High­voltage neon­sign cable
Construction data
NEN: RMvL 3/6kV
Application:
· High voltage connections in neon­sign installations, for
cable runs in metal cabinets
· Also suitable as ignition cable
General properties:
· Very good tracking resistance
· Resistant to corona discharges
· Small bending radius
· Very flexible
Remarks:
· NEN­EN 50143 applies for the installation
· There must be a sufficient distance between the
connections and grounded metal parts
· Because of the tracking resistance of the EPR insulation,
about 3 cm of the sheath should be removed extra at the
termination
· Cable joints should be avoided
· The use of a corona­resistant termination kit is
recommended
· The cable may not be fixed with metal clamps
Nominal cross section conductor
Number of cores
Core insulation
Screen
Drain wire
Material outer sheath
Colour outer sheath
Outer diameter approx.
Conductor material
Conductor category
Nom diam over insulation
Weight
Properties
Permitted cable outer temperature, fixed
Permitted cable outer temperature, in
movement
Bending radius
Max. tensile force
Nominal voltage U0
Nominal voltage U
Core colour:
1 core: yellow
Standards/References:
NEN­EN 50143
Additional information:
Minimum installation temperature: 0 °C
Operating temperature: min. ­40 °C, max. +80 °C
Sheath colour: black
Packaging: coils, drums
The information in this document is subject to change without notice. Although the information in this document has been
compiled, and is maintained, with great care, Draka Kabel B.V. cannot guarantee that the available information is
complete and/or correct. Draka Kabel B.V. cannot accept liability for any consequences, such as damage or loss of profits
in any way as a result of using, relying on or actions undertaken as a result of information in this document.\r\n\r\n
Tel. helpdesk 088­808 4420 e­mail info@draka.nl ­40 / 80 gr.C
0 / 80 gr.C
70 mm
75 N
Electrical
Construction:
Conductor: flexible tinned copper (class 5)
Insulation: ethylene propylene rubber (EPR)
Outer sheath: polyvinyl chloride (PVC)
Electrical properties:
Voltage rating: 6 kV
Test voltage: 12 kV
1/3
1.5 mm²
1
Rubber (EPR)
No
No
PVC
Black
6.8 mm
Copper, bare
Class 5 =
flexible
4.7 mm
65 kg/km
10/1/2016
6000 V
6000 V
High voltage Neon sign cable 3/6 kV
High­voltage neon­sign cable
Product Range
Product Nominal cross
nr. section (mm²)
101451
1,5
Nominal diameter over
insulation (mm)
4,7
Nominal overall
diameter (mm)
6,8
Minimum bending Maximum tensile
radius strength (mm)
(N)
70
75
The information in this document is subject to change without notice. Although the information in this document has been
compiled, and is maintained, with great care, Draka Kabel B.V. cannot guarantee that the available information is
complete and/or correct. Draka Kabel B.V. cannot accept liability for any consequences, such as damage or loss of profits
in any way as a result of using, relying on or actions undertaken as a result of information in this document.\r\n\r\n
2/3
Tel. helpdesk 088­808 4420 e­mail info@draka.nl 10/1/2016
Approx.
weight (kg/km)
65
High voltage Neon sign cable 3/6 kV
High­voltage neon­sign cable
Electrical features
Product nr. Nominal cross section (mm²)
101451
1,5
The information in this document is subject to change without notice. Although the information in this document has been
compiled, and is maintained, with great care, Draka Kabel B.V. cannot guarantee that the available information is
complete and/or correct. Draka Kabel B.V. cannot accept liability for any consequences, such as damage or loss of profits
in any way as a result of using, relying on or actions undertaken as a result of information in this document.\r\n\r\n
3/3
Tel. helpdesk 088­808 4420 e­mail info@draka.nl 10/1/2016
Download