1P Plugs and Receptacles Industrial Heavy Duty Non-Hazardous Description Page No. Application/Selection 964, 965 Arktite® Series Technical Data Aluminum AR/APJ Style 20A 30A 60A 100A 200A 400A Configured Arktite® ARC/APJC Style Technical Data 30, 60, 100A Back Boxes Krydon® NR/NPJ Style Technical Data 30, 60, 100A Flanged Panel Mount Motor Plugs US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds Malux Finland Oy, P.O.Box 69, FI-06151 PORVOO, FINLAND phone: +358 19 5745 700, fax: +358 19 5745 750, e-mail: info@malux.fi, web: www.malux.fi 966-969 970 972, 973 974, 975 976, 977 978-980 981, 982 986, 987 988, 989 990, 993 983 984, 985 994, 995 996, 997 963 1P Plugs and Receptacles Industrial Heavy Duty Application and Selection Application: ɀ Distribution of secondary electrical power ɀ Provide quick disconnect from power source Considerations for Selection: Options: Electrical System: ɀ Amperage and voltage required for application Wiring system and number of conductors required. See page 969 for contact sizes. Compatibility with System: ɀ Need for interchangeability with plugs in existing system and within parts of new system. Grounding styles. Two styles utilized. See page 967 for complete description to determine which is suitable for needs. Mounting Arrangement: ɀ Three types of mounting available – surface, flush and panel Application: ɀ Fixed receptacle for power outlet; cable connectors for portable cable extensions Other Considerations: ɀ Wire sizes and recess dimensions available. See page 969 for complete details. National Electrical Code, UL, NEMA, Canadian Electrical Code, CSA compliances ɀ Environment – need for operation in harsh, dirty or corrosive conditions. ɀ Special polarity arrangements available as well as special back boxes and hub arrangements. See listing pages for details. Quick Selector Chart Electrical Characteristics No. of Poles (Range) Grounding Style† Mounting Mating Plug 600VAC 250VDC 2-5 1-2 APJ, NPJ, APQ, AP 30, 60, 100 600VAC 250VDC 3-5 2 APJC, APQC Fixed 20, 30, 60, 100, 200, 400 600VAC 250VDC 2-5 1-2 Back box (surface) APJ, NPJ, AP ARC Fixed 30, 60, 100 600VAC 250VDC 3-5 2 Back box (surface) APJC AR Fixed 30, 60, 100, 200 600VAC 250VDC 2-4 1-2 Panel mtg. (semi-flush) APJ, NPJ, AP NPR Portable cable 30, 60, 100 600VAC 250VDC 3-4 2 NR Fixed 30, 60, 100 600VAC 250VDC 3-4 2 Receptacle Series Receptacle Type Amperage (Range) Volts (Max.) APR Portable cable 20, 30, 60, 100, 200, 400 APRC Portable cable AR NPQ, APJ, NPJ (fixed) Back box (surface) † See page 967 for detailed explanation. 964 US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds Malux Finland Oy, P.O.Box 69, FI-06151 PORVOO, FINLAND phone: +358 19 5745 700, fax: +358 19 5745 750, e-mail: info@malux.fi, web: www.malux.fi APJ, NPJ 1P Plugs and Receptacles Industrial Heavy Duty Interchangeability Chart Interchangeability Chart Many of the plugs listed in this section can be used interchangeably with receptacles from other sections, both in hazardous and nonhazardous areas, provided electrical rating and style of plug and receptacle are the same. The following table is a summary of possible combinations. Plugs Shown in Section 1P Can be Used with These Receptacle Series Listed in Section APJ, NPJ* DR 2P 30, 60 amp. 2-wire, 2-pole 3-wire, 3-pole 4-wire, 4-pole 2-wire, 3-pole 3-wire, 4-pole DBR 3P 30, 60, 100 amp. 3-wire, 3-pole 3-wire, 4-pole FSQ 4P 30 amp. 2-wire, 3-pole 3-wire, 4-pole EPC, EPCB, EBBR 4P 30, 60, 100 amp. 2-wire, 3-pole 3-wire, 4-pole NBR, NSR 3P 30, 60, 100 amp. 3-wire, 3-pole 3-wire, 4-pole WSR 3P 30, 60, 100 amp. 3-wire, 3-pole 3-wire, 4-pole WSRD 3P 60 amp. 3-wire, 3-pole 3-wire, 4-pole AR, NR*, NPR* 1P 30 and 60 amp. 2-wire, 3-pole DR, CES, CESD 2P FSQ, EPC, EPCB, DBR 4P DBR, NBR, NSR, WSR, WSRD 3P CPH Plugs & Receptacle Electrical Rating 30 and 60 amp. 3-wire, 4-pole * NPJ, NR and NPR available in 2-wire, 3-pole and 3-wire, 4-pole electrical ratings only. US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds Malux Finland Oy, P.O.Box 69, FI-06151 PORVOO, FINLAND phone: +358 19 5745 700, fax: +358 19 5745 750, e-mail: info@malux.fi, web: www.malux.fi 965 1P Arktite® Heavy Duty Circuit Breaking Plugs and Receptacles NEMA 4 Watertight Industrial Heavy Duty Non-Hazardous Areas illustrated here, is for conditions where it is desired to use the contact of the plug sleeve with the detent spring to complete the grounding safety circuit. The extra grounding conductor in the portable cable is connected to the plug sleeve by a pressure connector.) Each plug contact fits closely the opening of its individual arcing chamber. Grounding contact is bonded to the plug sleeve. Grounding contact is keyed to its proper location to prevent mispolarization. Arktite connectors’ gasketing system provides unsurpassed watertight integrity. All-aluminum UNI-SHELL TM threaded construction provides added strength to withstand extreme physical abuse. Application: Arktite circuit breaking plugs and receptacles are used: ɀ to supply power to portable electrically operated devices such as motor-generator sets, compressors, heating and cooling units, welders, conveyors, lighting systems and similar equipment ɀ where temporary power is needed, such as at trailers, building units, heavy machinery and similar equipment ɀ wherever electrical loads must be quickly disconnected from power source ɀ in a typical installation, where a large machine utilizes a number of electrical motor drives and for ease of adjustment, removal, maintenance and replacement, each motor is connected by portable cord and Arktite receptacles rather than permanently wired ɀ in areas where dust, dirt, moisture and corrosion are a problem ɀ indoors and outdoors in non-hazardous areas of chemical plants, process industry facilities, meat packing plants, manufacturing plants and similar industrial locations NEW! NEMA 4 Rating Features: ɀ Circuit breaking: Plugs through 200 ampere rating may be disconnected under load; 400 ampere units are for service disconnect use only. ɀ Receptacles accept only plugs of the same amperage rating, style and number of poles, making it impossible to mismate, and provides for positive polarization. ɀ Extra wide electrical spacing allows for maximum safety. ɀ Insulator materials are the result of intensive testing. Selection has been made based on highest dielectric strength, maximum mechanical and impact resistance, lowest moisture absorption and highest arc tracking resistance. ɀ A variety of installations is possible due to the availability of several types of back boxes. ɀ Designed to withstand rough usage and the effects of adverse environments. ɀ Reversible interiors, 30, 60 and 100 ampere (except 30 and 60 ampere, 5-pole) Arktite plug and receptacle interiors are interchangeable using a screwdriver. This makes it possible to feed a normally deenergized receptacle from an energized plug with usual Arktite safety; no energized contacts are exposed. ɀ Additional features are indicated in the view at right: Grounding contact in Style 2 is bonded to the receptacle housing. Easily wired interior assemblies in receptacles and plugs. See table on page 938 for type of contacts in units. Arktite Style 2, illustrated here, has an extra grounding contact which forms a parallel circuit with the circuit formed by the plug sleeve and receptacle detent spring, and assures continuity of the grounding 966 Arktite Style 2 60 ampere NEW! Smaller Cable Range safety circuit under severe service. Grounding contact is no longer than the others, so grounding circuit is made first and broken last. The arc formed by pulling the plug is instantly snuffed in the deep, confined insulated arcing chamber while the plug contact is still a considerable distance inside. The arc cannot travel over to the other side of the circuit or to the housing. Detent spring forms a grounding path from plug sleeve to receptacle housing. Arktite plugs and receptacles are made in two styles. With either style, the portable appliance is grounded before it is energized and remains grounded until after it is deenergized. (Arktite Style 1, not US: 1-866-764-5454 CAN: 1-800-265-0502 Arktite’s TRI-LOCK TM cable grip has three clamps that tighten around the cable to securely lock it in place, even when subjected to extreme flexing and jerking. The unique SURE-SEAL TM cable gland provides a complete environmental seal by distributing pressure equally around the circumference of the cable. Wrenching surfaces make Arktite connector quick and easy to assemble. Copyright© 2006 Cooper Crouse-Hinds