SIRIUS Infeed System. Convincing advantages of screw and spring-loaded terminals sirius Flexible and in line with every requirement: SIRIUS Infeed System Whether screw or spring-loaded terminals, whether circuit-breaker, load feeder or other components: Our SIRIUS infeed system acts as a real all-rounder. Groups of several circuit-breakers (motor starter protectors) – or complete load feeders – can be simply combined and integrated. When it comes to spring-loaded terminals, our modular SIRIUS system includes products, size S00 up to 5.5 kW at 400 V AC. If you prefer controls with classic screw terminals, then circuit-breakers and contactors, sizes S00 and S0 can be used. The SIRIUS infeed system can be used for all motor feeders up to 11 kW. Relays, miniature circuit-breakers or other components can be integrated. This forms the optimum basis for a unified and user-friendly power infeed and distribution system. Brilliant Concept: Design and components 1 3b 3a 7 2 4 7 NSB0_01415a COMPONENTS 5 6 1 3-phase busbars with infeed A 3-phase busbar with infeed is required to connect the power. This comprises an infeed module including two slots for each circuitbreaker as well as an end cover. Depending on the version, the power is either fed in from the left or right through spring-loaded terminals. The spring-loaded terminals allow cables to be connected using conductors 2 with cross-sections of up to 25 mm equipped with connector sleeves. 2 3-phase busbars extend the system The 3-phase busbars to extend the system comprise modules with either two or three slots. The system can be extended as required up to a current carrying capacity of 80 A. An extension plug is supplied with each module. 3a Expansion connector The 3RV19 17-5BA00 extension plug is used to electrically connect adjacent 3-phase busbars. This means that current carrying capacities of up to 63 A are covered. An extension plug is included with every 3-phase busbar. This means that additional extension plugs are only required as spare parts. 3b Wider extension plug Just like the conventional solution, the wider 3RV19 17-5E extension plug also reliably establishes the electrical connection between two 3-phase busbars. The electrical characteristics, for instance, the maximum current rating of 63 A, are identical. What's the difference? When using the wider extension plug, a clearance of 10 mm remains between the connected busbars – thus creating a wiring duct. This can be used to route the control wiring. Typical structure for load feeders using spring-loaded terminals, size S00: 1 3-phase busbar with infeed at the left, 3RV19 17-1A 2 3-phase busbar to extend the system, 3RV19 17-4B 3a Extension plug, 3RV19 17-5BA00 3b Wider extension plug, 3RV19 17-5E 4 End cover, 3RV19 17-6A 5 Connecting plug, 3RV19 17-5AA00 6 Contactor socket, 3RV19 17-7AA00 7 Terminal block, 3RV19 17-5D The connections to the circuit-breaker and contactor can therefore be made from below so that a cable duct above the system is not necessary. 4 End cover The end cover is used to cover the 3-phase busbars at the open end of the system. This prevents voltage arcing to the control cabinet and this is the reason that only one end cover is required for each system. Every 3-phase busbar with infeed includes an suitable end cover so that additional end covers are only required as spare part. 5 Connecting plug The connecting plug is used to establish the electrical connection between the 3-phase busbars and the circuit-breaker. There are three versions available: • For 3RV circuit-breakers, size S00, screw terminals, 3RV19 17-5CA00 • For 3RV circuit-breakers, size S0, screw terminals, 3RV19 17-5AA00 • For 3RV circuit-breakers, size S00, spring-loaded terminals, 3RV19 17-5AA00 6 Contactor socket Load feeders can be reliably configured in this system using contactor sockets. They are suitable for contactors size S00 with springloaded terminals and are simply plugged onto the 3-phase busbars. Direct and reversing starters can be configured. Just one contactor socket is required for direct starters and two contactor sockets for reversing starters. The systems can be flexibly arranged when configuring reversing feeders: either below one another (width: 45 mm) or next to one another (width: 90 mm); whereby in this case it is only possible to mechanically interlock the contactors. Generally, the infeed system is designed for mounting on a 35 mm