Dimming & Switching Systems LCP128TM Spec Grade Power Equipment 369-642a 1 06.04.12 LCP128T Spec Grade Dimming System System Overview LCP128T is a combination dimming and switching system that provides a complete lighting control solution. The system consists of panels and control station devices. An integrated astronomical time clock provides system automation capability. System Features • 32 programmable lighting scenes and off. • Connect up to 8 power panels (spec grade and standard) for up to 128 dimmed/switched outputs. • Connect up to 32 wallstations or control devices for multiple points of control. • Entire system is programmed using the LCD controller mounted in the panel. • Astronomical time clock provides automated selection of lighting scenes. • Works directly with incandescent, magnetic lowvoltage, electronic low-voltage, neon, LutronR Tu-Wire® and switched load types. • Works with DSI, DALIR, and 0-10 V- dimming ballasts using 10 V modules in the panel. • Works with LutronR Eco-10® and Hi-Lume® Fluorescent Dimming Ballasts. • Feed-through or branch circuit breaker panels are available. • Panel is pre-wired and pre-tested. • Spec-grade panel may be surface mounted only. ® Job Name: Job Number: S p e c i f i c at i o n S u b m i t ta l Model Numbers: LCP128T Spec-Grade Panel Page 1 Dimming & Switching Systems LCP128TM Spec Grade Power Equipment 369-642a 2 06.04.12 LCP128T Controller Overview Lighting control may be automated by using the astronomical time clock integrated into the LCP128T controller. The controller has an LCD screen for easy programming. Features • LCD interface simplifies scene, time clock event, and control station programming. • Time clock events automatically recall presets at a specific time of day or at an offset from sunrise or sunset. • Up to 500 total events are programmable within 7 daily schedules and 40 holiday schedules. • Holiday schedules are programmable to run once or repeat up to 90 days in a row. • Two integrated contact closure inputs provide an interface with occupancy sensors or building management systems. • Select system location from a built-in city database or by entering latitude and longitude. • Time clock is battery backed; time and event settings are remembered even after power failures. • Programmable flash-warn feature. ® Job Name: Job Number: S p e c i f i c at i o n S u b m i t ta l Model Numbers: Page 2 Dimming & Switching Systems LCP128TM Spec Grade Power Equipment 369-642a 3 06.04.12 Specifications Standards • • • • ULR Listed (Reference: UL File E42071) CSA Certified California Energy Commission Listed Seismic Certified (Test Method AC156. Reference OSHPD Preapproval OSP-0215-10) • NOM certified models available. Power • Input power: 100-127 V and 277 V , 50/60 Hz, phase-to-neutral. • Branch Circuit Capacity: - 120-127 V : up to 2000 W/VA - 277 V : 4500 W/VA • Branch circuit breakers (if applicable): UL-rated thermal magnetic. AIC rating: - 100-127 V : 10,000 A - 277 V 14,000 A NOTE: See page 4 for SCCR ratings. • Lightning strike protection: meets ANSI/IEEE standard 62.41-1980. Can withstand surges of up to 6000 V and up to 3000 A. • 10-year power failure memory: automatically restores lighting to scene selected prior to power interruption. • RTISS filter circuit technology compensates for incoming line voltage variations: no visible flicker with +/-2% change in RMS voltage/cycle and +/-2% Hz change in frequency/second. Lighting Sources/Load Types • • • • • • • Operates these sources with a smooth continuous Square Law dimming curve or on a full conduction non-dim basis: Incandescent (tungsten)/halogen. Magnetic low-voltage transformer. LutronR Tu-Wire®. Neon. HID (full-conduction non-dim basis only). Switched lighting loads. DSI, DALI, and 0-10 V dimming ballasts using 10 V modules in