iT600 Wiring Centre KL10RF 004_Layout 1 05/06/2014 15:24 Page 1
KL10RF
Installation and wiring guide
OPTIONAL
HOT WATER TIMER
(MODEL VS10WRF
or VS20WRF)
2
1
L
BATTERY POWERED
PROGRAMMABLE
ROOM THERMOSTAT
VS20WRF)
(MODEL VS20WRF
MAINS POWERED
PROGRAMMABLE
ROOM THERMOSTAT
(MODEL VS10WRF)
N
2
1
L
BATTERY POWERED
PROGRAMMABLE
ROOM THERMOSTAT
MAINS POWERED
PROGRAMMABLE
ROOM THERMOSTAT
N
2
1
L
BATTERY POWERED
PROGRAMMABLE
ROOM THERMOSTAT
MAINS POWERED
PROGRAMMABLE
ROOM THERMOSTAT
N
2
1.5MM 2 3 CORE
1
L
BATTERY POWERED
PROGRAMMABLE
ROOM THERMOSTAT
N
OPTIONAL
PROGRAMMABLE
ROOM THERMOSTAT
RADIATOR ZONE
2
1
L
2
N
1.5MM 2 3 CORE
1
1.5MM 2 CABLE
(INSTALLER SUPPLIED)
7
8
230V
1.5MM 2 CABLE
FACTORY
FITTED
LINK
FACTORY
FITTED
LINK
FACTORY
FITTED
LINK
OUT
IN
COLOURS ARE INDICATIVE ONLY.
EXTRA CONNECTIONS MAY BE REQUIRED
AS PER MANUFACTURERS INSTRUCTIONS
IN OUT
HW CYLINDER
THERMOSTAT
BR EA N
OR GR
HW MOTORISED VALVE
IN OUT
L
OVERHEAT STAT
N
E
IN OUT
UFH PUMP
BR EA N
BOILER ENABLE
3
4
(INSTALLER SUPPLIED)
OR GR
FUSE
UFH MOTORISED VALVE
6
OUT
IN
FUSE
5
- - - - - - - - THERMOSTAT NEUTRAL CONNECTIONS
9
L
N L
N
ZONE 1
OPTIONAL
CYLINDER STAT
L
N L
N
ZONE 2
L
N L
N
ZONE 3
L
N L
N
ZONE 4
+ + + + + + + + +
THERMOSTAT LIVE CONNECTIONS
L
N L
N
ZONE 5
L
N L
N
ZONE 6
L
N L
N
ZONE 7
L
N L
N
ZONE 8
Meets the following EC Directives
• Electro-Magntic Compatibility directive 2004 / 108 / EC
• Low voltage Directive 2006/95/EC
1.5MM 2 CABLE (INSTALLER SUPPLIED)
These instructions are applicable to the SALUS model
stated above.
1.5MM 2 CABLE
(INSTALLER SUPPLIED)
SUPPLIED CABLES
Warning
2
Optional wireless
receiver RX10RF
OPTIONAL UFH ZONE VALVE
FOR RADIATORS GROUPS
This product must be fitted by a competent person, and
installation must comply with the guidance, standards and
regulations applicable to the city, country or state where the
product is installed. Failure to comply with the requirements
of the relevant guidance, standards and regulations could lead
to injury, death or prosecution.
13 AMP FUSED CONNECTION UNIT
FUSED AT 3 AMPS
Warning
UNDERFLOOR HEATING MANIFOLD
Always isolate the AC Mains supply before installing or working
on any components that require 230 VAC 50Hz supply.
230V TO UFH PUMP
1.5MM 2 CABLE (INSTALLER SUPPLIED)
For PDF Installation guide please go to www.salus-controls.com
www.salus-controls.com Technical Helpline 00000 000000
Maintaining a policy of continued product development SALUS Controls plc reserve the right to change
specification, design and materials of products listed on this installation guide without prior notice.
Issue Date: June 2014 Document Number 00106
iT600 Wiring Centre KL10RF 004_Layout 1 05/06/2014 15:24 Page 2
KL10RF
Installation and Wiring Guide
Hot Water Connections
1
OPTONAL HOT
WATER
MOTORISED
VALVE
5
8
Thermostat Connections
OPTONAL UPH
MOTORISED
VALVE REMOVE
LINK IF USED
Optional Cylinder Thermostat: If connecting the cylinder thermostat
directly to the timer then a link needs to be fitted between IN and OUT.
Optional Hot Water Motorised Valve: Used if timed hot water is required.
