R-78xx-1.0 - RECOM Power

advertisement
v
Features
●
●
●
●
●
●
●
Efficiency up to 94%, no need for heatsinks!
Pin-out compatible with LM78XX Linear Regs.
Low profile (L*W*H=11.5*7.5*10.2mm)
Wide input range (4.75V ~ 18V)
Short circuit protection, thermal shutdown
Non-standard outputs available as specials
Low ripple and noise
INNOLINE
DC/DC-Converter
with 3 year Warranty
Description
1.0 AMP
SIP3
Single Output
The R-78xx-1.0 series switching regulators are ideally suited to replace 1 Amp 78xx linear regulators and are pin
compatible. Efficiencies of up to 97% means that very little energy is wasted as heat so there is no need for any
heat sinks with their additional space and mounting costs.
Selection Guide
Part
Number
SIP3
R-781.8-1.0
R-782.5-1.0
R-783.3-1.0
R-785.0-1.0
Input
Range
(V)
4.75 – 18
4.75 – 18
4.75 – 18
6.5 – 18
Output
Voltage
(V)
1.8
2.5
3.3
5.0
Output
Current
(A)
1.0
1.0
1.0
1.0
Efficiency
Min. Vin
Max. Vin
(%)
(%)
82
76
87
81
90
84
94
89
Specifications ( typical at 25°C, 10% minimum load, unless otherwise specified )
RoHS
2011/65/EU
6/6
EN-55022 Certified
EN-55024 Certified
IEC/EN-60950-1 Certified
R-78-1.0
Derating-Graph
(Ambient Temperature)
120
100
Output Power (%)
Characteristics
Conditions
Min.
Typ.
Max.
Input Voltage Range
All Series
4.75V
18V
Output Voltage Range
All Series
1.5V
5.5V
Output Current
All Series
0mA*
1000mA
Short Circuit Input Current (Vin =12V)
All Series
100mA
Internal Power Dissipation
0.4W
Short Circuit Protection
Continuous, automatic recovery
Output Voltage Accuracy (At 100% Load) All Series
±2%
±3%
Line Regulation (100% Load, Vin max.)
All Series
0.2%
0.4%
Load Regulation (10 to 100% full load)
All Series
0.4%
0.6%
Dynamic Load Stability
100% <-> 50% load
±85mV ±100mV
Ripple & Noise (20Mhz BW)
All Series
20mVp-p 30mVp-p
Temperature Coefficient
-40°C ~ +85°C ambient
0.015%/°C
Max capacitance Load with normal start-up time, no external components
470µF
with <1 second start up time + diode protection circuit
6800µF
Switching Frequency
280kHz
350kHz
430kHz
Quiescent Current
Vin = min. to max. at 0% load
5mA
7mA
Operating Temperature Range
-40°C to +85°C
Operating Case Temperature (with derating)
+100°C
Storage Temperature Range
-55°C to +125°C
Case Thermal Impedance
70°C/W
Case Material
Non-Conductive Black Plastic
Potting Material
Silicone (UL94V-0)
Conducted Emissions (with filter)
EN55022
Class B
Radiated Emissions (with filter)
EN55022
Class B
ESD
EN61000-4-2
Class A
Radiated Immunity
EN61000-4-3
Class A
Fast Transient
EN61000-4-4
Class A
Conducted Immunity
EN61000-4-6
Class A
Magnetic Field Immunity
EN61000-4-8
Class A
Certifications
IEC/EN General Safety
Report: LVD 1603123
IEC/EN-60950-1, 2nd Edition + AM:2
EMC
Report: 5A111502E
EN 55022, EN55024, EN61000
Package Weight
1.9g
Packing Quantity
42 pcs per Tube
MTBF (+25°C)
using MIL-HDBK 217F
13338 x 10³ hours.
Detailed Information see
(+71°C) Application Notes chapter "MTBF"
using MIL-HDBK 217F
3880 x 10³ hours.
