Ultraviolet Disinfection Systems

advertisement
Systems tested and certified by NSF International against NSF/
ANSI Standard 55 for disinfection performance, Class A.
Ultraviolet Disinfection Systems
Who is VIQUA - a Trojan
Technologies Company
VIQUA is a leading water
treatment technology company
focused on providing our
customers – residential and
light commercial – confidence in
their water. Offering a complete
solution package including UV
disinfection, water filtration,
softeners and ozone products.
What is UV?
Ultraviolet (UV) light is at the
invisible, violet end of the light
spectrum. The water treatment
industry uses a high-powered
form of UV light called UV-C or
“germicidal UV” to disinfect water.
Ensuring the safety of your water.
How does UV light work?
UV-C rays penetrate
microorganisms and destroy their
ability to reproduce, effectively
rendering them harmless.
It’s a simple but effective process,
destroying a minimum of 99.99%
of harmful microorganisms,
including E. coli, Cryptosporidium,
and Giardia.
Not only is it safe and highly
effective, UV does not change
the taste, color, or odor of water.
It simply removes the risk of
illness caused by microbial
contamination, making water safe.
UV disinfection for drinking water is an
acceptable alternative disinfectant under
the drinking water regulations worldwide,
as long as the equipment has proof of
performance (third party validation).
NSF is a certified testing facility that
conducts UV validations under the NSF 55
Class A protocol.
Why not use chlorine?
Chlorine changes the taste and
odor of water. Chlorination may
also produce harmful by-products
that are linked to the incidence
of cancer.
Sterilight SPV systems have undergone
validation with NSF and hold certification to
deliver an accepted dose of 40 mJ/cm2.
Who uses UV
disinfection systems?
For more than 30 years,
institutions, consumers and
businesses have relied on VIQUA’s
environmentally friendly UV
technology to disinfect their
water supplies. Top candidates
for UV disinfection systems
include:
Rural homes and cottages
Nursing homes
• Hospitals
• Schools
• Hotels
• Restaurants
• Resorts and holiday camps
•
Community water systems
•
•
Systems tested and certified by NSF International against NSF/
ANSI Standard 55 for disinfection performance, Class A.
Safety-Loc™ Lamp Connector
The interlock switch easily allows
users simple, safe lamp removal
without the use of special tools.
Combo Ports
For ease of installation
[all point-of-entry
systems].
Flow-Pace™ UV Sensor
This UV sensor promises system
stability and long-life reliability with
low power consumption, reduced
operational costs and less heat
transfer into the water.
Axial Flow
Sterilight® Platinum™ reactors
include a patented axial flow
system installed at the inlet. The
axial flow directs water entering
the chamber to the most intense
area of UV light – ensuring water
confidence each and every time.
Electropolished and
Passivated Reactor Chamber
Manufactured from 316L stainless
steel.
Platinum ICE Controller
> graphic interface (Smart Switch™)
> visual UV intensity output in %
> universal power (100-250V)
> constant current output
> visual elapsed time meter (counts
down remaining days between lamp
changes and provides for total running
time of controller)
> full system diagnostic check on start-up
Sizing Your System
The UV dose delivered by a given reactor is
dependent on many factors, including water
quality and flow rate. NSF/ANSI Standard 55
requires that the UV system deliver a minimum
UV fluence of 40 mJ/cm2 at the alarm setpoint. The accompanying graph shows how the
delivered fluence will be affected at varying UV
transmittance levels.
> dry contacts (for solenoid etc.)
> universal IEC power input connector
TIME OF DAY
00
2:00
PM
Press to Scroll
Through Information
Screens
Electronic ICE Controller / Contrôleur Électronique ICE
Input Voltage 100–250V~ 50/60Hz / Tension d'alimentation 100–250 V~ 50/60 Hz
Max. Input Current 1.3A, Operates one, Sterilume™ — 15W–100W, High Output UV Lamp
Maxi. d’alimentation 1,3 A, Pour une lampe UV Sterilume™ — 15 W–100 W, flux élevé intensité
For Indoor Use Only / Pour utilisation à l'intérieur seulement
Case Must Be Grounded / Le boîtier doit être relié à la terre
For Use In Permanently Connected Equipment Only / Pour utilisation seulement dans un équipement connecté en permanence
Disconnect Power Before Servicing / Débrancher l’alimentation électrique avant d’exécuter les travaux.
