Systems tested and certified by NSF International against NSF/ ANSI Standard 55 for disinfection performance, Class A. Ultraviolet Disinfection Systems Who is VIQUA - a Trojan Technologies Company VIQUA is a leading water treatment technology company focused on providing our customers – residential and light commercial – confidence in their water. Offering a complete solution package including UV disinfection, water filtration, softeners and ozone products. What is UV? Ultraviolet (UV) light is at the invisible, violet end of the light spectrum. The water treatment industry uses a high-powered form of UV light called UV-C or “germicidal UV” to disinfect water. Ensuring the safety of your water. How does UV light work? UV-C rays penetrate microorganisms and destroy their ability to reproduce, effectively rendering them harmless. It’s a simple but effective process, destroying a minimum of 99.99% of harmful microorganisms, including E. coli, Cryptosporidium, and Giardia. Not only is it safe and highly effective, UV does not change the taste, color, or odor of water. It simply removes the risk of illness caused by microbial contamination, making water safe. UV disinfection for drinking water is an acceptable alternative disinfectant under the drinking water regulations worldwide, as long as the equipment has proof of performance (third party validation). NSF is a certified testing facility that conducts UV validations under the NSF 55 Class A protocol. Why not use chlorine? Chlorine changes the taste and odor of water. Chlorination may also produce harmful by-products that are linked to the incidence of cancer. Sterilight SPV systems have undergone validation with NSF and hold certification to deliver an accepted dose of 40 mJ/cm2. Who uses UV disinfection systems? For more than 30 years, institutions, consumers and businesses have relied on VIQUA’s environmentally friendly UV technology to disinfect their water supplies. Top candidates for UV disinfection systems include: Rural homes and cottages Nursing homes • Hospitals • Schools • Hotels • Restaurants • Resorts and holiday camps • Community water systems • • Systems tested and certified by NSF International against NSF/ ANSI Standard 55 for disinfection performance, Class A. Safety-Loc™ Lamp Connector The interlock switch easily allows users simple, safe lamp removal without the use of special tools. Combo Ports For ease of installation [all point-of-entry systems]. Flow-Pace™ UV Sensor This UV sensor promises system stability and long-life reliability with low power consumption, reduced operational costs and less heat transfer into the water. Axial Flow Sterilight® Platinum™ reactors include a patented axial flow system installed at the inlet. The axial flow directs water entering the chamber to the most intense area of UV light – ensuring water confidence each and every time. Electropolished and Passivated Reactor Chamber Manufactured from 316L stainless steel. Platinum ICE Controller > graphic interface (Smart Switch™) > visual UV intensity output in % > universal power (100-250V) > constant current output > visual elapsed time meter (counts down remaining days between lamp changes and provides for total running time of controller) > full system diagnostic check on start-up Sizing Your System The UV dose delivered by a given reactor is dependent on many factors, including water quality and flow rate. NSF/ANSI Standard 55 requires that the UV system deliver a minimum UV fluence of 40 mJ/cm2 at the alarm setpoint. The accompanying graph shows how the delivered fluence will be affected at varying UV transmittance levels. > dry contacts (for solenoid etc.) > universal IEC power input connector TIME OF DAY 00 2:00 PM Press to Scroll Through Information Screens Electronic ICE Controller / Contrôleur Électronique ICE Input Voltage 100–250V~ 50/60Hz / Tension d'alimentation 100–250 V~ 50/60 Hz Max. Input Current 1.3A, Operates one, Sterilume™ — 15W–100W, High Output UV Lamp Maxi. d’alimentation 1,3 