our New Heater Guide - 4

advertisement
Heater Guide
2015/2016
Temporary Heating Solutions
(4929)
Contents
Indirect Fired Heaters
Diesel Fired Heaters
320,000 to 878,000 BTU
Up to 500,000 BTU
Page 5-8
Page 7
Up to 1,000,000 BTU
Direct Fired Heaters
Pages 5-6
12,000 to 1 million BTU
Page 9-10
LPG/NG Fired Heaters
Radiant Heaters
Up to 50,000 BTU
Pages 9-10
UP to 125,000 BTU
Page 11-12
Up to 500,000 BTU
Hydronic Heaters
Up to 1,000,000 BTU
Pages 9-10
Ground heaters, thaw ground or cure concrete
Page 13-18
Pages 9,12
Electric Heaters
Environmentally Friendly
Heaters
1500 to 4800 watt / 16,000 BTU
Pages 5, 6 & 12
Page 19
Temporary Lighting
Lighting towers, carts, LED & string lights
Page 20
Fuel Services
Propane tanks, diesel fuel cells & delivery
Page 21
Generators
2 kW to 240 kW
Page 22-23
Accessories
Extension cords, insulated tarps & ducts
Page 24
E
F
Technical Information
Page 25
780.464.4929
www.4-way.com
1
Contents
Worry Free Winter Heating
Equipment, Logistics, Delivery & Fuel (Propane & Diesel)
in One Convenient Package
Short, Medium and Long Term Price Packages Available
Heater Delivery, Hanging and Connecting
Permitting
Regular Fuel Rotation
7 Day Follow Up Inspection & Report
Weekly Rental Reports
24/7 Call-out Service
www.4-way.com
2
HEATER GUIDE
Complete 360° Winter Construction Services
OVER 30 YEARS OF HEATING EXPERIENCE
LARGEST SELECTION OF HEATERS AVAILABLE
780.464.4929
www.4-way.com
3
Higher Efficiency Makes A Difference
Outside
Temperature
Type of Heater
Fuel Consumption and Output
350,000 BTU Heater
0°C
56°C
OUTPUT
Two 350,000 BTU Heaters
-20°C
36°C
OUTPUT
Three 350,000 BTU Heaters
-40°C
26°C
OUTPUT
One 900,000 BTU HEATER
108°C
OUTPUT
One 900,000 BTU HEATER
108°C
OUTPUT
One 900,000 BTU HEATER
108°C
OUTPUT
=
=
=
10°C
10°C
10°C
Ask us how you can save fuel and rental costs
this winter with our high efficiency heaters.
www.4-way.com
4
Indirect Fired Heaters
Arctic Bear™ XHD
770,00 BTU
MANUFACTURED BY: WACKER NEUSON
High Efficiency Indirect Fired Air Heaters
Fuel Source - Diesel
Features
Specs
Ÿ
Ÿ
Ÿ
Ÿ
Fuel Capacity: 968 Liters
Weight without fuel 5,700 lbs
Weight with fuel 7,543 lbs
Run time 45-75 hrs
Ÿ High Efficiency Heater with
Unique Recircul-Air design
(Adjust recirculation for fuel savings and even temperatures)
Ÿ Digital Control Thermostat Control
Onboard
Thermostat
Ÿ Strobe light shows that unit is operating
To Control Your Costs
Ÿ 240 degree temperature rise
Ÿ 100% Spill contained
Power Requirement
On board generator
Ducting Options
Ÿ Perforated - For improved heat distribution
Ÿ High Temp - Required for 240° temperature rise.
Ÿ Yellow - Can be attached to high temp ducts to extend length
780.464.4929
www.4-way.com
5
Indirect Fired Heaters
Hi750 Diesel, LPG & NG 750,000 BTU
MANUFACTURED BY: WACKER NEUSON
Mobile Indirect Fired Air Heater
The HI750 can handle heating and drying applications with
750,000 BTUs/hr at over 83% efficiency. The most versatile,
robust indirect fired air heaters produce clean, moisture free air
for various heat applications.
Hi900 Diesel, LPG & NG 870,000 BTU
MANUFACTURED BY: WACKER NEUSON
Mobile Indirect Fired Air Heater 878,000 BTU
The HI900 can handle heating and drying lications with 878,000
BTUs/hr at over 83% efficiency. The most versatile, robust
indirect fired air heaters produce clean, moisture free air for
various heat applications.
Specs - HI750
Ÿ
Ÿ
Ÿ
Ÿ
Fuel Capacity: 450 Liters
Weight without fuel 2,567 lbs
Weight with fuel 3,400 lbs
Able to fit through 36" door opening
Specs - Hi900
Ÿ
Ÿ
Ÿ
Ÿ
Fuel Capacity: 450 Liters
Weight without fuel 2,567 lbs
Weight with fuel 3,400 lbs
Able to fit through 36" door opening
www.4-way.com
Remote thermostat
available!
Control Your Costs
Power requirements - HI750 & Hi900
1-120VOLTS 15amps
1-240VOLTS 30amps
6
Indirect Fired Heaters
Frost Fighters 350K & 500K BTU
MANUFACTURED BY: INDUSTRIAL COMMERCIAL EQUIPMENT MANUFACTURING LTD.
Clean & safe high capacity heating
The frost fighter provides clean air, free from moisture and
contaminated fumes.
Fuel Source: Diesel, NG & LPG
Thermostat fuel savings
The following chart is based on outdoor heaters running at maximum
output to maintain the building conditions at the 0 F. point. With the
heaters cycling on a thermostat as the ambient air temperature
increases by the indicated amount the fuel savings would be as
indicated.