80
60
40
30
20
0
-40
Safe Operating Area
0
25
50
Operating Temperature (°C)
60
85
75 100
}
I-12
REV: 1/2016
www.recom-power.com
R-78xx-1.0
Series
INNOLINE
DC/DC-Converter
Characteristics
Ripple
Efficiency
100
50
Vo=5V
Vo=3.3V
Vo=2.5V
Vo=1.8V
75
Vo=5V
25
Vo=3.3V
Vo=2.5V
Vo=1.8V
Ripple (mV)
Efficiency (%)
50
25
5
15
10
18
5
Vin ( V )
Ripple Vs Vin ( Full Load )
100
50
Vo=5V
Vo=3.3V
Vo=2.5V
Vo=1.8V
75
Vo=5V
25
25
0.2
0.4
0.6
0.8
1.0
0.2
1.2
0.4
0.6
0.8
1.0
R-78-1.0
Vo=3.3V
Vo=2.5V
Vo=1.8V
Ripple (mV)
50
Efficiency (%)
18
Vin ( V )
Efficiency Vs Vin (Full Load)
1.2
Output Current ( A )
Output Current ( A )
Ripple Vs Load ( Vin=Max )
Efficiency Vs Load ( Vin=Max )
100
50
Vo=5V
Vo=3.3V
Vo=2.5V
Vo=1.8V
75
50
25
Vo=5V
Vo=3.3V
Vo=2.5V
Vo=1.8V
Ripple (mV)
Efficiency (%)
15
10
25
0.2
0.4
0.6
0.8
1.0
1.2
0.2
Output Current ( A )
0.4
0.6
0.8
1.0
1.2
Output Current ( A )
Efficiency Vs Load ( Vin=Min )
Ripple Vs Load ( Vin=Min )
*Note: Operation under no load will not damage these devices, however they may not meet all specifications. A minimum load of 10mA is recommended
www.recom-power.com
REV: 1/2016
I-13
R-78xx-1.0
Series
INNOLINE
DC/DC-Converter
Optional Protection Circuit
Optional Protection 1:
Add a blocking diode to Vout if
current can flow backwards into
the output, as this can damage
the converter when it is powered
down.
+Vin
Optional Protection 2:
+Vin
+Vout
R-78xx-xx
Vout=
+Vout 0.3V
R-78xx-xx
The diode can either be fitted
across the device if the source is
low impedance or fitted in series
with the output (recommended).
Schottky Diode
GND
GND
GND
GND
Application Examples
High efficiency, isolated, dual regulated outputs
REC3-0515DRW/H4
+15VDC
R-785.0-1.0
+Vin
Com
C1
GND
C2
- Medical Grade Isolated Dual Outputs
GND
C1: Optional , C2 : Required (further decoupling filtering
may be necessary between the two converters)
- Wide input range 6.5V to 18V
- High Efficiency, Suitable for 12V Battery Powered Devices
Isolated (up to 6KV), wide Input range regulated output
DC/DC Converter ( 1:1 )
R-78-1.0
+Vin
R-78xx-1.0
+Vout
C1
GND
C2
- High isolation voltage
- Improved loading / line regulation
- Wide Input Voltage Range
- Point-of-Load Architecture
GND
C1 , C2 : optional
Package Style and Pinning (mm)
SIP3 PIN Package
7.55
10.2
RECOM
R-785.0-1.0
0.51 typ.
**** Pb
Front
1 2 3
0.7 ±0.1
4.10
Recommended Footprint Details
1.00 ø+0.15/–0
11.50
0.25
Bottom View
3.21
5.08
RECOM
R-785.0-1.0
**** Pb
2.54
2.0
Top View
2.54
Pin Connections
Pin #
1
2
3
xx.x ±0.5mm
xx.xx ±0.25mm
+Vin
GND
+Vout
The product information and specifications are subject to change without prior notice. RECOM products are not authorized for use in safety-critical applications (such as life support) without RECOM’s explicit
written consent. A safety-critical application is defined as an application where a failure of a RECOM product may reasonably be expected to endanger or cause loss of life, inflict bodily harm or damage property. The buyer
shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the unauthorized use of RECOM products in such safety-critical applications.
I-14
REV: 1/2016
www.recom-power.com
Download