Appuyer pour faire défiler
les écrans d’information
Danger - High voltage electrical shock hazard DO NOT OPEN /
Tension électrique élevée risque de choc électrique NE PAS OUVRIR
Caution - See owner’s manual before installation /
Attention - Voir le manuel de l’utilisateur avant d’installer
Patent Pending
Brevet demandé
510275
Typical Point-of-entry Illustration
Water Quality Guidelines
Iron: < 0.3 ppm (0.3 mg/L)
Manganese: < 0.05 ppm (0.05 mg/L)
Hardness: < 7 gpg (120 mg/L)
Tannins: <0.1 ppm (0.1 mg/L)
Turbidity: < 1 NTU
UV Transmittance: > 75%
Lamps
Sterilume HO lamps utilize low pressure high output technology in order to deliver superior performance.
All SPV lamps include the following:
> Proprietary lamp coating
> Consistent UV output
> Superior cold water start conditions
> One year warranty
VIQUA - a Trojan Technologies company offers a wide range of certifications, both electrical and
microbiological, throughout the Sterilight product line. VIQUA cannot warranty any system or system
components if non-genuine parts are used, specifically lamps. Getting genuine ensures maintenance of
your system warranty, electrical certification and NSF 55 validation. Ensure the performance, safety and
warranty of your Sterilight systems…get genuine.
General
Chamber Material
316L SS
Electropolished &
Passivated
Yes
UV Intensity Monitor
Yes
Flow Pacing – Sensor
Yes
Elapsed Time Meter
Countdown
Yes
Total Hours
Yes
Rated flow
at dose of
40 mJ/cm2
1
SPV-200
spv-410
spv-600
spv-740
spv-950
9.9 lpm
(2.6 gpm)
(0.5 m3//hr)
22.6 lpm
(5.9 gpm)
(1.3 m3//hr)
32.7 lpm
(8.6 gpm)
(1.9 m3//hr)
42.9 lpm
(11.2 gpm)
(2.5 m3//hr)
56.6 lpm
(14.9 gpm)
(3.4 m3//hr)
Electrical
Voltage
100-250V/50-60 Hz
Power
Consumption
35 W
52 W
73 W
88 W
110 W
Lamp Watts
30 W
45 W
65 W
80 W
100 W
Reactor
45 cm x 9 cm
(18“ x 3.5“)
67 cm x 9 cm
(26“ x 3.5“)
86 cm x 9 cm
(34“ x 3.5“)
100 cm x 9 cm
(39“ x 3.5“)
121 cm x 9 cm
(48“ x 3.5“)
Controller
28 cm x 11 cm
(11“ x 4.5“)
28 cm x 11 cm
(11“ x 4.5“)
28 cm x 11 cm
(11“ x 4.5“)
28 cm x 11 cm
(11“ x 4.5“)
28 cm x 11 cm
(11“ x 4.5“)
Shipping
Weight
5.4 kg
(12 lbs)
6.8 kg
(15 lbs)
8.2 kg
(18 lbs)
8.6 kg
(19 lbs)
9.5 kg
(21 lbs)
1/2“ MNPT
Combo
3/4“ FNPT/
1“ MNPT
Combo
3/4“ FNPT/
1“ MNPT
Combo
3/4“ FNPT/
1“ MNPT
Combo
3/4“ FNPT/
1“ MNPT
Dimensions
Controls
Flow Restrictor
Yes
Dry Contacts
Yes
Lamp Replacement
Reminder
Yes
Diagnostic Check
Yes
Inlet/Outlet
Port Size
Operating Parameters
Maximum Operating
Pressure
8.62 bar (125 psi)
Minimum Operating
Pressure
1 bar (14.5 psi)
Pressure Drop at Rated
Flow
Ambient Water
Temperature
0.3 bar (4 psi)
at 50% rated flow*
2-40˚C (36-104˚F)
Maximum Ambient
Temperature
Installation
50˚C (122˚F)
1
Flow rates stated as determined by NSF/ANSI Standard 55 testing.
Warranty
The Sterilight® Platinum™ Series systems come with a seven year
warranty against manufacturer’s defects on the stainless steel reactor
chamber; a one year warranty on lamps, sleeves, and UV intensity
monitors; and a five year pro-rated warranty on all other components.
Horizontal or Vertical
NSF/ANSI Certification
Standard 55
Class A
Other Certifications
* pressure drop due to flow restrictor
Systems tested and certified by NSF
International against NSF/ANSI Standard
55 for disinfection performance, Class A.
425 Clair Road West Guelph, ON Canada N1L 1R1
t. 519 763 1032 t.f. 800 265 7246 f. 519 763 5069
www.viqua.com
LIT-0303139 Printed in Canada. © VIQUA - a Trojan Technologies Company 2010