Malux Finland Oy, P.O.Box 69, FI-06151 PORVOO, FINLAND phone: +358 19 5745 700, fax: +358 19 5745 750, e-mail: info@malux.fi, web: www.malux.fi Arktite® Heavy Duty Circuit Breaking Plugs and Receptacles 1P NEMA 4 Watertight Industrial Heavy Duty Non-Hazardous Areas Grounding: Style 1 vs. Style 2 Cooper Crouse-Hinds Arktite devices utilize two methods, or styles, for completing the grounding circuit in plugs and receptacles. NEC reference 250.138 (A) & (B). Style 1 – Metallic STYLE 2 – Metallic Style 2 – Non-Metallic A Style 1 plug is one in which the grounding conductor in the flexible cable is bonded to the plug sleeve by a pressure connector. A Style 1 receptacle is one which is grounded by virtue of the fact that it is an integral part of a grounded conduit system. On insertion, the plug sleeve makes contact with detent springs of the grounded receptacle housing before line and load poles engage, and on withdrawal, remains in contact until after line and load poles disengage. Therefore, exposed metal parts of the portable equipment or plug are suitably grounded. A Style 2 metallic housing plug is one in which the grounding conductor in the flexible cable is bonded to the extra (grounding) pole and metal plug sleeve by a pressure connector. A Style 2 metallic housing receptacle is one in which the extra (grounding) pole is electrically connected to the equipment grounding conductor and the metal receptacle housing which itself is grounded by virtue of the fact that it is an integral part of a grounded conduit system. In Style 2, non-metallic housing plugs and receptacles, the extra pole is used for grounding since the housings are nonconductive. In a Style 2 receptacle, the grounding connection is made before line and load poles engage, and is broken after the line load poles disengage. Furthermore, upon insertion, the plug sleeve of metal shelled units, makes contact with detent springs of the grounded receptacle housing before line and load poles engage, and on withdrawal, remains in contact until after line and load poles disengage. Therefore, exposed metal parts of the portable equipment or plug are suitably grounded. Made of non-metallic Krydon material Metal shelled type Style 2 Ground conductor attaches to contact, which is bonded to shell. Style 1 Ground conductor attaches to shell. US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds Malux Finland Oy, P.O.Box 69, FI-06151 PORVOO, FINLAND phone: +358 19 5745 700, fax: +358 19 5745 750, e-mail: info@malux.fi, web: www.malux.fi 967 1P Arktite® Heavy Duty Circuit Breaking§ Plugs and Receptacles NEMA 4 Watertight Industrial Heavy Duty Non-Hazardous Areas Options: ɀ The following special options are available from factory by adding suffix to Cat. No.: Suffix to be Added to Cat. # Description S22. . . . .Reversed contacts. Receptacle assembled with plug interior (exposed contacts), plug assembled with receptacle interior (recessed contacts). For applications where plug is energized to feed normally deenergized receptacle. Available on 30 through 400 ampere units NOTE: 30 (2, 3, 4-pole), 60 and 100 ampere interiors can be interchanged in the field using a screwdriver. Factory conversion is required for 200 and 400 ampere products. S4. . . . . .Special polarity. For use where two or more receptacles of the same ampere rating, style and number of poles are to be installed in the same area for use on different voltages and/or frequencies. Prevents insertion of a plug in a receptacle with different electrical rating. Available on 20 through 400 ampere units as follows: Receptacle interior rotated 221⁄2 degrees to right and plug changed to match (See photo to right) Arktite receptacles have a cast raised rib located inside the receptacle sleeve. The location of the rib is in a specific relationship to the receptacle insulator that houses the contacts. The mating plug has a cast groove located on the outside of the plug sleeve. This groove lines up with the raised rib. Standard Materials: ɀ Metallic receptacle housings, plug and cord connector bodies – high impact strength copper-free aluminum ɀ Nonmetallic receptacles, plugs and cord connectors – Krydon® fiberglass-reinforced polyester material ɀ Back boxes: 20, 30, 60, 100 and 200 ampere – cast aluminum; 400 ampere – Feraloy® iron alloy ɀ Insulation (metallic products): (2-, 3-, and 4-pole) 30, 60, 100, 200, 400 ampere – fiberglass-reinforced polyester; 20, 30 ampere (5-pole) – melamine ɀ Contacts: pressure, solder, binding screw – brass; crimp/solder – leaded red brass; 20, 30, 60, 100 ampere – telurium copper; 200, 400 ampere Accessories: Accessories include a variety of angle adapters, panel adapters and back boxes for Arktite receptacles, listed on pages 990-993. Included throughout 1P are wire mesh cable grips and protective caps for Arktite plugs. Certifications and Compliances: ɀ UL Standards: 1682, 514; 1010 (APJ and NPJ plugs only) ɀ CSA Standard: C22.2 No. 182.1 Typical installation Standard Finishes: ɀ Feraloy—electrogalvanized and aluminum acrylic paint ɀ Aluminum – natural ɀ Krydon fiberglass-reinforced polyester material – grey ɀ Fiberglass-reinforced polyester insulation – (red) ɀ Melamine – natural (brown) ɀ Brass – natural ɀ Leaded red brass – electro-tin-plate § 400A rated units are for service disconnect use only. 968 US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds Malux Finland Oy, P.O.Box 69, FI-06151 PORVOO, FINLAND phone: +358 19 5745 700, fax: +358 19 5745 750, e-mail: info@malux.fi, web: www.malux.fi Arktite® Heavy Duty Circuit Breaking§ Plugs and Receptacles 1P NEMA 4 Watertight Industrial Heavy Duty Non-Hazardous Areas Arktite Horsepower Ratings ɀ Locked-Rotor Interrupting Electrical System Single-phase Three-phase ɀ Emergency Interrupting Ampere Rating Plug and Receptacle 30 60 100 200 Motor Horsepower† 120 240 480 Volts Volts Volts 2 3 7.5 5 10 25 10 20 15 40 600 Volts 10 20 30 60 100 200 3 10 15 30 10 50 25 15 5 20 30 60 10 40 40 25 Electrical System Single-phase Three-phase Ampere Rating Plug and Receptacle 30 60 100 200 H.P. Rating 120 240 Volts Volts 2 3 5 10 7.5 20 15 40 480 Volts 10 25 30 40 600 Volts 10 20 30 40 30 60 100 200 3 10 10 20 15 40 40 50 20 50 40 50 7.5 20 30 60 Wire Sizes: The table below lists the diameter of the wire recess in Arktite plug and receptacle contacts so that maximum size of bare conductor can be figured. Range of wire sizes shown in table is intended only as a guide. Depending on type of wire used (building wire, flexible or extra flexible cable) and its construction (number and size of strands), bare copper diameters vary widely. Diameter of Wire Recess in Plug and Receptacle Contacts Ampere Rating 20 30 (2, 3, & 4-pole) 30 (2, 3, & 4-pole) 30 (5-pole) 60 (2, 3, 4 & 5-pole) 60 (3 & 4-pole) 100 (2, 3 & 4-pole) 100 (3 & 4-pole) 200 (Std. 3 & 4-pole) 200 (Lg. 3 & 4-pole) 400 (Std. 3 & 4-pole) 400 (Lg. 3 & 4-pole) Contact Type Binding Screw Pressure Crimp/Solder Solder Pressure Crimp/Solder Pressure Crimp/Solder Crimp/Solder Crimp/Solder Crimp/Solder Crimp/Solder Diameter of Recess N/A .281 .180 .188 .312 .277 .390 .390 .56 .75 .84 1.25 Wire Size‡ Building #14-#12 #10-#6 #10-#8** #12-#6 #6-#4 #6-#4** #4-#1 #2-#1** #1-4/0 4/0-250MCM 250-500MCM 500-1000MCM Extra Flex #14-#12 #10-#8 #10-#8 #12-#8 #8-#4 #8-#4 #4-#2 #2-#2 #1-3/0 3/0-250MCM 250-400MCM 400-750MCM ** Smaller sizes may be used with well reducers – information on request. † Horsepower ratings are based on Cooper Crouse-Hinds testing in which locked-rotor currents were interrupted by withdrawing the plug from the receptacle. It is highly recommended, however, that such use be limited to emergency conditions only; and that a horsepower rated switch be used for motor disconnect. ‡ Do not use wire size smaller than minimum size recommended. § 400A rated units are for service disconnect use only. US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds Malux Finland Oy, P.O.Box 69, FI-06151 PORVOO, FINLAND phone: +358 19 5745 700, fax: +358 19 5745 750, e-mail: info@malux.fi, web: www.malux.fi 969 Notes Page 970 US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds Malux Finland Oy, P.O.Box 69, FI-06151 PORVOO, FINLAND phone: +358 19 5745 700, fax: +358 19 5745 750, e-mail: info@malux.fi, web: www.malux.fi Arktite® Heavy Duty Circuit Breaking Receptacles, Plugs and Connectors 1P NEMA 4 Watertight 20 A, 600 VAC/250 VDC, 50**-400 hertz Receptacle with Back Box Config. 2W 2P 2W 2P Hub Size 1⁄2 1⁄2 3⁄4 3⁄4 Descrip. Spring Door Threaded Cap Spring Door Threaded Cap Cat No. # ARE2211 ARE2271 ARE2212 ARE2272 Receptacle Config. 