ANALOGUE INSTRUMENTS ANALOGUE INSTRUMENTS nalogue Analogue instruments ANALOGUE INSTRUMENTS Analogue instruments CONTENTS GENERAL FEATURES ...................................................................................................................................................................................................................................................... AI-04 FOR ALTERNATING CURRENT INSTRUMENTS AMMETERS (INTERCHANGEABLE SCALE); DIRECT INPUT AMMETERS ...................................................................................... AI-05 AMMETERS (mA) .......................................................................................................................................................................................................................................................... AI-06 VOLTMETERS (INTERCHANGEABLE SCALE); DIRECT INPUT VOLTMETERS ....................................................................... AI-06 DIMENSIONS AND CONNECTION DIAGRAMS ..................................................................................................................................................................... AI-07 AMMETERS WITH SWITCH (INTERCHANGEABLE SCALE) ............................................................................................................................... AI-08 VOLTMETERS WITH SWITCH ..................................................................................................................................................................................................................... AI-08 DIMENSIONS AND CONNECTION DIAGRAMS ..................................................................................................................................................................... AI-09 MOVING COIL WITH CONVERTER AMMETERS AND VOLTMETERS (240º SCALE) ................................................................................................................................................................... AI-10 DIMENSIONS AND CONNECTION DIAGRAMS ......................................................................................................................................................................... AI-1 MOVING COIL WITH RECTIFIER AMMETERS AND VOLTMETERS (90º SCALE) ....................................................................................................................................................................... AI-12 AMMETERS AND VOLTMETERS (240º SCALE) ................................................................................................................................................................... AI-12 DIMENSIONS AND CONNECTION DIAGRAMS ..................................................................................................................................................................... AI-13 VRATED VALUE VOLTMETERS ......................................................................................................................................................................................................................... AI-14 ELAPSED TIME METER .................................................................................................................................................................................................................................................. AI-15 PHASE SEQUENCE INDICATORS ................................................................................................................................................................................................................. AI-15 INSTRUMENTS WITH CONTACTS ................................................................................................................................................................................................................. AI-16 BIMETALLIC INSTRUMENTS (POWER DEMAND METERS) .............................................................................................................................. AI-17 INSTRUMENTOS BIMETÁLICOS (MAXÍMETROS) ............................................................................................................................................................. AI-17 BIMETALLIC AMMETERS (INTERCHANGEABLE SCALE) ...................................................................................................................................... AI-17 BIMETALLIC AMMETERS WITH CONTACTS ............................................................................................................................................................................ AI-17 IBIMETALLIC INSTRUMENTS + MOVING IRON ..................................................................................................................................................................... AI-18 MAXIMUM DEMAND AMMETERS WITH MOVING IRON SYSTEM .............................................................................................................. AI-18 MAXIMUM DEMAND AMMETERS WITH MOVING IRON SYSTEM AND CONTACTS ......................................................... AI-18 DIMENSIONS AND CONNECTION DIAGRAMS (BIMETAL) ................................................................................................................................... AI-19 FOR DIRECT CURRENT INSTRUMENTS AMMETERS (INTERCHANGEABLE SCALE) ............................................................................................................................................................................ AI-20 AMMETERS (μA, mA and A) (90º SCALE) ..................................................................................................................................................................................... AI-20 DIMENSIONS AND CONNECTION DIAGRAMS (90º SCALE) .............................................................................................................................. AI-21 NON-ELECTRIC UNIT INDICATORS ........................................................................................................................................................................................................... AI-23 TEMPERATURE INDICATORS .............................................................................................................................................................................................................................. AI-24 SPECIAL INSTRUMENTS, MOBILE EQUIPMENT (RAILWAYS) ..................................................................................................................... AI-24 SHUNTS (RESISTORS) ..................................................................................................................................................................................................................................................... AI-25 REED FREQUENCY METERS .................................................................................................................................................................................................................................AI.26 POINTER FREQUENCY METERS .................................................................................................................................................................................................................... AI-27 DIMENSIONS AND CONNECTION DIAGRAMS AI-02 ....................................................................................................................................................................... AI-28 ANALOGUE INSTRUMENTS Analogue instruments CONTENTS WATTMETERS AND VARMETERS nalogue ELECTRONIC WATTMETERS ..................................................................................................................................................................................................................... AI-29 ELECTRONIC VARMETERS ........................................................................................................................................................................................................................... AI-30 DIMENSIONS AND CONNECTION DIAGRAMS ............................................................................................................................................................ AI-31-32 WATTMETERS AND VARMETERS (INDUCTION SYSTEMS) .............................................................................................................................. AI-33 DIMENSIONS AND CONNECTION DIAGRAMS ..................................................................................................................................................................... AI-33 PHASE METERS ELECTRONIC PHASE METERS ................................................................................................................................................................................................................ AI-34 DIMENSIONS AND CONNECTION DIAGRAMS ..................................................................................................................................................................... AI-35 PHASE METERS (INDUCTION SYSTEM) ..................................................................................................................................................................................... AI-36 DIMENSIONS AND CONNECTION DIAGRAMS ............................................................................................................................................................ AI-36-37 RESISTOR BOXES ................................................................................................................................................................................................................................................................... AI-38 SYNCHRONIZING INSTRUMENTS RELAYS EQUIPMENT FOR VESSELS MEASURING INSTRUMENTS FOR VESSELS (RECOMMENDATIONS).................................................................................... AI-40-41 