Project: Fixture Type: Location: Contact: RSS-P SERIES Round Straight Poles Specifications: Application: Images: Lighting installations for side and top mounting of luminaires with effective projected area (EPA) not exceeding maximum allowable loading of the specified pole in its installed geographic location. Bolt Square (Outer) Bolt Square (Inner) Handhole Bolt Circle (Outer) 0˚ Construction: 90˚ 270˚ Bolt Circle (Inner) • SHAFT: One-piece straight steel with round cross section, Minimum yield of 46,000 psi (ASTM-A500, Grade C); Longitudinal weld seam to appear flush in shaft wall; Steel base plate with axial bolt circle slots welded flush to pole shaft having minimum yield of 36,000 psi (ASTM A36) • BASE COVER: Two-piece square aluminum base cover included standard • POLE CAP: Pole shaft supplied with removable cover when applicable; Tenon and post-top configurations also available • HAND HOLE: Rectangular 3x5 steel hand hole frame (2.38” x 4.38” opening); Mounting provisions for grounding lug located behind gasketed cover • ANCHOR BOLTS: Four galvanized anchor bolts provided per pole with minimum yield of 55,000 psi (ASTM F1554). Galvanized hardware with two washers and two nuts per bolt for leveling 180˚ Overall Height 10' - 30' Finish: Straight3.0 Square • Durable thermoset polyester powder coat paint finish with nominal mil thickness and Tapered Poles • Powder paint prime applied over “white metal” steel substrate cleaned via mechanical Anchor Bolt shot blast method Location in • Decorative finish coat available in seven standard colors; Custom colors available; RA Relation number prefer able; Internal protective coating available to Shaft Round Straight and Tapered Poles (All excluding RTA Group 1 (RTA Group 1 & & RTS Group 2) RTS Group 2) Handhole Anchor Bolt 18" in Location Relation to Shaft Rotation Rotation Handhole POLE CAP TENON Handhole BASE DETAIL BASE COVER 1 Flat Washer Base Plate Bolt Projection1 Flat Washer Hex Nut 2 Engineering of footing by others 3Y Catalog number: RSS-P 20 40 A 2L S2 Series Height Shaft Thickness Mounting Drill Pattern RSS-P -Round Straight Steel Pole XX - Reference pg. 2 ordering matrix XX - Reference pg. 2 ordering matrix X - Reference pg. 2 ordering matrix 1 2 2L 3T 4 TN For more information visit our website: www.progresscommercial.com - Single arm mount - Two fixtures at 180º - Two fixtures at 90º - Three fixtures at 90º - Four fixtures at 90º - Tenon (3”OD) 2L 1 2L MOUNTING ORIENTATION 2 Anchor Bolt Hex Nut Grout with drain Optional Level Foundation 1 BZ 1 2 2L 2 1 2L 3T 3T 2L 2 3Y 3Y 23T 4 4 3T 3T 2L 3T 3Y Denotes handhole Denotes handle location 3Y4 4 Denotes handhole location Denotes handhole location 4 3Y UL Denotes handhole location Denotes handhole location Options Finish Denotes handhole location S2 - 2 Bolt 3.5º Pattern B3 - Pattern for PCPAS B4 - Pattern for PCPAL BZ - Bronze BL - Black GN - Green 4 GFI EHH C05 C07 C20 HSC LAB UL RBC - 20 Amp GFCI RCPT & Cover Extra Handhole 