iT600 Wiring Centre KL10RF 004_Layout 1 05/06/2014 15:24 Page 1 KL10RF Installation and wiring guide OPTIONAL HOT WATER TIMER (MODEL VS10WRF or VS20WRF) 2 1 L BATTERY POWERED PROGRAMMABLE ROOM THERMOSTAT VS20WRF) (MODEL VS20WRF MAINS POWERED PROGRAMMABLE ROOM THERMOSTAT (MODEL VS10WRF) N 2 1 L BATTERY POWERED PROGRAMMABLE ROOM THERMOSTAT MAINS POWERED PROGRAMMABLE ROOM THERMOSTAT N 2 1 L BATTERY POWERED PROGRAMMABLE ROOM THERMOSTAT MAINS POWERED PROGRAMMABLE ROOM THERMOSTAT N 2 1.5MM 2 3 CORE 1 L BATTERY POWERED PROGRAMMABLE ROOM THERMOSTAT N OPTIONAL PROGRAMMABLE ROOM THERMOSTAT RADIATOR ZONE 2 1 L 2 N 1.5MM 2 3 CORE 1 1.5MM 2 CABLE (INSTALLER SUPPLIED) 7 8 230V 1.5MM 2 CABLE FACTORY FITTED LINK FACTORY FITTED LINK FACTORY FITTED LINK OUT IN COLOURS ARE INDICATIVE ONLY. EXTRA CONNECTIONS MAY BE REQUIRED AS PER MANUFACTURERS INSTRUCTIONS IN OUT HW CYLINDER THERMOSTAT BR EA N OR GR HW MOTORISED VALVE IN OUT L OVERHEAT STAT N E IN OUT UFH PUMP BR EA N BOILER ENABLE 3 4 (INSTALLER SUPPLIED) OR GR FUSE UFH MOTORISED VALVE 6 OUT IN FUSE 5 - - - - - - - - THERMOSTAT NEUTRAL CONNECTIONS 9 L N L N ZONE 1 OPTIONAL CYLINDER STAT L N L N ZONE 2 L N L N ZONE 3 L N L N ZONE 4 + + + + + + + + + THERMOSTAT LIVE CONNECTIONS L N L N ZONE 5 L N L N ZONE 6 L N L N ZONE 7 L N L N ZONE 8 Meets the following EC Directives • Electro-Magntic Compatibility directive 2004 / 108 / EC • Low voltage Directive 2006/95/EC 1.5MM 2 CABLE (INSTALLER SUPPLIED) These instructions are applicable to the SALUS model stated above. 1.5MM 2 CABLE (INSTALLER SUPPLIED) SUPPLIED CABLES Warning 2 Optional wireless receiver RX10RF OPTIONAL UFH ZONE VALVE FOR RADIATORS GROUPS This product must be fitted by a competent person, and installation must comply with the guidance, standards and regulations applicable to the city, country or state where the product is installed. Failure to comply with the requirements of the relevant guidance, standards and regulations could lead to injury, death or prosecution. 13 AMP FUSED CONNECTION UNIT FUSED AT 3 AMPS Warning UNDERFLOOR HEATING MANIFOLD Always isolate the AC Mains supply before installing or working on any components that require 230 VAC 50Hz supply. 230V TO UFH PUMP 1.5MM 2 CABLE (INSTALLER SUPPLIED) For PDF Installation guide please go to www.salus-controls.com www.salus-controls.com Technical Helpline 00000 000000 Maintaining a policy of continued product development SALUS Controls plc reserve the right to change specification, design and materials of products listed on this installation guide without prior notice. Issue Date: June 2014 Document Number 00106 iT600 Wiring Centre KL10RF 004_Layout 1 05/06/2014 15:24 Page 2 KL10RF Installation and Wiring Guide Hot Water Connections 1 OPTONAL HOT WATER MOTORISED VALVE 5 8 Thermostat Connections OPTONAL UPH MOTORISED VALVE REMOVE LINK IF USED Optional Cylinder Thermostat: If connecting the cylinder thermostat directly to the timer then a link needs to be fitted between IN and OUT. Optional Hot Water Motorised Valve: Used if timed hot water is required. Optional Overheat Thermostat: Used for connecting a pipe thermostat to prevent over temperature water damaging sensitive floors. Remove the link and connect the pipe thermostat so it is Normally Closed. The pipe stat will open if overheating occurs and the UFH pump will stop running. Optional Boiler Enable: This Volt Free connection must come from the boiler thermostat connection, when any zone calls for heat the Boiler enable will close causing the boiler to run. If work is being carried out on the boiler then power to and from the switch will cease. (Do not connect to the boiler IN terminal by linking a 230V feed from the wiring