High voltage Neon sign cable 3/6 kV High­voltage neon­sign cable Construction data NEN: RMvL 3/6kV Application: · High voltage connections in neon­sign installations, for cable runs in metal cabinets · Also suitable as ignition cable General properties: · Very good tracking resistance · Resistant to corona discharges · Small bending radius · Very flexible Remarks: · NEN­EN 50143 applies for the installation · There must be a sufficient distance between the connections and grounded metal parts · Because of the tracking resistance of the EPR insulation, about 3 cm of the sheath should be removed extra at the termination · Cable joints should be avoided · The use of a corona­resistant termination kit is recommended · The cable may not be fixed with metal clamps Nominal cross section conductor Number of cores Core insulation Screen Drain wire Material outer sheath Colour outer sheath Outer diameter approx. Conductor material Conductor category Nom diam over insulation Weight Properties Permitted cable outer temperature, fixed Permitted cable outer temperature, in movement Bending radius Max. tensile force Nominal voltage U0 Nominal voltage U Core colour: 1 core: yellow Standards/References: NEN­EN 50143 Additional information: Minimum installation temperature: 0 °C Operating temperature: min. ­40 °C, max. +80 °C Sheath colour: black Packaging: coils, drums The information in this document is subject to change without notice. Although the information in this document has been compiled, and is maintained, with great care, Draka Kabel B.V. cannot guarantee that the available information is complete and/or correct. Draka Kabel B.V. cannot accept liability for any consequences, such as damage or loss of profits in any way as a result of using, relying on or actions undertaken as a result of information in this document.\r\n\r\n Tel. helpdesk 088­808 4420 e­mail info@draka.nl ­40 / 80 gr.C 0 / 80 gr.C 70 mm 75 N Electrical Construction: Conductor: flexible tinned copper (class 5) Insulation: ethylene propylene rubber (EPR) Outer sheath: polyvinyl chloride (PVC) Electrical properties: Voltage rating: 6 kV Test voltage: 12 kV 1/3 1.5 mm² 1 Rubber (EPR) No No PVC Black 6.8 mm Copper, bare Class 5 = flexible 4.7 mm 65 kg/km 10/1/2016 6000 V 6000 V High voltage Neon sign cable 3/6 kV High­voltage neon­sign cable Product Range Product Nominal cross nr. section (mm²) 101451 1,5 Nominal diameter over insulation (mm) 4,7 Nominal overall diameter (mm) 6,8 Minimum bending Maximum tensile radius strength (mm) (N) 70 75 The information in this document is subject to change without notice. Although the information in this document has been compiled, and is maintained, with great care, Draka Kabel B.V. cannot guarantee that the available information is complete and/or correct. Draka Kabel B.V. cannot accept liability for any consequences, such as damage or loss of profits in any way as a result of using, relying on or actions undertaken as a result of information in this document.\r\n\r\n 2/3 Tel. helpdesk 088­808 4420 e­mail info@draka.nl 10/1/2016 Approx. weight (kg/km) 65 High voltage Neon sign cable 3/6 kV High­voltage neon­sign cable Electrical features Product nr. Nominal cross section (mm²) 101451 1,5 The information in this document is subject to change without notice. Although the information in this document has been compiled, and is maintained, with great care, Draka Kabel B.V. cannot guarantee that the available information is complete and/or correct. Draka Kabel B.V. cannot accept liability for any consequences, such as damage or loss of profits in any way as a result of using, relying on or actions undertaken as a result of information in this document.\r\n\r\n 3/3 Tel. helpdesk 088­808 4420 e­mail info@draka.nl 10/1/2016