0.5” Coupling 0.7” Coupling 2” Coupling Internal Coating Less Anchor Bolts UL Certified Round Base Cover Progress Lighting • 701 Millennium Boulevard • Greenville, SC 29607 Project: Fixture Type: Location: Contact: RSSP SERIES Round Straight Poles Ordering Information: Height Feet Meters Nominal Shaft Dimensions Wall Thickness Bolt Circle (suggested) Bolt Circle (range) Bolt Square (range) Base Plate Square Base Plate Thickness Anchor bolt size Bolt Projection Pole weight RSS-P-10-40-A-XX-XX 10 3.0 4" round 0.125” 9” 7.5" - 10" 5.30" - 7.07" 9" 0.75 3/4" x 30" x 3" 3.5 52 RSS-P-12-40-A-XX-XX 12 3.7 4" round 0.125” 9” 7.5" - 10" 5.30" - 7.07" 9" 0.75 3/4" x 30" x 3" 3.5 62 RSS-P-14-40-A-XX-XX 14 4.3 4" round 0.125” 9” 7.5" - 10" 5.30" - 7.07" 9" 0.75 3/4" x 30" x 3" 3.5 72 RSS-P-16-40-A-XX-XX 16 4.9 4" round 0.125” 9” 7.5" - 10" 5.30" - 7.07" 9" 0.75 3/4" x 30" x 3" 3.5 83 RSS-P-18-40-A-XX-XX 18 5.5 4" round 0.125” 9” 7.5" - 10" 5.30" - 7.07" 9" 0.75 3/4" x 30" x 3" 3.5 93 RSS-P-20-40-A-XX-XX 20 6.1 4" round 0.125” 9” 7.5" - 10" 5.30" - 7.07" 9" 0.75 3/4" x 30" x 3" 3.5 103 RSS-P-10-40-B-XX-XX 10 3.0 4" round 0.188" 9" 7.5" - 10" 5.30" - 7.07" 9" 0.75 3/4" x 30" x 3" 3.5 77 RSS-P-12-40-B-XX-XX 12 3.7 4" round 0.188" 9" 7.5" - 10" 5.30" - 7.07" 9" 0.75 3/4" x 30" x 3" 3.5 92 RSS-P-14-40-B-XX-XX 14 4.3 4" round 0.188" 9" 7.5" - 10" 5.30" - 7.07" 9" 0.75 3/4" x 30" x 3" 3.5 107 RSS-P-16-40-B-XX-XX 16 4.9 4" round 0.188" 9" 7.5" - 10" 5.30" - 7.07" 9" 0.75 3/4" x 30" x 3" 3.5 122 RSS-P-18-40-B-XX-XX 18 5.5 4" round 0.188" 9" 7.5" - 10" 5.30" - 7.07" 9" 0.75 3/4" x 30" x 3" 3.5 138 RSS-P-20-40-B-XX-XX 20 6.1 4" round 0.188" 9" 7.5" - 10" 5.30" - 7.07" 9" 0.75 3/4" x 30" x 3" 3.5 153 RSS-P-10-45-A-XX-XX 10 3.0 4.5" round 0.125" 9" 7.5" - 10" 5.30" - 7.07" 9" 0.75 3/4" x 30" x 3" 3.5 58 RSS-P-12-45-A-XX-XX 12 3.7 4.5" round 0.125" 9" 7.5" - 10" 5.30" - 7.07" 9" 0.75 3/4" x 30" x 3" 3.5 70 RSS-P-14-45-A-XX-XX 14 4.3 4.5" round 0.125" 9" 7.5" - 10" 5.30" - 7.07" 9" 0.75 3/4" x 30" x 3" 3.5 82 RSS-P-16-45-A-XX-XX 16 4.9 4.5" round 0.125" 9" 7.5" - 10" 5.30" - 7.07" 9" 0.75 3/4" x 30" x 3" 3.5 93 RSS-P-18-45-A-XX-XX 18 5.5 4.5" round 0.125" 9" 7.5" - 10" 5.30" - 7.07" 9" 0.75 3/4" x 30" x 3" 3.5 105 RSS-P-20-45-A-XX-XX 20 6.1 4.5" round 0.125" 9" 7.5" - 10" 5.30" - 7.07" 9" 0.75 3/4" x 30" x 3" 3.5 117 RSS-P-25-45-A-XX-XX 25 7.6 4.5" round 0.125" 9" 7.5" - 10" 5.30" - 7.07" 9" 0.75 3/4" x 30" x 3" 3.5 146 RSS-P-10-50-B-XX-XX 10 3.0 5" round 0.188" 11" 8.0" - 11" 5.66" - 7.78" 10.25 1.0 3/4" x 30" x 3" 3.75 97 RSS-P-12-50-B-XX-XX 12 3.7 5" round 0.188" 11" 8.0" - 11" 5.66" - 7.78" 10.25 1.0 3/4" x 30" x 3" 3.75 116 RSS-P-14-50-B-XX-XX 14 4.3 5" round 0.188" 11" 8.0" - 11" 5.66" - 7.78" 10.25 1.0 3/4" x 30" x 3" 3.75 BASE135 COVER RSS-P-16-50-B-XX-XX 16 4.9 5" round 0.188" 11" 8.0" - 11" 5.66" - 7.78" 10.25 1.0 3/4" x 30" x 3" 3.75 155 RSS-P-18-50-B-XX-XX 18 5.5 5" round 0.188" 11" 8.0" - 11" 5.66" - 7.78" 10.25 1.0 3/4" x 30" x 3" 3.75 174 RSS-P-20-50-B-XX-XX 