DALI MCU Digital rotary dimmer Online-Training general I handling I wiring diagramm I applikation I DALI MCU digital rotary dimmer General 2 230V/50 Hz 2 • The DALI MCU ist a rotary dimmer with DALI output for dimming of luminaires- or transformers with DALI interface • Dimming solutions are easy realisable, no DALI adressing necessary • The DALI MCU is adaptable in all standard switches, operation point extension by easy parallel connection DALI MCU | Seite 2 general I handling I wiring diagramm I applikation I DALI MCU digital rotary dimmer Handling • Usage of existing cover DALI MCU | Seite 3 general I handling I wiring diagramm I applikation I DALI MCU digital rotary dimmer Handling • Usage of existing cover • Easy integration in standard switches DALI MCU | Seite 4 general I handling I wiring diagramm I applikation I DALI MCU digital rotary dimmer Operation • On/off – press • Brightness – rotate Special functions • configure switch-on brightness – double click • Set/cancel minimum basic brightness – push knob until blinking confirmation DALI MCU | Seite 5 general I handling I wiring diagramm I applikation I max. 300m DALI MCU digital rotary dimmer Wiring diagram N L1 + DALI MCU | Seite 6 - general I handling I wiring diagramm I applikation I DALI MCU digital rotary dimmer Wiring diagram DALI (DA) N 2 PE z.B. NYM 5x... L1 DALI (DA) max. 300m • DALI control cable as part of a sheated cable N L1 + DALI MCU | Seite 7 - general I handling I wiring diagramm I applikation I DALI MCU digital rotary dimmer Wiring diagram with 1 operation point L1 N active DALI MCU (at mains supply) L1 N L1 N • Up to 25 DALI ECG by one active DALI MCU DALI MCU | Seite 8 general I handling I wiring diagramm I applikation I DALI MCU digital rotary dimmer Wiring diagram with 2 operation points L1 N Active DALI MCU (at mains supply) L1 N L1 N + passive DALI MCU (without mains supply) • Up to 25 DALI ECG by one active DALI MCU • 2nd operation point by easy parallel connection, please look at polarity + DALI MCU | Seite 9 general I handling I wiring diagramm I applikation I DALI MCU digital rotary dimmer Wiring diagram with 2 operation points L1 N active DALI MCU (at mains supply) L1 N L1 N + active DALI MCU (at mains supply) • Up to 50 DALI ECG by 2 active DALI MCU • Max. 2 active DALI MCU and 2 passive DALI MCU (max. 4) operation points + DALI MCU | Seite 10 general I handling I wiring diagramm I applikation I DALI MCU digital rotary dimmer Application example with 2 operation points 230V/ 50Hz 25 DALI ECG 300m cable lenght 2nd operation point (respect polarity DALI cable) DALI MCU | Seite 11 general I handling I wiring diagramm I applikation I DALI MCU digital rotary dimmer Application example with 2 operation points 230V/ 50Hz 300m cable length 50 DALI ECG by 2nd DALI MCU (at mains supply) DALI MCU | Seite 12 general I handling I wiring diagramm I applikation I DALI MCU digital rotary dimmer Application example with 4 operation points 230V/ 50Hz 300m cable length 50 DALI ECG by 2nd DALI MCU (at mains supply) Up to 4 operation points DALI MCU | Seite 13 general I handling I wiring diagramm I applikation I DALI MCU digital rotary dimmer Application example with 4 operation points 230V/ 50Hz 300m cable length 100 DALI ECG by 4 DALI MCU (at mains supply) Up to 4 operation points DALI MCU | Seite 14 general I handling I wiring diagramm I applikation I DALI MCU digital rotary dimmer Application example with flexible partition wall Priciple: • Partition wall closed, limit switch open • Discrete rooms, operation seperately DALI MCU | Seite 15 general I handling I wiring diagramm I applikation I DALI MCU digital rotary dimmer Application example with flexible partition wall Principle: • Partition wall open, limit switch closed • Connected room with 2 operation points DALI MCU | Seite 16 general I handling I wiring diagramm I applikation I DALI MCU digital rotary dimmer Additional informations: www.osram.com/ecg-lms www.osram.com/systemguarantee We wish you a great sucess with the DALI MCU DALI MCU | Seite 17