FLAT THIN THIN PROFILE PROFILE CENTRIFUGAL CENTRIFUGAL FAN FAN COIL COIL UNIT UNIT FLAT Thin profile centrifugal fan coil unit FLAT series Simple, attractive design with thin thikness. 30 basic models, differing sizes and versions. Floor-standing, suspended, built-in, ceiling- mounted, suspended-ceiling installation, ductable. With bottom or front air intake and top or front air outlet. For 2 or 4-pipe systems, with 3 or 4-row exchangers. Cased units with airflow direction louvers. Decorative panels in lacquered wood or painted sheet metal. design 157 m m 360° INDOOR CLIMATE SOLUTIONS Strutture Electric fans In galvanised, insulated sheet metal. Con- Single-phase asynchronous motor with 6 speed densate-drain pan in galvanised, insulated settings (3 connected in the factory) with over- sheet metal with fittings for condensate drai- load cutout. Anti-vibration mountings for low- nage. Knock-outs on side panels for easy noise operation. factory or site fitting of accessories. Slots on Three-dimensional double-inlet centrifugal fans rear of pane to facilitate wall-mounting. with aluminium impellers. Statically and dynamically balanced. All fans are run tested during final on-line test and inspection procedures. Heat exchangers ultrasottile Consist of Aluminium fins mechanically expanded onto copper tubes in a continuous block. Frame in galvanised steel, brass headers with female 3/4” gas fitting. Air vents on both headers. Standard water connections on left-hand side; right-hand side on request. Coil can be easily rotated if necessary. Air filters Metal frame containing honeycomb polypropylene filter media. Easy to remove and clean. Standard filters are to EU1 efficiency;other efficiencies available on request. Cabinet Hot-galvanised sheet metal pre-coated with a PVC film to increase resistance to corrosion. Airflow direction louvres in ABS or nylon. Colour of housing: white. Colour of louvres: light grey. Other RAL colours available on request. www.eden-clima.com FLAT Decorative panels For vertical wall recessed type and horizontal ceiling concealed type, decorative panels in white lacquered wood or white PVC-coated galvanised metal are available. The panels come complete with air intake and outlet grilles and filter. Accessories • Electric heaters • 2 or 3- way valves • On-off and balancing valves • External air intake dampers (manual or motor-operated) • Inlet and discharge plenums • Auxiliary coils • Condensate drain pans • Telescopic extensions • Plinths • Decorative panels • Condensate drain pump • etc. Controls Terminal strip applied to the side of the fan coil for connection to the wall-mounted controller. Manual, semi-automatic and automatic controls, with display and infrared remote control on request. 360° INDOOR R CLIMATE SOLUTIONS 000 001 002 n° 2 2 2 Ø 1/2” 1/2” 1/2” kg 16 19 21,5 Ø 1/2” 1/2” 1/2” kg 17 20 23 L mm 960 1160 1360 M mm 742 942 1142 C mm 712 912 1112 Fans 2 rows coil Fittings Net weight (2 rows) 3 rows coil Fittings Net weight (3 ranghi) External dimensions GENERAL DIMENSIONS 233 460 25 Ø 20 130 120 L M C 480 25 152 157 www.eden-clima.com FLAT 000 001 002 2 pipe system (3R coil) - The values marked with min, med and max refer to the 3 standard speeds set in the factory Total cooling capacity W max 1890 2270 2660 W med 1510 2020 2190 W min 1160 1470 1730 W max 1460 1750 2020 Sensible cooling capacity W med 1140 1540 