Form10/00 UK ABWR Document ID Document Number Revision Number : : : GA10-9101-0101-15006 ES-GD-B010 B UK ABWR Generic Design Assessment Generic PCSR Sub-chapter 15.6 : Panel and Raceway Layout Hitachi-GE Nuclear Energy, Ltd. NOT PROTECTIVELY MARKED Form01/03 UK ABWR Page ii/ii DISCLAIMERS Proprietary Information This document contains proprietary information of Hitachi-GE Nuclear Energy, Ltd. (Hitachi-GE), its suppliers and subcontractors. This document and the information it contains shall not, in whole or in part, be used for any purpose other than for the Generic Design Assessment (GDA) of Hitachi-GE’s UK ABWR. This notice shall be included on any complete or partial reproduction of this document or the information it contains. Copyright No part of this document may be reproduced in any form, without the prior written permission of Hitachi-GE Nuclear Energy, Ltd. Copyright (C) 2015 Hitachi-GE Nuclear Energy, Ltd. All Rights Reserved. GA91-9101-0101-15006 Rev. B NOT PROTECTIVELY MARKED NOT PROTECTIVELY MARKED Form05/01 Generic Pre-Construction Safety Report UK ABWR Revision B Table of Contents 15.6.1 Requirements for Panels and Raceway Layout .......................................15.6-1 15.6.2 References ....................................................................................................15.6-1 15. Electrical Power Supplies 15.6 Panel and Raceway Layout: Table of Contents Ver.0 NOT PROTECTIVELY MARKED i NOT PROTECTIVELY MARKED Form05/01 Generic Pre-Construction Safety Report UK ABWR Revision B 15.6.1 Requirements for Panels and Raceway Layout The following key requirements / principles apply to electrical and C&I panels and cable raceway design: Further details of requirements, separation distances, installation patterns and layout are contained in [Ref-2]. Safety Class 1 electrical panels, circuits and raceways of trays and conduits are designed to be physically and electrically separated from those of the other safety classes (Class 2/3) and nonsafety class. Class 1 electrical panels are physically separated between safety divisions by walls, floors, ceilings, distance or barriers. Safety class 1 electrical panels are also physically separated from panels of the other safety classes (class 2/3) using the same methods. Further details are explained in [Ref-2]. Class 1 circuits are electrically separated between safety divisions by isolators. Safety class 1 circuits are also electrically separated from circuits of the other safety classes (class2/3) and non- safety class by isolators. Class 1 raceways (trays and conduits) are also physically separated between safety divisions by walls, floors distance or barriers. Safety class 1 electrical raceways are also physically separated from raceways of other safety classes (class 2/3) and non-safety class by the same methods. Class 1 electrical equipment is qualified for seismic activity and LOCA Safety class electrical equipment is shielded from non- safety class equipment to minimise electromagnetic interference (EMI). Panels, circuits and raceways of the other safety classes (class 2 and class 3) are routed together with with those of non-safety class. Class 1 cable arrangements will pass vertical tray flame tests to confirm flame propagation performance. Openings for trays and conduits which penetrate walls and floors between different safety divisions will be sealed to prevent propagation of fires. 15.6.2 References [Ref-1] Hitachi-GE Nuclear Energy, Ltd. :”Electrical Equipment and Raceway Separation Plan” (GA33-1001-0001-00001(ES-GD-B001), Rev.0) (To be issued in GDA Step-4) [Ref-2] Hitachi-GE Nuclear Energy, Ltd.:”Topic Report for Electrical Installation ” (GA91-920100126(EE-GD-B008) Rev.0) (To be issued in GDA Step-4) 15. Electrical Power Supplies 15.6 Panel and Raceway Layout Ver. 0 15.6-1 NOT PROTECTIVELY MARKED