Liebert ® K e e p i n g B u s i n e s s i n B u s i n e s s™ ® Islatrol Series LIEBERT : A CLEAR PATH TO THE FUTURE YOU CAN TRUST THE LIEBERT NAME For a quarter of a century Liebert has been an industry leader, renowned world-wide for our advanced computer protection equipment, including air conditioning, UPS, battery and security and environmental control systems. Today we are one of the largest suppliers of equipment for telecommunication and computer installations, clean rooms, high security areas and many other critical applications, with an impressive customer list which includes thousands of companies, large and small, all around the world. We place a high priority on using the most advanced technology, designed and built to the stringent ISO9000 standard, and we continue to invest heavily in research and development. All our systems are built to make the most efficient use of energy and to have the highest level of reliability. And all our products are backed by the international resources of the Liebert Corporation, the name you can trust. ISLATROL® AND OTHER LIEBERT POWER PROTECTION PRODUCTS ARE AVAILABLE FROM: While every precaution has been taken to ensure accuracy and completeness in this brochure, Liebert Corporation assumes no responsibility, and disclaims all liability for damages resulting from use of this information or for any errors or omissions. © 1997 Liebert Corporation. All rights reserved throughout the world. Specifications subject to change without notice. All names referred to are trademarks or registered trademarks of their respective owners. SLE IS E.2 Printed in Italy L I E B E R T C O R P O R AT I O N LIEBERT EUROPE 1050 DEARBORN DRIVE P.O. BOX 29186 COLUMBUS, OHIO 43229 USA TEL: +1 614 888 0246 FAX: +1 614 841 6022 VIA G. ROSSINI 6 20098 S. GIULIANO MILANESE (MI) ITALY TEL: +39 02 982501 FAX: +39 02 9844633 LIEBERT WEB SITE LIEBERT UK http://www.liebert.com GLOBE PARK, MARLOW BUCKINGHAMSHIRE, SL7 1YG UNITED KINGDOM TEL: +44 (0)1628 403200 FAX: +44 (0)1628 403203 P O W E R P R O T E C T I O N Liebert ® ® Islatrol Series HIGH ENERGY CURRENT SUPPRESSOR WITH ACTIVE TRACKING ® COMPREHENSIVE PROTECTION AGAINST THE FULL SPECTRUM OF TRANSIENT VOLTAGES ■ Maximum protection against both high and low voltage transients ■ High impact casing with epoxy encapsulation ■ MTBF greater than 100,000 hours ■ Protect against the immediate and long term effects of normal mode noise ■ Response time less than 1 nanosecond in normal mode ■ The industry standard Active Tracking® Filter for OEMs ■ Liebert is an ISO9000 company L P I E B E R T O W E R P C O R P O R A T I O N R O T E C T I O N THE CLEAR NEED FOR CLEAN POWER High energy transients in the AC power voltage are a small appliances are switched on. Over the course of leading source of microprocessor malfunctions. And time these lower energy disturbances can cause erratic although the electrical service gateway to your equipment performance, data loss, or sudden network may be insulated against catastrophic over- component failure. voltage conditions by standard panel protectors, they That is why hospitals, data centres, industrial process cannot alone provide complete protection. lines and computer networks and other critical systems For example, continual lower-energy transients have a rely on the complete protection of the Liebert Islatrol® more insidious, cumulative effect, and may actually family of transient voltage surge suppression products originate within your site when electrical motors or and Active Tracking® Filters. Industrial Electronics Factories require noise-free voltage to keep process control machines running at maximum productivity and minimum downtime. Broadcast& Transmission Television and radio broad-casters as well as voice and data networks count on high quality power for proper operation. 