the panel. ® Job Name: Job Number: S p e c i f i c at i o n S u b m i t ta l Model Numbers: • Electronic low-voltage transformer. • Magnetic fluorescent lamp ballasts • LutronR Hi-Lume® and Eco-10® fluorescent dimming ballasts are controlled directly Physical Design • Enclosure: NEMA-Type 1, IP-20 protection (Type 2 available upon request); 16 U.S. gauge steel. Indoors only. • Panel weight: - Spec-grade: 115 to 175 lb (52 to 79 kg) • Seismic Certification Limits: S = 2.5 g, z/h = 1.0, I = 1.5. Contact Lutron for details. DS P Mounting • Spec-grade panels surface mount only; allow space for ventilating. Environment • 32 to 104 °F (0 to 40 °C). • Relative humidity less than 90% non-condensing. Heat Dissipation • Panels cool by convection. No fans. Wiring • Internal: prewired by Lutron. • System communications: IEC PELV NECR Class 2 wiring connects dimming panels to other components. • Line (mains) voltage: feed and load wiring only. No other wiring or assembly required. LCP128T Controller • Configures entire LCP128T system. • Two low-voltage (15-24 V ) contact closure inputs, momentary or maintained, pull-up or pull-down. • Emergency sensing. • Astronomical time clock. • Digital control link. • Mounted inside LCP128T panel. Page 3 Dimming & Switching Systems LCP128TM Spec Grade Power Equipment 369-642a 4 06.04.12 Specifications (Continued) Dimming Cards Filter Chokes (spec-grade panel) • Load current rise time is measured at a 90 degree conduction angle. • 10 to 90% of load current waveform: - 350 µs rise time at 50% dimmer capacity. - 400 µs rise time at 100% dimmer capacity. • 0-100% of load current waveform: - 525 µs rise time at 50% dimmer capacity. - 600 µs rise time at 100% dimmer capacity. • At no point in the waveform can the rate of current change exceed 300 mA per µs. • Consult Lutron for higher rise time options. Astronomical Time Clock • Capable of up to 500 events. • 7 daily schedules and 40 holiday schedules are available. • 25 events per day. • Holiday events are programmable one year in advance. • Holiday schedules are programmable to run for up to 90 days. • ATC location programmable by built-in city database or by entering latitude and longitude, plus a sunrise or sunset offset to adjust for local geography. • Panel current ratings are listed for continuous operation. ULR Listed specifically for each light source. • Arcless-relay air gap-off switches (one per load circuit) ensure open load circuits when off function selected. Eliminate arcing at mechanical contacts when loads are switched Control Station Devices • One to seven button seeTouch® wallstations. • Buttons are programmable to select scenes or patterns, toggle circuits, or activate delay-to-off. • Buttons are programmed at the LCP128T controller. • Key switch control is also available. • Controls are powered by and communicate via the LCP128T low-voltage communication link. • OMX-CCO-8 integrates third party motorized window treatments or A/V equipment. • OMX-AV interfaces with occupant or photo sensors. • OMX-RS232 interfaces the LCP128T system to a PC, touchscreen, or building management system. • ODMX-512 interfaces to theatrical stageboards. • See specific product specification sheets for further details. LCP Spec Grade Panels Short Circuit Current Ratings (other ratings available) Panel Type V~ Standard SCCR Rating LCP Spec Grade Main Lug (standard and large size) 120, 277 25,000 A LCP Spec Grade Main Breaker (standard size) 120 10,000 A LCP Spec Grade Main Breaker (standard size) 277 18,000 A LCP Spec Grade Main Breaker (large size) 120 25,000 A LCP Spec Grade Main Breaker (large size) 277 25,000 A ® Job Name: Job Number: S p e c i f i c at i o n S u b m i t ta l Model Numbers: Page 4 Dimming & Switching Systems LCP128TM Spec Grade Power Equipment 369-642a 5 06.04.12 