FOR SYNCHRONIZING INSTRUMENTS DOUBLE VOLTMETERS ...................................................................................................................................................................................................................................... AI-42 DIFFERENTIAL VOLTMETERS ................................................................................................................................................................................................................... AI-42 DIMENSIONS AND CONNECTION DIAGRAMS ..................................................................................................................................................................... AI-42 DOUBLE FREQUENCY METERS (REEDS) ................................................................................................................................................................................ AI-43 DIFFERENTIAL FREQUENCY METERS ......................................................................................................................................................................................... AI-43 DIMENSIONS AND CONNECTION DIAGRAMS ..................................................................................................................................................................... AI-43 SYNCHRONOSCOPES ......................................................................................................................................................................................................................................... AI-44 CONNECTION DIAGRAM ................................................................................................................................................................................................................................... AI-45 LAMP SYNCHRONOSCOPE .......................................................................................................................................................................................................................... AI-46 SYNCHRONOSCOPE / DIGITAL SYNCHRONIZING RELAY ................................................................................................................................... AI-47 SYNCHRONIZING EQUIPMENT ......................................................................................................................................................................................................................... AI-48 REVERSE POWER RELAY ......................................................................................................................................................................................................................................... AI-49 SYNCHRONISING RELAY ............................................................................................................................................................................................................................................ AI-50 MAXIMUM CURRENT RELAY ................................................................................................................................................................................................................................. AI-51 MIN-MAX VOLTAGE AND FREQUENCY RELAY ..................................................................................................................................................................... AI-52 SEQUENCE METER / SEQUENCE RELAY WITH ALARM ....................................................................................................................................... AI-46 INSULATION INDICATORS ......................................................................................................................................................................................................................................... AI-53 RUDDER DEGREE INDICATORS FOR VESSELS ................................................................................................................................................................. AI-54 R.P.M. INDICATORS FOR VESSELS ........................................................................................................................................................................................................... AI-54 VOLTAGE AND CURRENT SURVEILLANCE RELAY......................................................................................................................................................... AI-55 NAVAL SURVEILLANCE RELAY ......................................................................................................................................................................................................................... AI-56 CURRENT OR POWER RELAY.............................................................................................................................................................................................................................. AI-60 AI-03 ANALOGUE INSTRUMENTS Analogue instruments GENERAL FEATURES Standards EN60051, VDE 0410, BS-89, EN50081, EN50082, EN61010 Certiications ISO 9001-2008 DET NORSKE VERITAS, BUREAU VERITAS GERMANISCHER LLOYD (relay) DIN 43700 72x72, 96x96, 144x144, 80x64, 105x80, 130x100 MODULAR (for DIN rail) Casings Scales Full scale value, DIN 43701 Scale division, DIN 43802 Pointers DIN 43802 Mounting position a 1 2 3 a 4 Overloads 1.2 Vn continuous, 2 Vn 5 s 1.5 In continuous, 5 In 30 s, 10 In 5 s, 40 In 1 s Vibration resistance VDE 0410, Section 27: 2.5 g, ±0.25 mm, 50 Hz Shock resistance VDE 0410, Section 28: 15 g Operating temperature -25ºC..+40ºC Reference temperature +10ºC..+30ºC (for accuracy class) Test voltage 2kV, 50 Hz, 1 min. Tropicalization DIN 40040 (on request) Protection IP52, IP54 (on request) casings IP00, IP20 (on request) terminals AI-04 Analogue ANALOGUE INSTRUMENTS Analogue instruments MOVING IRON Voltage and alternating current. True efective value. - Measuring range: 5A, 1A - Scale: 90º - Frequency: 15..100 Hz - Accuracy: 1.5 % - Burden: 0.4 VA Model nalogue AMMETERS (INTERCHANGEABLE SCALE) EC5VR EC5V EC4V EC3V EC4VP* EC3VP* Dimensions mm 45x52,5 DIN RAIL 48x48 72x72 96x96 72x72 96x96 Approx.weight Kg. 0,25 0,09 0,20 0,25 0,20 0,25 CT OPERATED AMMETERS (INTERCHANGEABLE SCALE) Module Scales X/5A or X/1A In 10; 15; 20; 25; 30; 40; 50; 60 or 75 A and multiples Module Scales 2X/5A or 2X/1A 2xIn 10..20; 15..30; 20..40; 25..50; 30..60; 40..80; 50..100; 60..120 or 75..150 A and multiples Module Scales 5X/5A or 5X/1A 5xIn 10..50; 15..75; 20..100; 25..125; 30..150; 40..200; 50..250; 60..300 or 75..375 A and multiples * IP20 protection DIRECT INPUT AMMETERS - Scale: 90º - Accuracy: 1,5 % - Frequency: 15..100 Hz - Burden: 0,3..1 VA Model EC5VR* EC5V* EC4V EC3V EC2V ECb7** ECb3** ECb8** Dimensions mm 45x52,5 DIN RAIL 48x48 72x72 96x96 144x144 80x64 105x80 130x100 Approx.weight Kg. 0,20 0,09 0,20 0,25 0,50 0,14 0,18 0,25 MEASURING RANGE A DIRECT INPUT AMMETERS In 1; 1,5; 2,5; 4; 5; 6; 10; 15; 20; 25; 30; 40; 50; 60; 75 or 100 A 2xIn 5xIn 1..2; 1,5..3; 2,5..5; 4..8; 5..10; 6..12 10..20; 15..30; 20..40; 25..50; 30..60; 40..80; 50..100; 60..120; 75..150 or 100..200 A 1..5; 1,5..7,5; 2,5..7,5; 4..20; 5..25; 6..30 10..50; 15..75; 20..100; 25..125; 30..150; 40..200; 50..250; 60..300; 75..375 or 100..500 A * Maximum measuring range: 40 A, 40..80 A, 40..200 A ** Maximum measuring range: 50 A, 50..100 A, 50..250 A AI-05 ANALOGUE INSTRUMENTS Analogue instruments AMMETERS (mA) - Scale: 90º - Accuracy: 1,5 % - Frequency: 15..100 Hz - Burden: 0,3..1 VA Model Dimensions mm EC5VR 45x52,5 DIN RAIL 48x48 72x72 96x96 144x144 80x64 105x80 130x100 Approx.weight Kg. 0,20 0,09 0,20 0,25 0,50 0,14 0,18 0,25 MEASURING RANGE EC5V EC4V EC3V EC2V ECb7 ECb3 ECb8 mA AMMETERS (mA) In 100; 150; 250; 300; 400; 500 or 600 mA 100..200; 150..300; 250..500; 300..600; 400..800; 500..1000 or 600..1200 mA 100..500; 150..750; 250..1250; 300..1500; 400..2000; 500..2500 or 600..3000 mA VOLTMETERS (INTERCHANGEABLE SCALE) - Measuring range: 100V, 110V - Scale: 90º - Frequency: 45..65 Hz - Accuracy: 1,5 % - Burden: 1,5..3 VA Model Dimensions Approx.weight EC5VR mm Kg. EC5V 48x48 0,09 0,20 EC3V 96x96 0,25 V CT OPERATED VOLTMETERS (INTERCHANGEABLE SCALE) Vn X/100 V or X/110 v ** 10; 12; 15; 20; 25; 30; 40; 50; 60; 75 or 80 V and multiples Module Scales EC4V 72x72 0,20 ** Standard ratings 1,2 x/100 or 1,2 x/110 V DIRECT INPUT VOLTMETERS - Scale: 90º - Accuracy: 1,5 % Model Dimensions Approx.weight MEASURING RANGE - Frequency: 45..65 Hz - Burden: 1,5..3 VA EC5VR 45x52,5 mm DIN RAIL Kg. 0,20 EC5V EC4V EC3V 48x48 72x72 96x96 144x144 0,09 0,20 0,25 EC2V 0,50 ECb7 ECb3 ECb8 80x64 105x80 130x100 72x72 96x96 0,14 0,18 0,25 0,20 0,25 V DIRECT INPUT VOLTMETERS Vn 6; 10; 15; 25; 40; 60; 100; 150; 300; 400; 500 or 600 V EC4VP* EC3VP* 300 or 500 V * IP20 protection AI-06 Analogue ANALOGUE INSTRUMENTS Analogue instruments a 28,5 Ø 35,5 b c e 7 Ø 4,3 d Models Ranges a b c d e EC5VR A - mA - V 52,5 45 75 60 38 Dimensions nalogue Dimensions ø M.6 ø b c a e d Models Ranges Remainder Remainder Remainder Remainder Dimensions c ø b g i ECb7 Ranges >15..50 A Remainder >15..<50 A ECb3 Remainder ECb8 Remainder >15..