20 6.1 5" round 0.188" 11" 8.0" - 11" 5.66" - 7.78" 10.25 1.0 3/4" x 30" x 3" 3.75 193 RSS-P-25-50-B-XX-XX 25 7.6 5" round 0.188" 11" 8.0" - 11" 5.66" - 7.78" 10.25 1.0 3/4" x 30" x 3" 3.75 242 RSS-P-20-60-C-XX-XX 20 6.1 6" round 0.250" 11" 9.0" - 11" 6.36" - 7.78" 10.25 1.0 1" x 36" x 4" 4.5 307 RSS-P-25-60-C-XX-XX 25 7.6 6" round 0.250" 11" 9.0" - 11" 6.36" - 7.78" 10.25 1.0 1" x 36" x 4" 4.5 384 6" roundBolt Slots/Holes 0.250" 11" 9.0" - 11" 6.36" - 7.78" 10.25 1.0 4.5 461 Catalog Number Anchor Base Detail 180° Bolt Slots/Holes RSS-P-30-60-C-XX-XX 30 9.1 180° Bolt Circle 90° Arm 2 As viewed from top of pole. 270° Arm 1 Overall 1" x 36" xHeight 4" 10'-30' Bolt Circle 90° Arm 2 As viewed from top of pole. EHH C05 - C07 - C20 0°-Handhole Bolt Square EXTRA COUPLING Bolt Square HANDHOLE 270° Arm 1 GFI – 20 AMP GFCI RECEPTACLE & Round Steel Pole COVER 0°-Handhole BASE COVER Follow the logic below when ordering location specific options. For each18"option, include its orientation (in degrees) and its height (in feet). Example: Option C07 should be ordered as: SSS-H-20-40-A-TA-DB-CO7-0-15 (.5” coupling on the handhole/arm side of pole, 15 feet up from the pole base) 1’ spacing required between option. VIBRATION DAMPER Consult factory for other configurations. Overall Heighthand 10'-30' Standard hole frame 2” -11.5 NPSM Threads 3/4” - 14 NPSM Threads Adapter plate Gasket 20 AMP GFCI 2ND MODE Bolt Square (Outer) 18" Wet Locations In-use Cover Height of option in feet 0˚ Bolt Square (Inner) Handhole Bolt Circle (Outer) Bolt Square (Outer) 1/2” - 14 NPSM Threads 0˚ Bolt Square (Inner) 90˚ 270˚ Handhole Provision for Grounding Bolt Circle (Outer) Bolt Circle (Inner) 90˚ 270˚ 180˚ Bolt Circle (Inner) 180˚ For more information visit our website: www.progresscommercial.com OPTION ORIENTATION TENON TENON Progress Lighting • 701 Millennium Boulevard • Greenville, SC 29607 Project: Fixture Type: Location: Contact: ASCE7-05 Wind Map: Florida Region Wind Map: 130 120 140 85 115 115 150 90 100 110 120 130 120 130 130 90 90 Wind Map 150 140 140 150 United States and Canada 140 160 140 150 140 150 160 140 Special Wind Region (Consult Local Authorities) 90 140 100 130 110 120 170 170 150 NOTES: • The Wind Map is intended only as a general guide. Always • Values are based on 50 year mean recurrence interval 30’ consult local authorities to determine maximum wind above grade. velocities, gusting and unique wind conditions for each • Hawaii has an 105 mph wind velocity. specific application. • Puerto Rico has a 125 mph wind velocity. • CAUTION: Wind speeds and listed EPAs are for ground • Caution must be exercised in determining wind velocities mounted installations. Poles mounted on structures (such in special wind areas such as: as bridges and buildings) must consider vibration and Mountainous ASCE Regions 7-05 wind map EPA Load Rating - 3 second gust wind speeds coefficient of height factors beyond this general guide. Areas surrounding the Great Lakes or other large bodies Consult AASHTO standards. of water orNumber open land. Catalog 85 90 100 •Extreme 110 Wind 120 105 145 Cyclones, or Events: Hurricanes, Typhoons, Areas subject to extreme wind conditions, such as Tornadoes expose poles to flying debris, wind shear, and RSS-P-10-40-A 21.0and tornadoes. 