Specs
MAX CAPACITY
HEATED AIR
DISCHARGE TEMP
FUEL
TANK CAPACITY
NOZZLE
SIZE/PRESSURE
BURNER MOTOR
(115V, 60 CYCLE)
FAN MOTOR
NET WEIGHT
(APPROX.)
SHIPPING WEIGHT
(APPROX.)
FINISH
AIR OUTLETS OPTIONAL ONE 6"
IDF 350-11 OIL
IDF 500 OIL
IDF 350 LP/NG
IDF 500 LP/NG
OHV 350 - OIL
OHV 500 - OIL
OHV 350 - LP/NG
OHV 500 - LP/NG
320,000 BTU
500,000 BTU
350,000 BTU
420,000 BTU
320,000 BTU
420,000 BTU
350,000 BTU
450,000 BTU
2,800 CFM
3,100 CFM
2,800 CFM
3,100 CFM
2,500 CFM
3,100 CFM
2,500 CFM
3,100 CFM
200°F W/DUCT
180°F W/DUCT
220°F W/DUCT
220°F W/DUCT
CREATING 0.4"
CREATING 0.5"
CREATING 0.4"
CREATING 0.5"
STATIC
STATIC
STATIC
STATIC
200°F
180°
200°F
210°F
PRESSURE
PRESSURE
PRESSURE
PRESSURE
FUEL OIL
FUEL OIL
35 IMP/ 42 US
35 IMP/ 42 US
GALLONS
GALLONS
FUEL OIL
FUEL OIL
35 IMP/ 42 US
35 IMP/ 42 US
GALLONS
GALLONS
2.0 U.S. GPH
2.5 U.S. GPH
@125PSI
@145PSI
PROPANE/
PROPANE/
NATURAL GAS
NATURAL GAS
-
-
LP/NG-1.8"W.C.
LP/NG-2.8"W.C.
-
1/4 HP
1/4 HP
1/4 HP
LP/NG 2.8"W.C.
1/4 HP
-
-
-
1/2 HP
1 HP
1/2 HP
1 HP
520 LBS
520 LBS
520 LBS
520 LBS
N/A
N/A
N/A
N/A
570 LBS
570 LBS
550 LBS
550 LBS
467 LBS
467 LBS
455 LBS
455 LBS
POWDER COAT
POWDER COAT
POWDER COAT
POWDER COAT
POWDER COAT
POWDER COAT
STANDARD- TWO STANDARD- TWO STANDARD- TWO STANDARD- TWO
12" DIAMETER
12" DIAMETER
DIMENSIONS CRATED
70"x35"x50"
70"x35"x50"
70"x36"x50"
70"x36"x50"
(LxWxH)
83"x37"x52"
83"x37"x52"
83"x37"x52"
83"x37"x52"
CSA
CSA
ETL
ETL
780.464.4929
-
-
12" DIAMETER
APPROVAL
PROPANE/
NATURAL GAS
2.0 GPH @125PSI 2.5 GPH @145PSI LP/NG - 1.8"W.C.
1/3HP, 3450 RPM 1/3HP, 3450 RPM 1/3HP, 3450 RPM 1/3HP, 3450 RPM
12" DIAMETER
DIAMETER
PROPANE/
NATURAL GAS
www.4-way.com
POWDER COAT
POWDER COAT
N/A
N/A
N/A
N/A
83"x37.5"x52.5"
83"x37.5"x52.5"
83"x37.5"x52.5"
83"x37.5"x52.5"
CSA
CSA
ETL
ETL
7
Indirect Fired Heaters
IHS 700 Ice Fighter
MANUFACTURED BY: INDUSTRIAL COMMERCIAL EQUIPMENT MANUFACTURING LTD.
Large capacity, high static 700 indirect
The ICE FIGHTER IHS is engineered for specialized applications
and for customers requiring a high pressure, high air flow heating
system.
Fuel Source: Diesel
Specs
Features
Weight without fuel 1,600 lbs
Ÿ Up to 4" (W.C.) static pressure
Ÿ Different voltage, 208v 3 phase or 240v single
Remote thermostat
available!
Control Your Costs
Power requirement
Ÿ
Ÿ
Ÿ
Ÿ
Ÿ
Ÿ
Ÿ
phase options
Recirculation options for increased efficiency
Industrial style blower
Up to 1.25 million BTU
Standard 16" outlets and inlets
Remote thermostat available
Powder coated and fully insulated
Variable frequency drive for low amp draw
240 VOLTS 50 amps
208 VOLTS 30 amps (3Ø)
What is indirect fired heat?
1
(CO )EXHAUST OUT
Indirect fired heating is where
combustion occurs within a chamber or
burner, harmful byproducts are vented
outside and clean dry air heat is
transferred by a heat exchanger.
The heat is usually ducted into
a structure by either canvas or
sheet metal ducting. Indirect fired
heating has become the number
www.4-way.com
2
(H O) OUT
HOT AIR OUT
DRY AIR
COLD
AIR IN
FUEL IN
one choice for heating construction projects
for various reasons. The main reasons
include workplace safety, energy savings and
a moisture free heat.
8
Direct Fired Heaters
Sureflame S100
MANUFACTURED BY: SUREFLAME
Portable dual fuel direct fired heater
Fuel source: LPG/NG
Ÿ
Ÿ
Ÿ
Ÿ
Ÿ
Ÿ
Ÿ
Convenient carrying handle
Extremely quiet
Portable – Light weight - 52 lbs
BTU Rating: 100,000 btu/hr
Easy ball valve switch over from LPG to NG
4.1L/hr Propane
Sureflame S400R
MANUFACTURED BY: SUREFLAME
Portable dual fuel direct fired heater
Fuel source: LPG/NG
Ÿ
Ÿ
Ÿ
Ÿ
Ÿ
Ÿ
Powder coated shell for high impact resistance
3 safety shut down controls
Light weight. – 85lbs
BTU Rating: 400,000 btu/hr
Easy ball valve switch over from LPG to NG
16.5L/hr Propane
Sureflame SL11E
MANUFACTURED BY: SUREFLAME
Portable dual fuel direct fired heater
Fuel source: LPG/NG
Ÿ
Ÿ
Ÿ
Ÿ
Ÿ
Ÿ
Electrical system designed for lower voltage
Easy one person relocation
BTU Rating: 1,000,000 btu/hr
Easy ball valve switch over from LPG to NG
41.3L/hr Propane
285 lbs
What is direct fired heat?
