HF-M Blue Electronic ballasts for f luorescent lamps Product Description • Compact light weight, high-frequency cold • Fixing centers for mounting remain same as equivalent electromagnetic ballasts start CE compliant electronic ballasts for TL (13-18W), TL5 (14-24W) and compact Applications fluorescent PL (10-28W) lamps. • HF-M Blue ballasts are designed for areas where the lighting is switched on and off Features and Benefits • Instant start flicker-free starting, ideal for lighting applications with long burning hours and infrequent switching for optimum lamp infrequently • HF-M Blue should not be used in combination with movement/ presence datection • Typical areas of application in indoor life. It is advisable to use HF-M Blue ballasts residential situations indude living rooms where the lighting is burning continuously for kitchens (under cupboards), studies at least 3 hours (3-8 switching per day), or in (desktop), bedrooms, halls, staircases and residential applications where the intensity of garages use is limited • Energy savings of more than 25% (at equal • Typical outdoor residential situations include driveways, porches front doors and galleries luminous flux) compared with electromag- • Suitable for DC operations netic gear • For luminaires with protension class I and II • Multi-lamp ballast one type can be used to drive a single lamp of different types and can meet EMC requirement if follow the assembly instructions wattages, e.g. a TL mini 13W, or a PL-S 11W or a PL-C 10/13W or a PL-Q 16W or a TL5 Quality HE 14W lamp can be connected to the This implies optimum quality regarding HF-M Blue 114 SH TL/ PL-S/ PL-C 220-240V • System supplier ballast • Compact dimensions and low weight As manufacturers of lamps and electronic control gear, Philips makes sure that, from compared to electromagnetic ballasts that the earliest development stage, optimum this design replaces lamp/ballast performance is achieved. Compliances and approvals • RFI<300MHz EN 55015 ed7.1 • Harmonics IEC 61000-3-2 • Safety IEC 61347-2-3 • Vibration & bump tests IEC 68-2-6 FC C1 ISO 9001 • Environmental standard ISO 14001 • Certificates KEMA-KEUR A1 A1 B1 B1 D1 D1 A2 IEC 68-2-29 Eb • Quality standard C1 C2 A2 HF-M Blue LH HF-M Blue SH CE Type A1 A2 B1 C1 C2 D1 HF-M Blue 114 SH TL/PL-S/PL-C 220-240V 80 70 40 22 10 4.4 HF-M Blue 121 LH TL5 220-240V 187 176 22 22 - 4.4 HF-M Blue 124 LH TL/TL5/PL-L 220-240V 187 176 22 22 - 4.4 HF-M Blue 126 LH PL-Q/PL-C/PL-T 220-240V 144 132 22 22 - 4.4 HF-M Blue 124 SH TL/TL5/PL-L 220-240V 94 84 40 22 10 4.4 HF-M Blue 118 SH PL-C/PL-T 220-240V 80 70 40 22 10 4.4 Technical data Type Rated input power (1) HF-M Blue 114 SH TL/PL-S/PL-C 220-240V 11-14 Rated Lamptype Line voltage Line Frequency Battery voltage lamp ignition Mains voltage safety (AC) TL mini 13W; TL5 HE 14W; PL-S 11W; PL-C 10/13W; PL-Q 16W 220-240V 50/60Hz 194-254V 198-264V (W) HF-M Blue 121 LH TL5 220-240V 21 TL5 HE 21W 220-240V 50/60Hz 194-254V 198-264V HF-M Blue 124 LH TL/TL5/PL-L 220-240V 17-23 TLD 15/18W; TL5 HO 24W; TL5C 22W; PL-L 18/24W 220-240V 50/60Hz 194-254V 198-264V HF-M Blue 126 LH PL-Q/PL-C/PL-T 220-240V 21-24 PL-Q 28W; PL-C 26W; PL-T 26W 220-240V 50/60Hz 194-254V 198-264V HF-M Blue 124 SH TL/TL5/PL-L 220-240V 17-23 TLD 15/18W; TL5 HO 24W; TL5C 22W; PL-L 18/24W 220-240V 50/60Hz 194-254V 198-264V HF-M Blue 118 SH PL-C/PL-T 220-240V 18 PL-C 18W; PL-T 18W 220-240V 50/60Hz 194-254V 198-264V (1) Depending on lamp combination Type Power Factor Power Maximum Colour Colour Conn.type Conn.type 100% output losses ighition input output input output power gear time terminals terminals terminals terminals HF-M Blue 114 SH TL/PL-S/PL-C 220-240V 0.6 - [nom] 1.7-2.3W 0.5 s [max] Grey Grey Insert Insert HF-M Blue 121 LH TL5 220-240V 0.6 - [nom] 1.7-2.6W 0.5 s [max] Grey Grey Insert Insert (1) HF-M Blue 124 LH TL/TL5/PL-L 220-240V 0.6 - [nom] 2.5W 0.5 s [max] Orange Grey Insert Insert HF-M Blue 126 LH PL-Q/PL-C/PL-T 220-240V 0.6 - [nom] 2.5-3.0W 0.5 s [max] Blue Grey Insert Insert HF-M Blue 124 SH TL/TL5/PL-L 220-240V 0.6 - [nom] 1.7-2.6W 0.5 s [max] Orange