ENGINEERING TEL: 024 7684 1750 FAX: 024 7662 1796 Website: http://www.woodwayengineering.co.uk A B C D DATA SHEET HEADLAMP FLASHER Model – HF1000 E SPECIFICATION: SIZE: 133mm x 63.5mm x 31mm FIXING HOLE CENTRES: 124mm x 38mm FIXING HOLE DIA: 5mm INPUT VOLTAGE: 12Vdc. OUTPUT FLASHRATE: CONNECTION: SCREW TERMINALS OPERATION: The unit is designed to work on vehicles with either –ve chassis or +ve chassis and has alternating and simultaneous flash outputs. The unit has an inhibit facility which, when connected, disables the unit when the vehicle lights are in use e.g. at night. MOUNTING: The unit is not potted and is not waterproof it should, therefore, be mounted in a cool and dry location. It is recommended that it is not mounted in the engine compartment of a vehicle nor in a location where it may be subject to road spray. WIRING: All wiring should be sized as indicated on the wiring diagrams. The use of wire of a smaller csa than that shown is not recommended and will invalidate the warranty. All wires connecting to the terminal block should be terminated with bootlace ferrules or crimp terminals of the correct size for the wire used. It is the responsibility of the customer to ensure that the correct terminals and crimp tools are used. All switches, fuses etc are to be supplied by the customer. 8S:\ENGINEERING\Product Installation\DATASHTS\HF1000 Issue C.DOC WIRING FOR SIMULTANEOUS AND ALTERNATING FLASH +VE SWITCHING HEADLIGHTS A B 1 2 3 4 C D E V C S AO 1 2 0.5 UNIT INHIBIT +ve SUPPLY FROM VEHICLE LIGHTS 0.5 1.0 N/S HEADLIGHT MAIN BEAM VEHICLE N/S HEADLIGHT MAIN BEAM SUPPLY (+VE) -VE CHASSIS 0.5 0.5 S Off A 0.5 -VE CHASSIS SWITCH S = SIMULTANEOUS A = ALTERNATING FUSE BATTERY +Ve 1.0 O/S HEADLIGHT MAIN BEAM 3A 2.0 VEHICLE O/S HEADLIGHT MAIN BEAM SUPPLY (+VE) FUSE BATTERY +Ve 20A -VE CHASSIS WIRING FOR SIMULTANEOUS FLASH ONLY +VE SWITCHING HEADLIGHTS A B 1 2 3 4 C D E V C S AO 1 2 0.5 UNIT INHIBIT +ve SUPPLY FROM VEHICLE LIGHTS 0.5 1.0 N/S HEADLIGHT MAIN BEAM -VE CHASSIS VEHICLE HEADLIGHT MAIN BEAM SUPPLY (+VE) 0.5 0.5 -VE CHASSIS S Off ON-OFF SWITCH FUSE 1.0 BATTERY +Ve 3A O/S HEADLIGHT MAIN BEAM VEHICLE HEADLIGHT MAIN BEAM SUPPLY (+VE) 2.0 FUSE BATTERY +Ve 20A -VE CHASSIS WIRING NOTES: For alternating only operation fit a single pole on-off switch and wire to terminal D/A and +ve. For simultaneous only operation fit a single pole on-off switch and wire to terminals D/S and +ve. For both alternating and simultaneous operation fit an ‘on’-‘off’-‘on’ switch and wire one ‘on’ position to terminal D/A, the other ‘on’ position to terminal D/S and the pole to +ve. UNIT INHIBIT: It is recommended that this feature is enabled to prevent the operation of the unit when the vehicle lights are switched on. To enable the unit inhibit connect a +ve supply, when the side-lights are operated, to terminal E1. S:\ENGINEERING\Product Installation\DATASHTS\HF1000 Issue C.DOC WIRING FOR SIMULTANEOUS AND ALTERNATING FLASH -VE SWITCHING HEADLIGHTS A B 1 2 3 4 C D E V C S AO 1 2 0.5 UNIT INHIBIT +ve SUPPLY FROM VEHICLE LIGHTS 0.5 1.0 N/S HEADLIGHT MAIN BEAM VEHICLE N/S HEADLIGHT MAIN BEAM –VE SWITCHED 0.5 -VE CHASSIS 0.5 +VE S Off A 0.5 SWITCH S = SIMULTANEOUS A = ALTERNATING FUSE BATTERY +Ve 1.0 O/S HEADLIGHT MAIN BEAM 3A VEHICLE O/S HEADLIGHT MAIN BEAM –VE SWITCHED 2.0 BATTERY -Ve +VE WIRING FOR SIMULTANEOUS FLASH ONLY -VE SWITCHING HEADLIGHTS A B 1 2 3 4 C D E V C S AO 1 2 0.5 UNIT INHIBIT +ve SUPPLY FROM VEHICLE LIGHTS 0.5 1.0 N/S HEADLIGHT MAIN BEAM -VE CHASSIS VEHICLE HEADLIGHT MAIN BEAM -VE SWITCHED 0.5 +VE 0.5 S Off ON-OFF SWITCH FUSE 1.0 BATTERY +Ve 3A O/S HEADLIGHT MAIN BEAM VEHICLE HEADLIGHT MAIN BEAM -VE SWITCHED 2.0 BATTERY -Ve +VE WIRING NOTES: For alternating only operation fit a single pole on-off switch and wire to terminal D/A and +ve. For simultaneous only operation fit a single pole on-off switch and wire to terminals D/S and +ve. For both alternating and simultaneous operation fit an ‘on’-‘off’-‘on’ switch and wire one ‘on’ position to terminal D/A, the other ‘on’ position to terminal D/S and the pole to +ve. UNIT INHIBIT: It is recommended that this feature is enabled to prevent the operation of the unit when the vehicle lights are switched on. To enable the unit inhibit connect a +ve supply, when the side-lights are operated, to terminal E1. S:\ENGINEERING\Product Installation\DATASHTS\HF1000 Issue C.DOC