A, Pour une lampe UV Sterilume™ — 15 W–100 W, flux élevé intensité For Indoor Use Only / Pour utilisation à l'intérieur seulement Case Must Be Grounded / Le boîtier doit être relié à la terre For Use In Permanently Connected Equipment Only / Pour utilisation seulement dans un équipement connecté en permanence Disconnect Power Before Servicing / Débrancher l’alimentation électrique avant d’exécuter les travaux. Appuyer pour faire défiler les écrans d’information Danger - High voltage electrical shock hazard DO NOT OPEN / Tension électrique élevée risque de choc électrique NE PAS OUVRIR Caution - See owner’s manual before installation / Attention - Voir le manuel de l’utilisateur avant d’installer Patent Pending Brevet demandé 510275 Typical Point-of-entry Illustration Water Quality Guidelines Iron: < 0.3 ppm (0.3 mg/L) Manganese: < 0.05 ppm (0.05 mg/L) Hardness: < 7 gpg (120 mg/L) Tannins: <0.1 ppm (0.1 mg/L) Turbidity: < 1 NTU UV Transmittance: > 75% Lamps Sterilume HO lamps utilize low pressure high output technology in order to deliver superior performance. All SPV lamps include the following: > Proprietary lamp coating > Consistent UV output > Superior cold water start conditions > One year warranty VIQUA - a Trojan Technologies company offers a wide range of certifications, both electrical and microbiological, throughout the Sterilight product line. VIQUA cannot warranty any system or system components if non-genuine parts are used, specifically lamps. Getting genuine ensures maintenance of your system warranty, electrical certification and NSF 55 validation. Ensure the performance, safety and warranty of your Sterilight systems…get genuine. General Chamber Material 316L SS Electropolished & Passivated Yes UV Intensity Monitor Yes Flow Pacing – Sensor Yes Elapsed Time Meter Countdown Yes Total Hours Yes Rated flow at dose of 40 mJ/cm2 1 SPV-200 spv-410 spv-600 spv-740 spv-950 9.9 lpm (2.6 gpm) (0.5 m3//hr) 22.6 lpm (5.9 gpm) (1.3 m3//hr) 32.7 lpm (8.6 gpm) (1.9 m3//hr) 42.9 lpm (11.2 gpm) (2.5 m3//hr) 56.6 lpm (14.9 gpm) (3.4 m3//hr) Electrical Voltage 100-250V/50-60 Hz Power Consumption 35 W 52 W 73 W 88 W 110 W Lamp Watts 30 W 45 W 65 W 80 W 100 W Reactor 45 cm x 9 cm (18“ x 3.5“) 67 cm x 9 cm (26“ x 3.5“) 86 cm x 9 cm (34“ x 3.5“) 100 cm x 9 cm (39“ x 3.5“) 121 cm x 9 cm (48“ x 3.5“) Controller 28 cm x 11 cm (11“ x 4.5“) 28 cm x 11 cm (11“ x 4.5“) 28 cm x 11 cm (11“ x 4.5“) 28 cm x 11 cm (11“ x 4.5“) 28 cm x 11 cm (11“ x 4.5“) Shipping Weight 5.4 kg (12 lbs) 6.8 kg (15 lbs) 8.2 kg (18 lbs) 8.6 kg (19 lbs) 9.5 kg (21 lbs) 1/2“ MNPT Combo 3/4“ FNPT/ 1“ MNPT Combo 3/4“ FNPT/ 1“ MNPT Combo 3/4“ FNPT/ 1“ MNPT Combo 3/4“ FNPT/ 1“ MNPT Dimensions Controls Flow Restrictor Yes Dry Contacts Yes Lamp Replacement Reminder Yes Diagnostic Check Yes Inlet/Outlet Port Size Operating Parameters Maximum Operating Pressure 8.62 bar (125 psi) Minimum Operating Pressure 1 bar (14.5 psi) Pressure Drop at Rated Flow Ambient Water Temperature 0.3 bar (4 psi) at 50% rated flow* 2-40˚C (36-104˚F) Maximum Ambient Temperature Installation 50˚C (122˚F) 1 Flow rates stated as determined by NSF/ANSI Standard 55 testing. Warranty The Sterilight® Platinum™ Series systems come with a seven year warranty against manufacturer’s defects on the stainless steel reactor chamber; a one year warranty on lamps, sleeves, and UV intensity monitors; and a five year pro-rated warranty on all other components. Horizontal or Vertical NSF/ANSI Certification Standard 55 Class A Other Certifications * pressure drop due to flow restrictor Systems tested and certified by NSF International against NSF/ANSI Standard 55 for disinfection performance, Class A. 425 Clair Road West Guelph, ON Canada N1L 1R1 t. 519 763 1032 t.f. 800 265 7246 f. 519 763 5069 www.viqua.com LIT-0303139 Printed in Canada. © VIQUA - a Trojan Technologies Company 2010 No part of this publication may be reproduced, stored in a retrieval system, or transmitted in any form or by any means without the written permission of VIQUA.