Optional Overheat Thermostat: Used for connecting a pipe thermostat to
prevent over temperature water damaging sensitive floors. Remove the link
and connect the pipe thermostat so it is Normally Closed. The pipe stat will
open if overheating occurs and
the UFH pump will stop running.
Optional Boiler Enable: This Volt Free connection must come from the boiler
thermostat connection, when any zone calls for heat the Boiler enable will
close causing the boiler to run. If work is being carried out on the boiler then
power to and from the switch will
cease. (Do not connect to the boiler IN terminal by linking a 230V
feed from the wiring centre)
Optional UFH Motorised Valve: If a UFH motorised valve is
fitted then remove the link between OR and GR.
Optional Heat/Cool Changeover: This connection allows heat/cool
changeover of all thermostats using a single external switch (installer supplied).
Switch: Open-Heating Closed-Cooling
Option 1
Connect Cylinder
Thermostat to
wiring centre
IN OUT
HW CYLINDER
THERMOSTAT
BR EA N
OR GR
HW MOTORISED VALVE
230V AC
HW TIMER CONNECTION
SL N L
IN OUT
L
OVERHEAT STAT
N
E
UFH PUMP
IN OUT
BOILER ENABLE
BR EA N
OR GR
UFH MOTORISED VALVE
THERMOSTAT CONNECTIONS 230V AC
ZONE 1
SL N L
ZONE 2
SL N L
ZONE 3
SL N L
OPTONAL HOT
WATER
MOTORISED
VALVE
ZONE 4
SL N L
OPTONAL UPH
MOTORISED
VALVE REMOVE
LINK IF USED
Thermostat connections are to power the thermostats only, there
is no switched live needed as this is done with a wireless signal.
Power can therefore be supplied to the thermostat locally from
any convenient power source if connecting to the wiring centre
from the thermostat is difficult. Battery powered RF thermostats
can also be used. These can be mixed with 230v RF thermostats or
as an alternative.
Option 2
IN OUT
HW CYLINDER
THERMOSTAT
BR EA N
OR GR
IN OUT
HW MOTORISED VALVE
230V AC
HW TIMER CONNECTION
SL N L
OVERHEAT STAT
L
N
UFH PUMP
E
IN OUT
BOILER ENABLE
BR EA N
OR GR
UFH MOTORISED VALVE
6
Fuses
Coordinator
Information Display
3
Ribbon Connection
2
THERMOSTAT CONNECTIONS 230V AC
ZONE 1
SL N L
ZONE 2
SL N L
ZONE 3
SL N L
ZONE 4
SL N L
Sensor Terminals
Can be used for external AIR, Floor sensor
when configured as thermostat. Can also
be used for cylinder thermostat when
connected for HW.
When using option 2 refer to device
parameters on page xx of the manual.
9
7
Thermostat Zones
Connect Cylinder
Thermostat to RF
Thermostat for wire
free connection. A
link will be needed
between IN & OUT
as shown by arrow.
Motorised Valves, Pump, Boiler & Stat Connections
Groups
1
2
Actuator Connections
A Coordinator will be
needed with all RF
products.
Actuator connections corresponding to the thermostat connections. Up to 2
cables can be used in each connection (4 Actuators per Zone) If more, that
number needs to be connected, then an external junction box will be needed.
A maximum of xxx actuators can be connected to a zone in this manner.
After setting up the coordinator
will assign the wiring centre
number. This is because more than
1 wiring centre may be used on a
project. Pressing the network
button will illuminate the relevant
number. The example shown is for
wiring centre 1, if 1 & 2 are lit it
would be wiring centre 2.
In order for the wiring centre to be
able to control UFH and Radiators,
there is a need to turn off the UFH
pump for a zone when that zone is
to be used for radiators.
Eg. When fitting a zone for radiators
or towel rail then the Dip Switch for
that zone should be switched to OFF.
The Dip Switches for this are located
under the front lid. When the zone
switch is in the ON position the UFH
pump will run when that zone is
calling for heat along with the boiler.
When it is in the OFF position then
the UFH pump will not run but the
boiler will fire.
NETWORK
BUTTON
4
Dip Switch Set Up
Aerial Connection
This must be carefully removed
or replaced when removing or
replacing the wiring centre
cover, being careful to ensure
the correct orientation.
www.salus-controls.com Technical Helpline 00000 000000
There are three other function
switches as well.
Pump & Boiler delay: This gives a
three minute delay to allow
actuators to open before the boiler
fires.
Pump Only Delay: Delays only the
UFH pump from firing for three
minutes.
Actuator NC or NO: This refers to
Normally Open or Normally Closed.
This should be set to NC for
products.