seeTouch® Wallstations Description • Each seeTouchR wallstation features engraved, backlit buttons allowing quick and easy recall of lighting presets, even in low light conditions. • Button functionality is fully programmable. Specifications • Low-voltage type IEC PELV/NECR Class 2 Operating voltage: 24 V-. • Meets IEC 801-2. Tested to withstand 15 kV electrostatic discharge without damage or memory loss. • Faceplate snaps on with no visible means of attachment. • Terminals accept up to two 18 AWG (1.0 mm2) wires typical. • Environment: 32 to 104 °F (0 to 40 °C). Relative humidity less than 90% non-condensing. Off seeTouchR Wallstation (SO-4SN-WH-EGN) seeTouchR Models • Models available with one to seven buttons, with or without raise/lower. • Use SO series model numbers. • Available with all standard colors and engraving. • Available with built-in contact closure inputs or with optional occupant sensor inputs. Button Programming • Each button may be programmed for scene selection, toggle, delay-to-off, raise, or lower functionality. • Button programming can be used to provide specialized manual control of multiple areas. Typical wallbox dimensions: 3.74 in (95 mm) H x 2.17 in (55 mm) W x 2.75 in (70 mm) D. Button Engraving Custom engraving is available using button/ faceplate replacement kits. To order, contact Lutron Customer Service at 1.888.LUTRON1 (1.888.588.7661). ® Job Name: Job Number: S p e c i f i c at i o n S u b m i t ta l Model Numbers: Page 5 Dimming & Switching Systems LCP128TM Spec Grade Power Equipment 369-642a 6 06.04.12 Feed-Through Model Numbers Branch Circuit Breaker Model Numbers Example Example L C P 1 2 - 1 2 0 F T M L L C P 2 4 - 1 2 0 4 M L - 2 0 Number of Circuits in Panel Number of Circuits in Panel Feed-Through Type Feed Voltage Voltage Number of Circuits in Panel Feed Indicates number of switching circuits in the panel: 8, 12, 16, 20, or 24 4 for 3 phase 4 wire 120/208 V Feed Type 277 for 277 V M or ML for main lugs 16 A per circuit Frequency - All Model Numbers and Voltages 50/60 Hz Output Voltages 120 V or 277/480 V 3 for 1 phase 3 wire 120/240 V 120 for 120 V Load Circuit Rating Branch Circuit Rating Input Ratings 2 for 1 phase 2 wire 120 V Voltage Feed Type or 277 V DTML for dual tap main lugs Mxxx for main breaker (xxx = breaker size in amps) Branch Circuit Rating 20 for 20 A branch circuit breakers 20 A branch circuit breakers have a 16 A continuous load rating or 277 V ® Job Name: Job Number: S p e c i f i c at i o n S u b m i t ta l Model Numbers: Page 6 Dimming & Switching Systems LCP128TM Spec Grade Power Equipment 369-642a 7 06.04.12 Ratings: LCP8-24 Spec-Grade Only standard panels listed; consult Lutron for further options 120-127 V Power Panel Branch Ratings Number of Circuits LCP8 LCP12 LCP16 LCP20 LCP24 1 2 Feed Type Panel Feed Maximum Feed Circuit Breakers1 Maximum Dimmed Hot Load2 1Ø, 2 W Main Lugs Only 175 A 20 A 2000 W/VA 1Ø, 3 W Main Lugs Only Dual Tap Main Lugs 80 A Main Breaker 175 A 225 A 80 A 20 A 20 A 20 A 2000 W/VA 2000 W/VA 2000 W/VA 3Ø, 4 W Main Lugs Only Dual Tap Main Lugs 60 A Main Breaker 175 A 225 A 60 A 20 A 20 A 20 A 2000 W/VA 2000 W/VA 2000 W/VA 1Ø, 3 W Main Lugs Only Dual Tap Main Lugs 175 A 225 A 20 A 20 A 2000 W/VA 2000 W/VA 3Ø, 4 W Main Lugs Only Dual Tap Main Lugs 80 A Main Breaker 175 A 225 A 80 A 20 A 20 A 20 A 2000 W/VA 2000 W/VA 2000 W/VA 1Ø, 3 W Main Lugs Only Dual Tap Main Lugs 175 A Main Breaker 175 A 225 A 175 A 20 A 20 A 20 A 2000 W/VA 2000 W/VA 2000 W/VA 3Ø, 4 W Main Lugs Only Dual Tap Main Lugs 125 A Main Breaker 175 A 225 A 125 A 20 A 20 A 20 A 2000 W/VA 2000 W/VA 2000 W/VA 1Ø, 3 W Main Lugs Only 225 A 20 A 2000 W/VA 3Ø, 4 W Main Lugs Only Dual Tap Main Lugs 150 A Main Breaker 175 A 225 A 150 A 20 A 20 A 20 A 2000 W/VA 2000 W/VA 2000 W/VA 1Ø, 3 W Main Lugs Only 225 A 20 A 