18.7 15.0 12.2unpredictable 10.1 aerodynamic 13.5 forces 6.8not indicated by hurricanes, typhoons, cyclones, other the wind velocity ratings. Areas adjacent to airports. RSS-P-12-40-A 16.8 14.8 11.8 •Pole 9.5 Strength7.7 10.5 5.1 Limited Warranty: Standard, unmodified Kim Any specific area with a known or suspected abnormally lighting Poles installed as recommended, undamaged by high intermittent wind condition by geography, RSS-P-14-40-A 13.6caused12.0 9.4 7.4 5.9 8.3 3.9 corrosion, or lack of maintenance, shall withstand steady adjacent structures, or other specific local conditions wind conditions as provided on page 2 (Allowable Pole that may not be recorded in National Weather Service RSS-P-16-40-A 11.1 9.7 7.5 5.8 Installation 4.5 of poles6.6 2.9 EPA). without luminaires, or attachment records. of any unauthorized accessories to poles shall void this • Allowable pole EPA for jobsite 9.0 wind conditions RSS-P-18-40-A 7.8 must be5.8 4.4 3.3 5.1 2 warranty. equal to or greater than fixture EPA. Responsibility lies with the RSS-P-20-40-A specifier for correct pole selection on AASHTO 7.2 based6.2 4.5 3.1 2.2 3.8 1.2 wind map and job location. Hawaii - 105mph Peurto Rico - 145mph 180 Florida region wind map above is based upon 3-second gust winds and the 2010 Florida Building Code 180 Florida Building Code 2010 EPA Load Rating - 3 second gust wind speeds Catalog Number 115 120 130 140 150 160 170 180 RSS-P-10-40-A 25.0 23..5 20.0 17.0 14.5 12.5 11.0 10.0 RSS-P-12-40-A 21.0 19.0 16.0 13.5 11.5 9.5 9.0 8.0 RSS-P-14-40-A 17.5 15.7 13.0 10.8 9.0 7.5 7.0 6.5 RSS-P-16-40-A 14.2 13.0 10.5 8.5 7.0 5.8 5.0 4.5 RSS-P-18-40-A 11.6 10.4 8.2 6.8 5.4 4.4 4.0 3.6 RSS-P-20-40-A 9.5 8.4 6.5 5.2 4.0 3.0 2.8 2.5 RSS-P-10-40-B 25.0 25.0 22.4 18.4 15.3 20.2 10.4 RSS-P-10-40-B 25.0 25.0 25.0 22.0 19.0 16.5 15.2 13.4 RSS-P-12-40-B 25.0 22.3 17.9 14.5 12.0 16.1 8.1 RSS-P-12-40-B 25.0 25.0 20.8 17.6 15.1 13.0 12.0 10.6 RSS-P-14-40-B 20.6 18.3 14.6 11.7 9.6 13 6.4 RSS-P-14-40-B 22.5 20.4 17.2 14.4 12.2 10.4 10.0 8.8 RSS-P-16-40-B 17.2 15.2 12.0 9.5 7.7 10.7 5.1 RSS-P-16-40-B 18.9 17.0 14.1 11.7 9.8 8.2 7.5 7.0 RSS-P-18-40-B 14.3 12.6 9.8 7.6 6.1 8.6 3.9 RSS-P-18-40-B 15.6 14.1 11.5 9.4 7.7 6.4 6.0 5.7 RSS-P-20-40-B 11.8 10.3 7.9 6.0 4.7 6.9 2.9 RSS-P-20-40-B 13.0 11.6 9.3 7.5 6.0 4.8 4.0 3.5 RSS-P-10-45-A 25.0 24.3 19.5 16.0 13.5 17.6 9.1 RSS-P-10-45-A 25.0 25.0 25.0 22.0 19.9 17.2 15.0 13.4 RSS-P-12-45-A 21.8 19.4 15.4 12.6 10.6 13.9 7.1 RSS-P-12-45-A 25.0 24.7 20.5 17.5 16.0 13.9 12.0 10.6 RSS-P-14-45-A 17.9 15.8 12.4 10.1 8.4 11.1 5.6 RSS-P-14-45-A 22.0 20.0 16.8 14.2 13.3 11.4 10.0 8.7 RSS-P-16-45-A 14.8 13.0 10.1 8.1 6.7 8.9 4.4 RSS-P-16-45-A 18.6 16.8 