2W 2P Descrip. Spring Door Threaded Cap Cat No. # AR221 AR227 Plug Config. 2W 2P Cable Dia. .250–.500 .250–.500 Descrip. Fastening Ring W/O Fastening Ring Cat No. # APJ2271 APJ2251 2W 2P .500–.875 .500–.875 Fastening Ring W/O Fastening Ring APJ2273 APJ2253 Descrip. Connector Connector Cat No. # APR2251 APR2253 Connector Config. 2W 2P Cable Dia. .250–.500 .500–.850 Dimensions ARE Assembly AR Receptacle - Spring Door AR Receptacle - Open and with cap APJ Plug Hub size a 11⁄16 1⁄2 3⁄4 13⁄16 NOTE: For listing of additional back boxes, see pages 999 and 991. ** For use on systems less than 60 hertz the receptacles, plugs and connectors are for disconnect use only. US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds Malux Finland Oy, P.O.Box 69, FI-06151 PORVOO, FINLAND phone: +358 19 5745 700, fax: +358 19 5745 750, e-mail: info@malux.fi, web: www.malux.fi 971 1P Arktite® Heavy Duty Circuit Breaking Receptacle Assemblies and Housings NEMA 4 Watertight 30 A, 600 VAC/250 VDC, 50**-400 hertz Receptacle Assembly With ARE Back Boxes Style 1 Description Receptacle Housings Only Style 1 Mating APJ Plugs† Style 1 Hub‡ Size Spring Door Cat. # Spring Door Cat. # Threaded Cap Only Cat. # 2-wire, ⎫ 2-pole ⎬⎭ 1⁄2 3⁄4 ARE3211 ARE3212 AR321 AR327 3-wire, ⎫ 3-pole ⎬⎭ 3⁄4 1 ARE3312 ARE3313 AR331 AR337 4-wire, ⎫ 4-pole ⎬⎭ 3⁄4 1 ARE3412 ARE3413 AR341 AR347 5-wire, ⎫ ⎬ 5-pole ⎭ 1 ARE3513 AR351 Style 2 2-wire, ⎫ 3-pole ⎬⎭ Mating Plug Receptacle Style 2 3⁄4 Mating Connector Mating APR Connectors Style 1 Cat. # Cable Dia. Cat. # Cable Dia. APJ3275 0.39 to 1.20 APR3255 0.39 to 1.20 APJ3375 0.39 to 1.20 APR3355 0.39 to 1.20 APJ3475 0.39 to 1.20 APR3455 0.87 to 1.02 APJ3573 .500 to .875 APR3553 .500 to .875 Style 2 1 ARE3322 ARE3323 AR332 AR338 3-wire, ⎫ 4-pole ⎬⎭ 3⁄4 1 ARE3422 ARE3423 AR342 AR348 4-wire, ⎫ ⎬ 5-pole ⎭ 1 ARE3523 AR352 Style 2 APJ3575 .875 to 1.375 APR3555 .875 to 1.375 APJ3485 0.39 to 1.20 APR3465 0.39 to 1.20 APJ3583 APJ3585 .500 to .875 .875 to 1.375 APR3563 APR3565 .500 to .875 .875 to 1.375 Dimensions ARE Assembly AR Receptacle - Spring Door Plug AR Receptacle - Open and with cap Connector ** For use on systems less than 60 hertz the receptacles, plugs and connectors are for disconnect use only. 972 US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds Malux Finland Oy, P.O.Box 69, FI-06151 PORVOO, FINLAND phone: +358 19 5745 700, fax: +358 19 5745 750, e-mail: info@malux.fi, web: www.malux.fi Arktite® Heavy Duty Circuit Breaking Receptacle Assemblies and Housings 1P NEMA 4 Watertight 30 A, 600 VAC/250 VDC, 50**-400 hertz Plug Closure Caps: Application: CPK caps for Arktite plugs are used: ɀ where portable equipment is on a standby basis and plugs are not in use ɀ to effectively protect insulation and contacts from excessive moisture, dirt, dust and corrosion ɀ with 30, 60, 100 and 200 ampere plugs with fastening ring and standard 200 ampere plugs for the clamp door housing Standard Materials: Config. Cat No. # 2P & 3P & 4P 5P CPK13 CPK32 ɀ Copper-free aluminum Standard Finishes: ɀ Natural Replacement Parts: Config. 2W 2P 2W 3P 3W 3P 3W 4P 4W 4P 4W 5P 5W 5P Receptacle Interior ATP275 ATP278 ATP276 ATP279 ATP277 ATP125 ATP94 Plug Interior ATP270 ATP273 ATP271 ATP274 ATP272 ATP109 ATP73 Spring Door Screw Cap QE50 QE13 N/A N/A Recep Plug AR30CONKIT AP30CONKIT Replacement Pin & Sleeve Contacts: Description Available as a kit only. 5 phase contacts & 1 ground contact included ** For use on systems less than 60 hertz the receptacles, plugs and connectors are for disconnect use only. US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds Malux Finland Oy, P.O.Box 69, FI-06151 PORVOO, FINLAND phone: +358 19 5745 700, fax: +358 19 5745 750, e-mail: info@malux.fi, web: www.malux.fi 973 1P Arktite ® Heavy Duty Circuit Breaking Receptacle Assemblies and Housings NEMA 4 Watertight 60 A, 600 VAC/250 VDC, 50**-400 hertz Receptacle Assembly With AJ Back Boxes and Angle Adapters Style 1 Description Hub Spring Door Size Cat. # Threaded Cap Only Cat. # Mating Plug Receptacle Mating Connector with ARE Back Boxes Receptacle Housing Only Spring Door Cat. # Spring Door Cat. # Threaded Cap Only Cat. # Cable Dia. Cat. # Cat. # 2-wire, ⎫ 2-pole ⎬⎭ 1 11⁄4 AREA6213 AREA6214 ARE6213 ARE6214 AR621 AR627 0.50 to 1.45 APJ6275 APR6255 3-wire, ⎫ 3-pole ⎬⎭ 1 11⁄4 AREA6313 AREA6314 ARE6313 ARE6314 AR631 AR637 0.50 to 1.45 APJ6375 APR6355 4-wire, ⎫ 4-pole ⎬⎭ 11⁄4 11⁄2 AREA6414 AREA6415 ARE6414 ARE6415 AR641 0.50 to 1.45 APJ6475 APR6455 5-wire, ⎫ 5-pole ⎬⎭ 11⁄4 11⁄2 AR657 0.50 to 1.45 APJ6575 AREA6574 AREA6575 Style 2 2-wire, ⎫ 3-pole ⎬⎭ 1 11⁄4 AREA6323 AREA6324 ARE6323 ARE6324 AR632 AR638 0.50 to 1.45 APJ6385 APR6365 3-wire, ⎫ 4-pole ⎬⎭ 11⁄4 11⁄2 AREA6424 AREA6425 ARE6424 ARE6425 AR642 AR648 0.50 to 1.45 APJ6485 APR6465 4-wire, ⎫ 5-pole ⎬⎭ 11⁄4 11⁄2 AR658 0.75 to 1.45 APJ6585 APR6585 APR6567 Dimensions AREA6584 AREA6585 AR Receptacle - Spring Door APJ Plug ARE Assembly APR Connector AR Receptacle - Open and with cap ** For use on systems less than 60 hertz the receptacles, plugs and connectors are for disconnect use only. 974 US: 1-866-764-5454 CAN: 1-800-265-0502 Config 2P or 3P 4P 5P a 81⁄2 81⁄2 9 Plug b c 53⁄4 35⁄8 513⁄16 33⁄4 63⁄16 47⁄16 Copyright© 2006 Cooper Crouse-Hinds Malux Finland Oy, P.O.Box 69, FI-06151 PORVOO, FINLAND phone: +358 19 5745 700, fax: +358 19 5745 750, e-mail: info@malux.fi, web: www.malux.fi Connector a b c 61⁄2 35⁄8 215⁄16 81⁄4 35⁄8 215⁄16 81⁄4 35⁄8 31⁄4 Arktite® Heavy Duty Circuit Breaking Receptacle Assemblies and Housings 1P NEMA 4 Watertight 60 A, 600 VAC/250 VDC, 50**-400 hertz Plug Closure Caps: Application: CPK caps for Arktite plugs are used: ɀ where portable equipment is on a standby basis and plugs are not in use ɀ to effectively protect insulation and contacts from excessive moisture, dirt, dust and corrosion ɀ with 30, 60, 100 and 200 ampere plugs with fastening ring and standard 200 ampere plugs for the clamp door housing Standard Materials: Config. Cat No. # 2P & 3P 4P CPK32 CPK34 ɀ Copper-free aluminum Standard Finishes: ɀ Natural Replacement Parts: Config. 2W 2P 2W 3P 3W 3P 3W 4P 4W 4P 4W 5P 5W 5P Receptacle Interior ATP295 ATP298 ATP296 ATP299 ATP297 ATP385 ATP384 Plug Interior ATP290 ATP293 ATP291 ATP294 ATP292 ATP387 ATP386 Spring Door Screw Cap QE51 QE32 QE52 QE34 N/A N/A AR:11393B Recep Plug AR60CONKIT AP60CONKIT Replacement Pin & Sleeve Contacts: Description Available as a kit only. 5 phase contacts & 1 ground contact included ** For use on systems less than 60 hertz the receptacles, plugs and connectors are for disconnect use only. US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds Malux Finland Oy, P.O.Box 69, FI-06151 PORVOO, FINLAND phone: +358 19 5745 700, fax: +358 19 5745 750, e-mail: info@malux.fi, web: www.malux.fi 975 1P Arktite ® Heavy Duty Circuit Breaking Receptacle Assemblies and Housings NEMA 4 Watertight 100 A, 600 VAC/250 VDC, 50**-400 hertz Receptacle Assembly Style 1 Receptacle Housings Only Spring Door Threaded Cap Cat. # Only Cat. # Hub Description Size Spring Door Cat. # 2-wire, ⎫ 2-pole ⎬⎭ 11⁄2 AREA10214 AREA10215 AR1021 AR1027 3-wire, ⎫ 3-pole ⎬⎭ 11⁄4 11⁄2 AREA10314 AREA10315 AR1031 AR1037 4-wire, ⎫ 4-pole ⎬⎭ 11⁄2 2 AREA10415 AREA10416 AR1041 AR1047 Style 2 2-wire, ⎫ 3-pole ⎬⎭ 11⁄4 11⁄2 AREA10324 AREA10325 AR1032 AR1038 3-wire, ⎫ 4-pole ⎬⎭ 11⁄2 2 AREA10425 AREA10426 AR1042 AR1048 11⁄4 Mating Plug Receptacle Style 2 Mating Connector Cable Dia. Cat. # Cat. # 0.875 to 1.70 APJ10277 APR10257 0.875 to 1.70 APJ10377 APR10357 0.875 to 1.70 APJ10477 APR10457 Style 2 0.875 to 1.70 APJ10387 APR10367 0.875 to 1.70 APJ10487 APR10467 Dimensions ARE Assembly AR Receptacle - Spring Door APJ Plug No. Poles f 9⁄32 2 or 3 13 4 ⁄32 AR Receptacle - Open and with cap No. Poles 3 4 APR Connector No. Poles 2 or 3 4 2 or 3 4 Housing open open with cap with cap c 3 3⁄16 3 7⁄16 3 11⁄16 3 7⁄8 No. Poles 3 4 ** For use on systems less than 60 hertz the receptacles, plugs and connectors are for disconnect use only. 976 US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds Malux Finland Oy, P.O.Box 69, FI-06151 PORVOO, FINLAND phone: +358 19 5745 700, fax: +358 19 5745 750, e-mail: info@malux.fi, web: www.malux.fi b 6 9⁄16 6 5⁄8 c 3 3⁄4 4 1⁄8 b 3 3⁄8 3 1⁄2 c 3 3⁄16 3 7⁄16 Arktite® Heavy Duty Circuit Breaking Receptacle Assemblies and Housings 1P NEMA 4 Watertight Dimensions Pages 947, 961, 964-966 100 A, 600 VAC/250 VDC, 50**-400 hertz Plug Closure Caps: Application: CPK caps for Arktite plugs are used: ɀ where portable equipment is on a standby basis and plugs are not in use ɀ to effectively protect insulation and contacts from excessive moisture, dirt, dust and corrosion ɀ with 30, 60, 100 and 200 ampere plugs with fastening ring and standard 200 ampere plugs for the clamp door housing Standard Materials: Config. Cat No. # 2P & 3P 4P CPK62 CPK64 ɀ Copper-free aluminum Standard Finishes: ɀ Natural Replacement Parts: Config. 