<50 A a d f Models a1 e h axa1 b c 80x64 57,6 58,6+0,6 105x80 66 67+0,7 130x100 66 67+0,8 d 63 55 63 55 63 55 e f g h i 57 63 12,5 1,5 M.3 75 81 13 4,5 M.3 100 100 13 13 M.4 Conection diagrams L1 N (L2) k l K L u R O (S) Current U L1 N (L2) v V ø M.6 M.4 M.6 M.4 M.6 M.4 R O(S) Voltage AI-07 ANALOGUE INSTRUMENTS Analogue instruments AMMETERS WITH SWITCH (INTERCHANGEABLE SCALE) 4-POSITION SWITCH (0, L1, L2, L3) - Measuring range: 5A, 1A - Scale: 90º - Frequency: 15..100 Hz - Accuracy: 1,5 % - Burden: 0,4 VA EC4V4 EC3V4 Dimensions Model mm 72x72 96x96 Approx. weight Kg. 0,25 0,50 A AMMETERS WITH SWITCH (INTERCHANGEABLE SCALE) Module Scales X/5A or X/1A 10; 15; 20; 25; 30; 40; 50; 60 or 75 A In and multiples Module Scales 2X/5A or 2X/1A 10..20; 15..30; 20..40; 25..50; 30..60; 40..80; 50..100; 60..120 or 75..150 A 2xIn and multiples Module Scales 5X/5A or 5X/1A 5xIn 10..50; 15..75; 20..100; 25..125; 30..150; 40..200; 50..250; 60..300 or 75..375 A and multiples VOLTMETERS WITH SWITCH 3-POSITION SWITCH (L1, L2, L3) 6-POSITION SWITCH (L1, L2, L3, L12, L13, L23) - Scale: 90º - Accuracy: 1,5 % Model Dimensions Approx.weight - Frequency: 45..5 Hz - Burden: 1,5..3 VA mm Kg. EC5VR 72x72 0,25 Switch 3 positions EC4V 72x72 0,25 EC3V 96x96 0,50 6 positions EC4V7* 72x72 0,25 CT OPERATED VOLTMETERS Vn X/100 V or X/110 V ** 10; 12; 15; 20; 25; 30; 40; 50; 60; 75 or 80 V and multiples CT OPERATED VOLTMETERS 500 V Scales EC3V7* 96x96 0,50 6 positions + sequence meter V Module Measuring range EC5V 96x96 0,50 * EC4V7; EC3V7: with phase sequence indicator ** Standard ratings 1,2 x/100 or 1,2 x/110 V AI-08 Analogue ANALOGUE INSTRUMENTS Analogue instruments ø e b a c 17 d Models Ranges Conection diagrams (L1) (L2) (L3) R S T R S T 0 k l k l K L k K L K Current (N) 0 l L (L1) (L2) (L3) R S T (N) 0 L1 R L1 L2 S L2 L3 T L3 N Mp N Voltage nalogue Dimensions AI-09 ANALOGUE INSTRUMENTS Analogue instruments MOVING COIL WITH CONVERTER Voltage and current measuring on alternating current circuits. AMMETERS VOLTMETERS - Scale: 240º - Accuracy: 1,5 % - Frequency: 20..100 Hz - Burden: 2,5 VA EC5CE* EC4CE EC3CE EC2CE Dimensions Model mm 48x48 72x72 96x96 144x144 Approx. weight Kg. 0,84 0,84 0,87 1,55 CT OPERATED AMMETERS Measuring range Scales X/5A or X/1A In 10; 15; 20; 25; 30; 40; 50; 60 or 75 A and multiples Measuring range Scales 2X/5A or 2X/1A 2xIn 10..20; 15..30; 20..40; 25..50; 30..60; 40..80; 50..100; 60..120 or 75..150 A and multiples Measuring range Scales 5X/5A or 5X/1A 5xIn 10..50; 15..75; 20..100; 25..125; 30..150; 40..200; 50..250; 60..300 or 75..375 A and multiples DIRECT INPUT AMMETERS Measuring range In 1; 1,5; 2,5; 4; 5; 6 or 10 A 2xIn 1..2; 1,5..3; 2,5..5; 4..8; 5..10; 6..12 or 10..20 A 5xIn 1..5; 1,5..7,5; 2,5..12,5; 4..20; 5..25; 6..30 or 10..50 A CT OPERATED VOLTMETERS Measuring range Scales X/100V or X/110V Vn 10; 12; 15; 20; 25; 30; 40; 50; 60; 75 or 80 V and multiples DIRECT INPUT VOLTMETERS Measuring range Vn 50; 60; 100; 150; 250; 300; 400; 500 or 600 V * With additional module: MBRMS model Conection diagrams Current l k K L1 L N (L2) Conection diagrams O (S) Voltage u L1 N (L2) AI-10 R U v V R O(S) Analogue ANALOGUE INSTRUMENTS Analogue instruments Dimensions 58 48 105 45 62 93 90 25 nalogue DIN rail MBRMS additional module Weight = 0,240 Plug-in connectors Dimensions ø b a c e d Models Ranges AI-11 ANALOGUE INSTRUMENTS Analogue instruments MOVING COIL WITH RECTIFIER Voltage and alternating current measuring (sinusoidal waveforms) AMMETERS (µA, mA and A) VOLTMETERS - Scale: 90º - Accuracy: 1,5 % - Frequency: 50 or 60 Hz DIN RAIL AMMETERS (µA, mA and A) VOLTMETERS - Scale: 240º - Accuracy: 1,5 % - Frequency: 50 or 60 Hz Burden Ω AI-12 Analogue ANALOGUE INSTRUMENTS Analogue instruments a 28,5 Ø 35,5 b c e 7 d Ø 4,3 Models Ranges a b c d e CC5VRG µA; mA; A; V 52,5 45 75 60 38 nalogue Dimensions ø M.6 ø Dimensions b c a e d Models Ranges c Dimensions ø g b a1 e h i a d f Models Ranges axa1 b c d e f g h i ø CCb7G µA; mA; A; V 80x64 57,6 58,6+0,6 59 57 63 12,5 1,5 M.3 M.4 59 75 81 13 4,5 M.3 M.4 59 100 100 13 13 M.4 M.4 CCb3G µA; mA; A; V 105x80 66 67+0,7 CCb8G µA; mA; A; V 130x100 66 67+0,8 ø Dimensions b a c e d Models Ranges Remainder Conection diagrams u L1 N (L2) Current k l K L R O (S) L1 N (L2) U Voltage v V R O(S) AI-13 ANALOGUE INSTRUMENTS Analogue instruments RATED VALUE VOLTMETERS - Scale: 90º - Accuracy: 1,5 % - Frequency: 50 or 60 Hz - Burden: 2 mA Model CC4VGN CC3VGN CC2VGN Dimensions mm 72x72 96x96 144x144 Approx. weight Kg. 0,17 0,25 0,48 VOLTMETERS Measuring range Vn 100; 110; 230 or 400 V 90..110 V or ±10% X/100 V 100..120 V or ±10% X/110 V 210..250 V 380..420 V Scales Dimensions e b a c ø d Models Ranges Conection diagrams Voltage u L1 N (L2) AI-14 U v V R O(S) Analogue ANALOGUE INSTRUMENTS Analogue instruments ELAPSED TIME METER - Meter: mechanical, 7 digits (99999.99) - Voltage (Vn): 110, 230, 400 V - Burden: 10 mA - Voltage range: ±10 % Vn - Frequency: 50 or 60 Hz Model nalogue Operating time control of machines and equipment. HC5 HC4 HC3 Dimensions mm 48x48 72x72 96x96 Approx. weight Kg. 0,06 0,14 0,175 Dimensions L1 N (L2) d Models Conection diagrams b a c ø R O(S) Ranges u v U L1 N (L2) V PHASE SEQUENCE INDICATORS Phase sequence detection on a three-phase system. - Voltage: (Vn): 100..600 V - Frequency: 50 or 60 Hz - Burden: 1,2 VA IRC4E IRC3E Dimensions Model mm 72x72 96x96 Approx. weight Kg. 0,20 0,26 Dimensions Conection diagrams b a c ø d R Models Ranges R O(S) R S L1 L2 T L3 L1 S L2 T L3 AI-15 ANALOGUE INSTRUMENTS Analogue instruments INSTRUMENTS WITH CONTACTS 2 contacts and 2 control LEDs. Rear adjustment. 2 channels. 2 potentiometers per channel. DELAY (sg.) % End scale 25 10 0 0 II MODELS ..A/1 - 1Min. and 1 Max. contact ..A/2 - 2Max. or Min contacts 50 20 75 30 10 100 25 50 0 0 I 20 Setting: 0 - 100% of full scale value or ±100% (bidirectional) Delay time: 0-30 s. ±10% Repeatability: ±1% of full scale value Output relays: 2 (Max. 400 V, 1 A, 200 VA AC.) Mechanical life: 107 operations Control unit cover: Lockable Auxiliary power supply: 110, 230, 400 V AC. Burden, 3 VA. 30 75 100 Technical speciications same as pointer instruments. - MOVING IRON (mA y A) - MOVING COIL (mV, V, µA, mA and A) - MOVING COIL WITH RECTIFIER (mV, V, mA and A) - FREQUENCY METERS (Hz) - MEASURERS FOR CONVERTERS (mA and V) - Scale: 90º - Accuracy: 1,5 % Model Contacts Dimensions Approx. weight - Frequency: 50 or 60 Hz mm Kg. ..A/1 1 Min.- and 1 Max.96x96 0,55 ..A/2 2 Max.96x96 0,55 Dimensions ø b c a e d Models Ranges Conection diagrams Input Aux. v. 4 1 2 3 7 5 6 8 9 10 With voltage on 9-10; 4-5 and 7-8 closed. With alarm, 3-4 and 6-7 closed. AI-16 Analogue ANALOGUE INSTRUMENTS Analogue instruments BIMETAL MAXIMUM DEMAND AMMETERS (INTERCHANGEABLE SCALE) - Measuring range: 5A, 1A - Scale: 90º - Frequency: 0..1000 Hz - Accuracy: 2,5 % - Burden: 2,3 VA Model Dimensions Approx. weight mm Kg. BC5VR* 45x52,5 0,20 A BC5V* 48x48 0,20 BC3V 96x96 0,31 1,2X/5A or 1,2X/1A 1,2xIn 1,2; 6; 12; 18; 24; 30; 36; 48; 60; 72, 90 A or 120% and multiples * 1.2X/5A only *** BC2V, interchangeable scale not available MAXIMUM DEMAND AMMETERS WITH CONTACTS BIMETALLIC SYSTEM WITH ALARM CIRCUIT - Measuring range: 5A, 1A - Scale: 90º - Frequency: 0..1000 Hz - Accuracy: 2,5 % - Burden: 2,3 VA Model BC2V*** 144x144 0,60 MAXIMUM DEMAND AMMETER (INTERCHANGEABLE SCALE) Module Scales BC4V 72x72 0,23 nalogue Maximum demand ammeters for alternating current: Effective current value averaged over 15 or 8 minutes. BC4VA BC3VA Dimensions mm 72x72 96x96 144x144 Approx. weight Kg. 0,37 0,45 0,74 MAXIMUM DEMAND AMMETERS WITH CONTACTS Measuring range Scales Vn 1,2X/5A or 1,2X/1A 1,2; 6; 12; 18; 24; 30; 36; 48; 60; 72 or 90 A 120% ALARM CIRCUIT: - Max. with contacts (red LED) - Aux. v: 100; 110; 230; 400 V (AC.) Burden: 3.75 VA (AC.) - Aux. v: 12; 24; 48 V (DC.) Burden: 66; 56; 38 mA (DC.) and multiples BC2VA - Relay output: 1 Relay (Max. 400 V, 1 A, 200 VA) - Accuracy: 2% - Hysteresis: ≤1% - Adjustable from the front AI-17 ANALOGUE INSTRUMENTS Analogue instruments BIMETAL + MOVING IRON MAXIMUM DEMAND AMMETERS (bimetallic system) with moving iron system. DOUBLE AMMETERS (INTERCHANGEABLE SCALE) - Measuring range: 5A, 1A - Frequency: 15..100 Hz - Scale: 90º - Burden: 2,7 VA - Accuracy: 2,5 % (bimetallic syst.) / 1,5% (moving iron system) Model BEC4V BEC3V BEC2V** Dimensions mm 72x72 96x96 144x144 Approx. weight Kg. 0,23 0,31 0,60 DOUBLE AMMETERS (INTERCHANGEABLE SCALE) Module Bimetal 1,2xIn 1,2X/5A or 1,2X/1A Moving iron 2xIn 2X/5A or 2X/1A Escales Bimetal 1,2xIn 1,2; 6; 12; 18; 24; 30; 36; 48; 60; 72, 90 A or 120% Moving iron 1,2xIn 1..2; 5..10; 10..20; 15..30; 20..40; 25..50; 30..60; 40..80; 50..100; 60..120 or 75..150 A and multiples ** BC2V, interchangeable scale not available DOUBLE AMMETERS WITH CONTACTS BIMETALLIC SYSTEM WITH ALARM CIRCUIT - Measuring range: 5A, 1A - Frequency: 15..100 Hz - Scale: 90º - Burden: 2,7 VA - Accuracy: 2,5 % (bimetallic syst.) / 1,5% (moving iron system) Model BEC4VA BEC3VA BEC2VA Dimensions mm 72x72 96x96 144x144 Approx. weight Kg. 0,40 0,50 0,88 DOUBLE AMMETERS (INTERCHANGEABLE SCALE) Module Bimetal 1,2xIn 1,2X/5A or 1,2X/1A Moving iron 2xIn 2X/5A or 2X/1A Escales Bimetal 1,2xIn 1,2; 6; 12; 18; 24; 30; 36; 48; 60; 72, 90 A or 120% Moving iron 1,2xIn 1..2; 5..10; 10..20; 15..30; 20..40; 25..50; 30..60; 40..80; 50..100; 60..120 or 75..150 A and multiples ALARM CIRCUIT: - Max. with contacts (red LED) - Aux. v: 100; 110; 230; 400 V (AC.) Burden: 3.75 VA (AC.) - Aux. v: 12; 24; 48 V (DC.) Burden: 66; 56; 38 mA (DC.) AI-18 - Relay output: 1 Relay (Max. 400 V, 1 A, 200 VA) - Accuracy: 2% - Hysteresis: ≤1% - Adjustable from the front Analogue ANALOGUE INSTRUMENTS Analogue instruments a b c e Ø 7 35,5 28,5 d Ø 4,3 Models Ranges a b c d e BC5VR /5 A 52,5 45 75 60 38 Dimensions ø M.6 e b a c ø d Models Ranges ø e b a c Dimensions f d Models Ranges Conection diagrams 7 2 k L1 N (L2) 6 4 1 3 l Aux. V K 5 L nalogue Dimensions k l K L R O (S) Maximum demand and double ammeters with contacts Maximum demand and double ammeters AI-19 ANALOGUE INSTRUMENTS Analogue instruments MOVING COIL Voltage and current measuring on direct current circuits. AMMETERS (INTERCHANGEABLE SCALE) Via resistors (Shunt) - Scale: 90º - Accuracy: 1,5 % - Measuring range: 60 mV, 150 mV - Burden: 60 - 150 Ω Model CC5VR CC5V CC4V CC3V CC4VP* CC3VP* Dimensions mm 45x52,5 DIN RAIL 48x48 72x72 96x96 72x72 96x96 Approx.weight Kg. 0,10 0,09 0,21 0,28 0,21 0,28 AMMETERS (INTERCHANGEABLE SCALE) Module Vn X/60 mV or X/150 mV In 1; 1,5; 2,5; 4; 5; 6; 10; 15; 20; 30; 40; 50; 60; 80 or 100 A and multiples IP20 protecction AMMETERS (µA, mA y A) VOLTMETERS (mV, y V) - Scale: 90º - Accuracy: 1,5 % Model CC5VR* CC5V* CC4V CC3V CC2V CCb7** CCb3** CCb8** DIN RAIL 48x48 72x72 96x96 144x144 80x64 105x80 130x100 0,10 0,09 0,21 0,28 0,50 0,15 0,19 0,25 Dimensions mm 45x52,5 Approx.weight Kg. AMMETERS (µA) 40; 50; 60; 100; 250; 300; 400; 500 or 600 µA MEASURING RANGE In AMMETERS (mA) 1; 1,5; 2,5; 4; 5; 6; 10; 15; 20; 25; 40; 50; 60; 100; 150; 250; 300; 400; 500 or 600 mA 4-20 mA AMMETERS (A) 1; 1,5; 2,5; 4; 5; 6; 10; 15; 20; 25; 40 or 50 A VOLTMETERS (mV) Vn 10; 15; 20; 25; 40; 60; 100; 150; 250; 300; 400; 500 or 600 mV VOLTMETERS (V) 1; 1,5; 2,5; 4; 5; 6; 10; 15; 20; 25; 40; 50; 60; 100; 150; 250; 300; 400; 500 or 600 V * Maximum measuring 40 A ** >600-<1000 V, resistor boxe 1.2.1. (pag 38) / 1000-2000 V, resistor boxe - 3.3.1 / >2000-4000 V, resistor boxe -3.3.2 (pag 38) Internal resistor (Ω) / Burden Range 60 mV approx. 