13.8 11.5 11.0 9.3 8.0 7.0 RSS-P-18-45-A 12.1 10.6 8.0 6.3 5.2 7 3.3 RSS-P-18-45-A 15.4 13.8 11.2 9.1 8.3 7.6 6.5 5.6 RSS-P-20-45-A 9.9 8.5 6.3 4.9 3.9 5.4 2.4 RSS-P-20-45-A 12.7 11.3 9.0 7.2 6.8 6.2 5.2 4.4 RSS-P-25-45-A 5.7 4.7 3.0 2.0 1.5 2.4 NR RSS-P-25-45-A 7.6 6.5 4.9 3.5 3.3 3.1 2.8 2.2 RSS-P-10-50-B 25.0 25.0 25.0 25.0 25.0 25.0 17.7 RSS-P-10-50-B 25.0 25.0 25.0 25.0 25.0 23.6 20.8 18.4 RSS-P-12-50-B 25.0 25.0 25.0 24.8 20.8 25.0 14.3 RSS-P-12-50-B 25.0 25.0 25.0 25.0 22.2 19.3 16.8 14.8 RSS-P-14-50-B 25.0 25.0 24.7 20.5 17.2 22.4 11.7 RSS-P-14-50-B 25.0 25.0 23.9 21.5 18.4 15.9 13.8 12.1 RSS-P-16-50-B 25.0 25.0 20.7 17.1 14.3 18.8 9.7 RSS-P-16-50-B 25.0 23.8 19.6 18.0 15.4 13.2 11.4 9.9 RSS-P-18-50-B 24.5 21.6 17.3 14.3 11.9 15.7 8.0 RSS-P-18-50-B 21.8 19.6 16.1 15.1 12.8 10.8 9.3 8.0 RSS-P-20-50-B 20.6 18.1 14.4 11.8 9.8 13.0 6.5 RSS-P-20-50-B 18.2 16.4 14.1 12.7 10.7 9.0 7.7 6.5 RSS-P-25-50-B 13.6 11.7 9.1 7.3 6.0 8.1 3.8 RSS-P-25-50-B 11.7 10.2 9.4 8.4 6.8 5.6 4.5 3.7 RSS-P-20-60-C 25.0 25.0 25.0 25.0 21.5 25.0 14.8 RSS-P-20-60-C 25.0 25.0 25.0 22.1 18.8 16.1 13.9 12.0 RSS-P-25-60-C 25.0 25.0 21.9 18.0 15.0 19.8 10.1 RSS-P-25-60-C 24.7 22.4 18.4 15.3 12.8 10.8 9.1 7.6 RSS-P-30-60-C 21.8 19.4 15.6 12.7 10.6 14.1 6.9 RSS-P-30-60-C 18.2 16.3 13.2 10.7 8.7 7.0 5.7 4.5 NOTES • Allowable EPA, to determine max pole loading weight, multiply allowable EPA by 30 lbs. • The tables for allowable pole EPA are based on the ASCE 7-05 Wind Map or the Florida Region Wind Map for the 2010 Florida Building Code. The Wind Maps are intended only as a general guide an cannot be used in conjunction with other maps. Always consult local authorities to determine maximum wind velocities, gusting and unique wind conditions for each specific application • Allowable pole EPA for jobsite wind conditions must be equal to or greater than the total EPA for fixtures, arms, and accessories to be assembled to the pole. Responsibility lies with the specifier for cor rect pole selection. Installation of poles without luminaires or attachment of any unauthorized accessories to poles is discouraged and shall void the manufacturer’s warranty • Wind speeds and listed EPAs are for ground mounted installations. Poles mounted on structures (such as bridges and buildings) must consider vibration and coefficient of height factors beyond the general guide; Consult local and federal standards • Wind Induced Vibration brought on by steady, unidirectional winds and other unpredictable aerodynamic forces are not included in wind velocity ratings. Consult Hubbell Lighting’s Pole Vibration Application Guide for environmental risk factors and design considerations. • Extreme Wind Events like, Hurricanes, Typhoons, Cyclones, or Tornadoes may expose poles to flying debris, wind shear or other detrimental effects not included in wind velocity ratings For more information visit our website: www.progresscommercial.com Progress Lighting • 701 Millennium Boulevard • Greenville, SC 29607