mounting rail with a depth of 7.5 mm. The mounting rails guarantee the required stability. When using mounting rails with a depth of 15 mm, then the distance piece located on the contactor socket should be removed and located on the mating piece. The distance piece can be removed when using mounting rails with a depth of 7.5 mm. Compensating the depth at the contactor socket As an alternative to using a contactor socket, for direct load feeders, size S00 with springloaded terminals, link modules can be used to establish the connection between the circuit-breaker and contactor. These types of combined load feeders can then be directly snapped onto the slots of the 3-phase busbars. Feeders, sizes S00 and S0, are generally implemented with these link modules. 7 Terminal blocks and mounting rails Using the terminal block, not only can SIRIUS circuit-breakers be integrated but also 1-, 2or 3-pole components. For instance a SIRIUS relay or miniature circuit-breaker. In this case, the terminal block is located in the slot of the extension plug or in the end cover. This means that an outlet can be provided in the center or at the end of the infeed system. The terminal block can be rotated through 180° and can then be interlocked with the appropriate carrier module. Terminal block We also provide a 45 mm mounting rail to simply integrate all 1-, 2- or 3-phase components in the infeed system. This mounting rail is simply screwed onto the carrier module. Mounting rail Line-orientated structure: circuit-breaker and contactor are mounted separately from one another. Mounting option, wiring duct Feeder-orientated structure: circuit-breaker and contactor are mounted as a single unit Configuring reversing feeders Reversing feeder, size S00, 90 mm wide Reversing feeder, size S00, 45 mm wide Versions with terminal block The terminal block is located at the end of the system. The cover is required in order to avoid arcing. The terminal block is integrated in the slot for the extension plug in the middle of the system. The cover cap has been removed, the busbars are jumpered using the lyre-shaped contacts of the terminal block. Wiring duct between the modules. Using the wider extension plug, a cable duct of 10 mm can be formed between the modules. The circuit-breakers and contactors can be connected from below so that a cable duct above the system is not necessary. DESIGN VERSIONS Line- and feeder-orientated structure DESIGN VERSIONS Order quality: Selection and Ordering Data Standard components Version For circuit-breakers size Order No. 3-phase busbars with infeed 3-phase busbars with infeed, left incl. end cover 3RV19 17-6A For 2 switches S00 (spring-loaded terminals) 1) 3RV19 17-1A S00, S0 (screw terminals) 3-phase busbars with infeed, right incl. end cover 3RV19 17-6A For 2 switches S00 (spring-loaded terminals) 1) 3RV19 17-1E S00, S0 (screw terminals) 3-phase busbars to expand the system 3-phase busbars incl. 3RV19 17-5BA00 For 2 switches S00 (spring-loaded terminals) 1) 3RV19 17-4A S00, S0 (screw terminals) extension plug For 3 switches S00 (spring-loaded terminals) 1) 3RV19 17-4B S00, S0 (screw terminals) Connecting plug Connecting plug to establish contact with the circuit-breaker Accessories Order No. Single-unit package S00 (spring-loaded terminals) 1) 3RV19 17-5AA00 S00, S0 (screw terminals) NEW! 3RV19 17-5CA00 S0 (screw terminals) 3RV19 27-5AA00 Multi-unit package S00 (spring-loaded terminals) 1) 3RV19 17-5A S00, S0 (screw terminals) NEW! 3RV19 17-5C S0 (screw terminals) 3RV19 27-5A Spare parts Contactor socket End cover 2) Contactor socket to configure direct or reversing starters Multi-unit package Single-unit package S00 (spring-loaded terminals) 3RV19 17-7AA00 Multi-unit package S00 (spring-loaded terminals) 3RV19 17-7A Order No. 3RV19 17-6A Extension plug3) Single-unit package 3RV19 17-5BA00 Terminal block Terminal block to integrate 1-/2-/3-pole components NEW! Single-unit package 3RV19 17-5D Mounting rail 45 mm mounting rail to mount on 3RV19 17-1A/1E and 3RV19 17-4A NEW! Single-unit package 3RV19 17-7B Wider extension plug To open the spring-loaded infeed terminal 3RV19 17-1 Length: approx. 175 mm Blade dimensions: 5.5 x 0.8 mm 8WA2 806 To open spring-loaded terminals for SIRIUS circuit-breakers and contactors Length: approx. 