2000 W/VA 3Ø, 4 W Main Lugs Only Dual Tap Main Lugs 150 A Main Breaker 175 A 225 A 175 A 20 A 20 A 20 A 2000 W/VA 2000 W/VA 2000 W/VA 20/16 A, 15/12 A continuous load rating. Measured current will not exceed continuous load rating due to voltage drop in the dimmer. ® Job Name: Job Number: S p e c i f i c at i o n S u b m i t ta l Model Numbers: Page 7 Dimming & Switching Systems LCP128TM Spec Grade Power Equipment 369-642a 8 06.04.12 Ratings: LCP8-24 Spec-Grade Only standard panels listed; consult Lutron for further options 277 V Power Panel Branch Ratings Number of Circuits LCP8 1 2 Feed Type Panel Feed Maximum Feed Circuit Breakers1 Maximum Dimmed Hot Load2 1Ø, 2 W Main Lugs Only 175 A 20 A 4500 W/VA 3Ø, 4 W Main Lugs Only Dual Tap Main Lugs 60 A Main Breaker 175 A 225 A 60 A 20 A 20 A 20 A 4500 W/VA 4500 W/VA 4500 W/VA LCP12 3Ø, 4 W Main Lugs Only Dual Tap Main Lugs 80 A Main Breaker 175 A 225 A 80 A 20 A 20 A 20 A 4500 W/VA 4500 W/VA 4500 W/VA LCP16 3Ø, 4 W Main Lugs Only Dual Tap Main Lugs 125 A Main Breaker 175 A 225 A 125 A 20 A 20 A 20 A 4500 W/VA 4500 W/VA 4500 W/VA 20/16 A, 15/12 A continuous load rating. Measured current will not exceed continuous load rating due to voltage drop in the dimmer. ® Job Name: Job Number: S p e c i f i c at i o n S u b m i t ta l Model Numbers: Page 8 Dimming & Switching Systems LCP128TM Spec Grade Power Equipment 369-642a 9 06.04.12 LCP8-24 Spec-Grade Panel Dimensions Dimensions shown as: in (mm). 28 (711) Suggested feed wiring entry; punch cover 4 (100) Suggested feed wiring entry; punch cover Top View 2 (50) 2 (50) Removable top cover is shippedthe box with the panel. 37 (940) Left Side 35 (889) Front View 33 (838) Right Side 13 (330) 2(50 ) 12 (304) Bottom View 12 (304) Required control wiring entry Keyhole accepts a maximum 5/16 in (8 mm) mounting bolt (1/4 in [M8] recommended). IEC PELV/NECR Class 2 entry knockout is 7/8 in (22 mm) diameter. Notice: This equipment is air-cooled. Vents must not be blocked or the warranty will be voided. ® Job Name: Job Number: S p e c i f i c at i o n S u b m i t ta l Model Numbers: Page 9 Dimming & Switching Systems LCP128TM Spec Grade Power Equipment 369-642a 10 06.04.12 Panel Mounting: LCP8-24 Spec-Grade Front View Side View Notes Wiring raceway Load Wiring (top entry) Feed Wiring (top entry) 12 in (305 mm) minimum IEC PELV/ NECR Class 2 wiring to controls • For Indoor Use Only. NEMA, Type 1 enclosure, IP20. • Relative humidity must be <90% non-condensing. • Panel generates heat. Mount where ambient temperature is 32 to 104 ºF (0 to 40 ºC). • Reinforce wall structure for panel weight and local codes. • Mount within 7º of true vertical. • Panel clearances are 12 in (305 mm) above and below and 0in to each side. Allow room for IEC PELV/NECR Class 2 clearance. Panel 12 in (305 mm) Air flow minimum clearance Wall Max. BTUs/Hour (Kcal/Hour) Weight without Packaging lb (kg) LCP8 1365 (343.98) 115 (52) LCP12 2045 (515.34) 120 (54) LCP16 2725 (686.70) 145 (66) LCP20 3405 (858.06) 160 (73) LCP24 4085 (1029.42) 175 (80) Notice: Dimming panels will hum slightly and internal relays will click while in operation. Mount where audible noise is acceptable. Notice: Mount panel so line (mains) voltage wiring will be at least 6 ft (1.8 m) from sound or electronic equipment and its wiring. Notice: This equipment is air-cooled. Vents must not be blocked or you will void the warranty. ® Job Name: Job Number: S p e c i f i c at i o n S u b m i t ta l Model Numbers: Page 10 Dimming & Switching Systems LCP128TM Spec Grade Power Equipment 369-642a 11 06.04.12 Panel Mounting: LCP8-24 Spec-Grade At least 8 ft 8 in (265 cm) between floor and suspended ceiling is required for this layout. Front View Side View Wiring raceway Load Wiring Feed Wiring 12 in (305 mm) minimum 8 ft 8 in (265 cm) minimum to