2W 2P 2W 3P 3W 3P 3W 4P 4W 4P 4W 5P 5W 5P Receptacle Interior ATP315 ATP318 ATP316 ATP319 ATP317 N/A N/A Plug Interior ATP310 ATP313 ATP311 ATP314 ATP312 N/A N/A Spring Door Screw Cap QE53 QE62 QE54 QE64 N/A N/A Recep Plug AR100CONKIT AP100CONKIT Replacement Pin & Sleeve Contacts: Description Available as a kit only. 5 phase contacts & 1 ground contact included ** For use on systems less than 60 hertz the receptacles, plugs and connectors are for disconnect use only. US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds Malux Finland Oy, P.O.Box 69, FI-06151 PORVOO, FINLAND phone: +358 19 5745 700, fax: +358 19 5745 750, e-mail: info@malux.fi, web: www.malux.fi 977 1P Arktite® Heavy Duty Circuit Breaking Receptacle Assemblies Weatherproof 200 A, 600 VAC/250 VDC, 50**-400 hertz See pages 966–969 for general Application, Features, Grounding, Standard Materials, Standard Finishes, Options, Accessories, Compliances, Electrical Rating Ranges, and Wire Sizes. Plug Closure Caps: Features: CPK caps for Arktite plugs are used: ɀ where portable equipment is on a standby basis and plugs are not in use ɀ to effectively protect insulation and contacts from excessive moisture, dirt, dust and corrosion ɀ with 30, 60, 100 and 200 ampere plugs with fastening ring and standard 200 ampere plugs for the clamp door housing Config. Standard Materials: 3P 4P ɀ Copper-free aluminum ɀ Grounding contact wire terminators will accommodate ground wire of same size as phase wire. ɀ Spring band contact design provides multiple points of electrical contact. Improves electrical reliability and significantly reduces effort required for insertion and withdrawal ɀ Crimp/solder type contacts are standard ɀ Large wire wells are available for ‘‘extra flexible’’ wire ɀ Larger wire well size connectors will interchange with connectors of other wire well size of same amperage and contact configuration. ɀ Self-closing spring doors on receptacles and cord connectors provide environmental sealing ɀ Threaded nuts provide positive plug retention ɀ Two piece plug and cord connector design provide easy installation NOTES: 1. For listing of additional back boxes, see page 991. 2. S22 suffix for reverse interiors is available from factory only. Field conversion cannot be done. 3. Replacement interiors for standard units vs. S22 units vary in length. Specify the unit type when ordering parts. Application: Cat No. # CPK102 CPK104 Standard Finishes: ɀ Natural Wire Mesh Grips: Application: Wire mesh grips are used: ɀ to provide secure cable termination ɀ to extend cable life ɀ with 20, 200 and 400 ampere plugs Dimensions AREA Assembly Features: ɀ Eliminate sharp radius of cable bend at the point where cable enters plug, thereby reducing cable failure ɀ Absorb longitudinal stresses placed on the point of termination caused by pulling the cable ɀ Gripping action increases in direct proportion to amount of tension applied to cable Standard Material & Finishes: ɀ Stainless steel wire braid – Natural Ordering Information: Plug Cable Range 1.375 to 1.875 1.875 to 2.500 AR Receptacle No. Poles 3 4 AP Plug c 4 3⁄16 4 9⁄16 Grip Range 1.375 to 1.625 1.625 to 1.875 1.875 to 2.000 2.000 to 2.250 Nominal Grip Length – Inches 8 11 10 113⁄4 APR Connector d 3 1⁄4 3 5⁄8 ** For use on system less than 60 hertz the receptacles, plugs and connectors are for disconnect use only. 978 US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds Malux Finland Oy, P.O.Box 69, FI-06151 PORVOO, FINLAND phone: +358 19 5745 700, fax: +358 19 5745 750, e-mail: info@malux.fi, web: www.malux.fi Grip Cat. # K163 K188 K200 K225 Arktite® Heavy Duty Circuit Breaking Receptacle Assemblies 1P Weatherproof 200 A, 600 VAC/250 VDC, 50**-400 hertz Receptacle Assembly Mating Plug Receptacle With AJ Back Boxes and Angle Adapters Mating Connector Receptacle Housings only Style 1 – Wire Well Takes .56⍯ Maximum Conductor Size Hub Spring Door Spring Door Description Size Cover Cat. # Cat. # 3-wire, 3-pole 11⁄2 2 21⁄2 AREA20315 AREA20316 AREA20317 4-wire, 4-pole 2 21⁄2 AREA20416 AREA20417 Cable Dia. Plug Cat. # Connector Cat. # AR2031 0.875 to 1.375 1.375 to 1.875 1.875 to 2.500 AP20355 AP20357 AP20358 APR20315 APR20317 APR20318 AR2041 0.875 to 1.375 1.375 to 1.875 1.875 to 2.500 AP20455 AP20457 AP20458 APR20415 APR20417 APR20418 1.375 to 1.875 1.875 to 2.500 AP203511 AP203512 APR203111 APR203112 1.375 to 1.875 1.875 to 2.500 2.500 to 3.000 AP204511 AP204512 AP204513 APR204111 APR204112 APR204113 Style 1 – Wire Well Takes .75⍯ Maximum Conductor Size 3-wire, 3-pole 11⁄2 2 21⁄2 AREA203125 AREA203126 AREA203127 4-wire, 4-pole 2 21⁄2 AREA204126 AREA204127 AR20312 AR20412 Style 2 – Wire Well Takes .56⍯ Maximum Conductor Size 2-wire, 3-pole 11⁄2 2 21⁄2 AREA20325 AREA20326 AREA20327 AR2032 0.875 to 1.375 1.375 to 1.875 1.875 to 2.500 AP20365 AP20367 AP20368 APR20325 APR20327 APR20328 3-wire, 4-pole 11⁄2 2 21⁄2 AREA20425 AREA20426 AREA20427 AR2042 0.875 to 1.375 1.375 to 1.875 1.875 to 2.500 AP20465 AP20467 AP20468 APR20425 APR20427 APR20428 0.875 to 1.375 1.375 to 1.875 1.875 to 2.500 AP203610 AP203611 AP203612 APR203210 APR203211 APR203212 1.375 to 1.875 1.875 to 2.500 AP204611 AP204612 APR204211 APR204212 Style 2 – Wire Well Takes .75⍯ Maximum Conductor Size 2-wire, 3-pole 11⁄2 2 21⁄2 AREA203225 AREA203226 AREA203227 AR20322 3-wire, 4-pole 11⁄2 2 21⁄2 AREA204225 AREA204226 AREA204227 AR20422 Option: ɀ Mechanical lug wire conductor terminations. Add ‘‘L’’ to catalog prefix i.e. : ARL2042 US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds Malux Finland Oy, P.O.Box 69, FI-06151 PORVOO, FINLAND phone: +358 19 5745 700, fax: +358 19 5745 750, e-mail: info@malux.fi, web: www.malux.fi 979 1P Arktite® Heavy Duty Circuit Breaking Receptacle Assemblies Weatherproof 200 A, 600 VAC/250 VDC, 50**-400 hertz 200A Replacement Parts 200A Standard and S4 Receptacle Interior .56 wire well .75 wire well Plug Interior .56 wire well Brass Retaining Shoe .75 wire well .56 wire well .75 wire well 2W 3P ATP401 ATP402 ATP433 ATP434 0490335 0490335 3W 3P ATP397 ATP398 ATP429 ATP430 0490327 0490328 3W 4P ATP403 ATP404 ATP435 ATP436 0490337 0490337 4W 4P ATP399 ATP400 ATP431 ATP432 0490331 0490332 200A ST22 and S4 S22 Receptacle Interior .56 wire well .75 wire well Plug Interior .56 wire well Brass Retaining Shoe .75 wire well .56 wire well .75 wire well 2W 3P ATP417 ATP418 ATP449 ATP450 0490335 0490335 3W 3P ATP413 ATP414 ATP445 ATP446 0490327 0490328 3W 4P ATP419 ATP420 ATP451 ATP452 0490337 0490337 4W 4P ATP415 ATP416 ATP447 ATP448 0490331 0490332 Cord Grip Assembly Cord Diameter Range .875 - 1.375 1.375 - 1.875 1.875 - 2.500 AP2 KIT1 M80 AP2 KIT2 M80 AP2 KIT3 M80 Plug Clamp Nut Rec Spring Door 2W 3P 3W 3P AP:0401965 AR:0401502-2 2W 3P 3W 3P AP:0401964 AR:0401502-1 Replacement Pin & Sleeve Contacts 200A Standard & S4 Receptacle .56 wire well .75 wire well Phase Contact Ground Contact 0490339 0490343 0490340 0490344 200A S22 & S4 S22 Receptacle .56 wire well .75 wire well Phase Contact Ground Contact 980 0490351 0490347 US: 1-866-764-5454 0490352 0490348 CAN: 1-800-265-0502 Plug .56 wire well .75 wire well 0490319 0490323 0490320 0490324 Plug .56 wire well .75 wire well 0490355T 0490359 0490356 0490360 Copyright© 2006 Cooper Crouse-Hinds Malux Finland Oy, P.O.Box 69, FI-06151 PORVOO, FINLAND phone: +358 19 5745 700, fax: +358 19 5745 750, e-mail: info@malux.fi, web: www.malux.fi Arktite® Heavy Duty Receptacle Assemblies 1P Weatherproof 400 A, 600 VAC/250 VDC, 50-400 hertz Features: ɀ Grounding contact wire terminators will accommodate ground wire of same size as phase wire ɀ Spring band contact design provides multiple points of electrical contact. Improves electrical reliability and significantly reduces effort required for insertion and withdrawal ɀ Crimp/solder type contacts are standard. ɀ Large wire wells are available for ‘‘extra flexible’’ wire ɀ Larger wire well connectors will interchange with connectors of other wire well size, of same amperage and contact configuration. ɀ Self-closing spring doors on receptacles and cord connectors provide environmental sealing ɀ Threaded nuts provide positive plug retention ɀ Two piece plug and cord connector design provide easy installation ɀ For disconnect use only – not for current interrupting NOTES: 1. For listing of additional back boxes, see page 991. Illustration shows 3 blank plates and 1 hub plate. 