PCB Relays Single Relays Catalog 1308028-2 Revised 5-2009 Micro Relay K (THT – THR) Features – Small power relay – Limiting continuous current 30 A – Minimal weight – Low noise operation – Wave (THT) and reflow (THR/pin-in-paste) solderable versions – For twin version refer to Double Micro Relay K – For latching (bistable) version refer to Micro Relay K Latching – For surface mounted technology refer to SMD versions Typical Applications – – – – – – – – – – – – – Car alarm Door control Door lock Hazard warning signal Heated front/rear screen Immobilizer Lamps front, rear, fog light Interior lights Seat control Sun roof Turn signal Window lifter Wiper control Please contact Tyco Electronics for relay application support. 86CR1_3Dco1 Design Terminals Conditions – ELV/RoHS/WEEE compliant – THT: sealed type washable – THR: sealed type open vent hole PCB terminals for assembly on printed circuit boards All parametric, environmental and endurance tests are performed according to EIA Standard RS-407-A at standard test conditions unless otherwise noted: 23°C ambient temperature, 20 - 50% RH, 998.9 ±33.9 hPa. Weight Approx. 4 g (0.14 oz.) Nominal Voltage 10 V or 12 V; other nominal voltages available on request For general storage and processing recommendations please refer to our Application Notes and especially to Storage in the “Glossary” page 23 or at http://relays.tycoelectronics.com/ appnotes/ Disclaimer All technical performance data apply to the relay as such, specific conditions of the individual application are not considered. Please always check the suitability of the relay for your intended purpose. We do not assume any responsibility or liability for not complying herewith. We recommend to complete our questionnaire and to request our technical service. Any responsibility for the application of the product remains with the customer only. All specifications are subject to change without notification. All rights of Tyco Electronics are reserved. All specifications subject to change. Consult Tyco Electronics for latest specifications. 111 PCB Relays Single Relays Micro Relay K (THT) Dimensional Drawing Micro Relay K THT 12.0 ± 0.2 7.65 0.4 ± 0.1 9.9 ± 0.2 ± 0.1 0.6 ± 0.1 ± 0.2 ± 0.2 5.8 2.5 ± 0.2 *) A 0.95 2.8 ± 0.3 12.9 ± 0.2 *) Additional tin tops max. 1 mm Tyco86etw_se View of the Terminals (bottom view) 3x 8.5 C +0 .0 5 7.5 1. 1.38 2 0 0.5 B 4 5 3.6 1 0.5 10.2 +0.05 0 3 3.0 2x 1.72 2 5x 5x 0.4 0.3 A B A 0.4 0.3 A C A TE86etw_an1 Remark: Positional tolerances according to DIN EN ISO 5458 112 All specifications subject to change. Consult Tyco Electronics for latest specifications. Catalog 1308028-2 Revised 5-2009 PCB Relays Single Relays Catalog 1308028-2 Revised 5-2009 Micro Relay K (THR) Dimensional Drawing Micro Relay K THR 86R1_DD2_2 Additional tin tops max. 1mm 86R1_DD1_2 View of the Terminals (bottom view) View of the Terminals (stand off dimension) 86R1_VT3 All specifications subject to change. Consult Tyco Electronics for latest specifications. 86R1_VT1 113 PCB Relays Single Relays Catalog 1308028-2 Revised 5-2009 Micro Relay K (THT – THR) Contact Data THT/THR Resistive/ inductive load Changeover contact/ 1 Form C Typical areas of application Contact configuration Circuit symbol (see also Pin assignment) 3 THT Wiper load5) V23086-*1*02-A803 THT/THR Flasher load V23086-C100*-A602 Make contact/ 1 Form A Lamp load V23086-***21-A502 Make contact/ 1 Form A (+) 5 4 Rated voltage Rated current Limiting continuous current 23°C 85°C Contact material Max. switching voltage/power Max. switching current 1) On Off Min. recommended load 4) Voltage drop at 10 A (initial) for NC/NO contacts Mechanical endurance (without load) Electrical endurance at cyclic temperature –40/+23/+85°C and 13.5 V 1) 2) 3) 4) 5) (-) 12 V NC/NO 15 A/20 A NC/NO 20 A 20 A 25 A/30 A 15 A/20 A 30 A 20 A 30 A 20 A 40 A 2)/70 A 3) 30 A 40 A 2)/100 A 3) 30 A Silver based See load limit curve 40 A2) 30 A 1 A at 5 V Resistive load: > 3 x 105 operations 20 A on NO-contact Typ. 30 mV, 300 mV max. > 5 x 106 operations Motor reverse: Wiper 5) Flasher load: blocked: > 1 x 106 operations > 2 x 106 operations > 1 x 105 operations 20 A make/5 A make, up to 3 x 21 W, 25 A generator peak - 20 A turn and hazard signal L = 0.77 mH L = 0.7 mH in sequence Lamp load: > 1 x 105 operations 100 A inrush/ 10 A steady state The values apply to a resistive or inductive load with suitable spark suppression and at maximum 13.5 V for 12 V load voltages. For a load current duration of maximum 3 s for a make/break ratio of 1:10. Corresponds to the peak inrush current on initial actuation (cold filament). See chapter Diagnostics of Relays in our Application