1000 Ω / V approx. AI-20 Analogue ANALOGUE INSTRUMENTS Analogue instruments 28,5 7 35,5 b c e Ø Models 6 a d Ø 4,3 Ranges Dimensions ø b c a e d Models Ranges □a □b □c d e CC5V x/60..x/150 mV 48 44,5 45+0,6 59 38 CC4V x/60..x/150 mV 72 66,5 68+0,7 60 65 CC3V x/60..x/150 mV 96 89 92+0,8 59 100 >4..15 A 63 >15..50 A CC5V 48 44,5 45+0,6 >4..15 A 66,5 68+0,7 60 >4..15 A 63 96 89 92+0,8 59 >4..15 A 63 CC2V >15..50 A CC4VP CC3VP 65 x/60..x/150 mV 72 66,5 68+0,7 68 140 58 65 x/60..x/150 mV 96 90 92+0,8 58 100 59 b g Models Ranges CCb7 >15..50 A Remainder <4...15A >15..<50 A Remainder <4...15A >15..<50 A Remainder CCb3 CCb8 a1 e i a d f axa1 b c d <4...15A 80x64 57,6 58,6+0,6 63 105x80 66 67+0,7 63 130x100 66 67+0,8 63 55 Conection diagrams + e 59 57 55 59 75 55 59 100 + f g h 63 12,5 81 100 M.4 M.4 i ø 1,5 M.3 M.4 M.6 M.4 13 4,5 M.3 M.6 M.4 13 13 M.4 M.6 M.4 + Current M.6 M.4 ø h M.6 M.4 138+1 c M.6 M.4 135 Dimensions M.6 M.4 100 144 Remainder M.4 M.4 68 Remainder M.4 M.4 68 Remainder M.4 M.4 63 72 >15..50 A CC3V 38 59 >15..50 A CC4V ø M.4 62 Remainder nalogue Dimensions Voltage + + + - - - AI-21 ANALOGUE INSTRUMENTS Analogue instruments AMMETERS (µA, mA y A) VOLTMETERS (mV, y V) - Scale: 240º - Accuracy: 1,5 % Model Dimensions Approx.weight mm Kg. CC5C 48x48 0,20 CC4C 72x72 0,32 CC3C 96x96 0,38 CC2C 144x144 0,68 AMMETERS (μA, mA y A) - VOLTMETERS (mV and V) MEASURING RANGE In Vn 150; 250; 300; 400; 500 or 600 μA 1; 1,5; 2,5; 4; 5; 6; 10; 15; 20; 25; 40; 50; 60; 100; 150; 250; 300; 400; 500 or 600 mA 4-20 mA 1; 1,5; 2,5; 4; 5; 6; 10 or 15 A 60; 100; 150; 250; 300; 400; 500 or 600 mV 1; 1,5; 2,5; 4; 5; 6; 10; 15; 20; 25; 40; 50; 60; 100; 150; 250; 300; 400; 500 or 600 V Internal resistor (Ω) / Burden Range 150 mV approx. 1000 Ω / V approx. Dimensions ø b a c e d Models Ranges Remainder Remainder Remainder Remainder Conection diagrams + + + + - - - Current AI-22 + + Voltage Analogue ANALOGUE INSTRUMENTS Analogue instruments NON-ELECTRIC UNIT INDICATORS Parameter measurements from transducers or converters, calibrated according to their function curves. - Scale: 90 or 240º - Accuracy: 1,5 % CC5V CC4V Dimensions Model mm 48x48 72x72 Approx. weight Kg. 0,10 0,21 CC3V 96x96 0,28 VOLTMETERS MEASURING RANGE Vn 0-1; 0-5 or 0-10 V 1-5 or 2-10 V MILLIAMMETERS 0-1; 0-5; 0-10 or 0-20 mA Model 4-20 mA CC5C CC4C Dimensions mm 48x48 72x72 Approx. weight Kg. 0,20 CC3C 96x96 0,32 0,38 VOLTMETERS MEASURING RANGE Vn 0-1; 0-5 or 0-10 V 1-5 or 2-10 V MILLIAMMETERS 0-1; 0-5; 0-10 or 0-20 mA 4-20 mA May be manufactured in several models and direct current ranges with or without suppressed zero. Other features as corresponding models. Dimensions Dimensions ø d d Models Ranges Conection diagrams + Ranges Examples of units + + + + + - - - Current b c a e e b a c ø Models nalogue DIRECT CURRENT φ Ω Voltage AI-23 ANALOGUE INSTRUMENTS Analogue instruments TEMPERATURE INDICATORS Temperature measuring via thermocouples or thermoresistances. - Scale: 90 - Accuracy: 1,5 % CC4V CC3V Dimensions Model mm 72x7 96x96 Approx. weight Kg. 0,20 0,26 Type TEMPERATURE INDICATORS - DIN THERMOCOUPLE T K E J (Fe-Const.) (Chr-Alu) Scales 20-400º 20-600º Ranges 20,83 32,08 20-900º 20-600º 50,86 24,10 S (Chr-Const.) (Cu-Const.) (Pt-PtRh) 20-900º 20-1200º 20-1000º 20-400º 20-1200º 20-1600º 36,53 48,03 75,16 20,08 11,83 16,66 TEMPERATURE INDICATORS - THERMORESISTANCES Type Pt-100 DIN Scales 0-100º Aux. v V NI-100 DIN 0-150º 0-100º 0-150º 12, 24, 48 or 110 V D.C 12, 24, 48 or 110 V D.C. - 110, 230 or 400 V A.C. The instrument indicates the temperature difference between the thermocouple welding point and the connection point of the two thermocouple elements with the instrument interconnection line. If, in this last connection point, the temperature is 20° higher than the instrument calibration point, then a suitable correction line in each thermocouple is necessary. The instrument is calibrated according to the thermometric resistance boards. The 2 or 3 wire connection must be speciied. Dimensions Conection diagrams ø e b +- a c + DIN thermocouple Vaux. Vaux. d Models Ranges Thermoresistances SPECIAL EXECUTIONS: MOBILE INSTRUMENTS - CR2C Moving coil Instrument for mobile equipment (railways, tractor). Measuring range and scales: please enquire. Scale: 240º Black scale Accuracy: 1.5% Aux. v: 12 or 24 V (DC.) Shock resistance: 15 g Vibration resistance: 10..55 Hz White or yellow pointer, numbering and division . Dimensions 107 4,5 67,5 35 Ø79,5 Ø 85,5 97 AI-24 Analogue ANALOGUE INSTRUMENTS Analogue instruments SHUNTS - Accuracy: 0,5% - Overloads: Operating t.: -20..+60 ºC 1.2 In continuously 10 In 5 s (10..500 A) 5 In 5 s (600..2000 A) 2 In 5 s (2500..4000 A) DIN 43703 standard Model Voltage drop Form 2 Form 1 60 mV mV MEASURING RANGE 150 mV 60 mV In Form 3 150 mV 60 mV 200; 250; 300; 400; 500; 600; 200; 250; 300; 750; 800; 1000; 400; 500; 600; 1200; 1500; 750; 800 or 1000 1; 1,5; 2,5; 4; 5; 6; 10; 15; 20; 25; 30; 40; 50; 60; 80; 100 or 150 150 mV 1200; 1500; 2000 or 2500 3000 or 4000 2000 or 2500 ) Approximate weight (Kg) In 1 60 mV 1,5 2,5 4 5 6 10 15 20 25 nalogue High value current connection on direct current circuits. 30 40 50 60 80 100 150 200 0,140 0,140 0,140 0,140 0,140 0,140 0,140 0,140 0,140 0,140 0,120 0,120 0,125 0,125 0,125 0,125 0,130 0,535 150 mV 0,140 0,140 0,140 0,140 0,140 0,140 0,140 0,140 0,140 0,140 0,160 0,170 0,175 0,180 0,190 0,210 0,240 0,750 250 300 400 500 600 750 800 - - - - - - 150 mV 0,790 1,130 1,200 1,250 1,310 2,350 2,390 2,510 3,670 3,860 5,220 5,530 - - Current splice Voltage drop mV Exec. according a1 a2 b1 b2 b3 c1 c2 to igure Rated current A M.8x16 8,4 - 100 33 20 - - 8 - 80 - 2x1 30*; 40; 50; 60; 80*; 100; 150 1 100 33 20 - - 8 - 80 - 2x1 30 15 - 300*; 400; 500*; 600 40 20 - 750*; 800*; 1000 60 30 - 2 2 145 55 165 65 10 10 105 30 10 10 115 30 90 21 48 10 30 2x1 M.16 21 M.20 2x2 M.16x45 17 M.16 21 M.20 M.8x16 8,4 - 1; 1,5; 2,5; 4; 5*; 6; 10; 15; 20*; 25 1 100 33 20 - - 8 - - 2x1 30*; 40; 50; 60; 80*; 100; 150 1 225 33 25 - - 8 - 205 - 2x1 200*; 250 2 300*; 400; 500*; 600 750*; 800* 2 1000* 2 1200*; 1500 3 2000*; 2500 3 270 55 275 30 15 - 40 20 - 85 42,5 - 230 50 10 10 240 21 43 90 21 48 15 10 240 60 290 65 120 30 60 Form 1 Form 2 a2 2x2 2x1 M.8x16 8,4 - M.12x40 13 M.12 M.16x45 17 M.16 M.20x60 M.20 2x2 M.16x45 21 17 2x2 M.16x60 M.20x60 17 21 c2 M.16 M.16 M.20 Form 3 a2 a2 140 - 2 M.5x8 cylinder-head screw DIN 84-4.8 and 2 ø 5.3 washers DIN 433-St. e a1 e a1 b2 b2 b3 b1 b3 b1 9 - - b3 122 - - Voltage splice c1 c1 h c1 11 c2 M.20x50 M.20x60 60 80 M.12 17 3 10 115 - 13 M.20x50 2 15 8,4 M.16x45 3000*; 4000 165 65 120 30 60 M.8x16 M.12x40 2x1 2000*; 2500 30 * Non-DIN ranges, but of standard production. Nut DIN 934-5 1 1200*; 1500 150 Nº. Hexagonal Washer of DIN screw screws DIN 933-5-8 125-Sc 1; 1,5; 2,5; 4; 5*; 6; 10; 15; 20*; 25 200*; 250 60 eh - h 1000 1200 1500 2000 2500 3000 4000 0,540 0,815 0,820 0,830 0,840 1,420 1,420 1,440 1,970 1,990 2,870 2,990 4,220 4,300 b1 In 60 mV e a1 AI-25 ANALOGUE INSTRUMENTS Analogue instruments FREQUENCY METERS System frequency measuring. REED FREQUENCY METERS - Voltage range: ±15 % Vn - Voltage: (Vn): 100, 110 230, 400, 440 V Model - Accuracy: 0,5 % - Burden: 1,2..2,2 VA FC3VI, FC2VI: 2x (1,2..2,2 VA) FC5V FC4V FC3V FC2V FC3VI FC2VI Dimensions mm 48x48 72x72 96x96 144X144 96x96 144x144 Approx. weight Kg. 0,23 0,39 0,47 0,88 0,84 1,50 2x17 2x21 46..64 45..65 REED FREQUENCY METERS Reeds Scales Hz 7 13 13 17 21 48,5..51,5 47..53 47..53 46..54 45..55 58,5..61,5 57..63 57..63 56..64 55..65 Dimensions b a c ø d Models Ranges Conection diagrams u L1 N (L2) AI-26 U v V R O(S) Analogue ANALOGUE INSTRUMENTS Analogue instruments POINTER FREQUENCY METERS - Accuracy: 0,5 % - Burden: 10 mA 90º SCALE Model FC5AR FC5A FC4A FC3A Dimensions mm 45x52,5 DIN RAIL 48x48 72x72 96x96 Approx. weight Kg. 0,20 0,20 0,21 FC2A FC5ARI 144x144 45x52,5 DIN RAIL 0,28 0,50 FC5AI FC4AI FC3AI FC2AI 48x48 72x72 96x96 144x144 0,20 0,21 0,28 0,50 0,20 POINTER FREQUENCY METERS 90º Reeds Hz 45..55; 48..52; 55..65; 58..62 or 380..420 Hz 45..65 Hz 240º SCALE Model FC5C* FC4C FC3C FC2C FC5CI* FC4CI FC3CI Dimensions mm 48x48 72x72 96x96 144x144 48x48 72x72 96x96 Approx. weight Kg. 0,25 0,46 0,55 1,05 0,25 0,46 0,55 POINTER FREQUENCY METERS 240º Reeds Hz 45..55; 48..52; 55..65; 58..62 or 380..420 Hz 45..65 Hz * With additional module: MBF model Dimensions DIN rail MBF module 58 48 52,5 93 45 62 25 90 nalogue - Voltage range: ±15 % Vn - Voltage: (Vn): 100, 110 230, 400, 440 V FC2CI 144x144 1,05 Weight = 0,120 Plug-in connectors Dimensions e Ø 7 35,5 28,5 b c a d Ø 4,3 Models Ranges a b c d e FC5AR 100÷230 52,5 45 75 60 38 FC5AIR 100÷230 52,5 45 75 60 38 ø M.6 M.6 AI-27 ANALOGUE INSTRUMENTS Analogue instruments Dimensions e b a c ø d Models Ranges Dimensions ø b a c e d Models Ranges Conection diagrams u L1 N (L2) AI-28 U v V R O(S) Analogue ANALOGUE INSTRUMENTS Analogue instruments WATTMETERS (ELECTRONIC) System active power measuring. - Frequency: 50 or 60 Hz - Voltage range: ±15 % Vn - Voltage: (Vn): 100, 110 230, 400, 440 V - Current range: 20-120% - Current input: (In): 5A, 1A - Accuracy: 1,5 % - Burden: 3..12 mA (Voltage circuits) - Burden: 1..3,5 VA (Current circuits) 90º SCALE Dimensions 45x52,5 mm 48x48 CARRIL DIN 72x72 96x96 144x144 AC. SINGLE-PHASE - BALANCED THREE-PHASE Approx. weight Kg. 0,55 0,55 0,55 0,84 AC. Single-phas WC5VRE* WC5VE* WC4VE* WC3VE Three-phase, 3 or 4 wire WC5VRIE* WC5VIE* WC4VIE* WC3VIE 1,00 1,00 1,00 1,55 Three-phase, 3 wire WC5VRIIE* WC5VIIE* WC4VIIE* WC3VIIE Three-phase, 4 wire WC5VR3E* WC5V3E* WC4V3E* WC3V3E 0,84 WC2VE WC2VIE UNBALANCED THREE-PHASE