Direct fired or open flame heaters are
typically used in situations where a high
degree of heat is required in large open
areas. Such as loosely enclosed structure.
COLD
AIR IN
HOT AIR OUT
(CO1)EXHAUST OUT
(H2O) OUT*
FUEL IN
Any heater burning fossil fuel produces
combustion byproducts such as carbon
dioxide and monoxide which can
be hazardous to workers in the area.
Ventilation is key when using these heaters.
*Up to 40% of Propane is water
*Up to 5% of Natural Gas is water
780.464.4929
www.4-way.com
9
Direct Fired Heaters
Premier Series
up to 350,000 BTU
MANUFACTURED BY: L.B.WHITE
Fuel source: LPG/NG
Premier® Ductable unit heaters
L.B. White’s Premier series of ductable direct-fired heaters are
perfect for small, hard to reach areas, as well as large
construction applications that require directed heat. And the
Premier 350 DF with its dual fuel capability offers even greater
flexibility and efficiency.
Power requirement
Delivering clean, worry-free heating and air circulation where you
need it, Premier heaters feature:
1-120VOLTS 15amps
PREMIER 80
BTU/Hr Rating
Maximum
Ignition System
Heated Air Output (CFM)
Fuel Consumption (max.)
Propane (lbs/hr)
Natural Gas (cu.ft/hr)
Inlet Gas Pressure
Propane min/max (in W.C.)
Natural Gas min/max (W.C.)
Electrical Supply (Volts/Hz/Phase)
Amps (Starting/Cont. Oper.)
Wheels
Fan only mode
Dimensions (in)
Length
Width
Height
Net Weight (lbs)
Shipping Weight (lbs)
Gas Pressure Regulator (w/ POL)
Thermostat (weatherproof, 20' cord)
Gas Hose
Ducting** (12" or 18" dia. X 12' length)
80,000
170,000
350,000
Direct Spark
450
Direct Spark
1200
Direct Spark
2400
3.7
80
7.9
170
16.2
12 / 13.5
8 / 13.5
115 / 60 / 1
5 / 1.5
11 / 13.5
11 / 13.5
115 / 60 /1
7.3 / 5
*Not Listed
www.4-way.com
115 / 60 /1
30 / 14
Tri-Shield Coating* Tri-Shield Coating* Tri-Shield Coating*
-Semi-pneumatic Semi-pneumatic
S
S
S
30
14
20
81
88
S
S
15'
Gray - 26346
Light Duty - 26348
CSA U.S./Canada Certification:
PREMIER 170 DF PREMIER 350
Yes
31
18
29
154
162
S
S
15'
Gray - 26346
48
22
41
295
350
S
S
15'
Gray - 26346
Light Duty - 26348 Light Duty - 26348
Yes
Yes
10
Radiant Heaters
HXS1001
125,000 BTU
MANUFACTURED BY: HEATSTAR
Fuel source: LPG/NG
Portable radiant heater
125000 BTU
LPG or NG
Heats up to 3000 square feet
No electricity required.
Heats during power outages
CSA certified
Ÿ
Ÿ
Ÿ
Ÿ
Ÿ
Ÿ
Ÿ
Ÿ
Must be at least 4 sq ft area in total left open for ventilation.
Must be 4ft from the top & 8ft around unit from any combustible
What is radiant heat?
Radiant heaters are available as either
natural gas or propane fired and need no
electricity to run. Output is around 125,000
BTU per hr. – more than your average
house furnace. The heater flame is
contained inside a vented metal tube, which
is heated until red hot. This style of heater
does not heat the air directly, but generates
an infrared wave which heats surfaces as it
contacts them. This produces an even heat
distribution with minimal air circulation.
The combustion byproducts are vented
directly to atmosphere, and can pose a
hazard unless adequate ventilation is
provided. Propane also contains a significant
amount of water and this moisture will be
introduced into the structure when this fuel is
used. Natural gas contains very little water
and has the added advantage of not needing
monitoring for fueling. Hoses can be fitted
with male ATCO fittings to quick connect to
your construction gas meters.
Maintenance & trouble shooting
TROUBLESHOOTING TIPS FOR RADIANT HEATERS
1. Won’t light? If you are firing it up for the first time, please be patient while the gas or propane
gets all the way to the heater. It can take up to 5 minutes for natural gas to fill the hose due to
the low pressure and size of hose. Propane is much quicker but still takes a while to fill a 50 ft.
hose assembly for the first time.
2. Heater shut off? Sometimes bumping the heater will shut it off. There is a tip over safety
switch so you have to relight it manually. If it appears stubborn check to see that the tip over
switch is not bent from being knocked about.
3. No fuel to heater? Check to see if hose is blocked, or has snow in it. Especially if it is a
propane hose the opening is small and fills quickly.
4. Also check your regulator – it needs to be set properly in order for fuel to get to the heater.
5. Lastly, check your fuel source.
780.464.4929
www.4-way.com
11
Infrared Fired Heaters
VAL6 KBE5L
MANUFACTURED BY: VAL6
Direct fired heater
Fuel source: Diesel
The KBE5L model has a large 15 gallon tank for longer
operation and better efficiency.