2. S22 suffix for reverse interiors is available from factory only. Field conversion cannot be done. 3. Replacement interiors for standard units vs. S22 units vary in length. Specify the unit type when ordering parts. Dimensions Wire mesh grips are used: ɀ to provide secure cable termination ɀ to extend cable life ɀ with 20, 200 and 400 ampere plugs Features: ɀ Eliminate sharp radius of cable bend at the point where cable enters plug, thereby reducing cable failure ɀ Absorb longitudinal stresses placed on the point of termination caused by pulling the cable ɀ Gripping action increases in direct proportion to amount of tension applied to cable Standard Material & Finishes: ɀ Stainless steel wire braid – Natural Ordering Information: Plug Cable Range 1.375 to 1.875 AREX Assemblies Description With blank hub plate With hub plate max. Wire Mesh Grips Application: 1.875 to 2.500 a Grip Range 1.375 to 1.625 1.625 to 1.875 1.875 to 2.000 2.000 to 2.250 Nominal Grip Length – Inches 8 11 10 113⁄4 Grip Cat. # K163 K188 K200 K225 5⁄16 45⁄8 AP Plugs AR Receptacles No. Poles 3 4 c 5 3⁄16 5 13⁄16 US: 1-866-764-5454 APR Connectors d 4 3⁄16 4 11⁄16 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds Malux Finland Oy, P.O.Box 69, FI-06151 PORVOO, FINLAND phone: +358 19 5745 700, fax: +358 19 5745 750, e-mail: info@malux.fi, web: www.malux.fi 981 1P Arktite® Heavy Duty Receptacle Assemblies Weatherproof 400 A, 600 VAC/250 VDC, 50-400 hertz Receptacle Assembly Receptacle Mating Plug Mating Connector With AJ Back Boxes‡ Receptacle Housings and Angle Adapters only Style 1 – Wire Well Takes .84⍯ Maximum Conductor Size Hub Size Spring Door Cover Cat.# Spring Door Cat. # Cable Dia. Plug Cat. # Connector Cat. # 3-wire, 3-pole 21⁄2 3 AREX40317 AREX40318 AR4031 1.375 to 1.875 1.875 to 2.500 AP40357 AP40358 APR40317 APR40318 4-wire, 4-pole 21⁄2 3 AREX40417 AREX40418 AR4041 1.375 to 1.875 1.875 to 2.500 AP40457 AP40458 APR40417 APR40418 2.500 to 3.000 3.000 to 3.800 AP403510 AP403512 APR403110 APR403112 2.500 to 3.000 3.000 to 3.800 AP404510 AP404512 APR404110 APR404112 1.375 to 1.875 1.875 to 2.500 AP40367 AP40368 APR40327 APR40328 1.375 to 1.875 1.875 to 2.500 AP40467 AP40468 APR40427 APR40428 2.500 to 3.000 3.000 to 3.500 AP403610 AP403612 APR403210 APR403212 2.500 to 3.000 3.000 to 3.500 AP404610 AP404612 APR404210 APR404212 Description Style 1 – Wire Well Takes 1.25⍯ Maximum Conductor Size 3-wire, 3-pole 3 31⁄2 4 AREX403128 AREX403129 AREX4031210 AR40312 4-wire, 4-pole 4 5 AREX4041210 AREX4041212 AR40412 Style 2 – Wire Well Takes .84⍯ Maximum Conductor Size 2-wire, 3-pole 2 21⁄2 3 AREX40326 AREX40327 AREX40328 AR4032 3-wire, 4-pole 21⁄2 3 AREX40427 AREX40428 AR4042 Style 2 – Wire Well Takes 1.25⍯ Maximum Conductor Size 2-wire, 3-pole 3 31⁄2 4 AREX403228 AREX403229 AREX4032210 AR40322 3-wire, 4-pole 4 5 AREX4042210 AREX4042212 AR40422 † Furnished with cable grip and neoprene bushing. 982 US: 1-866-764-5454 CAN: 1-800-265-0502 ‡ Hub plates and blank plates may be interchanged to permit conduit feed from bottom or sides. Copyright© 2006 Cooper Crouse-Hinds Malux Finland Oy, P.O.Box 69, FI-06151 PORVOO, FINLAND phone: +358 19 5745 700, fax: +358 19 5745 750, e-mail: info@malux.fi, web: www.malux.fi Non-Metallic Arktite® Heavy Duty Circuit Breaking Plugs and Receptacles Made of Krydon® Material, 600 VAC/250 VDC, 50-400 hertz; 1P Watertight§ Corrosion-Resistant NEMA 4X Dimensions Pg. 984 Application: Arktite circuit breaking plugs, receptacles, cord connectors and motor plugs are used: ɀ to supply power to portable electrical devices such as welders, motors, pumps, conveyors and other similar equipment ɀ where electrical loads must be quickly disconnected from power sources ɀ in areas where severe corrosion hose down, moisture, dirt and dust are problems ɀ indoors and outdoors in non-hazardous areas of chemical plants, sewage treatment facilities, cement plants, pulp and paper plants, food processing plants and other similar industries Features: ɀ Plugs, receptacles, cord connectors, and motor plugs are molded of Krydon fiberglassreinforced polyester material which is highly resistant to corrosion, heat, weathering and physical abuse 2-stage cord sealing system positively grips cord and protects against environmental contaminants Spring door provides environmental protection of receptacle ɀ Elastomeric snap-on caps provide environmental protection of receptacles and cord connectors ɀ Threaded construction allows quick assembly and disassembly for installation or maintenance Grounding contact circuit is made first and broken last Contact design provides multiple points of electrical contact for full-load circuit breaking capability ɀ Total interchangeability with all existing Arktite products for comparable ratings and configurations Unique environmental sealing system includes o-ring gaskets on all contacts and between housing parts for NEMA 4 integrity Threaded clamping ring provides plug retention Pressure contact wire terminals are standard. Crimp/solder terminals are optional ɀ NPQ motor plugs and NPR cable connectors offer reversed interior capability Unique cord and cable gripping system provides positive strain relief Interchangeability of Plugs With Other Non-Hazardous and Hazardous Location Receptacles: ɀ Plugs listed for use with NRE/NREA assemblies are standard NPJ Arktite plugs. Other standard APJ and CPH plugs of the same rating, style and number of poles may be used with NR receptacles, as well as with AR and AREA, receptacles listed in Section 1P, with DR receptacles listed in section 2P, with DBR, NBR, NSR, WSR, CSR, WSQC, and WSRD receptacles listed in Section 3P and with FSQ, EPC, FSQC, W2SR, C2SR and EPCB receptacles listed in Section 4P. ɀ Portable equipment, suitable for locations and equipped with the proper NPJ plug, can be used with non-hazardous AR receptacles; with DBR and WSR interlocked receptacles located in non-hazardous locations; with EPC, EPCB and FSQC receptacles for Class I, Groups B, C, D hazardous locations; with DR and DBR receptacles for Class II, Groups F, G hazardous locations; and with NBR/ NSR, CSR interlocked receptacles for hose down and corrosive locations. Standard Finishes: ɀ Krydon material – natural (gray) ɀ Neoprene – natural ɀ Elastomer – natural ɀ Brass – natural ɀ Leaded red brass – electro-tin-plated ɀ Aluminum – natural ɀ Stainless steel – natural Grounding: ɀ NPJ plugs are Style 2, which includes a grounding conductor in the flexible cord or cable that is electrically connected to the extra (grounding) pole ɀ NR receptacles are Style 2, in which the ground connection is made before line and load poles engage, and is broken after line and load poles disengage. ɀ The National Electrical Code® and Canadian Electrical Code requires that under conditions favorable to corrosion, the grounding conductor for enclosures and equipment be of copper or other corrosionresistant material in alternating current systems. This necessitates running another conductor, usually of copper, back to the common grounding electrode. This may be run through the conduit containing the circuit conductors. At the receptacle, this grounding conductor should be connected to the extra (grounding) pole by the pressure connector provided for that purpose. Where such an extra ground conductor is required, Style 2 receptacles should be used. Options: ɀ Alternate polarization (4-pole plugs and receptacles only) – Style 2 – receptacle interior Typical 3-wire, rotated 221⁄2 degrees to 4-pole plug right and plug changed and receptacle to match – add suffix S4 to Cat. No. ɀ Crimp/solder terminals – add suffix T to Cat. No. ɀ Corro-free TM epoxy powder coat on back boxes and angle adapters – information on request Certifications and Compliances: ɀ UL Standard: 1682 ɀ UL 1010 hazardous locations (NPJ plug only) ɀ Wet and damp locations, watertight ɀ CSA Standard C22.2 No. 182.1 Standard Materials: ɀ Housing, interiors, spring doors, clamping rings – Krydon fiberglass-reinforced polyester material ɀ Gaskets and o-rings – neoprene ɀ Cable clamping basket – nylon ɀ Contacts – pressure – brass; crimp/solder – leaded brass ɀ Snap-on cap – molded elastomer ɀ Back boxes – copper-free aluminum US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds Malux Finland Oy, P.O.Box 69, FI-06151 PORVOO, FINLAND phone: +358 19 5745 700, fax: +358 19 5745 750, e-mail: info@malux.fi, web: www.malux.fi 983 1P Non-Metallic Arktite® Heavy