Approx. weight Kg. 1,55 WC2VIIE WC2V3E 240º SCALE Dimensions mm 48x48 Approx. weight Kg. 0,55 72x72 96x96 144x144 AC. SINGLE-PHASE - BALANCED THREE-PHASE 0,55 0,84 0,84 AC. Single-phas WC5CE* WC4CE* WC3CE Three-phase, 3 or 4 wire WC5CIE* WC4CIE* WC3CIE WC2CE WC2CIE UNBALANCED THREE-PHASE Approx. weight Kg. 1,00 1,00 1,55 Three-phase, 3 wire WC5CIIE* WC4CIIE* WC3CIIE Three-phase, 4 wire WC5C3E* WC4C3E* WC3C3E 1,55 WC2CIIE WC2C3E * With additional module: MBW.. Models INTERCHANGEABLE SCALE (90° scale only), for models: WC5V..., WC5VR..., WC4V... and WC3V... For 3 or 4 wire, balanced or unbalanced three-phase systems, the instruments and scales are: Instruments 110 V, 5 A 230 V, 5 A 400 V, 5 A 440 V, 5 A Instruments 110 V, 5 A 230 V, 5 A 400 V, 5 A Calibration 1000 W 2000 W 3000 W 3000 W Calibration 1000 W 2000 W 3000 W 10/5 A 0-2 kW 0-4 kW 0-6 kW 0-6 kW 40/5 A 0-8 kW 0-15 kW 0-24 kW 15/5 A 0-3 kW 0-6 kW 0-9 kW 0-9 kW 50/5 A 0-10 kW 0-20 kW 0-30 kW 20/5 A 0-4 kW 0-8 kW 0-12 kW 0-12 kW 60/5 A 0-12 kW 0-24 kW 0-36 kW 25/5 A 0-5 kW 0-10 kW 0-15 kW 0-15 kW 75/5 A 0-15 kW 0-30 kW 0-45 kW 30/5 A 0-6 kW 0-12 kW 0-18 kW 0-18 kW Multiples Multiples Multiples Multiples Transformator Transformator Scales nalogue Alternating current Scales 440 V, 5 A 3000 W 0-24 kW 0-30 kW 0-36 kW 0-45 kW Multiples Dimensions and connection diagrams, available on page AI-31-32. AI-29 ANALOGUE INSTRUMENTS Analogue instruments VARMETERS (ELECTRONIC) System's reactive power measuring. Alternating current - Frequency: 50 or 60 Hz - Voltage range: ±15 % Vn - Voltage: (Vn): 100, 110 230, 400, 440 V - Current range: 20-120% - Current input: (In): 5A, 1A - Accuracy: 1,5 % - Burden: 3..12 mA (Voltage circuits) - Burden: 1..3,5 VA (Current circuits) 90º SCALE Dimensions mm 45x52,5 Approx. weight Kg. 0,55 0,55 0,55 0,84 0,84 AC. Single-phas WC5VRrE* WC5VrE* WC4VrE* WC3VrE WC2VrE Three-phase, 3 or 4 wire WC5VRIrE* WC5VIrE* WC4VIrE* WC3VIrE WC2VIrE 48x48 DIN RAIL 72x72 96x96 144x144 AC. SINGLE-PHASE - BALANCED THREE-PHASE UNBALANCED THREE-PHASE Approx. weight 1,00 1,00 1,00 1,55 1,55 Three-phase, 3 wire Kg. WC5VRIIrE* WC5VIIrE* WC4VIIrE* WC3VIIrE WC2VIIrE Three-phase, 4 wire WC5VR3rE* WC5V3rE* WC4V3rE* WC3V3rE WC2V3rE 240º SCALE Dimensions mm 48x48 96x96 72x72 144x144 AC. SINGLE-PHASE - BALANCED THREE-PHASE Approx. weight Kg. 0,55 0,55 0,84 0,84 AC. Single-phas WC5CrE* WC4CrE* WC3CrE WC2CrE Three-phase, 3 or 4 wire WC5CIrE* WC4CIrE* WC3CIrE WC2CIrE UNBALANCED THREE-PHASE Approx. weight Kg. 1,00 1,00 1,55 1,55 Three-phase, 3 wire WC5CIIrE* WC4CIIrE* WC3CIIrE WC2CIIrE Three-phase, 4 wire WC5C3rE* WC4C3rE* WC3C3rE WC2C3rE * With additional module: MBW... Models INTERCHANGEABLE SCALE (90° scale only), for models: WC5V...rE, WC5VR...rE, WC4V...rE y WC3V...rE For 3 or 4 wire, balanced or unbalanced three-phase systems, the instruments and scales are: Instruments 110 V, 5 A 230 V, 5 A 400 V, 5 A 440 V, 5 A Instruments 110 V, 5 A 230 V, 5 A 400 V, 5 A 440 V, 5 A Calibration 500 Var 1000 Var 1500 Var 1500 Var Calibration 500 Var 1000 Var 1500 Var 1500 Var Transformator Transformator Scales Scales 10/5 A 0-1 Kvar 0-2 Kvar 0-3 Kvar 0-3 Kvar 40/5 A 0-4 Kvar 0-7,5 Kvar 0-12 Kvar 0-12 Kvar 15/5 A 0-1,5 Kvar 0-3 Kvar 0-4,5 Kvar 0-4,5 Kvar 50/5 A 0-5 Kvar 0-10 Kvar 0-15 Kvar 0-15 Kvar 20/5 A 0-2 Kvar 0-4 Kvar 0-6 Kvar 0-6 Kvar 60/5 A 0-6 Kvar 0-12 Kvar 0-18 Kvar 0-18 Kvar 25/5 A 0-2,5 Kvar 0-5 Kvar 0-7,5 Kvar 0-7,5 Kvar 75/5 A 0-7,5 Kvar 0-15 Kvar 0-22,5 Kvar 0-22,5 Kvar 30/5 A 0-3 Kvar 0-6 Kvar 0-9 Kvar 0-9 Kvar Multiples Multiples Multiples Multiples Multiples Dimensions and connection diagrams, available on page AI31-AI32. AI-30 Analogue ANALOGUE INSTRUMENTS Analogue instruments Dimensions DIN rail MBW and MBWr modules nalogue 93 90 45 62 58 48 25 105 Weight = 0,240 Plug-in connectors Dimensions Ø 35,5 b e c 7 28,5 a d Ø 4,3 Active power model Reactive power model Range a b c d e WC5VR..E WC5VR..rE ../5 ../1 52,5 45 75 60 38 Dimensions e b a c ø d Active power model Reactive power model Range Dimensions ø b a c e d Active power model Reactive power model Range ø M.6 AI-31 ANALOGUE INSTRUMENTS Analogue instruments Connection diagrams Single-phase, Active and Reactive Power 1 2 3 5 2 5 1 3 k l R 0(S) K Direct input Connection: u v U V L1 N L Voltage Transf. Connection diagrams Current Transf. Balanced three-phase, Active and Reactive Power 1 2 3 5 8 2 1 3 5 8 u v u v U V U V k l R S T Connection: K Direct input L Voltage Transf. Connection diagrams L1 L2 L3 Current Transf. 4 wire balanced three-phase, Active and Reactive Power 1 2 3 5 8 2 1 3 5 8 u v u v U V U V k l R S T 0 K Direct input Connection: Voltage Transf. Connection diagrams 1 2 3 5 7 8 9 L Connection: 1 3 7 9 K L 2 Connection: 1 3 4 6 7 9 K k l AI-32 2 5 u x x u 8 u x x u L1 L2 L3 N Current Transf. Balanced three-phase, Active and Reactive Power 1 3 4 6 7 9 K 2 u x x u k l 5 u x x u 8 u x x u k l L K L K Direct input L1 L2 L3 Current Transf. L Voltage Transf. k l Connection: U V k l Connection diagrams R S T 0 U V L K 1 2 3 4 5 6 7 8 9 11 u v u x x u L K Direct input u v 3 syst. unbalanced three-phase, Active and Reactive Power k l R S T 0 8 L Voltage Transf. Connection diagrams 1 2 3 4 5 6 7 8 9 5 k l K Direct input Current Transf. 4 wire unbalanced three-phase, Active and Reactive PowerPower k l R S T L1 L2 L3 N L Voltage Transf. L1 L2 L3 N Current Transf. Analogue ANALOGUE INSTRUMENTS Analogue instruments WATTMETERS (INDUCTION) VARMETERS (INDUCTION) System active/reactive power measuring - Scale: 90º - Frequency: 50, 60 Hz - Voltage range: ±15 % Vn - Voltage: (Vn): 100, 110 230, 400, 440 V - Current input: (In): 5A, 1A - Current range: 20-120% - Accuracy: 1,5 % - Burden: 3..12 mA (Voltage circuits) - Burden: 1..3,5 VA (Current circuits) WATTMETERS VARMETERS Dimensions mm 96x96 Approx. weight Kg. 0,55 0,84 0,55 AC. Single-phas WC3V WC2V WC3Vr Three-phase, 3 or 4 wire WC3VI WC2VI WC3VIr 144x144 96x96 AC. SINGLE-PHASE - BALANCED THREE-PHASE UNBALANCED THREE-PHASE 1,00 1,55 1,00 Three-phase, 3 wire WC3VII WC2VII WC3VIIr Three-phase, 4 wire WC3VIIn WC2VIIn WC3VIInr Approx. weight Kg. - Full scale value: 0,6..1,2 Pa Pa = Vn · In (Single-phase, Alternating current) Pa = Vn · In · 3 (Three-phase) If not indicated otherwise, full scale value will be Pa rounded up to 1;1.2; 1.5; 2; 2.5; 3; 4; 5; 6; 7.5; 8 and MULTIPLES Dimensions e b a c ø d Active power model Reactive power model Connection diagrams available on page AI-32. Range nalogue Alternating current 144x144 0,84 WC2Vr WC2VIr 1,55 WC2VIIr WC2VIInr AI-33 ANALOGUE INSTRUMENTS Analogue instruments PHASE METERS (ELECTRONIC) System's power factor measuring. Alternating current - Scale: CAP 0,5 - 1 - 0,5 IND - Frequency: 50 or 60 Hz - Voltage range: ±15 % Vn - Voltage: (Vn): 100, 110 230, 400, 440 V - Current range: 20-120% - Current input: (In): 5A, 1A - Accuracy: 1,5 % of 90 electrical degrees - Burden: 6,5 mA (Voltage circuits) - Burden: 1 VA (Current circuits) 90º SCALE 90º SCALE Dimensions mm 45x52,5 Approx. weight Kg. 0,48 0,48 0,48 0,73 0,73 AC. Single-phas SC5VRE* SC5VE* SC4VE* SC3VE SC2VE Three-phase, 3 wire SC5VRIE* SC5VIE* SC4VIE* SC3VIE SC2VIE 48x48 DIN RAIL 72x72 96x96 144x144 AC. SINGLE-PHASE - BALANCED THREE-PHASE 240º SCALE Dimensions mm 48x48 72x72 96x96 144x144 Approx. weight Kg. 0,48 0,48 0,73 0,73 AC. Single-phas SC5CE* SC4CE* SC3CE SC2CE Three-phase, 3 wire SC5CIE* SC4CIE* SC3CIE SC2CIE AC. SINGLE-PHASE - BALANCED THREE-PHASE * With additional module: MBPF model DIN rail MBPF module 58 48 52,5 45 62 93 90 25 Weight = 0,120 Plug-in connectors a 7 35,5 e 28,5 b c Dimensions d Ø AI-34 Ø 4,3 Models Ranges a b c d e ø SC5VRE 100÷440 52,5 45 75 60 38 M.6 SC5VRIE 100÷440 52,5 45 75 60 38 M.6 Analogue ANALOGUE INSTRUMENTS Analogue instruments Dimensions e d Models Ranges Dimensions ø b a c e d Models Ranges Connection diagrams Single-phase 1 2 3 5 k R 0(S) Connection: K Direct input Connection diagrams v V L1 N L 1 3 K Direct input u U Transf. Voltage Balanced three-phase k Connection: l Current Transf. 1 2 3 5 R S T 2 5 1 3 l L Current Transf. 5 8 u v U V L1 L2 L3 nalogue b a c ø Transf. Voltage AI-35 ANALOGUE INSTRUMENTS Analogue instruments PHASE METERS (INDUCTION) System's power factor measuring. Alternating current - Scale: CAP 0,5 - 1 - 0,5 IND or 0,8 - 1 0,2 IND (90º) CAP 0,1 - 1 - 0,1 IND 4 quadrants (360º) - Accuracy: 1,5 % of 90 electrical degrees - Frequency: 50 or 60 Hz - Voltage range: ±15 % Vn - Burden: 20..30 mA - Voltage: (Vn): 100, 110 (Voltage circuits) 230, 400, 440 V - Burden: 1 VA - Current range: 20-120% (Current circuits) - Current input: (In): 5A, 1A 90º SCALE 360º SCALE Dimensions mm 96x96 Approx. weight Kg. 1,07 1,57 1,10 1,60 AC. Single-phas* SC3V SC2V SC3C SC2C Three-phase, 3 or 4 wire** SC3VI SC2VI SC3CI SC2CI 144x144 96x96 144x144 AC. SINGLE-PHASE - BALANCED THREE-PHASE UNBALANCED THREE-PHASE Approx. weight Kg. 1,40 2,35 1,43 2,38 Three-phase, 3 wire** SC3VII SC2VII SC3CII SC2CII Three-phase, 4 wire*** SC3VIIn SC2VIIn SC3CIIn SC2CIIn * With additional resistor box (external): Model 4.5.1 ** 400 V and 600 V with additional resistor box (external): Model 2.6.1 *** 400 V and 600 V only with additional resistor box (external): Model 2.4.1 Dimensions Dimensions ø ø b a c b a c e e d d Models Ranges Models Ranges Resistor boxes on page AI-38 AI-36 Analogue ANALOGUE INSTRUMENTS Analogue instruments Connection diagrams Single-phase 25 13 k R 0(S) l K Connection: Direct input L1 N Current Transf. 