Notes page 31 or consult the internet at http://relays.tycoelectronics.com/appnotes/ Avoid using capacitive protection circuits. It will reduce lifetime. Wiper loads always to be tested with original loads. Load Limit Curve 086LLC07 Load limit curve 1 ^ = arc extinguishes during transit time Load limit curve 2 ^ = safe shutdown, no stationary arc 114 All specifications subject to change. Consult Tyco Electronics for latest specifications. PCB Relays Single Relays Catalog 1308028-2 Revised 5-2009 Micro Relay K (THT – THR) Circuit Diagram 1 Changeover contact/1 Form C 1 Make contact/1 Form A 4 4 3 1 5 5 2 1 2 86ets_ab 86etw_ab Coil Data Available for nominal voltages Nominal power consumption of the unsuppressed coil at nominal voltage Test voltage winding/contact Maximum ambient temperature range 1) Operate time at nominal voltage 2) Release time at nominal voltage 2) 1) 2) 10 V / 12 V (other coils on request) 0.55 W 500 VACrms –40 to +105°C Typ. 3 ms Typ. 1.5 ms See also operating voltage range diagram. Measured at nominal voltage without coil suppression unit. Note: A low resistive suppression device in parallel to the relay coil increases the release time and reduces the lifetime caused by increased erosion and/or higher risk of contact tack welding. Operating Voltage Range 086_OVR03 300 Coil voltage in % Unom 250 Umax 200 Does not take into account the temperature rise due to the contact current E = pre-energization 150 Uop (E = Un x 1.12) 100 50 Uop (E = 0 V) 0 -40 -20 0 20 40 60 80 100 120 Ambient temperature in °C All specifications subject to change. Consult Tyco Electronics for latest specifications. 115 PCB Relays Single Relays Catalog 1308028-2 Revised 5-2009 Micro Relay K (THT – THR) Environmental Conditions Temperature range, storage Test Cold storage Dry heat Climatic cycling with condensation THT Thermal change Thermal shock Refer to Storage in the “Glossary” catalog page 23 or http://relays.tycoelectronics.com/appnotes/ Relevant standard Testing as per Dimension Comments IEC 68-2-1 1000 h –40°C IEC 68-2-2 Ba 1000 h 125°C EN ISO 6988 IEC 68-2-14 IEC 68-2-14 Nb Na 20 cycles 35 cycles 100 cycles Storage 8/16 h –40/+125°C –40/+125°C Dwell time 1 h THT THT IEC 68-2-30 IEC 68-2-3 Db, Variant 2 Method Ca 6 cycles 56 days 40°C/55°C/93% 40°C/93% THT THT Vibration resistance IEC 68-2-42 IEC 68-2-43 IEC 68-2-6 (sine pulse form) Shock resistance IEC 68-2-27 (half sine form single pulses) Damp heat cyclic constant Corrosive gas Solderability THT THR IEC 68-2-20 IEC 68-2-58 Ta, Method 1 THT THR IEC 68-2-20 IEC 68-2-58 Tb, Method 1A THT THR IEC 68-2-17 Qc, Method 2 Resistance to soldering heat 10 - 500 Hz 6g 6 ms up to 30 g Hot dip 5 s 215°C 245°C Hot dip 10 s 260°C 260°C 10 days 10 days No change in the switching state > 10 μs No change in the switching state > 10 μs Aging 3 (4 h/155°C) for leaded process (Tm = 183°C) for Pb-free process (Tm = 217°C) with thermal screen Preheating min 130°C Sealing 1 min/70°C Open vent hole Ordering Information Part Numbers (see table below for coil data) Relay Description Part Number V23086-C1021-A502 V23086-C1001-A602 V23086-C1001-A403 V23086-C1002-A403 V23086-C1002-A803 V23086-R1801-A403 V23086-R1802-A403 V23086-R1802-A803 V23086-R1821-A502 116 8-1416000-7 9-1416000-6 0-1393280-6 1-1393280-1 On request 6-1414920-0 5-1414920-9 7-1414967-8 6-1414918-8 Contact Arrangement Contact Material Enclosure Soldering Technology 1 Form A: lamp load 1 Form A: flasher load 1 Form C 1 Form C 1 Form C 1 Form C 1 Form C 1 Form C 1 Form A Silver based Silver based Silver based Silver based Silver based Silver based Silver based Silver based Silver based Sealed Sealed Sealed Sealed Sealed Open vent hole Open vent hole Open vent hole Open vent hole THT THT THT THT THT THR THR THR THR All specifications subject to change. Consult Tyco Electronics for latest specifications. PCB Relays Single Relays Catalog 1308028-2 Revised 5-2009 Micro Relay K (THT – THR) Coil Versions Coil Data for Micro K – THT/THR V23086-**001-**** V23086-**002-**** V23086-**021-**** V23086-**801-**** V23086-**802-**** V23086-**821-**** 1) 2) Rated Coil Voltage (V) Coil Resistance ±10% (Ω) Must Operate Voltage (V) Must Release Voltage (V) 12 254 181 181 254 181 181 6.9 5.7 6.9 6.9 5.7 6.9 1.5 1.25 1.5 1.5 1.25 1.5 2) 10 2) 10 12 10 10 Allowable Overdrive 1) Voltage (V) at 23°C at 105°C 27 22 22 27 22 22 18 15 15 18 15 15 Allowable overdrive is stated with no load applied and minimum coil resistance. See operating voltage range. Standard Delivery Packs (orders in multiples of delivery pack) Micro K – THT/THR: 2000 pieces All specifications subject to change. Consult Tyco Electronics for latest specifications. 117