ceiling IEC PELV/ NECR Class 2 wiring Air flow 7 ft 55 in (228 cm) to mounting holes 6 ft 6 in (195 cm) NEC® breaker height limit IEC PELV/NECR Class 2 wiring 3 ft 45 in (103 cm) to mounting holes 6 in (152 mm) minimum* Air flow *6 in (152 mm) approved for this layout only. Warning: Shock Hazard. To avoid the risk of electric shock, install panels where they will not get wet. Water damages panels. ® Job Name: Job Number: S p e c i f i c at i o n S u b m i t ta l Model Numbers: Page 11 Dimming & Switching Systems LCP128TM Spec Grade Power Equipment 369-642a 12 06.04.12 Wiring Overview: LCP8-24 Spec-Grade Typical Load Circuit Wire Sizes • Power Feed Standard Main Lugs 14 AWG (2.0 mm2) to 2/0 AWG (70.0 mm2) • Power Feed Dual Tap Main Lugs 6 AWG (10.0 mm2) to 4/0 AWG (120 mm2) • Neutral Feed: 6 AWG (10.0 mm2) to 350 MCM (177.0 mm2) • Dimmed Hot/Live: 14 AWG (2.0 mm2) to 10 AWG (4.0 mm2) • Load Neutral: 14 AWG (2.0 mm2) to 6 AWG (10.0 mm2) Load Neutral Load Feed Wiring Power Feed (Hot/ Live) Wiring Tips • • • • • Wire the LCP8-24 similar to wiring a lighting Distribution Panel: Run feed and load wiring. No other wiring or assembly required. Common neutrals are not permitted. Run separate neutrals for each load circuit. The LCP8-24 can provide temporary lighting. Wire all loads. Do not remove the bypass jumpers that protect the dimming modules. Use branch circuit breakers to switch lights on and off. ® Job Name: Job Number: S p e c i f i c at i o n S u b m i t ta l Model Numbers: Neutral Feed Dimmed Hot/Live Bypass jumpers Do not remove Terminal block Branch circuit breakers IEC PELV/ NECR Class 2 wiring Page 12 Dimming & Switching Systems LCP128TM Spec Grade Power Equipment 369-642a 13 06.04.12 100-127 V~ and 277 V~ Load Circuits (LCP8-24 Spec-Grade) Incandescent Load Types Hi-lume® FDB or Eco-10® fluorescent dimming ballasts Dimmed Hot (DH) must be used for non-dim loads whether they will be dimmed or switched Bypass jumper Load terminals DH SH H DH SH H Hi-lumeR or Eco-10R FDB ballast Dimmable or non-dim load Neutral bus Ballast Neutral bus Fluorescent lamp TVM Load Types ELV Load Types TVM Load terminals Bypass jumper L DH SH H N + Ballast – + 1 – Dimmed Hot (DH) must be used for non-dim loads whether they will be dimmed or switched Bypass jumper Neutral bus Load Neutral bus Load Circuits with Emergency Battery Pack Wiring LCP Dimming Panel Neutral (White) Dimmed Hot (Orange) Switched Hot (Black) Load Terminals Load terminals DH SH H + 2 – N Load terminals Bypass jumper Dimming Ballast Blue Blue Red Red Yellow Blue Black (277 V ) To Unswitched AC Blue/White Orange (120 V ) Yellow Emergency White Yellow/Black Ballast To Neutral Red Lamp 1 Lamp 2 (Emerg.) } Indicator Battery Light Connector DH SH H ® Job Name: Job Number: S p e c i f i c at i o n S u b m i t ta l Model Numbers: Page 13 Dimming & Switching Systems LCP128TM Spec Grade Power Equipment 369-642a 14 06.04.12 IEC PELV/NECR Class 2 Wiring The LCP128T system communicates to control stations using a IEC PELV/NECR Class 2 low-voltage link. Control stations include wallstations, contact closure input and output devices, and RS232 interfaces. • • • • • • • Wire the IEC PELV/NECR Class 2 link according to the following guidelines: Link must be daisy chained. Must run in separate trough from line (mains) voltage. Link must be less than 2000 ft (600 m) long. Make wire connections inside the wallbox and LCP128T panel. Install Link Terminators (LT-1) at the start and end of the IEC PELV/NECR Class 2 daisy-chained link. The order of controls on the control link is not important. Use LutronR GRX-CBL-46L cable or equivalent. 