Safety Notices Innovators in Protection Technology Instruction Manual for Switch Disconnectors Types S400- NN S630- NN Be sure to read these Instructions and other associated documents accompanying the product thoroughly to be familiarize yourself with the product handling, safety information, and all other precautions before mounting, using, servicing, or inspecting the product. In these Instructions, safety notices are divided into "Warning" and "Caution" according to the hazard level: Warning : A warning notice with this symbol indicates that neglecting the suggested procedure or practice could result in lethal or serious personal injury. Caution : A caution notice with this symbol indicates that neglecting the suggested procedure or practice could result in moderate or slight personal injury and/or property damage. Caution notices could result in serious results in some cases. Note that failing to observe Because safety notices contain important information, be sure to read and observe them. ■Mounting Precautions (For detailed mounting dimensions, refer to the TemBreak2 catalogue.) ■Maintenance Precautions Caution Caution ●Service and/or inspection of the product must be done by persons having expert knowledge. ●Before servicing or inspecting the product, open an upstream circuit breaker or the like to isolate all sources of power. Otherwise, electric shock may result.. ●Regularly check that the switch disconnector terminal screws are tightened to torque values shown within this manual, failure to do so may result in fire. ●Electrical work should only be undertaken by suitably qualified persons. ●Do not place the product in an area that is subject to high temperature, high humidity, excessive dusty air, corrosive gas, strong vibration and shock, or other unusual conditions. Mounting in such areas could cause a fire or malfunction. ●Be careful to prevent foreign objects (debris, concrete powder, iron powder, etc.) and rainwater from entering product. These materials inside the product could cause a fire or malfunction. ●Prior to commencing any work on the product, open an upstream circuit breaker or isolator to ensure that no voltage is applied to the product. Otherwise, electrical shock may result. ●When connecting cable or busbar to the product, tighten terminal screws to the torque specified in this manual. Otherwise, a fire could result. ■Other Precautions ・ Do not carry this product by accessory leads, as this may cause damage to the product. ・ Unauthorised opening of the switch disconnector cover will invalidate product warranty. ・ When installing the product, use wires or conductors, the cross sectional areas of which accommodate the rated current of the product. Using wires or conductors with inadequate cross sectional areas may cause false tripping and overheat. ■Handling Precautions Warning This product is the Switch Disconnector. This is not a molded case circuit breaker. This product does not provide protection against short circuit and overcurrent. ●Never touch terminals. Otherwise, electric shock may result. Please retain this manual for future reference. The Manufacturer assumes no responsibility for damages resulting from non-application or incorrect application of the instructions provided herein. 7-2-10 Kamihigashi, Hiranoku, Osaka 547-0002, Japan TEL: 81-6-6791-9323/ FAX: 81-6-6791-9274 URL: www.terasaki.co.jp E-mail:int-sales@terasaki.co.jp 2G0433SAC( KRB-0413c) Packaged Items/Assembly Tools Operating Instructions Instr uctio n Switch Disconnector:1 Fitting Internal Accessories Instruction Manual:1 (This document) Auxiliary Switch M Type B Type Interpole Barrier (Only FC) TRIPPED T2AX00M * M type * T2AX00B Ring Mark Alarm Switch M Type B Type 3P: 2 4P: 3 T2AL00M * Auxiliary Switch a contact Handle Shunt Trip * T2SH00 Type 400AF S Front Connected (FC) Rear Connected (RC) Plug-in Connected (PM) Flush Plate Where Applicable (F.P) 3P 4P 3P 4P 3P 4P 3P 4P 3P 4P 3P 4P 3P 4P 6 8 4 4 6 8 4 4 4 4 6 8 4 4 S400-NN ( ON) * T2UV00 10mm S630-NN Trip Button M10×25 M10×30 M6×100 M6×100 M12×35 M12×30 M6×100 M6×100 M6×120 M6×120 M12×35 M12×30 M6×25 M6×25 ( OFF) Combination (ON) (OFF) RESET (ON) Slits of pulling out leads (OFF) Operation 10 13 17 19 Removal Pull Out Leads on Load Side 5 6 8 ○( OFF) ⇒ |( ON) |( ON) ⇒ ○( OFF) TRIP⇒ ○( OFF) Operation effort 110N 115N 125N In case of fitting one (or two) auxiliary switch, fit in an order from a left sideslot. ・ After fitting, verify the function of the Accessory. AX AL SH UV V b contact a contact b contact 11/AXc-14/AXa 11/AXc-12/AXb 91/ALc 91/ALc 21/AXc-24/AXa 21/AXc-22/AXb 31/AXc-34/AXa 31/AXc-32/AXb 94/ALa 92/ALb Undervoltagie Trip *Symbols of Accessories ( OFF) M Type Qty 630AF S B Type Connections/Poles Alarm Switch * T2AL00B Shunt Trip power source Undervoltage Trip power source C1-C2 D1-D2 Breaker Mounting Procedure for FC / RC Breaker Mounting Procedure for F.P ( Where Applicable ) Conductor Connection Procedure for RC / F.P ( Where Applicable ) Solderless Terminals Mounting Procedure for FC O 6 Z φM N 10 19 P N Flat Bar Stud V T2RP40*S 5 Solderless Terminal T2FW40S* (400AF) (400AF) T2RP46*S W (630AF) *:3 or4(Poles) *:3 or4(Poles) A A 2G0433SAC( KRB-0413c) M6×100 6.0∼7.4N・m Flush Plate N T2FP40S* M *:3 or4(Poles) P M6×25 6.0∼7.4N・m Conductor Connection Procedure for FC O 8 400AF 630AF M10×20 M8×25 18.6∼29.4N・m 6 8.8∼14.7N・m 14mm 13mm M12×35 M12×30 40.2∼65.7N・m V W ≦25mm ≦240mm2 X Special Screw M8×25 Z 7∼9.5N・m 25N・m 13 X Conductor Connection Procedure for PM Plug-in Mounting Block Mounting Procedure for PM G J 8 φD φH K φS 19 U φS C F E B C D E F G H B 400AF 630AF ≦25mm ≦12.5mm 10.5mm ≦25mm ≦12mm ≦12mm ≦10mm 11mm 17 T J Flat Bar 8 T2FB40*B R Q Q (400AF) T2FB46*B (630AF) *:3 or4(Poles) J K Breaker Mounting Procedure for PM Interpole Barrier Mounting Procedure 400AF 630AF M10×30 M10×25 13.7∼22.5N・m M12×40 M12×35 40.2∼65.7N・m Terminal Cover Mounting Procedure L L M5×30 3.6∼4.4N・m Handle Holder / Lock Mounting Procedure Handle Holder/Lock (OFF) T2HL40 Interpole Barrier T2BA40*S *:3 or4(Poles) (ON) Y ・When removing, remove the items in reverse order of mounting. Terminal Cover Lock T2CF00L Y M6×120 6.0∼7.4N・m Connection Terminal Cover FC ( without Flat Bar ) T2CF40*SL FC ( with Flat Bar ) T2CF40*SW RC / PM T2CR40*S max×3(φ5∼8) *:3 or4(Poles) ・When removing, remove the items in reverse order of mounting. ・When removing, remove the items in reverse order of mounting. ・Handle holder/ lock can be fitted in any position of |(ON) and ○(OFF). ・When you use this item as the handle lock, please fit padlocks in the procedure of ③. ・When removing, remove the items in reverse order of mounting. Q R S T ≦30mm ≦20mm 11mm ≦20mm U M10 18.6∼29.4N・m