2 Computer Equipment Offices and retail stores demand computer-grade power to maintain the integrity of memory logic circuits and data. Medical Electronics Hospitals need clean power to produce CAT scans and MR images of consistently high diagnostic quality. L I E B E R T C O R P O R A T I O N ISLATROL PLUS VOLTAGE SURGE SUPPRESSORS WITH ACTIVE TRACKING FILTER ® ® ISLATROL PLUS® VOLTAGE SURGE SUPPRESSORS And most have no attenuating effect on destructive, The Islatrol Plus® family of transient voltage surge But Liebert’s Islatrol Plus® Transient Voltage Surge suppression units combine rugged, high-energy current Suppressor provides protection against the full lower-voltage transients. diverters with Liebert’s acclaimed Active Tracking Filter. spectrum of voltage transients, including both the The result is a product range capable of protecting relatively rare, high energy disturbances and the much against the full spectrum of voltage transients. more frequent problems of low-energy and high- ® Most conventional surge suppressors only address the frequency noise. problem of the relatively rare high-energy transient. It also fills-in short term notches up to 50 nanoseconds Although these devices will limit voltages from a and offers unequalled ANSI C62.41 Category A catastrophic high-energy event such as lightning strike, attenuation (ringwave noise), to provide total they can still let through transients of at least 300V, protection and exceptionally clean and reliable AC more than enough to upset or damage sensitive circuits. power for sensitive electronics. Maximum Protection Against Both High and Low Voltage Transients High Voltage spikes appearing on 230V, 50Hz sine wave. Clamping devices only shorten peak spike excursions. Islatrol® reduces spikes to levels which will not affect load side equipment. Lower voltage transients (high frequency noise) appearing on 230V, 50Hz sine wave. Clamping devices have no attenuating effect on lower voltage transients. Islatrol® eliminates lower voltage transients, ensuring that load side equipment is not affected. 3 L P I E B E R T O W E R C P O R P O R A T I O N R O T E C T I O N DURABLE, LONG LASTING PROTECTION THE ISLATROL PLUS® SYSTEM DESIGN ■ Pulse Capacitors Handle low level EMI/RFI signals and limit the rate of increase of high rise-time events to provide extremely quick response. Pulse capacitors on both the input and output terminals ensure maximum high-frequency, bidirectional rejection. ■ High-energy MOVs Arrays Metal-oxide varistor arrays on both line and load sides provide optimum shunt capability, with high energy surge currents from either side clamped to low peak voltages. ■ Series Blocking Inductors The heart of the Active Tracking® Filter design, the inductors effectively isolate voltage transients between each terminal strip of the unit. Their magnetic cores efficiently store and release energy to smooth the current through the unit. ■ Shunt Absorbing Circuitry Line sine wave tracking capacitive shunt networks are connected across the line and load sides of the Islatrol Plus®. They absorb harmonics produced during MOV conduction. With the series inductors they also form a Pi-selection low pass filter. ■ Epoxy Encapsulation Provides high dielectric isolation between components and prevents premature ageing of components from electrical or mechanical stress, allowing continuous operation in harsh environments. Pulse Capacitor Line side high frequency absorption MOV Array Line side current diversion high energy, 150 MCOV Line Shunt Absorbing Components Line side sine wave tracking circuitry Series Blocking Inductors Voltage blocking current smoothing inductors Load Shunt Absorbing Components Load side sine wave tracking circuitry MOV Array Load side current diversion high energy, 150 MCOV capacity Pulse Capacitor Load side high frequency absorption Epoxy Encapsulation Dielectric Insulation Unit shown partially encapsulated 