2000 ft (600 m) maximum LT-1 Control Stations: Wallstations, contact closure input, contact closure output, and RS232 devices LT-1 Note: Link Terminators (LT-1) are required at the start and end of the LCP128T IEC PELV/NECR Class 2 link. LCP128T Panels Maximum total length of the control link is 2000 ft (600 m). This distance is based on proper shielding of the twisted/ shielded pair, proper wire size, and the use of link terminators (LT-1) at each end of the link. If unapproved cable or smaller wire is used, control link length must be de-rated according to the following chart: Terminal 1 & 2 Wire Sizes Maximum Control Link Length 12 AWG (4.0 mm2) 2000 ft (600 m) 14 AWG (2.5 mm2) 1400 ft (425 m) 16 AWG (1.5 mm2) 900 ft (275 m) 18 AWG (1.0 mm ) 600 ft (180 m) 2 ® Job Name: Job Number: S p e c i f i c at i o n S u b m i t ta l Model Numbers: Notice: If Link Terminators (LT-1) are not used or improper wiring topology is employed, the system will not communicate properly. Page 14 Dimming & Switching Systems LCP128TM Spec Grade Power Equipment 369-642a 15 06.04.12 IEC PELV/NECR Class 2 Wiring Panel to Panel and Panel to Control Stations Control Power: (2) 12 AWG (2.5 mm2) 1: Common 2: 24 V Emergency Sense: (1) 18 AWG (1.0 mm2) 5: Sense Line 1 1 2 2 3,4 ,D 3,4,D To additional LCP128T panels 5 1 2 3 4 D 5 CCI1 COM CCI2 COM 1 2 3 4 D 5 LCP128T Controller CCI1 COM CCI2 COM To LCP128T control stations Control Data: (1) twisted shielded pair 22 AWG (0.625 mm2) 3: MUX 4: MUX D: Drain/Shield LCP128T Controller Wiring Notes: • Use a wire connector to attach one 18 AWG (1.0 mm2) wire for Common (terminal 1) and one 18 AWG (1.0 mm2) wire for 24 V (terminal 2) from the IEC PELV/NECR Class 2 link to the control. Two 12 AWG (4.0 mm2) wires cannot both be terminated on the control station. Maximum wire length from link to control is 8 ft (2.5 m). • Only connect the Drain/Shield wire (bare copper) to terminal ‘D’ in LCP128T panels. Maintain the shield throughout the link but do not allow it to touch ground (earth) or wallstation circuitry. ® Job Name: Job Number: Drain wire 1 23 4D 5 4 3 2 1 S p e c i f i c at i o n S u b m i t ta l Model Numbers: Control station terminal Page 15 Dimming & Switching Systems LCP128TM Spec Grade Power Equipment 369-642a 16 06.04.12 IEC PELV/NECR Class 2 Wiring for ODMX-512 • Make daisy-chain connections to the low-voltage IEC PELV/NECR Class 2 MUX link terminals on the front of ODMX-512 interface • Do not use T-taps; run all wires in and out of terminal block. • Each terminal accepts up to two 18 AWG (1.0 mm2) wires. To additional wallstations/control interfaces (16 maximum; three from one control unit without external 12 V power supply) 1000 ft (305 m) maximum COM Data Data + LutronR Cable GRX-CBL-46LS 1 2 3 4 5 6 4 5 1 2 3 DMX theatrical control Nova T*R style wall jack 1 2 3 COM - + DMX 512 INPUT CONTROL EXT LINK SW ODMX-512 CCI1 COM CCI2 COM 1 2 3 4 D 5 IEC PELV/NECR Class 2 Terminal Connections Data Link - (1) twisted, shielded pair 18 AWG (1.0 mm2) 3: MUX 4: MUX D: Drain/ Shield (2) 12 AWG (2.5 mm2) SW1 (2) 12 AWG (2.5 mm2) ® Job Name: Job Number: 2 3 4 5 1 2 3 4 1 2 3 4 +V MUX MUX J1 1 2 3 4 5 DMX ZONE SELECT EARTH CONTROL LINK (1) 18 AWG (1.0 mm2) SW2 1 LINK COM (1) 18 AWG (1.0 mm2) LED1 LED2 CONTROL LINK 5 6 J2 6 1 COM EXT SW IEC PELV/NECR Class 2 control wiring 1: Common 2: 24 V 1 COM DMX 512 INPUT EXT SW 5 J3 • Two 12 AWG (2.5 mm2) conductors for common (terminal 1) and 24 V (terminal 2). These will not fit in terminals. Connect as shown. • One shielded, twisted pair 18 AWG (1.0 mm2) for data link (terminals 3 and 4). • Connect Drain/Shield as shown. Do not to Ground (Earth) or wallstation/control 2 connect 3 Interfaces. Connect the bare drain wires and cut off the outside shield. • Do not connect the extra 18 AWG (1.0 mm2) wire to the ODMX-512. Connect only to LCP128T panels as a “sense line” for emergency (essential) lighting. 2 3 DMX 512 INPUT ODMX-512 S p e c i f i c at i o n S u b m i t ta l Model Numbers: Page 16