Duty Circuit Breaking Motor Plugs, Plugs & Cord Connectors Watertight§ Corrosion-Resistant NEMA 4X Made of Krydon® Material, 30 A, 60 A and 100 A 600 VAC/250 VDC, 50**–400 hertz Receptacle Assembly NREA Amps Description Receptacle Mating Plugs Snap-on Cap/ Spring Door Cat. #1 Snap-on Cap/ Spring Door Cat. #1 Cord Dia. Mating Connectors Motor Plugs NRE Hub Size Plug Cat. # Cord Connector Cat. # Motor Plug Cat. # 2-wire, 3-pole 3⁄4 1 NRE3322 NRE3323 NR332 0.55–0.70 0.70–0.85 NPJ3383 NPJ3384 NPR3363 NPR3364 NPQ338 3-wire, 4-pole 3⁄4 1 NRE3422 NRE3423 NR342 0.55–0.70 0.70–0.85 NPJ3483 NPJ3484 NPR3463 NPR3464 NPQ348 2-wire, 3-pole 1 11⁄4 NRE6323 NRE6324 NR632 0.75–1.07 1.07–1.35 NPJ6384 NPJ6385 NPR6364 NPR6365 NPQ638 3-wire, 4-pole 11⁄4 11⁄2 NRE6424 NRE6425 NR642 0.75–1.07 1.07–1.35 NPJ6484 NPJ6485 NPR6464 NPR6465 NPQ648 2-wire, 3-pole 11⁄4 11⁄2 NREA10324‡ NREA10325‡ NR1032 0.93–1.21 1.21–1.50 NPJ10386 NPJ10387 NPR10366 NPR10367 NPQ1038 3-wire, 4-pole 11⁄2 2 NREA10425‡ NREA10426‡ NR1042 0.93–1.21 1.21–1.50 NPJ10486 NPJ10487 NPR10466 NPR10467 NPQ1048 30 60 100 1 Krydon Arktite Receptacles are supplied with both a spring door and snap-on cap. § Wet and damp locations when used with spring door or snap-on cap, watertight when used with QE threaded cap. ‡ AJ back boxes are square, making it possible to install with hub in several positions. ** For use on systems less than 60 hertz the receptacles, plugs and connectors are for disconnect use only. 984 US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds Malux Finland Oy, P.O.Box 69, FI-06151 PORVOO, FINLAND phone: +358 19 5745 700, fax: +358 19 5745 750, e-mail: info@malux.fi, web: www.malux.fi Non-Metallic Arktite® Heavy Duty Circuit Breaking Motor Plugs, Plugs & Cord Connectors 1P Dimensions Made of Krydon® Material, 30 A, 60 A and 100 A 600 VAC/250 VDC, 50**–400 hertz Fig. 1 – 30 A Receptacle Assemblies Fig. 2 – 60 A Receptacle Assemblies Fig. 3 – 60 and 100 A Receptacle Assemblies NRE 30 and 60 A Assemblies – Fig. 1 NREA 60 and 100 A Assemblies – and 2 Fig. 3 Hub Size 3⁄4 1 11⁄4 11⁄2 Dimension a Dimension b 30 A 13⁄16 15⁄16 30 A 17⁄8 2 60 A 15⁄16 13⁄16 15⁄16 60 A 29⁄16 25⁄8 211⁄16 60 A Hub Size 100 A Hub Size 11⁄4, 11⁄2 2 91⁄4 913⁄16 12 12 19⁄16 19⁄16 1, 11⁄4, 11⁄2 9 11 115⁄16 Dim. a b c Fig. 6 – NPQ Motor Plugs Fig. 7 – NPJ Plugs Fig. 4 – Spring Door Housings Amps Fig. 5 – Housings with Cap 30 No. Poles 3 or 4 3 or 4 Housing Spring Door Open a 31⁄4 213⁄16 b 33⁄8 33⁄8 c — 29⁄16 d 23⁄4 23⁄4 e 12-24 12-24 Spring Door Spring Door Open Open 41⁄2 41⁄2 41⁄16 41⁄16 41⁄4 41⁄4 41⁄4 41⁄4 — — 215⁄16 31⁄4 31⁄2 31⁄2 31⁄2 31⁄2 5⁄16-18 60 3 4 3 4 Spring Door Spring Door Open Open 53⁄4 53⁄4 55⁄16 55⁄16 41⁄4 41⁄4 41⁄4 41⁄4 — — 33⁄16 37⁄16 31⁄2 31⁄2 31⁄2 31⁄2 5⁄16-18 100 3 4 3 4 Fig. 8 – NPR Cord Connectors 5⁄16-18 5⁄16-18 5⁄16-18 5⁄16-18 5⁄16-18 5⁄16-18 Amps/Poles a b NPQ Motor Plugs – Fig. 6 33⁄8 30/3 or 4 23⁄4 60/3 or 4 31⁄2 41⁄4 100/3 or 4 31⁄2 41⁄4 NPJ Plugs – Fig. 7 7 30/3 or 4 81⁄2 60/3 91⁄2 613⁄16 60/4 91⁄2 613⁄16 73⁄4 100/3 111⁄4 73⁄4 100/4 111⁄4 NPR Cord Connectors – Fig. 8 29⁄16 30/3 or 4 87⁄8 60/3 93⁄4 215⁄16 60/4 93⁄4 31⁄4 100/3 111⁄2 33⁄16 100/4 111⁄2 37⁄16 c 215⁄16 45⁄16 57⁄16 33⁄16 35⁄8 4 4 41⁄4 25⁄8 215⁄16 215⁄16 35⁄16 35⁄16 ** For use on systems less than 60 hertz the receptacles, plugs and connectors are for disconnect use only. US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds Malux Finland Oy, P.O.Box 69, FI-06151 PORVOO, FINLAND phone: +358 19 5745 700, fax: +358 19 5745 750, e-mail: info@malux.fi, web: www.malux.fi 985 1P Configured Arktite® Heavy Duty Power Connectors Rainproof 30 to 100 A 600 VAC/250 VDC 60-400 hertz Heavy-Duty and Voltage Polarized Configured Arktite® Power Connectors offer the heavy-duty metal construction of our standard Arktite line, plus voltage configuration. This combination is the ultimate in pin and sleeve connector reliability and safety. The new Configured Arktite Connector series incorporates a unique voltage polarization system that insures that only receptacles and plugs rated for the same voltage can be physically connected. This assures a safe and correct electrical connection every time. Compliance with the National Electrical Code® article 210-7 requirement for non-interchangeability of receptacles and plugs on the same premises with different voltages is now easier than ever. Equipment damage due to the misapplication of the wrong voltage using these connectors when properly installed can be virtually eliminated. This new connector series is not intermateable with our standard line of Arktite power connectors, but it utilizes many of the same time-tested construction features that have been the proven standard of excellence in the electrical industry for years. Configured Arktite Power Connectors are available in 4 or 5 pole (includes ground contact) versions for 30, 60, or 100 amp requirements. Every plug and receptacle is marked numerically and color coded for the specific voltage making it simple and easy to determine the proper plug and receptacle combination. A larger ground contact and unique keying system insures that only the connectors of the same voltage will intermate. Five distinct configurations are available covering the most common voltages in industry. Configured Arktite Power Connectors are designed for rugged use in the most abusive applications. The unique gasketing system provides a sure seal even in the most adverse environments. They also feature the Cooper Crouse-Hinds patented TRI-LOCK TM cable grip that securely locks the cable in place even when subjected to extreme flexing and jerking. The larger ground contact makes first, breaks last, and is bonded to the metal housing to insure all metal parts are properly grounded. The power contacts are specially designed and located in arc quenching chambers to allow these connectors to be safely disconnected under load. Cooper Crouse-Hinds Configured Arktite Power Connectors are designed in compliance with the latest UL, CSA and NEMA standard. Applications: Configured Arktite voltage polarized circuit breaking plugs and receptacles are used: ɀ to supply power to portable electrically operated devices such as motor-generator sets, compressors, heating and cooling units, welders, conveyors, lighting systems, and similar equipment. ɀ where temporary power is needed, such as at trailers, building units, heavy machinery, and similar equipment. ɀ wherever electrical loads must be quickly disconnected from a power source. ɀ in areas where dust, dirt, moisture, and corrosion are a problem. ɀ indoors and outdoors in non-hazardous areas of chemical plants, process industry facilities, meat packing plants, manufacturing plants, and similar industrial locations. Accessories: Accessories include a variety of angle adapters, panel adapters, and back boxes for Configured Arktite receptacles. They include protective caps for Configured Arktite plugs and receptacles. 986 US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds Malux Finland Oy, P.O.Box 69, FI-06151 PORVOO, FINLAND phone: +358 19 5745 700, fax: +358 19 5745 750, e-mail: info@malux.fi, web: www.malux.fi Configured Arktite® Heavy Duty Power Connectors 1P Rainproof 30 to 100 A 600 VAC/250 VDC 60-400 hertz Voltage/Color Configurations A 16 position ‘face’ is used to illustrate the grounding contact location for receptacles. To identify the system voltage, identify the housing color and position of the receptacle grounding contact or marking on the polarizer. Standard Materials: ɀ Metallic receptacle housings, plug, and connector bodies – high impact strength copper-free aluminum ɀ Back boxes – cast aluminum ɀ Insulators: 3, 4, and 5 pole – fiberglass-reinforced polyester ɀ Contacts: Pressure screw type – brass ɀ Polarizers – PBT polyester Standard Finishes: ɀ Aluminum – natural ɀ Fiberglass-reinforced polyester insulator – gray ɀ Brass – natural Certifications and Compliances: ɀ UL Standards: 1682 and 1686 ɀ CSA Standard: C22.2 No. 182.1 Electrical Rating Ranges: ɀ Voltage – 600 VAC; 60 to 400 hertz; 250 VDC ɀ Amperes – 30, 60, and 100 ɀ Horsepower Rating – same as standard product. See page 969. Typical Installation: Catalog Numbering System: Ordering Configured Arktite is easy. AR APJ APR APQ ⍧ Arktite Receptacle ⍧ Arktite Plug ⍧ Arktite Connector ⍧ Arktite Motor Plug AR Configured US: 1-866-764-5454 C 3 4 3 ⍧ 30 Amps 6 ⍧ 60 Amps 10 ⍧ 100 Amps CAN: 1-800-265-0502 C 4 ⍧ 4 Poles 5 ⍧ 5 Poles C ⍧ 208Y/120 VAC (Blue) E ⍧ 240 VAC 1X or 3X (Blue) K ⍧ 208 VAC 3X (Dark Blue) P ⍧ 480 VAC 1X or 3X (Red) W ⍧ 600 VAC 3X (Black) Copyright© 2006 Cooper Crouse-Hinds Malux Finland Oy, P.O.Box 69, FI-06151 PORVOO, FINLAND phone: +358 19 5745 700, fax: +358 19 5745 750, e-mail: info@malux.fi, web: www.malux.fi 987 1P Configured Arktite® Heavy Duty Power Connectorsɍ Rainproof 30/60 A 600 VAC/250 VDC 60-400 hertz 30 Amp Plugs, Receptacles, Connectors, Motor Plugs Heavy-Duty Voltage Polarized Circuit Breaking NEMA 3R Rainproof UL/CSA Amps 30 30 30 30 30 Poles 4 4 4 4 5 Volt Rating 208 VAC 3X 240 VAC 3X 480 VAC 3X 600 VAC 3X 208Y/120 VAC Color Dark Blue Blue Red Black Blue Plug Cat. No. APJC34K APJC34E APJC34P APJC34W APJC35C Receptacle w/Spring Door* Cat. No. ARC34K ARC34E ARC34P ARC34W ARC35C Back Box Ordering Information – See pages 990 and 991. 