DS10000IBFS Ultra-stable, high precision (ppm class) fluxgate technology DS Series current transducer for non-intrusive, isolated DC and AC current measurement up to 11000A Features Applications: Linearity error maximum 1 ppm MPS for particles accelerators 4mm banana jack for secondary current Stable power supplies Transducer core optimized for high level of immunity against external magnetic fields Precision drives Batteries testing and evaluation systems Operating temperature Power measurement and power analysis Transducer head 0-70°C Current calibration purposes Electronics 0-45°C Turns ratio 1:2500 Aperture diameter 140 mm 2U 19” Control unit with AC 115V/230V mains supply Danisense advanced sensor protection circuit “ASPC” Specification highlights Symbol Unit Nominal primary AC current IP N A C A rms 7000 Nominal primary DC current IP N DC A 10000 ÎPM A 11000 Measuring range Primary / secondary ratio Min Typ. Max 1:2500 1:2500 Linearity error ƐL ppm -1 1 Offset current (including earth field) IOE ppm -5 5 accƐ ppm -6 6 AC Maximum gain error 10Hz to 1kHz ƐG % Operating temperature range Ta °C DC Overall accuracy @25°C (= ƐL + IOE) n1: n2 All ppm (or %) values refer to nominal current page 1 - 2016-09-07 Precision – Innovation www.danisense.com ±0.05 0 70 DS10000IBFS Electrical specifications at Ta=23°C Parameter Symbol Unit Min Typ. Max Nominal primary AC current IPN AC A rms 7000 Nominal primary DC current Comment Refer to fig. 1 & 2 for derating IPN DC A 10000 Refer to fig. 1 for derating Measuring range IPM A 11000 Refer to fig. 1 & 2 for derating Overload capacity ÎOL kA 20 Nominal secondary current ISN mA Measuring resistance RM Ω Linearity error ƐL ppm -4000 4000 1:2500 1:2500 0 1 µA /K -1 -4 -5 -20 -0.1 -0.4 1 4 5 20 0.1 0.4 f(-3dB ) kHz 100 ƐG % q º tr @ 90% µs Primary / secondary ratio Offset current (including earth field) Offset temperature coefficient Bandwidth Amplitude error Phase shift IOE TCIOE 10Hz –1kHz 1kHz -5kHz 5kHz - 30kHz 10Hz –1kHz 1kHz -5kHz 5kHz - 30kHz Response time to a step current IP N Noise 0 - 100Hz 0 - 1kHz 0 - 10kHz 0 - 100kHz Fluxgate excitation frequency µA ppm µA ppm/K no ise ppm rms f E xc kHz Non-measured, 100ms At nominal primary DC current Refer to fig. 1 for details ppm refers to nominal current µA refers to secondary current ppm refers to nominal current µA refers to secondary current ppm refers to nominal current µA refers to secondary current Small signal, graphs figure 3 0.05% 1.50% % refers to nominal current 15.00% 0.05º 0.5º 3º 1 di/dt = 100A/µs 0.05 0.40 3.00 4.00 Measured on secondary current 7.82 Induced rms voltage on primary conductor µV rms Mains input voltage AC VA C 90 295 Mains input voltage DC VDC 127 417 Control Unit ambient temperature °C 0 45 Transducer head temperature °C 0 70 Offset stability over time ppm / mo nth -0.1 -0.28 0.1 0.28 Offset change with vertical external magnetic field µA /mT 8 Offset change with horizontal external magnetic field µA /mT 8 10 50/60 Hz Refer to fig. 1 for derating Stability page 2 - 2016-09-07 Precision – Innovation www.danisense.com ppm refers to nominal current µA refers to secondary current (perpendicular to bus bar) µA refers to secondary current (parallel to bus bar) µA refers to secondary current DS10000IBFS Measurement resistor RM and ambient temperature derating (Fig. 1) Cable length 5m Maximum measurement resistor Value (Ohm) Maximum measurement resistor vs. ambient temperatures 5 4 3 2 1 0 7000 7500 8000 8500 9000 9500 10000 10500 11000 Primary Current, DC or peak (A) R_max_25 R_max_45 R_max_70 Frequency and ambient temperature derating (Fig. 2) Maximum primary current A rms Primary Current (A) 10000 1000 100 10 1 10Hz 100Hz 1,000Hz 10,000Hz 100,000Hz 1,000,000Hz Primary Current (Hz) Max current (Arms) 65 deg Max current (Arms) 45 deg Max current (Arms) 25 deg Frequency characteristics (Fig. 3) Amplitude / Phase 10.00 5.00 0.00 -5.00 -10.00 10Hz 100Hz 1,000Hz Amplitude (%) page 3 - 2016-09-07 Phase Error (deg) Precision – Innovation www.danisense.com 10,000Hz DS10000IBFS Isolation specifications Parameter Unit Value Rated isolation voltage rms, reinforced isolation IEC 61010-1 standard and with following conditions 3 - Overvoltage category III -Pollution degree 2 kV Rms voltage for AC isolation test, 50/60 Hz, 1 min - Between primary and (secondary and shield) - Between secondary and shield kV Impulse withstand voltage kV 43.5 Creepage distance / Clearance mm 60 / 60 Comparative Tracking Index CTI 600 23.7 0.2 Absolute maximum ratings Parameter Unit Max Comment Primary current kA 20 Maximum 100ms Primary current kA 11 Continous Environmental and mechanical characteristics Parameter Unit Min Typ Max Comment Ambient operating temperature range °C 0 45 Control unit Ambient operating temperature range °C 0 70 Transducer head Storage temperature range °C -40 85 Relative humidity % 20 80 Mass kg Connections Standards page 4 - 2016-09-07 19 6 Non-condensing Transducer Head Control Unit 4mm banana Jacks EN 61326-1 EMC EN 61010-1:2010 Safety Precision – Innovation www.danisense.com DS10000IBFS Advanced Sensor Protection Circuits “ASPC” Developed to protect the current transducer from typical fault conditions: Unit is un-powered and secondary circuit is open or closed Unit is powered and secondary circuit is open or interrupted Both DC and AC primary current up to 100% of nominal value can be applied to the current transducers in the above situations without damage to the electronics. Please notice that the sensor core can be magnetized in all above cases, leading to a small change in output offset current (less than 10ppm) page 5 - 2016-09-07 Precision – Innovation www.danisense.com DS10000IBFS DS10000 Transducer Head Dimensions 140mm page 6 - 2016-09-07 Precision – Innovation www.danisense.com