NEXION Switchpack Heavy Duty Switchpacks Project Name: Prepared By: Project Number: Date: Catalog Number: Type: 120/277 V/AC Ballast, Tungsten, Motor Commercial Specification Grade Switchpack FEATURES • California Title 24 compliant. • Capable of switching up to 20 amps. • For use with and rated for magnetic and electronic ballasts, tungsten and motor loads. • 120 and 277V in the same unit. • Replaces separate transformers and relays. • Reduces installation expense. • Suitable for plenum installations. • Zero-crossing circuit provides increased durability, especially with today’s high inrush loads. • Can be easily mounted on or in a 4sq. junction box, via 1/2" nipple. 2.94" (75mm) 2.44" (62mm) Wire Leads Rating Description 120/277 VAC Heavy duty switchpack Catalog No. I AHSP20-MV AHSP20 Schematic TESTING & CODE COMPLIANCE MATERIAL CHARACTERISTICS • Listed to UL 508 • CSA Certified • California Title 24 Energy Code compliant • Environmental: Flammability meets UL94 requirements; V0 rated • Temperature Rating: 0ºC to 32ºC (32ºF to 104ºF) www.cooperwiringdevices.com Color Black AHSP20-MV 1.69" (43mm) Switchpack Specification & Performance Data Heavy Duty Switchpacks Project Name: Prepared By: Project Number: Date: Catalog Number: Type: 120/277 V/AC Ballast, Halogen Application Switchpacks provide 15 VDC operating voltage to all low voltage, 15 VDC, occupancy sensors and daylighting controllers. A single switchpack can provide power for up to five sensors. Up to ten switchpacks can be connected to one sensor for control of multiple circuits. Isolated contacts may also be used to control HVAC, contactors, motors, etc. The switchpack is designed to work with low voltage sensors which require switchpacks. It cannot be used with sensors designed for use with any other low voltage relay systems. Consult sensor spec sheets for other sensor/relay combinations. Device Type Heavy Duty Switchpack, AHSP20-MV Wiring Type Teflon coated wire leads Standard Configuration Wiring Diagram A/B Switching Wiring Diagram • Listed to UL 508 Testing & Code Compliance • CSA Certified Specifications: Materials Specifications: Mechanical Specifications: Electrical Specifications: Environmental • California Title 24 Energy Code compliant Warranty 5-year limited warranty Flammability Meets UL 94 requirements; V0 rated Temperature Rating 0ºC to 40ºC (32°F to 104°F) Humidity Rating Relative humidity less than 95%, non-condensing Operating Areas For indoor use only Power Requirements 120/277 VAC, 50/60 Hz Output 15 VDC 125 mA to operate up to five occupancy sensors Contacts Isolated, may be used to control low voltage circuits Ratings Tungsten: 15A, 120V Ballast : 20A, 120 or 277V Motor: 1 HP @ 120-240VAC, 2HP @ 250VAC Mounting In a 4sq. NEMA junction box or via 1/2" in nipple; plenum rated for external junction box mounting Control Connecting the 22 AWG red and blue control leads to each other will close the relay contacts Housing Medium impact-resistant injection molded ABS resin housing 1 Circuit, 2 or More Sensors Wiring Diagram 2 Circuits, 1 Sensors Wiring Diagram 3-Way Switching Wiring Diagram NOTE: The life of some compact fluorescent lamps (CFLs) is shortened by frequent automatic or manual switching. Check with the CFL and ballast manufacturer to determine effects of cycling. Specifications subject to change without notice. www.cooperwiringdevices.com 2-CLCSPSPSH-0211