60 Amp Plugs, Receptacles, Connectors, Motor Plugs Heavy-Duty Voltage Polarized Circuit Breaking NEMA 3R Rainproof UL/CSA Amps 60 60 60 Poles 4 4 5 Volt Rating 480 VAC 3X 600 VAC 3X 208Y/120 VAC Color Red Black Blue Plug Cat. No. APJC64P APJC64W APJC65C Receptacle w/Spring Door* Cat. No. ARC64P ARC64W ARC65C Back Box Ordering Information – See pages 990 and 991. ɍ Configured Interlocks are available. – See page 1027. 988 US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds Malux Finland Oy, P.O.Box 69, FI-06151 PORVOO, FINLAND phone: +358 19 5745 700, fax: +358 19 5745 750, e-mail: info@malux.fi, web: www.malux.fi Configured Arktite® Heavy Duty Power Connectorsɍ 1P Rainproof 100 A 600 VAC/250 VDC 60-400 hertz 100 Amp Plugs, Receptacles, Connectors, Motor Plugs Heavy-Duty Voltage Polarized Circuit Breaking NEMA 3R Rainproof UL/CSA Amps 100 100 100 100 100 Poles 4 4 4 4 5 Volt Rating 208 VAC 3X 240 VAC 3X 480 VAC 3X 600 VAC 3X 208Y/120 VAC Color Dark Blue Blue Red Black Blue Plug Cat. No. APJC104K APJC104E APJC104P APJC104W APJC105C Receptacle w/Spring Door* Cat. No. ARC104K ARC104E ARC104P ARC104W ARC105C Dimensions ARC RECEPTACLES 30, 60, 100A SPRING DOOR ARC RECEPTACLES 30, 60, 100A WITH CAP APJC PLUGS ARC Receptacles Amps 30 30 60 60 100 100 Housing Spring door w/cap Spring door w/cap Spring door w/cap A 27⁄8 33⁄16 41⁄4 41⁄2 51⁄4 59⁄16 B 33⁄8 33⁄8 41⁄4 41⁄4 41⁄4 41⁄4 Amps 30 60 100 APJC Plugs A 61⁄2 81⁄2 101⁄8 B 413⁄16 513⁄16 65⁄8 C 215⁄16 33⁄4 41⁄8 C 3 311⁄16 37⁄8 D 223⁄32 223⁄32 31⁄2 31⁄2 31⁄2 31⁄2 E 12-24 12-24 5/16-18 5/16-18 5/16-18 5/16-18 F 3⁄4 9⁄32 13⁄32 ɍ Configured Interlocks are available. – See page 1027. US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds Malux Finland Oy, P.O.Box 69, FI-06151 PORVOO, FINLAND phone: +358 19 5745 700, fax: +358 19 5745 750, e-mail: info@malux.fi, web: www.malux.fi 989 1P AR Back Boxes and Accessories for 20, 30, & 60 A Receptacle Housings Dimensions Pages 992 and 993 For ARRH and ARRC back boxes ARRC ARE Hub Size 1⁄2 3⁄4 1 11⁄4 11⁄2 20/30 A Cat. # ARE13 ARE23 ARE33 60 A Cat. # ARE36 ARE46 ARE56 20/30 A Cat. # ARRH13 ARRH23 ARRH33 60 A Cat. # ARRH36 ARRH46 ARRH56 990 60 A Cat. # ARRC36 ARRC46 ARRC56 AR 15° Angle Adapter Takes AR Receptacle Housings 20 and 30 amp. AR30 ARRH and ARRC back boxes 60 amp. AR60 Steel panel or cabinet 60 and 100 amp. AR610 Mounts On ARRH and ARRC back boxes Hub Size 1⁄2 3⁄4 1 11⁄4 11⁄2 20/30 A Cat. # ARD13 ARD23 ARD33 20/30 A Cat. # ARJ13 ARJ23 ARJ33 Cat. # 60 A Cat. # ARD36 ARD46 ARD56 Spring Door Assembly Used With 30 amp, 2, 3 & 4-pole 60 amp, 2 & 3-pole 60 amp, 4-pole 100 amp, 2 & 3-pole 100 amp, 4-pole Cat. # QE50 QE51 QE52 QE53 QE54 ARJG ARJ Hub Size 1⁄2 3⁄4 1 11⁄4 11⁄2 20/30 A Cat. # ARRC13 ARRC23 ARRC33 ARD ARRH Hub Size 1⁄2 3⁄4 1 11⁄4 11⁄2 Hub Size 1⁄2 3⁄4 1 11⁄4 11⁄2 For steel panel or cabinet 60 A Cat. # ARJ36 ARJ46 ARJ56 Hub Size 1⁄2 3⁄4 1 11⁄4 11⁄2 US: 1-866-764-5454 20/30 A Cat. # ARJG13 ARJG23 ARJG33 60 A Cat. # Cap and Chain ARJG36 ARJG46 ARJG56 CAN: 1-800-265-0502 Used With 30 amp, 2, 3 & 4-pole 60 amp, 2 & 3-pole 60 amp, 4-pole 100 amp, 2 & 3-pole 100 amp, 4-pole Copyright© 2006 Cooper Crouse-Hinds Malux Finland Oy, P.O.Box 69, FI-06151 PORVOO, FINLAND phone: +358 19 5745 700, fax: +358 19 5745 750, e-mail: info@malux.fi, web: www.malux.fi Cat. # QE13 QE32 QE34 QE62 QE64 AJ and AJC Back Boxes with Angle Adapters for 60, 100, 200 & 400 A Receptacle Housings AJX Assemblies and Component Parts For 200 and 400 A Receptacle Housings 1P Dimensions Pages 992 and 993 AJX Assemblies Back Box with Angle Adapter, 3 Blank Plates and 1 Hub Plate AJ Back Box with 60/100 A Angle Adapter AJ Back Box with 200/400 A Angle Adapter Hub Size 2 21⁄2 3 31⁄2 4 5 400 A Cat. # AJX69 AJX79 AJX89 AJX929 AJX9210 AJX9212 AJX Component Parts For use in making up assemblies with arrangements of hub plates (4 required) other than those listed. AJC Back Box with 60/100 A AJA Angle Adapter AJC Back Box with 200 A Angle Adapter AJ and AJC Back Boxes † 60 & 100A HUB SIZE TYPE BOX ONLY 200A BOX & ADAPTER ASSEMBLY ONE HUB AJ56* AJ37 FEED THRU AJC56* AJC37 400A BOX ONLY BOX & ADAPTER ASSEMBLY BOX ONLY BOX & ADAPTER ASSEMBLY AJ71* AJ58 AJ71* AJ68 AJ82* AJ69 AJ71 AJ78 AJ82* AJ79 1⍯ ONE HUB AJ56* AJ47 FEED THRU AJC56* AJC47 Back Box Angle Adapter 400 A Cat. # AJX99 400 A Cat. # AJ245 11⁄4⍯ ONE HUB AJ56 AJ57 FEED THRU AJC56 AJC57 11⁄2⍯ ONE HUB AJ66 AJ67 FEED THRU AJC66 AJC67 2⍯ ONE HUB Hub Plate 21⁄2⍯ FEED THRU AJC71 AJC78 ONE HUB AJ82 AJ89 3⍯ FEED THRU ANGLE ADAPTER AJA6 AJA1 AJA2 *REDUCER SUPPLIED WITH ASSEMBLY † AJ and AJC back boxes are square, making it possible to install with hub in several positions. ‡ Use AJ69, AJ79 or AJ89 for cables up to 2 – #350MCM, 3 – #300MCM or 4 – #250MCM. For larger cables, use AJX69, etc., listed under assemblies. US: 1-866-764-5454 CAN: 1-800-265-0502 Hub Size 2 21⁄2 3 31⁄2 4 5 400 A Cat. # YYP96 YYP97 YYP98 YYP99 YYP910 YYP9012 Copyright© 2006 Cooper Crouse-Hinds Malux Finland Oy, P.O.Box 69, FI-06151 PORVOO, FINLAND phone: +358 19 5745 700, fax: +358 19 5745 750, e-mail: info@malux.fi, web: www.malux.fi Blank Plate 400 A Cat. # YYP900 991 1P Back Boxes Dimensions 20, 30 A 60 A AJX Back Body ARE Cat. # 13 23 33 36 46 56 Rating 20, 30A 20, 30A 20, 30A 60 A 60 A 60 A Size 1⁄2 3⁄4 1 1 11⁄4 11⁄2 a 127⁄32 127⁄32 131⁄32 29⁄16 25⁄8 211⁄16 400 Amperes b 11⁄16 13⁄16 15⁄16 15⁄16 13⁄16 15⁄16 Hub Plate Hub Size YYP96 2 YYP97 21⁄2 YYP98 3 YYP99 31⁄2 YYP910 4 YYP9012 5 ARJG Cat. # 13 23 33 36 46 56 Rating 20, 30A 20, 30A 20, 30A 60 A 60 A 60 A Size 1⁄2 3⁄4 1 1 11⁄4 11⁄2 a 33⁄8 33⁄8 33⁄8 41⁄4 41⁄4 41⁄4 b 415⁄32 415⁄32 419⁄32 55⁄8 511⁄16 53⁄4 c 23⁄4 23⁄4 23⁄4 411⁄16 411⁄16 411⁄16 d 41⁄4 41⁄4 41⁄4 51⁄4 51⁄4 51⁄4 h Dia. 11⁄32 11⁄32 11⁄32 3⁄8 3⁄8 3⁄8 e 13⁄8 13⁄8 13⁄8 15⁄8 15⁄8 15⁄8 AJ Angle Adapter AJ and AJC With 60, 100, 200 and 400 Ampere Angle Adapters Cat. # Rating Size a b 57⁄8 8 37, 47, 57 60, 100 A 1, 11⁄4, 11⁄2 8 67 60, 100A 2 57⁄8 8 103⁄4 58, 68, 78 200 A 11⁄2, 2, 21⁄2 1 9 115⁄8 69, 79, 89 400 A 2, 2 ⁄2, 3 992 US: 1-866-764-5454 c 77⁄16 8 97⁄8 1113⁄16 CAN: 1-800-265-0502 d 47⁄8 47⁄8 63⁄4 73⁄4 ‘‘A’’ 33⁄4 37⁄8 37⁄8 37⁄8 37⁄8 45⁄8 e 7 7 91⁄2 103⁄8 f 15° 15° 45° 45° Copyright© 2006 Cooper Crouse-Hinds Malux Finland Oy, P.O.Box 69, FI-06151 PORVOO, FINLAND phone: +358 19 5745 700, fax: +358 19 5745 750, e-mail: info@malux.fi, web: www.malux.fi ‘‘B’’ 111⁄16 25⁄16 25⁄16 29⁄16 213⁄16 37⁄16 1P Back Boxes Dimensions ARRC and ARRH Cat. # 13 23 33 36 46 56 Rating 20/30 A 20/30 A 20/30 A 60 A 60 A 60 A Size 1⁄2 3⁄4 1 1 11⁄4 11⁄2 a 33⁄8 33⁄8 33⁄8 41⁄4 41⁄4 41⁄4 b 55⁄16 55⁄16 55⁄16 61⁄2 61⁄2 61⁄2 c 25⁄8 25⁄8 25⁄8 31⁄2 31⁄2 31⁄2 d 49⁄16 49⁄16 49⁄16 53⁄4 53⁄4 53⁄4 e 21⁄4 21⁄4 21⁄4 31⁄8 31⁄8 31⁄8 f Dia. 11⁄32 11⁄32 11⁄32 7⁄16 7⁄16 7⁄16 g 11⁄16 13⁄16 15⁄16 13⁄8 13⁄8 13⁄8 AR30 and AR60 Angle Adapters Cat. # AR30 AR60 Rating 20/30 A 60 A a 33⁄8 41⁄4 b 41⁄8 415⁄16 ARD Cat. # 13 23 33 36 46 56 Rating 20/30 A 20/30 A 20/30 A 60A 60 A 60 A Size 1⁄2 3⁄4 1 1 11⁄4 11⁄2 a 33⁄8 33⁄8 33⁄8 41⁄4 41⁄4 41⁄4 b 55⁄16 55⁄16 55⁄16 71⁄16 71⁄16 71⁄16 c 323⁄32 323⁄32 323⁄32 53⁄4 53⁄4 53⁄4 d 41⁄4 41⁄4 41⁄4 51⁄8 51⁄8 51⁄8 e 127⁄32 127⁄32 127⁄32 23⁄4 23⁄4 23⁄4 f Dia. 11⁄32 11⁄32 11⁄32 3⁄8 3⁄8 3⁄8 g 11⁄16 13⁄16 15⁄16 15⁄16 15⁄16 15⁄16 AR610 Angle Adapter ARJ Cat. # 13 23 33 36 46 56 Rating 20/30 A 20/30 A 20/30 A 60 A 60 A 60 A Size 1⁄2 3⁄4 1 1 11⁄4 11⁄2 a 33⁄8 33⁄8 33⁄8 41⁄4 41⁄4 41⁄4 b 35⁄8 35⁄8 35⁄8 411⁄16 411⁄16 411⁄16 US: 1-866-764-5454 c 23⁄4 23⁄4 23⁄4 411⁄16 411⁄16 411⁄16 d 45⁄8 45⁄8 45⁄8 5 5 5 CAN: 1-800-265-0502 e 17⁄32 17⁄32 17⁄32 123⁄32 123⁄32 123⁄32 f 55⁄16 55⁄16 55⁄16 63⁄8 63⁄8 63⁄8 h Dia. 11⁄32 11⁄32 11⁄32 3⁄8 3⁄8 3⁄8 j 15⁄16 15⁄16 15⁄16 15⁄16 15⁄16 15⁄16 Copyright© 2006 Cooper Crouse-Hinds Malux Finland Oy, P.O.Box 69, FI-06151 PORVOO, FINLAND phone: +358 19 5745 700, fax: +358 19 5745 750, e-mail: info@malux.fi, web: www.malux.fi 993 1P AR Arktite® Circuit