1 3 k R S T Direct input Current Transf. u v u v U V U V 1 3 1 B 3E 8 k R S T Transf. Voltage Direct input 5 2 l K u v u v U V U V Current Transf. L1 L2 L3 Transf. Voltage Unbalanced three-phase, 3 wire (110, 230 V) 1 2 3 7 5 9 8 1 3 7 9 k l R S T K 8 u v u v U V U V L K Direct input 5 2 k l L Current Transf. Connection diagrams L1 L2 L3 Transf. Voltage Unbalanced three-phase, 3 wire (400, 440 V) 1 B 3 7 E9 H 1 3 7 9 5 8 k l k l R S T K u v u v U V U V L Current Transf. Transf. Voltage 1 3 4 6 7 9 2 8 u v k l k l R S T 0 K U L K L Current Transf. Connection diagrams 1 B 3 4 6 7H9 L1 L2 L3 N Transf. Voltage Unbalanced three-phase, 4 wire (400, 440 V) 1 3 4 6 7 9 B H 28 2 8 u v k l k l K U k l L K L K Direct input V k l L K Direct input L1 L2 L3 Unbalanced three-phase, 4 wire (100, 230 V) Connection diagrams 1 2 3 4 6 7 8 9 8 L K Direct input 5 2 B E H R S T 0 Connection: 8 L Connection diagrams Connection: L1 L2 L3 Balanced three-phase (400, 440 V) B E H 2 5 8 Connection: 8 L Connection diagrams 2 5 2 l K Connection: Transf. Voltage Balanced three-phase (100, 230 V) 1 2 3 5 8 Connection: v V L Connection diagrams Connection: u U nalogue 1B 3E H B E H 2 5 L Current Transf. V L1 L2 L3 N Transf. Voltage AI-37 ANALOGUE INSTRUMENTS Analogue instruments RESISTOR BOXES Connection to measuring elements. - Accuracy: 0,5 % Model 1.2.1 1.3.1 1.4.1 1.4.2 1.5.1 1.6.1 Terminals 2 3 4 4 5 6 0,23 0,23 0,24 0,31 0,50 0,25 Approx. weight Kg. 1.6.2 6 0,40 Model 2.2.1 2.3.1 2.4.1 2.4.2 2.5.2 2.6.1 2.6.2 2.6.3 2.7.1 2.8.1 Terminals 2 3 4 4 5 6 6 6 7 8 0,31 0,31 0,31 0,31 0,32 0,32 0,55 0,74 0,40 0,60 Approx. weight Kg. Model 3.3.1 3.3.2 4.2.1 4.3.1 4.4.1 4.5.1 4.6.1 Terminals 3 3 2 3 4 5 6 0,27 0,70 0,90 0,90 0,95 1,00 1,00 Approx. weight Kg. Dimensions Dimensions 2.8.2 8 0,77 4.8.1 8 1,00 Dimensions F C 100 123 A B 17 170 155 A E B 6,5 6,5 + 6,5 AI-38 INST. 74 50 152 120 D 134,5 135 Model 1..1 2..1 Model 3.3.1 3.3.2 Model A 64 99 A 155 270 4.5.1 B 86 121 B 50 100 4.6.1 C 101 148 4.8.1 D 135 235 E 120 220 F 69 102 Analogue ANALOGUE INSTRUMENTS SYNCHRONIZATION RELAYS INSTRUMENTS FOR VESSELS nalogue Analogue instruments AI-39 ANALOGUE INSTRUMENTS Analogue instruments MEASURING INSTRUMENTS FOR VESSELS Recommendations. VOLTMETER Depending on the system voltage, its full scale value will be 1.2 of that voltage as a minimum. This will be marked with a red line. In the event of being connected to voltage transformers, the full scale will be 1.2 of the value of the transformer primary as a minimum. This will be marked with a red line. AMMETER Its full scale value will be 1.3 of the alternator rated current as a minimum. This will be marked with a red line. The transformer current ratio must be as near as possible to the alternator's rated current. WATTMETER Its scale will have a full value between 0.6 and 1.2 of UnxInx√'763. Where (Un) is the rated voltage or the primary of the voltage transformer, and (In) the primary current of the current transformer. The alternator KW value is marked with a red line and in all cases its full scale value must exceed 20% of that value, which means that the inal value will be approximately the same as its KVA. When alternators are synchronised with others, the watt meter scale will be reversed to the left of zero. Its value must be 15% of full scale. In each case the watt meter will be 3-wire unbalanced three-phase. REVERSE POWER RELAY The adjustment value will be the alternator KW value (it will match the red line on the watt meter) and its value cannot be lower than 0.6xUnxInx√'763. Setting is from 2 to 15% of that power. The transformer primary and secondary current and voltage values must be known. It will have a 5 s. delay. AI-40 Analogue ANALOGUE INSTRUMENTS Analogue instruments MEASURING INSTRUMENTS FOR VESSELS MAXIMUM CURRENT RELAY It may be connected to any x/5 A current transformer, but the available auxiliary voltage must be known. SYNCHRONIZING RELAY As a synchronizing auxiliary element, the selection and polarity of the voltage power supply must be correct. The width of the chosen phase and time FORmeters will depend on the level of response sensitivity to the alternators' speed and voltage settings and the value allowed by the group. BAR INSULATION INDICATORS The instrument must be supplied directly by the three phases via a leakage analysis switch and never to the voltage transformer secondaries. The system power supply voltage and the available auxiliary power supply of the alarm circuit will be indicated. This instrument must never be connected to three-phase systems with neutral connected to earth. CURRENT TRANSFORMERS Their power depends on the consumption of the instruments to be connected. At least 10VA in class 0.5 is recommended to avoid accuracy and angle errors. Polarity must be correct. VOLTAGE TRANSFORMERS The TE-15R model is specially designed for this application due to its power and accuracy (25VA, class 1). This allows all instruments that the control equipment usually has to be connected to the secondary without the introduction of ratio or phase errors. No special recommendations are required for other instruments used in vessel control equipment. nalogue Recommendations. AI-41 ANALOGUE INSTRUMENTS Analogue instruments FOR SYNCHRONIZING INSTRUMENTS DOUBLE VOLTMETERS Two moving iron systems. True effective value. - Scale: 90º - Frequency: 45..65 Hz - Accuracy: 1,5 % - Burden: 1,5..3 VA - Measuring range: 100, 110, 230, 400, 440 V EC3VII EC2VII Dimensions mm 96x96 144x144 Approx. weight Kg. 0,31 Model 0,46 DOUBLE VOLTMETERS Measuring range Vn Scales 2x100 V 2x110 V 2x230 V 2x400 V 2x440 V 2x165 V 2x180 V 2x380 V 2x660 V 2x720 V DIFFERENTIAL VOLTMETERS Difference (%) between two synchronizing voltages. - Accuracy: 1,5 % - Burden: 10 mA - Frequency: 50 or 60 Hz - Measuring range: 100, 110, 230, 400, 440 V Model Dimensions Approx. weight DIFFERENTIAL VOLTMETERS ∆ Scales Dimensions ø b a c e e e e d Models Ranges Connection diagrams II I II u L1 N (L2) AI-42 R O(S) Line Generator L1 N(L2) U I v u V v R O(S) Analogue ANALOGUE INSTRUMENTS Analogue instruments DOUBLE FREQUENCY METERS (REEDS OR POINTERS) Double measurement (two systems) of two system frequencies. - Burden: 1,2..2,2 mA - Voltage: (Vn): 100, 110, 230, 400, 440 V FC3VII FC2VII Dimensions mm 96x96 144x144 Approx. weight Kg. 0,87 Model 1,25 DOUBLE FREQUENCY METERS Scales Hz 13 17 21 47..53 46..54 or 56..64 45..55 or 55..65 DIFFERENTIAL FREQUENCY METERS Frequency difference (%) between two systems. - Accuracy: 0,2 % - Voltage range: ±15 % Vn - Frequency: 50 or 60 Hz - Burden: 10 mA - Voltage: (Vn): 100, 110, 230, 400, 440 V Model Dimensions Approx. weight DIFFERENTIAL FREQUENCY METERS 10 - 0 - 10 % ΔHz Scales Dimensions ø e b c a e d Models Ranges Connection diagrams II I II u R O(S) L1 N (L2) Line Generator L1 N(L2) U I v u V U v V nalogue - Accuracy: 0,5 % - Voltage range: ±15 % Vn R O(S) AI-43 ANALOGUE INSTRUMENTS Analogue instruments SYNCHRONOSCOPES Phase synchronisation measurement (frequency and phase equality) between two single-phase or three-phase alternating current systems, or between system and generator. - Accuracy: 1,5 % of 90 electrical degrees - Voltage range: ±15 % Vn - Voltage: (Vn): 100, 110, 230, 400, 440 V - Burden: 20..30 mA - Frequency: 50 or 60 Hz SYNCHRONOSCOPES Dimensions mm 96x96 Approx. weight Kg. 1,37 144x144 1,83 AC. SINGLE-PHAS SC3V-360º AC. Single-phas* SC2V-360º BALANCED THREE-PHASE SC3VI-360º Balanced three-phase** * With additional resistor box (external): ** With additional resistor box (external): SC2VI-360º 100, 110, 230 V: Model 4.5.1 400, 440 V: Model 4.5.1 and 2.4.1 230 V: Model 1.6.1 400, 440 V: Model 2.6.1 and 2.4.1 Dimensions ø b a c e d Models Ranges Resistor boxes on page AI-38 AI-44 Analogue ANALOGUE INSTRUMENTS Analogue instruments CONNECTION DIAGRAMS 25 u v U 26 27 B E H 26 27 B E H 2 5 u v U V V L1 N R 0(S) Red Connection: Direct input Generator Current Transf. Transf. Voltage Single-phase (400, 440 V) Connection diagrams 25 26 27 B E H X Y X Y 26 27 B E H 2 5 u v U u v U V V L1 N R 0(S) Red Connection: Generator Direct input Current Transf. Transf. Voltage Three-phase (100, 110 V) Connection diagrams 2 R S T 5 8 u v u v U V U V 26 28 2 5 8 26 28 u v U Red Connection: Direct input V R S T 5 Transf. Voltage Three-phase (230 V) 8 u v u v U V U V 26 28 B E H 26 28 B E H 2 5 8 u v U Red Connection: Direct input R S T 5 L1 L2 L3 Transf. Voltage Three-phase (400, 440 V) 8 u v u v U V U V Direct input 26 28 B E H X Z X Z 26 28 B E H 2 5 8 u v U Red Connection: V Generator Current Transf. Connection diagrams 2 L1 L2 L3 Generator Current Transf. Connection diagrams 2 nalogue Single-phase (100, 110, 230 V) Connection diagrams V L1 L2 L3 Generator Current Transf. Transf. Voltage AI-45 ANALOGUE INSTRUMENTS Analogue instruments LAMP SYNCHRONOSCOPE Genset synchronization for manual operation. ALTERNATING CURRENT - NAVAL SERIES - Frequency: 50 or 60 Hz - Voltage: 110, 230, 400 or 440 V ±20 % Model SC3VL SC2VL Dimensions mm 96x96 144x144 Approx. weight Kg. 0,20 0,26 Its operation is based on detecting voltage between similar phases in the two systems to be synchronized, so that when there is zero voltage the operator may give the connection order. Dimensions T S S R R 26 2 27 5 G2/ LÍNE d 5 2 L1 26 b T c G1 ø a Connection diagrams Models Ranges L2 27 Internal scheme SEQUENCE METER / SEQUENCE RELAY WITH ALARM Displays the correct phase sequence in a three-phase system and provides a contact to allow the connection of the receiving device. ALTERNATING CURRENT - NAVAL SERIES - Frequency: 50 or 60 Hz - Burden: 1,2 VA - Voltage: 110, 230, 400 or 440 V ±20 % Model RSQ Dimensions mm 96x96 Approx. weight Kg. 0,35 Has three LEDs showing: - Inverse sequence (red), marked L3-L3-L2. - Direct sequence (green), marked L3-L2-L3. - Operates enable relay (green), marked OK. Close enable output: 250 V, 8A relay Dimensions 12 13 14 2 5 b a ø c Connection diagrams 8 d 2A L1 AI-46 L2 L3 Models Ranges Analogue ANALOGUE INSTRUMENTS Analogue instruments SYNCHRONOSCOPE / DIGITAL SYNCHRONIZING RELAY Allows both the phase and parameters of the two voltages from two systems to be displayed and their synchronization. - Input: 110, 230, 400 or 440 V ±20 % - Frequency range: 45 a 65 Hz - Phase-difference range: ±180º - Voltage-difference range: ±100 % Model - Accuracy: 0,5 % - Accuracy: 0,1 % - Accuracy: 1 % - Accuracy: 1 % RSS1 (2 wire) RSS3 (3 wire) Dimensions mm 96x96 96x96 Approx. weight Kg. 0,85 0,85 SYNCHRONOSCOPE / DIGITAL SYNCHRONIZING RELAY V nalogue ALTERNATING CURRENT - NAVAL SERIES 110 ó 230 V 110, 230, 400, ó 440 V Has a rotating display showing the phase between two voltages and two number indicators which display their module. Allows the current module difference, phase difference and trip time to be set. Once the enable conditions have been met, the output relay closes, either for a ixed time (300 ms) or continuously while the condition lasts. Receives power from the bus/bars signal. When operating as an automatic synchronizer it supplies acceleration/delay pulses for the alternator speed. LEDs on the front display the operation of the 8 output relays. The front keypad programs: - Voltage difference: ±10 % - Phase difference: ±20º - Permanent time: 0,1 - 5 s. - Operate enable relay: Pulse, 300 msg. - Continuous (SYNC) - Operate control relays(SPEED) Connection diagrams SYNC GEN LIN. L1 L2 12 L1 L2 4 59 NC NO CC 78 VELOC. SYNC. 14 15 16 GEN LIN. L1 L2 L3 12 36 L1 L2 L3 4 5 NC NO C 97 8 Aux. v LINE L1 L2 L3 L1 L2 L3 G RSS1 L1 L2 L3 RSS3 Dimensions b a c ø d Models C 14 15 16 Aux. v LINE G VELOC. L1 L2 L3 Ranges AI-47 ANALOGUE INSTRUMENTS Analogue instruments SYNCHRONIZING EQUIPMENT Equipment with three instruments, double or differential voltmeter, double or differential frequency meters and synchronoscope, for connecting two generators in parallel, or connecting a generator with system. Position: Vertical (as column with 180º turn) Horizontal (with two supports) Technical speciications: see instrument data.. Model VOLTMETERS FREQUENCY METERS ES3V EC3VII or CC3VGD FC3VII or FC3AD SYNCHRONOSCOPES SC3V-360º ES3VI EC3VII or CC3VGD FC3VII or FC3AD SC3VI-360º ES2V EC3VII or CC2VGD FC2VII or FC2AD or FC2AD SC2V-360º ES2VI EC3VII or CC2VGD FC3VII or FC2AD or FC2AD SC2VI-360º ES3C CC3CGD FC3CD SC3V-360º ES3CI CC3CGD FC3CD SC3VI-360º ES2C CC2CGD FC2CD SC2V-360º ES2CI CC2CGD FC2CD SC2VI-360º 90º SCALE 360º SCALE Dimensions mm 410x223x120 576x258x170 410x223x120 576x258x170 Dimensions mm 96x96 144x144 96x96 144x144 Approx. weight Kg. 5,70 9,00 5,80 8,70 ES3C ES2C EQUIPMENT INSTRUMENTS SINGLE-PHASE Single-phase ES3V ES2V BALANCED THREE-PHASE Balanced-three phase ES3VI Dimensions ES2VI ES3CI ES2CI c e 8,5 g e d a f 90º 90º Models b Connection diagrams Single-phase 2 5 5 26 27 R O(S) System AI-48 Generator U V u v u v U Three-phase 26 28 26 27 u v 2 Connection diagrams V Connection with voltage transf. 2 L1 N R S T 5 System 8 26 28 Generator U V 2 5 8 u v u v U V U V Connection with voltage transf. L1 L2 L3 Analogue ANALOGUE INSTRUMENTS Analogue instruments REVERSE POWER RELAY ALTERNATING CURRENT - NAVAL SERIES - Accuracy: ±1,5 % (de la Pn) - Frequency: 50 or 60 Hz RIC2VI Model Dimensions mm Approx. weight Kg. 144x144 1,25 REVERSE POWER RELAY 100, 110, 230, 400 or 440 Un V In A ../5 Aux. v. V 100, 230, or 400 - Un range: -40 ÷ +20% - Aux. v. range: ±20% - In range: 20 ÷ 120% - Scale: UnxInx√3xcosφ (KW) - Hysteresis: <1% (of Pn) - Adjustment limit: 2-15% (of the alternator Pn in KW) - Delay for output signal: 5 ± 0.3 secs. (optional, without delay) - Output contacts power: Max 200 Va, 400 V, 5A Two lights indicators determine the period of time between overload and the closing of the output relay Connection diagrams 1 2 3 5 8 14 15 16 17 18 19 20 21 2 V. Aux. k G K L1 R L2 S L3 T L R S T u v u v U V U V b a ø c L1 L2 L3 - With overload: 15 and 16 closed after time-out - Instant relay: 18 common, 17 open, 19 closed - With overload: 18 and 17 closed Dimensions d Ranges 8 l - Output contacts: Timing switch relay: 15 common - Without auxiliary voltage: 14 open, 16 closed - With auxiliary voltage: 15 and 14 closed Models 5 nalogue Power relay to limit the inverse power (antimotoring) between two alternating current generators connected in parallel. AI-49 ANALOGUE INSTRUMENTS Analogue instruments SYNCHRONISING RELAY Electronic relay for synchronization of two alternating current generators comparing their voltage, phase and frequency. ALTERNATING CURRENT - NAVAL SERIES - Precisión en fase ±2,5 % - Frequency: 50 or 60 Hz - Time: ±0,5 s. - Un Range: ±15 % RSC2 Model Dimensions mm Approx. weight Kg. 144x144 2,00 SYNCHRONISING RELAY Un V 2x110, 230, 400 ó 440 A check adjusts the phase difference from 5 to 40 electrical degrees, and another adjusts the minimum time from 0.2 to 5 secs, during which this difference must be maintained. When both FORmeters go into the set limits, the output relay operates the synchronizing switch and an LED indicates that coupling may be carried out. To adjust operating limit, remove security cover or screw. Connection diagrams LINE R S T 1 2 3 4 5 6 7 8 9 10 110 220 u v U V 110 220 v V U U G L1 L2 L3 Output relay: 1 switching contact (max. 200 VA, 250 V, 5 A AC.) Dimensions b a c ø d Models AI-50 Ranges Analogue ANALOGUE INSTRUMENTS Analogue instruments MAXIMUM CURRENT RELAY Electronic overcurrent relay which detects the current level in each phase in three-phase alternators. - Accuracy Current: ±2,5 % (Trip set value) Time: ±3 % ±1 sg. of set value - Frequency: 50 or 60 Hz RMC2 RMC2A Dimensions mm 144x144 144x144 Approx. weight Kg. 1,33 Model 1,33 MAXIMUM CURRENT RELAY nalogue ALTERNATING CURRENT - NAVAL SERIES In A ../5 ../5 Aux. v. V - 100, 110, 230, 400 or 440 A.C. ±30% - Overload: 10 In for 1 s - Aux. v range: ±30 % - Hysteresis: <0.16 A - Adjustment limit: 0.6÷1.6 (of In independent of each phase) - Delay on output signal: (independent of overload): 1 from 2 to 60 secs in phases II and III - Output contacts power: Max. 200 VA, 400 V, 5 A - Indicators to check operation time. - To adjust operating limit, remove security cover or screw. Connection diagrams RET. I RET. II/III INST. II/III 1 3 4 6 7 9 14 15 16 17 18 19 20 21 23 24 25 V. Aux. k l R S T 0 k l K L K L1 L2 L3 N k l L K L - Output contacts: Phase I, Relay I - 15-14 switch normally open and 15-16 closed - In overload: 15-14 closed after time-out - Phases II/III: Relay II/III, 18-17 switch normally open and 18-19 closed - With auxiliary voltage, without overload, 18-17 closed - In overload: 18-19 closed after time-out - Instant relay. Switch, 24-23 open, 24-25 closed In overload, 24-23 closed - On standby, 18-17 is open and 18-19 closed - With auxiliary voltage, without overload, 18-19 remain closed - In overload, 18-17 closed after time-out - RMC2A: The same features as RMC2 except that II/III relay operation is reversed Dimensions b a c ø d Models Ranges AI-51 ANALOGUE INSTRUMENTS Analogue instruments MIN-MAX VOLTAGE AND FREQUENCY RELAY Instrument for voltage and frequency control in a three-phase or single-phase system. ALTERNATING CURRENT - NAVAL SERIES - Accuracy: ±2 % - Frequency: 50 or 60 Hz RUFC2 Model Dimensions mm Approx. weight Kg. 144x144 1,25 MINIMUM-MAXIMUM VOLTAGE AND FREQUENCY RELAY Aux. v. V 100, 110, 230, 400 or 440 V 110, 230 or 400 ±30% A.C. . - Un range: -40 ÷ +20 % - Aux. v range: ±30 % MINIMUM VOLTAGE SETTING - Un range: 60-100 % (Accuracy 1%) - Timer: 0-5 s. (Accuracy 2% ±0.2 s) MINIMUM FREQUENCY SETTING - Range: 45-55 / 55-65 Hz (Accuracy 1%) - Timer: 0-10 s. (Accuracy 2% ±0.2 s) MAXIMUM VOLTAGE SETTING - Un range: 80-120 % (Accuracy 1%) - Timer: 0-5 s. (Accuracy 2% ±0.2 s) MAXIMUM FREQUENCY SETTING - Range: 45-55 / 55-65 Hz (Accuracy 1%) - Timer: 0-10 s. (Accuracy 2% ±0.2 s) Instant alarm and relay operation indicators. To adjust operating limit, remove security cover or screw. Connection diagrams <%Un <%Hz >%Un >%Hz 2 5 14 15 16 17 18 19 20 21 23 24 25 26 27 28 2 5 u v Aux. v L1 L2 L3 R S T R S T U V L1 L2 L3 - One switch output relay each setting (max. 200 VA, 400 V). - Hysteresis <2 % Dimensions b a c ø d Models AI-52 Ranges Analogue ANALOGUE INSTRUMENTS Analogue instruments INSULATION INDICATORS ALTERNATING CURRENT - NAVAL SERIES - Accuracy: ±1,5 % (of Un scale arch) - Frequency: 50 or 60 Hz IAC3V IAC2V IAC3VA Dimensions mm 96x96 144x144 96x96 Approx. weight Kg. 0,92 1,20 0,92 Model IAC2VA 144x144 1,20 INSULATION INDICATORS 230-400 or 440 V V Aux. v. V 110 or 230 A.C. - - Scale; 0..50..0 MΩ (1 MΩ to centre) - Aux. v. range: ±20% - Guaranteed number of operations: 107 - Output contact: Switched at 2A, 230 V A.C. 200 VA - Scale: 0-100 (Insulation comparison) - Setting accuracy: ±3% of scale value - To adjust operating limit, remove security cover or screw Connection diagrams IAC2VA 8 37 46 76 50 ø4 42 IAC2V Ajust. 2 4 6 14 15 16 20 21 R G S Ajust. 2 4 6 T R G Aux. v L1 L2 L3 R S T nalogue Instrument which detects and measures an earth insulation failure in a three-phase circuit with insulated neutral with direct and continuous connectio to the system (position G on switch). The IAC_VA models have a built-in alarm system with continuous adjustable setting device from 0 and 5 MΩ. R S T S T L1 L2 L3 If the insulation drops below the selected level, an internal spdt micro-relay closes the alarm circuit as the indicator, located beside the setting device, comes on. Moving the switch to position R, S or T, allows the faulty phase to be located. The phase with the lowest reading will have the insulation fault. Dimensions b a c ø d Models Ranges AI-53 ANALOGUE INSTRUMENTS Analogue instruments RUDDER DEGREE INDICATOR FOR VESSELS Rudder position indicator through connection to potentiometer using resistance variations.. DIRECT CURRENT - NAVAL SERIES - Scale: 90º - Accuracy: ±1,5 % - Burden: 2000 Ω/V CCb8 Model Dimensions mm Approx. weight Kg. 130x100 0,25 RUDDER DEGREE INDICATOR Scales Ranges º 40-0-40 or 45-0-45 V 7-0-7 or 12-0-12 Standardised scales. PORT (red arc); STARBOARD (green arc). Lighting: Grade line at 12 V (two 2W lamps). The central value or 0º on the scale coincides with the potentiometer centre. Connection diagrams Dimensions c ø b g POT. EXTERNO a1 e h i R=POT/2 2V R=POT/2 Models a d f Ranges axa1 b c d V 130x100 66 67 59 100+0,8 100 CCb8 e f g h i ø 13 13 M.4 M.4 R.P.M. INDICATOR FOR VESSELS Supplied by a generator located at the propeller axis indicating its r.p.m. AHEAD or ASTERN. DIRECT CURRENT - SERIE NAVAL - Scale: 240º - Accuracy: ±1,5 % - Burden: 100 Ω/V CC2C Model Dimensions mm Approx. weight Kg. 144x144 0,68 R.P.M. INDICATOR FOR VESSELS (MAIN MOTOR) Scales r.p.m.