Power requirement
110 VOLTS 0.8amps
VAL6
Ÿ
Ÿ
Ÿ
Ÿ
Ÿ
Ÿ
Ÿ
Perfect heater for areas up to 500 sq ft
Portable
Heats quickly
Odorless
98% efficiency
Units need only 100w of power to run
Fuel: diesel
Serious Toasters
MANUFACTURED BY: SERIOUS THERMAL PRODUCTS LTD.
Infrared ground thawing equipment
Fuel source: LPG
Ÿ
Ÿ
Ÿ
Ÿ
Ÿ
Ÿ
Ÿ
www.4-way.com
Easy Setup – 2 men can move it.
Fits in a pick-up box
Safe - No open flame means you can place them anywhere.
Low Maintenance – minimal moving parts.
Thaw up to 1.6 inches per hour
Only burns 1lb propane/hr
120V 0.8A power required.
12
Hydronic Heaters
E1100
MANUFACTURED BY: WACKER NEUSON
Reliable mobile hydronic heating
Fuel source: Diesel
The hydronic ground heater product line is designed to quickly,
easily and economically thaw frozen ground, cure concrete, and
prevent frost during cold weather conditions.
Features
Ÿ
Ÿ
Specs
Ÿ
Ÿ
Ÿ
Fuel Capacity 272 liters
Weight without fuel 2,283 lbs
Weight with fuel 2,716 lbs
Ÿ
Ÿ
Ÿ
Ÿ
Ÿ
Ÿ
Mobile, quick and easy heating
Thaw/cure up to 1,800 square feet, extend size by adding
accessories
Up to 115 hours run time
Flexible, easy setup
Positive displacement pump for consistent heating
Digital temperature controller
Strobe light shows that unit is operating from a
distance
87% efficiency - highest in the industry
Power requirement
Contact your sales rep
For a detailed quote and estimate!
1-120VOLTS 15amps
Every job site is different
Ground heaters can be very effective
when used properly for thawing ground,
frost prevention, or concrete curing of
slabs on grade, walls, bridge decks and
grade beams.
Ground heaters are among the most
efficient units available for thawing ground
and curing concrete when used correctly.
Savings are realized from fuel savings,
reduced thaw times, and labor savings
compared to traditional hoarding
techniques.
In some cases simply maintaining a tight
schedule makes these the right heaters to
use for thawing and curing applications.
Setup of Ground Heaters is simple and the
flexibility of the hose allows for many
different configurations. Past applications
even include the use of pex tubing in a slab
or grade beam application to provide heat
prior to, during and after your pour. Please
call for an assessment of your jobsite and
scheduling needs.
Did you know?
All our hydronic heaters can be hooked into in-floor heating systems during the
entire construction & afterwards for maintenance.*
*SOME LIMITATIONS APPLY
780.464.4929
www.4-way.com
13
Hydronic Heaters
E2200
MANUFACTURED BY: WACKER NEUSON
Durable & user-friendly hydronic heating
Fuel source: Diesel
The E 2200 will thaw up to 3,300 sq. ft. of frozen ground. This unit
can also heat up to 3,300 sq. ft. of ground, indoors or out, to
prepare for concrete placement, to prevent frost penetration or to
ensure proper concrete curing.
Specs
Ÿ
Ÿ
Ÿ
Fuel Capacity: 700 liters
Weight without fuel 5,240 lbs
Weight with fuel 6,297 lbs
Power requirement
1-120VOLTS 15amps
Features
Ÿ Thaw/cure up to 3,300 square feet, extend size
Ÿ
Ÿ
Ÿ
Ÿ
by adding accessories
Reliable starting, up to 130 hours run time
Digital temperature controller
Strobe light shows that unit is operating
from a distance
87% efficiency - highest in the industry
for hydronic heaters
Cost savings
How many BTUs does it take to
convert 1 lb. of ice into water?
143 BTUs! Clay and silt can hold
between 16 to 52 pounds of ice
per cubic foot. It takes 3100 to
7500 BTUs to melt the ice
contained in 1 cubic foot of soil!
With hot air heating, most of your
heat is going into the atmosphere
instead of into the ground. You
also have to contend with noisy
heaters, fumes, expensive
enclosures, fluctuating fuel costs,
and constant supervision.
Wouldn’t it be nice not to have to hoard an enclosure
and baby-sit a propane heater at all hours during the
night? Ground Heaters require no hoarding, little
supervision, at about a 1/3 of the cost of traditional
hot air heating. Call us to get more information or visit
our website at www.4-way.com.
TRADITIONAL METHOD
85%
HEAT
SOURCE
FROZEN SOIL
15% OF THE HEAT
CONDUCTED INTO THE GROUND!
www.4-way.com
GROUND
HEATERS
INSULATION BLANKETS
POLY VAPOR BARRIER
FROZEN SOIL
94% OF THE HEAT
CONDUCTED INTO THE GROUND!
14
Hydronic Heaters
E3000
MANUFACTURED BY: WACKER NEUSON
Reliable mobile hydronic heating
Fuel source: Diesel
The Hydronic Ground Heater product line is easy to operate and dependable.
The E 3000 will provide maximum flow and ensure consistent heat delivery for
thawing and curing applications. One pump per hose loop means more
BTU's/hr delivered to the project than competitive hydronic units. This unit
thaws or cures up to 4500 sq. ft. – with accessories, the E 3000 will cure up to
18,000 sq. ft. or provide 535,000 cu. ft. of dry heat.
Features
Specs
Ÿ
Ÿ
Ÿ
Ÿ
Fuel Capacity: 870 liters
Weight without fuel 6,105 lbs
Weight with fuel 7,715 lbs
Also available with a NG burner.
Ÿ
Ÿ
Ÿ
Ÿ
Ÿ
Power requirement
140 hours of run time.