1640 W min 866 1100 1290 Water flow l/h max 326 391 458 Water pressure drop kPa max 13,3 7,24 11,3 W max 2410 2930 3350 W med 1900 2570 2720 W min 1430 1820 2120 l/h max 4100 4940 5680 kPa max 3220 4360 4590 W max 2410 3080 3560 W med 343 407 453 W min 254 347 353 Water flow l/h max 182 232 265 Water pressure drop kPa max 51,6 51,8 54,3 m3/h max 43,1 45,5 48,8 m3/h med 35,5 37,8 40,6 Heating capacity Water flow Water pressure drop Heating capacity Air flow 40 38 64 db(A) max 0,18 0,17 0,32 db(A) med 41 41 61 db(A) min 33 37 53 m /h 3 Sound power level - min Power input W max 30 30 273 Absorbet current A max 018 025 125 Standard unit with free outlet: external static pressure = 0 Pa Sound power level: ISO 23741 Sound pressure level: 8,6 dB(A) lower that the sound power level for a room of 90 m3 with a reverberation time of 0,5 sec. Supported power supply: ~230V±10% / 1ph / 50-60Hz COOLING Inlet water temp.: 7°C Outlet water temp.: 12°C Inlet air temp.: 27°C d.b. - 19°C w.b. 360° INDOOR CLIMATE SOLUTIONS HEATING Air temp.: 20°C Inlet water temp.: 50°C HEATING Air temp.: 20°C Inlet water temp.: 70/60°C 000 001 002 2 pipe system (2R coil) - The values marked with min, med and max refer to the 3 standard speeds set in the factory Total cooling capacity W max 1450 1850 2240 W med 1200 1600 1920 W min 959 1270 1500 W max 1180 1460 1740 Sensible cooling capacity W med 956 1250 1470 W min 751 972 1130 Water flow l/h max 249 319 386 Water pressure drop kPa max 5,45 10,3 17,1 W max 1960 2430 2910 Heating capacity W med 1610 2090 2450 W min 1250 1610 1870 Water flow l/h max 3380 4,15 4960 Water pressure drop kPa max 2770 3570 4170 W max 2150 2750 3170 W med 351 415 477 W min 264 335 382 Water flow l/h max 192 241 272 Water pressure drop kPa max 54,9 53,6 55 m /h max 48,3 47,4 49,3 m3/h med 41,8 38 37,6 40 38 64 db(A) max 0,18 0,17 0,32 db(A) med 41 41 61 db(A) min Heating capacity 3 Air flow m /h 3 Sound power level - min 33 37 53 Power input W max 30 30 273 Absorbet current A max 018 025 125 Standard unit with free outlet: external static pressure = 0 Pa Sound power level: ISO 23741 Sound pressure level: 8,6 dB(A) lower that the sound power level for a room of 90 m3 with a reverberation time of 0,5 sec. Supported power supply: ~230V±10% / 1ph / 50-60Hz 000 001 002 4 pipe system (1R coil data) - The values marked with min, med and max refer to the 3 standard speeds set in the factory W max 2470 2620 3530 W med 1990 2350 2940 W min 1560 1780 2370 Water flow l/h max 343 407 453 Water pressure drop kPa max 254 347 353 m /h max 182 232 265 m /h med 51,6 51,8 54,3 m3/h min 43,1 45,5 48,8 db(A) max 35,5 37,8 40,6 db(A) med 41 41 61 db(A) min 33 37 53 Heating capacity 3 Air flow Sound power level - 3 Standard unit with free outlet: external static pressure = 0 Pa Sound power level: ISO 23741 Sound pressure level: 8,6 dB(A) lower that the sound power level for a room of 90 m3 with a reverberation time of 0,5 sec. Supported power supply: ~230V±10% / 1ph / 50-60Hz COOLING Inlet water temp.: 7°C Outlet water temp.: 12°C Inlet air temp.: 27°C d.b. - 19°C w.b. HEATING Air temp.: 20°C Inlet water temp.: 50°C HEATING Air temp.: 20°C Inlet water temp.: 70/60°C www.eden-clima.com DP FLAT 2013-0 GB A GROUP S.p.A. - Via Montegrappa, 67 - 31020 San Zenone degli Ezzelini (Treviso) - Italy Tel. +39 0423 567774 - Fax +39 0423 567985 - www.aliseogroup.com - info@agroup-it.com