4 L I E B E R T C O R P O R A T I O N PROTECTING INVESTMENTS AND MAXIMISING PRODUCTIVITY ISLATROL ACTIVE TRACKING® FILTERS The vast majority of power-line disturbances are action is required to ensure trouble-free operation of caused by normal mode noise - the noise between sensitive microprocessor-based equipment, the original current-carrying conductors. Liebert’s Islatrol Plus Islatrol Active Tracking® Filter offers a level of protection Active Tracking® Filter is the only system of its kind to which goes far beyond minimum test standards. continuously protect sensitive electronics from both And as an AC power conditioning component for the immediate and long-term effects of normal Original Equipment manufacturers, it is now the mode noise. industry standard. Relying on Islatrol Plus® filters guards investments in Islatrol Plus® filters provide dependable, continuous equipment and components, reduces the risk of protection, irrespective of the intensity and frequency unplanned downtime and additional service costs, and of the transients. Where voltage-clamping devices helps guard against software and data errors. could deteriorate under frequent transient exposure, In any application where normal-mode, full filtering the proven longevity and durability of Islatrol Plus® filters makes then the clear choice of both OEMs and end-users. A RANGE TO MEET YOUR SPECIFIC REQUIREMENTS Islatrol Plus Active Tracking® Filters are available in a range of configurations to meet any specific power conditioning requirement. ■ Single Phase Units are available in both hardwired and line-cord ■ Islatrol Plus® Three Phase Filters receptacle configurations, from 0.5 amps to use Active Tracking® technology to protect critical 200amps, 50/60Hz, 120VAC,240VAC and 480VAC. environments, including hospitals, processing They can also be supplied as printed circuit board centres and computer-controlled manufacturing units, DC units for DC voltage environments and operations. They are available in a range of ratings 400Hz units for commercial and military applications. from 15amps to 1200amps. 5 L P I E B E R T P O W E R C O R P O R A T I O N R O T E C T I O N ISLATROL ® ® ACTIVE TRACKING FILTERS TECHNICAL SPECIFICATIONS ■ Input Voltage 120VAC Models 240VAC Models 480VAC Models ■ Operating Temperature Range -40°C to +70°C at full load. 0-150VRMS 0-275VRMS 0-520VRMS ■ Mean Time Between Failure (MTBF) Greater than 100,000 hours (MIL-217F). ■ Line Frequency 50/60Hz (400Hz also available). ■ Response Time Less than 1 Nanosecond. ■ Safety Approvals UL1283 listed or recognised, Many units CSA. CE marked complies with EMC and Low Voltage Directives. ■ Load Regulation Better than 1% from no load to full load. ■ Load Surge Current Rating 10 MSEC 20 x Nominal 1 SEC 5 x Nominal 5 SEC 3 x Nominal Weight (kg) l-100 l-200 2.63 x 1.87 x .87 0.91 1.0 l-101 l-201 3.00 x 2.02 x 2.20 0.91 2.5 l-102 1-202 LRI-102 3.94 x 2.88 x 1.82 5.00 x 4.25 x 1.97 0.91 1.36 l-105 l-205 LRI-105 l-405 3.94 x 2.88 x 1.82 5.00 x 4.25 x 1.97 10 x 8 x 6 0.91 1.36 14.51 l-407 5.00 x 4.25 x 1.90 6.25 x 3.75 x 2.27 10 x 8 x 6 1.36 1.81 14.51 l-415 6.80 x 5.30 x 2.40 7.58 x 4.58 x 2.61 10 x 8 x 6 2.27 2.27 14.51 l-430 8.44 x 7.44 x 4.18 10 x 8 x6 3.63 14.51 75 15 30 l-107 l-207 LRI-107 l-115 LRI-115 l-130 l-215 1-230 50 l-150 l-250 l-450 14 x 12 x 6 17.24 100 l-1100 l-2100 l-4100 20 x 16 x 8 38.56 l-4200 24 x 20 x 10 49.90 200 6 Size (L,W,H) .50* 5.0 ■ Transient Reduction Minimum of 40db from 50Hz through 50MHz. Attenuation is greater than 50db to the surge withstand capability ringwave test IEEE C62.41, Category “A” and “B”. Three Phase Models* Single Phase Models Amps 120VAC 240VAC 480VAC ■ Packaging Single Phase units through 30 amps housed in Black, high impact plastic case, vacuum impregnated magnetics, epoxy encapsulated; Single Phase greater than 30 amps, 480VAC, and Three Phase units