3,000 ft. of hose
Positive displacement pump
Digital temperature controller
Unit features 83% heater efficiency, the
highest in the industry.
2-120VOLTS 15amps
CH5000
MANUFACTURED BY: WACKER NEUSON
Hydronic heater for multiple applications
Fuel source: Diesel, LPG & NG
The largest, most versatile Ground Heater, the CH 5000 thaws, cures,
prevents frost, heats and dries all without the use of additional pump packs.
The unique pump system provides maximum flow rate regardless of the
application. This unit thaws or cures up to 9000 sq. ft. - with accessories, the
CH 5000 will cure up to 30,000 sq. ft., heat up to 1,700,000 cu. ft, or provide
576,000 cu. ft. of dry heat. The CH 5000 offers 3 fuel options: diesel, natural
gas or propane, for maximum jobsite convenience.
Features
Specs
Ÿ
Ÿ
Ÿ
Fuel Capacity: 950 litres
Weight without fuel 9,725 lbs
Weight with fuel 11,500 lbs
Ÿ
Ÿ
Ÿ
Ÿ
Ÿ
64 hours of run time (Diesel fuel).
5,000 ft. of hose
Powerful pump system
Digital temperature controller
Unit features 83% heater efficiency,
the highest in the industry.
Power requirement
1-120VOLTS 15amps
1-240VOLTS 50amps
780.464.4929
www.4-way.com
15
Hydronic Heaters
Pureheat
MANUFACTURED BY: WACKER NEUSON
Fuel sources: Diesel, LPG/NG
Space & thawing heater
Removes excess moisture from the workspace, and saves up to
50% of the fuel over traditional methods.
Features
Specs
Ÿ
Ÿ
Weight without fuel 7,155 lbs
Weight with fuel 11,230 lbs
Ÿ
Ÿ
Ÿ
Ÿ
Ÿ
Ÿ
No open flame for safety and reliability
83% efficiency, 1 million BTU/hour Input
Strobe light shows unit in operation
On board quick-connect manifolds
Three powerful heat exchanger options (See Below)
Self-contained hose reel with electric rewind, clutch, & brake.
Power requirement
2-120VOLTS 20amps
Onboard
thermostat
To Control Your Costs
The Pureheat Heater is a 1 million BTU indirect fired
heater that comes with a trailer unit complete with 1000
ft of hose and four 200,000 BTU heat exchangers. This
type of heater can burn propane, natural gas or diesel.
Each heat exchanger has a fan that is thermostatically
controlled. These units have the advantage of
introducing no moisture or combustion by-products into
the structure, and can be configured many different
ways.
Setup of this unit can be completed in a short time with
no additional equipment. The heat exchangers can be
placed up to 80 ft above grade with no loss of
efficiency.
HX-Series Heat XChangers
MANUFACTURED BY: WACKER NEUSON
Powerful liquid-to-air heat exchangers
Powerful liquid-to-air heat exchangers, available in 3 sizes (50k - 200k), bring
clean, dry heat to your workspace! Simply position HX Heat Xchangers inside
structure and aim where you’d like the heat to go. Finish work is a breeze in a
warm, dry environment and comfortable employees are more productive.
Power requirement
EACH UNIT REQUIRES:
1-120VOLTS 15amps
www.4-way.com
- 3 speed fan
- thermostat
16
Technical Information
Maintenance & Trouble shooting
Building codes require that piping meet certain
standards depending on the application. Pressurized
gas or liquid, natural gas, potable water and
underground drainage pipes are made of different
materials. Note that local laws may require that only
licensed contractors work on gas lines. Before
undertaking any piping project, check local building
codes and take proper safety precautions.
Pipe threads must make not only a mechanical join, but
also a leak proof hydraulic seal. This is accomplished by
the tapered thread of the male matching the tapered
form of the female thread and the use of pipe sealant to
fill any voids between the two threads that could cause a
spiral leak.
When joining NPT tapered pipe to make a leak proof
seal, professionals recommend using a sealer such as
pipe thread tape, more commonly known as Teflon. This
tape should be wound tightly around the male threads
running in the same direction as the lead thread so that
the turning motion of the pipe follows the tape winding
direction.
Manufacturers recommend a specific torque value be
applied to achieve a proper seal, but with NPT fittings a
simple rule of thumb is hand tight, then one to two turns
with a wrench.
The size of a pipe is determined with an I.D.
measurement due to the varying thicknesses of pipe
walls. In this picture both fittings are 3/4" although the
wall thickness is obviously very different.
JIC threads seal on a 37 degree bevel on the mating face of the
fitting. Both the male and female have a flare that is pressed
together by the thread on the fitting. The seat must be clean and
undamaged in order for a proper seal to occur, it should be noted
that the use of thread tape or pipe sealants on this type of fitting will
interfere with proper seating taking place and may result in a leak
occurring.
Fuel gas regulators are used to reduce pressure down to levels
suitable for heaters. There are many different types, but here we
will focus on only what is commonly used in our industry. The 64
and 67c series regulators are usually painted red and reduce gas
pressures from 100 psi (what is normally found in a propane tank)
down to 3 to 10 psi. This unit can also be used as a first stage
regulator, in series with another type of unit for finer adjustment.
The second stage regulator is usually green in color. This
regulator is normally set at 11 inches water column or between 6
and 8 oz of pressure. Another type of regulator is gray in color and
is a two-stage regulator; the second stage still provides 11 inches
of water column at output, but with a higher rate of flow. See the
chart for more details.
780.464.4929
Another method of joining fittings or hose together is with
a JIC or SAE fitting. Natural gas and some propane
fittings use this method. In this picture you can see that a
bevel is present on this type of fitting.
