accordance with the Contract Documents.

advertisement
SECTION 02800 – BARB WIRE FENCES
PART 1 -- GENERAL
1.1
WORK OF THIS SECTION
A. Furnish and install 3-strand barb wire fencing along Road 68 where existing fence is
removed or damaged as indicated on the Plans or as directed by the Engineer and in
accordance with the Contract Documents.
1.2
REFERENCE SPECIFICATIONS, CODES AND STANDARDS
A.
The publications listed below form a part of this specification to the extent referenced.
The publications are referred to within the text by the basic designation only.
B.
Commercial Standards
1.
2.
ASTM International (ASTM)
ASTM A90
Standard Test Method for Weight [Mass] of Coating on Iron
and Steel Articles with Zinc or Zinc-Alloy Coatings
ASTM A121
Metallic-Coated Carbon Steel Barbed Wire
ASTM A153
Zinc Coating (Hot-Dip) on Iron and Steel Hardware
ASTM A702
Steel Fence Posts and Assemblies, Hot Wrought
ASTM A780
Standard Practice for Repair of Damaged and Uncoated
Areas of Hot-Dip Galvanized Coatings
ASTM B221
Aluminum and Aluminum-Alloy Extruded Bars, Rods, Wire,
Profiles, and Tubes
ASTM F626
Fence Fittings
ASTM F1083
Pipe, Steel, Hot-Dipped Zinc-Coated (Galvanized) Welded,
for Fence Structures
Underwriters Laboratories (UL)
ANSI/UL 325
1.3
A.
Standard for Door, Drapery, Gate, Louver, and Window
Operators and Systems
QUALIFICATIONS
Manufacturer’s Qualifications: Barb wire fencing shall be products of a manufacturer
which has been successfully engaged in the production of such items for a period of at
least five years.
City of Visalia
WCP Upgrades: recycled Water Pipeline
Barb Wire Fences
02800-1
August 2013
B.
1.4
A.
Installer’s Qualifications: Installation of the barb wire fences shall be by the manufacturer
or by a licensed contractor registered with the manufacturer.
SUBMITTALS
General: Furnish submittals in accordance with Section 01300 - Contractor Submittals.
PART 2 -- PRODUCTS
2.1
FENCE MATERIALS
A.
Wire – Each line wire shall consist of two twisted strands of 12 ½ gauge wire or 15 ½
gauge high tensile strength wire twisted with 2 point barbs. Wire shall comply with the
requirements of ASTM A121.
B.
Steel Line Posts –
1.
Each line post shall be steel “T” type (1 3/8” x 1 3/8” x 1/8”) with a minimum weight
of 1.33 pounds per foot and shall be 5 ½ feet long with an anchor plate.
2.
Posts shall have suitable corrugations, knobs, studs, or grooves for fastening line
wires.
3.
Steel posts shall be factory painted with weather resistant paint (color from standard
color chart) or hot dipped galvanized.
4.
Setting line posts in concrete is not required.
C. Wood post will not be accepted.
D. Braces –
E.
1.
Horizontal braces shall be structural steel, 2 inch diameter.
2.
Pull posts shall be 7 feet long minimum.
Miscellaneous –
1.
Suitable galvanized devices for holding barbed wire firmly in position shall be of
commercial quality and design.
2.
Wire used to fasten barbed wire to metal posts shall be galvanized and 11 gauge or
heavier. Clips and hog rings shall be 9 gauge or heavier.
PART 3 -- EXECUTION
3.1
A.
INSPECTION
Prior to commencing installation, require Installer to inspect all areas and conditions
within which Work of this Section will be performed. Dimensions and clearances shall be
verified.
City of Visalia
WCP Upgrades: recycled Water Pipeline
Barb Wire Fences
02800-2
August 2013
3.2
A.
INSTALLATION
Clearing
1.
B.
Earth trees, brush and other obstructions which interfere with the proper
construction of fences shall be removed and disposed of unless the Engineer orders
certain trees to remain in place. This work will be considered part of the fence
construction and no measurement or payment will be made for this work.
Fence
1.
Line posts shall be equally spaced so that posts are not placed greater than 30 feet
on center. If line posts are spaced greater than 15 feet on center then stays shall be
placed equal distance between line posts.
2.
Line posts shall be placed vertical on a surveyed alignment approved by the Owner.
3.
Line posted shall be driven in place a minimum 18 inches by means that are not
damaging to the post.
4.
Wire spacing – barbed wires shall be spaced an equal distance apart and on the
private property side of the post. The top wire shall be placed 1 to 2 inches below
the top of the line post and the bottom wire shall be placed 8 to 10 inches above the
ground.
5.
Stranded wire shall be stretched between each post and fastened with suitable
fasteners at each post.
6.
Splices shall be by means of a Western Union splice or by Engineer approved splice
sleeve applied with a tool designed for the purpose.
C. Pull Assemblies
1.
Two steel posts with braces shall be spaced at intervals not to exceed 1,320 feet.
2.
Post for pull assemblies shall be spaced between 6 and 10 feet apart and drive 3
feet minimum into compacted or undisturbed soil.
3.
Horizontal braces shall be placed a minimum 3 foot above ground.
4.
Brace wire shall be double stand 9 gauge galvanized smooth wire or a double stand
of barbed wire.
D. Signs
1.
E.
All existing warning signs shall be removed from the existing fence and reinstalled
on newly installed fence.
Cleanup
1.
Remove waste fencing materials and other debris from the Site each workday.
City of Visalia
WCP Upgrades: recycled Water Pipeline
Barb Wire Fences
02800-3
August 2013
- END OF SECTION 02800 -
City of Visalia
WCP Upgrades: recycled Water Pipeline
Barb Wire Fences
02800-4
August 2013
Download