input 4 Alarm Input 5 OPEN R6 R6 COM Dry = 24V = COM 24V 4A Max Alarm Input 1 Alarm Input 6 Alarm Input Bypass Switches OF ELECTRIC SHOCK - MORE THAN ONE DISCONNECT MAY BE REQUIRED TO DEENERGIZE THE DEVICE BEFORE SERVICING. CAUTION: RISK DE CHOQUE ÉLECTRIQUE - PLUS D´UN INTERRUPTEUR GÉNÉRAL PEUVENT ÊTRE NÉCESSAIRE POUR METTRE L’ÉQUIPEMENT HORS TENSION AVANT L’ENTRETIEN. MISE EN GARDE: RISQUE Bulletin B1806 • RIBMNLB-6NO R1 OUT N/O R2 OUT N/O R3 OUT N/O R4 OUT N/O R5 OUT N/O R6 OUT N/O R7 POLE 1 R1 R2 R3 R4 R5 R6 Master Relay R7 CLOSED 1 2 R1 R1 COM OPEN CLOSED 3 4 R2 R2 COM R3 R3 COM Alarm Input 2 Alarm Input 3 OPEN • RIBMNLB-2NO 3A Total Sourced from 24 Vac/dc Input or Dry Contact (Jumper Selectable) Isolated Dry Contact Outputs, Each Rated 1.5A @ 24 Vac/dc Alarm Input Indicators • RIBMNLB-4NO R7 POLE 2 R5 R5 COM Alarm Input 4 Alarm Input 5 OPEN Master Alarm Indicator 24V Power CLOSED 5 6 R4 R4 COM Legend for Jumper Selection R6 R6 COM Dry = 24V = COM 24V 4A Max Alarm Input 1 Alarm Input 6 Alarm Input Bypass Switches OF ELECTRIC SHOCK - MORE THAN ONE DISCONNECT MAY BE REQUIRED TO DEENERGIZE THE DEVICE BEFORE SERVICING. CAUTION: RISK DE CHOQUE ÉLECTRIQUE - PLUS D´UN INTERRUPTEUR GÉNÉRAL PEUVENT ÊTRE NÉCESSAIRE POUR METTRE L’ÉQUIPEMENT HORS TENSION AVANT L’ENTRETIEN. MISE EN GARDE: RISQUE INSTALLATION INSTRUCTIONS Open breaker Inputs: • Alarm Inputs: Connect 2, 4 or 6 Alarms to Input terminal pairs. • Power Input: Connect to terminals marked 24Vac/dc & COM. • If tying Inputs to Earth Ground, use the COM terminals Outputs: • Dry Contact Outputs: Connect 2, 4 or 6 dry contact outputs from terminals to DDC controller. • General Purpose: Either 24V or Dry Contact selectable by jumper positions (Master Relay Poles 1 and 2) Bypass DIP switches: • Closing any combination of DIP switches will allow corresponding Alarm Inputs to be ignored. Close Breaker. Green Power LED will be on. If no alarm conditions exist, the dry contact inputs will be closed, the corresponding Red LEDs will be off and the Master Relay will be on. If an alarm condition exists, the corresponding dry contact input will be open, the corresponding LED will be ON, the Master Relay will be off and the Red Master Alarm LED will be on (unless that Alarm Input was Bypassed). FOR SUPPLY CONNECTIONS USE #14AWG WIRES OR LARGER RATED FOR AT LEAST 75ºC (167ºF). USE COPPER CONDUCTORS ONLY. www.functionaldevices.com 393225B INSTALLATION INSTRUCTIONS Open breaker Inputs: • Alarm Inputs: Connect 2, 4 or 6 Alarms to Input terminal pairs. • Power Input: Connect to terminals marked 24Vac/dc & COM. • If tying Inputs to Earth Ground, use the COM terminals Outputs: • Dry Contact Outputs: Connect 2, 4 or 6 dry contact outputs from terminals to DDC controller. • General Purpose: Either 24V or Dry Contact selectable by jumper positions (Master Relay Poles 1 and 2) Bypass DIP switches: • Closing any combination of DIP switches will allow corresponding Alarm Inputs to be ignored. Close Breaker. Green Power LED will be on. If no alarm conditions exist, the dry contact inputs will be closed, the corresponding Red LEDs will be off and the Master Relay will be on. If an alarm condition exists, the corresponding dry contact input will be open, the corresponding LED will be ON, the Master Relay will be off and the Red Master Alarm LED will be on (unless that Alarm Input was Bypassed). FOR SUPPLY CONNECTIONS USE #14AWG WIRES OR LARGER RATED FOR AT LEAST 75ºC (167ºF). USE COPPER CONDUCTORS ONLY. www.functionaldevices.com 393225B