Propane fuel is widely used to provide winter heat in our
industry and there are a few facts that you should know
about using this fuel. Propane is a liquid inside the
cylinder or tank in which it comes. Heaters burn vapor,
not liquid gas.
Therefore, the gas has to turn from liquid to vapor to be
used in a heater. In a typical 100 pound tank the
maximum withdrawal rate of propane at 5 deg Celsius is
around 214,900 Btu per hour, however at –30 deg
Celsius only 107,100 Btu per hour is available or around
half. The layer of frost around a tank will further act as an
insulator and degrade performance even more. This
can be overcome with the use of a vaporizer to increase
available vapor flow.
INCHES OF
KPA
O.Z. WATER
0.431
0.862
1.293
1.724
2.155
2.586
3.648
4.310
1
2
3
4
5
6
8
10
www.4-way.com
1.7
3.5
5.2
6.9
8.7
10.4
13.8
17.3
17
Hydronic heater thaw & cure information. Know your dirt.
Thaw
Excavator's Thaw 18-24" Spacing (Frost Islands)
N/A
Concreter's Thaw 12-18" Spacing (No Frost Islands)
Accelerated Thaw 6" Spacing (Fastest!)
550 sq ft
1,100 sq ft
1,500 sq ft
*1,100 sq ft
*2,200 sq ft
*3,000 sq ft
HHS 1101
HHS 2202
HHS 3002
(3) HHS 3004
+Single PP
+Dual PP
+Dual PP
(1) Booster Pump
Accessories
*3,750 sq ft
Performance will vary depending on hose spacing, thaw type, and insulation.
*Hose Handling System & Pump Pack or Booster Pump & Remote Manifold
Cure
PUREHEAT 1250
Standard: 24" Spacing
Add Accessories* to expand area
*Accessories
HHS 2202
(2) HHS 2202
(2) HHS 3002
+Dual PP
+(2) Dual PP
+(2) Dual PP
(5) HHS 3004
+Booster Pump
(5) Remote Manifold
Coverage will vary depending on hose *Hose
spacing
Handling System & Pump Pack or Booster Pump & Remote Manifold
Insulation Comparison
SIZE
SQ. FOOTAGE
R VALUE
ANNUAL USAGE COST/SQ FT
Reflective R6 Tarp
24’x12'x1/2"
288 sq ft
2 layers = R12
$0.54
Traditional Blankets
25'x6'x1/2"
150 sq ft
2 layers = R5
$1.65
Contractor Benefits:
THAW
CURE
AIR HEAT
RETAIN HEAT
8x faster than air
Accurate initial and final sets
50% fuel savings
Up to 25% faster thaw
Predictable rate
Save finishing labour costs
Dry, clean air heat
Even heat distribution
No enclosure to build
Deliver even heat
No combustion by-products
Cost: 1/6 $$ of hot air
Produce quality concrete
No open flame
Up to 10 feet per application
www.4-way.com
Protect from freezing
Melt frost islands faster
Heat/cure more uniformly
18
Electric Heaters
1500 watt heaters
These heaters are common and can be used in small areas.
120V A/C power is all that’s required. Output is
approximately 5100 BTUs.
4800 watt heater – 220 v (20 amp)
These heaters have a fan and a thermostat, and are a
reliable source of clean dry heat. They are available with
either a stove/dryer plug or can come with bare ends for
wiring directly into a power panel. Each heater will produce
16,000 BTU/hr and may be fitted with a 50ft or 100ft cord on
request. These heaters heat approximately 480 sq. ft. in an
insulated environment.
6 and 9 kW heaters
The Patron E6 and E9 are used in the most demanding of
environments and have proven their abilities in hundreds of
applications. The E6 is a 240V unit and pulls 25 A while the
E9, also a 240V unit, pulls 37.5 A. Both run flawlessly off a
household stove receptacle. Make sure your receptacle is a
NEMA 14-50P configuration to ensure compatibility.
Electric heaters
Maintenance & trouble shooting
These heaters have a fan and a
thermostat, and are a reliable source
of clean dry heat. They are available
with either a stove/dryer plug or can
come with bare ends for wiring directly
into a power panel. Each 4800w
heater will produce 16000 BTU/hr and
may be fitted with a 50 ft or 100 ft cord
on request.
780.464.4929
www.4-way.com
Doesn't work when plugged in? Most
often these heaters are used in
drywalling and can get plugged with
dust. They will seize up and quit
working.
Still doesn't want to work? It may not be
connected to a proper power source.
Check the electrical.
19
Temporary Lighting
6/8kW Light Tower
MANUFACTURED BY: WACKER NEUSON
Trailer-mounted light towers feature a compact, narrow
body design for cost-effective transport and storage. A
30-foot adjustable tower rotates 360-degrees for
optimum lighting flexibility. Quiet operation, the
quietest in its class with sound levels as low as 67
dB(A) at 23 feet, offers maximum versatility for almost
any application.
20kW Light Tower
MANUFACTURED BY: DOOSAN AND MAGNUM
Ideal for mining, oil and gas exploration, and
construction applications, where an electrical power
source isn’t easy to come by. Four 1000-watt lamps
light up to seven acres, while the 20-kW generator
powers tools, heaters, and more. Some units available
in 3-phase power.
Available with Narrow or Wide Body.
Light Balloon
MANUFACTURED BY: WACKER NEUSON
Wacker Neuson's light balloons feature a compact
design providing optimal brightness without glare.
Ideally suited for general job site illumination, road
work, indoor/outdoor illumination of concrete pours
and party rentals. Light balloons feature rugged,
simple construction allowing for use almost anywhere
a reliable light source is needed.