170 mm Blade dimensions: 3.5 x 0.5 mm 8WA2 803 1) Compatible to the following circuit-breakers: 3RV10 11-…2. (size S00, spring-loaded terminals from product version E03) NEW! Single-unit package Tool 3RV19 17-5E 2) For 3-phase busbars with infeed 3RV19 17-1., the end cover is already included 3) For 3-phase busbars, the extension plug is already included to expand the system 3RV19 17-4 4 |7 Design highlights • New degree of flexibility when configuring and System-orientated and modular: the features extending the system • Integration of motor feeders with screw and springloaded terminals possible • Maximum current rating of 63 A • Additional 1-, 2- or 3-pole components can be additionally integrated using the terminal block • Either infeed from the left or right up to conductor 2 cross-sections of 25 mm • Mounting time savings by using simple plug-in connections • More free space in the control cabinet as a result of the extremely compact design • High vibration strength, especially for controls with spring-loaded terminals • Optional wiring duct between feeders A basis module forms the foundation of the system. This includes a 3-phase busbar with the appropriate infeed. Depending on the version, the infeed with spring-loaded terminal is mounted either at the left or right. This means 2 that a conductor cross-section of 25 mm can be used to connect power to the system. The basis module always has two slots to integrate a circuit-breaker. A connector is used to establish the electrical connection between the 3-phase busbars and the circuit-breakers. Extension modules in the form of 3-phase busbars are available to expand the system. The individual modules are connected to one another through an extension plug. The complete system can be snapped onto 35 mm mounting rails according to DIN EN 50022 and can be expanded as required up to a maximum current rating of 63 A. It is especially easy to configure the system and without any additional costs thanks to the straightforward plug-in mounting system. The lateral system infeed reduces the amount of space in the cabinet. The additional height of the infeed system is then only 30 mm. The fact that it is possible to feed-in power at both sides means the highest degree of flexibility when engineering the system. Whether an infeed at the left and outfeed to the right, whether a ring infeed or if additional loads are to be supplied: You have unlimited possibilities. And last but not least, the terminal block and the wide extension plug allow additional design versions. 2| 3 © Siemens AG 2007 SIRIUS Solid-state switching devices Name Street, Postal Code/City Telephone/Fax E-mail | SIRIUS Soft starter SIMATIC ET 200pro SIRIUS Motor management system SIMOCODE pro Printed in Germany SIRIUS Engineering load feeders SIRIUS Motor starter SIRIUS Relays SIRIUS Safety Relays SIRIUS Pushbuttons and indicator lights SIRIUS Signaling columns and integrated signal lamps SIRIUS Cable-operated switches SIVENT Fans SIDAC Reactors & filters SIDAC & SIVENT Solutions Motor starter ES SIMOCODE ES Soft starter ES SIRIUS Safety Integrated AS-Interface ECOFAST SIRIUS Modular system Siemens AG 3 Automation and Drives Low-Voltage Controls and Distribution P.O. Box 48 48, 90327 NUREMBERG, GERMANY www.siemens.com/lowvoltage/technical-assistance www.siemens.com/sirius SIRIUS Connection systems The information provided in this brochure contains merely general descriptions or characteristics of performance which in case of actual use do not always apply as described or which may change as a result of further development of the products. An obligation to provide the respective characteristics shall only exist if expressly agreed in the terms of contract. All product designations may be trademarks or product names of Siemens AG or supplier companies whose use by third parties for their own purposes could violate the rights of the owners. | DISPO 27601 SIRIUS Position switches | 2105C6191 SGSR.52.7.04 PA 03072.5 | SIRIUS Infeed system Subject to change without prior notice 11/05 | Order No. E20001-A690-P302-V1-7600 Company/Department COMMANDING DETECTING AND SIGNALING Please send the selected information to the following address: ENGINEERING SUPPLYING Always up-to-date: Our regular Newsletter gives you current information about industrial controls and power distribution. Simply register under www.siemens.com/lowvoltage/ newsletter SIRIUS AND MORE Newsletter MONITORING STARTING AND CONTROLLING PROTECTING SIRIUS Industrial Controls SWITCHING Ordering by fax +49/911/978-3321 CD/Z1246