centre) Optional UFH Motorised Valve: If a UFH motorised valve is fitted then remove the link between OR and GR. Optional Heat/Cool Changeover: This connection allows heat/cool changeover of all thermostats using a single external switch (installer supplied). Switch: Open-Heating Closed-Cooling Option 1 Connect Cylinder Thermostat to wiring centre IN OUT HW CYLINDER THERMOSTAT BR EA N OR GR HW MOTORISED VALVE 230V AC HW TIMER CONNECTION SL N L IN OUT L OVERHEAT STAT N E UFH PUMP IN OUT BOILER ENABLE BR EA N OR GR UFH MOTORISED VALVE THERMOSTAT CONNECTIONS 230V AC ZONE 1 SL N L ZONE 2 SL N L ZONE 3 SL N L OPTONAL HOT WATER MOTORISED VALVE ZONE 4 SL N L OPTONAL UPH MOTORISED VALVE REMOVE LINK IF USED Thermostat connections are to power the thermostats only, there is no switched live needed as this is done with a wireless signal. Power can therefore be supplied to the thermostat locally from any convenient power source if connecting to the wiring centre from the thermostat is difficult. Battery powered RF thermostats can also be used. These can be mixed with 230v RF thermostats or as an alternative. Option 2 IN OUT HW CYLINDER THERMOSTAT BR EA N OR GR IN OUT HW MOTORISED VALVE 230V AC HW TIMER CONNECTION SL N L OVERHEAT STAT L N UFH PUMP E IN OUT BOILER ENABLE BR EA N OR GR UFH MOTORISED VALVE 6 Fuses Coordinator Information Display 3 Ribbon Connection 2 THERMOSTAT CONNECTIONS 230V AC ZONE 1 SL N L ZONE 2 SL N L ZONE 3 SL N L ZONE 4 SL N L Sensor Terminals Can be used for external AIR, Floor sensor when configured as thermostat. Can also be used for cylinder thermostat when connected for HW. When using option 2 refer to device parameters on page xx of the manual. 9 7 Thermostat Zones Connect Cylinder Thermostat to RF Thermostat for wire free connection. A link will be needed between IN & OUT as shown by arrow. Motorised Valves, Pump, Boiler & Stat Connections Groups 1 2 Actuator Connections A Coordinator will be needed with all RF products. Actuator connections corresponding to the thermostat connections. Up to 2 cables can be used in each connection (4 Actuators per Zone) If more, that number needs to be connected, then an external junction box will be needed. A maximum of xxx actuators can be connected to a zone in this manner. After setting up the coordinator will assign the wiring centre number. This is because more than 1 wiring centre may be used on a project. Pressing the network button will illuminate the relevant number. The example shown is for wiring centre 1, if 1 & 2 are lit it would be wiring centre 2. In order for the wiring centre to be able to control UFH and Radiators, there is a need to turn off the UFH pump for a zone when that zone is to be used for radiators. Eg. When fitting a zone for radiators or towel rail then the Dip Switch for that zone should be switched to OFF. The Dip Switches for this are located under the front lid. When the zone switch is in the ON position the UFH pump will run when that zone is calling for heat along with the boiler. When it is in the OFF position then the UFH pump will not run but the boiler will fire. NETWORK BUTTON 4 Dip Switch Set Up Aerial Connection This must be carefully removed or replaced when removing or replacing the wiring centre cover, being careful to ensure the correct orientation. www.salus-controls.com Technical Helpline 00000 000000 There are three other function switches as well. Pump & Boiler delay: This gives a three minute delay to allow actuators to open before the boiler fires. Pump Only Delay: Delays only the UFH pump from firing for three minutes. Actuator NC or NO: This refers to Normally Open or Normally Closed. This should be set to NC for products.