Beacon 360 Led Light
MANUFACTURED BY: LIND EQUIPMENT
The Beacon 360 LED light array comes with a variety of
mounting options. The 4-8 foot tripod can be raised to
bring the light above eye level without sacrificing
illumination. The powerful magnet mount can attach to
structural steel and move easily into place where you
need it. It can also be used upside down, such as
hanging from the ceiling.
www.4-way.com
20
Fuel Services
Maintenance & Trouble Shooting
Transcube 1000L, 2000L & 3000L
MANUFACTURED BY: WESTERN ENVIROMENTAL
Versatile fuel transportation containers
Features
Specs
1000L
Ÿ
Ÿ
Ÿ
Fuel Capacity 1000 liters
Weight without fuel 1,118 lbs
Weight with fuel 2,995 lbs
Ÿ
Ÿ
Ÿ
Ÿ
Ÿ
Ÿ
Ÿ
Ÿ
Ÿ
Transport tanks full with our new fuel stations
100% DOT Compliant
Fuel your own equipment onsite
Choose from 1000, 2000 or 3000 litre tanks
Fully secured with lockable lids
Choose from fuel cells or trailer mounted stations
We'll arrange to have fuel delivered to your site
Available 12v electric pump or hand pump.
Crane and helicopter rated even when full.
2000L
Ÿ
Ÿ
Ÿ
Fuel Capacity 2000 liters
Weight without fuel 1,825 lbs
Weight with fuel 5,574 lbs
3000L
Ÿ
Ÿ
Ÿ
Fuel Capacity 3000 liters
Weight without fuel 2,153 lbs
Weight with fuel 7,765 lbs
Plumb directly
into generators
and heaters!
Fuel management
When heating for extended periods fueling
can become a troublesome issue. If natural
gas is not available then propane, diesel or
electricity are the remaining choices
commonly available. When using propane,
try to set up a regular filling schedule with
your supplier. If diesel is your choice of fuel,
4-Way has various options available,
including our Transcubes. These storage
tanks are double walled, Department
of Transportation (DOT) approved, come
standard with lifting lugs and fork pockets,
and will not spill if tipped over. Transcubes
can be utilized as a trailer mounted mobile
filling station with an electric pump, or
connected directly to heaters to ensure a
long term uninterrupted fuel supply to our
diesel units. And for security, these tanks
can be locked to prevent theft or vandalism.
2000L Transcube
with trailer & pump
780.464.4929
www.4-way.com
21
Sizes available from 2-240kW
Generators
7-13kW Diesel Generators
MANUFACTURED BY: MULTIQUIP, WACKER NEUSON
Compact Portable Generators
Our compact and portable single-phase Generators come fully equipped with
just about every control and convenience feature imaginable.
Specs - 7kw
Weight without fuel 527 lbs
Ÿ
Features - 7kw
Features - 13kw
6.6-gallon fuel tank
Easy to read analog gauges
Multiple power hookups
Can be hooked up to
transcube for extra run time
Ÿ 35-gallon fuel tank for 27
Ÿ
Ÿ
Ÿ
Ÿ
hours of run time
Ÿ Easy to read analog gauges
Ÿ Multiple power hookups
Ÿ Can be hooked up to
transcube for extra run time
20KW Generator - skid/trailer
MANUFACTURED BY: WACKER NEUSON
Compact Mobile Generator
The Wacker G25 is a compact, quiet generator with 1 and 3 phase power and a
number of convenience features to make setup and operation as easy as
possible. A large fuel tank offers excellent runtime.
Features
Specs
Weight without fuel (Skid) 1,911 lbs
Ÿ
Ÿ
Ÿ
Ÿ
Ÿ
58-gallon fuel tank for 32 hours of run time
Easy to read LCD digital gauges
Multiple power hookups
Can be hooked up to transcube for extra run time
38KW Generator
MANUFACTURED BY: WACKER NEUSON
Heavy-duty Mobile Generator
Compact, sound-attenuated generator provides single and three-phase
power for construction, commercial, industrial and special event applications
where quiet, reliable power is needed.
Specs
Ÿ
Weight without fuel 3852 lbs
www.4-way.com
Features
Ÿ
Ÿ
Ÿ
Ÿ
Unit offers low noise for virtually any sound- sensitive application.
Utilizing proven technology and simple design
Trailers are fully equipped and highway ready
Can be hooked up to transcube for extra run time
22
Generators Sizes available from 2-240 kW
80kw Diesel Generator
MANUFACTURED BY: WACKER NEUSON
COMPACT PORTABLE GENERATOR
The G100 is a durable, sound attenuated diesel generator that provides
mobile prime power for larger construction, commercial, industrial, special
event and emergency management applications where quiet, reliable power is
needed.
FEATURES
SPECS
Ÿ
Weight without fuel 4700 lbs
Simple 1-Switch Start
115% Containment
Heavy Duty Trailer Frame
Ÿ2-20 Amp GFI Duplex receptacles and 3-50 Amp Twist Lock
receptacles.
ŸRuntimes:
100% Power - 29.7 hours
75% Power - 36.7 hours
50% Power - 50.1 hours
25% Power - 93.5 hours
ŸHook up to our Transcube for Extended Runtime! (pg 20)
ŸSimple 1-Switch Start
Ÿ115% Containment
ŸHeavy Duty Trailer Frame
130kW & 150kW Diesel Generators
MANUFACTURED BY: DOOSAN, WACKER NEUSON
HIGH POWER MOBILE GENERATORS
These durable, sound attenuated diesel generators provide
mobile prime power for larger construction, commercial, industrial, special
event and emergency management applications where quiet, reliable power is
needed.
SPECS - 130KW
Ÿ
Weight without fuel 6213 lbs
FEATURES - 130KW
Ÿ2-20 Amp GFI Duplex Receptacles and 3-50 Amp Twist Lock
Receptacles
ŸUp to 86 hours run time (25% load)
ŸHook up our Transcube for Extended Runtime! (pg 20)
ŸSimple 1-Switch Start
Ÿ115% Containment
ŸHeavy Duty Trailer Frame
240kW Generator
SOUND ATTENUATED MOBILE GENERATORS
The G290 Tier-3 from Doosan Portable Power is a powerhouse in the industry.
