The following table represents average maintained luminance levels found in various school applications across the country. Values are based on typical industry practices and IESNA guidelines. Factors such as speed and accuracy, age and contrast may lower or increase the necessary luminance. Consult the IESNA Lighting Handbook for details. Application Foot-candles Lux 50 fc 500 lx Assembly 10 fc 100 lx Social Activities 5 fc 50 lx 30-50 fc 300-500 lx Grooming 30 fc 300 lx Lavatory 15 fc 150 lx Dining Area 30 fc 300 lx Kitchen 50 fc 500 lx Handwritten tasks 50 fc 500 lx Printed Tasks 50 fc 500 lx Chalk/white boards 50 fc 500 lx Keyboards 30 fc 300 lx Monitors 3 fc 30 lx Administrative Offices Most reading tasks Auditorium Reading Bathrooms Cafeterias Classroom Computer Lab Reading printed material 50 fc 500 lx 75 fc 750 lx General exercising and recreation 30 fc 300 lx Basketball – college and pro 100 fc 1000 lx Basketball – high school 75 fc 750 lx 30 fc 300 lx 15-30 fc 150-300 lx 30 fc 300 lx 50 fc 500 lx 10 fc 100 lx 30 fc 300 lx 50 fc 500 lx 50 fc 500 lx Stairwells 15 fc 150 lx Study Halls 50 fc 500 lx Drafting Room Exterior (see table below) Gymnasium Hallway Horizontal Vertical Library Stack lighting, audiovisual, cataloging and circulation desks Open study areas Locker Room Maintenance Room Maintenance & wiring areas, gauge reading Medical Offices Medical exam area Science Lab Sports (see tables below) Technology Labs Rough Bench or machine work 30 fc 300 lx Medium bench or machine work, rough grinding, medium buffing and polishing 50 fc 500 lx Woodworking--rough sawing and bench work 30 fc 300 lx Woodworking --fine bench and machine work, fine sanding and finishing 75 fc 750 lx 30 fc 300 lx 300 - 1,000 fc 3,000 - 10,000 lx Welding -- orientation Welding --precision manual arc-welding Exterior Lighting Footcandles Lux Active Entrances-pedestrian or vehicle 5 fc 50 lx Inactive Entrances - normally locked 3 fc 30 lx Vital locations or structures (security) 5 fc 50 lx Building surroundings 1 fc 10 lx High Activity 3.6 fc 36 lx Medium Activity 2.4 fc 24 lx Low Activity 0.8 fc 8 lx High Activity 2 fc 20 lx Medium Activity 1 fc 10 lx 0.5 fc 5 lx Building Exterior-Site areas adjacent to Parking Areas Roadways - Non-dedicated and Private Low Activity Signs Bright surroundings, light surfaces 30 fc 500 lx Bright surroundings, dark surfaces 50 fc 1000 lx Dark surroundings, light surfaces 10 fc 200 lx Dark surroundings, dark surfaces 30 fc 500 lx 10 fc 100 lx Bedford or buff limestone, smooth buff face brick, concrete, aluminum 15 fc 150 lx Smooth or medium gray brick, common tan or dark field gray brick 20 fc 200 lx 35 fc 350 lx Buildings (Suburban) Terra Cotta, light marble, plaster Brownstone, stained shingles, other dark surfaces Sports Lighting Class of Play and Facilities Class Facility College I II X X High Schools X Elementary Schools Class I - Facilities with spectator capacity over 5000 Class II - Facilities for spectators of 5000 or less Class III - No special provision for spectators Class IV - Social and recreational, i.e. noncompetitive III IV X X X Illuminance Criteria for Football & Soccer Class of Play Horizontal Footcandles (Lux) Vertical Footcandles (Lux) Uniformity (Max. to Min.) I 100 fc (1000 lx) 80 fc (800 lx) 1.5 II 50 fc (500 lx) 40 fc (400 lx) 2.0 III 30 fc (300 lx) 2.5 IV 20 fc (200 lx) 3.0 Illuminance Criteria for Tennis Class of Play Horizontal Footcandles (Lux) Average Uniformity (Maximum to Minimum) Minimum Within Lines Within PPA* I 125 fc (1250) 100 fc (1000) 1.2 1.5 II 60 fc (600 lx) 40 fc (400 lx) 1.5 1.7 III 40 fc (400 lx) 30 fc (300 lx ) 1.7 2.0 IV 30 fc (300 lx) 20 fc (200 lx) 2.0 2.5 * Within the principal playing area which is 48 x 96 for a single court (36 x 78). Illuminance Criteria for Baseball and Softball Fields Class of Play Horizontal Footcandles (Lux) Infield Outfield Vertical Footcandles (Lux) Infield Outfield Horizontal Uniformity (Max. to Min.) Infield Outfield Vertical Uniformity (Max. to Min.) Infield Outfield I 150 fc (1500lx) 100 fc (1000lx) 100 fc (1000lx) 70 fc (700lx) 1.5 1.5 1.5 2.0 II 100 fc (1000lx) 70 fc (700lx) 70 fc (700lx) 50 fc (500lx) 1.5 1.7 1.7 2.5 III 50 fc (500lx) 50 fc (500lx) 40 fc (400lx) 25 fc (250lx) 2.0 2.5 IV 30 fc (300lx) 20 fc (200lx) 25 fc (250lx) 15 fc (150lx) 3.0 3.5