* 150-0-150, 180-0-180, 200-0-200 or 300-0-300 Ranges V** 10-0-10 *Standardised scales. ASTERN (red arc); AHEAD (green arc). ** Standardised ranges, according to voltage/speed curve (V.DC./r.p.m.) of the generator. Full scale adjustment: With built-in potentiometer ±10 % of total value. Lighting: Translucent at 12 or 24 V. Connection diagram Dimensions ø b a c e + d + Models - Voltage AI-54 Ranges Analogue ANALOGUE INSTRUMENTS Analogue instruments VOLTAGE AND CURRENT SURVEILLANCE RELAY ALTERNATING CURRENT - Detection range: · Unbalance 0 to 20 % of Vn. · Undervoltage 80 to 100 % of Vn. · Unbalance 0 to 20 % of In. · Overvoltage 120 % of Vn. - Class: 1 - Output features: 250 V, 3 A, 300 VA. - Burden: 0.48 VA per phase Model RVIA (three-phase, 3 wire) RVIB (three-phase, 4 wire) Dimensions mm 150x70x112 150x70x112 Approx. weight Kg. 1,20 1,20 VOLTAGE AND CURRENT SURVEILLANCE RELAY 110, 230 or 400V V A nalogue Designed for supervising measurement board connections in installations or substations. Detection of Current Unbalance, Voltages, Overvoltage and Undervoltage. ../5 A or ..1/A Current faults activate an alarm relay and any form of voltage fault activates a second relay. Has an indicator to show "CORRECT" status and two indicators to show "CURRENT FAILURE" and "VOLTAGE FAILURES". Controls on the front allow comparison levels to be selected to set off the alarm. Two controls are for voltage, for unbalance levels (from 0 to 20 %), and undervoltage levels (from 80 to 100 %) and a third for current (from 0 to 20 %). To operate, the three phases to be supervised are connected to the voltage inputs and the three currents pass through the associated toroidal transformer. Dimensions 150 70 73 35 112 Connection diagrams ±10 9 90 8 4 10 32 ALARMA V ±20 0 80 100 TENSIÓN ALARMA I 20 INTENSIDAD CORRECTO ALARMAS Un = 69,3 V RVI - B 0 1 R S T N Connections: Voltages, connected to terminals marked R, S, T and N. For three wire equipment, obviously neutral is not connected. Currents, the toroidal transformer output is connected to terminals marked I (8 and 9). Output relays have potential-free contacts and are insulated for complete connection lexibility. AI-55 ANALOGUE INSTRUMENTS Analogue instruments NAVAL SURVEILLANCE RELAY - RSN PRODUCT DESCRIPTION RSN is a naval supervision relay whose mission is to protect the generating sets usually installed on board of vessels. It is a multifunction equipment built with a microprocessor which makes RNS a versatile and reliable device. It can be connected to a centralized control board through a serial port so that the coniguration and data sending of the different operations can be carried out. A liquid crystal screen facilitates the display of the measured data as well as the local coniguration of the equipment through a keypad located in front of the device. RSN (Three-phase, 4 wire) Model Dimensions mm Approx. weight . Kg. 150x75x115 1,20 NAVAL SURVEILLANCE RELAY -RSN 500 V. (line-line) Max. V A ../5 A Aux. v V 110, 230 or 400 V A.C. Aux. v V 24-48-110 V D.C. V UNIVERSAL 85-264 V A.C and D.C. . Aux. v MEASURING ENVIRONMENT ELECTRICAL QUANTITY Voltage (Line-to-Neutral) Voltage (Line-to-Line) Neutral current Curren, Active Power Reactive Power Apparent Power Power facto Frequency THD Current THD Voltage Neutral current Symbol V V A kW kVAr kVA PF Hz A V A A Total Average ● ● ● ● ● ● ● ● ● Average ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● Average FUNCTIONAL DESCRIPTION RSN relay can be set as: - RMC2 Over current relay - RU H Over voltage relay - RU L Under voltage relay - RUCM Maximum and minimum average voltage and maximum average current - RIC Direct power and reverse power relay - RUF Maximum and minimum voltages and maximum and minimum frequency relay - RUNB Unbalanced voltages, currents, over voltages and under voltages relay Setting can be modiied through the keypad or the serial line. The different values assigned to each input, as well as the alarm values must be set for each mode. AI-56 Analogue ANALOGUE INSTRUMENTS Analogue instruments NAVAL SURVEILLANCE RELAY - RSN SERIAL OUTPUT Operations to be carried out through the keyboard: Type: Options Output Protocol - Rated voltage value of the installation. - Rated current transformer value. - Equipment identity in a RS-485 net. - Baud rate of the serial line RS-485 - Operating mode of the output relays - Reference value and delays used in relay operation RS485 (DB9 male connector) RS232(DB9 female connector) MODBUS/JBUS MOUNTING Equipment can be mounted in EN 50022 DIN RAIL or through screws into a board Operations to be carried out through the serial line: DIMENSIONS. - Equipment settings. - Identity and serial number settings. - Reading of the system FORmeters. - Change of voltage, current and energy range. - Change of the access code to keypad setting. - Change of the baud rate - Other functions related to different options installed in the equipment Box: ERNI LDG-A-46. 150x75x115 mm. ACCEPTABLE OVERLOADS Current circuits 2*In continuamente 20*In durante 3 s. 40*In durante 1 s. 1,22*Un continuous Voltage circuits TECHNICAL SPECIFICATIONS INSULATION (as EN 61010) Input Current: Voltage: Auxiliay supply: 5 A. 500 V (Line-to-Line) max 110, 230, or 400 V AC.±20% 24, 48, 110 V DC ±20%. Universal from 85 to 264 VDC, 47-65 Hz. DIGITAL OUTPUTS Number of outputs: Type: Six SPDT relay 230 V; 3 A; 300 VA Output relays are grouped in pairs with one common to each point which must be taken into account in the external circuit. There is no load limitation in the contacts, therefore, they must be protected by some external protection device. Connections are displayed on the previously shown diagram. nalogue SETTING Insulation grade. Category of the installation Pollution grade Rated values Double III 2 Voltage, 500V (350 V to GND) Current, 350 V Output, 50 V Serial line, 50 V Digital output, 300 V AI-57 ANALOGUE INSTRUMENTS Analogue instruments NAVAL SURVEILLANCE RELAY - RSN Required data is displayed on screens in the following igure: TEXT VARIABLE DESCRIPTION RMC2 - OVER CURRENT RELAY IL1 IL2 IL3 TIL1 TIL2 TIL3 VALUE_ALAR0 VALUE_ALAR1 VALUE_ALAR2 DELAY_ALAR0 DELAY_ALAR1 DELAY_ALAR2 REFERENCE % FOR I L1 REFERENCE % FOR I L2 REFERENCE % FOR I L3 DELAY FOR I L1 IN TENTHS OF SECONDS DELAY FOR I L2 IN TENTHS OF SECONDS DELAY FOR I L2 IN TENTHS OF SECONDS RUH - OVER VOLTAGE RELAY U L1 U L2 U L3 T U1 T U2 T U3 VALUE_ALAR0 VALUE_ALAR1 VALUE_ALAR2 DELAY_ALAR0 DELAY_ALAR1 DELAY_ALAR2 REFERENCE % FOR U L1 REFERENCE % FOR U L2 REFERENCE % FOR U L3 DELAY FOR U L1 IN TENTHS OF SECONDS DELAY FOR U L2 IN TENTHS OF SECONDS DELAY FOR U L2 IN TENTHS OF SECONDS RUL - UNDER VOLTAGE RELAY U L1 U L2 U L3 T U1 T U2 T U3 VALUE_ALAR0 VALUE_ALAR1 VALUE_ALAR2 DELAY_ALAR0 DELAY_ALAR1 DELAY_ALAR2 REFERENCE % FOR U L1 REFERENCE % FOR U L2 REFERENCE % FOR U L3 DELAY FOR U L1 IN TENTHS OF SECONDS DELAY FOR U L2 IN TENTHS OF SECONDS DELAY FOR U L2 IN TENTHS OF SECONDS RUCM - MAXIMUM AND MINIMUM AVERAGE VOLTAGE AND MAXIMUM AVERAGE CURRENT UM H UM L IM H TUMH TUML TIMH VALUE_ALAR0 VALUE_ALAR1 VALUE_ALAR2 DELAY_ALAR0 DELAY_ALAR1 DELAY_ALAR2 REFERENCE % FOR MAXIMUM RATED VOLTAGE REFERENCE % FOR MMINIMUM RATED VOLTAGE REFERENCE % FOR MAXIMUM RATED VOLTAGE DELAY FOR U MAXIMUM RATED VOLTAGE IN TENTHS OF SECOND DELAY FOR U MAXIMUM RATED VOLTAGE IN TENTHS OF SECOND DELAY FOR I MAXIMUM RATED VOLTAGE IN TENTHS OF SECOND RIC - DIRECT POWER AND REVERSE POWER RELAY Pd PI T Pd T PI VALUE_ALAR0 VALUE_ALAR1 DELAY_ALAR0 DELAY_ALAR1 REFERENCE % FOR DIRECT ACTIVE POWER REFERENCE % FOR REVERSE ACTIVE POWER DELAY FOR DIRECT POWER IN TENTHS OF SECOND DELAY FOR DIRECT POWER IN TENTHS OF SECOND RUF - MAXIMUM AND MINIMUM VOLTAGES AND MAXIMUM AND MIN FREQUENCY UH UL Fr H Fr L TUHL TFHL VALUE_ALAR0 VALUE_ALAR1 VALUE_ALAR2 VALUE_ALAR3 DELAY_ALAR0 DELAY_ALAR1 REFERENCE % FOR MAXIMUM VOLTAGE (1-2-3) REFERENCE % FOR MAXIMUM VOLTAGE (1-2-3) FOR MAXIMUM FREQUENCY FOR MAXIMUM FREQUENCY DELAY FOR MAXIMUM OR MINIMUM VOLTAGE IN TENTHS OF SECOND DELAY FOR MAXIMUM OR MINIMUM VOLTAGE IN TENTHS OF SECOND RUNB - UNBALANCED VOLTAGES, CURRENTS, OVER VOLTAGES AND UNDER VOLTAGES RELAY UUnb Iunb UH UL TUUn TIUn TUHL AI-58 VALUE_ALAR0 VALUE_ALAR1 VALUE_ALAR2 VALUE_ALAR3 DELAY_ALAR0 DELAY_ALAR1 DELAY_ALAR2 REFERENCE % FOR VOLTAGE UNBALANCE FOR CURRENT UNBALANCE FOR MAXIMUM VOLTAGE (1-2-3) FOR MINIMUM VOLTAGE (1-2-3) DELAY FOR UNBALANCED VOLTAGE IN TENTHS OF SECOND DELAY FOR UNBALANCED CURRENT IN TENTHS OF SECOND DELAY FOR MAXIMUM OR MINIMUM VOLTAGE IN (1-2-3) TENTHS OF SECOND Analogue ANALOGUE INSTRUMENTS Analogue instruments N 0 T GEN S R K L k l K L k l K L L3 k l L2 L1 V. Aux. 2 5 8 10 1 14 15 16 17 18 3 4 6 7 9 22 23 24 25 26 Relay BLOCK I Relay BLOCK III RS 485 2 3 5 20 27 28 29 30 31 Relay BLOCK II RS 232 21 RD TD 5 9 LL+ GND 4 COM L O A D nalogue NAVAL SURVEILLANCE RELAY - RSN AI-59 ANALOGUE INSTRUMENTS Analogue instruments CURRENT OR POWER RELAY R2M / R2MC R2M is an equipment that measures current or power in a three phase network. Its functioning mode is based on the activation of the contacts of a step control relay when the range, which is chosen on the frontal panel, is exceeded. It has a x/5A current input that must be connected to the secondary of a current transformer and to the voltage input that can be directly connected to the net. Depending on the connection and on the chosen mode it can be used as: - R2M –CURRENT RELAY R2M – ACTIVE POWER RELAY R2M – REVERSE POWER RELAY R2MC – REACTIVE CURRENT RELAY TECHNICAL FEATURES GENERAL VOLTAGE INPUT Case material Dimensions Connection Max. wire diameter Rated voltage (Un) Burden Frequency 230 or 400 V A.C < 3 VA, 2W 50 - 60 Hz ABS, UL94 V0 (2 DIN modules) 35 mm Terminals with screw 12 mm2 (inputs) 2,5 mm2 (pulse output) DIN RAIL 35 mm Mounting CURRENT INPUT CONNECTION DIAGRAM Current (In) Burden Permanent overload x/5 A < 0,2 VA 1,2 In L1 K L k l L O A D L2 - Current relay - Active power relay - Reverse power relay Range of the variable adjustment: Ton connection delay Toff disconnection delay 5 A; 0-100% 4s 4s - Reactive current relay Range of the variable adjustment: Ton connection delay Toff disconnection delay 0,15....2 A 5s 2s L3 k l S1 S2 0 Relé 16 15 18 L1 K L k l -Current relay L O A D L2 L3 -Active power relay -Reverse power relay N k l S1 S2 A2 A1 0 autosupplied Relay green LED: supply Red LED: connected relay. AI-60 A2 A1 100 % Output relay Insulation rated voltage Ui 250 V A.C. A.C.11 Ie/Ue 4 A / 240 V A.C. D.C.11 Ie / Ue 1 A / 110 V D.C. Auxiliary voltage: Connection indication - Reactive current relay 100 % 16 15 18 Analogue