Complete sound attenuation for quieter operation with the well-known John
Deere engine and nearly 24 hours’ worth of on-board fuel. Reliable operation
in temperatures as low as -40°F/°C.
SPECS
Ÿ
Weight (Ready to Run) - lbs (kg): 9678 (4390)
BENEFITS:
780.464.4929
Full diagnostic display
Accessible terminal and lug hookups
24 Hours Onboard Fuel
www.4-way.com
23
Accessories
Fans
Circulate Your Heat With many options from 4-Way!
Ÿ
Ÿ
Ÿ
Ÿ
Ÿ
20 Inch fans - 5,600 CFM (15 Amp Draw)
24 Inch fans - 3,100 CFM (3 Amp Draw)
42 Inch fans - 14,000 CFM (15 Amp Draw)
12 Inch axial fans - 2,000 CFM (15 Amp Draw)
8” Blowers - gas
Ducts
Move Your Heat With many options from 4-Way!
Ÿ Canvas - partially lined and fully lined
Ÿ Low, medium and high temperature polyethylene
Ÿ Vented ducts can distribute hot air throughout closed
work sites and temporary structures.
Tarps
W!
NE
Ÿ Yellow tarps 1/2” - 12x24 R6 insulated
Ÿ Black reflective tarps - 12x25 R6 insulated
Ÿ White fire redardant tarps 1/4” -12x24
Recurculating Air - Save Money!
Both models of the Arctic Bear recirculate air by drawing
warmer in-take air from inside the building rather than the cold
outside air. They do this by running flexible duct work from the
building to the air in-take of the machine. With in-take air
starting at a higher temperature, the cost to raise the air
temperature is reduced as much as 50%, so you can save
up to 30% in fuel savings.
Most job sites are loose - no windows, caulking, insulation etc.
Therefore cold air can infiltrate the building because outside
air is usually at a higher pressure then inside air. High
pressure air will always flow to areas of lower pressure.
When this cold air comes into the building, it causes uneven
temperatures and slows down interior work. The Arctic Bear is
moisture free compared to direct fired heaters. So, the Arctic
Bear allows you to re-circulate inside air but still have a
percentage of outside air (which is pressurized) to be blown
into the building. By using this feature, customers can still
enjoy some fuel savings while pressurizing the building
(keeping cold air from entering the building) to maintain nice
even temperatures.
www.4-way.com
UR
O
T
REN
D
E
T
A
OR
F
R
E
P
S!
T
C
U
D
24
Technical Information
Fuel Consumption for Direct / Indirect Fired Heaters
E
Heater Model
Propane
12,000 BTU Infrared
35,000 BTU Infrared
125K Radiant Heater
100K Sureflame
400K Sureflame
F
Hourly
Max L / hr.
0.666
1.66
6
6.3
12.6
1MM BTU Sureflame
350K LPG/NG Frostfighter
500K LPG/NG Frostfighter
Diesel
Val6 Infrared Heater
350K Diesel Frostfighter
42
14.3
19
0.85
7.5708
500K Diesel Frostfighter
9.4635
HI 750 Wacker Diesel
20.8197
HI 900 Wacker Diesel
23.0910
100#
2 X 100#
PIG
20#
150
60
18
16
8
120
34
32
16
240
66
64
32
30
12
*
*
*
n/a
n/a
*
2.5
Propane
Propane
Tank
1000 G
100
17.76 hrs on 15 gallon tank
17.5 hrs. on underslung tank
105 hrs. on a Transcube/Fuel Cell
14 hrs. on underslung tank
70 hrs. on a Transcube/Fuel Cell
Natural Gas Max Cu.Ft./hr.
400K Sureflame
385
1MM BTU Sureflame
962
350K LPG/NG Frostfighter
347
500K LPG/NG Frostfighter
446
All units have thermostats which can
be used to reduce fuel consumption
and regulate tempertature - Frostfighters
have remote thermostat capability.
*Not recommended in cool conditions - not enough surface area to supply vapour
Fuel Consumption Chart For Ground Heaters
E
F
Model
E1100 - Diesel
E1100G - Diesel
E1700 - Diesel
E1700G - Diesel
E2200 - Diesel
E2200G - Diesel
E3000 - Diesel
E3000G - Diesel
CH5000 - Diesel
Pureheat - Diesel
- NG
- LPG
Arctic Bear XHD - Diesel
Arctic Bear HD - Diesel
- NG
- LPG
HI 750 - Diesel
HI 750 - Diesel
- NG
- LPG
780.464.4929
Capacity
(in liters)
170
170
424
424
567
567
830
830
946
Full Tank Opt
860 cu. ft./hr
35.5
968
945
770 cu.ft/hr
38.1
892
390
Full load Run Time
l / hr.
Min
3.41
50
5
34
5.41
78
7
60
6.8
83
8.3
68
10.41
79
12
70
14.17
64
23.2
71
23
22
42
43
Max
72
38
140
78
64
85
140
84
100
24 hr.
fuel
56-82
105-120
78-130
130-170
127-163
168-200
141-252
237-284
227-340
557
74
72
312-552
312-528
20.8
23.1
850 cu. ft/hr
31
www.4-way.com
25
Over 4400 Different Tools
To Get The Job Done
The Right Way
www.4-way.com
26
Part of the Cerf Incorporated Group of Companies. TSX:CFL
8430 - 24 Street Edmonton, Edmonton, AB
Rentals / Order Desk: 780.464.4929
General Email: info@4-way.com | sales@4-way.com
(4929)
Download