Pipe Mounting Kit Installation Instructions For Electric Heaters WARNING: If the heater is installed on a structure that is to be transported, provide additional support for the heater during transit. The suspended weight should not exceed 300lbs (136kg). Refer to the owner’s manual for mounting specifications and conditions. Check that your heater model number corresponds to the model number shown on the mounting kit carton. Installer required to supply: a) b) c) One piece of 3”, Schedule 40 or heavier, steel pipe cut to required length. Maximum length to be 25ft (7.6m). A method to fasten the Column Stabilizer Bracket to the supporting structure. Four 3/8” diameter grade 5 bolts are suggested, however, any method providing the same or greater strength may be used. A fastener to attach the Base Plate to a steel or wood floor. The kit provides a 3/8 UNC Expansion Bolt for concrete floors. STEP 1 STEP 2 Fasten Column Stabilizer Bracket to the wall using the installer supplied fastening method. The Column Stabilizer Bracket must be mounted at an appropriate height to support the top of the pipe. Install the Base Plate centered below the Column Stabilizer Bracket using installer supplied fasteners, or the supplied 3/8 UNC x 2-3/4 expansion bolt, washer and 3/8 UNC nut. To install the expansion bolt, drill a 3/8”(9.5mm) diameter hole a minimum of 2” (51mm) deep. Screw the nut with a washer onto the bolt, 1/8” (3mm) past the end. Drive the bolt through the base plate hole into the drilled hole so that the nut and washer are seated on the Base Plate . Turn nut until tight. 8” m) 3m 0 8” m) (2 3m (20 3-3/4" to 4-7/8" (96-124mm) ter en eC STEP 4 e Lin l Ho STEP 3 Using U-bolts, lock washers, and 3/8 UNC nuts, fasten Stabilizer Angle and Arm Assembly at their approximate final location on the 3” steel pipe. Leave nuts loose enough to permit parts to be moved to a final location after pipe is erected. CONTENTS Item Qty. Description Erect the pipe on Base Plate . Using two 3/8 UNC x 1 bolts, two flat washers per bolt, lock washers and 3/8 UNC nuts, fasten Stabilizer Angle to Column Stabilizer Bracket . Position Arm Assembly at final mounting height and tighten all U-bolts. 1 Mtg Attach Assy Bracket 1 Arm Assembly 1 Stabilizer Angle 1 Column Stabilizer Bracket 1 Base Plate 2 Bolt, 1/2 UNC x 1-1/4 8 Lock Washer, 3/8” 3 Lock Washer, 1/2” 3 U-Bolt, 3/8 UNC x 3-1/2 2 Bolt, 3/8 UNC x 1 1 Expansion Bolt, 3/8 UNC x 2-3/4 9 Nut, 3/8 UNC 5 Flat Washer, 3/8” 2 Nut, 1/2 UNC 1 Flat Washer, 5/8” 1 Bolt, 5/8 UNC x 1-1/4 1 Lock Washer, 5/8” STEP 5 Bolt Mtg Attach Assy Bracket to the heater using 1/2 UNC x 1-1/4 bolts, lock washers, and 1/2 UNC nuts. Mtg Attach Assy Bracket must be placed with the threaded hole closest to the control enclosure side of the heater. Control Enclosure Printed in Canada. Copyright 2007. All rights reserved. STEP 6 Lift the heater into place and fasten it to the Arm Assembly using a 5/8 UNC x 1-1/4 bolt, lock washer, and flat washer. This step will require more than one person due to the weight of the heater. Refer to the owner’s manual for the weight of the heater. Heater and arm assembly may be rotated, as indicated by arrows. 3” Sch. 40 steel pipe 25ft (7.6m) max. length e e Pip r Lin nte Ce (53 21” 4m m) r ate He vot Pi int o P Part No. 5750-2