housed in Nema 12 enclosures. Amps 120/280 or 120/240 VAC 15 1-3-215 30 1-3-230 50 1-3-250 100 1-3-2100 200 1-3-2200 400 1-3-2400 600 1-3-2600 1000 1-3-21000 1200 1-3-21200 277/480 or 440/480 VAC 1-3-415 1-3-430 1-3-450 1-3-4100 1-3-4200 1-3-4400 1-3-4600 1-3-41000 1-3-41200 Size (L,W,H) Weight (kg) 14 x 12 x 6 14 x 12 x 6 14 x 12 x 6 20 x 16 x 8 20 x 16 x 8 24 x 20 x 10 72 x 36 x 18 90 x 46 x 28 90 x 46 x 28 17.24 17.24 38.56 38.56 49.90 226.80 226.80 385.56 385.56 *Must specify Wye or Delta connections Typical Islatrol Test Results IEEE Category A Ringwave 6KV, 200A, 100khz Normal Mode l-100 6.0 l-101 5.5 l-102 3.6 l-107 3.6 l-115 2.8 l-120 1.0 l-130 1.4 l-200 5.2 l-201 5.1 l-202 3.4 l-205 2.4 l-207 3.6 l-215 3.0 l-230 3.0 IEEE Category B Ringwave 6KV, 500A,100KHz Normal Mode 6.2 6.2 3.8 3.8 3.5 3.0 1.2 2.0 5.5 3.6 2.6 3.8 3.2 3.6 Notes: All measurements in volts. IEEE test results with no AC applied. Normal mode - L-N or L1-L2. DC Units Available from .25 to 100 amps from 0-100VDC, please consult factory. For voltages, frequencies, or applications not listed, please consult factory. L I E B E R T C O R P O R A T I O N ISLATROL PLUS ® TRANSIENT VOLTAGE SURGE SUPPRESSOR WITH ACTIVE TRACKING FILTER ® ■ Operating Temperature Range -40C to +45C at full load. Derate linearly to 60% at +70C. TECHNICAL SPECIFICATIONS ■ Input Voltage 120VAC Models: 240VAC Models: 0-135VRMS 0-260VRMS ■ Mean Time Between Failure (MTBF) Greater than 100,000 hours (MIL-217F) ■ Maximum Continuous Operating Voltage (MCOV) 120VAC Models: 150VRMS 240VAC Models: 275VRMS ■ Line Frequency 50/60 Hz: 40-70 Hertz ■ Response Time Normal Mode: Common Mode: Less than 1 Nanosecond Less than 5 Nanosecond ■ Safety Approvals UL1283 (EMI/RFI Filter), UL1449, CSA. CE marked complies with EMC and Low Voltage Directives. ■ Load Regulation 1% total from no load to full load. ■ Load Surge Current Rating 10 MSEC: 100 x Nominal 1 SEC: 10 x Nominal 10 SEC: 5 x Nominal ■ Packaging Black, high impact plastic case. Vacuum impregnated magnetics. Epoxy encapsulated. ■ Frequency Response EMI/RFI small signal RFI or large signal transients. Normal Mode Common Mode Forward-Reverse Forward-Reverse 100KHz to 50kHz 5MHz to 50MHz 60db minimum 60db minimum ■ Surge Energy Capability 120VAC Models: 480 Joules Total (L-N, L-G, N-G): 160 Joules 240VAC Models: 840 Joules Total (L1-L2, L1-G, L2-G): 280 Joules ■ Peak Surge Current Capability (8 x 20us) 6500 Amperes: 39,900 Amperes total Ordering Information Amps VAC Model# Dimensions (L,W,H) Weight (kg) 2.5 120 240 120 IC+102 IC+202 LRIC+102 4.00 x 2.88 x 1.81 4.00 x 2.88 x 1.81 4.50 x 3.00 x 1.88 0.91 0.91 1.36 5.0 120 240 120 IC+105 IC+205 LRIC+105 4.00 x 2.88 x 1.81 4.50 x 4.50 x 2.50 4.50 x 4.50 x 2.38 0.91 0.91 1.36 7.5 120 240 120 IC+107 IC+207 LRIC+107 4.50 x 4.50 x 2.50 6.00 x 4.50 x 2.50 6.00 x 4.50 x 2.38 1.81 1.81 2.27 15 120 240 120 IC+115 IC+215 LRIC+115 6.00 x 4.50 x 2.50 7.50 x 4.50 x 2.50 7.50 x 4.50 x 2.38 2.27 2.27 2.72 30 120 240 IC+130 IC+230 7.50 x 4.50 x 2.50 7.50 x 4.50 x 2.50 3.18 3.18 IC+ Models - hardwired with barrier strips and mounting flange LRIC+ Models - single 5-15R receptacle with 5’5-15P plug Test Results: IEEE Category A Ringwave 6KV, 200A, 100KHz Test Results: IEEE Category B Impulses 6KV, 3KA 8 x 20 µs Normal Common IC+ 102 1.0 302 LRIC+ 102 0.9 287 IC+ 105 0.7 292 LRIC+ 105 0.8 307 IC+ 107 0.7 302 LRIC+ 107 0.7 293 IC+ 115 0.7 304 LRIC+ 115 0.7 306 IC+ 130 0.5 306 IC+ 202 1.1 536 IC+ 205 1.5 628 IC+ 207 0.8 616 IC+ 215 0.6 572 IC+ 230 0.9 566 Normal Common IC+ 102 178 302 LRIC+ 102 188 285 IC+ 105 162 291 LRIC+ 105 191 300 IC+ 107 173 300 LRIC+ 107 190 298 IC+115 153 307 LRIC+ 115 149 309 IC+ 130 241 299 IC+ 202 302 532 IC+ 205 378 594 IC+ 207 336 596 IC+ 215 272 548 IC+ 230 342 578 All measurements in volts. IEEE test results with no AC applied. Normal Mode - L-N or L1-L2; Common mode - L-G, or L1-G, L2-G. 7