Grey Insert Insert HF-M Blue 118 SH PL-C/PL-T 220-240V 0.6 - [nom] 2.5W 0.5 s [max] Orange Grey Insert Insert (1) Depending on lamp combination Mains current Type Input current A HF-M Blue 114 SH TL/PL-S/PL-C 220-240V 0.09-0.12 Mains frequency 50/60 Hz Power factor 0.6 Earth leakage current NA Ignition time < 0.5 s Over voltage protection 48 hrs at 276 V AC HF-M Blue 124 LH TL/TL5/PL-L 220-240V 0.13-0.16 Dual fixture NA HF-M Blue 126 LH PL-Q/PL-C/PL-T 220-240V 0.15-0.18 Cable capacity Max. 120 pF between lamp wires HF-M Blue 124 SH TL/TL5/PL-L 220-240V 0.13-0.16 HF-M Blue 121 LH TL5 220-240V 0.15 HF-M Blue 118 SH PL-C/PL-T 220-240V 0.13 and earth Automatic restart after No, manual restart request lamp replacement Insulation resistance test Inrush current Type 500 V DC from Line/Neutral to Earth (not between Line and Neutral) Max. quantity of ballast per Miniature Circuit Breaker 16A HF-M Blue 114 SH TL/PL-S/PL-C 220-240V HF-M Blue 121 LH TL5 220-240V 100 60 HF-M Blue 124 LH TL/TL5/PL-L 220-240V 60 HF-M Blue 126 LH PL-Q/PL-C/PL-T 220-240V 60 HF-M Blue 124 SH TL/TL5/PL-L 220-240V HF-M Blue 118 SH PL-C/PL-T 220-240V 60 100 Notes: 1. Ensure that the neutral is reconnected again after above mentioned test is carried out and before the installation is put into operation. Electrical installation notes Mains operation Rated mains voltage 220-240 V With tolerances for safety +/- 10% 198-264 V With tolerance for ignition & burning: +5%, -15% 184 - 253 V Technical data for design and mounting HF-M Blue ballasts Connector types: in fixtures Connection wiring is greatly simplified by the use of insert contacts with Temperatures push buttons. Temperature range to ignite lamp -10ºC to +40ºC with ignition aid Wire lenghts: Max. Tcase 75ºC After finishing system installation, please check carefully before you turn the power on. Lifetime of a ballast depends on the temperature of the ballast. This 1. Check whether lamp, ballast model and wiring are compatible means there is a relation between the Tc point on the ballast and its according to Philips HF-M Blue datasheet. lifetime. 2. Keep wires to terminals 1, 2 short. The HF-M Blue ballast has a specified lifetime of 30,000 hrs, with a 3. Mismatch of the ballast and lamp may lead to ballast failure. maximum of 10% failures guaranteed, at a measured Tcase of 75°C . Wire cross-section: Independent lamp operation function NA Hum and noise level On the mains side 0.5 ...1.5 mm2 On the lamp side 0.5 ...1.5 mm2 Strip length 7.5 - 8.5 mm < 30dB at 1m distance Permitted humidity is tested according to IEC 61347-2-3 par.11. Note that no moisture or condensation may enter the ballast. Notes: 1. Data is based on a mains supply with an impedance of 400mΩ, under worst case conditions. With an impedance of 800mΩ the number of ballasts can be increased by 10%. 2. Measurements will be verified in real installations; therefore data are L N HF-M Blue Ballast subject to change. 1 2 3 4 3. In some cases the maximum number of ballasts is not determined by the MCB but by the maximum electrical load of the lighting installation. 4. Note that the maximum number of ballasts is given when these are all switched on at the same moment, i.e. by a wall switch. 5. Measurements were carried out on single-pole MCB’s. For multi-pole MCB’s, it is advised to reduce the number of ballasts by 20%. Ordering and packing data Type Net weight Qty bulk Dimensions Ordering Number Gross weight Pallet packing per piece packing bulk packing per carton box kg pcs cm kg carton / ballast pcs HF-M Blue 114 SH TL /PL-S/PL-C 220-240V 0.048 50 21.5 x 17.5 x 13.0 9137 130 353 3.1 200/10000 HF-M Blue 121 LH TL5 220-240V 0.058 50 23.0 x 20.0 x 13.0 9137 130 352 3.6 200/10000 HF-M Blue 124 LH TL /TL5/PL-L 220-240V 0.058 50 23.0 x 20.0 x 13.0 9137 130 350 3.6 200/10000 HF-M Blue 126 LH PL-Q/PL-C/PL-T 220-240V 0.052 50 23.0 x 16.0 x 13.0 9137 130 354 3.3 240/12000 HF-M Blue 124 SH TL /TL5/PL-L 220-240V 0.052 50 21.1 x 19.8 x 13.0 9137 130 351 3.3 200/10000 HF-M Blue 118 SH PL-C/PL-T 220-240V 0.048 50 21.5 x 17.5 x 13.0 9137 130 349 3.1 200/10000