510YC25ARTG2S 500 Series - Surge Protective Device The Emerson Network Power 510 is a multi-phase, multi-mode surge protector, which incorporates the same fuse/surge array design philosophy as the 570 and 560 products. A coordinated, multi-component/multi-fuse approach is the key to addressing even the harshest conditions. With a short circuit rating of 200kAIC, a UL 1449 Type 1 rating, along with a myriad of enclosure and surge levels; the 510 can be placed on any panel within your facility, making it the ideal choice for cascaded applications. Technical Specifications Nominal Operating Voltage & Phase Configuration Operating Voltage Range Operating Frequency Range ANSI/IEEE C62.41 Category Connection Type Capacity Size Enclosure Rating Weight Modes Of Protection 277/480VAC, Three Phase Wye, 4 Wire + Gnd 50W EMI/RFI Max Attenuation SPD Monitoring Option Response Time Operating Temperature Operating Humidity Warranty Certifications Maximum Surge Current Capacity (8 x 20 ms) Line to Neutral Line to Ground Line to Line Neutral to Ground Per Phase Total 277 VAC +/- 15% 47 - 63 Hz A, B, & C Rotary Disconnect (#8 - 1/0 AWG), Neut/Gnd (#14#2) Continuous (Parallel Connection) 20" [508] x 16" [406] x 8" [203] NEMA 4, 12, 13 Steel - Indoor/Outdoor rated 56 lbs. (25.4 kgs.) L-N, L-G, L-L, N-G (All Mode) 63 db max from 10 kHz to 100MHz; The system provides up to 120dB insertion loss from 100 kHz to 100 MHz when used in a coordinated facility Advanced Transient Detection System Web-Based Power Quality Monitor * monitoring system specifications on page 2 <.5 nanoseconds - 40°C to 60°C 0% to 95% Non-Condensing 10 Years Parts UL 1449 Third Edition (2009) CUL & UL1283 250kA Per Mode / 500kA Per Phase 250kA (250,000 Amps) 250kA (250,000 Amps) 250kA (250,000 Amps) 250kA (250,000 Amps) 500kA (500,000 Amps) 1750kA (1,750,000 Amps) Features 250kA Per Mode / 500kA Per Phase Redundant Modular Design Indoor/Outdoor Rated Enclosures IEEE Life Cycle Tested Integrated Web-Based Power Quality Monitor ANSI/IEEE C62.41 Specifications Endurance/Life Cycle Testing Tested to 24,000 Impulses Per Mode without degradation Cat C3 Combination Wave UL1449 Specifications Fault Current Rating UL1449 SPD Location Type UL1449 Nominal Discharge Current (In) Maximum Continuous Operating Voltage (MCOV) L-L / L-N / L-G / N-G UL 1449 Third Edition - Voltage Protection Ratings - VPR's Line to Neutral Line to Ground Line to Line Neutral to Ground 200kAIC UL1449 Type 2 20kA 640V / 320V / 320V / 320V 1200 Vpk 1200 Vpk 2000 Vpk 1000 Vpk page 1 of 2 Line to Neutral: 1160 Vpk 1160 Vpk Line to Ground: 1800 Vpk 1360 Vpk Cat C1/B3 Combination Wave Line to Neutral: 840 Vpk 840 Vpk Line to Ground: 1500 Vpk 860 Vpk Advanced Transient Detection System Emerson Network Power Surge Protection makes it easy to monitor your electrical system by integrating its advanced Transient Detection System and monitoring package within its SPDs. The web-based device allows the end-user real time power quality measurements, logged events, statistical summaries and premium power protection. Understanding the severity, type and timing of the event allows you to analyze trends and ultimately better manage your electrical system. Technical Specifications Voltage Accuracy Range Average, Unbalance, Crest Factor Frequency Accuracy Range VTHD Range Harmonics Range RMS SPD Health Status I/O Relay Outputs RJ-45 Port Terminals (#24-#14) Events Event Logging Surge, Sag, Swell, Phase Loss/Outage, Overvoltage, Temporary Overvoltage (TOV), Voltage Interruption/Dropout, Neutral Bond, Voltage Harmonics (VTHD), Over/Under Frequency, Protection Failure Date/Time Stamp with Duration/Magnitude Surge Counter, Sag Counter, Swell Counter, w/ reset Display Communications Embedded Webpage Phase A, B, & C ± 1% 0-600V Standard Standard ± 1% 45-67 Hz Line-to-Neutral, Line-to-Line 850Hz Line-to-Neutral, Line-to-Line Fundamental – 13th ± 1% Percent Remaining Standard 1: 2 Form-C Ethernet RS-485 Communication Power Quality & System 8GB / 1000+ Events Standard Standard - All events Standard LCD 128x64 RS-485, MODBUS TCP/RTU, Ethernet, SNMP, SMTP, Form C Standard Features Power Quality – Ability to monitor voltage at every connected panel and track system anomalies such as transients, surges, swells and VTHDs. Real Time Measurements – Allows over 1000 events/reports to be stored for future analysis Event Logging – User configurable alarm thresholds, time/date stamp, duration and magnitude of events. Communications – Information easily accessed through the Ethernet or MODBUS TCP/RTU communications systems Embedded Web Page - Convenient access to present and past data right at the device. System Analysis – Manage power system with statistical summaries and reporting software. LCD Display – with capacitive touch buttons for navigation. Embedded Webpage Real-Time Monitoring of Voltages, Power Quality Events Measured and Manage Your System with User Configurable Event Counts and SPD Health Status Recorded in Detail Thresholds and Power Quality Reporting Emerson Network Power Contact information www.EmersonNetworkPower.com/Surge Surge Protection 100 Emerson Parkway Binghamton, NY 13905 T: (607) 721-8840 T: (800) 288-6169 F: (607) 722-8713 E: SurgeTech@Emerson.com Emerson Network Power, the Emerson Network Power logo and Edco are trademarks and service marks of Emerson Electric Co. ©2014 Emerson Electric Co. While every precaution has been taken to ensure accuracy and completeness herein, Emerson Network Power Surge Protection assumes no responsibility, and disclaims all liability, for damages resulting from use of this information or for any errors or omissions. Specifications are subject to change without notice. page 2 of 2 Rev. 1/15