Breaking Round Flange Receptacle Housings for Panel Mounting Application: AR round flange receptacle housings are designed specifically for semi-flush mounting in sheet metal panels or cabinets. Features: ɀ Back boxes are not needed for these receptacle assemblies. ɀ Where wiring behind a panel is exposed and subject to either mechanical injury or contact by personnel, suitable shields or guards should be provided. APJ Plugs with cable grip, Neoprene bushing and fastening ring Standard Materials: ɀ Receptacle housings – copper-free aluminum ɀ Plug exteriors – copper-free aluminum ɀ Insulation: 30, 60, 100, 200 ampere – fiberglass-reinforced polyester ɀ Pressure and solder contacts – brass ɀ Crimp/solder contacts – leaded red brass AR Receptacle housings with round flange and threaded cap AP Plugs with cable grip, Neoprene bushing and fastening ring Standard Finishes: ɀ Copper-free aluminum – natural ɀ Brass – natural ɀ Fiberglass-reinforced polyester – natural (red) ɀ Leaded red brass – electro-tin-plate Options: Available with these assemblies are: ɀ Reversed interiors (add suffix S22 to Cat. No.) ɀ Special polarity (add suffix S4 to Cat. No.) See page 968 for details. Certifications and Compliances: ɀ UL Standard: 1682 NOTE: For general information on application, features and grounding, see pages 966 to 969. 994 US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds Malux Finland Oy, P.O.Box 69, FI-06151 PORVOO, FINLAND phone: +358 19 5745 700, fax: +358 19 5745 750, e-mail: info@malux.fi, web: www.malux.fi AR Arktite® Circuit Breaking Round Flange Receptacle Housings for Panel Mounting With Threaded Cap 1P Weatherproof 30/60/100/200 A, 600 VAC/250 VDC, AP and APJ Plugs Amps 30 Style‡ Description 3-wire, * 1 3-pole 4-wire, * 4-pole 2 3-wire, * 4-pole } } } 3-wire, 3-pole 4-wire, 4-pole 3-wire, 4-pole }* }* }* 3-wire, 3-pole 4-wire, 4-pole 3-wire, 4-pole }* }* }* 1 3-wire, 3-pole } 2 2-wire, 3-pole } 1 60 2 1 100 2 200 Recept. Cat. # Cable Dia. Plug Cat. # AR6337 0.60 to 1.20 APJ3375 AR6347 0.60 to 1.20 APJ3475 AR6348 0.60 to 1.20 APJ3485 AR6637 0.75 to 1.45 APJ6375 AR6647 0.75 to 1.45 APJ6475 AR6648 0.75 to 1.45 APJ6485 AR61037 1.00 to 1.70 APJ10377 AR61047 1.00 to 1.70 APJ10477 AR61048 1.00 to 1.70 APJ10487 ⎧ .875 to 1.375 AR62031ɍ ⎨ ⎩ 1.875 to 2.500 ⎧ .875 to 1.375 AR62032ɍ ⎨ ⎩ 1.875 to 2.500 AP20355 AP20358 AP20365 AP20368 ‡ Style 1 – Grounded through shell. Style 2 – Grounded through extra pole and shell. ɍ 200 ampere size is provided with clamp cover. * Pressure connectors are standard. Crimp/solder type terminators are optionally available for 2, 3 and 4-pole 30 ampere, 3 and 4-pole 60 and 100 ampere. For details, see table on page 969. To specify, add the suffix ‘‘T’’ to the catalog number. For example: APJ3375-T (Plug) AR6337-T (Receptacle) Dimensions AR Round Flange Receptacles Description 30 amp. 2, 3, 4-pole 60 amp. 2, 3-pole 60 amp. 4-pole 100 amp. 2, 3-pole 100 amp. 4-pole 200 amp. 3-pole a 2 b 12-24 c 43⁄4 d 27⁄16 e 15⁄8 f 21⁄4 2 12-24 43⁄4 213⁄16 17⁄8 33⁄8 2 12-24 43⁄4 31⁄8 17⁄8 33⁄8 2 12-24 43⁄4 31⁄16 17⁄8 49⁄16 2 12-24 43⁄4 35⁄16 17⁄8 49⁄16 33⁄8 3⁄8-16 73⁄4 43⁄16 27⁄8 51⁄8 AP 200A Plugs APJ 30, 60 and 100A Plugs Amps 30 60 60 100 100 200 No. Poles 2, 3 or 4 2 or 3 4 2 or 3 4 3 a 61⁄2 81⁄2 81⁄2 101⁄8 101⁄8 143⁄4 b 413⁄16 53⁄4 513⁄16 69⁄16 65⁄8 1011⁄16 c 215⁄16 35⁄8 33⁄4 33⁄4 41⁄8 63⁄4 † These dimensions are approximate and vary with cable size. US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds Malux Finland Oy, P.O.Box 69, FI-06151 PORVOO, FINLAND phone: +358 19 5745 700, fax: +358 19 5745 750, e-mail: info@malux.fi, web: www.malux.fi 995 1P APQ Arktite® Circuit Breaking Motor Plugs NEMA 4 Watertight APJ Plugs, APR Cable Connector Receptacles 30/60/100 A, 250 VDC/600 VAC, 50**-400 hertz Application: APQ motor plugs are used: ɀ on portable electric equipment Features: ɀ Eliminates problem of storing and protecting a long length of portable cord and plug on portable device ɀ Connection to fixed receptacle used as power source is made with cord sets which may be hung on wall, out of the way ɀ Cord sets are made up using an APR receptacle at one end and an APJ plug at the other ɀ Cord sets may be used singly or connected together to provide longer lengths when needed ɀ With spare cord sets on hand, portable equipment may be kept in service while normal cord replacement is being made ɀ Where design of portable equipment permits, APQ motor plugs can be attached directly to a sheet metal panel or cabinet ɀ May be mounted on AR and AJ back boxes for conduit connection ɀ See typical installation diagram on page 997 APR Cable connector receptacles with cable grip, Neoprene bushing, and protected contacts. APQ Motor plugs with square flange, gaskets, fastening ring, and exposed contacts. APJ Plugs with cable grip, Neoprene bushing, exposed contacts, and fastening ring. Standard Materials: ɀ Motor plugs: mounting plate – Feraloy®, Iron Alloy; protective sleeve – copper-free aluminum ɀ Plug and receptacle exteriors – copper-free aluminum ɀ Back boxes – copper-free aluminum ɀ Insulation – fiberglass-reinforced polyester ɀ Pressure and solder contacts – brass ɀ Crimp/solder contacts – leaded red brass Amps Style‡ 1 30 Standard Finishes: ɀFeraloy – electrogalvanized and aluminum acrylic paint ɀ Copper-free aluminum – natural ɀ Brass – natural ɀ Fiberglass-reinforced polyester – natural (red) ɀ Leaded red brass – electro-tin-plate 2 1 Options: Available with these assemblies: ɀ Special polarity (add suffix S4 to Cat. No.) See page 968 for details. 60 2 Certifications and Compliances: ɀ UL Standards: 514, 1682 ɀ CSA Standard C22.2 No. 182.1 NOTE: For general information on application, features and grounding, refer to pages 966 to 969. 1 100 ‡ Style 1 – Grounded through shell. Style 2 – Grounded through extra pole and shell. * Pressure connectors are standard. Crimp/solder terminators are optionally available for 2, 3 and 4 pole 30 ampere. 3 and 4-pole 60 and 100 ampere. For details, see page 969. To specify, add the suffix ‘‘T’’ to the catalog number. For example: APR3355-T (Connector) APJ3375-T (Plug) 2 Description 2-wire, ⎫⎬ * 2-pole ⎭ 3-wire, ⎫ * ⎬ 3-pole ⎭ 4-wire, ⎫ * ⎬ 4-pole ⎭ 2-wire, ⎫ * ⎬ 3-pole ⎭ 3-wire, ⎫⎬ * 4-pole ⎭ 2-wire, ⎫ * 2-pole ⎬⎭ 3-wire, ⎫ * 3-pole ⎬⎭ 4-wire, ⎫ * 4-pole ⎬⎭ 2-wire, ⎫ * 3-pole ⎬⎭ 3-wire, ⎫ * 4-pole ⎬⎭ 2-wire, ⎫ ⎬ 2-pole ⎭ 3-wire, ⎫ ⎬ 3-pole ⎭ 4-wire, ⎫ ⎬ 4-pole ⎭ 2-wire, ⎫ ⎬ 3-pole ⎭ * * * * 3-wire, ⎫ * ⎬ 4-pole ⎭ Plug Cat. # APJ3275 APJ3375 APJ3475 APJ3385 APJ3485 APJ6275 APJ6375 APJ6475 APJ6385 APJ6485 APJ10277 APJ10377 APJ10477 APJ10387 APJ10487 Cable Dia. 0.60 to 0.88 0.87 to 1.02 0.60 to 0.88 0.87 to 1.02 0.60 to 0.88 0.87 to 1.02 0.60 to 0.88 0.87 to 1.02 Cable Connector Receptacle Cat. # APR3253 APR3255 APR3353 APR3355 APR3453 APR3455 APR3363 APR3365 0.60 to 0.88 0.87 to 1.02 APR3463 APR3465 0.75 to 0.88 0.87 to 1.37 0.75 to 0.88 0.87 to 1.37 0.75 to 0.88 0.87 to 1.37 0.75 to 0.88 0.87 to 1.37 APR6253 APR6255 APR6353 APT6355 APR6453 APR6455 APR6363 APR6365 0.75 to 0.88 0.87 to 1.37 APR6463 APR6465 1.00 to 1.38 1.37 to 1.50 1.00 to 1.38 1.37 to 1.50 1.00 to 1.38 1.37 to 1.50 1.00 to 1.38 1.37 to 1.50 APR10255 APR10257 APR10355 APR10357 APR10455 APR10457 APR10365 APR10367 1.00 to 1.38 1.37 to 1.50 APR10465 APR10467 ** For use on systems less than 60 hertz the receptacles, plugs and connectors are for disconnect use only. 996 US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds Malux Finland Oy, P.O.Box 69, FI-06151 PORVOO, FINLAND phone: +358 19 5745 700, fax: +358 19 5745 750, e-mail: info@malux.fi, web: www.malux.fi Motor Plug Cat. # APQ327 APQ337 APQ347 APQ338 APQ348 APQ627 APQ637 APQ647 APQ638 APQ648 APQ1027 APQ1037 APQ1047 APQ1038 APQ1048 Weatherproof Typical Back Boxes 1P For APQ Arktite® Circuit Breaking Motor Plugs Typical back boxes used with APQ motor plugs ARE AJ For APQ 30 Amp. For APQ 60 and 100 Amp. Hub Size 1⁄2 3⁄4 1 Hub Size 1 11⁄4 11⁄2 2 Cat. # ARE13 ARE23 ARE33 For APQ 60 Amp. Hub Size 1 11⁄4 11⁄2 Cat. # AJ37 AJ47 AJ57 AJ67 Cat. # ARE36 ARE46 ARE56 Dimensions Typical installation APQ Motor Plugs Amps. a 30 23⁄4 60 31⁄2 100 31⁄2 (2 & 3-pole) b 33⁄8 41⁄4 41⁄4 c 35⁄8 47⁄8 61⁄8 s 12-24 5⁄16-18 5⁄16-18 31⁄2 41⁄4 67⁄16 5⁄16-18 100 (4-pole) US: 1-866-764-5454 For additional back box listings, see pages 990 and 991. For back box dimensions, see pages 992 and 993. CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds Malux Finland Oy, P.O.Box 69, FI-06151 PORVOO, FINLAND phone: +358 19 5745 700, fax: +358 19 5745 750, e-mail: info@malux.fi, web: www.malux.fi 997